美国parker液压教程 (26)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Parker Hannifin GmbH Hydraulic Controls Division Gutenbergstr. 38
41564 Kaarst, Germany Tel.:(+) 2131-513-0 Fax:(+) 2131-513-230Bulletin 3209-M1/UK
Installation Manual Series TDL_H
Design³32 Proportional
Throttle Valve
Contents
1. Introduction (4)
Characteristics (5)
2. Technical Data (5)
Parameters (5)
Block Diagram Valve Electronics (6)
Wiring (6)
EMC (6)
3. Installation (7)
Main Connector (7)
Wiring (7)
4. Switching Circuitry (8)
Block Diagram (8)
Command Input (9)
Diagnostic Output (9)
Position Control (9)
Power Stage (10)
Enable Signal Input (10)
Voltage Monitor (11)
5. Measuring Points (11)
Main (Central) Connector (12)
Diagnostic Sockets (12)
6. Commissioning (12)
Ambient Conditions (12)
Input Circuitry (12)
Enable Signal (13)
Zero Position (13)
7. Service (14)
Test Unit (14)
Trouble Shooting Diagram (15)
8. Ordering Code (16)
1. Introduction
Parker TDL_H proportional throttle valves are equipped with high dynamically powered solenoid actuator and on-board electronics. The valve can be linked to any signal control system (i.e. PLC) by only one central plug and wiring connection.
Characteristics
The valve electronics described in this documen-tation relates to the control of high response throttle valves with solenoids, series TDL_H. The electronics is an integrad part of the valve, unifying various functions necessary for the optimum us-•
Provides a specially designed output power stage for high dynamic control of the soleno-ids
•Constant current control of the solenoids •Overriding pilot and main stage stroke control •Specially developed position transducer for high resolution high dynamic control •Differential input stage
•Diagnostic output for valve stroke •
Enable signal for power output stage
•
Low voltage monitoring of the supply voltage with indicating lights giving operation status (only for size 10 - pilot)
•Standard central plug connection, DIN 43563•Spindle operated trimpots for zero setting equalising
•All electronics completely interchangeable •
Full conformity to the European EMC standards
Electrical
Supply voltage
[VDC]22 (28)
Ripple max. 5% eff.;noninductive Switch-on current
[A] 4.0 for 10mS (typ.)Current consumption max.
[A] 2.0 permanent
Fuse, to be provided externally [A]
2.5 medium time lag
Input signal [V]0 ... ±10 smoothed, noninductive*optional 0 ... ±20mA*
Input impedance [kOhm]200 (at current input 500Ohm)Enable input [VDC]
5...28 / 10mA Hysteresis
< 1%Protection standard I P 54
Connection cable [mm 2]7 x AWG17 shielded Cable length max.[m]
50
Hydraulics Hydraulic fluid Mineral oil or HFC
Viskosity
[mm ²/s]
20...100Fluid temperature max.[°C]
max. +60
General Orientation
optional, Y has always to be tied directly & separately to tank Ambient temperature range [°C]
0 ... +60
2.Technical Data Parameters
age of the valve and leading to an integrated solution. The result is an outstanding dynamic response, permitting the valve to be used in closed loop controls. The integrated electronics carry out the following functions:*max. 30VDC against Pin G (ground)
All the information have been carefully selected and assembled and represents the actual knowledge.