IPG 光纤激光器维护手册
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Page 1 of 9
Form: 44511 Maintenance routine
English Revision: 02
Ytterbium Fiber Laser
Maintenance routine
English
1. Usage of this guide
This document provides you an overview about the requested maintenance and service of the Laser system at customer side.
Please read the following instructions carefully and handle also to keep the laser and its components in immaculate conditions.
2. Maintenance tasks once a week
Checking water level (DI-Water- and Tapwater level-Indication)
Estimated
work time
15 minutes including water refilling
Time interval Once a week
Description Please check the water level (see the seperate waterlevel-
indications) of the DI-Water- and Tapwater-Tank at chiller side.
If it is necessary please refill water.
For cooling external optics use DI-water only.
Checking air filter at chiller side
Estimated work time 5 minutes visual control
30 minutes for filter exchange
Time interval Once a week
Description Please check the status and the level of pollution of the air fil-ters at chiller side. A high degree of pollution reduces the air
flowrate and also the cooling efficiency of the chiller.
Take care that the cooling rib area of the chiller are completely
covered by the new filter plane.
3. Maintenance tasks by the quarter
Checking water qualitiy
15 minutes
Estimated
work time
Time interval quarterly
Description Please check the water quality of both cooling circuits (DI- and
Tab water).
If you observe any sediments (e.g. algas) in the water tank
then deflate the tanks and the water pipes by the provided wa-
ter output nozzles. If it is necessary please clean up the tanks
and the relevant water pipes. In case of a complete water ex-
change please also clean up the water input filter at laser side.
In consultation with IPG Laser GmbH you are able to add addi-
tives only into tab water to prevent algal formation.
At DI-water no algal formation should be observed because of
the low water conductance at DI-water-circuit.
DO NOT ADD ANY ADDITIVES INTO DI-WATER-TANK.
Refill the Tab water-/DI-Water tank up to the maximum level.
Dirt and dust on laser and external optic cabinets
15 minutes visual control
Estimated
work time
Time interval Quarterly
Description The laser and the external optic cabinets were constructed as
dustfree devices. If you observe any dust or dirt on it please
check the function of the cabinets ventilation and their airfilters.
Missed or misapllied airfilters need to be replaced or repaired. I
If it is required please remove any dirt or dust by using of a
damply and not wetly cleanly tissue.