OMRON NB系列触摸屏联机修改操作说明

合集下载

欧姆龙NB系列触摸屏安装手册

欧姆龙NB系列触摸屏安装手册
第 3 章 系统设置模式
3-1 系统设置模式的显示方法 .......................................... 3-1 3-2 系统设置模式的功能 .............................................. 3-2
第 4 章 触控校正模式
5-3 请求更换 NB 主体 ................................................ 5-28
ቤተ መጻሕፍቲ ባይዱ附录
附录 -1 规格 ....................................................... 附 -1
普通规格 ..................................................................... 附 -1 性能规格 ..................................................................... 附 -1 通信规格 ..................................................................... 附 -2
2
V107-CN5-01TOC.fm Page 3 Thursday, October 13, 2011 1:18 PM
目录
第 5 章 维护保养和故障排除
5-1 维修保养 ........................................................ 5-1 5-2 故障排除和维修保养 .............................................. 5-2

机器人触摸屏通信功能使用说明书

机器人触摸屏通信功能使用说明书
可读可写的设备类型,相当于操作 PLC 的数据寄存器。当读数据时发出的功能码为 03H,当写 数据时发出的功能码为 10H。
该设备类型与 4x 的设备类型属性是一样的。即发出读写的功能码完全一样。不同之处在于,当 为双字时,若 32_bit unsigned 格式的数据,使用 5x 和 4x 两种设备类型分别读取数据时,高字和 低字的位置是颠倒的。若使用 4x 设备类型读到的数据是 0x1234,那么使用 5x 设备类型读取的 数据即为 0x3412。
I
触摸屏通信功能使用说明书
前言
前言
关于本手册
本手册介绍了机器人触摸屏通信功能,并详细叙述了触摸屏通信功能的配置过 程。阅读本文档有助于读者掌握触摸屏通信功能的原理和各种配置信息。
操作前提
在操作机器人前,请务必仔细阅读产品的相关安全说明和操作说明,用户需在了 解安全知识和基础操作知识之后,才可使用机器人触摸屏通信功能。
修订记录累积了每次文档更新的说明。最新版本的文档包含以前所有文档版本的 更新内容。
表 2 本文中使用的标识
版本
发布时间
修改说明
V1.0.0
2022/01/28
第一次正式发布
文档编号及版本 文档相关信息见表 3。 表 3 文档相关信息 文档名称 文档编号 文档版本 软件版本
《触摸屏通信功能使用说明书使用说明书》 UM-S01500000033-002 V1.0.0 2.6.5
注意事项
◼ ARCS 软件版本需使用 2.6.5.220117_rc 及以上版本。 ◼ 若使用威纶通触摸屏,配套软件版本需使用 EBproV60602259_weinview 以上版本
连接方式
完成机器人和控制柜的连接后,使用网线将机器人控制柜的 Ethernet 网口和触摸屏网口连接即可。

庸博伺服和维控触摸屏的RS485通讯使用手册

庸博伺服和维控触摸屏的RS485通讯使用手册

庸博伺服和维控触摸屏的RS485通讯实现一、485通信接口庸博伺服驱动器具有 RS-485 串行通讯功能。

CN3采用双 RJ45 接口,方便多台驱动器的连接。

(需要设置参数FN05和FN07)线号端子记号功能说明1 RS485-A+ RS485数据传输差动+端2 RS485-B- RS485数据传输差动-端4 GND GND庸博伺服器支持 MODBUS RTU 格式;暂不支持 MODBUS ASCII 格式;支持所有参数寄存器的读和部分具有写属性的寄存器写操作。

二、通讯地址参数组通讯地址Pn-0xx 00xxHP n-1xx 01xxHP n-2xx 02xxHP n-3xx 03xxHP n-4xx 04xxHP n-5xx 05xxHF n-xx 06xxH“监控参数”07xxHModbus驱动器都必须预先在参数Fn-05上设定其伺服驱动器站号,上位控制器根据站号对个别的伺服驱动器实施控制。

同时每一台驱动器都必须在参数Fn-07设置通讯协议。

三、庸博伺服和维控触摸屏的RS485通讯实现(以FN05设6101,FN07设0061为例)1.庸博伺服参数设置FN05:6101(伺服站号为1)FN07:0061(数据位8、校验位NONE 、停止位2、MODBUS RTU 模式) 2.打开维控触摸屏软件(Levi Studio),新建工程 3. 点击设置→通讯口配置4.如下图所示,右下角为所选触摸屏型号的接线图,本图RS485管脚定义为1脚为RS485+,6脚为RS485-,5脚为GND ,与伺服硬件接线(庸博伺服为1脚RS485+,2脚为RS485-,4脚为GND )一一对应即可。

Fn-05通讯参数【0-1】通讯站号1~FF Fn-07 【0】通讯速度 0 :4.8Kbps 1 :9.6Kbps 2 :19.2Kbps 3 :38.4Kbps 【1】通讯协议: 6:(8、N 、2)MODBUS RTU 7:(8、E 、1)MODBUS RTU 8:(8、O 、1)MODBUS RTU5.由于伺服站号设为1,则设备站号改为16.点击更改连接,将设备改为ModBus RTU Slave(All Fuction)7. 点击串口参数设置的设置按钮,将连接方式改为RS485,波特率改为9600,停止位为2,数据位为8,校验位为EVEN,点击确定。

OMRON(欧姆龙)交换机操作手册

OMRON(欧姆龙)交换机操作手册

操作手册目录第一章VLAN划分与路由功能设置第二章FRNT环网与链路聚合功能设置第三章Lynx+ 与Redfox 恢复出厂设置第四章3G路由器通信设置第一章 VLAN 划分与路由功能设置一、 样机1、L210-F2G2、L110-F2G3、开关电源4、以太网设备终端5、其他(线缆等)二、 现场应用一(VLAN 划分与OSPF 应用)以上拓扑图说明:由于现场设备数量若干,处于的网段可能不同,且需要相互之间进行通信,此时需要进行VLAN 划分,及跨网段的数据交换(路由功能)。

L210-F2G (适用功能 VLAN+OSPF ) L110-F2G (适用功能 VLAN )本手册根据如上拓扑图进行操作步骤指导,实现PC机(192.168.0.100)能够访问到终端设备A、B、C等。

默认情况下,交换机的出厂IP地址为:192.168.2.200子网掩码:255.255.255.0用户名: admin密码: westermo三、操作步骤1、根据上面的拓扑图先设置上位PC的IP地址192.168.2.100 (保证与交换机先通信上,并根据实际需求更改交换机的配置信息)。

2、通过浏览器登录 192.168.2.200(默认此处为新交换机)进入交换机查看与配置页面,见下图:3、通过Status可查看相关交换机信息,如下图所示:默认密码:westermo4、通过Configuration ,可进行相关功能配置,如下图所示:步骤:Configuration →network →interface →更改当前上位PC 与交换机相连端口的IP 地址(注:此处相连的端口应按照之前规划好的进行连接,便于后面设置)。

5、通过Configuration ,修改交换机IP 地址,如下图所示:修改为:192.168.0.250, 并单击 Apply.5、修改完毕后,由于PC机与交换机的新地址存在冲突,故此时修改上位PC地址,见下图:6、通过浏览器重新登录交换机192.168.0.250,并进行VLAN划分设置,具体见下图:步骤:Configuration→VLAN→VLANs 进行VLAN及端口划分(注:Tagged表示交换机之间或交换机与上位之间的对接设置;Untagged表示交换机与终端设备的接口设置。

欧姆龙触摸屏连接指导书

欧姆龙触摸屏连接指导书

第一步连接数据线NT系列只可连接A口NT31(C)/631(C)系列用NTST软件。

三、备份画面应用程序操作顺序:机器人触摸屏连接指导书一、硬件准备:笔记本电脑、RS232数据线。

(若无232接口,需准备USB转串口线) RS232数据线自制说明:二、软件准备:首先确定触摸屏型号,NS系列用CX-Designer软件,USB 转串口RS232NT系列:对角同时触摸界面进入系统菜单第三步NS系列有多个选择第一步第二步第二步第二步选择传输模式进入传输模式菜单选择工具传送进入传输界面NS系列:程序-OMRON-(CX-One)-(CX-Designer)-(CX-Designer Ver 2.1)NS 系列无需此步操作NT系列通讯设定,选择相应的串口第四步NT系列:程序-OMRON-NTST4.8C-(NT-series Support Tool)第四步NS系列传输设置,选择正确的端口(通过电脑设备管理查看端口名称)NS系列:传输(PT→PC)NT系列:连接-上载(PT→NT支持工具)第六步选择相应的触摸屏PT型号第五步NS系列传输画面:触摸屏PTNS系列传输画面:电脑PC传输完成将文件保存第六步NS系列传输完成画面NT系列传输完成画面第七步NT系列传输画面:触摸屏PT NT系列传输画面:电脑NT支持工具连接-下载(NT支持工具→PT)问题:触摸屏上电和计算机连接后无法下载画面程序,如何处理?原因分析:① 触摸屏方面的原因:a.NS系列,使用CX-Designer软件,在传输设置中选择传输方式串口或者USB等。

使用USB方式下载需要安装USB驱动程序;b.NT31(C)/631(C)系列,使用NTST软件,确认错误日志或者提示信息(PT 类型不匹配),根据提示信息正确修改。

下载时提示“Time Out”,电缆只能插在触摸屏的A口,触摸屏按任意两个对角进入系统菜单,选择传输模式。

前一次下载没有完成就中断,本次不能下载程序,进入系统菜单选择初始化。

OMRONPLCEView触摸屏编程使用说明书

OMRONPLCEView触摸屏编程使用说明书

触摸屏)编程使用说明书文件编号:HN/QF.13-0002-004版本号: A发放编号:持册人:长沙华能自控集团有限公司目录1.OMRON CJ1M系列PLC介绍 (2)1.1.CPU单元(使用CJ1M-CPU13) (3)1.2.通信单元(使用CJ1W-SCU41) (8)1.3.I/O单元 (8)1.4.模块安装及地址分配 (8)2.OMRON PLC常用编程指令 (9)2.1. 梯形图指令 (9)2.2. 位元(B IT)控制指令 (9)2.3. 结束指令(END) (10)2.4. 定时器和计数器指令 (10)2.5. 数据移位元元元指令 (10)2.6. 数据传送指令 (11)2.7. 数据比较指令 (13)2.8. 数据转换指令 (13)2.9. BCD码运算指令 (14)2.10. 二进制元运算指令 (16)2.11. 逻辑指令 (17)2.12. 子程序和中断控制指令 (18)2.13. 串行通信指令(PMCR) (19)3.OMRON PLC程序编辑软件 (19)3.1. CX-P ROGRAMMER中对PLC的初始化设置 (20)3.2. PLC设定 (20)3.3. CX-P ROGRAMMER中对PLC的联机操作 (21)3.4. 程序中各个子程序的用途定义 (21)4.OMRON PLC通信程序编辑软件 (22)4.1. 与PLC通信单元箱地址设定 (22)4.2. 4-2PLC协议编制软件(CX-P ROTOCOL)通信口设定 (22)4.3. PLC协议编制软件使用简单说明 (23)4.4. PLC与单元箱通信协议注意事项: (23)5.EASYVIEW触摸屏程序编辑软件 (23)5.1. 与OMRON PLC连接参数设定 (23)5.2. 一般参数设定(通过“编辑――系统参数的一般页进行设定) (24)5.3. 组件功能说明 (24)5.4. 触摸屏程序的下载 (27)5.5. 触摸屏程序调试 (28)6.水机屏PLC程序资料寄存器分配 (28)6.1. PLC内部时钟存放区(D0~D6) (28)6.2. PLC事故资料中转区(D10~D19) (28)6.3. 发生的水机操作、故障、事故报警个数存放区(D20): (29)6.4. 水机状态(遥信量)存放区(D21~D30): (29)6.5. PLC事故存放区:(D4000~D5999)共存放200条事故资料 (29)6.6. PLC与单元箱通信辅助中间寄存器: (29)6.7. PLC与单元通信中断判断辅助寄存器: (29)6.8. PLC与HMI(触摸屏)间固定使用寄存器: (30)6.9. 触摸屏及后台操作定义(无特殊要求) (31)7.触摸屏模拟量显示设定 (32)8.OMRON PLC通信协议 (33)8.1. PLC使用 (33)8.2. 对时使用 (34)8.3. 单元箱使用 (34)8.4. PLC通信协议接线图 (38)1.OMRON CJ1M系列PLC介绍当前水机自动化屏大多使用OMRON CJ1M系列PLC,这种PLC为模块式,而且没有底板。

OMRON NB-series 可编程终端操作说明手册说明书

OMRON NB-series 可编程终端操作说明手册说明书

Cat. No. V23I-E-01NB-seriesNB3Q-TW01BNB5Q-TW01BNB7W-TW01BNB10W-TW01BProgrammable Terminals©OMRON, 2013All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of OMRON.No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this instruction is subject to change without notice. Every precaution has been taken in the preparation of this instruction.Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.NB-seriesNB3Q-TW01BNB5Q-TW01BNB7W-TW01BNB10W-TW01BProgrammable TerminalsWeb Interface Operating Instruction Manual September 2013IntroductionThis instruction describes only the configuration and settings required to use NB Web Interface.Please be sure to read and fully understand related manuals including NB-series manual beforeusing the NB series Programmable Terminal, and read this instruction when using NB Web Interface.Copyright and TrademarkSystem names and product names used in this instruction are the trademarks or registeredtrademarks of their respective companies.Notation and TerminologyIndicate the additional information on operation, descriptions or settings.2NB-series Programmable Terminals Web Operating Instruction Manual (OMSQ-ISV(01) 0362(3/21)ContentsIntroduction (2)Contents (3)1 Overview (4)1-1 What is NB Web Interface? (4)1-2 What NB Web Interface Can Do (5)1-3 Operating Environments (6)1-3-1 Necessary NB Series Configuration (6)1-3-2 Necessary Network Environments (6)1-3-3 Necessary Web Browser (6)2 Using NB Web Interface (7)2-1 Connection Method (7)2-1-1 PT Settings (7)2-1-2 Connecting a Web Browser to a PT (7)3 The Functions of NB Web Interface (9)3-1 A List of the Functions of NB Web Interface (9)3-2 Menu Screen (10)3-3 Monitor Screen (11)3-3-1 Monitor Screen (11)3-3-2 Updating a Screen Display (11)3-3-3 Specifying the Display Image Format of the Monitor Screen (12)3-3-4 Not Using the User Authentication (12)3-4 Operation Screen (13)3-4- 1 Operation Screen (13)3-4-2 Reloading Screen Display (14)4 NB Web Interface Settings (15)4-1 NB Web Interface Settings (15)4-1-1 Configuration Screen (15)4-1-2 NB Web Interface Settings (16)5 Authentication settings (18)5-1 Change user name and password (18)5-2 Default user name and password Restoration (18)6 Troubleshooting (19)6-1 Error Messages (19)Revision History List (20)NB-series Programmable Terminals Web Operating Instruction Manual(OMSQ-ISV(01) 0362(3/21))31 OverviewThis section describes an overview of the functions of NB Web Interface. This also describes the OperatingEnvironments for NB Web Interface.1-1 What is NB Web Interface?NB Web Interface is a function that monitors a screen that an NB-series HMI displays using a web browser on apersonal computer connected via Ethernet to an NB-series HMI (Programmable Terminal called “the PT”).NB Web Interface has the following functions.Monitors a PT screen at the site using a web browser.Operates a PT screen at the site using a web browser.4NB-series Programmable Terminals Web Operating Instruction Manual (OMSQ-ISV(01) 0362(3/21)1-2 What NB Web Interface Can DoThis section contains the usage examples of NB Web Interface.Remote MonitoringNB Web Interface allows users to check error and alarm details displayed on the PT by accessing the enduser’s PT from a web browser. Also when users instruct an operator, users can check work done by theoperator using a web browser.Remote OperationUser can access the PT using a web browser. From a web browser, it is possible to remote control the PT. NB-series Programmable Terminals Web Operating Instruction Manual(OMSQ-ISV(01) 0362(3/21))51-3 Operating EnvironmentsThe following shows the system configuration for connecting a PT on a network to a personal computer usingNB Web Interface.1-3-1 Necessary NB Series ConfigurationNB-series PT ModelsAny of the following NB-series is required to use NB Web Interface.NB Model Lot No.09X13M or aboveNB3Q-TW01BNB5Q-TW01BNB7W-TW01BNB10W-TW01BWhen the NB model above do not have web server function, please use NB-Manager version 1.30 or above toupdate the kernel and file system, for operation detail, please refer to [4-4 System Operate] of NB seriesNB-Designer Operation Manual.NB Designer VersionThe following version of the system program must be installed in your NB-series in order to use the NB WebInterface.NB Designer Version ( including NB Manager)Version 1.30 or later*In the NB-Manager, if there is “Web Interface Operation” option on the left side, it means this NB-Managersupports web server function.*For download the application programs, please access your local Omron website, If local site cannot be found,please access Omron IA global site "/ "at first and select the area where you are.1-3-2 Necessary Network EnvironmentsYour NB-series must be able to be connected to a personal computer via one of the following Ethernet standardin order to use the NB Web Interface.Standard10Base-T or 100Base-TX1-3-3 Necessary Web BrowserThe following web browsers can show a PT screen on a personal computer.Web browserMicrosoft Internet Explorer Ver.8Microsoft Internet Explorer Ver.9Safari (IOS.6x)6NB-series Programmable Terminals Web Operating Instruction Manual (OMSQ-ISV(01) 0362(3/21)2 Using NB Web InterfaceThis section explains how to connect a PT to a web browser on a personal computer using NB Web Interface.2-1 Connection MethodThis section explains a PT how to connect to a web browser on a computer using NB Web Interface. This document uses Windows 8 and Microsoft Internet Explorer Ver.9 as an example. For details on the operating system, the setting of the web browser and operation methods, refer to manuals for each product.2-1-1 PT SettingsTo use NB Web Interface, the following settings must be made in the project of NB.1. Use NB-Designer, open the project which will be download to the PT, add bit button component in theframe, set type to “Alternate” in the bit button property, and set the address to LB9175. 2. Compile and download the project to PT.3. Click the bit button on the PT to switch ON of address LB9175.2-1-2 Connecting a Web Browser to a PTThis section explains how to connect a Web Browser to a PT. 1. Start a web browser. 2. Input the following URL.http://(PT IP Address)/For example, when the PT IP Address is “192.168.0.1”:to 3 The Functions of NB Web Interface .ScreenURLMonitor Screen http://(PT IP Address)/monitor.html Operation Screen http://(PT IP Address)/operation.html Configuration Screen http://(PT IP Address)/config.html Menu Screenhttp://(PT IP Address)/menu.html3. The login screen will be displayed.7NB-series Programmable Terminals Web Operating Instruction Manual (OMSQ-ISV(01) 0362(3/21))ReferenceThe NB Web Interface login uses the Basic Authentication defined by the HTTP.It is possible to set whether to use the user authentication login screen or not when displaying Monitor Screen. Refer to 4 NB Web Interface Settings for the settings. 4. Enter the user name and password.The factory settings for the user name and password are as follows.User name default PassworddefaultReferenceThe user name and password can be changed by NB-Manager, for details please refer to 5 Authentication settings .5. ClickOK Button. The menu screen will be displayed.Item DescriptionMonitorMonitors the screen currently displayed on the PT . OperationMonitors the screen currently displayed on the PT .Operates the PT screen by mouse clicking the web browser.Configuration Make settings related to NB Web Interface.Details on each screen are explained in 3 The Functions of NB Web Interface .ReferenceThe initial screen can be changed by setting. For details on the setting, refer to 4 NB Web Interface Settings .NB-series Programmable Terminals Web Operating Instruction Manual (OMSQ-ISV(01) 0362(3/21)83 The Functions of NB Web InterfaceThis section explains the functions of NB Web Interface.3-1 A List of the Functions of NB Web InterfaceNB Web Interface has the following functions (screens).Detail ContentMenu screen The menu screen of NB Web Interface.Monitor screen Monitors the screen currently displayed on the PT.Operation screen Monitors the screen currently displayed on the PT.Also operates the PT screen by mouse clicking the web browser.Configuration screen Make settings related to NB Web Interface.ReferenceFor Configuration screen, refer to 4 NB Web Interface Settings.The Menu screen displays the following screen.ItemDescriptionMenu screenDisplays a list of the NB Web Interface screens. Clicking will jump to each screen.Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.3-3-1 Monitor ScreenThe Monitor screen is used to display a PT screen.It displays the screen as follow. (e.g.)No.Item Description1Monitor Screen Displays a PT screen.2Latest Captured Displays the date and time when a PT screen was read. ReferenceA PT screen cannot be operated with the Monitor screen.To operate a screen, please enter into the Operation screen.To hide the Latest Captured time, should be set in configuration page. For details on the setting, refer to 4 NB Web Interface Settings.3-3-2 Updating a Screen DisplayThe Monitor Screen periodically reads a screen displayed on the PT and updates the screen in a certain interval set in the Configuration screen. (Default: 15 seconds) For details on the setting, refer to 4 NB Web Interface Settings.3-3-3 Specifying the Display Image Format of the Monitor ScreenNB Web Interface displays a Windows BMP, JPEG or PNG format image of a PT screen on a web browser. To select one of the formats, make a setting in the Configuration screen.ReferenceThe display picture format settings in the Configuration screen will also be used for the Operation screen. 3-3-4 Not Using the User AuthenticationIt is possible to set whether or not to use the user authentication (Login screen display) when directly specifying a URL to open the Monitor screen. For details on the setting, refer to 4 NB Web Interface settings.3-4 Operation Screen3-4-1 Operation ScreenThe Operation screen is used to display the PT screen and operate the screen. The Operation screen displays the following screen. (e.g.)Item DescriptionOperation screenDisplays the PT screen.Allows the user to operate the PT screen by clicking the web browser.ReferenceIt is possible to prohibit operating the PT screen from the PT while operating the PT screen from the Operation screen. For details, refer to 4 NB Web Interface Settings .3-4-2 Reloading Screen DisplayThe Operation screen periodically reads a screen displayed on the PT and updates the display. The reload interval can be set in the Configuration screen (Default: 3 seconds).It is also possible to set the time from when the user mouse clicks until the Operation screen reads a PT screen and updates the display. (Default: 1 second).For details on the setting, refer to 4 NB Web Interface Settings.ReferenceThe Reload Interval in the Monitor screen and Reload Interval in the Operation screen are independent from each other. Thus, they must be set separately.4 NB Web Interface SettingsThis section explains the NB Web Interface settings.4-1 NB Web Interface Settings4-1-1 Configuration ScreenThe Configuration Screen is used to make settings for NB Web Interface. 1. Display the Configuration screen.No. Item Description1 Setting Items Settings for NB Web Interface.For details on the settings, refer to 4-1-2 NB Web Interface Settings . 2 apply Reflects the setting changes in NB Web Interface. 3 save Reflects the setting changes in NB Web Interface. Also saves those changes in the PT. 4 default Returns all settings to the default settings.5resetCancels the setting changes currently being input, and returns to the settings before change.(return to the last valid settings)2. Set each item, then click apply or save button.3. A window stating of configuration done is displayed.4. When three seconds elapsed after “Configuration Done” screen is displayed, the window automaticallydisplays a screen set for Initial Page.4-1-2 NB Web Interface SettingsSetting items in the Configuration screen are explained here.Monitor SettingItem Description Correspondingscreen Reload Interval Set the time from when the Monitor screen reads a PT screenuntil when it next reads the NB screen. Between 2 and 99seconds can be set. (Default: 15 seconds)Monitor screenDisplay Pic Format Set which images format used when a PT screen istransferred. There are three formats can be select: BMP, JPEGand PNG. (Default: BMP)-Checked: Use-Unchecked: Not useWhen PNG images are used, user can set the compressionlevel for PNG formats in the option “Compression Level”.Monitor screen, Operation screenPNG Compression Level Set the compression level for creating PNG data. Between0(Compression non destructive) and 8(Highest compressionrate) can be set. (Default: 3)Only enable when selected PNG format in “Display PicFormat”.Monitorscreen,OperationscreenDisplay Date and Time Set whether to display the date and time when the PT scre enis captured on the bottom of Monitor screen. (Defau lt:Selected)-Checked: Displayed-Unchecked: Not displayedMonitor screenUse Authentication Set whether to use the user authentication or not whenspecifying a URL for Monitor screen. (Default: Unchecked)-Checked: User authentication used-Unchecked: User authentication not usedMonitor screenOperation SettingItem Description CorrespondingscreenReload Interval Set the time from when Monitor screen reads an NB screen t owhen it reads the next NB screen. Between 2 and 99seconds can be set. (Default: 3 seconds)Operation screenDelay After Click Set the time from when mouse is clicked to when an NBscreen is read. Between 0 and 99 seconds can be se t.(Default: 1 second)Operation screenDisable Touch Panel Set whether or not to accept inputs at the PT while theOperation screen is being shown. (Default: Unchecked)-Checked: Not accept touch inputs-Unchecked: Accept touch inputs Operation screen refer :note1note1: If user checked “Disable Touch Panel” option and entered the operation screen in browser then disconnect Ethernet cable, NB will waiting 5min for touch control restoration.Server SettingItem Description Correspondingscreen Page Title Set the web page title of up to 64 characters. (Default: NBWeb Interface name and its version) Only support ASCII.All screensInitial Page Set a screen shown when “http://(PT IP address)/” is specifiedas a URL and when the Configuration screen is clos ed.(Default: Menu)-TCP Port Specify the TCP port number that NB Web Interface u ses.Port numbers 80, 8080, and between 49152 and 65535 ca nbe input. (Default: 80)When this setting is changed, NB Web Interface will cut theconnection, and wait to connect using the specified portnumber.Note: Safari browser cannot use 65535 for port number.All screensUser JavaScript Set whether to use JavaScript for screen reloading andscreen operation. (Default: Checked)-Checked: Use-Unchecked: Not use Monitor scre en, Operation screenReferenceIf an invalid value such as a value out of the range is inputted in any fields in the Configuration screen and the “apply” or “save” button is clicked, the value before change will be set in the corresponding fields. If the TCP Port setting is changed, NB Web Interface will cut the connection temporarily. Specify a port number and re-connect from a web browser.For example, specify a URL as follows:When the PT IP Address is 192.168.0.1 and the set port number is 8080. The URL should be input in browser is: http://192.168.0.1:8080/ (Input “:port number” after the IP address). If 80(default) is set as the port number, it don’t needs to be specified.5 Authentication settings5-1 Change user name and password1. Connect NB terminal to PC then open NB-Manager.2. In NB-Manager select “Web Interface Operation” on the left side, the setting page will be displayed on theright side.3. Input new user name, password, confirm password and click “Save Set”, the new login data has beenregistered in NB.Note: 1. Maximum length of user name and password is 32 char.2. User name and password only support English letters and Arabic numerals.ReferenceFor connecting NB with PC, please refer to chapter 2-3 Connecting of NB-series with PC of NB series Setup Manual.5-2 Default user name and password RestorationIf user wants to restore the default user name and password just click “Default” button then click “Save Set”button.Default login data:User Name defaultPassword default6 TroubleshootingThis section explains the troubleshooting measures when errors occur in NB Web Interface.6-1 Error MessagesThis section describes error messages displayed during using NB Web Interface and their countermeasures.Message Cause Countermeasure401 Authorization Required In the user authentication screen, anincorrect user name or password is entered.Enter the correct user name and password.404 Not Found The specified URL is incorrect.Specify the correct URL.NB Image Cannot properly transfer image data from thePT to a web browser. This occurs due to anexcessive network load or with som ebrowsers.Click Refresh Button on the web browser.Cannotfind server or DNS error An attempt was made to connect to a PTmodel that does not support the NB WebInterface.Cannot connect to a model that does no tsupport the NB Web Interface. Forinformation on models that support the NBWeb Interface, refer to 1-3-1 Necessary NBSeries Configuration.Not set bit register LB9175 to ON.Set bit register LB9175 to ON.The specified IP address in a URL isincorrect.Check the PT IP address. Then specify thecorrect IP address.Othererror messages An excessive load is applied to the networkor PT.Wait a while and try again.19NB-series Programmable Terminals Web Operating Instruction Manual(OMSQ-ISV(01) 0362(3/21))Revision History ListRev Date Revision contents1.002013-09-3 Original Production20NB-series Programmable Terminals Web Operating Instruction Manual (OMSQ-ISV(01) 0362(3/21)Terms and Conditions of SaleCertain Precautions on Specifications and UseOMRON CANADA, INC. • HEAD OFFICEToronto, ON, Canada • 416.286.6465 • 866.986.6766 • OMRON ELECTRONICS DE MEXICO • HEAD OFFICEMéxico DF • 52.55.59.01.43.00 •01-800-226-6766•**************OMRON ELECTRONICS DE MEXICO • SALES OFFICEApodaca,N.L.•52.81.11.56.99.20•01-800-226-6766•**************OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP , Brasil • 55.11.2101.6300 • .brOMRON ARGENTINA • SALES OFFICE Cono Sur • 54.11.4783.5300OMRON CHILE • SALES OFFICE Santiago • 56.9.9917.3920OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300Authorized Distributor:V23I-E-01 04/14 Note: Specifications are subject to change. © 2014 Omron Electronics LLC Printed in U.S.A.Automation Control Systems• Machine Automation Controllers (MAC) • Programmable Controllers (PLC) • Operator interfaces (HMI) • Distributed I/O • Software Drives & Motion Controls• Servo & AC Drives • Motion Controllers & Encoders Temperature & Process Controllers • Single and Multi-loop ControllersSensors & Vision• Proximity Sensors • Photoelectric Sensors • Fiber-Optic Sensors • Amplified Photomicrosensors • Measurement Sensors • Ultrasonic Sensors • Vision SensorsIndustrial Components• RFID/Code Readers • Relays • Pushbuttons & Indicators• Limit and Basic Switches • Timers • Counters • Metering Devices • Power SuppliesSafety• Laser Scanners • Safety Mats • Edges and Bumpers • Programmable Safety Controllers • Light Curtains • Safety Relays • Safety Interlock SwitchesOMRON AUTOMATION AND SAFETY • THE AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu。

OMRON PLC编程器基本操作

OMRON PLC编程器基本操作

OMRON PLC 编程器基本操作一、工作方式选择开关1、RUN方式PLC执行用户程序,用户可通过编程器上的LCD显示屏监视运行过程中的I/O状态、通道状态、系统扫描时间、线路状态以及读出系统故障状态、读用户程序、检索指令和继电器触点。

在RUN方式下,用户不能:对程序进行编辑、修改、插入、删除等操作。

如果PLC系统没有连接编程器、EPROM写入器、打印机等外部设备,PLC在上电后自动选择RUN方式开始执行用户程序。

2、MONITOR方式除具有在RUN方式下全部功能外,可以在PLC运行用户程序的同时强迫I/O状态为复位或置位、改变定时器、计数器的设定值、改变各通道的状态和预置数据。

与RUN方式一样,在MONITOR方式下,用户也不能对程序进行编辑、修改、插入、删除等操作。

3、PROGRAM方式在PROGRM方式下,PLC不能执行用户程序,用户可在该方式下进行读、写用户程序、检验或清除程序、监测I/O状态及各通道数据、检索指令或继电器触点,强迫I/O状态为置位或复位、插入或删除等操作。

如果PLC上连接编程器、EPROM写入器、打印机等外部设备,PLC在上电后自动处于PROGRAM方式开始执行用户程序。

二、键盘(部分)1、操作键PLAY/SET键:程序加载/运行调整、置位键。

SET键用于改变继电器的状态由OFF变为ON或清除内存。

上档键为PLAY键,用于从磁带上读取程序。

REC/RESET键:程序存储/复位键。

RESET键用于改变继电器的状态由ON变为OFF或清除内存。

上档键为REC键,用于向磁带机存储程序。

CHG键:变换键。

用于改变计数器或定时器的当前值。

DM键:数据存储键。

用于输入数据及I/O监控。

CONT/#键:#键用于输入常数,上档为CONT键,用于检索指定的继电器触点。

CH/*键:通道键。

用于指定的通道输入。

三、操作(一)、编程操作方式1开机口令:CLR→MONTR。

要清除屏幕可再按CLR键。

欧姆龙高功能触摸屏常见使用问题

欧姆龙高功能触摸屏常见使用问题

欧姆龙⾼功能触摸屏常见使⽤问题1.NS怎么重装及升级系统程序?需要使⽤CF卡,把编程Designer软件对应的安装⽬录:C:\Program Files\OMRON\CX-One\CX-Designer\RecoverUpdate_6_6下的所有⽂件拷贝到CF卡内,NS断电插⼊CF卡,然后NS上电,NS会⾃动读取,选择升级覆盖系统即可。

2.NS屏幕右下⾓⼀直显⽰“Connecting”,画⾯不显⽰?这个原因是由于NS与PLC没有通信成功,导致的原因如下:①电缆损坏、接线不正确,请检查接线。

②NS、PLC端⼝设置的波特率不⼀致,需要设成⼀致。

③PLC与NS使⽤的协议(HOSTLINK、NTLINK)不⼀致。

3.NT的画⾯怎么转换成NS的画⾯?安装NS编辑软件时⾃动会安装NT31C_631C Conversion Support Tool这个⽂件转换⼯具,⽀持把NT31C_631C-V2版本的NT画⾯数据转换成NS画⾯程序。

4.NS内部控件可以调⽤⾃⼰的图⽚吗?可以的,图⽚格式⽀持BMP、JPEG格式,把⾃⼰的图⽚拷贝到编辑软件的安装⽬录下的BMPfiles⽂件夹。

C:\Program Files\OMRON\CX-One\CX-Designer\intaparts\BMPfiles ⽤三芯的XW2Z-200S-V这根电缆只能传画⾯⽆法传送系统程序,⽽XW2Z-200S-CV的这根电缆既可以传画⾯也能传系统程序。

5.NS怎么显⽰负数?6.NS怎么显⽰⼩数点?①Format:设置整数位、⼩数位②Set Unit&Scale设定标定例:7.NS怎么显⽰浮点数据?⽬前NS系列可以⽀持浮点数据(32位单精度浮点)。

①Display:选择⼗进制(Decimal)②Storage:选择浮点(Real)③Format:选择整数与⼩数的位数8.NS控件(触摸按键、数字输⼊等)设置操作权限?进⼊控件设置属性,选择Password,可以为每个控件任意选择⼀个Level1~Level5的密码(可以最多设置5个密码,密码最⼤为16个字符),初始密码可以通过Set Password 或者通过NS硬件系统菜单内设置。

伟伦触摸屏说明书

伟伦触摸屏说明书

E a s y B u i l d e r500R e l e a s e N o t eVersion 2.6.2 SP1 2005-7-8新增功能:1. 宏指令可以被反编译(但eob一定要是V262 SP1产生的)。

2. 文本库与地址标识符库增加导出/导入CSV文件功能。

修正:1. 更新西门子S7-200 driver,修正V2.6.2的通讯异常状况。

Version 2.6.2 2005-6-22新增功能:1.不需关闭epj档案即可在菜单选择压缩与反编译功能。

2.可反编译eob档案中的文本库。

3.增加导出(Export)与导入(Import)文本库与地址标签库功能,使这两种数据库可重复利用。

4.增加文本库与地址标签库数据排序功能。

5.可更改文本库已建立项目的状态数目。

6.数值输入对象增加对象属性选项页。

7.系统PLC参数的[PLC超时常数]可选择范围更改为0.1 ~ 25.5。

8.新建epj档案的对话框,除了可选择机型外,增加语言选项。

9.增加对象锁定功能,使用者可锁定对象的位置与大小(此时将在对象的右上角出现锁定标记),已锁定对象无法更改位置与大小。

10.在状态区增加显示对象的长度与宽度,在建立与更改对象时,可实时获得对象大小信息。

11.增加颜色编号,与选择颜色有关的对话框皆增加此项功能。

12.对象被点选时,使用ESC控制按键可放弃选择。

13.搭配CTRL按键时可选择多个对象。

14.增加对象长度与宽度检查功能,防范在未知情形下,对象的长或宽度变为0。

15.可自动复制目前状态的文字标签内容至其它状态。

16.提供PLC地址搜寻与置换功能。

17.更改地址标签库中的项目名称时,会自动更改相关对象的索引名称。

18.工作按钮的文字可以使用文本库的内容,并支持多国语言。

19.文本库与地址标签库的名称最多可以使用100个字。

修正:1. 可以反编译使用多国语言内容的eob档案。

2. 为方便使用,PLC控制对象将显示macro名称,代替显示macro编号。

欧姆龙 微型可编程终端 MPT002 操作手册

欧姆龙  微型可编程终端 MPT002 操作手册

OMRON微型可编程终端手册编号: V059-CN5-01MPT002MPT002-G4R-V1MPT002-G4P-V1MPT002-G4R-V2MPT002-G4P-V2MPT002-G4N-V1操作手册1前言承蒙您惠购微型可编程终端MPT系列,谨致谢意。

MPT系列是指在FA生产现场等地所产生的各种信息的微型可编程终端(MPT)。

请在充分理解微型可编程终端的功能和性能等的基础上正确使用。

●读者对象本手册以下述人员为对象而编写。

),且具备电气知识(电气工程师或具备同等知识)·负责引进F A设备的人员;·设计F A系统的人员;·安装,连接F A设备的人员;·管理F A生产现场的人员。

●使用须知·本手册除了对MPT002系列的连接和设定进行说明之外,还介绍了其它必要的信息。

使用前请仔细阅读本手册,充分理解说明内容。

阅读后请妥善保管本手册,以便随时取阅。

●关于“使用时的承诺事项”1.保修内容①保修期本公司产品的保修期为自购买之日或交付至指定场所之日起1年。

②保修范围在上述保修期内因本公司的责任而发生产品故障时,本公司将在产品购买地点免费予以更换或维修。

但当故障原因符合下列情况之一时,则不属于保修范围。

a)未按照产品目录或使用说明书等资料中说明的条件、环境、操作方法使时;b)非本公司产品自身的原因时;c)未经本公司授权而改造或维修时;d)未按照本公司产品应有的方法使用时;e)以本公司产品出厂时的科技水平无法对故障进行预测时;f)因自然灾害等其它非本公司责任的不可抗力而导致故障时。

此外,以上的保修是指对本公司产品单件的保修,因本公司产品故障而造成的损失不属于保修对象。

22.责任限制①因本公司产品而引起的特别损失、间接损失或消极损失,本公司概不负责。

②对于本公司的可编程产品,因非本公司人员编写的程序或由此而产生的后果,本公司概不负责。

3.适用条件①将本公司产品与其它产品组合使用时,请确认适用的标准、法规或限制。

(完整版)最新欧姆龙PLC编程软件CXProgrammer和触摸屏组态软件CXDesigne联机仿真图文教程

(完整版)最新欧姆龙PLC编程软件CXProgrammer和触摸屏组态软件CXDesigne联机仿真图文教程

欧姆龙PLC和HMI触摸屏仿真软件安装使用这是一个PLC和HMI触摸屏联机仿真实例首先我们了解一下PLC仿真技术是基于组态软件的仿真系统实现的原理,在于PLC内部各种继电器的状态与组态软件数据库中数据的链接以及该数据与计算机界面上图形对象的链接。

因PLC控制系统实际输出控制时,是通过输出继电器Y和输出模块去驱动外部执行机构的.外界的控制信号和反馈信号通过输入继电器X进入PLC内部。

而在仿真运行状态时PLC的输出模块与外界是断开的,输出(继电器Y的)信号通过通信线只与组态软件数据库中的数据进行交换,而这些数据又与屏幕(界面)上显示的图形对象有关联。

PLC仿真技术伴随计算机应用技术的发展而来.是对工业生产系统进行分析、诊断和优化的有力工具之一。

有效的设计控制仿真系统,应用于各类实践。

可以起到投资少、效果好、效率高的作用。

仿真系统可以基本真实贴近现场实际控制。

现在工业中PLC和触摸屏应用越来越广泛,仿真技术也给我们带来极大便利。

如果调试,只要我们有一台笔记本电脑躺在床上就可以检验我们设计的程序了。

不受硬件和地点限制。

如果是自学不可能买上一大堆的这些东西。

工控产品价格都是不菲的,我们用仿真技术这是最好选择。

首先我们要知道一件事,CX-Programmer4.0以前版本,基本上不是用模拟器的,从6.1开始,CX-Programmer ,CX-Simulator,CX-Designer等软件集成在CX-ONE里了。

所以好多朋友找不到单独版本高一的配CX-Programmer仿真软件。

就是找到了也仿真不起来。

集成的软件就没有这些问题了。

C X-ONE里包含欧姆龙全系列软件。

最新CX-ONE4.27(支持win7 32/64位)下载地址:(有大量高清视频教程)/item.htm?spm=a1z10.1.w4004-4211718343.6.gyZp0V&id=35631807840我们现把CX-ONE4.27下载下来解压。

NB、NS使用232口连接CP1H进行通讯

NB、NS使用232口连接CP1H进行通讯

NB、NS使用232口连接CP1H进行通讯
实验时间:
实验人员:
实验设备:CP1H-XA40DT-D、直流24V电源、导线、USB连接电缆、NB7W-TW00B、NS15-TX01S-V、XW2Z-200T
实验目的:了解欧姆龙的PLC和触摸屏的基本通信设置。

实验步骤(NB):
1、系统概述,硬件搭建和接线
2、软件设置
3、编程说明
在NB的屏里做一个按钮,地址是对应PLC的100.00,当NB和CP1H通讯上之后,点击按钮,CP1H对应的100.00就会有输出。

4、实验现象:
上电后,触摸屏上会出现如上图的画面,点击按钮,会看到PLC的输出端100.00亮起。

5、实验总结:
①实际连接的通信串口和软件中设置的一定要一一对应;
②实际使用的串口要和设置的串口一致;
实验步骤(NS):
1、系统概述,硬件搭建和接线
用一根XW2Z-200T电缆将NS15-TX01S-V和CP1H-XA40DT-D连接。

2、软件设置
3、编程说明
在NS的屏里做一个按钮,地址是对应PLC的100.00,当NS和CP1H通讯上之后,点击按钮,CP1H对应的100.00就会有输出。

4、实验现象:
上电后,触摸屏上会出现如上图的画面,点击按钮,会看到PLC的输出端100.00亮起。

5、实验总结:
①实际连接的通信串口和软件中设置的一定要一一对应;
②NT-LINK通信,波特率只用两种,高速对应的是115200,标准对应的是38400.。

最新欧姆龙PLC编程软件CX Programmer和触摸屏组态软件CX Designe联机仿真图文教程

最新欧姆龙PLC编程软件CX Programmer和触摸屏组态软件CX Designe联机仿真图文教程

欧姆龙PLC和HMI触摸屏仿真软件安装使用这是一个PLC和HMI触摸屏联机仿真实例首先我们了解一下PLC仿真技术是基于组态软件的仿真系统实现的原理,在于PLC内部各种继电器的状态与组态软件数据库中数据的链接以及该数据与计算机界面上图形对象的链接。

因PLC控制系统实际输出控制时,是通过输出继电器Y和输出模块去驱动外部执行机构的.外界的控制信号和反馈信号通过输入继电器X进入PLC内部。

而在仿真运行状态时PLC的输出模块与外界是断开的,输出(继电器Y的)信号通过通信线只与组态软件数据库中的数据进行交换,而这些数据又与屏幕(界面)上显示的图形对象有关联。

PLC仿真技术伴随计算机应用技术的发展而来.是对工业生产系统进行分析、诊断和优化的有力工具之一。

有效的设计控制仿真系统,应用于各类实践。

可以起到投资少、效果好、效率高的作用。

仿真系统可以基本真实贴近现场实际控制。

现在工业中PLC和触摸屏应用越来越广泛,仿真技术也给我们带来极大便利。

如果调试,只要我们有一台笔记本电脑躺在床上就可以检验我们设计的程序了。

不受硬件和地点限制。

如果是自学不可能买上一大堆的这些东西。

工控产品价格都是不菲的,我们用仿真技术这是最好选择。

首先我们要知道一件事,CX-Programmer4.0以前版本,基本上不是用模拟器的,从6.1开始,CX-Programmer ,CX-Simulator,CX-Designer等软件集成在CX-ONE里了。

所以好多朋友找不到单独版本高一的配CX-Programmer仿真软件。

就是找到了也仿真不起来。

集成的软件就没有这些问题了。

C X-ONE里包含欧姆龙全系列软件。

最新CX-ONE4.27(支持win7 32/64位)下载地址:(有大量高清视频教程)/item.htm?spm=a1z10.1.w4004-4211718343.6.gyZp0V&id=35631807840我们现把CX-ONE4.27下载下来解压。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

第一步:打开软件点击工具—上传工程—下一步。

第二步:进入此界面点击—上传工程按钮。

第三步:填写名称,点击确定,
第四步:填写名称,点击保存。

第五步:输入密码,点击确定。

第六步:上传成功,点击确定。

上传成功的文件,需要反编译处理如下图:
依次选择—反编译处理画面—选择要反编译的文件及确定—选择储存的路径。

—点击反编译按钮。

提示输入密码,输入密码——点击确定。

显示反编译成功,点击确定—下一步,
打开文件如图:
打开工程—选择反编译完成的文件,打开打开后的文件,如下图。

报警内容修改如下图:(事件信息登录的内容是在报警画面框里显示的;报警信息登录的内容是在报警条里流动的)
依次点击—元件—报警—事件信息登录或报警信息登录:
此界面可以添加修改报警信息。

程序下载到触摸屏操作如下图:点击全部编译—点击下载—下一步。

用户数据文件“打勾”,点击“下载”按钮OK。

相关文档
最新文档