DP73奥林巴斯

合集下载

奥林巴斯生物显微镜鉴定成像与挑选系统

奥林巴斯生物显微镜鉴定成像与挑选系统

奥林巴斯生物显微镜鉴定成像与挑选系统技术指标如下:OLYMPUS生物显微镜BX51超宽视野观察筒,4\10\20\40\60倍为干镜,500万成像系统1 显微镜镜体BX51TF Micrscope frame for transmitted microscopy with built-infilter holders for four filters(LBD, ND6, ND25, an openposition for an optional filter of 45mm dia.), includinghexagonal driver AB8804, immersion oil 8cc and shieldsticker AD4908(2pcs.)Corresponded to WEEE and RoHSregulations1超宽视野三目镜筒U-SWTR-3 Super widefield trinocular tube 1 六孔物镜转盘U-D6RE Sextuple revolving nosepiece with a slot for analyzer orDICslider1机械式载物台U-SVRB-4 Ceramic surface mechanical stage with right-hand lowdrivecontrol(long type)1夹片器U-HLDT-4 Specimen holder for BX stage, left hand, for two specimens,thick type1摆动式聚光镜U-SC3 Swing-out condenser N.A. 0.9-0.16 1 100W卤素灯灯室U-LH100-3 Lamp house for 100W halogen with connecting cableCorresponded to RoHS, WEEE regulations112V100W灯泡JC12V100WHAL-L Halogen bulb(Philips No. 7724) 2 电源线UYCP Power cord 1 防尘罩COVER-018 Dust cover Type 018 for BX2(L 510mm x W 320mm x H 530mm)1万能平场半复消色差物镜UPLFLN4X U plan semi apochromat objective 4X/0.13, WD 17 1UPLFLN10X2 U Plan Semi Apochromat objective 10X/0.3, WD 10 1 UPLFLN20X U plan semi apochromat objective 20X/0.5, WD 2.1(spring) 1UPLFLN40X U plan semi apochromat objective 40X/0.75, WD 0.51(spring)1UPLFLN60X U plan semi apochromat objective 60X/0.9 WD 0.2 withcorrection collar(spring, c.c. 0.11-0.23)1超宽视野目镜SWH10X-H Super widefield eyepiece 10X(focusable) 2 目镜测微尺U-OCMC10/100X Cross lines and 10mm/100 on X 1DP25 500万像素成像系统 1 C型视频接口U-TV0.63XC C-mount camera attachment with 0.63X lens 1 数码相机主机DP25 Digital camera for microscope with 5M pixel CCD, includingIEEE1394a connection cable, IEEE1394a PCI board andCD-ROM1图象软件DP2-BSW-E-V2.2 CD-ROM Application softwareforDP20/DP25/DP70/DP71/DP721电脑HP 1二SZX16 最大放大倍数230倍,落透两用光源 1 显微镜镜体SZX2-ZB16 16:1 zoom microscope body with aperture diaphragm 1三目镜筒SZX2-TR30 30 degrees inclined trinocular observation tube 1粗微调聚焦装置SZX2-FOF Fine and coarse focusing unit 1 超薄多功能透射光底座SZX2-ILLT Thin type LED transmitted illuminator, world voltage 1 电源线UYCP Power cord 1 电源线U-ACAD4515 Power cord for U-CFU, MM6-CFU, BXFM-A,SZX-FOA2/SZX2-FOA, SZX2-ILLT1高分辨率平场复消色差物镜SDFPLAPO1XPF Distortion free plan apochromatparfocal objective 1X(W.D.60mm)1SDFPLAPO2XPFC Distortion free plan apochromatparfocal objective 2X(W.D.20mm)with correction collar1目镜WHN10X-H Widefield eyepiece 10X, focusable 2 SZX16双物镜转换器SZX2-2RE16 Double revolving nosepiece for SZX16 1双分支互锁导光管光纤导管LG-DI Light guide, with bifurcated fiber optics 1 光源LG-PS2 Light source for light guide 1 聚光透镜HLL301 Collector lens 2 滤色片30.5S-G533 Green filter for black and white photography, 30.5mm dia. 1 30.5S-LB80 Light balancing filter, 30.5mm dia. 1 灯泡JCR12V100WB Halogen bulb for LG-PS2(SZX-DI/DFI/R66/ILLC) 2 电源线UYCP Power cord 1。

35mm_奥林巴斯OM-1单反相机

35mm_奥林巴斯OM-1单反相机
镜头朝上,看相机底板(图4)。底板左端是有盖电池 仓,内置1.5V蘑菇形氧化银电池,可使镜内硫化镉测光表通 电而正常工作。底板中央置有三脚架安装螺孔。螺孔右下 方,镀铬面上凸显:MADE IN JAPAN 511389。
1972年,德国科隆摄影器材博览会(PHOTOKINA)发布由日本奥林巴斯公司出 品的35mm M-1单反相机,德国徕兹(LEITZ)公司因此与奥林巴斯公司交涉,说涉 嫌盗用了徕卡M1旁轴相机型号,奥林巴斯公司遂将机型M-1改为OM-1。奥林巴斯 M-1单反相机因产量小而成为二手市场的抢手货。
1973-1974年,日本奥林巴斯公司向市场推出奥林巴斯OM-1单反相机。1974年 推出底板上可安装马达卷片器的OM-1 MD单反相机。1979年推出取景器内有LED闪 光指示灯的OM-1N MD单反相机,它是OM-1 MD的改良机型。以上三种奥林巴斯单
照相机 79
2023.09 / 相机世界
环,环两侧对应位置上有两枚装卸镜头用的锁钮。卸下镜头 时,用两指同时摁下两锁钮,逆时针旋转镜筒至极限位置,然 后从镜座卡口内拔出镜头,露出镜座卡口。镜座卡口内可见自 动复位的45°反光镜以及上方的对焦屏。安装镜头时,必须先 将镜尾镀铬环上的红点对准镜座卡口左侧镀铬面上的红点, 然后插入镜头尾端并顺时针旋转镜筒,直至镜头被锁定在镜 座上。
机顶右端是走片计数窗,计数窗左侧是卷片上弦扳手,扳 手左上方是快门钮。实际操作时,每扳动一次卷片上弦扳手,
计数窗内走片数值即相应进一位,可摁下已上弦快门钮。按此 步骤,计数窗内数值从0开始进位,直至进位至数字36,拍完 整卷胶片。一旦打开后盖,显示窗内数值立刻归零。
快门钮左侧,机顶上装着胶片感光度ASA值设置盘,设置 盘外径21.4mm、 厚5.8mm,圆周上饰有工俊秀丽的镀铬滚 花。设置盘端面周边凸显一圈ASA值。

10种常见易混淆饮片快速检验方法

10种常见易混淆饮片快速检验方法

10种常见易混淆饮片快速检验方法徐岳鑫(宿迁市食品药品检验所,江苏宿迁223800)摘要目的:快速鉴别五加皮等10种常见的易混淆饮片㊂方法:采用性状㊁显微和荧光反应等方法㊂结论:通过颜色,气味和形状的区别,结合显微特征中草酸钙结晶等关键鉴别点,可以快速区分易混淆的饮片㊂结论:通过以上方法可以快速对五加皮等10种易混淆的饮片进行鉴定㊂关键词易混淆饮片;快速检验;性状;显微;荧光中图分类号:R286.0文献标识码:A 文章编号:1672-8351(2020)12-0004-03近年来,随着中药材及饮片专项整治的深入开展,中药材及饮片质量有明显好转㊂根据中检院发布的2019年全国中药材及饮片质量分析报告[1],合格率达到了91%,而2013~2018年分别为64%㊁68%㊁75%㊁77%㊁84%㊁88%,合格率呈现出逐年提升㊁稳步向好的发展态势,不合格饮片仍集中在小部分易混淆品种之中㊂针对近年来我所检出的不合格率较高的10个品种,总结出一套快速检验方法,主要从性状㊁显微和荧光反应入手,即可快速分辨假劣和易混淆药品,现总结如下:1仪器和样品显微镜:日本奥林巴斯B X51显微镜,D P73成像系统㊂样品:本文提及的10种饮片,均为宿迁市食品药品检验所近年省抽检品,经检验后留样㊂2鉴别方法2.1五加皮和香加皮五加皮为五加科植物细柱五加的干燥根皮,香加皮为萝藦科植物杠柳的干燥根皮㊂性状鉴别要点:香加皮有特异香气,而五加皮气微香㊂显微鉴别要点为:五加皮薄壁细胞中含草酸钙簇晶,香加皮薄壁细胞中含草酸钙方晶(见图1㊁图2)㊂二者功效相似,均可利水消肿㊁祛风湿㊁强筋骨,但香加皮有小毒,临床使用剂量小于五加皮,二者混用有中毒风险㊂图1草酸钙簇晶(五加皮)图2草酸钙方晶(香加皮)2.2山药和参薯山药为薯蓣科植物薯蓣的干燥根茎㊂参薯为薯蓣科植物参薯的干燥块茎㊂显微鉴别要点:从外表皮处刮取粉末观察,参薯可见石细胞,而山药无石细胞,只可见木栓细胞㊂图3木栓细胞(山药)图4石细胞(参薯)2.3罗布麻叶和大花罗布麻叶罗布麻叶为夹竹桃科植物罗布麻的干燥叶㊂大花罗布麻叶为夹竹桃科植物大花罗布麻的干燥叶㊂性状鉴别要点:罗布麻叶质脆易破碎,大花罗布麻叶为革质,质坚韧不易破碎㊂显微鉴别要点:大花罗布麻叶每个表皮细胞上有1个乳突,而罗布麻叶无此特征㊂图5表皮细胞(罗布麻叶)图6表皮细胞(大花罗布麻叶)2.4小通草和绣球小通草小通草为旌节花科植物喜马山旌节花㊁中国旌节花或山茱萸科植物青荚叶的干燥茎髓㊂绣球小通草为虎耳草科植物云南绣球的干燥茎髓㊂性状鉴别要点:小通草易折断,绣球小通草不易折断,甚至可绕成小环状而不断㊂显微鉴别要点:小通草可见草酸钙簇晶或无草酸钙结晶,绣球小通草可见草酸钙针晶㊂图7草酸钙簇晶(小通草)图8草酸钙针晶(绣球小通草)2.5麦冬和山麦冬麦冬为百合科植物麦冬的干燥块根㊂山麦冬为百合科植物湖北麦冬或短葶山麦冬的干燥块根,其中湖北麦冬为市场主要流通品种㊂显微鉴别要点:麦冬横切面韧皮部束16~22个,湖北麦冬韧皮部束7~15个(建议在偏光下观察,效果好更容易计数)㊂图9横切面(麦冬)图10横切面(湖北麦冬)2.6延胡索㊁山药零余子和黄独零余子延胡索为罂粟科植物延胡索的干燥块茎㊂山药零余子为薯蓣科植物薯蓣叶腋内生长的珠芽㊂黄独零余子为薯蓣科植物黄独叶腋内生长的珠芽㊂鉴别要点:将断面置紫外光灯365n m波长下观察,其中黄独显黄绿色荧光,延胡索显金黄色荧光,山药无荧光㊂图11左为黄独,中为延胡索,右为山药2.7鸡骨草和毛鸡骨草鸡骨草为豆科植物广州相思子的干燥全草,毛鸡骨草为豆科植物毛相思子的干燥全草㊂性状鉴别要点:鸡骨草叶下表面被短硬伏毛,毛鸡骨草叶下表面密被长柔毛㊂图12 鸡骨草图13 毛鸡骨草2.8 黄柏和关黄柏黄柏为芸香科植物黄皮树的干燥树皮,关黄柏为芸香科植物黄檗的干燥树皮㊂性状鉴别要点:关黄柏外表面偶见灰白色的粗皮残存且有一定弹性,而黄柏无此特征㊂图14 左为关黄柏,右为黄柏2.9 半夏和水半夏半夏为天南星科植物半夏的干燥块茎,水半夏为天南星科植物鞭檐犁头尖的干燥块茎㊂性状鉴别要点:半夏为圆形或类圆形片,水半夏常可见不规则圆锥形片,一端尖,另一端钝圆㊂图15 左为半夏,右为水半夏2.10 木通与川木通木通为木通科植物木通㊁三叶木通(市场主流品种)或白木通的干燥藤茎;川木通为毛茛科植物小木通(市场主流品种)或绣球藤的干燥藤茎㊂性状鉴别要点:三叶木通皮部可见淡黄色或棕褐色颗粒状物,小木皮部易脱落,残存皮部边缘不整齐㊂图16 上为川木通,下为木通3 讨论本文提及的所有饮片均为‘中国药典“[2]或各省炮制规范[3-5]收载品种,一旦被判不合格,按照新修订的药品管理法,涉嫌以他种药品替代此种药品,可判为假药,无论生产还是经营企业,必然受到重罚严惩㊂这其中既有生产企业主观混淆视听㊁鱼目混珠㊁企图蒙混过关,也有企业进货把关不严,出厂检验草草了事走过场㊂笔者认为作为药品监督检验人员,必须牢记习总书记提出食药领域 四个最严 的要求,有必要练就出一双火眼金睛,尤其是基层一线药品监管人员,掌握了本文的快速检验方法,对于快速识别出假劣中药饮片并进行针对性抽样,防止其流入市场对于保障人民群众用药安全具有重要意义㊂参考文献[1]张萍,李宁新,李明华等.2019年全国中药材及饮片质量分析报告[J ].中国现代中药,2002(5):663-671.[2]国家药典委员会.中国药典2015年版四部[S ].北京:中国医药科技出版社,2015.[3]广西壮族自治区食品药品监督管理局.广西壮族自治区中药饮片炮制规范2007年版[S ].广西科学技术出版社,2007,69.[4]江西省食品药品监督管理局.江西省中药饮片炮制规范2008年版[S ].上海:上海科学技术出版社,2009,102.[5]新疆维吾尔自治区食品药品监督管理局.新疆维吾尔自治区中药维吾尔药饮片炮制规范2010年版[S ].乌鲁木齐:新疆人民出版社,2010,8.作者简介:徐岳鑫(1981-),男,江苏沭阳,硕士,副主任中药师,研究方向:药品检验㊂。

【F2的诱惑试用奥林巴斯大光圈定焦镜头】-大光圈定焦镜头

【F2的诱惑试用奥林巴斯大光圈定焦镜头】-大光圈定焦镜头

【F2的诱惑试用奥林巴斯大光圈定焦镜头】大光圈定焦镜头【F2的诱惑试用奥林巴斯大光圈定焦镜头】大光圈定焦镜头奥林巴斯的4/3系统推出来已经有些时日了,尽管我们也在第一时间试用了E-1和E-300相机,为读者介绍了这个全新的开放的数码相机标准,不过说实话,我们测试的都是随套机发售的普通镜头,而对于那些个“传说中”的顶级镜头,一直都是无缘相见。

所以这次有机会拿到了奥林巴斯4/3系统的两只各具特色的大光圈定焦镜头,机会不容错过。

到目前为止,奥林巴斯已经为它精心栽培的4/3系统推出了13款镜头,覆盖了从7mm一直到300mm的广阔范围,换算成实际焦距的话,就是从14mm至600mm,其中既有质优价廉的标准变焦镜头,也有超广角和超长焦的大光圈专业变焦镜头,既有8mm鱼眼镜头,也有微距和中长焦、超长焦距的大光圈定焦镜头,应该说,从镜头的焦距、覆盖范围、用途等方面都俨然组成了一个完整的镜头体系,足以满足绝大多数拍摄题材的需要了。

不过遗憾的是,目前在中国市场上,只有其中的9款镜头上市可以买到。

在这个镜头体系中,有两只最大光圈为F2的大光圈定焦镜头比较引人注目,一个是Zuiko Digital ED 50mm 1:2 Macro微距镜头,另一个是Zuiko Digital ED 150mm 1:2长焦镜头。

它们都是定焦镜头,它们的最大光圈都是F2,它们都是Zuiko Digital ED镜头,它们的焦段、定位、用途都非常明确,这些都吸引着我们想探个究竟。

于是在一个周末,我带着E-300相机和这两款镜头来到了坝上。

Zuiko Digital ED 50mm 1:2 Macro这是我见过的最为轻巧的中焦微距镜头了。

它的体积只有一只普通的标准镜头大小,实际焦距相当于135相机的100mm焦长,这正是生态摄影上最常使用的一个焦段,各个厂商在这个焦距段上都有很著名的微距镜头,比如腾龙的90mm 微距、适马的105mm微距、佳能的100mm微距、尼康的105mm微距等等,这些中焦微距镜头,都有着成熟的技术和工艺,都有着出色的光学品质,令广大的微距摄影爱好者趋之若骛。

第七期光学显微镜培训班日程(1)xls

第七期光学显微镜培训班日程(1)xls

日程时间内容培训讲师9:00-9:15到达,签到9:15-9:30致词 OCN LBD 齐京京部长9:30-9:45C-TEC介绍(C-TEC运营部李竞舟经理)李竞舟9:45-10:00合影讲座:光学显微镜的基础知识11:45-13:00午餐讲座:光学显微镜的基础知识实习操作:18:30晚宴讲座:数字摄影的基础与技术11:45-13:00午餐讲座:数字图像的采集、处理与分析C-TEC 东京厅C-TEC 正门口C-TEC 北京上海厅张江镇C-TEC 用餐区C-TEC 纽约厅C-TEC 东京厅C-TEC 用餐区张淼丽1、光学显微镜的分类(正置、倒置和体视显微镜);2、光学显微镜的七种观察方式(BF /DF /PH /RC /DIC /FL /PO);张淼丽1、柯勒照明的调节;2、光学显微镜七种观察方式(BF /DF /PH /RC /DIC /FL /PO)的调节;15:00-18:00位 鹏王万里周寅笑10:00-11:45星期二09:00-11:30潘小涛1、CCD基础理论;2、黑白CCD与彩色CCD的应用;3、EMCCD的原理及应用;第七期光学显微镜基础培训班日程表地 点:上海浦东新区张江高科技园区 奥林巴斯中国医疗教育培训中心样 机:BX51/BX63+DP73/IX71/体视显微镜-SZX7/电脑+软件地点5月28日星期一C-TEC 东京厅C-TEC 北京上海厅1、光学显微镜成像原理与无限远照明系统(柯勒照明、色温、滤色镜LBD、ND6/25、GV);2、光学显微镜观察系统(性能、分辨力、NA值、景深、实际视场);13:00-14:4514:50-15:20茶歇实习操作:讲座:激光扫描共聚焦11:45-13:00午餐13:15—15:30综合实习15:45-16:30考试、颁发证书山本部长16:30-18:00总结与自由交流5月30日星期三09:00-11:40C-TEC 北京上海厅C-TEC 纽约厅C-TEC 北京上海厅C-TEC 用餐区位 鹏1、激光扫描共聚焦显微镜的原理和应用;2、双光子显微镜和全内反射显微镜基础理论;C-TEC 用餐区C-TEC 东京厅13:00-14:5015:30-18:005月29日星期二王万里位 鹏王万里1、数字图像的获取与采集;2、数字图像的处理与分析;1、明场染色、非染色的图像获取方法;2、荧光图像、多通道荧光图像的获取方法;3、动态图像的获取方法;4、景深扩展(实时和已拍摄图像);5、大视野图像获取(实时和已拍摄图像);6、自动计数和测量;7、轨迹跟踪;8、图像反卷积;9、其它常用图像处理方法;C-TEC 纽约厅。

奥林巴斯BXiS金相显微镜系统: 数码成像无缝集成 正立金相显微镜BXiS 1 使用说明书

奥林巴斯BXiS金相显微镜系统: 数码成像无缝集成 正立金相显微镜BXiS 1 使用说明书

BXiS 金相显微镜系统:数码成像无缝集成正立金相显微镜BXiS今日,各种各样的检查应用,都要求光学检查系统能够以多种方式完成高效的图像处理工作。

无论您是需要使用白光成像进行基本的测量,还是需要使用具有色彩高保真度的偏振光进行严格的材料鉴定,奥林巴斯都能以其灵活的方案满足您的需求。

BXiS ——您的个性风格。

在奥林巴斯产品方案中,高级显微镜产品可搭载特定的数码显微照相装置,保证了图像的高分辨率和精确的色彩还原。

奥林巴斯全面解决方案还包括高级图像软件。

该软件融合了各种操作功能,包括基本的图像拍摄、图像处理、报表生成、数据导出以及数据、图像和报表的全球网络连接共享。

BXiS ——您的个性系统。

奥林巴斯允许用户自由创建工作方案以满足不同环境的工作流程和其它需要。

用户在专心工作的同时,奥林巴斯还给用户提供了各种便捷、省时的工具,让日常的例行工作也变得轻松容易。

BXiS ——您的个性方案。

BXiS 系统——不论是现在还是未来,都能满足您个性风格的任何操作应用拥有 BX iS , iS 代表您的个性风格(i ndividual S tyle )。

3多用途系统,满足您的个性风格奥林巴斯致力于创建可支持各种级别工作的显微镜系统方案5让工作流程精简高效OLYMPUS Stream 软件,满足您的每个需求BXiS 简化图像的拍摄流程BXiS 操作,不易疲劳9创建个人专属的奥林巴斯系统BXiS 按您的样本和方案设计完美的系统BXiS 拥有各种物镜各种奥林巴斯数码照相装置BXiS 拍摄您需要的图像从简单测量到复杂的图像分析16轻松扩展至未来的应用程序BXiS 的扩展功能可适应未来的需要奥林巴斯系统支持升级功能17系统图、规格BX51 / BX51M / BXFM 系统图BX61 系统图BX41M-LED 系统图BX51 IR 系统图规格外形尺寸让工作流程精简高效时间和工作环境同样重要,这正是BXiS的图像和控制软件可以个性化设置工作流程的原因。

奥林巴斯IX73倒置荧光显微镜使用说明-FudanUniversity

奥林巴斯IX73倒置荧光显微镜使用说明-FudanUniversity

奥林巴斯IX73倒置荧光显微镜使用说明本内容主要分为以下几个章节:一、明场方式的使用说明二、相差方式的使用说明三、微分干涉(DIC)方式的使用说明四、荧光方式的使用说明五、软件的相关使用说明六、图片组合的使用说明七、图像拼接的使用说明八、景深扩展的使用说明九、时间序列的使用说明十、维护与保养注:荧光开关是桔黄色荧光笔标注。

拷贝数据请用新的光盘。

一、明场方式的使用说明1.打开明场光源A;2.摁下显微镜机身前B按钮,并调节光强旋钮以获得合适的光强;3.选择适当的物镜,并将聚光镜上的调节环D转至5号位即BF;4.将荧光滤光块F转至5号位即BF;5.根据需要将光路切换杆调至100%目镜或50%相机和50%目镜的位置;6.调节调焦旋钮,获得清晰的明场图像。

1.打开明场光源A;2.摁下显微镜机身前B按钮,并调节光强旋钮以获得合适的光强;3.根据需要,选择4X,10X,20X,40X中的一个物镜,并将聚光镜上的调节环D 转至相应的号位(4X物镜用PHL;10X和20X物镜用PH1;40X物镜用PH2);4.将荧光滤光块F转至5号位即BF;5.根据需要将光路切换杆调至100%目镜或50%相机和50%目镜的位置;6.调节调焦旋钮,获得清晰的相差图像。

三、微分干涉(DIC)方式的使用说明1.打开明场光源A;2.摁下显微镜机身前B按钮,并调节光强旋钮以获得合适的光强;3.将起偏镜移动手把即C推至右侧;4.选择60X的物镜,并将聚光镜上的调节环D转至4号位;5.将DIC滑座即E向里推入至卡住;6.将荧光滤色块F转至4号位即DIC;7.根据需要将光路切换杆调至100%目镜或50%相机和50%目镜的位置;8.调节调焦旋钮,获得清晰的微分干涉图像。

1.在明场观察方式下获得清晰的图像后,调节光强旋钮至最弱,并关闭显微镜机身前B按钮(如果不再使用明场方式观察,请将明场光源A 关闭);2.接下来请查看荧光开关,即桔黄色荧光笔标注;3.打开荧光光源A,接着打开SHUTTER开关B;4.根据需要,将荧光滤色块F转至1、2、3、6中的一个号位;5.按压一次外接控制器圆按键C打开荧光(再按压一次即会关闭),并旋转圆按键C调节荧光光强;6.根据需要将光路切换杆调至100%目镜或50%相机和50%目镜的位置;7.调节调焦旋钮,获得清晰的荧光图像。

奥林巴斯软镜服务要求-深圳第三人民医院

奥林巴斯软镜服务要求-深圳第三人民医院

招标项目要求一、项目背景本次项目为深圳市第三人民医院的奥林巴斯软镜维修保养服务。

服务商必须按国家、行业的标准及谈判文件的要求对项目内的设备进行系统的、全面的检测、维护及保养,以保证设备的高效、正常运作。

二、具体技术要求(一)项目内容:1. 项目内容:深圳市第三人民医院的奥林巴斯软镜维修保养服务(其它与周边仪器相关的不可维修的设备和耗品不属于维修范围,不列入合同范围内)2. 项目实施地点:深圳市第三人民医院院内3. 设备品牌:奥林巴斯4. 设备型号及数量:详见设备清单(二)项目要求:1.维修服务:完全实施免费维修,零配件费、人工费、技术检测费及其它不可预测的费用均已包含于合同总价之中,保证零件为原厂维修零件,为确保维修品质和安全问题,如出现维修品质问题,医院有权要求服务商将设备交予奥林巴斯原厂维修,费用由服务商负责。

2. 定期保养:每年_4_次预防性保养,并提供报告单及维护记录;根据设备现状或科室需求,有针对性地对使用人员培训相关设备的操作技术。

3. 响应速度:应急维修 8_小时内响应,_24_小时到达现场维护,如不能解决问题,将提供相应备品。

4. 备品供应:服务商承诺3个工作日内提供相应备品,且备品必须是维修品同一系列的备品。

5. 服务商承诺,服务商以及受服务商指派从事维保服务的人员均具有相应的资格,完全能胜任服务的要求。

服务商承诺将指定原厂工程师或经原厂培训认证的工程师(提供相应证书或者证明)专门负责甲方的维修和相应的培训工作,如指定工程师有变更,将另行通知甲方变更情况。

周一至周五,一旦服务范围内的设备出现故障,工程师保证_24_小时内提供现场支持,并提供24小时×7天的电话支持。

6. 服务商对设备进行的日常检查、维护、保养、维修等活动在没有更优的方案时,应严格按照设备原厂的维修保养要求进行。

7. 修理厂家资质:为确保维修品质,服务商承诺修理厂家拥有以下三个认证证书:ISO9001认证,ISO13485认证、ISO14001认证。

打鸟神器_试用奥林巴斯M.ZUIKO_DIGITAL_ED_150-400mm_F4.5_TC1.2

打鸟神器_试用奥林巴斯M.ZUIKO_DIGITAL_ED_150-400mm_F4.5_TC1.2
镁铝合金、碳纤维强化塑料(CFRP)与碳纤维等材料的大量使用,使这款镜头 达到强度与精准度的同时,体积和重量得到了很少的控制,不装上遮光罩的情况下长 度仅314.3mm,重量为1875g,体现出轻便小巧的特点。
镜头的前部加装有代表着奥林巴斯专业镜头的蓝色环带,给人一种专业的感 觉。它内置了一个1.25×的增距镜,为了方便操作,集成式增距镜采用快速开关与 锁定设计,操作非常简单,整个操作过程可在通过取景器取景的同时轻松实现。另 外,它还兼容选配的增距镜M C-14/M C-20,在延长焦距的同时,主镜头的光学性能
图15 图16
现被认为是当今世界上唯一的野生朱鹮 种群。得益于近40余年来的保护,目前 全世界的朱鹮数量重新回到了1万只以 上,这被国际公认为濒危动物保护的 典范。
这次去的是洋县的其中一个拍摄 点,那里有一颗苦楝树,被“鸟导”刻 意训练过的朱鹮,每天早晨和傍晚都会 飞到这颗苦楝树上休息。每年的11月份 前后,全国各地的鸟友都会到这颗苦楝 树前,拍摄朱鹮起飞和降落的瞬间。
试用体会
因2023 Panasonic杯“魅力中国”
图6 笔者手持 OM-1相机+奥林巴斯M.ZUIKO DIGITAL ED 150-400mm F4.5 TC1.25× IS PRO镜头拍摄
照相机 21
2023.12 / 使用报告
图7 白鹭抓鱼瞬间
图8 小䴙䴘
图9 翠鸟 22 照相机
的高速S D卡价格并不便宜,而且性能相比读写速度达到1700M B/s的 CFexpress卡落后太多太多,奥之心应该在后续机型考虑对CFexpress 卡的支持。
这款镜头加入人性化设计,在拍摄 时可以方便调整各项设置与功能。配备 的高精准橡胶对焦环/变焦环,可以实施 精细的操控。这款镜头还具备焦点记 忆功能,方便用户随时保存理想的焦 点位置。

奥林巴斯普外科配套和参数

奥林巴斯普外科配套和参数

奥林巴斯高清腹腔镜配置单S7PRO高清腹腔镜系统:型号名称OTV-S7Pro 摄像系统主机CLV-S40Pro 内窥镜冷光源UHI-E 气腹机YQT-781 气腹机配件上(减压阀,过滤器,高压管)O5151.1 气腹针,Veress式N3808200 SWISSBIT CF卡(1GB)/JST PC卡适配器套装WA53005A 腹腔镜,10mm,30°HD,速锁,可高温高压火菌OTV-S7ProH-HD-12E 高清摄像头WA03210A 导光束,M号,插销型,3cm,CF型TC-1 专用台车SONY24寸高清液晶医用监视器图文工作站高清腹腔镜性能描述一、高清图像处理中心1.*视频信号输出方式:HDTV 信号输出,1080线扫描。

1.*亮度调节:通过调光电缆与光源连接,实现自动亮度强度调节。

2.测光模式:可进行峰值和自动测光的功能。

3.*图像增强功能:分四档电子化增强图像的轮廓和结构成像过程。

4.摄像感光度(AGC):当内镜远端离目标太远而导致光线不足时,可对图像亮度及信号进行电子放大。

5.画中画功能:可便捷实现副画面显示。

6.*NBI功能:利用窄带光照明模式,可增强组织表层血管和其它组织的显像性能。

7.*PC卡记忆功能:主机具有图像直接存储于机上XD-PC卡8.*DV输出:数字化视频流可直接输出到数字化显示设备和数字化录制设备。

9.遥控开关设置:摄像头或电子内镜上的遥控开关可以设置十种主机操作功能;10.色彩调节:红色±8级,蓝色±8级,色度±8级;11.*可进行电子胆道镜的联接;二、氙灯光源:1、*功率为300W高辉度氙气冷光源;2、灯泡寿命:持续使用500小时以上,具有后备灯;3、自动调光和手动调光功能;4、具有高亮度模式功能;5、*具有NBI窄带光成像功能;三、全自动气腹机技术参数1.包括气腹针、气瓶接头,外置减压阀;2.有内置减压阀,可连接钢瓶或中心供气;3.有总耗气量计数及清零;4.有钢瓶压力过低,腹内压过高以及管道堵塞报警功能;5.电击保护等级:CF级。

奥林巴斯OLYMPUS digital cameraFE-120 X-700 senior Manual说明书

奥林巴斯OLYMPUS digital cameraFE-120 X-700 senior Manual说明书

连拍 ........................................................................................... 48
自拍 ............................................................................................ 49
使用直接按钮............................................................................... 15 如何使用菜单..................................................................................... 16
1 基本操作- - - - - - - - - - - - - - - - - - - - - - - - - - - - -8
如何使用拍摄钮和播放钮..................................................................... 9 如何使用模式拨盘 ............................................................................. 12 如何使用直接按钮 ............................................................................. 13
如何聚焦(聚焦锁定) ................................................................ 24 难以聚焦的被摄对象.................................................................... 25 记录模式 ..................................................................................... 26 静止图像记录模式 ....................................................................... 26 动画记录模式............................................................................... 27 可存储静止图像数/剩余记录时间 .............................................. 27 改变记录模式............................................................................... 28 记录图像............................................................................................ 29 内存和插卡之间的关系 ................................................................ 29 使用插卡............................................................................................ 30 插卡小知识 .................................................................................. 30 插入插卡...................................................................................... 30 电池 ................................................................................................... 33

奥林巴斯研究级正置数码显微镜BX51DP71

奥林巴斯研究级正置数码显微镜BX51DP71

奥林巴斯研究级正置数码显微镜BX51 / DP71用途:可观察普通染色的切片,用于研究工作。

1.工作条件1.1 适于在气温为摄氏-40℃~+50℃的环境条件下运输和贮存,在电源220V( 10%)/50Hz、气温摄氏-5℃~40℃和相对湿度85%的环境条件下运行。

1.2 配置符合中国有关标准要求的插头,或提供适当的转换插座。

2.主要技术指标2.1 研究级正置万能荧光显微镜*2.1.1 研究级正置万能显微镜,明场(BF)观察、预留:荧光(FL)、微分干涉(DIC)、偏光(POL)、暗场(DF)的观察2.1.2 光学系统:无限远校正光学系统*2.1.3 调焦:载物台垂直运动方式距离不小于25mm,带聚焦粗调上限停止位置,粗调旋钮扭矩可调,最小微调刻度单位≤1微米*2.1.4 观察镜筒:宽视野三目镜筒,视场数≥26.52.1.5 照明装置:内装式透射光柯勒照明器,12V100W卤素灯,光量预调开关,光强度发光二极管指示灯,内装式滤色镜(日光平衡滤色片、中性灰度滤色片)。

*2.1.6 物镜:平场半复消色差物镜4X(N.A.≥0.13,W.D.≥17),视野数≥26.510X(N.A. ≥0.30,W.D. ≥10),视野数≥26.520X(N.A. ≥0.5,W.D. ≥2.1 弹簧),视野数≥26.540X(N.A. ≥0.75,W.D. ≥0.51弹簧),视野数≥26.560X(N.A. ≥0.9,W.D. ≥0.2弹簧),视野数≥26.5100X(N.A. ≥1.3,W.D.≥0.2弹簧,油),视野数≥26.52.1.7 载物台:右手低位置同轴驱动选钮的高抗磨损性陶瓷覆盖层载物台。

*2.1.8 目镜:10X宽视野目镜,视野数≥26.5;2.1.9 物镜转换器:六孔物镜转换器*2.1.10 万能聚光镜:N.A≥1.42.2 显微图像分析系统2.2.1 高分辨率显微专用数码相机2.2.1.1 感光芯片规格:2/3英寸像素移动彩色CCD*2.2.1.2 CCD光敏感度调节:≥ISO1600*2.2.1.3 分辨率:≥1250万像素(最高分辨率4080 X 3072)*2.2.1.4 制冷系统:低于环境温度10度*2.2.1.5 测光方式:≤0.1%点测光,任意选择测光区域*2.2.1.6 图像刷新速度:≥15 幅/秒(≥1360 X 1024)2.2.1.7 像素混合模式:2x2及4x4模式2.2.1.8 图像传输速度:3秒(最高分辨率4080 X 3072时)2.2.1.9 白平衡调节方式:自动/ 手动/ 点触式2.2.1.10 视频接口:0.5X C型接口*2.2.2 显微图象分析软件2.2.2.1 采集图象:支持多种专业CCD和模拟摄相头,支持twain接口2.2.2.2 图象增强、处理;自动、手动图象拼接;扩展视野景深;自动、手动图象位置校对,多维图象管理;彩色通道管理:多通道荧光的色彩叠加,适合于多重荧光标记观察、FISH荧光观察等;自动化报告生成器;本地放大功能2.2.2.3 测量功能:随意对图象切割、测量、计数、分类;HE等染色方法的阳性灰度、阳性比例计算;简单电泳条带分析;荧光强度分析等。

奥林巴斯内窥镜和电子设备退修指南说明书

奥林巴斯内窥镜和电子设备退修指南说明书

November 3, 2014RE: Guidelines for Returning Olympus Endoscopes and Electronic Equipment for Repair in the United StatesDear Healthcare Practitioner:The purpose of this letter is to provide guidance to customers on our requirements when sending Olympus endoscopy equipment to Olympus service centers located in the United States for repair. All equipment, including flexible endoscopes, rigid endoscopes, and electronic equipment must be rendered safe to handle prior to being returned to Olympus for repair. To accomplish this, all endoscopes must be cleaned AND high-level disinfected or sterilized prior to shipment to a service center for repair.Olympus Electronic Equipment must be wiped with an appropriate surface disinfectant, such as Sani-Cloth® Plus Germicidal Disposable Cloths manufactured by PDI.In addition, Olympus requires that the cleaning AND high-level disinfection or sterilization process be verified prior to initiation of repair. To expedite repair of your equipment, please contact Olympus at 800-848-9024 to generate a service RMA. Please complete the Reprocessing Verification section on the equipment service request form provided. You may also generate an RMA and complete the Reprocessing Verification on-line at/serviceportal.Please include the equipment service request form or portal confirmation with your equipment. If Olympus equipment is received without a Reprocessing Verification, Olympus will contact the customer to verify proper reprocessing prior to initiating repair. Endoscopes that have not been cleaned AND high-level disinfected or sterilized will be returned to the customer without being repaired.Mandatory Surface Disinfection of Electronic EquipmentPrior to returning Olympus electronic equipment for repair, wipe all surfaces of the electronic equipment (e.g., the video system center or light source) with a disinfectant wipe, such as Sani-Cloth® Plus Germicidal Disposable Cloths manufactured by PDI. Follow the product’s instructions for use regarding how to wipe and the required contact time for the product to be effective. For example, Sani-Cloth® Plus Germicidal Disposable Cloths require a 5-minute contact time.Mandatory Cleaning and Disinfection or Sterilization of Rigid Endoscopes:Prior to sending rigid endoscopes to Olympus for repair, reprocess them according to the product-specific instruction manual and/or Endoscopy System Guide (if applicable), which includes the steps of cleaning, high-level disinfection and/or sterilization.Mandatory Cleaning and Disinfection or Sterilization of Flexible Endoscopes:For flexible endoscopes, refer to the reprocessing manual that accompanies each endoscope for instructions on proper manual cleaning, high level disinfection and/or sterilization, which is required prior to returning the equipment to Olympus for repair.The following information provides guidance on how to reprocess damaged flexible endoscopes to render them safe to handle. Damaged endoscopes that are still watertight should be reprocessed according to instructions provided in the Olympus reprocessing manual. However, if the endoscope has developed a leak, routine reprocessing may lead to further damage. Therefore, Olympus has developed special guidelines for flexible endoscopes that have failed leakage testing.The key to preventing further damage to a leaking endoscope is to provide positive pressure to the endoscope during all phases of the reprocessing cycle by connecting the endoscope to the maintenance unit (Olympus model MU-1) or light source. This will ensure that the endoscope is pressurized throughout the entire reprocessing cycle and will help to prevent fluid from entering the endoscope.A leak in the endoscope will be indicated by a continuous series of bubbles emerging from a location on the endoscope. Before removing the endoscope from the water, identify and make note of the location of the leak. With the maintenance unit or light source still turned on and the leakage tester still connected, remove the endoscope from the water. If the maintenance unit or light source is turned off while the endoscope is immersed, water may invade the internal spaces and further damage the endoscope.Mandatory Manual Cleaning for Leaking Endoscopes1. For a leak detected in the covering of the insertion tube, bending section, or universalcord, turn the maintenance unit OFF. Detach the leakage tester from the maintenance unit or the light source. Wait 30 seconds or until the covering of the bending section contracts to its pre-expansion size. Detach the leakage tester from the endoscope. Thoroughly drythe identified location of the leak on the outer area of the scope using alcohol and a clean lint-free cloth. Carefully apply a piece of electrical tape over the location of the leak prior to immersing the endoscope in detergent solution. Wrapping the tape too tightly mayresult in damage to the endoscope. For leaks detected in other locations (e.g., internalchannel), proceed with the instructions provided below.Note: Please be advised that Olympus recommends use of a colored tape, such as red,yellow, or blue to allow for easier visual identification of a scope in need of repair afterleak testing and cleaning. It is further recommended that customers develop apath/segregation technique for endoscopes requiring repair to minimize the possibility of reuse prior to being returned to Olympus for repair.2. Fill a basin with detergent solution at the temperature and concentration recommendedby the detergent manufacturer. Use a basin that is at least 40 cm by 40 cm (16” by 16”) in size and deep enough to allow the endoscope to be completely immersed.3. Insert the leakage tester connector into the output socket of the maintenance unit or thelight source and turn the maintenance unit or the light source ON. Set the light source’sairflow regulator switch to “HIGH” or “3.”4. Connect the leakage tester’s connector cap to the venting connector of the water-resistant cap. For 190-series endoscopes, the leakage test connects directly to the venting connector.5. Fully immerse the endoscope in the detergent solution.6. Perform manual cleaning according to the instructions provided in the reprocessingmanual. Minimize unnecessary flexion of the insertion tube and universal cord duringcleaning.Mandatory High-Level Disinfection or Sterilization for Leaking Endoscopes1.Sterilization:Following manual cleaning, the preferred method of rendering a leaking endoscope safe to handle is ethylene oxide sterilization. Ethylene oxide sterilization should be performedaccording to the instructions provided in the endoscope’s reprocessing manual. If electrical tape was applied to a leak detected in the endoscope’s external surface, remove the tape and wipe with 70% ethyl or isopropyl alcohol prior to ethylene oxide sterilization.If ethylene oxide sterilization is not possible, perform high-level disinfection or STERRADsterilization according to the instructions provided below.Sterilization in a STERRAD sterilization system is also an acceptable alternative practice provided the endoscope is listed as materially compatible with the STERRAD sterilization system. Those endoscope models which are compatible with STERRAD sterilization may be sterilized using the normally recommended STERRAD model, cycle and conditions (e.g., check booster requirements) as long as the following requirements are met: 1) The endoscope has been properly cleaned and dried, and 2) Fluid has not invaded the endoscope. Retained fluid will cause the STERRAD cycle to abort and may contribute to additional repairs.2.Manual High-Level Disinfection:a.Fill a basin with disinfectant solution at the temperature and concentration recommendedby the disinfectant manufacturer. Use a basin that is at least 40 cm by 40 cm (16” by 16”) in size and deep enough to allow the endoscope to be completely immersed.b.Insert the leakage tester connector into the output socket of the maintenance unit or thelight source and turn the maintenance unit or the light source ON. Set the light source’sairflow regulator switch to “HIGH” or “3.”c.Connect the leakage tester’s connector cap to the venting connector of the water-resistantcap (140/160/180-series) or endoscope directly (190-series).d.Immerse the endoscope in the disinfectant solution.e.Perform the high-level disinfection procedure described in the endoscope’s reprocessingmanual. Minimize unnecessary flexion of the insertion tube and universal cord duringreprocessing.3. Automated High-Level DisinfectionAutomated Endoscope Reprocessors (AERs) circulate high-pressure fluid through the internal channels of the endoscope, which may result in fluid invasion and further damage to aleaking endoscope. As a result, Olympus recommends performing the manual high-level disinfection procedure on leaking endoscopes.However, some AERs are designed to maintain positive pressure to the internal cavities of the endoscope in order to prevent fluid invasion during the reprocessing cycle. Check with your AER manufacturer to determine whether your AER is intended to reprocess leakingendoscopes and whether positive pressure can be maintained during the disinfection cycle without aborting the cycle.If you have any additional questions, please contact your local Olympus sales representative or the Olympus Technical Assistance Center at 1-800-848-9024 (United States). Thank you. Sincerely,Mary Ann Drosnock, MS, CIC, CFER, RM (NRCM)Manager of Infection ControlOlympus America Inc.****************************。

奥林巴斯偏光显微镜安全操作及保养规程

奥林巴斯偏光显微镜安全操作及保养规程

奥林巴斯偏光显微镜安全操作及保养规程一、前言奥林巴斯偏光显微镜是应用于各种材料科学领域的重要仪器之一。

为保证用户的安全和设备的正常运行,需要严格遵守安全操作规程以及进行定期的设备维护和保养。

本文旨在针对奥林巴斯偏光显微镜的安全操作和保养规程进行明确和详细的阐述,以提高使用者的操作技能和设备的使用寿命。

二、安全操作规程1. 前置准备工作•在进行操作前,应确保操作台面干净整洁,其上无杂物和污渍;•确认试样已经制备完毕,并确保放置在操作台面上稳固无松动;•操作者应穿戴好实验室安全装备,如实验室大衣、手套等,避免接触强酸碱以及与试样接触时的伤害。

2. 开机前准备•确认电线正确连接到用电源,并确认电源开关处于关闭状态;•将电源插头插入设备电源插座;•确认偏光片处于安装状态,而不是拆卸状态;•确认光学元件处于正确的位置;•去除显微镜工作平台上的任何杂物和模版等,以免发生意外。

3. 开机操作•按下电源开关,将设备接通电源;•电源指示灯亮起,表明设备已经开启;•等待几分钟,让设备进行预热和自检;•开始设备调试和观测。

4. 关机操作•调整镜头位置,以便下一次观察;•将偏光片置于拆卸状态,以便下次使用;•按下电源开关,将设备断开电源;•将电源线从电源插座拔出;•清理操作台面以及设备表面。

5. 注意事项•在进行显微镜观察时,应保持设备平衡和稳定,避免观察角度变化过大;•避免强光照射到显微镜物镜和偏光片上,以免影响观察效果;•遵守操作手册中关于设备保护和维护的规定;•当设备出现故障时,应及时联系专业技术人员进行维护和修理,避免自行拆卸和修理。

三、保养与维护1. 日常保养•定期清理设备表面和操作台面,特别注意光学元件的保护;•使用避免使用超过设备规定最大功率的光源;•定期更换滤光片和偏光片。

2. 定期保养•定期维修和调整光学元件;•定期检查设备电源插头和电线连接状态;•定期清理润滑各部件,并添加润滑剂;•定期更换损坏的配件或元件;•定期校准设备。

荧光显微镜使用说明

荧光显微镜使用说明

荧光显微镜使用说明奥林巴斯荧光显微镜操作规程该荧光显微镜为奥林巴斯DP72,本荧光显微镜可作为明视场显微镜使用,也可作为荧光显微镜使用,根据需要,开启相应的电源。

禁止乱调设置,以免影响他人正常使用。

1、作为明视场显微镜使用:(1)接通电源后,打开显微镜底座左侧的电源开关,按光亮需要调节底座前侧的滑竿。

(2)根据需要,调节底座光栅和聚光器光栅及其高度,可获得最佳的图像效果。

采集单幅图像1. 切换到“采集”布局。

为此,请使用 (例如)“视图>布局>采集”命令。

2. 在“摄像控制”工具窗口中单击实时观察按钮。

选定物镜3. 在“显微镜控制”工具栏上,单击您想要用于图像采集的物镜所对应的按钮。

打开实时图像4. 转到实时图像中所需的样品位置。

设置图像质量5. 对焦到样品上。

当对焦到样品上时可以使用此处的“聚焦指针”工具栏。

6. 核对色彩再现。

如有必要,请执行白平衡。

7. 核对曝光时间。

您既可以使用自动曝光时间功能,又可以手动输入曝光时间。

8. 选定所需的分辨率。

采集和保存图像9. 在“摄像控制”工具窗口中单击“拍照”按钮。

所采集的图像将会显示在文档组中。

10. 使用“文件>另存为...” 命令保存该图像。

请使用推荐的 TIF 文件格式。

采集录像1. 切换至“采集”布局。

为此,请使用 (例如)“视图>布局>采集”命令。

选定物镜2. 在“显微镜控制”工具栏上,单击您希望用于采集录像的物镜的按钮。

选定存储位置3. 在“摄像控制”工具窗口的工具栏中,单击“采图设置”按钮。

采图设置对话框即会打开。

4. 在树状视图中选定“保存>录像”选项。

5. 确定在采集流程完成后如何保存所录制的录像。

选定“自动保存”目标位置列表中的“文件系统”选项自动存储记录的录像。

位于目录组中的路径字段显示录像自动保存时使用的目录。

6. 单击“路径”字段旁边的 [...] 按钮可更改此目录。

选定压缩方法文件类型列表中预设的是AVI文件格式。

奥林巴斯研究级正置数码显微镜BX51DP71

奥林巴斯研究级正置数码显微镜BX51DP71

奥林巴斯研究级正置数码显微镜BX51 / DP71用途:可观察普通染色的切片,用于研究工作。

1.工作条件1.1 适于在气温为摄氏-40℃~+50℃的环境条件下运输和贮存,在电源220V( 10%)/50Hz、气温摄氏-5℃~40℃和相对湿度85%的环境条件下运行。

1.2 配置符合中国有关标准要求的插头,或提供适当的转换插座。

2.主要技术指标2.1 研究级正置万能荧光显微镜*2.1.1 研究级正置万能显微镜,明场(BF)观察、预留:荧光(FL)、微分干涉(DIC)、偏光(POL)、暗场(DF)的观察2.1.2 光学系统:无限远校正光学系统*2.1.3 调焦:载物台垂直运动方式距离不小于25mm,带聚焦粗调上限停止位置,粗调旋钮扭矩可调,最小微调刻度单位≤1微米*2.1.4 观察镜筒:宽视野三目镜筒,视场数≥26.52.1.5 照明装置:内装式透射光柯勒照明器,12V100W卤素灯,光量预调开关,光强度发光二极管指示灯,内装式滤色镜(日光平衡滤色片、中性灰度滤色片)。

*2.1.6 物镜:平场半复消色差物镜4X(N.A.≥0.13,W.D.≥17),视野数≥26.510X(N.A. ≥0.30,W.D. ≥10),视野数≥26.520X(N.A. ≥0.5,W.D. ≥2.1 弹簧),视野数≥26.540X(N.A. ≥0.75,W.D. ≥0.51弹簧),视野数≥26.560X(N.A. ≥0.9,W.D. ≥0.2弹簧),视野数≥26.5100X(N.A. ≥1.3,W.D.≥0.2弹簧,油),视野数≥26.52.1.7 载物台:右手低位置同轴驱动选钮的高抗磨损性陶瓷覆盖层载物台。

*2.1.8 目镜:10X宽视野目镜,视野数≥26.5;2.1.9 物镜转换器:六孔物镜转换器*2.1.10 万能聚光镜:N.A≥1.42.2 显微图像分析系统2.2.1 高分辨率显微专用数码相机2.2.1.1 感光芯片规格:2/3英寸像素移动彩色CCD*2.2.1.2 CCD光敏感度调节:≥ISO1600*2.2.1.3 分辨率:≥1250万像素(最高分辨率4080 X 3072)*2.2.1.4 制冷系统:低于环境温度10度*2.2.1.5 测光方式:≤0.1%点测光,任意选择测光区域*2.2.1.6 图像刷新速度:≥15 幅/秒(≥1360 X 1024)2.2.1.7 像素混合模式:2x2及4x4模式2.2.1.8 图像传输速度:3秒(最高分辨率4080 X 3072时)2.2.1.9 白平衡调节方式:自动/ 手动/ 点触式2.2.1.10 视频接口:0.5X C型接口*2.2.2 显微图象分析软件2.2.2.1 采集图象:支持多种专业CCD和模拟摄相头,支持twain接口2.2.2.2 图象增强、处理;自动、手动图象拼接;扩展视野景深;自动、手动图象位置校对,多维图象管理;彩色通道管理:多通道荧光的色彩叠加,适合于多重荧光标记观察、FISH荧光观察等;自动化报告生成器;本地放大功能2.2.2.3 测量功能:随意对图象切割、测量、计数、分类;HE等染色方法的阳性灰度、阳性比例计算;简单电泳条带分析;荧光强度分析等。

奥林巴斯OLYMPUS 数码相机digital camera D-595 ZOOM C-500 ZOOM Manual说明书

奥林巴斯OLYMPUS 数码相机digital camera D-595 ZOOM C-500 ZOOM Manual说明书
记录模式 ..................................................................................... 27 静止图像记录模式 ....................................................................... 27 动画记录模式............................................................................... 28 可存储静止图像数/剩余记录时间 .............................................. 28 改变记录模式............................................................................... 29
拍摄动画时的录音 .................................................................. 51
连拍 ........................................................................................... 52
关于菜单...................................................................................... 16 使用菜单...................................................................................... 19 如何阅读步骤页 ................................................................................. 21

奥林巴斯荧光显微镜

奥林巴斯荧光显微镜

奥林巴斯荧光显微镜发出荧光,然后在显微镜下观察物体的形状及其所在位置。

荧光显微镜用于研究细胞内物质的吸收、运输、化学物质的分布及定位等。

细胞中有些物质,如叶绿素等,受紫外线照射后可发荧光;另有一些物质本身虽不能发荧光,但如果用荧光染料或荧光抗体染色后,经紫外线照射亦可发荧光,荧光显微镜就是对这类物质进行定性和定量研究的工具之一。

奥林巴斯荧光显微镜产品参数:奥林巴斯荧光显微镜:奥林巴斯荧光显微镜_微分干涉显微镜_台式显微镜_IX73随着活体荧光蛋白和新型荧光探针在生命科学中的广泛应用,以各种荧光方法为代表的活细胞复杂实验已经成为生命科学研究者的首选。

奥林巴斯顺应这一潮流,满足广大研究者对倒置显微镜扩展性,高效性,准确性和操作简单的要求,集中一批创造性的研发人员历时2年多集合最新的机光电技术,全新设计和开发了最新一代研究级倒置显微镜IX73。

新型IX3系列做为能提供活细胞成像的高度可扩展的光学平台,其建立在雄厚的技术基础之上,拥有灵活的结构,容易利用的光路,提供高分辨,高反差的宽场图像。

一切设计基于用户的心声,科学家的工作流程需要,广泛应用在细胞生物学,神经生物学,发育生物学,分子生物学,光生物学等领域,将成为科研工作者进行更高水平的活细胞研究的最有力武器。

层式光路结构IX73根据用户需要可根据应用灵活配置单层光路和双层光路,加上其它显微镜部件,能够实现多种成像技术。

从长时间的序列成像和其它所需的前沿技术到临时的文件记录。

适用的模块包括:荧光滤色片转盘、侧端口、物镜倍率变换器等。

模块安装方便,使用户能够构建一个简单的独特灵活系统。

高NA物镜高NA相差复消色差物镜(UPLSAPO100×OPH,PLAPON60×OPH)能够实现高精确度观察,即使是在同时进行的相差观察和荧光观察过程中,也不必再更换物镜。

高NA硅油物镜(UPLSAPO30×S和UPLSAPO60×S)使用硅油作为中间介质,其折射率(ne ≈1.40),接近于活细胞组织的折射率(ne≈1.38),更有利于活细胞时间序列成像的正常观察。

相关主题
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

NEW• OLYMPUS CORPORATION is ISO14001 certified.• OLYMPUS CORPORATION is FM553994/ISO9001 certified.• Windows is either registered trademark or trademark of Microsoft Corporation in the United States and/or other countries. All other company and product names are registered trademarks and/or trademarks of their respective owners.• Images on the PC monitors are simulated.• Specifications and appearances are subject to change without any notice or obligation on the part of the manufacturer.DP73 is the environmental conscious product according to OLYMPUS' own standards.DP73Specimen(s) courtesy of :JAPANESE FOUNDATION FOR CANCER RESEARCH Cancer Chemotherapy Center Yuji Mishima, Ph.D.Kiyohiko Hatake, M.D., Ph.D. (page 4, upper)JAPANESE FOUNDATION FOR CANCER RESEARCH Cancer Institute, Cancer Institute Hospital Department of PathologyKengo Takeuchi, M.D., Ph.D. (page 3, lower right) Futoshi Akiyama, M.D., Ph.D. (page 2, lower)Yuichi Ishikawa, M.D., Ph.D. (page 3, upper; page 3, lower right)Replacement parts are available for 5 years after purchase.Exceptional Resolution and Color Reproduction for Clearly Outstanding ValueHigh-level Performance Display for Live Images during Low Magnification Observation■ Live, High-definition Images at 15 Frames per Second, Without CompressionHigh-definition 1600 x 1200-pixel images can be displayed live at a rate of 15 frames per second,without compression. Such imaging quality enables even the finest cellular regions to be observed clearly and distinctly without deterioration, while focusing is made stress free. Do away with the difficulties of observing microstructures and fine lines in low magnification and move forward to the clarity of the DP73's optimized conference-viewing application.Live, High-definition,1600 x 1200-pixel Images Free from CompressionNew Fluorescence Image QualityImproved Resolution Improved ResolutionAdvanced Color ReproductionConventional processingFine-detail Processing for Sharp, Intricate Results■ Improved Resolution, with Reduced Pseudo-colors and Moiré ArtifactsThe DP73 has the power to minimize pseudo-colors and moiré artifacts that can otherwise have anegative impact on resolution and cause problems during low magnification observation. This is because it features the same new algorithms and fine-detail processing for enhanced resolution as those built into high-grade Olympus digital SLR cameras. The DP73 also optimizes the resolving power of the objectives to further improve the sharpness and clarity of images.The DP73 displays live digital images with gradual smoothness and combines exceptional resolution with faithful color reproduction. It also offers outstanding operational ease, even when focusing and moving the observation site, to deliver a feel similar to viewing an image directly through the microscope. Furthermore, the DP73 supports the creation of digital brightfields and fluorescence documentation, and has conference presentation capability, thus providing unrivalled value from the first use.Fine-detail processingNoninvasive ductal carcinoma of the breast by needle biopsy.ISO1600 Sensitivity Delivers Clear Display Even for Faint Fluorescence SignalsImage Taken in 3-CCD Mode (4800 × 3600)Image captured in Standard ModeSubtle Differences in Color Reflected in a Variety of TonesUnparalleled 17.28 Megapixel Resolution■ New 3-CCD Mode Enables Pixel Shifting of 3 Colors for Each PixelA 2.01 megapixel color CCD is combined with pixel-shifting technology to result in the capture of an overwhelmingly high 17.28 megapixel resolution. In addition to conventional 3 x 3 pixel shifting of one color per pixel, the DP73 features a 3-CCD pixel shift mode that enables three-color image resolution (RGB) within a single pixel to improve resolution even more.Rich, Reliable Color Gradations Free from Over or UnderexposureWithout correctionNew Fluorescence Image QualityImproved ResolutionAdvanced Color ReproductionWith correction ■ Achieve Enhanced Fluorescence with High Sensitivity and Low NoiseCapture images across a broad sensitivity range of ISO100-1600 through the incorporation of features including a new CCD drive system, reduced circuit noise and optimized imageprocessing. These technologies also support the capture of bright, sharp fluorescence images with minimal noise.Image Capture that Adjusts for Fluorescence PhotobleachingWithout pixel shift photobleaching correctionWith pixel shift photobleaching correction■ Advanced Algorithm Corrects for Problems of Pixel-shift PhotobleachingConventional Digital cameras that make use of pixel-shifting technology can sometimescompromise images due to changes in brightness that can result from photobleaching during pixel shift. The DP73, however, features a pixel shift photobleaching correction function thatautomatically corrects for changes in gradations of color. So, even if pixel shifting has taken place, the second and subsequent images are captured with histograms identical to the first—resulting in mages that are clear, sharp, and uncompromised.■ WiDER Optimizes Tonal Curves and Gain in Individual Image RegionsSay goodbye to tedious, post-capture image processing with WiDER*—an application that optimizes tonal curves and gain in each region of the image in real time to automatically generate images that have broad dynamic range but are free from under- or overexposure. Efficient and highly effective, this application takes fluorescence imaging methods such as FISH and multi-staining to a whole new level of dynamism.*The function is available in DP73 configurations supportingWiDER.■ Enhanced Color Reproduction in Previously Problematic PortionsThrough supporting AdobeRGB*, the DP73 faithfully renders a broad color gamut. It also features a new color reproduction algorithm, subtle differences in colors that have been difficult to separate until now—such as brown, blue and purple—can be reproduced with exceptional accuracy.*Color reproduction fidelity depends on monitor specifications. Monitors supporting AdobeRGB are required to accurately reproduce images recorded in AdobeRGB mode.Breast cancer cells spiked in peripheral blood.Immunocytochemistry (cytokeratin) and FISH (Her-2 and CEP17) were visualized at the same time. The nuclei was stained with DAPI.A high-power view of gastric mucosa with H. pylori infection.Immunohistochemical features of EML4-ALK fused-gene lung adenocarcinoma, showing cribriform structures and mucin production. Tumor cells are homogeneously positive for ALK antibody (iAEP method: Takeuchi et al. Clin Cancer Res, 15:3143-, 2009)A New Level of Imaging Convenience and FunctionalityDP73 with IX71 configurationDP73 with BX63 configuration■ DP73 configuration examplesTile viewalso provides a full complement of functionsranging from image processing and various typesof measurement to report generation.DAPIP1P2P4Z1++Z2Z3FITCTexasRedMulti-color imageExtended focus image■ High-quality Capture of Multi-color ImagesWith cellSens Standard, the DP73 enableshigh-quality, multi-color composites to be createdfrom multiple images captured at differentwavelengths. cellSens Dimension simplifies theimage capture of multi-stain specimens at differentwavelengths and synthesizes the compositesautomatically.P3■ High-accuracy Alignment forHigh-resolution Macro ImagesWith cellSens Standard, the overlapping parts ofmultiple adjacent images are automaticallyrecognized and the images can be aligned andstitched. Furthermore, cellSens Dimension can beused in combination with the ultrasonic scanningstage of the BX63 motorized microscope toautomatically stitch images together and produceseamless, high-quality macro images made evenbetter through use of the correction function.■ Extended Focus Imaging for Images thatare Entirely In FocusBecause cellSens Dimension enables images tobe captured while varying depth within the sample,sharp focus can be achieved across the entireimage. Images that are entirely in focus can alsobe created from groups of previously capturedimages.cellSens is not for clinical diagnostic use。

相关文档
最新文档