Zytel PA612 153HSL NC010 物性表
美国杜邦 PA66 HTN501NC010 物性表
HTN501 NC010 is a 30% glass reinforced, flame retardant, lubricated high performance polyamide HTN501 NC010DuPont ™ Zytel ®HTNhigh performance polyamide resinZytel ®ValueDAM50%RHIdentification Part Marking Code ISO 11469>PA6T/XT-GF35FR< Part Marking Code SAE J1344>PPA-GF35FR<Mechanical Stress at Break ISO 527MPa (kpsi)165 (24) Strain at Break ISO 527% 1.6 Tensile Modulus ISO 527MPa (kpsi)13000 (1885) Shear Strength ASTM D 732MPa (kpsi)64 (9.3)70 (10) Flexural Modulus ISO 178MPa (kpsi)12000 (1740)12000 (1740) Flexural Strength ISO 178MPa (kpsi)250 (36)235 (34)Compressive Strength ASTM D 695MPa (kpsi)293 (42.6) Compressive ModulusASTM D 695MPa (kpsi)3580 (520)Notched Charpy Impact Strength ISO 179/1eAkJ/m2-30°C (-22°F)13 23°C (73°F)11 Unnotched Charpy Impact Strength ISO 179/1eUkJ/m2-30°C (-22°F)30 23°C (73°F)40Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2008080505/080804The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in thispublication is to be considered as a license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. CAUTION: Do not use DuPont materials in medical application involving implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont undera written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use. For further information, please contact your DuPont representative. You may also request a copy of DuPont POLICY Regarding Medical Applications H-50103-3 and DuPont CAUTION Regarding Medical Applications … H-50102-3Zytel ®resin. It is also a PPA resin.PropertyTest Method UnitsDuring molding, use proper protective equipment and adequate ventilation. Avoid exposure to fumes and limit the hold up time and temperature of the resin in the machine. Purge degraded resin carefully with HDPE.Zytel®ValueDAM50%RHThermalDeflection Temperature ISO 75-1/-2 °C (°F)0.45MPa 270 (518) 1.80MPa260 (500)Melting Temperature ISO 11357-1/-3 °C (°F)10°C/min, First Heat 300 (574)CLTE, Parallel ISO 11359-1/-2E-4/C (E-4/F)-40 - 23°C (-40 - 73°F)0.20 (0.11) 23 - 55°C (73 - 130°F)0.18 (0.10) 55 - 125°C (131 - 257°F)0.18 (0.10)CLTE, Normal ISO 11359-1/-2E-4/C (E-4/F)-40 - 23°C (-40 - 73°F)0.46 (0.26) 23 - 55°C (73 - 130°F)0.50 (0.28) 55 - 125°C (131 - 257°F)0.60 (0.33)Glass Transition Temperature DMA °C (°F)140 (284)90 (194)Electrical Surface Resistivity IEC 60093ohm 1E13 Volume Resistivity IEC 60093ohm m >1E131E13 Electric Strength IEC 60243-1kV/mm (V/mil)1.0mm34 (863)34 (863)Relative Permittivity IEC 602501E2 Hz 3.9 1E3 Hz 3.8 1E6 Hz 3.6Dissipation Factor IEC 60250E-41E2 Hz 80 1E3 Hz 130 1E6 Hz 150Arc Resistance ASTM D 495s 80 CTIIEC 60112V 525Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2008080505/080804The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in thispublication is to be considered as a license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. CAUTION: Do not use DuPont materials in medical application involving implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont undera written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use. For further information, please contact your DuPont representative. You may also request a copy of DuPont POLICY Regarding Medical Applications H-50103-3 and DuPont CAUTION Regarding Medical Applications … H-50102-3PropertyTest Method UnitsHTN501 NC010Zytel®ValueDAM50%RHFlammabilityFlammability Classification UL940.81mm V-0Oxygen Index ISO 4589-1/-2%37Hot Wire Ignition UL 746As0.81mm >150 1.5mm >150 3.0mm>150Temperature Index RTI, Electrical UL 746B°C0.81mm 150 1.5mm 150 3.0mm 150RTI, Impact UL 746B°C0.81mm 120 1.5mm 125 3.0mm 130RTI, Strength UL 746B°C0.81mm 130 1.5mm 130 3.0mm150Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2008080505/080804The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in thispublication is to be considered as a license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. CAUTION: Do not use DuPont materials in medical application involving implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont undera written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use. For further information, please contact your DuPont representative. You may also request a copy of DuPont POLICY Regarding Medical Applications H-50103-3 and DuPont CAUTION Regarding Medical Applications … H-50102-3PropertyTest Method UnitsHTN501 NC010Zytel®ValueDAM 50%RHOther DensityISO 1183kg/m 3 (g/cm 3)1680 (1.68)Hardness, Rockwell ASTM D 785Scale M 108 Scale R 124Taber AbrasionASTM D 1044mgCS-17 Wheel, 1kg, 1000 cycles 57Water Absorption ASTM D 570%Immersion 24h 0.25Molding Shrinkage ISO 294-4%Normal, 2.0mm 0.5 Parallel, 2.0mm 0.2ProcessingMelt Temperature Range °C (°F)320-330 (610-625) Mold Temperature Range °C (°F)140-160 (280-320)Drying Time, Dehumidified Dryer h 6-8 Drying Temperature°C (°F)100 (210) Processing Moisture Content%<0.10Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2008080505/080804The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in thispublication is to be considered as a license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. CAUTION: Do not use DuPont materials in medical application involving implantation in the human body or contact with internal body fluids or tissues unless the material has been provided from DuPont undera written contract that is consistent with DuPont policy regarding medical applications and expressly acknowledges the contemplated use. For further information, please contact your DuPont representative. You may also request a copy of DuPont POLICY Regarding Medical Applications H-50103-3 and DuPont CAUTION Regarding Medical Applications … H-50102-3PropertyTest Method Units HTN501 NC010。
物性表
DuPont ™ Zytel®nylon resinZytel ®101L NC010ValueDAM50%RHIdentification Resin Identification ISO 1043PA66 Part Marking Code ISO 11469>PA66<Mechanical Yield Stress ISO 527MPa (kpsi)82 (11.9)55 (8.0)Strain at Break ISO 527%50mm/min45Nominal Strain at Break ISO 527%25>100 Yield Strain ISO 527% 4.525 Tensile Modulus ISO 527MPa (kpsi)3100 (450)1400 (200) Tensile Creep Modulus ISO 899MPa (kpsi)1h 1400 (200) 1000h 820 (119)Poisson's Ratio 0.41Flexural ModulusISO 178MPa (kpsi)2800 (410)1200 (174)Notched Charpy Impact Strength ISO 179/1eAkJ/m2-30°C (-22°F) 4.53 23°C (73°F)5.515 Unnotched Charpy Impact Strength ISO 179/1eUkJ/m2-30°C (-22°F)400NB 23°C (73°F)NBNBContact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2005.050630/050630The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", H-50102.Zytel ® 101L NC010 is a lubricated polyamide 66 resin for injection molding.PropertyTest Method UnitsZytel ®101L NC010ValueDAM50%RHThermalDeflection Temperature ISO 75f °C (°F)0.45MPa 200 (392) 1.80MPa70 (158)Melting Temperature ISO 11357-1/-3 °C (°F)10°C/min 262 (504)CLTE, Normal ISO 11359-1/-2E-4/C (E-4/F)23 - 55°C (73 - 130°F) 1.1 (0.61)CLTE, Parallel ISO 11359-1/-2E-4/C (E-4/F)23 - 55°C (73 - 130°F) 1.0 (0.55)Vicat Softening Temperature ISO 306°C (°F)50N 238 (460)Electrical Surface Resistivity IEC 60093ohm 1E12 Relative Permittivity IEC 602501E2 Hz 3.810.9 1E6 Hz3.54 Volume Resistivity IEC 60093ohm m 1E121E10 Dissipation Factor IEC 60250E-41E2 Hz 802100 1E6 Hz 180750Electric Strength IEC 60243-1kV/mm (V/mil)1.0mm 31.5 (800)CTI IEC 60112V 600CTI UL 746AV3.0mm>600Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2050630/050630The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", H-50102.PropertyTest Method UnitsZytel ®101L NC010ValueDAM50%RHFlammabilityFlammability Classification IEC 60695-11-100.71mmV-2Flammability Classification UL940.71mm V-2Oxygen IndexISO 4589-1/-2%28Glow Wire Flammability Index IEC 60695-2-12°C0.71mm 960 1.5mm 960 3.0mm960Glow Wire Ignition Temperature IEC 60695-2-13°C0.71mm 725 1.5mm 750 3.0mm800High Amperage Arc Ignition Resistance UL 746Aarcs0.71mm 120 1.5mm 168 3.0mm 182 6.0mm200High Voltage Arc Tracking Rate UL 746A mm/min (in/min)5.10 (0.2)Hot Wire Ignition UL 746As0.71mm 7 1.5mm 13 3.0mm 17 6.0mm20Temperature Index RTI, Electrical UL 746B °C0.71mm 130RTI, Impact UL 746B °C0.71mm 75RTI, Strength UL 746B°C0.71mm85Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2050630/050630The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", H-50102.PropertyTest Method UnitsZytel ®101L NC010ValueDAM 50%RHOther DensityISO 1183kg/m 3 (g/cm 3)1140 (1.14)Ball Indention Hardness ISO 2039-1MPa (kpsi)H 358/3085 (12)H 961/30160 (23)Hardness, Rockwell ISO 2039/2Scale M 7959 Scale R 121108Water Absorption ISO 62, Similar to%Equilibrium 50%RH 2.6 Saturation, immersed 8.5Molding Shrinkage ISO 294-4%Normal, 2.0mm 1.4 Parallel, 2.0mm 1.4Mold Shrinkage %Flow, 3.2mm (0.126in) 1.5ProcessingMelt Temperature Range °C (°F)280-300 (535-570)Melt Temperature Optimum °C (°F)290 (555) Mold Temperature Range °C (°F)50-90 (120-190)Mold Temperature Optimum °C (°F)70 (160) Drying Time, Dehumidified Dryer h 2-4 Drying Temperature°C (°F)80 (175) Processing Moisture Content%<0.20Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm. Test temperatures are 23°C unless otherwise stated.The DuPont Oval Logo, DuPont™, The miracles of science™ and Zytel® are trademarks or registered trademarks of DuPont Company. Copyright© 2050630/050630The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as alicense to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body. For other medical applications see "DuPont Medical Caution Statement", H-50102.PropertyTest Method Units。
PA 加玻纤
其它
乙酸乙酯 (23°C) 过氧化氢 (23°C) DOT4号刹车油 (130°C) 乙二醇水溶液 (50g/100g) (108°C) 1g/100g 基苯氧- 聚环氧乙烷乙烯水溶液 (23°C) 油酸 (50g/100g) + 橄榄油 (50g/100g) (23°C) 水 (23°C) 去离子水 (90°C) 酚溶液(5g/100g) (23°C)
函数 应力-应变.
应力-应变. Zytel® 70G13HS1L NC010 (干)
140
B
120
B
100
80
60
40
-40 °C 23 °C 80 °C 100 °C 120 °C
B折断
B BB
20
0 01234567 应变 在 %
正割模量-应变.
正割模量-应变. Zytel® 70G13HS1L NC010 (干)
测试标准 ISO 11357-1/-3 ISO 11357-1/-2 ISO 75-1/-2 ISO 75-1/-2 ISO 11359-1/-2 ISO 11359-1/-2 IEC 60695-11-10 IEC 60695-11-10 IEC 60695-11-10 IEC 60695-11-10 -
All data provided according to ISO 10350 for single points and ISO 11403 for multipoints.
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc. Test temperatures are 23°C unless otherwise stated.
通用尼龙物性表
尼龙(PA)材料的特性一尼龙简介尼龙(Nylon,Polyamide,简称PA)是指由聚酰胺类树脂构成的塑料。
此类树脂可由二元胺与二元酸通过缩聚制得,也可由氨基酸脱水后形成的内酰胺通过开环聚合制得,与PS、PE、PP等不同,PA不随受热温度的升高而逐渐软化,而是在一个靠近熔点的窄的温度范围内软化,熔点很明显,熔点:215-225℃。
温度一旦达到就出现流动。
PA的品种很多,主要有PA6、PA66、PA610、PA11、PA12、PA1010、PA612、PA46、PA6T、PA9T、MXD-6芳香醯胺等.以PA6、PA66、PA610、PA11、PA12最为常用.尼龙类工程塑料外观上都呈现为角质、韧性、表层光亮、白色(或乳白色)或微黄色、透明或半透明的结晶性树脂,它容易被著成任一种颜色。
作为工程塑料的尼龙分子量一般为1.5-3万。
它们的密度均稍大于1,密度:1.14-1.15g /cm3。
拉伸强度:> 60.0Mpa。
伸长率:> 30%。
弯曲强度: 90.0Mpa 。
缺口冲击强度:(KJ/m2) > 5。
尼龙的收缩率为1%~2%. 需注意成型后吸湿的尺寸变化。
吸水率 100% 相对吸湿饱和时能吸8%.使用温度可-40~105℃之间。
熔点:215-225℃。
合適壁厚2-3.5mm. PA的机械性能中如抗拉抗压强度随温度和吸湿量而改变,所以水相对是PA的增塑剂,加入玻纤后,其抗拉抗压强度可提高2倍左右,耐温能力也相应提高,PA本身的耐磨能力非常高,所以可在无润滑下不停操作,如想得到特別的润滑效果,可在PA中加入硫化物。
二 PA性能的主要优点有:1. 机械强度高,韧性好,有较高的抗拉、抗压强度。
比拉伸强度高于金属,比压缩强度与金属不相上下,但它的刚性不及金属。
抗拉强度接近于屈服强度,比ABS 高一倍多。
对冲击、应力振动的吸收能力强,冲击强度比一般塑料高了许多,并优于缩醛树脂。
2. 耐疲劳性能突出,制件经多次反复屈折仍能保持原有机械强度。
FR50NC010
修订: 2016-06-21 To find out more, visit DuPont Performance Polymers or contact nearest DuPont location.
North America Tel: +1 302 999-4592 Toll-Free (USA): 800 441-0575
测试标准 测试标准 ISO 527-1/-2 ISO 527-1/-2 ISO 527-1/-2 ISO 179/1eA 测试标准 ISO 75-1/-2 UL 746B
UL 746B
UL 746B
测试标准 IEC 60695-11-10 IEC 60695-11-10 UL 94 IEC 60695-11-10 IEC 60695-11-10 UL 94 IEC 60695-11-20 IEC 60695-11-20 UL 94 ISO 3795 (FMVSS 302) ISO 3795 (FMVSS 302) 测试标准 IEC 60112 测试标准 ISO 1183 类似ISO 62 测试标准 -
Page: 2 of 2
单位 -
单位 % % 单位 MPa MPa % kJ/m² 单位 °C
130 / *
°C
130 / *
°C
130
°C
105
°C
115 / *
°C
115
°C
105 115 / *
120 干态/调节后 V-0 / * 1.5 / * yes / * V-0 / * 0.75 / * yes / * 5VA / * 1.5 / * yes / * V-0 / *
PRODUCT INFORMATIቤተ መጻሕፍቲ ባይዱN
Zytel 70G30HSL NC039B 物性表
1/3
• 北美洲 • 非洲和中东 • 拉丁美洲
• 南美洲 • 欧洲 • 亚太地区
• 玻璃纤维增强材料, 30% 填料按重量
• 抗水解
• 热稳定剂
• 超声波可焊接 • 刚性,高 • 高强度 • 抗冻 • 良好的抗热老化性
• 良好的抗蠕变性 • 良好的耐热老化性能 • 耐化学性良好 • 耐疲劳性能 • 耐水解性
总体
材料状态
• 已商用:当前有效
资料 1
• Processing - Injection Molding (English) • Processing - Injection Molding of Glass-reinforced Zytel (English) • Technical Datasheet • Typical Processing for DuPont Engineering Polymers (English)
--调节后的 7200 130 5.0
--干燥
6800 5100 调节后的
10
10
13
15
• 中美洲
• 耐油 • 耐油性能 • 耐油脂性能 • 热稳定性 • 热稳定性
单位制 g/cm³
% %
% % 单位制 MPa MPa %
MPa MPa 单位制
kJ/m² kJ/m²
测试方法 ISO 1183 ISO 294-4
10.8 4.60
0.46 0.065
--调节后的
--
单位制
kJ/m² kJ/m²
kJ/m² kJ/m² 单位制
测试方法 ISO 179/1eU
ISO 180/1A
创新性汽车燃油及流体管路系统应用介绍
可制造性 • 可以挤出或者吹塑成型 • 易热成型和制造波纹管 • 易与和其它部件联接
PA612单层溢流管解决方案
PA612: Zytel LC6200 BK385 在100oC-125oC范围内具有良好的耐水解性能 耐道路盐及各种车用介质 成本较PA12相当 国际主机厂普遍采用(GM,PSA...) 化学改性PA612 Zytel LC7602BK010A 具有更好的柔韧性 最新开发的PA612 Zytel LC7603BK195可以满足130oC长期耐水解要求
Fuel Lines燃油管路 Zytel®
Fuel Rail Zytel®
Carbon 碳罐
Zytel®
Filler Neck
加油口总成
Filler Pipe 加油管 Selar®RB, Bynel®,
Delrin®, Zytel®
汽车燃油管路系统
多层燃油管 PA6/E油管路系统新进展(II)
2016年8月 VW公布新的多层燃油管新标准VW TL52712,新标准首次对燃油管可溶析出物作出明
确要求,未来将高析出材料PA6及PA12排除作为燃油管内层材料使用
测试方法 燃油类型
SAE J2260
CE10 (45% Toluene; 45% Isooctane; 10% ethanol
PA 11 PA 12
HMD + DDDA
218
10 diamine + Sebacic acid
205
11 amino acid
189
Laurolactam
178
Flex or Young’s Modulus
(Mpa) 2800
2900
2250