SLS使用说明书

合集下载

SLSC-30使用说明书

SLSC-30使用说明书

SLSC-30使用说明书
1、SLSC-30安装好后先将导热油脂注入油槽之三分之二处,再接通电源。

2、将电源开关拨至ON档,同时打开泵电源,仪表显示红色数码400,下排为0.00,静止30秒后,上排显示值为现时的油温,按□/SET键,蓝色键,上排显示SP,按▲或▼键,使下排显示为所需要的设定温度,再按蓝色键返回,此时上排红色指示为SLSC-30油槽内实际温度,下排黄色为设定温度。

3、如初次使用温差较大时,可在设定温度返回后,按▲或▼键等SET指示灯闪烁时,松开键即可。

4、使用完SLSC-30后,请将电源开关拨至OFF档,同时将电源插头取下。

5、该产品使用220伏交流电,电源采用三脚安全插头,其中一只zui长的脚,为安全接地脚,为此对应使用三眼插座应妥善接地。

3D Systems SLS材料指南说明书

3D Systems SLS材料指南说明书

DuraForm® EX & ProX® EX BlackDuraForm® EX NaturalDuraForm® ProX® AF+DuraForm® TPUDuraForm® FLEXDuraForm® HST & ProX® HSTCastForm™PSDuraForm® PA & ProX® PADuraForm® FR1200 & ProX® FR1200DuraForm® GF & ProX® GFSLSProduction GradeMaterialsNEW!NEW!NEW!Flexible / durableFlame retardantStiff / rigidHigh temperature resistanceStiff / rigidHigh temperature resistanceStiff / rigidHigh temperature resistanceSLS Materials GuideUltimate Production.NEW!DuraForm® EX & ProX® EX BlackDuraForm® EX NaturalDuraForm® PA & ProX® PADuraForm® FR1200 & ProX® FR1200DuraForm® ProX® AF+DuraForm® GF & ProX® GFDuraForm® HST & ProX® HSTDuraForm® TPUDuraForm® FLEXCastForm™ PSNYLON 11NYLON 11NYLON 12NYLON 12NYLON 12NYLON 12NYLON 12THERMOPLASTICTHERMOPLASTICPOLYSTYRENEFREE EBOOK!DuraForm ® EX & ProX ®EX BlackPrinter Compatibility ProX ® 6100 sPro™ 60 sPro™ 140 sPro™ 230 ProX ® 500DuraForm ® EX Natural Printer Compatibility ProX ® 6100xsPro™ 60 sPro™ 140 sPro™ 230ProX ® 500xDuraForm ® PA & ProX ® PA Printer Compatibility ProX ® 6100 sPro™ 60 sPro™ 140 sPro™ 230 ProX ® 500DuraForm ® FR1200 Printer Compatibility ProX ® 6100 sPro™ 60 sPro™ 140 sPro™ 230 ProX ® 500DuraForm ® ProX ® AF+ Printer Compatibility ProX ® 6100sPro™ 60x sPro™ 140x sPro™ 230xProX ® 500DuraForm ® GF & ProX ® GF Printer Compatibility ProX ® 6100 sPro™ 60 sPro™ 140 sPro™ 230 ProX ® 500DuraForm ® HST & ProX ® HSTPrinter Compatibility ProX ® 6100 sPro™ 60 sPro™ 140 sPro™ 230 ProX ® 500DuraForm ® TPU Printer Compatibility ProX ® 6100xsPro™ 60sPro™ 140x sPro™ 230x ProX ® 500xDuraForm ® FLEX Printer Compatibility ProX ® 6100xsPro™ 60sPro™ 140x sPro™ 230x ProX ® 500xDuraForm ® FLEX Printer Compatibility ProX ® 6100xsPro™ 60sPro™ 140x sPro™ 230x ProX ® 500xFlexible / durable High elongationHigh impact strengthFlexible / durable High elongationHigh impact strengthFlexible / durable High elongation High-impact strength Food gradeMedical gradeImpact and fatigue resistant plastic for harsh environments. Available in Natural and Black.Tough, impact-resistant natural colored thermoplastic for prototypes and end-use parts.Strong, tough Nylon 12 for production parts.FAR 25.853 and UL 94-V2 compliant flame retardant Nylon 12 plastic with excellent surface finish.High stiffness, aluminum-filled Nylon 12 with metallic appearance.A glass-filled engineering plastic with excellent stiffness.A fiber-reinforced engineering nylon with high temperature resistance.Thermoplastic elastomer material with rubber-like flexibility and functionality.Durable, rubber-like material.Styrene-based, expendable pattern casting material, compatible with most standard foundry processes.Selective Laser Sintering - Expand your manufacturing capabilities with production-grade materialsDownload this free eBook to help you make the best decision for your SLS application. This guide will assist you in choosing exactly the right material combination for your production part.• Choose from 10 production-grade materials for robust repeatable parts • Discover the unique benefits of each material and learn about their applications• Find out who else is using the materials and learn from their experienceElastomeric / rubber-likeHigh elongationElastomeric / rubber-likeHigh elongationShort burnout cycleMATERIAL TYPE Nylon 11Nylon 12Thermoplastic PolystyreneMATERIAL COLOUR Black WhiteOff-whiteMetallic greyNEW!NEW!Download eBookMATERIAL PROPERTIES Stiff / rigid Flexible / durable Elastomeric / rubber-like High temperature resistance High elongation High impact strength Food grade Medical grade Flame retardantShort burnout cycleSelective Laser SinteringExpand your manufacturing capabilities with production-grade materialsThe Ultimate 3D Manufacturing Solution。

FAST SLS 900WH 数字行李秤 用户手册说明书

FAST SLS 900WH 数字行李秤 用户手册说明书

User's manual ESLS 900WHBefore fi rst use, please read all instructions contained in this user manual carefully, even if you are already familiar with using similar products. Only use this product in accordance with the instructions described in the user manual. Keep the user's manual in a safe place where it can be easily retrievedfor future use.Save the original packaging, material, warranty card and proof of purchase receipt, at least for the duration of the warranty policy. If you need to ship this product, pack it in the original cardboard boxto ensure maximum protection during shipping or transport (e.g., when moving or when you need to send this product for repair).E SLS 900WHCONTENTSIMPORTANT SAFETY NOTICE (3)INTRODUCTION (4)OPERATI ON (4)MAINTENANCE AND CLEANING (5)TROUBLESHOOTING (5)DISPOSAL OF USED BATTERIES (5)TECHNICAL SPECIFICATIONS (5)DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT (6)INSTRUCTIONS AND INFORMATION REGARDING THE DISPOSAL OF USED PACKAGING MATERIALS (6)SLS 900WH EIMPORTANT SAFETY NOTICE1) Carefully unpack the product and take care not to throw away any part of the packaging beforeyou fi nd all the parts of the product.2) This product must not be used by persons (including children) with mental disabilities, weakstrength or by inexperienced persons, unless properly trained or schooled in the safe use of the product, or unless they have been properly supervised by a qualifi ed person who will be responsible for their safety.3) Children must be supervised to ensure that they do not play with the appliance.4) Under no circumstances should you try to repair or alter the product on your own — danger ofelectric shock! Entrust all repairs and adjustments to a specialised company/service. If you open the product during the warranty period, you run the risk of voiding the warranty.5) Only store and use the product away from fl ammable or volatile materials and solutions.6) Keep the product away from extreme temperatures, direct sunlight and excessive humidity. Do notuse in a dusty environment.7) Do not place the appliance near heaters, open fi res and other sources of heat.8) This product is designed for household use. Do not use in industrial surroundings or outdoors!9) Do not use the product for purposes other than those intended.10) Do not spray the product with water or any other liquid. Do not pour water or any other liquidsinto the product. Do not submerge the product in water or any other liquid.11) If you will not be using the product for an extended period of time, remove the batteries. Other-wise they may leak inside the product and cause irreparable damage.12) T he manufacturer is not responsible for damages caused by incorrect use of this appliance or itsaccessories. Such damages include food spoilage, injuries, burns, scalding, fi re, etc.E SLS 900WHINTRODUCTIONThis digital travel luggage scale is used primarily for weighing luggage when travelling by airplane and prevents unpleasant situations where it is necessary to pay signifi cant surcharges for luggage that is over the weight limit set by the airline companies.It can, however, also be used for weighing parcels, fruit and vegetables in buckets during harvesttime, etc.OPERATION1) Pull the nylon strap through the handle of the luggage that you wish to weigh.2)3) Press the button on the scale. The display will show …8888” and the selected weight measuringunit. While the …8888” symbol is shown on the screen you can repeatedly press the button to change the weight measuring unit (kg --> st --> lb).4) After about two second the scale will be ready for weighing (…0.0” will be shown on the display).5) Now carefully lift the scale together with the luggage in such a way that no part of the luggage istouching the ground or the mat that it is on.WarningWhile weighing, hold the scale in a horizontal position and watch the display as you lift it so asnot to overload it by a piece of luggage that is too heavy.6) After measuring the weight of the weighed item, the measuring unit will fl ash twice and remain7) Turn off the scale by holding down the button for 3 seconds.Protection against overloadThis scale is equipped with a sensor against overload. If any overload occurs, the display will show the warning symbol ”EEEE“.Automatic shut off functionYour scale is equipped with an automatic shut off function. This function will turn the scale off if no activities are detected within 30 seconds.SLS 900WH E Switching between weight unitsYour scale is equipped with a weight unit switch, which enables you to display the weight in different units. If you want to switch between metric (kilograms) and imperial units (pounds or stones), move the switch on the rear of the scale to the applicable position (kg --> st --> lb). The change in units will be shown on the display of the scale.Note1 lb (pound) = 0,45 kg1 st (stone) = 6,35 kgChanging the batteryIf “Lo“ is displayed, you need to replace the battery.Using a cross head screwdriver, unscrew the battery compartment cover located on the underside of the scale and replace the battery with a new one. Ensure to maintain the correct polarity (the positive poleof the battery must always point in the upward direction).MAINTENANCE AND CLEANINGTo clean the outer parts of the scale, use a soft cloth dipped in lukewarm water. Do not use harsh clean-ing fl uids, paint thinners or solvents. These can damage the surface of the appliance.TROUBLESHOOTINGIf the scale is displaying random values or if it is not turning off automatically, you need to restart it.In such cases, remove the battery for about 10 seconds and place it back again. The scale should startto work normally.DISPOSAL OF USED BATTERIESThis product comes with an alkaline battery. Used batteries do not belong in domestic waste.Instead, use the appropriate waste collection and recycling centres.TECHNICAL SPECIFICATIONSPower supply ................................................................................................... 3V lithium battery (CR2032) Measuring range ..............................................................................................................................0 – 50 kg Resolution ..............................................................................................................................................100 g Switching between weight units ...........................................................................................kg --> lb --> st Visible display size .......................................................................................................................62 x 29 mm Dimensions (w x d x h) .......................................................................................................149 x 30 x 47 mm Weight .....................................................................................................................................................95 gE SLS 900WH。

纽姆型滑动滑杆系列(SLS SLF)说明书

纽姆型滑动滑杆系列(SLS SLF)说明书

Mini slides SLS/SLF2d Internet: /catalogue/...Subject to change – 2023/10Mini slides SLS/SLFKey featuresGeneral • Double-acting drives • Precise and rigid guide • Versatile air connections •Sensors can be integrated• Highly flexible thanks to versatile assembly and mounting options on:– Drive body – Slide – Yoke plateMini slide SLS• Slim design• Integrated end-position cushioning:– Elastic cushioning componentsMini slide SLF• Flat design• Adjustable end-position cushioning – Elastic cushioning components• Versatile combination options on:– Drives• System product for handling and assembly technologyPiston diameter Width (W) x Height (H)6 mm 46 x 11 mm 10 mm 48 x 15 mm 16 mm62x21 mm32023/10 – Subject to changed Internet: /catalogue/...Mini slides SLS/SLFKey featuresVersatile Mini slide SLSMini slide SLF22531534[1] Mounting surface:The drive can be directly attached via through-holes or threaded holes (with appropriate screws).[2] Mounting surface:Devices and loads can be directly attached via threaded holes in the slide and the yoke plate (with appropriate screws).[3] Versatile air connections[4] Adjustable end-position cushioning systems on SLF-...-P-Awith elastic cushioning components in the end positions [5] Sensors can be integrated Sensor slots for one or more proximity switches SME/SMT-10. For space-saving, reliable sensing of piston positions. Proximity switches canbe freely moved and clamped in the sensor slots provided.Mini slides SLSType codes4d Internet: /catalogue/...Subject to change – 2023/1052023/10 – Subject to changed Internet: /catalogue/...Mini slides SLSPeripherals overview21Mini slides SLSData sheet-N- Diameter6 ... 16 mm -T-Stroke length5 ... 30 mm -É-1)Must be throttled externally.1)Note operating range of proximity switches.1)Loads moved by the slides must be taken into consideration when calculating the end-position cushioning energy.2)Note also the graph illustrating piston speed as a function of payload a page 86d Internet: /catalogue/...Subject to change – 2023/1072023/10 – Subject to changed Internet: /catalogue/...Mini slides SLSData sheetMaterialsSectional view14532Mini slides SLSData sheetPiston speed v as a function of payload mSLS-6/-10/-16-...-P-AThe indicated torques refer to thecentre of the guide.These values must not be exceededduring dynamic operation. Specialattention must be paid to thedeceleration phase.If the drive is simultaneously subject-ed to several of the forces and torquesffff vvvv=�FFFF yyyy1�FFFF yyyy2+|FFFF zzzz1|FFFF zzzz2+|MMMM xxxx1|MMMM xxxx2+�MMMM yyyy1�MMMM yyyy2+|MMMM zzzz1|MMMM zzzz2≤1indicated below, the following equa-tion must be satisfied in addition tothe indicated maximum loads:Position of the guide centre+ plus stroke length8d Internet: /catalogue/...Subject to change – 2023/10Mini slides SLSData sheetL21 = 36 mm from tableF y= 0 NF z= m x g= 0.495 kg x 9.81 m/s2 = 4.856 NM x= m x g x L y= 0.495 kg x 9.81 m/s2 x 20 mm = 0.097 NmM y= m x g x [(L21+Hub)-L x]= 0.495 kg x 9.81 m/s2 [(36 mm + 20 mm) – 5 mm] = 0.248 Nm M z= 0 Nm Combined load:ffff vvvv=�FFFF yyyy1�FFFF yyyy2+|FFFF zzzz1|FFFF zzzz2+|MMMM xxxx1|MMMM xxxx2+�MMMM yyyy1�MMMM yyyy2+|MMMM zzzz1|MMMM zzzz2≤1=0+ 4,856 NN150 NN+0,097 NNNN1,1 NNNN+0,248 NNNN1,1 NNNN+0=0,345 ≤192023/10 – Subject to change d Internet: /catalogue/...Mini slides SLSData sheet10d Internet: /catalogue/...Subject to change – 2023/10Peripherals overview3132Type codesH- -NoteEnd stops must not be removed.-N- Diameter6 ... 16 mm -T-Stroke length10 ... 80 mm -É-1)Must be throttled externally.1)Note operating range of proximity switches.1)Loads moved by the slides must be taken into consideration when calculating the end-position cushioning energy.2)Note also the graph illustrating piston speed as a function of payload a page 16MaterialsSectional view41352Piston speed v as a function of payload mSLF-6/-10/-16-...-P-Acentre of the guide.These values must not be exceededduring dynamic operation. Specialattention must be paid to thedeceleration phase.If the drive is simultaneously subject-ed to several of the forces and torquesffff vvvv=�FFFF yyyy1�FFFF yyyy2+|FFFF zzzz1|FFFF zzzz2+|MMMM xxxx1|MMMM xxxx2+�MMMM yyyy1�MMMM yyyy2+|MMMM zzzz1|MMMM zzzz2≤1 indicated below, the following equa-tion must be satisfied in addition tothe indicated maximum loads:Position of the guide centre+ plus stroke lengthL21 = 25 mm from tableF y= 0 NF z= m x g= 0.495 kg x 9.81 m/s2 = 4.856 NM x= m x g x L y= 0.495 kg x 9.81 m/s2 x 20 mm = 0.097 NmM y= m x g x [(L21+Hub)-L x]= 0.495 kg x 9.81 m/s2 [(25 mm + 20 mm) – 5 mm] = 0.194 Nm M z= 0 Nm Combined load:ffff vvvv=�FFFF yyyy1�FFFF yyyy2+|FFFF zzzz1|FFFF zzzz2+|MMMM xxxx1|MMMM xxxx2+�MMMM yyyy1�MMMM yyyy2+|MMMM zzzz1|MMMM zzzz2≤1=0+ 4,856 NN150 NN+0,097 NNNN1,1 NNNN+0,194 NNNN1,1 NNNN+0=0,297 ≤1Mini slides SLF Data sheet21 2023/10 – Subject to change d Internet: /catalogue/...Mini slides SLS/SLFAccessories1)Scope of delivery: 10 per pack22d Internet: /catalogue/...Subject to change – 2023/10Mini slides SLF AccessoriesAdapter kit HAPS Material:Wrought aluminium alloyRoHS-compliantH--NoteThe kit includes the individualmounting interface as well as thenecessary mounting material.1)Corrosion resistance class CRC 1 to Festo standard FN 940070Low corrosion stress. Dry internal application or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions).2)Packaging unit quantity.23 2023/10 – Subject to change d Internet: /catalogue/...。

SL-SLS 水流开关 说明书

SL-SLS 水流开关 说明书

SL-SL-SLSSLS 水流开关概述用于感受流过管道的液体流量的变化,起到断流保护。

根据不同的流量需要,开关可以进行调节。

本开关采用的是大负载单刀双掷(SPDT )微动开关,具有快速动作的特点,确保了开关的瞬时性。

外壳设计采用全密封结构,内部构件选用不锈钢耐腐蚀材料,确保开关在任何环境下正常工作。

流体温度0~120℃。

流量开关流向片的调整方法SL-SLS 出厂时装有可拆卸的1英寸、2英寸、3英寸及附加的6英寸流向片,如果需要其它尺寸,可按模板修剪流向片,其圆弧与管道相配。

流量开关一定要安装到一段直线管道上,其两边至少有5倍管径的直线行程。

开关安装时,其接线端子应在易于接线的位置。

SL-SLS 流量开关不能遭受水击,如在流量开关下游装有快速闭合阀,必须使用合适的节流器。

流量开关可安装在水平管道或液流方向向上的垂直管道中,但不能安装在液流向下的管道中。

当安装在液流向上的管道时,因需要考虑重力影响,开关应调节到略高于典型流注析:①“*”根据管的尺寸计算流量值。

②“+”GPM值使用于6″流向片。

对于4″和5″水管,将6″流向片作相应修正。

③“**”开关动作参考开关动作图。

调节流量开关步骤:第一步:取下SL-SLS外壳第二步:调高流量值,顺时针旋转调节螺丝。

想调低流量值,逆时针旋转调节螺丝。

第三步:通过按动主杠杆数次,发现杠杆回复时没有“咔嗒”声表明流量开关低于初设定值。

注:开关已出厂设定约为最小流量值,(参见典型流量表)。

不得调至出厂设定值,因为这有可能造成开关不能回复到“无液流”的位置。

流量开关流向片的调整安装示意图。

SLSC-12201 32通道数字输入 输出模块说明书

SLSC-12201 32通道数字输入 输出模块说明书

SPECIFICA TIONSSLSC-1220132 Channel, 5 V to 33 V, Digital Input/OutputSLSC module design specification version 1.0SLSC compatibility level1Rear I/O compatibility category[01] (digital input/output up to 32 channels) Recommended RTI RTI-12301Front I/O CharacteristicsNote The 32 front I/O channels are organized into two banks consisting of twoports with eight channels per port. Port0 and Port1 are in Bank0; Port2 and Port3 arein Bank1. At least one Vsup must be present and routed to the banks. Each bank canbe powered by either Vsup_0 or Vsup_1.Note The mapping between the 32 rear I/O channels and the 32 front I/O channelsis one-to-one. DIO0 maps to P0.0, and DIO31 maps to P3.7.Number of channels32 bidirectional channelsOvervoltage protection±60 VSynchronization jitter±12.5 nsExternal supply voltage (Vsup) 5 V DC to 33 V DCUndervoltage lockout at 4 VPower-on configuration Software configurable (factory default issinking digital input)Table 1. Feature Configurability (Continued)Digital InputInput type Sinking or sourcingInput voltage range0 V to 5 V0 V to 33 VThreshold voltage settling time20 msMinimum pulse width100 nsMaximum signal frequency100 kHzPropagation delay200 nsSourcing input pull-up resistor24 kΩDigital OutputOutput type Sourcing, sinking, or push-pull Continuous output current50 mA maximumOutput impedance sourcing30 ΩOutput impedance sinking20 ΩShort circuit protection10 channels simultaneous fault Minimum pulse width100 nsMaximum signal frequency100 kHzPropagation delay300 nsRise/fall time25 ns (push-pull configuration) Maximum load capacitance 1 nF maximum2| | SLSC-12201 SpecificationsRear I/O CharacteristicsConnector XJ3 connects to an NI digital input/digital output device supporting 5 V TTL or 3.3 V LVTTL signaling.Power RequirementsPower consumption from backplane 4.1 W maximum5.7 W maximumPower consumption from Vsup under noloadMinimum Vsup power supply outputcurrent capability 1.0A+50mA×BBB BBBBℎBBBThermal dissipation< 50 WPhysical CharacteristicsSLSC slots1Dimensions175 mm × 31 mm × 336 mm (6.89 in. × 1.19in. × 13.21 in.)Weight581 g (20.5 oz)Front I/O connectors2x 44-pin high-density D-SUBRear I/O connectors1x 110-pin Hard Metric type A. 1x 8-bladeUniversal Power Module (UPM), capable ofimplementing Fully Compatible Rear I/O Safety VoltagesMeasurement category OIsolationChannel-to-channel NoneChannel-to-earth ground NoneCaution Do not connect the SLSC-12201 to signals or use for measurementswithin Measurement Categories II, III, or IV.Note Measurement Categories CAT I and CAT O are equivalent. These test andmeasurement circuits are for other circuits not intended for direct connection to theSLSC-12201 Specifications| © National Instruments| 3MAINS building installations of Measurement Categories CAT II, CAT III, orCAT IV.Caution Do not operate the SLSC-12201 in a manner not specified in thisdocument. Product misuse can result in a hazard. You can compromise the safetyprotection built into the product if the product is damaged in any way. If the productis damaged, return it to NI for repair.SafetyThis product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:•IEC 61010-1, EN 61010-1•UL 61010-1, CSA C22.2 No. 61010-1Note For UL and other safety certifications, refer to the product label or the OnlineProduct Certification section.Electromagnetic CompatibilityThis product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:•EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity•EN 55011 (CISPR 11): Group 1, Class A emissions•EN 55022 (CISPR 22): Class A emissions•EN 55024 (CISPR 24): Immunity•AS/NZS CISPR 11: Group 1, Class A emissions•AS/NZS CISPR 22: Class A emissions•FCC 47 CFR Part 15B: Class A emissions•ICES-001: Class A emissionsNote In the United States (per FCC 47 CFR), Class A equipment is intended foruse in commercial, light-industrial, and heavy-industrial locations. In Europe,Canada, Australia and New Zealand (per CISPR 11) Class A equipment is intendedfor use only in heavy-industrial locations.Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medicalequipment that does not intentionally generate radio frequency energy for thetreatment of material or inspection/analysis purposes.Note For EMC declarations and certifications, and additional information, refer tothe Online Product Certification section.4| | SLSC-12201 SpecificationsCE ComplianceThis product meets the essential requirements of applicable European Directives, as follows:•2014/35/EU; Low-V oltage Directive (safety)•2014/30/EU; Electromagnetic Compatibility Directive (EMC)EnvironmentalModule operating temperature0 °C to 85 °C1 (Tested in accordance withIEC 60068-2-1 and IEC 60068-2-2)Storage temperature range-40 °C to 85 °C (Tested in accordance withIEC 60068-2-1 and IEC 60068-2-2.) Relative humidity range, operating10% to 90%, noncondensing (Tested inaccordance with IEC-60068-2-78.)Relative humidity range, storage5% to 95%, noncondensing (Tested inaccordance with IEC-60068-2-78.)Pollution degree2Maximum altitude2,000 m (800 mbar)(at 25 °C ambient) Indoor use only.Shock and VibrationOperating shock30 g peak, half-sine, 11 ms pulse (Tested inaccordance with IEC-60068-2-27. MeetsMIL-PRF-28800F Class 2 limits) Operating vibration, random 5 to 500 Hz, 0.3 g rms (Tested in accordancewith IEC-60068-2-64)Non-operating vibration, random 5 to 500 Hz, 2.4 g rms (Tested in accordancewith IEC-60068-2-64. Non-operating testprofile exceeds the requirements ofMIL-PRF-28800F Class 3.) 1The chassis internal ambient temperature may reach 85 °C with all slots at the maximum allowedpower dissipation.SLSC-12201 Specifications| © National Instruments| 5Online Product CertificationRefer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit / certification, search by model number or product line, and click the appropriate link in the Certification column.Worldwide Support and ServicesThe NI website is your complete resource for technical support. At /support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.Visit /services for NI Factory Installation Services, repairs, extended warranty, and other services.Visit /register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European Communities using the manufacturer’s declaration of conformity. This system affords the user protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC for your product by visiting /certification. If your product supports calibration, you can obtain the calibration certificate for your product at /calibration.NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at /support or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the Worldwide Offices section of / niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.Information is subject to change without notice. Refer to the NI T rademarks and Logo Guidelines at /trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at /patents. Y ou can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at /legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONT AINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.© 2017 National Instruments. All rights reserved.377037A-01July 20, 2017。

SICK SLS Visualization Software 快速入门指南说明书

SICK SLS Visualization Software 快速入门指南说明书

Safety Laser Scanner Visualization SoftwareFor microScan3 and outdoorScan3Quickstart GuideQuickstart GuideInhalt1. Display scanner data in 7 steps (3)Step 1 – Connect Scanner (3)Step 1.1 – Power Supply (3)Step 1.2 – Ethernet Cable (3)Step 2 – Set up Ethernet Connection (4)Step 2.1 – Read out IP address using Safety Designer (4)Step 2.2 – Read out IP address on display of safety laser scanner (4)Step 3 – Download Software (4)Step 4 – Preparing SLS Visualization Software (5)Step 4.1 –Edit “executable” file to correct IP address (5)Step 4.2 – Replace IP address (5)Step 4.3 – Save file (6)Step 5 – Preparing the computer for the network connection. (7)Step 6 – Open the SLS Visualization Software (9)Step 7 – SLS Visualization Software is displayed (9)2. Using the SLS Visualization Software on WinCC – Overview (10)WinCC Professional (TIA Portal) (10)WinCC Advanced (TIA Portal) (11)Quickstart Guide – Safety Laser Scanner Visualization Software This document describes the steps to run the SLS Visualization Software for microScan3 and outdoorScan3.Pre-requisites:Windows PC (Win XP and up).o Note 1: The SLS Visualization Software does not run on Windows CE.W indows CE has reached End of Life Support in 2018; therefore SICK cannotprovide the SLS Visualization Software for Windows CE.o Note 2: Many SIEMENS HMI's using TIA Portal are based on Windows / WinCC → therefore many SIEMENS HMI's are supported.Supported devicesAll microScan3 devices - except all microScan3 Core I/O versionsOnly outdoorScan3 Pro EtherNet IP1. Display scanner data in 7 stepsStep 1 – Connect ScannerFirst, connect the safety laser scanner to the HMI or computer on which the SLS Visualization Software is used.Step 1.1 – Power SupplyConnect scanner to power supply with 24V. Find appropriate cables on .As an example, the following cable can be used for power connection for microScan3 ProPROFINET:Step 1.2 – Ethernet CableConnect safety laser scanner to HMI or computer using an Ethernet cable. Find appropriate cables on . As an example following cable can be used for microScan3 Pro PROFINET :Step 2 – Set up Ethernet ConnectionThe next step is to set up the Ethernet Connection. In order to do this the IP address of the safety laser scanner needs to be known. There are two simple ways to read it out.Step 2.1 – Read out IP address using Safety DesignerOpen Safety Designer, connect to device (e.g. by using USB cable) and see address on pageaddressing.Step 2.2 – Read out IP address on display of safety laser scannerUse the Buttons on the Safety Laser Scanner. (Device Info Network IP address)Step 3 – Download SoftwareClick link to download the SLS Visualization Software:- SICK Internal: Download here:https:///pages/viewpageattachments.action?pageId=393349683&preview=/393349683/393349693/microScan3-VISU-Diagnostics_V1-0.rar- SICK External: receive Secureshare Link by your SICK Contact.When the download is finished open the ZIP file as follows:Unpack ZIP file to afolder of choiceStep 4 – Preparing SLS Visualization SoftwareWhen the file is unzipped, following files should be included:Step 4.1 –Edit “executable” file to correct IP addressThe IP address that is programmed must be edited before starting the THE SLS VISUALIZATION SOFTWARE.Step 4.2 – Replace IP addressA window will open in which the specified IP address must be exchanged by the address of the safety laserscanner. If you do not have this IP address then go back to “Step 2”.Right click on the file "Execute_192_168_1_5.bat " allows editing of the file.Replace the pre-programmed IP address with the actual IP address of the scanner.Step 4.3 – Save fileOnce the IP address is set correctly safe the executable with its new name. The name should include the actual IP addressStep 5 – Preparing the computer for the network connection.Using Windows computers the connection may have to set in the Control panel. See steps below.Open Network andSharing Center.Go to …Ethernet“Go to “Properties”Go to …Internetprotocol, Version 4 (TCP/IPv4)“Enter the IP address andsubnet mask. Subnet mask is the same asthe scanner.Note that this is the IP address ofthe HMI VISU, not of thescanner. Thus: Same subnet, nutdifferent IP address, however insame range. Confirm …OK“.Step 6 – Open the SLS Visualization SoftwareOpen the bat file.Step 7 – SLS Visualization Software is displayedOpen the bat file that was created previously with the actual IP address in itThe VISU tool will open and should automatically connect to the safety laser scanner.2. Using the SLS Visualization Software on WinCC – OverviewWinCC (TIA Portal) is available in different variants WinCC Basic, WinCC Comfort, WinCC Advanced and WinCC Professional. In addition, there are the two runtime systems WinCC Runtime Advanced and WinCC Runtime Professional. The difference between the variants lies primarily in the configurable devices.WinCC Professional (TIA Portal)With WinCC Professional the THE SOFTWARE DIAG tool can be opened with an exe file via a c script. To do this the following code must be written into the script.WinCC Advanced (TIA Portal)To start the HMI VISU DIAG tool the following software is needed on WinCC Advanced: The tool can then be implemented into the WinCC advanced software.The tool can now be displayed via WinCC Advanced.The …diag2“-Button, will start the defined eventHere you can choose at which event an actionshould be executed. Under …Program name“ youhave to link the tool you want to open.。

SLS使用说明书

SLS使用说明书
2.SLR series vertical hot-water pump is used for the warming hot-water booster circular system and the heattransport system of production technology in the units where heat-supply systems are available, such as the power station, thermal power station, residual hest utilization, metallurgy, chemistry, textile, wood-processing, paper-making etc. industrial boilers' high-temperature hot-water,the operation temperature is below 120 .
28
installation methods for pump
29
Erection of the pump start and stop of the pump
30
Maintenance of the pump
Failures causes and troubleshooting
30-33
34
Reference table for pipeline loss
PRODUCT FEATURES 1
2
3
4
5
6
,
pact structure, small volume, beautiful outlook. The lower barycenter of the vertical structure which coincides with the center of the pump feet s trengthens the stability of running and the duration.

十二烷基苯磺酸钠

十二烷基苯磺酸钠

十二烷基苯磺酸钠(英文名称:dodecyl benzenesulfonic acid, sodium salt)是一种物质,由C、H、C、Na、O、S等元素组成,也叫做四聚丙烯基苯磺酸钠,白色或淡黄色粉状或片状固体。

溶于水而成半透明溶液。

主要用作阴离子型表面活性剂。

应用阴离子型表面活性剂。

因生产成本低、性能好,因而用途广泛,是家用洗涤剂用量最大的合成表面活性剂,也生产一部分镁、钙等无机盐及三乙醇胺等有机胺盐。

十二烷基苯磺酸钙[27176-87-0]具有优良的乳化性能,是配制各种农药用的混合型乳化剂的重要组成部分。

可由苯与α-烯烃在三氯化铝催化剂下缩合,缩合液经碱洗、水洗后蒸出回收苯,真空蒸馏得到精制烷基苯。

然后用发烟硫酸磺化、白灰中和(在2倍量乙醇中进行),得到十二烷基苯磺酸钙。

用作丙烯酸酯乳液聚合的阴离子乳化剂。

CAS No.:25155-30-0是一种阴离子表面活性剂,其临界胶束浓度为*10-3mol/L烷基苯磺酸钠是黄色油状体,经纯化可以形成六角形或斜方形强片状结晶.具有微毒性,已被国际安全组织认定为安全化工原料,可在水果和餐具清洗中应用。

烷基苯磺酸钠在洗涤剂中使用的量最大,由于采用了大规模自动化生产,价格低廉。

在洗涤剂中使用的烷基苯磺酸钠有支链结构(ABS)和直链结构(LAS)两种,支链结构生物降解性小,会对环境造成污染,而直链结构易生物降解,生物降解性可大于90%,对环境污染程度小。

烷基苯磺酸钠是中性的,对水硬度较敏感,不易氧化,起泡力强,去污力高,易与各种助剂复配,成本较低,合成工艺成熟,应用领域广泛,是非常出色的阴离子表面活性剂。

烷基苯磺酸纳对颗粒污垢,蛋白污垢和油性污垢有显著的去污效果,对天然纤维上颗粒污垢的洗涤作用尤佳,去污力随洗涤温度的升高而增强,对蛋白污垢的作用高于非离子表面活性剂,且泡沫丰富。

但烷基苯磺酸钠存在两个缺点,一是耐硬水较差,去污性能可随水的硬度而降低,因此以其为主活性剂的洗涤剂必须与适量螯合剂配用。

sls小船数显轮中文说明

sls小船数显轮中文说明

sls小船数显轮中文说明SLC小船数显轮(SLC Digital Wheel)是一种新型的中文输入工具,为用户提供更方便、快捷的中文输入体验。

该系统集合了人类语言理解和计算机智能技术,可以根据用户的输入,自动推断出用户要表达的意思,并将其转化为准确的中文文字。

本文将详细介绍SLC小船数显轮的特点、使用方法以及使用该工具的建议,希望能对广大用户有所帮助。

SLC小船数显轮的特点是其用户友好性和智能化。

通过该工具,用户可以像使用手机键盘一样轻松输入中文,并且无需切换输入法或者记忆繁琐的拼音码表。

SLC小船数显轮能够根据用户的输入上下文,智能地推断用户的意图,并为其提供准确的中文文字选择,大大提高了中文输入的准确性和效率。

使用SLC小船数显轮非常简单。

在输入区域中键入中文字符或拼音,工具会根据用户的输入推断可能的意思,并在候选栏中列出相关的中文词组或单词。

用户只需要通过方向键或鼠标点击来选择正确的词语,即可完成输入。

SLC小船数显轮还支持用户自定义词库和个人习惯词汇的添加,以满足个性化的输入需求。

为了更好地使用SLC小船数显轮,用户可以注意以下几点建议。

首先,保持输入的合理流畅,让工具能够更好地理解用户的意图。

其次,充分利用工具提供的上下文推断功能,尽量不要输入重复的内容,以免造成混淆。

此外,及时更新和管理个人的词库,可以让工具更好地适应个人的输入习惯。

总之,SLC小船数显轮是一款智能化、方便、高效的中文输入工具。

其独特的功能和用户友好的设计,使得中文输入变得更加轻松和愉快。

希望用户们能够充分利用SLC小船数显轮的优势,提升中文输入的速度和准确性。

相信随着科技的不断发展,SLC小船数显轮将会越来越智能化,为用户提供更加出色的中文输入体验。

sls小船数显轮中文说明

sls小船数显轮中文说明

sls小船数显轮中文说明摘要:1.泰勒公式的定义和基本形式2.sin(x) 的泰勒公式展开3.泰勒公式的应用正文:1.泰勒公式的定义和基本形式泰勒公式是一种数学公式,用于描述一个可微函数在某一点附近的近似值。

泰勒公式的基本形式为:f(x) ≈ f(a) + f"(a)(x-a) + f""(a)(x-a)^2/2! + f"""(a)(x-a)^3/3! +...+f^n(a)(x-a)^n/n! + Rn(x)其中,f(x) 是可微函数,a 是函数的某一点,f"(a)、f""(a)、f"""(a) 等分别表示函数在点a 的一阶、二阶、三阶导数,n! 表示n 的阶乘,Rn(x) 是泰勒公式的余项。

2.sin(x) 的泰勒公式展开sin(x) 是一个周期性函数,它的泰勒公式展开可以帮助我们在计算和研究正弦函数时得到更精确的结果。

根据泰勒公式,我们可以将sin(x) 展开为:sin(x) ≈ sin(0) + cos(0)(x-0) + (-sin(0))(x-0)^2/2! + (-cos(0))(x-0)^3/3! +...注意到sin(0) = 0,cos(0) = 1,因此上式可以简化为:sin(x) ≈ 1 * x - 0 * (x^2)/2! + 0 * (x^3)/3! - 0 * (x^4)/4! +...即:sin(x) ≈ x - x^3/3! + x^5/5! - x^7/7! +...3.泰勒公式的应用泰勒公式在数学、物理等学科中有广泛的应用。

例如,在数值分析中,泰勒公式可以用来逼近非线性函数的值;在工程领域,泰勒公式可以用来估算复杂函数的近似值,以提高计算精度和效率。

此外,泰勒公式还与许多其他数学概念和方法密切相关,如麦克劳林级数、洛必达法则等。

总之,泰勒公式是一种重要的数学工具,对于理解函数的性质和行为具有重要意义。

MID COM Smartlink SLS 产品说明书

MID COM Smartlink SLS 产品说明书

MID:COM Smartlink SLSBasic Operating Instructions – Single Meter, Multi Product1.Upon entering the customer’s site for a delivery you must decide if you have to fill multiple tanks with the same product and put them on a single ticket. And what will be the first product you are delivering.2. Observe the printer buttons, the lights must be “dancing” or “scrolling” this prompts you that the system is ready to receive aticket. Insert a delivery ticket “fully” into the Smartlink printer module until the printer “clamps” the ticket. If you have to fill multiple tanks with the same product on a single ticket, you now press the “PRINT 1+2” button, and the statement “MULTIPLE TANK DELIVERY AT SINGLE SITE” will be printed on the ticket and the three (3) minute time-out function required by Measurement Canada will be disabled. Engage your PTO and go directly to the meter.If MULTIPLE TANK DELIVERY is not required you do not press any button, you engage your PTO and go directly to the meter for step 3. If you already have a ticket inserted, and want to cancel the multi-tank delivery simply pull the ticket out and then re-insert a new ticket for a regular delivery.3. Now at the MID:COM register you have to select the product you want to dispense (gasoline, diesel etc.). Press the“RESTART” button one or more times until a number other than “0.0” shows. Now press the “PRESET” button until the correct product code appears ( 1 for propane, 2 for diesel / fuel oil, 3 for gas, 4 for lube oil, 5 for methanol, 6 for NH 3 , 7 for JetA and 8 or 9 are blank for future tables). This only needs to be done if the product is different than your last delivery, as the system defaults to the product code of your last delivery.4. To enter a preset amount press the “RESTART” button until “0.0” appears on the register display. Then press and hold the ”PRESET” button until the desired volume is showing. To start from “0.0” again, press the restart button again.If no PRESET is required, go directly to step 4.5.Now press the “START/STOP” button this resets the register to 0.0 and will open the valve to start a delivery. “WAIT FOR THE GREEN AND YELLOW VALVE LIGHTS” to come on. These are located in the upper left corner of the register display. The preset feature is now disabled if it was not selected.“If compartment valves were open prior to you pressing the STOP/START button, that’s OK. Do not open any valve(s), or allow any product to register while the register is resetting or before the green and yellow lights come on.”6.Now open any compartment valve(s) or any manual hose reel valve(s) and deliver product. The three (3) minute time out function begins after the first 10 liters have been dispensed and will time out three (3) minutes after you close the nozzle. The time out will be reset each time you open the nozzle.7. To print your ticket press any print button on the printer module in the cab of the truck. Your number “1” print button will nowbe constantly lit, press the “1” print button once more and your ticket will print.If you insert a ticket and a printer light stays lighted, this indicates that a previous delivery amount has yet to be printed, simply press the lighted button to print this amount. Insert your next ticket to make a regular delivery.print a shift report, simply press the “PRINT 1+2” button and insert a ticket, a shift report will print. 4028 – 7thStreet S.E. Calgary, Alberta T2G-2Y8Phone: (403) 243-1425 Fax: (403) 243-6577 Toll Free: 1-800-921-ACCU (2228) Email:*****************。

sls小船数显轮中文说明

sls小船数显轮中文说明

sls小船数显轮中文说明
(最新版)
目录
1.SLS 小船数显轮简介
2.SLS 小船数显轮的功能特点
3.SLS 小船数显轮的使用方法
4.SLS 小船数显轮的优势与应用场景
正文
一、SLS 小船数显轮简介
SLS 小船数显轮是一款集时尚与科技于一体的创新产品,它采用高精度的传感器和数字显示技术,能够实时显示船体的角度、速度等关键参数,为船模爱好者和航海运动员提供便捷的测量工具。

二、SLS 小船数显轮的功能特点
1.高精度传感器:SLS 小船数显轮内置了高精度的传感器,能够准确测量船体的角度、速度等信息,让使用者随时了解船模的状态。

2.数字显示:通过清晰的数字显示,用户可以直观地看到船模的关键参数,无需进行复杂的计算。

3.耐水设计:SLS 小船数显轮采用了防水设计,可以在水中长时间工作,无需担心因进水导致的设备损坏。

4.便捷安装:该产品采用可拆卸的设计,方便用户安装和拆卸,满足不同场景的使用需求。

三、SLS 小船数显轮的使用方法
1.安装:首先将 SLS 小船数显轮安装到船模上,确保安装牢固。

2.开机:打开设备上的开关,使数显轮进入工作状态。

3.调试:根据实际需求,调整数显轮的参数设置,如角度、速度等。

4.使用:将船模放入水中,观察数显轮上的参数,随时调整船模的状态。

四、SLS 小船数显轮的优势与应用场景
1.优势:SLS 小船数显轮具有高精度、直观显示、防水设计等优点,能够满足船模爱好者和航海运动员的需求。

国家仪器SLSC-12101 March 2017 说明书

国家仪器SLSC-12101 March 2017 说明书

Manufacturer: National InstrumentsBoard Assembly Part Numbers (Refer to Procedure 1 for identification procedure): Part Number and Revision Description143673A-01L or later SLSC-12101 Prototyping ModuleVolatile MemoryTarget Data Type Size BatteryBackupUser1AccessibleSystemAccessibleSanitizationProcedureNone - - - - - - Non-Volatile Memory (incl. Media Storage)Target Data Type Size BatteryBackupUserAccessibleSystemAccessibleSanitizationProcedureUser CPLD image Flash 27k No Yes No Procedure 2 Identification and user data Flash 1 MB No Yes Yes Procedure 31 Refer to Terms and Definitions section for clarification of User and System AccessibleProceduresProcedure 1 – Board Assembly Part Number identification:To determine the Board Assembly Part Number and Revision, look for a marking between Bank 3 and RTI prototyping areas. The Assembly Part Number should be formatted as “P/N: 143673A-01L.Procedure 2 – User CPLD Image:To clear the user CPLD image, plug Altera’s USB Blaster into the JTAG header of the board, and then use Altera’s Quartus 2 programmer software to detect the device and erase it. Refer to Altera’s Quartus 2 manual and NI’s SLSC-12101 manual for more details.Procedure 3 – Identification and User Data Flash:The entire range of the Identification and User Data Flash is user-accessible. To clear its contents, overwrite each sector with 1’s (or pattern of your choice) using the SLSC API in LabVIEW. For an example, refer to the Write NVMEM VI installed with by SLSC driver at "<LabVIEW Directory> \examples\SLSC\Write NVMEM.vi".∙Use the Initialize Session VI from the SLSC palette to start an NVMEM Area session.∙Generate an array of 0xFF bytes which should be the same size of the memory you want to erase.∙Connect this array as the “data” input of a Set NVMEM Bytes VI, use 0 as the data address.∙Commit the NVMEM Area with the Commit VI∙Close the session after doneTerms and DefinitionsCycle Power:The process of completely removing power from the device and its components and allowing for adequate discharge. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.Volatile Memory:Requires power to maintain the stored information. When power is removed from this memory, its contents are lost. This type of memory typically contains application specific data such as capture waveforms.Non-Volatile Memory:Power is not required to maintain the stored information. Device retains its contents when power is removed.This type of memory typically contains information necessary to boot, configure, or calibrate the product or may include device power up states.User Accessible:The component is read and/or write addressable such that a user can store arbitrary information to the component from the host using a publicly distributed NI tool, such as a Driver API, the System Configuration API, or MAX. System Accessible:The component is read and/or write addressable from the host without the need to physically alter the product. Clearing:Per NIST Special Publication 800-88 Revision 1, “clearing” is a logical technique to sanitize data in all User Accessible storage locations for protection against simple non-invasive data recovery techniques using the same interface available to the user; typically applied through the standard read and write commands to the storage device.Sanitization:Per NIST Special Publication 800-88 Revision 1, “sanitization” is a process to render access to “Target Data” on the media infeasible for a given level of effort. In this document, clearing is the degree of sanitization described.。

SLS快速成型机设计毕业设计说明书

SLS快速成型机设计毕业设计说明书

摘要快速成型(RP)技术是近年来倍受学术界和制造业关注的一种先进成型制造技术。

目前世界上占主导地位的5种RP成型方法其基本原理业己完善,针对具体的RP系统如何在不增加昂贵的附加成本的同时,进一步提高成型效率、提高成型件的精度、完善成型件性能以及尽量扩展成型件的适用范围是发展RP技术的重要课题.作者正是基于以上观点,就高分子粉末材料的激光选区烧结(SLS)快速成型技术中的成型精度、成型时间、扫描路径、成型件的后处理及成型件在制模中的应用问题开展了深入的研究。

将所研究结果应用于设计机械结构中,提高成型机工作合理性。

选择性激光烧结工艺(SLS)又称为激光选区烧结。

是借助精确引导的激光束使材料粉末烧结或熔融后凝固形成三维原型或制件。

该工艺方法是由美国得克萨斯大学奥斯丁(Austin)分校的C.R.Dechard于1989年研制成功的。

目前研究SLS的有DTM公司,E.O.S公司,3D Systems公司,北京隆源公司,华中科技大学,华北工学院,南京航空航天大学等。

其中,最早将SLS市场化的是DTM公司。

作者对比DTM,EOS两大公司的经典设计方案,改进设计结构,增强工作性能,试图将新的思想带入到SLS成型机的设计中。

关键词:快速成型,激光选区烧结,成型效率,成型精度The Selective Laser SinterAbstractRapid Prototyping( RP)is an advanced forming and processing technology that is followed with interest by researchers and manufactures in recent years. Now the basic principles of five kinds of RP technology, which dominate in the world, have been integrated. To special RP systems, it is an important subject how to decrease forming time, improve the prototyping precision and extend the utilization area of prototyping without extra expensive cost. Just on the basis of all above opinions, the research on the forming precision, forming time, scanning path, post-treatment and RT of SLS on the high molecular powder materials is preceded. The result of this research has been successfully applied into the system and has great effect on manufacturing qualified parts, also is a foundation of ameliorating this system.The Selective Laser Sinter(SLS) is also named Laser Selectivity Sinter. It can make the datum powder sinter or blend to three-dimensional antitype by dint of exactitude introductory laser. This craftwork is created in 1989 by an American, C.R.Dechard, who lived in the Austin.Now, there are many company studying the SLS in the world, for example , the DTM, E.O.S, 3D Systems. And there are also many company in our country,for instance, Beijing Longyuan Lst., the middle of China science and technology University. But the first company who made the SLS commercial is the DTM.Author would like compare the design blue print of DTM and E.O.S, and improve the design, also try to take a new idea into the SLS.KEYWORDS: Rapid Prototyping, Selective Laser Sintering, forming precision,Forming time毕业设计(论文)原创性声明和使用授权说明原创性声明本人郑重承诺:所呈交的毕业设计(论文),是我个人在指导教师的指导下进行的研究工作及取得的成果。

sls小船数显轮中文说明

sls小船数显轮中文说明

sls小船数显轮中文说明
摘要:
1.产品简介
2.主要功能
3.技术参数
4.使用方法
5.注意事项
6.产品优势
7.应用场景
正文:
SLS 小船数显轮是一款具有高精度和稳定性的测量工具,适用于各种环境下的测量需求。

其主要功能包括:
- 便捷的读数显示:采用数字显示技术,读数直观方便;
- 高精度测量:精确度达到0.01mm,满足高精度测量需求;
- 稳定性能:采用高品质材料制造,具有良好的抗干扰性能,保证测量的稳定性;
- 广泛适用性:适用于各种不同类型的船舶,满足不同场景的测量需求。

技术参数如下:
- 测量范围:0-500mm;
- 精确度:0.01mm;
- 显示方式:LCD 数字显示;
- 电源:2 节AA 电池;
- 工作温度:-10℃~50℃。

使用方法:
1.安装电池:打开电池仓,放入2 节AA 电池;
2.开启测量:按下测量键,显示器将显示当前测量值;
3.读取数据:读取显示器上的数字,即为测量结果;
4.关闭电源:按下电源键,关闭显示器。

注意事项:
1.请勿将数显轮暴露在雨水中或置于潮湿环境中;
2.使用过程中请勿摔打或强烈碰撞数显轮;
3.请定期检查电池性能,确保测量准确性;
4.如发现数显轮有异常情况,请停止使用并联系售后服务。

SLS 小船数显轮具有以下产品优势:
1.高精度测量,满足专业需求;
2.数字显示,读数直观方便;
3.稳定性能,保证测量结果的准确性;
4.广泛适用性,适用于各种类型的船舶。

sls小船数显轮中文说明

sls小船数显轮中文说明

sls小船数显轮中文说明
摘要:
1.SLS 小船数显轮概述
2.SLS 小船数显轮的功能特点
3.SLS 小船数显轮的使用方法
4.SLS 小船数显轮的注意事项
5.总结
正文:
【SLS 小船数显轮概述】
SLS 小船数显轮是一款集实用、便捷、高效于一身的中文显示轮,适用于各种船舶、海事等领域。

该数显轮具有直观的中文显示功能,可以实时显示船舶的各项参数,为船员提供便捷的操作体验。

【SLS 小船数显轮的功能特点】
1.中文显示:SLS 小船数显轮采用中文显示,让船员在操作过程中能够一目了然地掌握船舶的各项参数。

2.实时数据:数显轮能够实时显示船舶的航速、航向、深度等信息,方便船员进行调整。

3.高效操作:SLS 小船数显轮设计简洁,操作便捷,有效提高了船员的工作效率。

4.抗干扰能力强:数显轮具有较强的抗干扰能力,能在各种恶劣环境下正常工作。

【SLS 小船数显轮的使用方法】
1.安装:首先将数显轮安装在船舶的合适位置,以便船员能够方便地查看。

2.开机:打开数显轮的开关,使其进入工作状态。

3.操作:船员可以通过数显轮对船舶进行操控,调整航速、航向等参数。

【SLS 小船数显轮的注意事项】
1.安装时,要确保数显轮固定牢固,避免因震动等原因造成损坏。

2.使用过程中,要保持数显轮的清洁,避免进水、油污等影响显示效果。

3.若出现故障,应立即关闭电源,并及时联系专业人员进行维修。

【总结】
SLS 小船数显轮凭借其实用性、便捷性和高效性,已成为船舶领域的重要辅助设备。

简单日志服务(SLS)控制台操作指南

简单日志服务(SLS)控制台操作指南

简单日志服务(SLS)控制台操作指南目录简单日志服务(SLS)控制台操作指南 (1)概述 (3)1 创建项目空间(Project) (3)2 创建日志类型(Category) (3)3 创建Logtail配置 (5)4 创建机器分组 (6)5 Logtail配置文件应用到机器组 (7)6 实时查询 (7)7 日志数据消费模式管理 (7)8 机器组管理 (8)概述用户可以通过SLS管理控制台对SLS项目空间、日志数据进行各种管理操作。

主要包含的操作对象为:项目空间(Project)、日志类型(Category)。

其中对Category的行为包含日志数据收集模式、日志数据消费模式等。

以下是详细介绍。

1 创建项目空间(Project)开通SLS服务并且是登陆状态,进入SLS管理控制台首页:/,点击创建Project,填写Project名称,请注意命名规则。

以下是已经创建完成的Project页面2 创建日志类型(Category)点击Project名称sample-project,进入Project。

创建Category,注意命名规则。

对于Category来说,有两种消费模式,请根据您的需求选择消费模式,必须至少选择一个。

Category创建完成后,系统会提示您收集日志数据。

如果您使用SLS客户端Logtail进行收集,请选择创建Logtail配置,如果使用API(SDK)接入,选择取消。

对于API(SDK)接入,控制台指南里不进行介绍,以下我们介绍Logtail日志收集方式。

3 创建Logtail配置在该步骤中,涉及到写正则表达式,请参照正则表达式配置文档指定日志目录结构解析日志现在Logtail配置已经完成,接下来要把这些配置应用到需要收集日志的机器上去。

为了方便用户应用到多台机器,SLS定义了机器组的概念。

下面介绍创建机器组、应用配置到机器组。

4 创建机器分组5 Logtail配置文件应用到机器组6 实时查询当Logtail配置文件应用到机器组后,会立即转向实时查询页面,此时日志数据还未写进来,大约两分钟后会看到日志数据。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

02
OPERATION INSTRUCTION FOR SLS SERIES
CHIEF USAGE 1 SLS
80
2 SLR
120 3 SLH
-20 120 4 SLY(YG)
-20 120 5 SLHY
-20 vertical centrifugal pump is used to transport pure-water and other liquids, the physical properties of which are similar to those of pure-water,in industrial and cities'water supply and drainage, high buildings' booster water supply, gardens irrigation, fire-fighting booster, remote water supply, warming systems, circular booster of cold &hot water in bath rooms as well as in competions of equipments, the operation medium temperature is below 80 .
CONTENTS
01
Outline of the product Product features
02
Working conditions Model meaning
03
Chief usage
The configuration of SLS(SLSD) type pump atlas of style
04-05
SLS type pump performance data
06-12
SLSD type pump performance data
13-15
16
SLS(SLSD) type pump dimension figure dimension table
SLS type pump dimension table
MPa,the pressure in static tests is 2.5MPa, please notify
1.6
the pressure for the system at work when ordering and it
should be otherwise noted of the said pressure is larger
17-23
SLSD type pump dimension table
24-25
26
SLS(SLSD) type pump spare parts and installation basic figure table
27
Installation basic drawing and table of dimension for SLS type pump non-isolation
5.Easy to maintain. Not necessary to remove the pipeline for check-out and maintenance, only to take out the nuts on the pump lid, the motor and the driving components.
28
installation methods for pump
29
Erection of the pump start and stop of the pump
30
Maintenance of the pump
Failures causes and troubleshooting
30-33
34
Reference table for pipeline loss
melting medium solid should not be over 0.1% of the unit
volune and the graininess less than 0.2mm. Please notify
at order if the medium to be used with small grain.
2.Easy to mount. Because of the same apertures of both inlet and outlet which also locate on the same central line, the pump can be directly mounted on any part of the pipeline just as a valve. The motor is covered with a rainproof cap so that operation can be done outdoors. Mounting feet are equipped with the pump so that it can be stably mounted.
6.The pump, according to the operation condition of the worksite, may be vertically, horizontally etc. multiways mounted and also according to the requirements for the flow and stroke, mounted in parallel and/or in series to increase the needed flow and stroke.
3.Stable running, low noise, high concentricity of components. Bearings of low noise are used for the motor, the impellers are of best dynamic and static balance, no vibration at running and the environment thus being improved.
OPERATION INSTRUCTION FOR SLS SERIES
OUTLINE OF THE PRODUCT
SLS
IS
ISO
2858
IS
DL
1.5 2400m3/h
8 150m
ABC
250
SLR
SLH
SLY(YG)
SLHY
Model SLS single-stage single-suction vertical centrifugal pump is a high-effective energy-saving product successfully designed by means of adopting the property data of IS model centrifugal pump and the unique merits of vertical pump and strictly in accordance with ISO2858 world standard and the latest national standard and an ideal product to replace IS horizontal pump, DL model pump etc. ordinary pumps.
01
1
Mpa 2
mm 3
95
WORKING CONDITIONS
1.6MPa 0.4MPa
1.6MPa
0.1 40
1.Max.working pressure of pump system is 1.6MPa,
that is to say the pressure at the suction+the stroke 1.6
PRODUCT FEATURES 1
2
3
4
5
6
,
pact structure, small volume, beautiful outlook. The lower barycenter of the vertical structure which coincides with the center of the pump feet s trengthens the stability of running and the duration.
SLS SLS single-stage single-suction vertical centrifugal pump SLR SLR single-stage single-suction vertical hot-water pump SLH SLH single-stage single-suction vertical chemical pump SLY(YG) SLY(YG) single-stage single-suction vertical non-explosive oil pump SLHY SLHY single-stage single-suction vertical non-explosive chemical pump
The flow range is 1.5 2400m3/h and the stroke range 8-150m and there are basic type, by-passtype, A B C cutting type etc. more than 250 specifications. And per the different flow medium and temperature, SLR hot-water pump, SLH chemical pump and SLY(YG) oil pump and SLHY vertical non-explosive chemical pump. etc. Series products. of the same type and same proprty data have been designed and made.
相关文档
最新文档