恒美 M-240说明书(2.0)

合集下载

MPI Cable 选择指南说明书

MPI Cable 选择指南说明书

MPI Cable Selection GuideMPI engineers focus to provide on optimal cable solutions taking into account a number of requirements specific for wafer-level measurement systems: optimal cable length, cable weight, magnitude, phase, and temperature stability, design, precision, and manufacturing quality of RF connectors, and the lifetime. As a result, MPI can offer two series of RF cables — the high-end MMC and the standard MRC — covering the entire frequency range starting from 18 GHz. This allows engineers to choose the optimal system configuration in dependence of the required measurement accuracy and budget restrictions. Both cable series are design for use at any MPI system platform, from simple manual TS50 prober and up to advanced automated systems with ShieldEnvironment™ and support testing from -60 °C to +125 °C.FeatureBenefitStandard length of 80 cm and 120 cm• Best integration of test instruments with both manual and automated system platforms • Minimal insertion loss• Maximal convenience of operationSpecial design of the male connectorof both MMC- and MRC-series• EMI-, light-tight and ice-free RF measurements on MPI ShieldEnvironment™ systems• Simple and convenient installation of RF probes on the probe arm• Minimal weight-load of the RF probe arm • Stable and consistent RF contact Multi-step armouring of the connector-cable interface• Optimal heatsink, cable weight and diameter combination • Extended cable lifetime• Easy integration with the RF probe arm Optimized cable diameter • Minimal weight-load of the RF probe • Maximal stability of the RF contact • Integration with ShieldEnvironment™• Shortest thermal equilibrium time Excellent magnitude, phase and temperature stability• Longest time of a valid system calibration High-end RF connectors of MMC-series• Best calibration and measurement results• Longest lifetime of the cable assemblyCable StructureInner ConductorInsulation Outer Conductor (a)Outer Conductor (b)JacketMMC – 110A – MF – 200MMC – 67V / 50Q / 40K – MF – 800MMC-Series VSWR Specification0 20 40 60 80 100 1200 10 20 30 40 50 60 70 801.81.71.61.51.41.31.21.11.0876543210V S W R (d B )A t t e n u a t i o n . dB /mFrequency (GHz)Frequency (GHz)MMC Series Attenuation (at 25°C)MMC-Series Stability Test Results on a Probe SystemConnectors of MMC-Series CablesMagnitude and phase stability are key quality criteria of RF cables. Together with the instrument drift, they define lifetime of the system calibration and therefore, the length of the RF calibration cycle, - the period between two system calibrations. Low-quality cables are sensitive to mechanical stress, like accidental hit by system operator that can happen when modifying settings of measured parameters on the instrument front panel. Such accidental stress of MMC cable was simulated on the wafer-level RF measurement system from MPI and its impact on the measurement error of all S-parameters was calculated using NIST calibration comparison method. Reference experiment was contacted on the same system setup for the high-end industry reference RF cables. The results pro-ved that excellent phase and magnitude stability of the MMC-series RF cables from MPI.Quality of connectors is another distinguishing feature of MMC-series of RF cables. Extremely precise manufactured, with exceptional surface quality and special coating, connectors of MMC-series gua-rantee outstanding electrical characteristics and long lifetime of the entire cable assembly.40 GHz K (2.92 mm), Male MMC connector 67 GHz V (1.85 mm), Male MMC connector 110 GHz A (1.0 mm), Male MMC connector50 GHz Q (2.4 mm), Male MMC connector• MMC – 40K– MF – 1200• MMC – 50Q– MF – 1200• MMC – 110A– MF – 250High-Quality MRC-SeriesMRC-Series characteristics, 18 GHz • MRC – 18SMA – MF – 1200MRC-Series characteristics, 26 GHz • MRC – 26SMA – MF – 1200MRC-Series characteristics, 40 GHz • MRC – 40K – MF – 800MRC-Series characteristics, 50 GHz • MRC – 50Q – MF – xxxxMRC-Series characteristics, 67 GHz • MRC – 67V – MF – 800Product PN keyXXX MFXXX XXXX!800: 80 c m !1200: 120 c mCable Length!Male and Female Connector Gender!18SMA : 18 G Hz, SMA !26SMA : 26 G Hz, SMA+!40K : 40 G Hz, 2.92mm !50Q : 50 G Hz, 2.4mm !67V : 67 G Hz, 1.85mm !110A : 110 G Hz, 1.00mm Frequency, Connector Type!MRC : High-quality cable !MMC: High-end cableCable SeriesOrdering reference MMC-seriesItem DescriptionMMC-40K-MF-80040 GHz precision flex cable 2.92 mm (K) connector, male – female, 80 cm MMC-40K-MF-120040 GHz precision flex cable 2.92 mm (K) connector, male – female, 120 cm MMC-50Q-MF-80050 GHz precision flex cable 2.4 mm (Q) connector, male – female, 80 cm MMC-50Q-MF-120050 GHz precision flex cable 2.4 mm (Q) connector, male – female, 120 cm MMC-67V-MF-80067 GHz precision flex cable 1.85 mm (V) connector, male – female, 80 cm MMC-67V-MF-120067 GHz precision flex cable 1.85 mm (V) connector, male – female, 120 cm MMC-110A-MF-125110 GHz precision flex cable, 1 mm (A) connector, male – female, 12.5 cm MMC-110A-MF-200110 GHz precision flex cable 1 mm (A) connector, male – female, 20 cm MMC-110A-MF-250110 GHz precision flex cable 1 mm (A) connector, male – female, 25 cm Ordering reference MRC-seriesItem DescriptionMRC-18SMA-MF-80018 GHz precision flex cable, SMA connector, male – female, 80 cmMRC-18SMA-MF-120018 GHz precision flex cable, SMA connector, male – female, 120 cm MRC-26SMA-MF-80026 GHz precision flex cable, SMA connector, male – female, 80 cmMRC-26SMA-MF-120026 GHz precision flex cable, SMA connector, male – female, 120 cm MRC-40K-MF-80040 GHz precision flex cable, 2,92 mm (K) connector, male – female, 80 cm MRC-40K-MF-120040 GHz precision flex cable, 2,92 mm (K) connector, male – female, 120 cm MRC-50Q-MF-80050 GHz precision flex cable, 2,4 mm (Q) connector, male – female, 80 cm MRC-50Q-MF-120050 GHz precision flex cable, 2,4 mm (Q) connector, male – female, 120 cm MRC-67V-MF-80067 GHz precision flex cable, 1.85 mm (V) connector, male – female, 80 cm MRC-67V-MF-120067 GHz precision flex cable, 1.85 mm (V) connector, male – female, 120 cmAdaptersHigh-In addition, high-quality RF and high-end mm-wave range adapters are offered to address chal-lenges of regular system reconfiguration with different type of test instrumentation.Waveguide to Coaxial AdaptersElectrical SpecificationPart Number MWA-WR15-1MM MWA-WR12-1MM MWA-WR10-1MM Frequency, GHz50 – 7560 – 9075 – 110 VSWR (Max) 1.4 1.4 1.4 Insertion loss, dB0.350.40.55 Connector 1 mm (male) 1 mm (male) 1 mm (male) Waveguide WR-15WR-12WR-10 RF Adapters• Product PN Key•MRA : RF Adapter•MPA : Precision high-end (Microwave)Adapter•M/F : Male/Female•N : 11 GHz adapter, N•350 : 26 GHz adapter, 3.5 mm•292 : 40 GHz adapter, 2.92 mm•240 : 50 GHz adapter, 2.4 mm•185 : 67 GHz adapter, 1.85 mm•100 : 110 GHz adapter, 1.0 mmMPI Global PresenceDirect contact:Asiaregion:****************************EMEAregion:******************************Americaregion:********************************MPI global presence: for your local support, please find the right contact here:/ast/support/local-support-worldwideSee MPI Corporation‘s Terms and Conditions of Sale for more details.Item DescriptionMRA-NM-350F 11 GHZ RF adapter, N(M)-3.5(F)MRA-NM-350M 11 GHZ RF adapter, N(M)-3.5(M)MPA-350M-350F 26 GHZ precision RF adapter, 3.5(M)-3.5(F)MPA-350F-350F 26 GHZ precision RF adapter, 3.5(F)-3.5(F)MPA-350M-350M 26 GHZ precision RF adapter, 3.5(M)-3.5(M)MPA-292M-240F 40 GHZ precision RF adapter, K(M)-Q(F)MPA-292F-240M 40 GHZ precision RF adapter, K(F)-Q(M)MPA-292M-292F 40 GHZ precision RF adapter, K(M)-K(F)MPA-292F-292F 40 GHZ precision RF adapter, K(F)-K(F)MPA-292M-292M 40 GHZ precision RF adapter, K(M)-K(M)MPA-240M-240F 50 GHZ precision RF adapter, Q(M)-Q(F)MPA-240F-240F 50 GHZ precision RF adapter, Q(F)-Q(F)MPA-240M-240M 50 GHZ precision RF adapter, Q(M)-Q(M)MPA-185M-185F 67 GHZ precision RF adapter, V(M)-V(F)MPA-185F-185F 67 GHZ precision RF adapter, V(F)-V(F)MPA-185M-185M 67 GHZ precision RF adapter, V(M)-V(M)MPA-185M-100F67 GHZ precision RF adapter, V(M)-A(F)RF Adapters•Electrical Specification。

DUO-240中文说明书

DUO-240中文说明书
如果要加快探测器反应速度,就把DIP开关SW-1打到OFF,此时只要有1个脉冲就能触发红外单元。
5.2红外单元步行测试:
1、把微波距离调到MIN(最小)
2、确认DIP开关SW-3打到ON(绿色LED作为步行测试指示灯)。
3、装好探测器的上盖。
4、走入探测器的保护区,观察保护区的边缘。每次触发探测器,绿色LED会闪烁5秒。
划、压、等意外损毁。
B、将底座打开至少1个出线孔,见图3,以2个螺钉、膨胀栓等固定在顶棚的所选位置。
3.3接线:
见图4。
4.2模式选择:
模式DIP开关位于电路板上,如图5。
它控制4个功能,如图5及表2所示。
5.设置
5.1设置红外脉冲计数
如果要最大限度降低误报,就把DIP开关SW-1打到ON,此时必需有2个脉冲才能触发红外单元。
环境要求:
工作温度:-10℃-- 50℃
储藏温度:-20℃-- 60℃
RFI防护:大于30V/M
专利:U.S.5237330(及其他未定专利)
3.2安装
选择适当的安装位置,确保保护区内的主要通道、目标在保护区域内,DUO-240最大安装高度为4.5米。
安装过程:
A、一手握住底座,如图2,另一手旋转上盖,对正缺口,取下上盖,放在安全处,以防
4、调节微波的探测距离(由MIN逐渐向MAX),通过步行测试,确认微波探测距离符合需要。
5、匀速穿过保护区域,确认您的移动被不断探测到。
5.4报警步行测试:
1、DIP开关SW-2和SW-3都打到ON(两个LED的功能都启动)。
2、暂时装好探测器的上盖。
3、从不同距离、不同方向走入探测器的保护区,确认在整个保护范围内的移动都能被探测到(红色LED会亮2-3秒)。

PDH120 240 480+100M系列光端机说明书

PDH120 240 480+100M系列光端机说明书

PDH120/240/480+100M光传输设备用户手册安全使用须知PDH120/240/480+100M系列综合业务传输设备在设计使用范围内具有良好可靠的性能,但仍应避免人为对PDH120/240/480+100M系列综合业务传输设备造成的损害或破坏。

◆仔细阅读本手册,并保存好本手册,以备将来参考用;◆不要将设备放置在接近水源或潮湿的地方;◆不要在电源电缆上放任何东西,不要将电缆打结或包住,并应将其放在不易碰到的地方;◆电源接头以及其它设备连接件应互相连接牢固,请经常检查;◆连接电源线时,务必认真按接线柱标注接线;所用电源必须满足如下条件:1.直流-48V机种:-36V ~-72V2.交流220V机种:220V±20%,50Hz◆请注意设备清洁,必要时可用软棉布擦拭;◆不要堵塞通风口;◆在下列情况下,请立即断开电源,并与公司联系:1.设备进水;2.设备摔坏或机壳破裂;3.设备工作异常或展示的性能已完全改变;4.设备产生气味、烟雾或噪音。

◆请不要自己修理设备,除手册中有明确指示外。

一、概述PDH120/240/480+100M系列综合业务传输设备是本公司使用自主开发的专用集成电路研制生产的综合业务传输设备。

它将标准的2M传统TDM业务接口、V.35业务接口与10/100BaseTx以太数据业务接口融为一体,并转变为高速光信号,在光纤上进行传输,同时支持双光路1+1无损保护,从而使高速数据业务和传统TDM业务在同一对光纤上传输成为可能,以最小的成本满足用户对高速数据业务和传统TDM业务综合接入的需求。

PDH120/240/480+100M系列综合业务传输设备维护简单,开电即用,还可提供集中式局端设备,并提供完整的网络管理功能。

二、主要特点◆E1数字口阻抗75Ω/120Ω可选;◆以太接口均为10/100Base-Tx自适应,带宽可以0.5M为单位调整,最大带宽100M;◆E1通道支持内置BERT(Bit Error Rate Test);◆提供1个公务话机接口;◆提供1个RS232异步数据接口;◆提供1个管理接口,可实现集中监控,并支持系统升级;◆提供一组控制开关,用于设置设备维护测试;◆双光路光端机可实现业务的1+1无损保护;◆采用大规模芯片,电路简单,功耗低,可靠性高;◆适应多种电源环境,-48VDC或220V AC;◆标准1U机框,体积小,重量轻,工作稳定可靠,安装方便。

1600kg客梯2.0速度设计计算书

1600kg客梯2.0速度设计计算书

TKJ1600/2.0-JXW/VVVF 交流变频乘客电梯设计计算书电梯2010年10月20日目录1 电梯型号 (1)2 主要参数 (1)3 曳引驱动计算 (1)3.1 曳引电动机功率计算 (1)3.2 轿厢面积计算 (1)3.3 轿厢通风面积的计算 (2)3.4 曳引轮输出额定扭矩 (2)3.5 主轴最大静载荷 (2)3.6 悬挂绳安全系数计算 (2)4 导轨承载计算 (4)5 曳引条件计算 (4)6 结构计算 (5)7 缓冲器的验算 (7)8 安全钳选用 (7)9 限速器的选用 (7)10 底坑空间和顶层空间计算 (8)11 紧急救援措施 (9)12 超速及其它保护装置的说明资料 (9)13 导轨的说明资料 (12)14 轿厢和门系统的说明资料 (12)15 轿门护脚板 (13)16 门系统说明资料 (13)17 机械部件的防护 (14)18 电梯整机性能指标 (14)19 样梯可靠性运行记录和总结 (15)1 电梯型号TKJ1600/2.0-JXW/VVVF 交流变频乘客电梯2主要参数载重量:Q=1600kg 运行速度:V=2.0m/s 提升高度:H=53.1米曳引比:I=2:1曳引包角:α=180˚轿厢自重:P=1200㎏3 曳引驱动计算3.1曳引电动机功率计算:取平衡系数Φ=0. 45 取η=0.85计算公式: P=QV(1-Φ)=1600×2×(1-0. 45)=20.3KW 102ŋ102×0. 85选用蜗轮蜗杆曳引机,额定功率P1=22KW, 所以适用。

曳引轮节径D1=400mm曳引绳根数m=7,直径d=Φ10mm,额定转速n=191r/min 上开口角r=35°下部切口角β=90°额定速度验算:η1=60×2×2/(3.14×0.5)=152г/min 适用3.2轿厢面积计算轿厢净宽A=1900mm,轿厢净深B=1800mm轿厢有效面积S=1.9×1.8=3.42m2标准五吨轿厢面积为3.56 m2所以本电梯不超标共15 页第 1 页3.3轿厢通风面积的计算轿厢通风面积不应小于轿厢有效面积的1%,即均为0.02 m2 S下+S下=0.27×0.045+(1.35×2+1.4)×0.005=0.032 m2>0.02m2 所以上下部的通风面积足够3.4.曳引轮输出额定扭矩M1M1= 9550×22×2×0.85=2349(N·m)152实际运行扭矩M2按超载10%计算M2= (1.1-0.45)×1600×20.3×0.4=2111 N·m< M1所以满足2×23.5.主轴最大静载荷T曳引绳Φ10质量q=0.34㎏/m 曳引绳根数m=5T= 1200+1.25×1600 +7×0.34×53.1+1200+1600×0.45+2.85×132 2=2614㎏<曳引机允许静载荷,所以通过3.6.悬挂绳安全系数计算K P=4=1β=90°Nequiv( t )=5Nequiv(P)= 3Nequiv= 5+3=8共15 页第 2 页许用安全系数S f=10×(2.6834- )=17Φ10最小破断力T K=44000N安全系数S=44000×7/[(1200+1600)/2+53.1×7×0.34]×9.8=2121>17 所以满足共15 页第 3 页4.导轨承载计算(按中心导向安全钳动作为最严重工况)轿厢导轨T89/B材料抗拉强度370Mpa,截面积A=15.7cm2i x=1.98cm i y =1.84cm 导轨与等距L K=200cmI x =59.7 cm4I y =53cm4W x =14.5cm3W y =11.9cm3轿厢导靴间距h=3350 轿厢尺寸宽A=1.9m深B=1.8m导轨许用应力δporm =205Mpa 最大允许变形[δy ]为5mm细长比λ=LK/ίx=200/1.98=101.01 查表得ω=1.9 K=2F K = [K×(P+Q) g]/2= [2×(1200+1600)×9.8]/2=27440N压弯应力δK=(F K×w)/A=27440×1.9/(15.7×102)=33.2Mpa 载荷偏心距X Q=B /8=1800/8=225mm Y Q=0F x=(3×9.8×1600×225)/(2×3350)=1579NM y=(3F x×Lk)/16=(3×1579×2000)/16=592125Nmm弯曲应力δy =My/Wy=592125/(11.9×103)=49Mpa挠度δx =0.7×(F x×L K3)/(48×E×I y)=(0.7×1579×2003)/(48×2×107×108)=0.085cm =0.85mm以上均通过,符合要5.曳引条件计算5.1按125%额定载荷轿厢位于最底层装载静态工况计算。

MOXA IA240系列Arm基础200MHz工业计算机产品介绍说明书

MOXA IA240系列Arm基础200MHz工业计算机产品介绍说明书

IA240SeriesArm-based192MHz industrial computer with2LAN ports,4serial ports,4DIs,4DOsFeatures and Benefits•MOXA ART32-bit Arm9industrial processor•64MB RAM,16MB flash onboard•4RS-232/422/485serial ports•4digital input and4digital output channels(TTL signal)•Dual10/100Mbps Ethernet ports•SD slot for storage expansion•Ready-to-run Linux kernel2.6platform•Unique patented software encryption lock•Installation options:DIN-rail,wall-mount(with accessory)•Robust,fanless design,IP30protection mechanism•-40to75°C wide-temperature models availableCertificationsIntroductionThe IA240embedded computers are designed for industrial automation applications.The computers feature4RS-232/422/485serial ports,dual Ethernet ports,4digital input channels,4digital output channels,and an SD slot in a compact,IP30-protected,industrial-strength rugged housing. The IA240’s vertical DIN-rail form factor makes it easy to install the computers in a small cabinet.This space-saving solution also facilitates easy wiring,making the IA240a great choice as a front-end embedded controller for industrial applications.Wide-temperature models of the IA240are also available.The IA240-T model can operate reliably in a temperature range from-40to75°C,making it appropriate for harsh industrial automation environments.The industrial design of the IA240provides a robust,reliable computing platform.Due to their Arm-based architecture,the IA240computers will not generate a lot of heat,making them ideal for industrial automation environments.AppearanceFront View Top ViewSpecificationsComputerCPU MOXA ART Arm9,192MHzStorage Slot SD slots x1Supported OS Linux kernel version2.6MemoryFlash16MBSDRAM64MBComputer InterfaceEthernet Ports Auto-sensing10/100Mbps ports(RJ45connector)x2 Serial Ports RS-232/422/485ports x4,software selectable(RJ45) USB2.0USB2.0hosts x1,type-A connectorsDigital Input DIs x4Digital Output DOs x4Digital InputsConnector Screw-fastened Euroblock terminalVoltage Logic0:0-0.8VLogic1:2.0-5.5VDigital OutputsConnector Screw-fastened Euroblock terminalCurrent Rating24mA per channelVoltage Logic0:0-0.55VLogic1:2.5-3.3VEthernet Interface10/100BaseT(X)Ports(RJ45connector)2Magnetic Isolation Protection 1.5kV(built-in)USB InterfaceStorage Port USB Type AUSB Standards USB1.1/2.0compliantLED IndicatorsSystem Power x1System Ready x1LAN2per port(10/100/1000Mbps)Serial2per port(Tx,Rx)Serial InterfaceBaudrate50bps to921.6kbps(supports non-standard baudrates)Connector8-pin RJ45Console Port RS-232(TxD,RxD,GND),8-pin RJ45(115200,n,8,1)Data Bits5,6,7,8Flow Control RTS/CTS,XON/XOFF,ADDC®(automatic data direction control)for RS-485,RTSToggle(RS-232only)ESD Protection4kV,for all signalsNo.of Ports4Parity None,Even,Odd,Space,MarkRS-485Data Direction Control ADDC®(automatic data direction control)Serial Standards RS-232/422/485Stop Bits1,1.5,2Serial SignalsRS-232TxD,RxD,RTS,CTS,DTR,DSR,DCD,GNDRS-422Tx+,Tx-,Rx+,Rx-,GNDRS-485-2w Data+,Data-,GNDRS-485-4w Tx+,Tx-,Rx+,Rx-,GNDPower ParametersInput Current300mA@24VDCInput Voltage12to48VDCNo.of Power Inputs1Power Connector3-pin terminal blockPower Consumption7W(max.)Physical CharacteristicsHousing MetalDimensions60x137x100mm(2.36x5.39x3.94in)Weight430g(0.96lb)Installation DIN-rail mounting,Wall mounting(with optional kit)Environmental LimitsOperating Temperature IA240-LX:-10to60°C(14to140°F)IA240-T-LX:-40to75°C(-40to167°F)Storage Temperature(package included)IA240-LX:-20to80°C(-4to176°F)IA240-T-LX:-40to85°C(-40to185°F)Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsEMC EN55032/24,EN61000-3-2Class A,EN61000-3-3,EN61000-6-2/-6-4 EMI CISPR32,FCC Part15B Class AEMS IEC61000-4-11DIPsIEC61000-4-2ESD:Contact:4kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:3V/mIEC61000-4-4EFT:Power:1kV;Signal:0.5kVIEC61000-4-5Surge:Power:1kVIEC61000-4-6CS:150kHz to80MHz:10V/m;Signal:10V/mIEC61000-4-8PFMFSafety EN60950-1,IEC60950-1,UL60950-1Vibration IEC60068-2-6DeclarationGreen Product RoHS,CRoHS,WEEEMTBFTime425,321hrsStandards Telcordia(Bellcore),GBWarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x IA240Series computerInstallation Kit1x DIN-rail kit1x wall-mounting kitCable1x DB9male to RJ458-pin1x Ethernet,crossover1x RJ45-to-DB9console cable1x terminal block to power jack converterPower Supply1x power adapter,universalDocumentation1x document and software CD1x product certificates of quality inspection,Simplified Chinese1x product notice,Simplified Chinese1x quick installation guide1x warranty cardDimensionsOrdering InformationModel Name Serial Ports LAN Ports DI/DO USB2.0Storage Slots Operating Temp. IA240-LX424/41SD Card-10to60°CIA240-T-LX424/41SD Card-40to75°C ©Moxa Inc.All rights reserved.Updated Jan22,2020.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。

SCA系列接口连接器240系列(SCA.1)说明书

SCA系列接口连接器240系列(SCA.1)说明书

s MATERIALSs SPECIFICATIONSsFEATURES•Half pitch connector conformed to SCA system (80pins).•Add mating guide and ESD protection to do plug-in safety and reliability (They are newly added on SCA.2CN).•Hot-plugging. Ground contacts mate first before other contacts mate when engagement is done (conforms to SCA.2 specification).•To prevent pin-bending, bellows contacts are used.•Plug: 2 types are available.1)The center of a SMT plug mates the center of a PCB.2)0.9 mm (0.035 in.) off-set from centerSpecifications–55°C to +105°C DC 1 A AC 240 V40 m Ω max. (DC 6 V, 0.1 A)1000 M Ω min. (DC 500 V)AC 750 V for 1 minuteItemOperating temperature range Current rating Voltage rating Contact resistance Insulation resistance Dielectric withstand voltage )ItemInsulator Conductor PlatingMaterialsPolyester (UL94V-0)Copper alloy Contact TerminalGold plating Palladium platingSCA.1, SCA. 2 INTERFACE CONNECTOR240 SERIES (SCA)DiscontinuedPLUG, SMT (STRADDLE MOUNT)sDIMENSIONSs PC BOARD MOUNTING PATTERNs PART NUMBERFCN-248Q080-L/BSPLUG, SMT [0.9 mm (0.035 in.) OFFSET]sDIMENSIONSs PART NUMBERFCN-248Q080-L/CSSOCKET, VERTICAL MOUNT s DIMENSIONSs PC BOARD LAYOUTs PART NUMBERFCN-244B080-G/ASPLUG, SMT (STRADDLE MOUNT), 20 PIN s DIMENSIONSs PC BOARD LAYOUTs PART NUMBERFCN-248Q020-L/ESs DIMENSIONS 80 -Ls PC BOARD LAYOUTPLUG, SMT (STRADDLE MOUNT) FIBER CHANNEL sDIMENSIONSs PART NUMBERFCN-248Q040-L/ES248Q Series SCA.2SINGLE SIDE SMT SCA.2s DIMENSIONSs PC BOARD LAYOUTs PART NUMBERFCN-248Q080-L/FSSOCKET, VERTICAL MOUNT FIBER CHANNEL sDIMENSIONSBW P D E D N E M M O C E R SS E N K C I H T R E B M U N T R A P T C A T N O C L A N G I S )A (H T G N E L T S O P T C A T N O C D S E )H G E L T S O P B (T N m m 8.0:T P S C /L -040B 442-N C F )470.0(88.1)470.0(88.1m m 6.1:T P S B /L -040B 442-N C F )011.0(97.2)601.0(07.2m m 0.2:T P S D /L -040B 442-N C F )321.0(21.3)321.0(21.3m m 4.2:T P S E /L -040B 442-N C F )421.0(41.3)631.0(54.3mm 2.3:T P SF /L -040B 442-N C F )061.0(60.4)861.0(72.4SOCKET, VERTICAL MOUNTs DIMENSIONSs PC BOARD MOUNTING PATTERN© 2007 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the prop-erty of their respective owners. Fujitsu Components America, Inc. or its affiliates do not warrant that the content of the datatasheet is error free. In a continuing effort to improve our products, Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets witout prior notice. Rev. November 2, 2007.JapanFujitsu Component Limited Gotanda-Chuo Building3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141-0022, Japan Tel: (81-3) 5449-7010Fax: (81-3) 5449-2626Email:********************.com Web: North and South AmericaFujitsu Components America, Inc.250 E. Caribbean DriveSunnyvale, CA 94089 U.S.A.Tel: (1-408) 745-4900Fax: (1-408) 745-4970Email:*********************.com Web: /componentsEuropeFujitsu Components Europe B.V.Diamantlaan 252132 WV Hoofddorp NetherlandsTel: (31-23) 5560910Fax: (31-23) 5560950Email:*****************.comWeb: /components Asia PacificFujitsu Components Asia Ltd.102E Pasir Panjang Road#01-01 Citilink Warehouse Complex Singapore 118529Tel: (65) 6375-8560Fax: (65) 6273-3021Email:*****************.com Fujitsu Components International Headquarter Offices。

Volvo 240 Turbo 发动机技术参数说明说明书

Volvo 240 Turbo 发动机技术参数说明说明书
Tillverkare/M ake_ Volvo
.Model I/Model
---2--4--0----T---u- r:-b---o--- ------------^iNr/iNn
,j I.J
«!
M O T O R /E N G IN E
65) Cylinderdiameter Bore
92 mm
60 1
115) A n ta l sittp la ste r__________ 5 _________________ Seating capacity
116) V ik t ____ 1 2 7 5 k g Weight
TILLBEHÔR OCH SÀTEN/ACCESSDRIES A N D UPHOLSTERY
sv:
IH - .
•^ T i r \ c
F.l.S.A. )
flUTOW
1196 mm
42. Steering ra tio
17,3:1
61. Thickness o f brake d is c , fro n t:
22,0 mm; re ar: 9,6 mm
62. Diameter of brake d is c , fro n t:
263 mm; re ar: 281 mm
T n fp g ra l
73) Antal ramlager for vevaxein
5
Number of crankshaft main bearings
69) Max. tillâten slagvolym Max. cylinder capacity allowed
71) Antal
1
Number

COMMTEST220和COMMTEST240数据收集器系统用户指南说明书

COMMTEST220和COMMTEST240数据收集器系统用户指南说明书

DescriptionCOMMTEST220and COMMTEST240are portable datacollector solutions that cater to non-hazardous environments.You can use these small form-factor,rugged devices to takevibration recordings and upload the collected data for detailedanalysis in System1*.The data collectors work in tandem with the S1Collector appwhich runs on an industrial smartphone hand-held device.Youcan collect vibration data,take pictures,send text messages,check your email,make phone calls and run other apps all onthe same hand-held device.The data collectors use Bluetooth to communicate with thehand-held device.The S1Collector app exchanges data withSystem1*using Wi-Fi,a cellular network,or a USB cable.You can set up your routes in System1*and sync up the datawith the app using remote communication servers.The industrial hand-held device eliminates the need for a PCor other software packages at the data collection site.It is theonly device you need to receive routes and send collected datafrom the field.You can take recordings from a predefined route as well asoff-route recordings that are not part of a route sequence.Off-route recordings may be necessary if a machine's vibrationpattern does not meet your expectations.The data collectors have a neck strap with Sensor Keeperwhich restrains your sensor while you walk or climb to reachother machines.The neck strap also has detachable safetybreakaways to protect you in case the cables are caught inrotatingmachinery.COMMTEST220&COMMTEST240Product DatasheetBently Nevada*Asset Condition MonitoringDocument:109M0792Document:109M0792Document:109M0792Document:109M0792Handheld Specificationsecom®Smart-Ex201-A Part Number111M5756ecom®Smart-Ex201-E Part Number109M8034Display 4"Gorilla Glass2 Glove touchMobile 4G/LTEQuad Band UMTS and GSMWiFi 802.11a/b/g/n Dual band WiFi Direct WiFiHotspotBlueTooth 4.0and LECameras 8MP back 1MP frontLight Camera flash LED torchSensors GPS NFCOS Android5.1CPU Quad core1.2GHzMemory 1GB RAM16GB internal storageBattery Li-Ion4800mAhUp to40hr talk timeSize 137x72x21mm 290gRuggedness IP68-20to55°CFor the latest specifications and ratings of these industrial hand-held devices,visit.The COMMTEST220and COMMTEST240 solutions include an industrial hand-held device that runs the Android operating system and uses USB,cellular,Bluetooth and Wi-Fi for communication.These solutions have features that reduce but do not eliminate cybersecurity risks.We strongly recommend implementing additional cybersecurity protections such as the following:n Controlling user accessn Scanning for virusesn Applying timely updatesn Encrypting datan Using mobile device management softwareThe recommended measures are at your discretion and responsibility.Some residual risk may remain.For more information on cybersecurity,see SCOUT200Series Installation and Operation Manual(109M1269-01).Document:109M0792For a detailed list of country and product-specificapprovals,refer to the Approvals Quick ReferenceGuide(108M1756)at .COMMTEST220-AXX-BXXA:Handheld Options00None01ecom Smart-Ex201-A(North America)02ecom Smart-Ex201-E(Europe)03Tab Active tabletB:Data Collector Approval Options00NoneThe overall hazardous system rating is defined by theminimum rating of the data collector,industrialhandheld and accessories.Metrology certification is available with yourorder.Basic KitWe offer COMMTEST220in a basic kit with theoption to purchase the System1*software andlicense separately.Additional accessories arealso available.Document:109M0792COMMTEST240-AXX-BXXA:Handheld Options00None01ecom Smart-Ex201-A(North America)02ecom Smart-Ex201-E(Europe)03Tab Active tabletB:Data Collector Approval Options00NoneThe overall hazardous system rating is defined by theminimum rating of the data collector,industrialhandheld and accessories.Metrology certification is available with yourorder.Basic KitWe offer COMMTEST220in a basic kit with theoption to purchase the System1*software andlicense separately.Additional accessories arealso available.Document:109M0792Language Specific Warning Labels110M9913Magnet base label110M9914Sensor keeper side label110M9915Sensor keeper front label111M7144Hard carrying case label Optional Accessories3071/01System1*software and license109M2387Handheld,battery-powered laser Tach for IS Zone1This item does not include a cable.You must order part number109M2389.109M2389 1.2-meter laser Tach cable for109M2387109M2391Laser Tach powered by SCOUT220-IS& SCOUT240-ISCBL502165-meter laser Tach cable for109M2391113M5529-01Reflective tapeOne roll,60cm(23.7in)111M5756ecom®Smart-Ex01-A109M8034ecom®Smart-Ex01-E113M9352-01ecom®TAB-EX US/EU113M9352-02ecom®TAB-EX AS/NZ113M9353-01Tab Active tabletDocument:109M0792Copyright2000-2018Baker Hughes,a GE Company,LLC("BHGE")All rights reserved.*Denotes a trademark of Bently Nevada,LLC,a wholly ownedsubsidiary of Baker Hughes,a GE company,a wholly ownedsubsidiary of Baker Hughes,a GE company.All product and company names are trademarks of their respectiveholders.Use of the trademarks does not imply any affiliation with orendorsement by the respective holders.The information contained in this document is subject to changewithout prior notice.1631Bently Parkway South,Minden,Nevada USA89423Phone:Document:109M0792。

光子美容机控制系统使用说明-(240-128)-新控制器[1]

光子美容机控制系统使用说明-(240-128)-新控制器[1]
光子美容机控制软件操作说明
功能特点
5英寸蓝色背光液晶显示器
支持双光头输出设计
光头自动选择
水温检测,水位检测接口
极强的抗干扰能力设计
光头独立计数设计
多种治疗模式选择
自带时间显示
中英文语言切换
图形化的操作界面
软件操作说明
1.欢迎界面
(图一)
开启设备总电源开关,屏幕显示欢迎界面及自检进度条,如图一所示,大约2秒钟后进入治疗模式选择界面。
11.Factory Setting:
工程相应的语言是否被显示,选择no则不被选中,选择yes则被选中。
6.专业模式
本控制系统具有专业模式,可以使用更多的治疗模式进行治疗。
具体方法:在系统上电前按住最左边的按键,系统上电等待六秒钟,进入工程模式菜单,选择第九项,如图十一。
可调整的选项参数一共有11项(图示见图十):
1.Reset HR Counter:
清除脱毛光头的计数器;
2.Reset SR Counter:
清除嫩肤光头的计数器;
3.System Reset:
系统治疗参数复位;
4.Water Current Checking:
水流检测功能选项,YES为开启,NO为关闭;
电源充电
(图三)
在选择相应的治疗模式后,按“ENTER”键,电源进行充电,如图三所示,电源充电结束后,系统自动进入治疗界面,如图四。
3.治疗界面
(图四)
系统充电完成后,进入治疗界面,如图四所示,在治疗界面中,我们可以进行治疗参数的调整。按“SIMM”键可直接退出治疗画面,关闭光头,按“ENTER”键可返回“治疗模式选择菜单”选择其他治疗模式。
7.Chargeing UpChecking:

易 Modicon M200 TM200CE40R 逻辑控制器数据表说明书

易 Modicon M200 TM200CE40R 逻辑控制器数据表说明书

Product datasheetCharacteristicsTM200CE40Rcontroller M200 40 IO relay+EthernetMainRange of productEasy Modicon M200Product or component type Logic controller [Us] rated supply voltage 100...240 V AC Discrete I/O number 40Discrete input numberI2...I5: 4 fast inputI0, I1, I6, I7: 4 high speed input I8...I23: 16 regular input Discrete output number 16 relay Discrete input voltage 24 V Discrete input voltage type DCDiscrete input current 7 mA for inputDiscrete input logic Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2Discrete output voltage 24 V DC 220 V AC Discrete output current 2 ADiscrete output type Relay normally openPower consumption in VA59…69 VA at 100...240 V AC (with max I/O)ComplementaryMaximum number of I/O expansion module4 with 128 discrete output(s) for transistor output 4 with 80 discrete output(s) for relay output Supply voltage limits 85…264 V Network frequency 50/60 Hz Inrush current50 AVoltage state 1 guaranteed >= 15 V for input Voltage state 0 guaranteed <= 5 V for inputInput impedance 3.3 kOhm for discrete inputResponse time5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed inputi s c l a i m e r : T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s100 µs turn-off, I2...I5 terminal(s) for fast input35 µs turn-on, I2...I5 terminal(s) for fast input100 µs turn-off, I8...I13 terminal(s) for regular input35 µs turn-on, I8...I13 terminal(s) for regular input10 ms turn-off, Q0...Q15 terminal(s) for relay output10 ms turn-on, Q0...Q15 terminal(s) for relay output125 µs turn-off, I14...I23 terminal(s) for regular input55 µs turn-on, I14...I23 terminal(s) for regular inputConfigurable filtering time0 ms for input3 ms for input12 ms for inputOutput voltage limits30 V DC250 V ACMaximum current per output common4 A at COM 24 A at COM 04 A at COM 14 A at COM 3Electrical durability100000 cycles AC-12, 240 V, 480 VA, resistive100000 cycles DC-12, 24 V, 48 W, resistiveSwitching frequency0.1 Hz with maximum loadMechanical durability20000000 cycles for relay outputMinimum load10 mA at 5 V DC for relay outputMemory capacity512 byte internal flash for backup of programsData storage equipment32 GB micro SD card (optional)Battery type BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)Backup time 3 years at 25 °C (by interruption of power supply)Execution time for 1 KInstruction0.3 ms for event and periodic taskExecution time per instruction0.2 µs BooleanExct time for event task60 µs response timeClock drift<= 90 s/month at 25 °CRegulation loop Adjustable PID regulator up to 14 simultaneous loopsControl signal type Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode)Pulse/direction at 100 kHz for fast input (HSC mode)Single phase at 100 kHz for fast input (HSC mode)CW/CCW at 100 kHz for fast input (HSC mode)Counting input number 4 fast input (HSC mode) at 100 kHz 32 bitsIntegrated connection type USB port with mini B USB 2.0 connectorNon isolated serial link serial 1 with terminal block connector and RS485 interfaceNon isolated serial link serial 2 with terminal block connector and RS232/RS485 interfaceEthernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interfaceIsolated serial link serial 2 with terminal block connector and RS485 interfaceTransmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS23212 Mbit/s for USB10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IPCommunication port protocol USB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-NetworkEthernet Modbus TCP/IP: Modbus TCP/IP client/serverLocal signalling 1 LED (green)PWR:1 LED (green)RUN:1 LED (red)module error (ERR):1 LED (green)SD card access (SD):1 LED (red)BAT:1 LED (green)SL1:1 LED per channel (green)I/O state:2 LEDs (green)communication (LK/ACT 10/100):Electrical connection Mini B USB 2.0 connectorfor a programming terminalRJ45 connectorfor connecting Ethernet networkremovable screw terminal blockfor inputsremovable screw terminal blockfor outputsremovable screw terminal block, 4 terminal(s) for connecting the serial link1removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supplyMaximum cable distance between devices Unshielded cable: <50 m for input Shielded cable: <10 m for fast input Shielded cable: <10 m for high speed inputUnshielded cable: <150 m for outputInsulation Non-insulated between inputsBetween output and internal logic at 1780 V ACBetween output groups at 1780 V ACBetween supply and internal logic at 1780 V ACBetween input and internal logic at 500 V ACBetween fast input and internal logic at 500 V ACBetween input groups at 500 V ACSensor power supply24 V DC at 300 mA supplied by the controllerMarking CEMounting support Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715Height90 mmDepth70 mmWidth175 mmNet weight0.512 kgEnvironmentIP degree of protection IP20 with protective cover in placeProduct certifications RCMIACS E10CSACULusStandards EN/IEC 61010-2-201EN/IEC 61131-2Electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC61000-4-2Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC61000-4-2Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to EN/IEC61000-4-3Magnetic field at power frequency - test level: 30 A/m conforming to EN/IEC 61000-4-8Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to EN/IEC61000-4-4Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to EN/IEC61000-4-4Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to EN/IEC61000-4-41.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC61000-4-51.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to EN/IEC61000-4-51.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to EN/IEC 61000-4-51.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to EN/IEC 61000-4-51.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to EN/IEC61000-4-51.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to EN/IEC61000-4-51.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to EN/IEC61000-4-5Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to EN/IEC61000-4-4Shock resistance15 gn for 11 ms30 gn for 6 msImmunity to microbreaks10 msVibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail1 gn at 8.4…150 Hz on symmetrical rail3.5 mm at 5…8.7 Hz on panel mounting2 gn at 8.7…150 Hz on panel mountingRelative humidity10…95 %, without condensation (in operation)10…95 %, without condensation (in storage)Ambient air temperature for operation0…55 °C (horizontal installation)Ambient air temperature for storage-25…70 °CPollution degree<= 2Operating altitude0...2000 mStorage altitude0…3000 mPacking UnitsPackage 1 Weight7.400 kgPackage 1 Height9.000 cmPackage 1 width18.400 cmPackage 1 Length13.800 cmOffer SustainabilitySustainable offer status Green Premium productEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)EU RoHS DeclarationMercury free YesRoHS exemption information YesChina RoHS Regulation China RoHS declarationEnvironmental Disclosure Product Environmental ProfileCircularity Profile End of Life InformationWEEE The product must be disposed on European Union markets following specific waste collection andnever end up in rubbish binsDimensions DrawingsDimensions Drawings DimensionsMounting and ClearanceMounting and Clearance Mounting on a RailDirect Mounting on a Panel SurfaceMounting PositionClearanceTMCR2•••InstallationTMCR2••• De-InstallationProduct datasheetTM200CE40R Connections and SchemaWiring Diagram / Connections SchemaAC Power Supply(*)Type T fuseDigital Inputs Positive Logic (Sink)(*)Type T fuse(**)Fast inputs(1)The COM0 and COM1 terminals are not connected internally.Digital Inputs Negative Logic (Source)(*)Type T fuse(**)Fast inputs(1)The COM0 and COM1 terminals are not connected internally.Relay Outputs - Negative Logic (Sink)(*)Type T fuse(1)The COM0 and COM1 terminals are not connected internally.(2) A free wheeling diode or an RC snubberRelay Outputs - Positive Logic (Source)(*)Type T fuse(1)The COM0 and COM1 terminals are not connected internally.(2) A free wheeling diode or an RC snubberEthernet ConnectionUSB Mini-B ConnectionSL1 ConnectionD1 :D1 (A+)D0 :D0 (B-)Shield :ShieldCOM :O V ComProduct datasheetTM200CE40R Performance CurvesDerating CurvesRelay OutputsX :Ambient temperature (°C / °F)Y :Output load current (%)。

E+H MicroPilot HART M FMR240 雷达物位计简明操作指南

E+H MicroPilot HART M FMR240 雷达物位计简明操作指南
3 接线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 在 F12/F23 外壳中接线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3.2 在 T12 外壳中接线 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.3 接线端子分配 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.4 连接测量单元 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.5 屏蔽 / 电势平衡 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.6 防护等级 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.7 连接后检查 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

iSitePower-M系列产品说明书

iSitePower-M系列产品说明书

iSitePower-M-5/10/15/20/25/3024 hours power supplySafe &ReliableLithium Iron Phosphate (LFP)CellCell Level Monitoring Port 0V VoltageBuilt-in Extinguish BagHigh quality ExperiencePower ModuleBattery Module2.5 kW ∣5 kWh 5 kW ∣10 kWh 5 kW ∣15 kWhSleep-level Noise One app for All Control100% Depth of Discharge Pack Level Energy OptimizationSystem SpecificationsPower moduleiSitePower-M-MAP05A1Output/input power per module 2.5 kWBattery module iSitePower-M-MAB05B1Battery module energy 5kWh Number of power modules 1Number of batterymodules 123456Battery usable energy 15kWh 10kWh 15kWh 20 kWh 25 kWh 30 kWh Max. output power2.5kW5kW5kW5 kW5 kW5 kWGeneral SpecificationPower module dimension (W*H*D)700 * 246 * 152 mmPower module weight17 kgBattery module dimension (W*H*D)700 * 390 * 158 mmBattery module weight50 kgBase dimension (W*H*D)700 * 65 * 147 mm (floor installation)643 * 110 * 176 mm (wall-mounted installation)Base weight 1.5 kg (floor installation)5.5 kg (wall-mounted installation) Installation Mode Wall-mounted/ground-mountedProtection rating IP 66Cell technologyLithium-iron phosphate (LiFePO4)CommunicationDisplay SOC status indicatorCommunicationCAN (Parallel communications for power modules / Parallel communications between the batterymodule and power module / Communications for battery modules)Connect to Smart PVMS in WLAN/FE/4G communication modeSmart String Energy Storage System1.Test conditions:100%depth of discharge (DoD),0.2C rate charge & discharge at 25℃,at the beginning of life.If no PV modules are installed or the system has not detected sunlight for at least 24 hours, the minimum end of discharge SOC is 15%.2.The weight of the battery module is subject to the actual product,with a tolerance of ±3%3.Refer to battery warranty letter for conditional application.4.Improper storage system installation may compromise product warranty and operation safety. Please follow the user manual during the installation, use, and maintenance of the storage system.PV inputMPPT voltage range90-420 V DC Maximum input capacity of the MPPT 5.5 kWp PV string quantity2 strings Number of MPPT channels1 channel Maximum input current for one string 12.5 A Maximum short circuit current for one string 18 ALightning protectionCommon mode (between PV+/PV –pair and PE): ±10 KA; 8/20 μsAC outputOutput voltage system Single-phase 200/208/220/230/240 V AC. The default value is 220 V ACOutput frequency 50/60 Hz. The default value is 50 Hz.Maximum output current 30 A Output power 6 kVA/5 kWPower factor0.8Overload capacity102% ≤ Load ≤ 125%30 s 125% < Load ≤ 150%10 s >150%/short circuit0.3 sAC parallel boxDimensions (W * H * D)350 mm x 450 mm x 150 mmWeight Approx. 12 kgInput voltage 200/208/220/230/240 V AC. The default value is 220 V AC.Input current Max.90 AOutput voltage 200/208/220/230/240 V AC. The default value is 220 V AC.Output current Max.90 ACable outlet mode Bottom in and bottom outInstallation Mode Wall-mounted or pole-mounted installationDegree of protectionIP55Environmental parametersOperating temperature 0°C to 45°C Relative humidity 5%-95% (RH)Altitude Requirements0~4000 m (The operating temperature decreases by 1℃per 200 mwhen the altitude is 2000 m to 4000 m)AC inputInput voltage 200/208/220/230/240 V ACInput current Max.30 A Frequency50/60 Hz Maximum bypass input power 6 kWLightning protectionDifferential mode (between live and neutral): 3 KA; 8/20 μsCommon mode (between live or neutral and PE, between live/neutral pair and PE): 5 KA; 8/20 μsCompliance informationCertificationsIEC62920:2017, CISPR11: 2015+A1: 2016/EN55011: 2016+A1: 2017, EN62040-2, ETSI EN 301 489-1, ETSI EN 301 489-17, IEC61000-3,IEC 62619, IEC 62109-1, IEC 62109-2, RoHS, EN 50385, RCM, UKCA,ICE 60730, UN38.3Copyright © Huawei Technologies Co., Ltd. 2022. All rights reserved.No parts of this document may be reproduced or transmitted in any form or by any meanswithout prior written consent of Huawei Technoligies Co., LtdTrademark Notice, HUAWEI and are trademarks or registered trademarks of Huawei Technoligies Co., Ltd.Other trademarks ,product ,service and company names mentioned are the property of their respective owners.General DisclaimerThe information in this document may contain predictive statement including, without limitation, statements regardingthe future finacial and operating results, future product portfolio,new technology, etc. There are a number of factors thatcould cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.Huawei Technologies Düsseldorf GmbHSüdwestpark 37-41, 90449 Nürnberg, Deutschland Hotline: 0080 03 38 88 888Email:******************************HUAWEI TECHNOLOGIES SWITZERLAND AGWaldeggstrasse 30 3097 Liebefeld BE SwitzerlandHotline: 0080 03 38 88 888Email:******************************HUAWEI TECHNOLOGIES CO.,LTDHuawei Industrial Base Bantian LonggangShenzhen 518129,P.R.ChinaTel.:400-822-9999 Version No.:04-(20201006)。

3MTM双面胶带

3MTM双面胶带

型号94489448H 白色胶带9448B 黑色胶带厚度0.15(mm)宽度 1.2(mm)基材不织布短期耐温性120(℃)长期耐温性80(℃)适用范围金属,铭牌,橡胶胶性:耐高温,耐候性佳,粘性强。

用途铭牌,橡胶,泡棉与橡胶粘合。

型号9080厚度0.16(mm)宽度 1.2(mm)基材:绵纸上短期耐温性200(℃)长期耐温性120(℃)适用范围金属,铭牌,橡胶丝印铭牌,标志和徽章控制面板粘接泡棉与橡胶粘合家电和电子仪器零件组装显示屏镜片产品型号9075厚度0.08(mm)宽度 1.2(mm)基材:绵纸上短期耐温性120(℃)长期耐温性80(℃)适用范围显示屏镜片标志和徽章型号9495MP胶的厚度不含离型纸mm(Mils):0.13基材:PET离型纸:58#PCK特性:在高表面能之塑料胶及金属表面有良好的剥离力耐温性:140℃抗溶:(300)℉剂性相对粘性:120℃(250)℉主要用途:图案铭板行动电话或传呼器之LCD视窗型号3M9495LE高强度双面胶带胶的厚度(不含离型纸):0.2mm,基材:PET;离形纸:58#PCK耐高温:短期140度,长期120度。

特点:双面涂布300LSE胶,针对低表面,能量表面。

主要用途:挤出成型塑胶型号3M9690白色0.13MM厚,PET基材,9690B为黑色PET,针对一般塑胶及泡棉有极佳粘度,短期耐温140摄氏度,长期耐温65摄氏度。

主要用于泡棉背胶及垫圈。

移动电话等电子产品之LCD视窗。

型号3M467MP无基材双面胶带(即胶膜)厚度0.05MM,耐高温:短期180度,长期120度。

高性能丙烯酸胶膜,可用于一般工业组装,面板冲型及其贴合3M双面胶部分3M热熔胶膜:3M615 无基材系列:3M467MP、3M468MP、3M927、3M950、3M966、3M 9460、3M9469、3M9473、3M9471、3M9472LE 、3M9472、3M9472、3M9471LE、3M9472LE、3M9671LE、3M9672LE、3M9458、3M9485、3M9703、3M9502、3M有基材系列不织布基材类:3M9448H、3M9448B、3M 9080、3M9075、3M9070、3M6408、3M9888TPET基材类:3M9495MP、3M9495LE、3M9690、3M9690B、3M9609、3M9425、3M9415、3M9500PC、3M9713、3M9731、3M9742、3M9795、3M9795B、3M9799、3M9882、3M444、3M9009、3M9888T、3M9019、3M9079、3M7945MP、3M7952MP、3M7953MP、3M7956MP、3M7959MP、3M7961MP、3M9465PC、3M9492MP、3M615、3M615S 、耐高温标签:7812、高柔性压克力泡棉类:3M4604、3M4608、3M4609、3M4615、VHB压克力泡棉类:3M4910、3M4914、3M4920、3M4926、3M4929、3M4930、3M4932、3M4941、3M4945、3M4950、3M4951、3M4952、3M4906 、3M4968、3M4955、3M4956、3M4959、PU压克力泡棉类:3M4008、3M4026、3M4032、3M4052、3M4038、3M4039、汽车用压克力泡棉类:3M4211、3M4212、3M4213、3M4215、3M4218P、3M4229P、3M4611、商标印刷类:3M7323、3M7381、3M7384、3M7600、3M7603、3M7815、3M7616、3M7818、3M7875、3M7881、3M7887、3M单面胶电工用绝缘胶带:3M1350、3M1318、3M5# 、3M10#、3M20#、3M44#、3M56#、3M1205、3M850B、3M44DA 、3M44TA、封箱用纤维胶带:3M893 、3M897、3M898、3M8915、3M8934、贴地板用标识胶带:3M471、保护膜:3M3K04电路板印刷用高温胶带:3MS10、3M69#、3M5413、3M5419、3M5490、3M7413、测试胶带:3M600# 、3M610# 、3M810、3M保护膜:3M331T、3M3112C、3M5112C、3MCPF-10、3M美纹胶带:3M244、3M2142、3M铜铝箔:3M1170、3M1181、3M1182、3M1183 3M1194 、3M1245 、3M胶水及喷胶:3M7533 WSP-1、3M75#、3M77#、3M94#、3M脚垫:3MSJ-5816、3MSJ-5808。

EM240使用说明

EM240使用说明

EM240模拟量输入模块使用说明书EM240是PLC Partner的成员之一,含4路差分16bit的模拟量输入模块。

模块外观如图1所示。

可以螺钉固定,也可以35mm导轨安装。

图 1 模块外观1、端子1.1M所有M端子内部相连,0V电平;1.2L+为电源输入,接+24V电压;1.3C+、C-为时钟脉冲输出,信号极性:脉冲电流从C+流入,C-流出;光耦隔离。

1.4D+、D-为双线传送模式时的数据脉冲输出,信号极性:脉冲电流从D+流入,D-流出;光耦隔离。

EM304模块使用说明1.5SW18位拨码开关,用于定义模块特性(驱动程序也必须相应地调整)。

SW1_1:A通道,OFF=电压输入,ON=电流输入(RA和A+短接);SW1_2:B通道,OFF=电压输入,ON=电流输入(RB和B+短接);SW1_3:C通道,OFF=电压输入,ON=电流输入(RC和C+短接);SW1_4:D通道,OFF=电压输入,ON=电流输入(RD和D+短接);SW1_5:OFF=差分输入,A+/A-、B+/B-、C+/C-、D+/D-组成四个差分输入;ON=单端输入,A+、A-、B+、B-、C+、C-、D+、D-分别和M公共端组成八个单端输入通道。

SW1_6:接线方式选择,OFF=单线方式,仅有C+/C-接至PLC;ON=双线方式,C+/C-和D+/D-均接至PLC。

SW1_7、8:脉冲速率选择,组合如下:SW1_8 SW1_7OFF OFF 正常速度OFF ON 慢速ON OFF 最慢速ON ON 高速(此选项不适合PLC,用于驳接单片机系统)1.6RA、A+、A-A+/A-组成一对差分输入,当SW1_5=ON时,则A+和A-拆分为两个相对于M端的单端输入,可以使输入通道加倍。

RA和A-之间内部接有一个高精度的250欧电阻,当用作0-20mA输入时,请把RA和A+短接,利用内部的250欧标准电阻,将电流信号转成电压后输入至A+、A-之间。

E-Chain系列产品说明书

E-Chain系列产品说明书

Features & BenefitsDirt-repellent contoured exteriorCable-friendly, smooth interior with modularinterior separationLateral glide surfaces for side mounted operationLarge pins for long service lifeDouble stop dog for long unsupported lengthTapered insertion point for easy assemblyIntergrated strain relief possibleSnap-open, hinged to left or right, accessible fromSeries 240 snap-open along the inner radius canbe combined with Series 250 snap-open alongthe outer radiusEasy to assemble and disassembleOther Installation MethodsE-Chain System ® E2 Medium Series 200/240/250Installation DimensionsLong Travels -Gliding®200240250Legend.98P D F : w w w .i g u s .c o m /e -c h a i n -p d f s S p e c s /C A D /R F Q : w w w .i g u s .c o m /e -c h a i n s R o H S i n f o : w w w .i g u s .c o m /R o H S4.178If the unsupported lengthis exceeded, the E-Chain ®/Tube must glide on itself. This requires a guide trough.Design, Chapter 1Details of material properties³ Chapter 1S = Length of travel R = Bending radius H = Nominal clearanceheightD = Overlength E-Chain ®radius in final position K = π • R + safety bu er H F = Required clearanceheightHRI = Trough inner height H 2 = *Mounting height D 2 = Overlength - longtravels, gliding K 2 = *Add-on*If the mounting bracket location is set lowerF °Technical DataSpeed / acceleration FL G max. 65.6 ft/s (20 m/s) / max. 656 ft/s 2 (200 m/s 2)Speed / acceleration FL Bmax. 9.84 ft/s (3 m/s) / max. 19.69 ft/s 2 (6 m/s 2)Gliding speed / acceleration (maximum) max. 32.81 ft/s (10 m/s) / max. 164 ft/s 2 (50 m/s 2)Material - permitted temperature igumid G / -40°F (-40°C) up to +248°F (+120° C)Flammability Class, igumid GVDE 0304 IIC UL94 HBR 2.17 (55) 2.95 (75) 3.94 (100) 4.92 (125) 5.91 (150) 6.89 (175) 7.87 (200)8.66 (225)9.84 (250)H 5.71 (145) 7.28 (185) 9.25 (235) 11.22 (285) 13.19 (335) 15.16 (385) 17.13 (435) 19.09 (485) 21.06 (535)D 4.92 (125)5.91 (150)6.69 (170)7.68 (195) 8.66 (220) 9.65 (245) 10.63 (270) 11.61 (295) 12.60 (320)K10.87 (276) 13.62 (346) 16.30 (414)19.53 (496)22.76 (578)25.98 (660)29.21 (742) 32.05 (814) 36.22 (920).341.01.6701.344.03 1.64 3.28 6.564.728.202.69FL BFL G3.28 6.5613.129.8416.41F i l l w e i g h t l b s /f tUnsupported length in ft FL B / FL GLength of travel S in ft5.386.72DHH - 1.38 (35)R +61.81(46)S/2S1.38(35)Moving EndFixed EndFL GFL BHH FS (FL G )S (FL B )Short travel, unsupported lengthO FL B = unsupported with permitted sagO FL G = unsupported with straight upper runFurther information ³ Design, Chapter 1The required clearance height: H F = H + .98 in. (25 mm) (with 1.01 lbs/ft (1.5 kg/m) fill weight.Please consult igus ® if space is particularly restricted.U n s u p p o r t e d E-Chains ® feature positive camberover short travels. This must be accounted for when specifying the clearance height. Please refer to Installation dimensions for further details.Short Travels - Unsupported+4For long travels with lowered mounting heightLong travel lengths from 32.8 ft. (10 m) to max. 328 ft. (100 m)S/2SD 2K 2S/2H R IH 2RGuide trough with glide barGuide trough without glide barTotal length of guide troughFixed endMoving end = offset fixed pointIn case of travels between 13 ft. (4m) and 32.8 ft. (10m) we recommend a longer unsupported length.R 2.17 (55) 2.95 (75) 3.94 (100) 4.92 (125) 5.91 (150) 6.89 (175) 7.87 (200) 8.66 (225) 9.84 (250)H 2 — — 3.94 (100) 3.94 (100) 3.94 (100) 3.94 (100) 3.94 (100)3.94 (100)3.94 (100)D 2+25 — — 14.96 (380) 17.32 (440) 23.23 (590)29.72 (755)37.40 (950) 40.94 (1040)44.49 (1130)K 2— — 25.35 (644) 28.98 (736) 39.84 (1012) 48.90 (1242) 57.95 (1472) 63.39 (1610) 70.63 (1794)6CL——8.03 (204)9.61 (244)14.33 (364)19.84 (504)26.54 (674)29.69 (754)31.65 (804)For center mount applications:Chain length: = s /2 +K 2+4Pitch per link: = 1.81” (46 mm)Links per ft (m): = 6.63 (22)For center mount applications:Chain length = s /2 +KRSeries 240 - Snap-open along the inner radius RR•Stackable •Stackable® E2 Medium Strain relief for steel mounting bracketsClip-on connection is not possible with steel mounting brackets. In this case, the tiewrap plates must be bolted directly into separate bore holes in front of the mounting bracket. Alternatively the tiewrap plates 20XX-ZB can be also used here. Details chapter 10Option 1:Tiewrap plates as an individual partAvailable as an individual component, can be fixed onto a mounting bracket with the use of a profile rail.Tiewrap n DimensionDimensionPlates Number C Bof Teeth 2020-ZB 3 1.18 (30) .59 (15)2030-ZB 4 1.57 (40) .79 (20)2040-ZB 5 1.97 (50) 1.18 (30)2050-ZB 6 2.36 (60) 1.57 (40)2070-ZB 8 3.15 (80) 2.36 (60)2090-ZB 9 3.54 (90) 2.76 (70)2100-ZB 10 3.94 (100) 3.15 (80)2125-ZB124.72 (120)3.94 (100)For more information please refer to strain relief section of Chapter 10Cable tiewraps as individual partsCable tiewraps Width x Length Maximum ØTensile Strength100 pieces/bag in. (mm) in. (mm) lbs (N)CFB-001.19 x 5.91 (4.8 x 150)1.42 (36)50 (222)。

纳米综合美容仪使用手册说明书

纳米综合美容仪使用手册说明书

纳米综合美容仪使用手册NV-9000NV-9000ANV-9000BNV-9000CNV-9000D 9000 系列前言首先让我们向购买本公司仪器的客户们表示衷心的感谢。

本手册是为了客服们能更好地使用这台仪器而编写的。

希望公司的产品和服务带给您尊崇礼遇。

注意本产品必须严格按照本手册中的使用方法使用,乱用误用说明书以外的方法导致的一切后果由其本人负责,公司不承担任何责任。

本公司不作任何形式的担保,包括(但不限于)为某一特定目的对其提出的实销性与适合性的默示担保。

本公司对于本资料所包含的错误,或由于本手册的提供,实际表现和使用所造成的偶发或间接损害不承担责任。

本手册包含受专利法保护的专有资料。

版权所有,未经本公司书面同意,不得对本手册的任何部分进行照相、复印、复制或翻译成其他语言。

手册中所包含的内容可以对用户不予通知而做出改变。

制造商的责任本公司仅在下列情况下才认为应对仪器的安全性、可靠性的性能负责,即:装配操作、重调、改进和维修均由本公司认可的人员进行,有关的电气设备符合国家标准,以及仪器按照操作指导进行使用。

警告:这是一种美容仪器。

如果负有使用此仪器责任的美容机构不能实现一套满意的操作方案,则会造成不正常的仪器失效,且可能危及人身健康。

现今,本公司将在用户提出要求时有偿提供电路图,另外列表说明校准方法以及其它信息,以帮助用户由适当的、合格的技术人员来维修那些本公司归类可由用户维修的仪器部分。

保证制造工艺及原材料:本公司保证仪器(除配件外)在经常使用及维修状态下,从装运之日起一年内无生产工艺及原材料故障。

本公司的任何检验并非完善无缺。

本手册中此用户手册包含了本仪器所有的一般资料。

这是新用户开始使用本仪器的出发点,因为它对系统进行了一般介绍,说明它是如何工作的,介绍了本仪器安装及各种操作方法。

可以通过目录来寻找到所需资料。

本手册是为熟悉本仪器相关的美容知识,并在使用美容操作设备方面有经验的人员阅读的。

KODAK DC240 Zoom数位相机产品说明说明书

KODAK DC240 Zoom数位相机产品说明说明书

P i c t u r e s t a k e n w i t h K O D A K D C 240 Z o o m D i g i t a l C a m e r a .In today’s demanding world of business,you couldn’t ask for a better image-building tool than the KODAK DC240 Zoom Digital Camera.It gives you the power to improve workflow.Access images quickly.Sell and communicate more effectively.It all begins with 1.3 million (1280 x 960) pixel picture resolution and a powerful 3X optical plus 2X digital zoom lens -with enough detail for exceptionally sharp,colourful,photo-realistic 13 x 18cm prints.And the DC240 comes with all the user-friendly features you demand.Making it an unquestionably smart business choice.Point and Shootexcellence forHigh Performancework.Photo-Realistic 13x 18cm Prints1.3 million (1280 x 960) pixel resolution,with enough detail for exceptionally sharp,colourful,photo-realistic 13 x 18cm prints.3X Optical Plus 2X Digital ZoomGets you closer to your subject.Lens optically extends to 3X with no loss in image quality.Plus,for added flexibility,the camera can digitally zoom on an additional 2X.And you can preview your shot on the LCD,to make sure it’s perfect.Fast and ResponsiveExceptionally responsive,with full MACINTOSH and WINDOWS USB support - for fast picture downloads.Quick power-up.Short shutter lag time so you can keep shooting.8 MB KODAK Picture Card stores 21 to 120 pictures before down-loading or inserting a new card.Easy to UseAuto focus and exposure control plus Ni-MH rechargeable batteries with charger,KODAK Picture Easy Software and a friendly interface make this camera easy to learn and use.Pictures Your WayDo more with your pictures! Enhance them with borders,or use sepia tone and black-and-white special effects.Watch pictures on TV with convenient video-out connection.DC240 Zoom Digital CameraW I T H P I C T U R E E A S Y S O F T W A R EDC240 Zoom Digital CameraW I T H P I C T U R E E A S Y S O F T W A R EA u to F o c u s 3xZ oo m•K OD A KE K T A N A R L e n sF2.8-4.539-117mm (Eq u i v)•MEGAPIXELZ D C240 O O MD i gi ta l C a me r a T AKE P ICTURES. F URT HER.P R O D U C T S P E C I F I C A T I O N SDC240 Zoom Digital CameraW I T H P I C T U R E E A S Y S O F T W A R EKodak, and Take Pictures. Further. are trademarks. Because of our constant endeavour to improve quality and design,modifications may be made to products from time to time. Details of stock availability and specifications given in this publication are subject to change without notice. All weights and dimensions are approximate.S Y S T E M R E Q U I R E M E N T SCCD Resolution 1344 x 971 pixels Image Resolution 1280 x 960 pixels (high),640 x 480 pixels (standard)Image Quality Good, Better, BestSettings Image Storage8 MB KODAK Picture Card included. Stores 21 to 120 picturesViewfinder45mm TFT colour LCD for review and preview, plusoptical viewfinder LensAuto focus 3X zoom Digital2X digital zoomEnhancementLens Focal Length 39 mm to 117 mmequivalent Focus Range 0.5 m to infinity Macro 0.25 mExposureAuto, or manual override (+/- 2 EV in 0.5-EV incre-ments), automatic white balance and exposure lock Shutter Speed 1/2 to 1/755 second Aperture RangeWide: f /2.8 to f /16;Tele: f /4.5 to f /25.7P A C K A G E C O N T E N T S• KODAK DC240 Zoom Digital Camera withhand strap and lens cover •8 MB KODAK Picture Card •4 AA batteries• 4 AA Ni-MH rechargeable batteries and charger •Serial connection for WINDOWS and MACINTOSH Systems•USB cable for WINDOWS and MACINTOSH Systems •Video cable•Quick setup card, user’s guide, registration cards CD-ROMs containing software, including:• KODAK Picture Easy Software (WINDOWS)•TWAIN Acquire Module (WINDOWS)•PHOTODELUXE Software and PAGEMILL Software from Adobe Systems, Inc MACINTOSH and WINDOWS•Camera Mounter Software for WINDOWS 95,98 and NT 4.0• PHOTOSHOP-compatible plug-in and Picture Transfer Application (MACINTOSH)ISO Equivalent 140Self-Timer10 secondsTripod Mount StandardFlashStrobe flash (auto, red-eye, fill, off) range up to 3.0 mFile Format JPEG (EXIF)User InterfaceGraphical, menu-driven, easy to navigate Video OutNTSC, PAL (user selectable)Time & Date Stamp Optional Special Effects Full-colour borders; sepiaand B&W modes Interface USB, serial, PC card Power 4 AA batteries (included)or AC adapter (optional)Dimensions 133 mm (w) x 51 mm (d) x 76 mm (h)CertificationsVCCI, CE, FCC Class B, C-Tick, ICES-003 Class B, CCIBWeight 328 g without batteries WarrantyOne year (or as local jurisdiction requires)WINDOWS Systems:•WINDOWS 95, 98 or NT 4.0 Software (to use USB, must have WINDOWS 98)•PC with PENTIUM 90 MHz or greater processor •16 MB or more of RAM •70 MB hard disk space available •CD-ROM drive for software installation •256-colour monitor (16-bit colour recommended)•Available serial port, USB port, or PC card reader KODAK Picture Easy Software:•PC with PENTIUM 90 MHz or greater processor •WINDOWS 98 with 24 MB of RAM, or WINDOWS 95 with 16 MB of RAM, or WINDOWS NT 4.0 with 32 MB of RAM • A minimum of 70 MB of free disk space before Picture Easy Software installation • CD-ROM drive for software installation • 256-colour monitor (16-bit colour recommended)• 800 x 600 screen resolution recommended MACINTOSH Systems:• MAC OS 7.6.1/8.X/9.0/9.0.4/9.1 for serial • MAC OS 8.6/9.0/9.0.4/9.1 for USB •16 MB or more of RAM •70 MB hard disk space available •CD-ROM drive for software installation •256-colour monitor (16-bit colour recommended)•Available serial port, USB port, or PC card readerS P E C I F I C A T I O N SO R D E R I N G I N F O R M A T I O N /A C C E S S O R I E SProduct Name CAT No.DC240 Premium Pack (European English)168 2590(French/German) 885 7351(Italian/Spanish)872 8354Picture Card Adapter156 159648 MB Picture Card142 062948 MB Picture Card with Adapter 187 791932 MB Picture Card180 690032 MB Picture Card with Adapter 196 484020 MB Picture Card146 862820 MB Picture Card with Adapter 824 202610 MB Picture Card863 382810 MB Picture Card with Adapter 849 2399AC Adapter190 9282KODAK Accessories help make this great camera even better.Visit us at /go/accessories.For more information on our range of Kodak Digital products call free on:Austria/Österreich 0 660 7348 Belgium/Belgique 0800 72247Denmark/Danmark 80 01 09 24 Eire1800 409391Finland/Suomi 0800 1 17056 France0800 90 62 81Germany/Deutschland 0130 82 54 02Greece/Hellas 00800 44125605 Italy/Italia1678 72996Netherlands/Nederland 0800 0224428Norway/Norge 800 1 1848Spain/España 900 98 4485Sweden/Sverige020 793169Switzerland/Schweiz/Suisse 0800 551034UK0800 281487UK Toll Line +44 (0) 131 458 6714UK Fax No+44 (0) 131 458 6962Alternatively contact your local Reseller or Kodak office.。

MNPV系列PV组合器说明书

MNPV系列PV组合器说明书

MNPV Installation InstructionsIMPORTANT SAFETY INSTRUCTIONSSave these instructions – This manual contains important instructions for Models MNPV12, MNPV12-250, MNPV16, MNPV16-250Configurations:The MNPV12 and MNPV16 combiners are listed for outdoor use. These PV combiners are designed for combing PV strings up to 150 & 300 VDC using MNEPVXX circuit breakers, and up to 600VDC using MNTS touch safe fuse holders.The MNPV12 comes with a 200 amp plus busbar thatworks with up to ten fuse holders or twelve 150VDCcircuit breakers. Two busbars can be joined together, orseparated to create two systems up to 5 strings of fuseholders or 6 strings of breakers each. The pictures tothe right show breakers on the top row and fuse holderson the bottom row.The MNPV12-250 comes with 168 ampbusbars that work with up to six of theMidNite 300VDC breakers. The MNPV12-250 busbars may be joined toaccommodate 6 strings or separated for twoindependent sets of three strings.MNPV Installation Instructions (continued)The MNPV16 comes with a 240 amp plus busbar toaccommodate up to 16 touch safe fuse holders.The MNPV16-250 comes with a 240 amp plus busbar thataccommodates up to twelve 300VDC circuit breakers.Note: The amperage rating of the plus busbars is noted above to help insure that the maximum current rating is not exceeded in any field configuration.The MNPV series of combiners may be used as a DC load center as well as a PV combiner.Note: Touch safe fuse holders should never be opened under load! This is not one of those warnings to gloss over! If opened under load, you WILL have a fire and it will not stop until the wires burn in half. There is a good reason we make the enclosures out of metal.Features:All aluminum powder coated housing. Won’t rust or degrade due to sun exposure.Flip up cover that can stay in the open position during installationPV Negative bus bar with openings for #14-6 and #1/0-14)Chassis ground bus bar with #14-6 and #1/0-14 wire openingsStandard din rail for mounting breakers or fuse holdersTin plated copper bus bars to combine breaker and fuse holder outputsDead front cover snaps into place after wiring is complete for safetyKnock outs for PV in and PV out on bottom and sidesPV IN knockouts are ½” & 7/8” concentric to allow for bulkhead mount MC connectors or strain reliefsTop surface is available to bring conduit in from directly above the enclosureNote: The plastic dead front fits very tight. You must first remove the lid in order to remove the dead front.The installation of a PV combiner is fairly straight forward. Select the location to install your combiner first. Some systems have the PV modules located close to the inverters and or battery system. If this is the case, youMNPV Installation Instructions(continued)can elect to mount the MNPV inside and run each PV string down to the MNPV inside the building. This is convenient for trouble shooting and upgrading. For longer runs the combiner will be mounted outdoors on a pole for pole mounted PV arrays or similar mounting for rack mounted arrays. The combiner can be mounted in the vertical position or slanted backwards to accommodate up to a 3/12 roof pitch. All unused holes should be blocked using RTV sealant or some similar goop in order to keep rain and bugs out of the enclosure. It is very common for critters to enter through an unused mounting hole and take up roost. They will eventually degrade the performance of your system to say nothing of the yuk factor upon discovery of their nest.The following dimensioned drawings show the enclosure size andlocation of knockouts available on the MNPV12&16. Lightningarrestors may require a locknut on the outside in order to clear the lid.Two 7/8” knockouts (1/2” conduit openings) are located on the sides of the MNPV12. These are primarily intended for lightning arrestors. One 1 ¼” conduit knockout is located on the backmounting surface.MNPV Installation Instructions(continued)PV input knockouts for these combinersare a dual concentric knockout that canaccept bulkhead mount MC cableconnectors. Configuring these enclosureswith the bulkhead mount connectors inadvance can save time in the field. Severalbrands will fit the ½” diameter knockouts.MNPV Installation Instructions (continued)Internal wiring MNPV12-250 busbars joined Wiring diagram for MNPV12-250 (joined & separated) The MNPV12 has 2/0 box lugs for the plus busbars and 1/0 openings on the PV minus and ground. Note: the MNPV12-250 has special busbars that are made exclusively for the MidNite 300 volt breakers. These breakers take up the space of two regular 13mm wide breakers. The 300 volt breakers are used for high voltage off-grid PV arrays that will employ the MidNite Classic 250 MPPT controller. The 250 volt busbar is rated for up to 168 amps continuous.MNPV12 with MNTS fuse holders MNPV12 wiring diagram with MNTS fuse holders The regular MNPV12 comes with a 1/8” thick reversible copper busbar. This busbar may be used with fuse holders above or with 150VDC breakers shown below. The busbars are rated for up to 200 amps.MNPV Installation Instructions (continued)MNPV12 with breakers combined MNPV12 breaker wiring diagram-combined busbars Some PV Panels now require a 20 amp series fuse (breaker). The MNPV12 can support ten high voltage 20 amp fuses or breakers. This combiner can accommodate all twelve positions when using 15 amp or less breakers.When selecting breakers for use with the MidNite combiners, first check with the PV manufacturer to determine the proper “series fuse”. The term fuse is used even though you are probably using breakers. This is a carry over from UL terminology.MidNite Solar offers PV combiner breakers rated up to 150VDC and 300VDC. The 150V version come in these current ratings. 1,2,3,4,5,6,7,8,9,10,12, 15, 20, 30,40, 50 and 63. The 300V version is available in 10,15, 20,30 and 50 amps. Other sizes are available on special order.Part numbers for breakers are as follows:MNEPV10, MNEPV15, MNEPV20 etc for 150 volt breakers. Part numbers for 300 volt breakers are MNEPV10-250, MNEPV15-250 etc.The MidNite MNPV12 can utilize touch safe fuse holders and fuses rated for up to 600 volts DC for high voltage strings. The MNPV12 comes with a special busbar that has reversible legs to accommodate ten of these USM1 type fuse holders made by Ferraz Shawmut. Fuses are available from 1 to 30 amps.MNPV Installation Instructions(continued)To remove the dead front:Pry off the lid as shown using something like a screwdriver asa lever.The dead front will then come out easily.Use the hardware supplied to connect the terminal box lug to the busbars. 1 10-32 x 3/8” screw, one star washer and one box lug. Connect the top side of one busbar to the other using one 10-32 x 3/8” screw and one kepnut.Photos of the first MNPV12 installation in Minnesota. Photos complements of Daryl Thayer。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

DMX512-DISCO240控制台



Ver 2.0/4.0
目录
一、参数指标-----------------------------------------------------------------------------1
二、安全使用注意事项-----------------------------------------------------------------1
三、装箱清单-----------------------------------------------------------------------------1
四、通讯电缆-----------------------------------------------------------------------------2
五、DMX 512地址分配----------------------------------------------------------------2
六、通讯电缆连线及电脑灯地址码拔码示意图-----------------------------------3
七、面板及功能区域指示图-----------------------------------------------------------4
八、面板功能区域说明-----------------------------------------------------------------4
九、双功能键的说明--------------------------------------------------------------------5
十、LCD液晶屏显示信息说明-------------------------------------------------------6 十一、电脑灯程序(场)的编辑--------------------------------------------------------7 十二、电脑灯程序的运行-----------------------------------------------------------------7 十三、特殊场景表现-----------------------------------------------------------------------8 十四、如何设置、取消摇滚杆电位器--------------------------------------------------8 十五、常规调光控制-----------------------------------------------------------------------8
非常感谢使用HENGDA系列电脑灯控制器!HD-DMX512-Disco 240控制台为国际标准DMX512信号输出。

在操作使用前,请仔细参阅说明书。

一、参数指标
二、安全使用注意事项
●控制台必须接安全大地线。

●应避免带电拔插通讯电缆。

●开机顺序:请先打开所有受控制的电脑灯电源,然后再打开控制器电源,否
则易损坏控制器。

●注意防潮湿、防水、防尘、防静电、定期维护清洁。

三、装箱清单
●HD-DMX512-Disco 240 控制台1台
●DMX 512 电缆1条
●HD-DMX512-Disco 240使用手册1本
●电源变压器1个
四、通讯电缆
●采用特征阻抗为120欧双绞屏蔽线,如电缆超过200米或灯数量较多,应加
信号提升放大器并在最后一台灯加接终端电阻(120欧姆/1W)。

●通讯电缆1脚为地(GND),2脚为信号正,不可接反接错。

●通讯电缆应单端接地屏蔽。

●通讯电缆应避免同强电一齐布线。

五、DMX 512地址分配
HD-DMX512-Disco 240控制台使用DMX 512的1-240通道,可控制16通道以内的电脑灯,地址分配
如下:
六、通讯电缆连线及电脑灯地址码拔码示意图
八、面板功能区域说明
九、双功能键区说明
十、LCD液晶屏显示信息说明
十一、
电脑灯程序(场)的编辑
1. 按[BLACK]键,使该LED 熄灭:
2. 扫[EDIT/RUN]键,使该LED 亮,进入编程状态:
3. 按数字(P1—P12)中任意键一次,选择要编程的程序(场)编号,显示在LCD 的Chase[ ]
中。

4. 再按数字(P1—P12)键,选择出受控的电脑灯,使用权之对应的LED 灯亮,若对应指示
灯不亮,则表示该灯未选中,不受第5步的影响。

5. 推动(CH1—CH8)调节电脑灯各对应通道数据,或按SA/SB 键,推动CH9—CHD16调
光对应的电脑灯效果(如果已经设置了X 、Y 运动方向扫描通道转移,则其中有两个直滑电位器推杆不起作用,您可操纵右下角摇摆电器获取数据。

) 6. 重复4、5步,调节其他电脑灯,使之所需电脑灯场景达到预定效果。

7. 推动[SPEED]、[CROSS]电位器,调节好场景停留时间及场景过渡时间。

8. 按[ + ,记忆此步场景效果,并进入下一步编辑。

(若按[ - ] 键,可查看上一步的场景,重复4、5、6、7步修改,再按[ + 贮存。

) 9. 重复4-8步,编辑其他场景(程序步)。

10.按[EDIT/RUN]键,使该对应指示灯熄灭,记忆并退出编辑状态,进入运行状态。

11.重复2-10步,编辑其他程序场。

十二、 电脑灯程序的运行
1. 按[EDIT/RUN]键,使该对应LED 灯熄灭。

2. 按数字键(P1-P12),选择程序(场)编号,使之运行,若该程序(场)未被编辑,则按此
键号时对应的LED 灯不亮。

3.调节[SPEED]及[CROSS]电位器,改变场景与场景之间的停留时间及场景渐变运行速度,若[SPEED]或[CROSS]电位器处于下部份AUTO区域,则自动运行已编辑好
的场景停留及场景过渡时间。

4.按[CROSS MODE]键,可转换运行模式,详见:九、双功能键区说明
5.若想执行手动或自动混合运行程序,则可按下述步骤设定运行。

a)首先释放通道:按[CHANNELS]键,再按(P1—P8)键(或按[SHIFT],再按PCH9—PCH16),
释放对应通道,把F变成O,最后再按[CHANNELS]键,记忆退出。

(F:代表该对应通道,
在程序运行中不、接收手动数据,受已编程序控制。

O:代表该对应通道在程序运行中,
已不再受程序控制,接受手动推子数据。


b)选好要运行释放通道的灯:按[MANUAL]键,再按(P1—P12)键,选出要执行手动控制
的灯号,随机推动相应已释放好的电位器推子,执行手动+自动混合运行程序,按[MANUAL]
退出手动选择。

6.按[BLACK]可使运行程序(场)做暂停/启动选择,对应键LED灯灭时则输出运行正常。

十三、特殊场景表现
在运行程序状态下(即[RUN/EDIT]键对应指示灯熄灭),按[RUN SCENE]键,再按P1—P12中任意键,可调出已编程的第1号程序场中的前12个场景,所以我们建议第1号程序场的前12个场景在编程时,最好有特殊定义,可作一些特技表演效果。

十四、如何设置、取消摇滚杆电位器
设置摇滚杆电位器设置:按[RUN/EDIT]键,使该指示灯点亮,紧接着按[SET X/Y]键,根据液晶屏的提示,从(P1-P8)或按SA/SB键,从(PCH9—PCH16)中选取出两个对应电脑灯X、Y运行方向的扫描通道,转移到胀摇滚杆电位器去控制绿色指示灯,随即点亮,如果输入错误,按[DELETE]键取消输入,重新键入正确的对应通道,再按[SET X/Y]键记忆退出。

取消摇滚杆电位器设置:在[SET X/Y]状态下,按[DELETE]清除输入数据,绿色指示灯随即熄灭,再按[SET X/Y]键记忆退出。

十五、常规调光控制
点控:按动P13-P24控制调光的206-217通道,指示灯亮时表示输出100%,指示灯灭时输出0%。

分控:在非编程状态下,按SCAN/LIGHT键使指示灯亮,进入调光状态,按SA/SB/SC选择调光控制的通道页面,推动推子区的各个推子调节调光输出。

相关文档
最新文档