施工现场梁模板(扣件式,梁板立柱共用)计算书
600x1900梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《混凝土结构设计规范》GB 50010-20103、《建筑结构荷载规范》GB 50009-20124、《钢结构设计规范》GB 50017-2003一、工程属性二、荷载设计三、模板体系设计设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 15面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400取单位宽度b=1000mm,按四等跨连续梁计算:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4 q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×1.9)+1.4×2,1.35×(0.1+(24+1.5)×1.9)+1.4×0.7×2]×1=60.75 2kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×1.9]×1=58.988kN/m q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1.9)]×1=48.55kN/m计算简图如下:1、强度验算M max=0.107q1静L2+0.121q1活L2=0.107×58.988×0.0752+0.121×1.764×0.0752=0.037kN ·mσ=M max/W=0.037×106/37500=0.979N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.632q2L4/(100EI)=0.632×48.55×754/(100×5400×281250)=0.006mm≤[ν]=L/400=75/400=0.188mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R5=0.393q1静L+0.446q1活L=0.393×58.988×0.075+0.446×1.764×0.075=1.798kNR2=R4=1.143q1静L+1.223q1活L=1.143×58.988×0.075+1.223×1.764×0.075=5.219kN R3=0.928q1静L+1.142q1活L=0.928×58.988×0.075+1.142×1.764×0.075=4.257kN 标准值(正常使用极限状态)R1'=R5'=0.393q2L=0.393×48.55×0.075=1.431kNR2'=R4'=1.143q2L=1.143×48.55×0.075=4.162kNR3'=0.928q2L=0.928×48.55×0.075=3.379kN五、小梁验算承载能力极限状态:梁底面板传递给左边小梁线荷载:q1左=R1/b=1.798/1=1.798kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3,R4]/b=Max[5.219,4.257,5.21 9]/1=5.219kN/m梁底面板传递给右边小梁线荷载:q1右=R5/b=1.798/1=1.798kN/m小梁自重:q2=0.9×1.35×(0.3-0.1)×0.6/8 =0.018kN/m梁左侧模板传递给左边小梁荷载q3左=0.9×1.35×0.5×(1.9-0.2)=1.033kN/m梁右侧模板传递给右边小梁荷载q3右=0.9×1.35×0.5×(1.9-0.2)=1.033kN/m梁左侧楼板传递给左边小梁荷载q4左=0.9×Max[1.2×(0.5+(24+1.1)×0.2)+1.4×2,1.35×(0.5+(24+1.1)×0.2)+1.4×0.7×2]×(0.55-0.6/2)/2×1=1.06kN/m梁右侧楼板传递给右边小梁荷载q4右=0.9×Max[1.2×(0.5+(24+1.1)×0.2)+1.4×2,1.35×(0.5+(24+1.1)×0.2)+1.4×0.7×2]×((1.1-0.55)-0.6/2)/2×1=1.06kN/m左侧小梁荷载q左=q1左+q2+q3左+q4左 =1.798+0.018+1.033+1.06=3.909kN/m中间小梁荷载q中= q1中+ q2=5.219+0.018=5.237kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右 =1.798+0.018+1.033+1.06=3.909kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[3.909,5.237,3.909]=5.237kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=1.431/1=1.431kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3',R4']/b=Max[4.162,3.379,4.1 62]/1=4.162kN/m梁底面板传递给右边小梁线荷载:q1右'=R5'/b=1.431/1=1.431kN/m小梁自重:q2'=1×(0.3-0.1)×0.6/8 =0.015kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(1.9-0.2)=0.85kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(1.9-0.2)=0.85kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(24+1.1)×0.2)]×(0.55-0.6/2)/2×1=0.69 kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.2)]×((1.1-0.55)-0.6/2)/2×1 =0.69kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=1.431+0.015+0.85+0.69=2.986kN/m中间小梁荷载q中'= q1中'+ q2'=4.162+0.015=4.177kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =1.431+0.015+0.85+0.69=2.986kN/m小梁最大荷载q'=Max[q左',q中',q右']=Max[2.986,4.177,2.986]=4.177kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×5.237×0.82,0.5×5.237×0.22]=0.419kN·mσ=M max/W=0.419×106/54000=7.759N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×5.237×0.8,5.237×0.2]=2.095kNτmax=3V max/(2bh0)=3×2.095×1000/(2×40×90)=0.873N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×4.177×8004/(384×7040×243×104)=1.302mm≤[ν]=l1/400=800/400=2mmν2=q'l24/(8EI)=4.177×2004/(8×7040×243×104)=0.049mm≤[ν]=2l2/400=2×200/400=1mm满足要求!4、支座反力计算承载能力极限状态R max=[qL1,0.5qL1+qL2]=max[5.237×0.8,0.5×5.237×0.8+5.237×0.2]=4.19kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=3.127kN,R2=4.19kN,R3=3.42kN,R4=3.42k N,R5=3.42kN,R6=3.42kN,R7=3.42kN,R8=4.19kN,R9=3.127kN正常使用极限状态R max'=[q'L1,0.5q'L1+q'L2]=max[4.177×0.8,0.5×4.177×0.8+4.177×0.2]=3.342kN同理可得:梁底支撑小梁所受最大支座反力依次为R1'=2.389kN,R2'=3.342kN,R3'=2.715kN,R4'=2. 715kN,R5'=2.715kN,R6'=2.715kN,R7'=2.715kN,R8'=3.342kN,R9'=2.389kN六、主梁验算1、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.454×106/4490=101.087N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算主梁剪力图(kN)V max=8.55kNτmax=2V max/A=2×8.55×1000/424=40.33N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.117mm≤[ν]=L/400=367/400=0.917mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.238kN,R2=15.629kN,R3=15.629kN,R4=0.238kN七、可调托座验算荷载传递至立柱方式可调托座可调托座承载力容许值[N](kN) 30扣件抗滑移折减系数k c 11、扣件抗滑移验算两侧立柱最大受力N=max[R1,R4]=max[0.238,0.238]=0.238kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[R2,R3]=15.629kN≤[N]=30kN满足要求!八、立柱验算1、长细比验算l0=h=1500mmλ=l0/i=1500/15.9=94.34≤[λ]=150长细比满足要求!查表得,φ=0.6342、风荷载计算M w=0.9×φc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.331×0.8×1.52/10=0.068kN·m3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2008,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×1.9)+1.4×0.9×2]×1=54.702kN/m2)小梁验算q1=max{1.621+0.9×1.2×[(0.3-0.1)×0.6/8+0.5×(1.9-0.2)]+0.9×[1.2×(0.5+(24+1.1)×0.2)+ 1.4×0.9×1]×max[0.55-0.6/2,(1.1-0.55)-0.6/2]/2×1,4.703+0.9×1.2×(0.3-0.1)×0.6/8}=4 .719kN/m同上四~六计算过程,可得:R1=0.198kN,R2=14.051kN,R3=14.051kN,R4=0.198kN立柱最大受力N w=max[R1+N边1,R2,R3,R4+N边2]+0.9×1.2×0.1×(3.7-1.9)+M w/l b=max[0.198+0.9×[1.2×(0.5+(24+1.1)×0.2)+1.4×0.9×1]×(0.8+0.55-0.6/2)/2×0.8,14.051,14.051,0.198+0.9×[1.2×(0.5+(24+1.1)×0.2)+1.4×0.9×1]×(0.8+1.1-0.55-0.6/2)/2×0.8]+0.194+0.068/1.1=14.307kNf=N/(φA)+M w/W=14307.223/(0.634×424)+0.068×106/4490=68.368N/mm2≤[f]=205 N/mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011第6.9.7:支架高宽比不应大于3H/B=3.7/6=0.617≤3满足要求,不需要进行抗倾覆验算!十、立柱支承面承载力验算F1=N=14.307kN1、受冲切承载力计算根据《混凝土结构设计规范》GB50010-2010第6.5.1条规定,见下表可得:βh=1,f t=0.858N/mm2,η=1,h0=h-20=100mm,u m =2[(a+h0)+(b+h0)]=800mmF=(0.7βh f t+0.25σpc,m)ηu m h0=(0.7×1×0.858+0.25×0)×1×800×100/1000=48.048kN≥F1=1 4.307kN满足要求!2、局部受压承载力计算根据《混凝土结构设计规范》GB50010-2010第6.6.1条规定,见下表可得:f c=7.488N/mm2,βc=1,βl=(A b/A l)1/2=[(a+2b)×(b+2b)/(ab)]1/2=[(300)×(300)/(100×100)]1/2=3,A ln=ab=10000mm 2F=1.35βcβl f c A ln=1.35×1×3×7.488×10000/1000=303.264kN≥F1=14.307kN满足要求!。
600x1000梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《建筑施工模板安全技术规范》JGJ162-20084、《混凝土结构设计规范》GB 50010-20105、《建筑结构荷载规范》GB 50009-20126、《钢结构设计标准》GB 50017-2017一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 18面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400 验算方式三等跨连续梁截面抵抗矩:W=bh2/6=600×18×18/6=32400mm3,截面惯性矩:I=bh3/12=600×18×18×18/12=291600mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4φc Q1k]×b=1×max[1.2×(0.1+(24+1.5)×1)+1.4×3,1.35×(0.1+(24+1.5)×1)+1.4×0.7×3]×0.6=22.5kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1×1.35×[0.1+(24+1.5)×1]×0.6=20.736kN/mq1活=γ0×1.4×0.7×Q1k×b=1×1.4×0.7×3×0.6=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1)]×0.6=15.36kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×20.736×0.22+0.117×1.764×0.22=0.091kN·mσ=M max/W=0.091×106/32400=2.815N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×15.36×2004/(100×5400×291600)=0.106mm≤[ν]=L/250=200/250=0.8mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×20.736×0.2+1.2×1.764×0.2=4.985kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×15.36×0.2=3.379kN五、小梁验算小梁类型钢管小梁截面类型(mm) Φ48.3×3.0小梁计算截面类型(mm) Φ48×2.8 小梁抗弯强度设计值[f](N/mm2) 205小梁抗剪强度设计值[τ](N/mm2) 125 小梁截面抵抗矩W(cm3) 4.25小梁弹性模量E(N/mm2) 206000 小梁截面惯性矩I(cm4) 10.19面板传递给小梁q1=4.985/0.6=8.309kN/m小梁自重q2=1×1.35×(0.3-0.1)×0.2=0.054kN/m梁左侧楼板及侧模传递给小梁荷载F1=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35 ×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×(0.4-0.6/2)/2×0.2+1×1.35×0.5×(1-0.25)×0.2=0.225kN梁右侧楼板及侧模传递给小梁荷载F2=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×((0.8-0.4)-0.6/2)/2×0.2+1×1.35×0.5×(1-0.25)×0.2=0.225kN正常使用极限状态:面板传递给小梁q1=3.379/0.6=5.632kN/m小梁自重q2=1×(0.3-0.1)×0.2=0.04kN/m梁左侧楼板及侧模传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.25)×(0.4-0.6/2)/2×0.2+1×0.5×(1-0.25)×0.2=0.143kN 梁右侧楼板及侧模传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.25)×((0.8-0.4)-0.6/2)/2×0.2+1×0.5×(1-0.25)×0.2=0.143kN 计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.056×106/4250=13.071N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算小梁剪力图(kN)V max=1.253kNτmax=2V max/A=2×1.253×1000/398=6.297N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算小梁变形图(mm)νmax=0.007mm≤[ν]=L/250=267/250=1.068mm满足要求!4、支座反力计算承载能力极限状态R1=0.374kN,R2=2.365kN,R3=2.365kN,R4=0.374kN正常使用极限状态R'1=0.248kN,R'2=1.6kN,R'3=1.6kN,R'4=0.248kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48.3×3.0 主梁计算截面类型(mm) Φ48×2.8 主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19主梁计算方式三等跨连续梁可调托座内主梁根数 2主梁受力不均匀系数0.6由上节可知P=max[R2,R3]×0.6=1.419kN,P'=max[R2',R3']×0.6=0.96kN主梁计算简图一1、抗弯验算主梁弯矩图一(kN·m)σ=M max/W=0.369×106/4250=86.824N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图一(kN)V max=2.235kNτmax=2V max/A=2×2.235×1000/398=11.231N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图一(mm)跨中νmax=0.318mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.018mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=5.782kN用小梁的支座反力分别代入可得:承载能力极限状态图一立杆2:R2=5.782kN,立杆3:R3=5.782kN立杆所受主梁支座反力依次为:立杆2:P2=5.782/0.6=9.637kN,立杆3:P3=5.782/0.6=9.637kN七、纵向水平钢管验算钢管截面类型(mm) Φ48.3×3.0 钢管计算截面类型(mm) Φ48×2.8钢管截面面积A(mm2) 398 钢管截面回转半径i(mm) 16钢管弹性模量E(N/mm2) 206000 钢管截面惯性矩I(cm4) 10.19 钢管截面抵抗矩W(cm3) 4.25 钢管抗弯强度设计值[f](N/mm2) 205 钢管抗剪强度设计值[τ](N/mm2) 1251414纵向水平钢管计算简图一1、抗弯验算纵向水平钢管弯矩图一(kN·m)σ=M max/W=0.097×106/4250=22.824N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算纵向水平钢管剪力图一(kN)V max=0.589kNτmax=2V max/A=2×0.589×1000/398=2.96N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算纵向水平钢管变形图一(mm)跨中νmax=0.082mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.005mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=1.524kN用小梁两侧的支座反力分别代入可得:承载能力极限状态图一:立杆1:R1=1.524kN,立杆4:R4=1.524kN八、可调托座验算两侧立杆最大受力N=max[R1,R4]=max[1.524,1.524]=1.524kN≤0.85×8=6.8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2,P3]=9.637kN≤[N]=30kN满足要求!九、立杆验算顶部立杆段:l01=kμ1(h d+2a)=1×1.386×(750+2×200)=1594mm非顶部立杆段:l02=kμ2h =1×1.755×1500=2632mmλ=max[l01,l02]/i=2632/16=164.5≤[λ]=210长细比满足要求!顶部立杆段:l01=kμ1(h d+2a)=1.155×1.386×(750+2×200)=1841mm非顶部立杆段:l02=kμ2h =1.155×1.755×1500=3041mmλ=max[l01,l02]/i=3041/16=190.062查表得:φ=0.1992、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1×0.6 ×1.4×(1×0.031×0.8×1.52/10)=0.005kN·m3、稳定性计算R1=1.524kN,P2=9.637kN,P3=9.637kN,R4=1.524kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.4-0.6/2)/2×0.8=4.439kN右侧楼板传递给梁右侧立杆荷载:N边2=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.8-0.4-0.6/2)/2×0.8=4.439kNN d=max[R1+N边1,P2,P3,R4+N边2]+1×1.35×0.15×(3.6-1)=max[1.524+4.439,9.637,9.637,1.524+4.439]+0.527=10.164kNf d=N d/(φA)+M wd/W=10163.905/(0.199×398)+0.005×106/4250=129.505N/mm2≤[f]=205N/mm2满足要求!十、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=3.6/50=0.072≤3满足要求!十一、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.8×0.648=0.518kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.8×1×0.259=0.207kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×3.62×0.518+3.6×0.207=4.105kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j =B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=502×0.8×[0.15×3.6/(0.8×0.8)+0.5]+2×1×50/2=2737.5kN.m≥3γ0M ok =3×1×4.105=12.315kN.M满足要求!十二、立杆地基基础计算地基土类型素填土地基承载力特征值f ak(kPa) 140立杆垫木地基土承载力折减系数m f 1 垫板底面面积A(m2) 0.15立杆底垫板的底面平均压力p=N/(m f A)=10.164/(1×0.15)=67.759kPa≤γu f ak=1.363×140 =190.82kPa满足要求!。
550X1000梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工模板安全技术规范》JGJ162-20083、《混凝土结构设计规范》GB 50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计规范》GB 50017-2003一、工程属性二、荷载设计风荷载参数:三、模板体系设计荷载系数参数表:设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 15面板抗弯强度设计值[f](N/mm2) 17 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5000取单位宽度b=1000mm,按四等跨连续梁计算:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4 q1=γ0×[1.35(G1k+(G2k+G3k)×h)+1.4×φc×Q1k]×b=1.1×[1.35×(0.1+(24+1.5)×1)+1.4×0.9×3]×1=42.174kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1.1×1.35×[0.1+(24+1.5)×1]×1=38.016kN/m q1活=γ0×1.4×φc×Q1k×b=1.1×1.4×0.9×3×1=4.158kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1)]×1=25.6kN/m计算简图如下:1、强度验算M max=0.107q1静L2+0.121q1活L2=0.107×38.016×0.1382+0.121×4.158×0.1382=0.086kN ·mσ=M max/W=0.086×106/37500=2.304N/mm2≤[f]=17N/mm2满足要求!2、挠度验算νmax=0.632q2L4/(100EI)=0.632×25.6×137.54/(100×5000×281250)=0.041mm≤[ν]=L/2 50=137.5/250=0.55mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R5=0.393q1静L+0.446q1活L=0.393×38.016×0.138+0.446×4.158×0.138=2.309kN R2=R4=1.143q1静L+1.223q1活L=1.143×38.016×0.138+1.223×4.158×0.138=6.674kN R3=0.928q1静L+1.142q1活L=0.928×38.016×0.138+1.142×4.158×0.138=5.504kN标准值(正常使用极限状态)R1'=R5'=0.393q2L=0.393×25.6×0.138=1.383kNR2'=R4'=1.143q2L=1.143×25.6×0.138=4.023kNR3'=0.928q2L=0.928×25.6×0.138=3.267kN五、小梁验算承载能力极限状态:梁底面板传递给左边小梁线荷载:q1左=R1/b=2.309/1=2.309kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3,R4]/b =Max[6.674,5.504,6.674]/1= 6.674kN/m梁底面板传递给右边小梁线荷载:q1右=R5/b=2.309/1=2.309kN/m小梁自重:q2=1.1×1.35×(0.3-0.1)×0.55/4 =0.041kN/m梁左侧模板传递给左边小梁荷载q3左=1.1×1.35×0.5×(1-0.12)=0.653kN/m梁右侧模板传递给右边小梁荷载q3右=1.1×1.35×0.5×(1-0.12)=0.653kN/m梁左侧楼板传递给左边小梁荷载q4左=1.1×[1.35×(0.5+(24+1.1)×0.12)+1.4×0.9×3]×(0. 525-0.55/2)/2×1=1.172kN/m梁右侧楼板传递给右边小梁荷载q4右=1.1×[1.35×(0.5+(24+1.1)×0.12)+1.4×0.9×3]×((1 .05-0.525)-0.55/2)/2×1=1.172kN/m左侧小梁荷载q左=q1左+q2+q3左+q4左 =2.309+0.041+0.653+1.172=4.175kN/m中间小梁荷载q中= q1中+ q2=6.674+0.041=6.715kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右 =2.309+0.041+0.653+1.172=4.175kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[4.175,6.715,4.175]=6.715kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=1.383/1=1.383kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3',R4']/b =Max[4.023,3.267,4.023]/1= 4.023kN/m梁底面板传递给右边小梁线荷载:q1右'=R5'/b=1.383/1=1.383kN/m小梁自重:q2'=1×(0.3-0.1)×0.55/4 =0.027kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(1-0.12)=0.44kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(1-0.12)=0.44kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(24+1.1)×0.12)]×(0.525-0.55/2)/2×1=0 .439kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.12)]×((1.05-0.525)-0.55/2) /2×1=0.439kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=1.383+0.027+0.44+0.439=2.29kN/m中间小梁荷载q中'= q1中'+ q2'=4.023+0.027=4.051kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =1.383+0.027+0.44+0.439=2.29kN/m小梁最大荷载q'=Max[q左',q中',q右']=Max[2.29,4.051,2.29]=4.051kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×6.715×0.452,0.5×6.715×0.22]=0.17kN·mσ=M max/W=0.17×106/54000=3.148N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×6.715×0.45,6.715×0.2]=1.511kNτmax=3V max/(2bh0)=3×1.511×1000/(2×40×90)=0.63N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×4.051×4504/(384×7040×243×104)=0.126mm≤[ν]=l1/250=450/ 250=1.8mmν2=q'l24/(8EI)=4.051×2004/(8×7040×243×104)=0.047mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算承载能力极限状态R max=max[qL1,0.5qL1+qL2]=max[6.715×0.45,0.5×6.715×0.45+6.715×0.2]=3.022kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=1.879kN,R2=3.022kN,R3=2.495kN,R4=3.0 22kN,R5=1.879kN正常使用极限状态R max'=max[q'L1,0.5q'L1+q'L2]=max[4.051×0.45,0.5×4.051×0.45+4.051×0.2]=1.823kN 同理可得:梁底支撑小梁所受最大支座反力依次为R1'=1.03kN,R2'=1.823kN,R3'=1.482kN,R4'=1.8 23kN,R5'=1.03kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48×2.7主梁计算截面类型(mm) Φ48×2.7主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.12主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 9.89可调托座内主梁根数 11、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.172×106/4120=41.788N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图(kN)V max=4.27kNτmax=2V max/A=2×4.27×1000/384=22.237N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算主梁变形图(mm)νmax=0.04mm≤[ν]=L/250=350/250=1.4mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.045kN,R2=6.103kN,R3=6.103kN,R4=0.045kN七、可调托座验算荷载传递至立杆方式可调托座可调托座承载力容许值[N](kN) 30扣件抗滑移折减系数k c 11、扣件抗滑移验算两侧立杆最大受力N=max[R1,R4]=max[0.045,0.045]=0.045kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[R2,R3]=6.103kN≤[N]=30kN满足要求!八、立杆验算立杆钢管截面类型(mm) Φ48×2.7立杆钢管计算截面类型(mm) Φ48×2.7钢材等级Q235 立杆截面面积A(mm2) 384回转半径i(mm) 16 立杆截面抵抗矩W(cm3) 4.121、长细比验算l0=h=1600mmλ=l0/i=1600/16=100≤[λ]=210长细比满足要求!查表得:φ=0.5882、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1.1×0.9×1.4×(1×0.028×0.45×1.62/1 0)=0.004kN·m3、稳定性计算R1=0.045kN,R2=6.103kN,R3=6.103kN,R4=0.045kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1.1×[1.35×(0.5+(24+1.1)×0.12)+1.4×0.9×3]×(0. 9+0.525-0.55/2)/2×0.45=2.425kN右侧楼板传递给梁右侧立杆荷载:N边2=1.1×[1.35×(0.5+(24+1.1)×0.12)+1.4×0.9×3]×(0. 9+1.05-0.525-0.55/2)/2×0.45=2.425kNN d=max[R1+N边1,R2,R3,R4+N边2]+1.1×1.35×0.15×(4.3-1)=max[0.045+2.425,6. 103,6.103,0.045+2.425]+0.735=6.838kNf d=N d/(φA)+M wd/W=6838.091/(0.588×384)+0.004×106/4120=31.256N/mm2≤[f]=20 5N/mm2满足要求!九、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=4.3/6.7=0.642≤3满足要求!十、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.9×0.204=0.184kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.9×1.5×0.259=0.35kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×4.32×0.184+4.3×0.35=3.201kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j=B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=6.72×0.9×[0.15×4.3/(0.9×0.9)+0.5]+2×1×6.7/2=59.0 72kN.m≥3γ0M ok =3×1.1×3.201=10.563kN.M满足要求!十一、立杆支承面承载力验算F1=N=6.838kN1、受冲切承载力计算根据《混凝土结构设计规范》GB50010-2010第6.5.1条规定,见下表可得:βh=1,f t=1.001N/mm2,η=1,h0=h-20=100mm,u m =2[(a+h0)+(b+h0)]=800mmF=(0.7βh f t+0.25σpc,m)ηu m h0=(0.7×1×1.001+0.25×0)×1×800×100/1000=56.056kN≥F1=6. 838kN满足要求!2、局部受压承载力计算根据《混凝土结构设计规范》GB50010-2010第6.6.1条规定,见下表可得:f c=10.01N/mm2,βc=1,βl=(A b/A l)1/2=[(a+2b)×(b+2b)/(ab)]1/2=[(300)×(300)/(100×100)]1/2=3,A ln=ab=10000mm 2F=1.35βcβl f c A ln=1.35×1×3×10.01×10000/1000=405.405kN≥F1=6.838kN 满足要求!。
梁模板(扣件式,梁板立柱共用)计算书_20180315_200743360
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工模板安全技术规范》JGJ162-20083、《混凝土结构设计规范》GB 50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计规范》GB 50017-2003一、工程属性二、荷载设计风荷载参数:三、模板体系设计设计简图如下:平面图立面图四、面板验算按三等跨连续梁计算:截面抵抗矩:W=bh2/6=1200×18×18/6=64800mm3,截面惯性矩:I=bh3/12=1200×18×18×18/12=583200mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q1k]×b=1.1×max[1.2×(0.1+(24+1.5)×1.2)+1.4×3,1.35×(0.1+(24+1.5)×1.2)+1.4×0.7×3]×1.2=58.588kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1.1×1.35×[0.1+(24+1.5)×1.2]×1.2=54.707kN/mq1活=γ0×1.4×0.7×Q1k×b=1.1×1.4×0.7×3×1.2=3.881kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1.2)]×1.2=36.84kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×54.707×0.1252+0.117×3.881×0.1252=0.093kN·mσ=M max/W=0.093×106/64800=1.429N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×36.84×1254/(100×5400×583200)=0.019mm≤[ν]=L/250=125/250=0.5mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×54.707×0.125+1.2×3.881×0.125=8.104kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×36.84×0.125=5.066kN五、小梁验算承载能力极限状态:面板传递给小梁q1=8.104/1.2=6.754kN/m小梁自重q2=1.1×1.35×(0.3-0.1)×0.125=0.037kN/m梁左侧楼板传递给小梁荷载F1=1.1×max[1.2 ×(0.5+(24+1.1)×0.18)+1.4×3,1.35 ×(0.5+(24+1.1)×0.18)+1.4×0.7×3]×(0.75-1.2/2)/2×0.125+1.1×1.35×0.5×(1.2-0.18)×0.12 5=0.2kN梁右侧楼板传递给小梁荷载F2=1.1×max[1.2 ×(0.5+(24+1.1)×0.18)+1.4×3,1.35 ×(0.5+(24+1.1)×0.18)+1.4×0.7×3]×((1.5-0.75)-1.2/2)/2×0.125+1.1×1.35×0.5×(1.2-0.18)×0.125=0.2kN正常使用极限状态:面板传递给小梁q1=5.066/1.2=4.221kN/m小梁自重q2=1×(0.3-0.1)×0.125=0.025kN/m梁左侧楼板传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.18)×(0.75-1.2/2)/2×0.125+1×0.5×(1.2-0.18)×0.125=0.111kN 梁右侧楼板传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.18)×((1.5-0.75)-1.2/2)/2×0.125+1×0.5×(1.2-0.18)×0.125=0.111kN计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.117×106/133333=0.874N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算小梁剪力图(kN)V max=1.685kNτmax=3V max/(2bh0)=3×1.685×1000/(2×80×100)=0.316N/mm2≤[τ]=1.232N/mm2 满足要求!3、挠度验算小梁变形图(mm)νmax=0.021mm≤[ν]=L/250=450/250=1.8mm满足要求!4、支座反力计算承载能力极限状态R1=0.558kN,R2=3.031kN,R3=1.381kN,R4=3.031kN,R5=0.558kN 正常使用极限状态R'1=0.341kN,R'2=1.886kN,R'3=0.87kN,R'4=1.886kN,R'5=0.341kN 六、主梁验算主梁自重忽略不计,主梁2根合并,其主梁受力不均匀系数=0.6由上节可知P=max[R2,R3,R4]×0.6=1.819kN,P'=max[R2',R3',R4']×0.6=1.132kN主梁计算简图一主梁计算简图二1、抗弯验算主梁弯矩图一(kN·m)主梁弯矩图二(kN·m)σ=M max/W=0.955×106/4730=201.903N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算主梁剪力图一(kN)主梁剪力图二(kN)V max=5.457kNτmax=2V max/A=2×5.457×1000/450=24.253N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算主梁变形图一(mm)主梁变形图二(mm)跨中νmax=0.162mm≤[ν]=L/250=500/250=2mm满足要求!悬臂端νmax=1.382mm≤[ν]=2l2/250=2×300/250=2.4mm满足要求!4、支座反力计算图一:R max=10.518kN图二:R max=9.141kN用小梁的支座反力分别代入可得:承载能力极限状态图一立杆2:R2=10.518kN,立杆3:R3=4.794kN,立杆4:R4=10.518kN图二立杆2:R2=9.141kN,立杆3:R3=4.166kN,立杆4:R4=9.141kN立杆所受主梁支座反力依次为:立杆2:P2=10.518/0.6=17.53kN,立杆3:P3=4.794/0.6=7.989kN,立杆4:P4=10.518/0.6=17.53kN七、纵向水平钢管验算由小梁验算一节可知P=max[R1,R5]=0.558kN,P'=max[R1',R5']=0.341kN纵向水平钢管计算简图一纵向水平钢管计算简图二1、抗弯验算纵向水平钢管弯矩图一(kN·m)纵向水平钢管弯矩图二(kN·m)σ=M max/W=0.293×106/4730=61.945N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算纵向水平钢管剪力图一(kN)纵向水平钢管剪力图二(kN)V max=1.674kNτmax=2V max/A=2×1.674×1000/450=7.44N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算纵向水平钢管变形图一(mm)纵向水平钢管变形图二(mm)跨中νmax=0.049mm≤[ν]=L/250=500/250=2mm满足要求!悬臂端νmax=0.416mm≤[ν]=2l2/250=2×300/250=2.4mm满足要求!4、支座反力计算图一:R max=3.227kN图二:R max=2.804kN用小梁两侧的支座反力分别代入可得:承载能力极限状态图一:立杆1:R1=3.227kN,立杆5:R5=3.227kN图二:立杆1:R1=2.804kN,立杆5:R5=2.804kN八、可调托座验算1、扣件抗滑移验算两侧立杆最大受力N=max[R1,R5]=max[3.227,3.227]=3.227kN≤1×8=8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2,P3,P4]=17.53kN≤[N]=30kN满足要求!九、立杆验算1、长细比验算l0=h=1200mmλ=l0/i=1200/15.9=75.472≤[λ]=210长细比满足要求!查表得:υ=0.752、风荷载计算M wd=γ0×υc×γQ×Mωk=γ0×υc×γQ×(ζ2×ωk×l a×h2/10)=1.1×0.6×1.4×(1×0.061×0.5×1.22/10)=0.004kN·m3、稳定性计算R1=3.227kN,P2=17.53kN,P3=7.989kN,P4=17.53kN,R5=3.227kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1.1×max[1.2×(0.5+(24+1.1)×0.18)+1.4×3,1.35×(0.5+(24+1.1)×0.18)+0.7×1.4×3]×(0.5+0.75-1.2/2)/2×0.5=1.827kN右侧楼板传递给梁右侧立杆荷载:N边2=1.1×max[1.2×(0.5+(24+1.1)×0.18)+1.4×3,1.35×(0.5+(24+1.1)×0.18)+0.7×1.4×3]×(0.5+1.5-0.75-1.2/2)/2×0.5=1.827kNN d=max[R1+N边1,P2,P3,P4,R5+N边2]+1.1×1.35×0.15×(5.4-1.2)=max[3.227+1.827,17.53,7.989,17.53,3.227+1.827]+0.936=18.466kNf d=N d/(υA)+M wd/W=18465.617/(0.75×450)+0.004×106/4730=55.559N/mm2≤[f]=205N/mm2满足要求!十、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=5.4/8.4=0.643≤3满足要求!十一、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.5×0.449=0.225kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.5×1.5×0.362=0.271kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×5.42×0.225+5.4×0.271=4.739kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j=B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=8.42×0.5×[0.15×5.4/(0.5×0.5)+0.5]+2×1×8.4/2=140. 347kN.m≥3γ0M ok =3×1.1×4.739=15.64kN.M满足要求!十二、立杆地基基础计算立杆底垫板的底面平均压力p=N/(m f A)=18.466/(1×0.15)=123.104kPa≤γu f ak=1.363×350 =477.05kPa满足要求!。
300x700梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《建筑施工模板安全技术规范》JGJ162-20084、《混凝土结构设计规范》GB 50010-20105、《建筑结构荷载规范》GB 50009-20126、《钢结构设计标准》GB 50017-2017一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 18面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400 验算方式三等跨连续梁截面抵抗矩:W=bh2/6=300×18×18/6=16200mm3,截面惯性矩:I=bh3/12=300×18×18×18/12=145800mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4φc Q1k]×b=1×max[1.2×(0.1+(24+1.5)×0.7)+1.4×3,1.35×(0.1+(24+1.5)×0.7)+1.4×0.7×3]×0.3=8.152kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1×1.35×[0.1+(24+1.5)×0.7]×0.3=7.27kN/m q1活=γ0×1.4×0.7×Q1k×b=1×1.4×0.7×3×0.3=0.882kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.7)]×0.3=5.385kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×7.27×0.22+0.117×0.882×0.22=0.033kN·mσ=M max/W=0.033×106/16200=2.05N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×5.385×2004/(100×5400×145800)=0.074mm≤[ν]=L/250=200/250=0.8mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×7.27×0.2+1.2×0.882×0.2=1.811kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×5.385×0.2=1.185kN五、小梁验算小梁类型钢管小梁截面类型(mm) Φ48.3×3.0小梁计算截面类型(mm) Φ48×2.8 小梁抗弯强度设计值[f](N/mm2) 205小梁抗剪强度设计值[τ](N/mm2) 125 小梁截面抵抗矩W(cm3) 4.25小梁弹性模量E(N/mm2) 206000 小梁截面惯性矩I(cm4) 10.19面板传递给小梁q1=1.811/0.3=6.037kN/m小梁自重q2=1×1.35×(0.3-0.1)×0.2=0.054kN/m梁左侧楼板及侧模传递给小梁荷载F1=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35 ×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×(0.4-0.3/2)/2×0.2+1×1.35×0.5×(0.7-0.25)×0.2=0.369kN梁右侧楼板及侧模传递给小梁荷载F2=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×((0.8-0.4)-0.3/2)/2×0.2+1×1.35×0.5×(0.7-0.25)×0.2=0.369kN正常使用极限状态:面板传递给小梁q1=1.185/0.3=3.949kN/m小梁自重q2=1×(0.3-0.1)×0.2=0.04kN/m梁左侧楼板及侧模传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.25)×(0.4-0.3/2)/2×0.2+1×0.5×(0.7-0.25)×0.2=0.214kN 梁右侧楼板及侧模传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.25)×((0.8-0.4)-0.3/2)/2×0.2+1×0.5×(0.7-0.25)×0.2=0.214kN 计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.027×106/4250=6.447N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算小梁剪力图(kN)V max=0.81kNτmax=2V max/A=2×0.81×1000/398=4.071N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算小梁变形图(mm)νmax=0.006mm≤[ν]=L/250=267/250=1.068mm满足要求!4、支座反力计算承载能力极限状态R1=0.057kN,R2=1.353kN,R3=1.353kN,R4=0.057kN正常使用极限状态R'1=0.038kN,R'2=0.86kN,R'3=0.86kN,R'4=0.038kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48.3×3.0 主梁计算截面类型(mm) Φ48×2.8 主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19主梁计算方式三等跨连续梁可调托座内主梁根数 2主梁受力不均匀系数0.6由上节可知P=max[R2,R3]×0.6=0.812kN,P'=max[R2',R3']×0.6=0.516kN主梁计算简图一1、抗弯验算主梁弯矩图一(kN·m)σ=M max/W=0.211×106/4250=49.647N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算主梁剪力图一(kN)V max=1.279kNτmax=2V max/A=2×1.279×1000/398=6.427N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图一(mm)跨中νmax=0.171mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.01mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=3.309kN用小梁的支座反力分别代入可得:承载能力极限状态图一立杆2:R2=3.309kN,立杆3:R3=3.309kN立杆所受主梁支座反力依次为:立杆2:P2=3.309/0.6=5.515kN,立杆3:P3=3.309/0.6=5.515kN七、纵向水平钢管验算钢管截面类型(mm) Φ48.3×3.0 钢管计算截面类型(mm) Φ48×2.8钢管截面面积A(mm2) 398 钢管截面回转半径i(mm) 16钢管弹性模量E(N/mm2) 206000 钢管截面惯性矩I(cm4) 10.19钢管截面抵抗矩W(cm3) 4.25 钢管抗弯强度设计值[f](N/mm2) 205 钢管抗剪强度设计值[τ](N/mm2) 1251414纵向水平钢管计算简图一1、抗弯验算纵向水平钢管弯矩图一(kN·m)σ=M max/W=0.015×106/4250=3.529N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算纵向水平钢管剪力图一(kN)V max=0.09kNτmax=2V max/A=2×0.09×1000/398=0.451N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算纵向水平钢管变形图一(mm)跨中νmax=0.013mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.001mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=0.232kN用小梁两侧的支座反力分别代入可得:承载能力极限状态图一:立杆1:R1=0.232kN,立杆4:R4=0.232kN八、可调托座验算两侧立杆最大受力N=max[R1,R4]=max[0.232,0.232]=0.232kN≤0.85×8=6.8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2,P3]=5.515kN≤[N]=30kN满足要求!九、立杆验算顶部立杆段:l01=kμ1(h d+2a)=1×1.386×(750+2×200)=1594mm非顶部立杆段:l02=kμ2h =1×1.755×1500=2632mmλ=max[l01,l02]/i=2632/16=164.5≤[λ]=210长细比满足要求!顶部立杆段:l01=kμ1(h d+2a)=1.155×1.386×(750+2×200)=1841mm非顶部立杆段:l02=kμ2h =1.155×1.755×1500=3041mmλ=max[l01,l02]/i=3041/16=190.062查表得:φ=0.1992、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1×0.6 ×1.4×(1×0.031×0.8×1.52/10)=0.005kN·m3、稳定性计算R1=0.232kN,P2=5.515kN,P3=5.515kN,R4=0.232kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.4-0.3/2)/2×0.8=5.179kN右侧楼板传递给梁右侧立杆荷载:N边2=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.8-0.4-0.3/2)/2×0.8=5.179kNN d=max[R1+N边1,P2,P3,R4+N边2]+1×1.35×0.15×(3.6-0.7)=max[0.232+5.179,5.515,5.515,0.232+5.179]+0.587=6.102kNf d=N d/(φA)+M wd/W=6102.1/(0.199×398)+0.005×106/4250=78.221N/mm2≤[f]=205N/mm2满足要求!十、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=3.6/72=0.05≤3满足要求!十一、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.8×0.675=0.54kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.8×1×0.259=0.207kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×3.62×0.54+3.6×0.207=4.245kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j =B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=722×0.8×[0.15×3.6/(0.8×0.8)+0.5]+2×1×72/2=5644.8kN.m≥3γ0M ok =3×1×4.245=12.735kN.M满足要求!十二、立杆地基基础计算地基土类型素填土地基承载力特征值f ak(kPa) 140立杆垫木地基土承载力折减系数m f 1 垫板底面面积A(m2) 0.15立杆底垫板的底面平均压力p=N/(m f A)=6.102/(1×0.15)=40.681kPa≤γu f ak=1.363×140 =190.82kPa满足要求!。
300×650梁梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《混凝土结构设计规范》GB 50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计标准》GB 50017-20176、《建筑结构可靠性设计统一标准》GB50068-2018一、工程属性设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 18面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400W=bh2/6=1000×18×18/6=54000mm3,I=bh3/12=1000×18×18×18/12=486000mm4q1=γ0×[1.3(G1k+(G2k+G3k)×h)+1.5×γL×Q2k]×b=1×[1.3×(0.1+(26+1.5)×0.65)+1.5×0.9×2]×1=26.068kN/mq1静=γ0×1.3×[G1k+(G2k+G3k)×h]×b=1×1.3×[0.1+(26+1.5)×0.65]×1=23.368kN/m q1活=γ0×1.5×γL×Q2k×b=1×1.5×0.9×2×1=2.7kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(26+1.5)×0.65)]×1=17.975kN/m计算简图如下:1、强度验算M max=0.1q1静L2+0.117q1活L2=0.1×23.368×0.12+0.117×2.7×0.12=0.027kN·m σ=M max/W=0.027×106/54000=0.491N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×17.975×1004/(100×5400×486000)=0.005mm≤[ν]=L/250=100/250=0.4mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R4=0.4q1静L+0.45q1活L=0.4×23.368×0.1+0.45×2.7×0.1=1.056kNR2=R3=1.1q1静L+1.2q1活L=1.1×23.368×0.1+1.2×2.7×0.1=2.894kN标准值(正常使用极限状态)R1'=R4'=0.4q2L=0.4×17.975×0.1=0.719kNR2'=R3'=1.1q2L=1.1×17.975×0.1=1.977kN五、小梁验算梁底面板传递给左边小梁线荷载:q1左=R1/b=1.056/1=1.056kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3]/b = Max[2.894,2.894]/1= 2.894kN/m梁底面板传递给右边小梁线荷载:q1右=R4/b=1.056/1=1.056kN/m小梁自重:q2=1×1.3×(0.3-0.1)×0.3/3 =0.026kN/m梁左侧模板传递给左边小梁荷载q3左=1×1.3×0.5×(0.65-0.14)=0.332kN/m梁右侧模板传递给右边小梁荷载q3右=1×1.3×0.5×(0.65-0.14)=0.332kN/m梁左侧楼板传递给左边小梁荷载q4左=1×[1.3×(0.5+(26+1.1)×0.14)+1.5×0.9×2]×(0.4-0.3/2)/2×1=1.035kN/m梁右侧楼板传递给右边小梁荷载q4右=1×[1.3×(0.5+(26+1.1)×0.14)+1.5×0.9×2]×((0.8-0.4)-0.3/2)/2×1=1.035kN/m 左侧小梁荷载q左=q1左+q2+q3左+q4左=1.056+0.026+0.332+1.035=2.449kN/m中间小梁荷载q中= q1中+ q2=2.894+0.026=2.92kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右=1.056+0.026+0.332+1.035=2.449kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[2.449,2.92,2.449]=2.92kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=0.719/1=0.719kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3']/b = Max[1.977,1.977]/1= 1.977kN/m梁底面板传递给右边小梁线荷载:q1右'=R4'/b=0.719/1=0.719kN/m小梁自重:q2'=1×(0.3-0.1)×0.3/3 =0.02kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(0.65-0.14)=0.255kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(0.65-0.14)=0.255kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(26+1.1)×0.14)]×(0.4-0.3/2)/2×1=0.537kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(26+1.1)×0.14)]×((0.8-0.4)-0.3/2)/2×1=0.537kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=0.719+0.02+0.255+0.537=1.531kN/m 中间小梁荷载q中'= q1中'+ q2'=1.977+0.02=1.997kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =0.719+0.02+0.255+0.537=1.531kN/m 小梁最大荷载q'=Max[q左',q中',q右']=Max[1.531,1.997,1.531]=1.997kN/m为简化计算,按二等跨连续梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×2.92×0.82,0.5×2.92×0.22]=0.234kN·mσ=M max/W=0.234×106/53333=4.38N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.625ql1,ql2]=max[0.625×2.92×0.8,2.92×0.2]=1.46kNτmax=3V max/(2bh0)=3×1.46×1000/(2×50×80)=0.547N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=0.521q'l14/(100EI)=0.521×1.997×8004/(100×7040×213.333×104)=0.284mm≤[ν]=l1/250=800/250=3.2mmν2=q'l24/(8EI)=1.997×2004/(8×7040×213.333×104)=0.027mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算承载能力极限状态R max=max[1.25qL1,0.375qL1+qL2]=max[1.25×2.92×0.8,0.375×2.92×0.8+2.92×0.2]=2.92 kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=2.449kN,R2=2.92kN,R3=2.92kN,R4=2.449kN正常使用极限状态R max'=max[1.25q'L1,0.375q'L1+q'L2]=max[1.25×1.997×0.8,0.375×1.997×0.8+1.997×0.2] =1.997kN同理可得:梁底支撑小梁所受最大支座反力依次为R1'=1.531kN,R2'=1.997kN,R3'=1.997kN,R4'=1.531kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48×3.5 主梁计算截面类型(mm) Ф48×3.2 主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.73主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 11.36可调托座内主梁根数 11、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.306×106/4730=64.759N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图(kN)V max=4.851kNτmax=2V max/A=2×4.851×1000/450=21.562N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.037mm≤[ν]=L/250=400/250=1.6mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.518kN,R2=9.703kN,R3=0.518kN七、可调托座验算荷载传递至立杆方式可调托座可调托座承载力容许值[N](kN) 30两侧立杆最大受力N=max[R1,R3]=max[0.518,0.518]=0.518kN≤0.85×8=6.8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[R2]=9.703kN≤[N]=30kN满足要求!八、立杆验算l0=h=1500mmλ=l0/i=1500/15.9=94.34≤[λ]=150长细比满足要求!查表得,φ=0.6342、风荷载计算M w=γ0×γL×φw1.5×ωk×l a×h2/10=1×0.9×0.9×1.5×0.362×0.8×1.52/10=0.079kN·m3、稳定性计算R1=0.518kN,R2=9.703kN,R3=0.518kN立杆最大受力N w=max[R1+N边1,R2,R3+N边2]+1×1.3×0.15×(4.5-0.65)+M w/l b =max[0.518+1×[1.3×(0.5+(26+1.1)×0.14)+1.5×0.9×1]×(0.8+0.4-0.3/2)/2×0.8,9.703,0.518+1×[1.3×(0.5+(26+1.1)×0.14)+1.5×0.9×1]×(0.8+0.8-0.4-0.3/2)/2×0.8]+0.751+0.07 9/0.8=10.553kNf=N/(φA)+M w/W=10552.514/(0.634×450)+0.079×106/4730=53.689N/mm2≤[f]=205N/mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011 第6.9.7:支架高宽比不应大于3H/B=4.5/20=0.225≤3满足要求,不需要进行抗倾覆验算!十、立杆地基基础计算f ak 300kPa满足要求!。
300x1900梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《混凝土结构设计规范》GB 50010-20103、《建筑结构荷载规范》GB 50009-20124、《钢结构设计规范》GB 50017-2003一、工程属性二、荷载设计三、模板体系设计设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 15面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400取单位宽度b=1000mm,按四等跨连续梁计算:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4 q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×1.9)+1.4×2,1.35×(0.1+(24+1.5)×1.9)+1.4×0.7×2]×1=60.75 2kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×1.9]×1=58.988kN/m q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1.9)]×1=48.55kN/m计算简图如下:1、强度验算M max=0.107q1静L2+0.121q1活L2=0.107×58.988×0.0752+0.121×1.764×0.0752=0.037kN ·mσ=M max/W=0.037×106/37500=0.979N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.632q2L4/(100EI)=0.632×48.55×754/(100×5400×281250)=0.006mm≤[ν]=L/400=75/400=0.188mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R5=0.393q1静L+0.446q1活L=0.393×58.988×0.075+0.446×1.764×0.075=1.798kNR2=R4=1.143q1静L+1.223q1活L=1.143×58.988×0.075+1.223×1.764×0.075=5.219kN R3=0.928q1静L+1.142q1活L=0.928×58.988×0.075+1.142×1.764×0.075=4.257kN 标准值(正常使用极限状态)R1'=R5'=0.393q2L=0.393×48.55×0.075=1.431kNR2'=R4'=1.143q2L=1.143×48.55×0.075=4.162kNR3'=0.928q2L=0.928×48.55×0.075=3.379kN五、小梁验算承载能力极限状态:梁底面板传递给左边小梁线荷载:q1左=R1/b=1.798/1=1.798kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3,R4]/b =Max[5.219,4.257,5.219]/1= 5.219kN/m梁底面板传递给右边小梁线荷载:q1右=R5/b=1.798/1=1.798kN/m小梁自重:q2=0.9×1.35×(0.3-0.1)×0.3/4 =0.018kN/m梁左侧模板传递给左边小梁荷载q3左=0.9×1.35×0.5×(1.9-0.2)=1.033kN/m梁右侧模板传递给右边小梁荷载q3右=0.9×1.35×0.5×(1.9-0.2)=1.033kN/m梁左侧楼板传递给左边小梁荷载q4左=0.9×Max[1.2×(0.5+(24+1.1)×0.2)+1.4×2,1.35×(0.5+(24+1.1)×0.2)+1.4×0.7×2]×(0.55-0.3/2)/2×1=1.696kN/m梁右侧楼板传递给右边小梁荷载q4右=0.9×Max[1.2×(0.5+(24+1.1)×0.2)+1.4×2,1.35×(0.5+(24+1.1)×0.2)+1.4×0.7×2]×((1.1-0.55)-0.3/2)/2×1=1.696kN/m左侧小梁荷载q左=q1左+q2+q3左+q4左 =1.798+0.018+1.033+1.696=4.545kN/m中间小梁荷载q中= q1中+ q2=5.219+0.018=5.237kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右 =1.798+0.018+1.033+1.696=4.545kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[4.545,5.237,4.545]=5.237kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=1.431/1=1.431kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3',R4']/b =Max[4.162,3.379,4.162]/1= 4.162kN/m梁底面板传递给右边小梁线荷载:q1右'=R5'/b=1.431/1=1.431kN/m小梁自重:q2'=1×(0.3-0.1)×0.3/4 =0.015kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(1.9-0.2)=0.85kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(1.9-0.2)=0.85kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(24+1.1)×0.2)]×(0.55-0.3/2)/2×1=1.10 4kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.2)]×((1.1-0.55)-0.3/2)/2×1 =1.104kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=1.431+0.015+0.85+1.104=3.4kN/m中间小梁荷载q中'= q1中'+ q2'=4.162+0.015=4.177kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =1.431+0.015+0.85+1.104=3.4kN/m小梁最大荷载q'=Max[q左',q中',q右']=Max[3.4,4.177,3.4]=4.177kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×5.237×0.82,0.5×5.237×0.22]=0.419kN·mσ=M max/W=0.419×106/54000=7.759N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×5.237×0.8,5.237×0.2]=2.095kNτmax=3V max/(2bh0)=3×2.095×1000/(2×40×90)=0.873N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×4.177×8004/(384×7040×243×104)=1.302mm≤[ν]=l1/400=800/400=2mmν2=q'l24/(8EI)=4.177×2004/(8×7040×243×104)=0.049mm≤[ν]=2l2/400=2×200/400=1mm满足要求!4、支座反力计算承载能力极限状态R max=[qL1,0.5qL1+qL2]=max[5.237×0.8,0.5×5.237×0.8+5.237×0.2]=4.19kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=3.636kN,R2=4.19kN,R3=3.42kN,R4=4.19k N,R5=3.636kN正常使用极限状态R max'=[q'L1,0.5q'L1+q'L2]=max[4.177×0.8,0.5×4.177×0.8+4.177×0.2]=3.342kN同理可得:梁底支撑小梁所受最大支座反力依次为R1'=2.72kN,R2'=3.342kN,R3'=2.715kN,R4'=3.3 42kN,R5'=2.72kN六、主梁验算1、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.595×106/4490=132.543N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算主梁剪力图(kN)V max=7.346kNτmax=2V max/A=2×7.346×1000/424=34.649N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.131mm≤[ν]=L/400=550/400=1.375mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.48kN,R2=18.111kN,R3=0.48kN七、可调托座验算荷载传递至立柱方式可调托座可调托座承载力容许值[N](kN) 30扣件抗滑移折减系数k c 11、扣件抗滑移验算两侧立柱最大受力N=max[R1,R3]=max[0.48,0.48]=0.48kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[R2]=18.111kN≤[N]=30kN满足要求!八、立柱验算1、长细比验算l0=h=1500mmλ=l0/i=1500/15.9=94.34≤[λ]=150长细比满足要求!查表得,φ=0.6342、风荷载计算M w=0.9×φc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.331×0.8×1.52/10=0.068kN·m3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2008,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×1.9)+1.4×0.9×2]×1=54.702kN/m2)小梁验算q1=max{1.621+0.9×1.2×[(0.3-0.1)×0.3/4+0.5×(1.9-0.2)]+0.9×[1.2×(0.5+(24+1.1)×0.2)+ 1.4×0.9×1]×max[0.55-0.3/2,(1.1-0.55)-0.3/2]/2×1,4.703+0.9×1.2×(0.3-0.1)×0.3/4}=4 .719kN/m同上四~六计算过程,可得:R1=0.423kN,R2=16.152kN,R3=0.423kN立柱最大受力N w=max[R1+N边1,R2,R3+N边2]+0.9×1.2×0.1×(3.7-1.9)+M w/l b=max[ 0.423+0.9×[1.2×(0.5+(24+1.1)×0.2)+1.4×0.9×1]×(0.8+0.55-0.3/2)/2×0.8,16.152,0.42 3+0.9×[1.2×(0.5+(24+1.1)×0.2)+1.4×0.9×1]×(0.8+1.1-0.55-0.3/2)/2×0.8]+0.194+0.068/1.1=16.408kNf=N/(φA)+M w/W=16407.545/(0.634×424)+0.068×106/4490=76.181N/mm2≤[f]=205 N/mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011第6.9.7:支架高宽比不应大于3H/B=3.7/6.85=0.54≤3满足要求,不需要进行抗倾覆验算!十、立柱支承面承载力验算F1=N=16.408kN1、受冲切承载力计算根据《混凝土结构设计规范》GB50010-2010第6.5.1条规定,见下表可得:βh=1,f t=0.858N/mm2,η=1,h0=h-20=100mm,u m =2[(a+h0)+(b+h0)]=800mmF=(0.7βh f t+0.25σpc,m)ηu m h0=(0.7×1×0.858+0.25×0)×1×800×100/1000=48.048kN≥F1=1 6.408kN满足要求!2、局部受压承载力计算根据《混凝土结构设计规范》GB50010-2010第6.6.1条规定,见下表可得:f c=7.488N/mm2,βc=1,βl=(A b/A l)1/2=[(a+2b)×(b+2b)/(ab)]1/2=[(300)×(300)/(100×100)]1/2=3,A ln=ab=10000mm 2F=1.35βcβl f c A ln=1.35×1×3×7.488×10000/1000=303.264kN≥F1=16.408kN满足要求!。
梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑结构荷载规范》GB 50009-20122、《混凝土结构设计规范》GB50010-20103、《钢结构设计规范》GB 50017-20034、《危险性较大的分部分项工程安全管理规范》DGJ08-2077-20105、《钢管扣件式模板垂直支撑系统安全技术规程》DG/TJ08-16-2011一、工程概况二、模板支撑体系设计混凝土梁支撑方式梁两侧有板,梁底次楞平行梁跨方向立杆纵向间距l a(mm) 900 立杆横向间距l b(mm) 900 模板支架步距h(mm) 1500 楼板立杆纵向间距l a'(mm) 900 楼板立杆横向间距l b'(mm) 900 梁左侧立杆距梁中心线距离(mm) 450 梁底增加承重立杆根数 2梁底增加立杆的布置方式按梁两侧立杆间距均分梁底增加立杆依次距梁左侧立杆的距离(mm)300,600梁底立杆支撑方式可调托座2 每纵距内附加梁底支撑主楞根数 1设计简图如下:模板设计立面图模板设计平面图三、荷载设计四、模板验算取1.0m单位宽度计算。
计算简图如下:W=bh2/6=1000×152/6=37500mm3,I=bh3/12=1000×153/12=281250mm4q=1.2Σq Gk+1.4Σq Qk=1.2×[0.3+(25+1.5)×1.2]×1.0+1.4×(1+2)×1.0=42.72kN/m q`=Σq Gk+Σq Qk=[0.3+(25+1.5)×1.2]×1.0+(1+2)×1.0=35.1kN/m1、抗弯验算M max=0.1ql2=0.1×42.72×0.1162=0.057kN·mσmax=M max/W=0.057×106/37500=1.533N/mm2≤[f]=17N/mm2符合要求!2、抗剪验算Q max=0.6ql=0.6×42.72×0.116=2.973kNτmax=3Q max/(2bh)=3×2.973×103/(2×1000×15)=0.297N/mm2≤[τ]=1.4N/mm2 符合要求!3、挠度验算νmax=0.677q`l4/(100EI)=0.677×35.1×1164/(100×5000×281250)=0.031mmνmax=0.031mm≤[ν]=min[L/150,10]=min[116/150,10]=0.773mm符合要求!4、支座反力R1=R4=0.4ql=1.982kN,R2=R3=1.1ql=5.451kNR`1=R`4=0.4q`l=1.629kN,R`2=R`3=1.1q`l=4.479kN五、次楞验算次楞自重荷载:q1=1.2Q=1.2×0.01=0.012kN/m梁左侧楼板传递给次楞荷载:q2=1.2ΣN Gk+1.4ΣN Qk=[1.2×(0.3+(25+1.1)×0.12)+1.4×(1+2)]×(0.45-0.35/2)/2=1.144kN/m梁右侧楼板传递给次楞荷载:q3=1.2ΣN Gk+1.4ΣN Qk=[1.2×(0.3+(25+1.1)×0.12)+1.4×(1+2)]×(0.9-0.45-0.35/2)/2=1.144kN/m梁左侧模板传递给次楞的荷载:q4=1.2ΣN Gk=1.2×0.5×(1.2-0.12)=0.648kN/m梁右侧模板传递给次楞的荷载:q5=1.2ΣN Gk=1.2×0.5×(1.2-0.12)=0.648kN/mq=max[1.982/1.0+0.012+1.144+0.648, 5.451/1.0+0.012,1.982/1.0+0.012+1.144+0.648]=5.463kN/mq`=max[1.629/1.0+0.01+0.884+0.54, 4.479/1.0+0.01,1.629/1.0+0.01+0.884+0.54]=4.489kN/m计算简图如下:1、强度验算M max=0.1ql2=0.1×5.463×0.452=0.111kN·mσmax=M max/W=0.111×106/42667=2.593N/mm2≤[f]=15.444N/mm2符合要求!2、抗剪验算Q max=0.6ql=0.6×5.463×0.45=1.475kNτmax=3Q max/(2bh0)=3×1.475×1000/(2×40×80)=0.691N/mm2τmax=0.691N/mm2≤[τ]=1.782N/mm2符合要求!3、挠度验算νmax=0.677q`l4/(100EI)=0.677×4.489×4504/(100×9350×1706670)=0.078mm νmax=0.078mm≤[ν]=min[L/150,10]=min[450/150,10]=3mm符合要求!4、支座反力计算梁底次楞依次最大支座反力为:R1=1.1×(1.982+0.012+1.144+0.648)×0.45=1.874kNR2=1.1×(5.451+0.012)×0.45=2.704kNR3=1.1×(5.451+0.012)×0.45=2.704kNR4=1.1×(1.982+0.012+1.144+0.648)×0.45=1.874kN R`1=1.1×(1.629+0.01+0.884+0.54)×0.45=1.516kNR`2=1.1×(4.479+0.01)×0.45=2.222kNR`3=1.1×(4.479+0.01)×0.45=2.222kNR`4=1.1×(1.629+0.01+0.884+0.54)×0.45=1.516kN 六、主楞验算主楞自重荷载:q1=1.2q=1.2×0.03=0.036kN/m计算简图如下:1、强度验算主楞弯矩图(kN·m)M max=0.129kN·mσmax=M max/W=0.129×106/4120=31.202N/mm2≤[f]=205N/mm2 符合要求!2、抗剪验算主楞剪力图(kN)Q max=2.71kNτmax=2Q max/A=2×2.71×1000/384=14.113N/mm2τmax=14.113N/mm2≤[τ]=125N/mm2符合要求!3、挠度验算主楞变形图(mm)νmax=0.044mm≤[ν]=min[L/150,10]=min[300/150,10]=2mm符合要求!4、支座反力支座反力依次为R1=-0.239kN,R2=4.834kN,R3=4.834kN,R4=-0.239kN支座反力依次为R`1=-0.198kN,R`2=3.95kN,R`3=3.95kN,R`4=-0.198kN七、2号主楞验算2号主楞材质类型钢管2号主楞截面类型(mm) Φ48×2.72号主楞计算截面类型(mm) Φ48×2.72号主楞材料自重(kN/m) 0.032号主楞截面面积(mm2) 384 2号主楞抗弯强度设计值[f](N/mm2) 2052号主楞抗剪强度设计值[τ](N/mm2) 125 2号主楞截面抵抗矩W(cm3) 4.122号主楞截面惯性矩I(cm4) 9.89 2号主楞弹性模量E(N/mm2) 206000主楞受力不均匀系数0.6 验算方式二等跨连续梁因可调托座内主楞根数为2,验算时取主楞受力不均匀系数=0.6。
消防连廊梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工模板安全技术规范》JGJ162-20083、《混凝土结构设计规范》GB 50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计规范》GB 50017-2003一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 12 面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5 面板弹性模量E(N/mm2) 5400W=bh2/6=1000×12×12/6=24000mm3,I=bh3/12=1000×12×12×12/12=144000mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q1k]×b=1×max[1.2×(0.1+(24+1.5)×0.9)+1.4×3,1.35×(0.1+(24+1.5)×0.9)+1.4×0.7×3]×1=34.057kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.9)]×1=23.05kN/m计算简图如下:1、强度验算M max=0.125q1L2=0.125×34.057×0.22=0.17kN·mσ=M max/W=0.17×106/24000=7.095N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=5q2L4/(384EI)=5×23.05×2004/(384×5400×144000)=0.618mm≤[ν]=L/250=200/250=0.8mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R2=0.5q1L=0.5×34.057×0.2=3.406kN标准值(正常使用极限状态)R1'=R2'=0.5q2L=0.5×23.05×0.2=2.305kN五、小梁验算小梁类型方木小梁截面类型(mm) 40×80小梁抗弯强度设计值[f](N/mm2) 11.44 小梁抗剪强度设计值[τ](N/mm2) 1.232小梁截面抵抗矩W(cm3) 42.667 小梁弹性模量E(N/mm2) 7040梁底面板传递给左边小梁线荷载:q1左=R1/b=3.406/1=3.406kN/m梁底面板传递给右边小梁线荷载:q1右=R2/b=3.406/1=3.406kN/m小梁自重:q2=1×1.35×(0.3-0.1)×0.2/2 =0.027kN/m梁左侧模板传递给左边小梁荷载q3左=1×1.35×0.5×0.9=0.608kN/m梁右侧模板传递给右边小梁荷载q3右=1×1.35×0.5×(0.9-0.12)=0.527kN/m梁右侧楼板传递给右边小梁荷载q4右=1×Max[1.2×(0.5+(24+1.1)×0.12)+1.4×3,1.35×(0.5+(24+1.1)×0.12)+1.4×0.7×3]×((0.625-0.375)-0.2/2)/2×1=0.631kN/m左侧小梁荷载q左=q1左+q2+q3左=3.406+0.027+0.608=4.04kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右=3.406+0.027+0.527+0.631=4.59kN/m小梁最大荷载q=Max[q左,q右]=Max[4.04,4.59]=4.59kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=2.305/1=2.305kN/m梁底面板传递给右边小梁线荷载:q1右'=R2'/b=2.305/1=2.305kN/m小梁自重:q2'=1×(0.3-0.1)×0.2/2 =0.02kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×0.9=0.45kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(0.9-0.12)=0.39kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.12)]×((0.625-0.375)-0.2/2)/2×1=0.263kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'=2.305+0.02+0.45=2.775kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =2.305+0.02+0.39+0.263=2.978kN/m小梁最大荷载q'=Max[q左',q右']=Max[2.775,2.978]=2.978kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×4.59×0.6252,0.5×4.59×0.22]=0.224kN·mσ=M max/W=0.224×106/42667=5.253N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×4.59×0.625,4.59×0.2]=1.434kNτmax=3V max/(2bh0)=3×1.434×1000/(2×40×80)=0.672N/mm2≤[τ]=1.232N/mm2 满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×2.978×6254/(384×7040×170.667×104)=0.492mm≤[ν]=l1/250=625/250=2.5mmν2=q'l24/(8EI)=2.978×2004/(8×7040×170.667×104)=0.05mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算承载能力极限状态R max=max[qL1,0.5qL1+qL2]=max[4.59×0.625,0.5×4.59×0.625+4.59×0.2]=2.869kN 同理可得:梁底支撑小梁所受最大支座反力依次为R1=2.525kN,R2=2.869kN正常使用极限状态R max'=max[q'L1,0.5q'L1+q'L2]=max[2.978×0.625,0.5×2.978×0.625+2.978×0.2]=1.861kN 同理可得:梁底支撑小梁所受最大支座反力依次为R1'=1.734kN,R2'=1.861kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48×2.8主梁计算截面类型(mm) Φ48×2.8主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.191、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.151×106/4250=35.63N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图(kN)V max=2.327kNτmax=2V max/A=2×2.327×1000/398=11.694N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算主梁变形图(mm)νmax=0.023mm≤[ν]=L/250=375/250=1.5mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.27kN,R2=4.582kN,R3=0.542kN正常使用极限状态支座反力依次为R1'=0.191kN,R2'=3.067kN,R3'=0.337kN七、2号主梁验算主梁类型钢管主梁截面类型(mm) Φ48×2.8主梁计算截面类型(mm) Φ48×2.8主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19 主梁计算方式三等跨连续梁可调托座内主梁根数 2主梁受力不均匀系数0.6P=max[R2]×0.6=Max[4.582]×0.6=2.749kN,P'=max[R2']×0.6=Max[3.067]×0.6=1.84kN1、抗弯验算2号主梁弯矩图(kN·m)σ=M max/W=0.601×106/4250=141.496N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算2号主梁剪力图(kN)V max=1.787kNτmax=2V max/A=2×1.787×1000/398=8.979N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算2号主梁变形图(mm)νmax=1.979mm≤[ν]=L/250=1250/250=5mm满足要求!4、支座反力计算极限承载能力状态支座反力依次为R1=3.711kN,R2=5.91kN,R3=5.91kN,R4=3.711kN立杆所受主梁支座反力依次为P2=5.91/0.6=9.851kN八、纵向水平钢管验算钢管截面类型(mm) Φ48×2.8钢管计算截面类型(mm) Φ48×2.8钢管截面面积A(mm2) 398 钢管截面回转半径i(mm) 16钢管弹性模量E(N/mm2) 206000 钢管截面惯性矩I(cm4) 10.19 钢管截面抵抗矩W(cm3) 4.25 钢管抗弯强度设计值[f](N/mm2) 205钢管抗剪强度设计值[τ](N/mm2) 1251313计算简图如下:1、抗弯验算纵向水平钢管弯矩图(kN·m)σ=M max/W=0.119×106/4250=27.898N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算纵向水平钢管剪力图(kN)V max=0.352kNτmax=2V max/A=2×0.352×1000/398=1.77N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算纵向水平钢管变形图(mm)νmax=0.362mm≤[ν]=L/250=1250/250=5mm满足要求!4、支座反力计算支座反力依次为R1=0.732kN,R2=1.165kN,R3=1.165kN,R4=0.732kN同理可得:两侧立杆所受支座反力依次为R1=0.581kN,R3=1.165kN九、可调托座验算荷载传递至立杆方式可调托座2 可调托座承载力容许值[N](kN) 30扣件抗滑移折减系数k c 1两侧立杆最大受力N=max[R1,R3]=max[0.581,1.165]=1.165kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2]=9.851kN≤[N]=30kN满足要求!十、立杆验算l0=h=1500mmλ=l0/i=1500/16=93.75≤[λ]=210长细比满足要求!查表得:φ=0.6412、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1×0.6×1.4×(1×0.075×1.25×1.52/10)=0.018kN·m3、稳定性计算R1=0.581kN,P2=9.851kN,R3=1.165kN梁两侧立杆承受楼板荷载:右侧楼板传递给梁右侧立杆荷载:N边=1×max[1.2×(0.5+(24+1.1)×0.12)+1.4×3,1.35×(0.5+(24+1.1)×0.12)+0.7×1.4×3]×(0.6+0.625-0.375-0.2/2)/2×1.25=3.944kNN d=max[R1,P2,R3+N边]+1×1.35×0.15×(3-0.9)=max[0.581,9.851,1.165+3.944]+0.425=10.276kNf d=N d/(φA)+M wd/W=10275.913/(0.641×398)+0.018×106/4250=44.514N/mm2≤[f]=205N/mm2满足要求!十一、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=3/12=0.25≤3满足要求!十二、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=1.25×1.583=1.979kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=1.25×1.5×0.79=1.481kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×32×1.979+3×1.481=13.348kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j=B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=122×1.25×[0.15×3/(1.25×0.6)+0.5]+2×1×12/2=210k N.m≥3γ0M ok =3×1×13.348=40.044kN.M满足要求!。
L11(2)梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《混凝土结构设计规范》GB 50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计标准》GB 50017-2017一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 15面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4φc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×0.6)+1.4×2,1.35×(0.1+(24+1.5)×0.6)+1.4×0.7×2]×1=20.475kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×0.6]×1=18.711kN/mq1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.6)]×1=15.4kN/m计算简图如下:1、强度验算M max=0.125q1L2=0.125×20.475×0.152=0.058kN·mσ=M max/W=0.058×106/37500=1.536N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.521q2L4/(100EI)=0.521×15.4×1504/(100×5400×281250)=0.027mm≤[ν]=L/250=150/250=0.6mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R3=0.375q1静L+0.437q1活L=0.375×18.711×0.15+0.437×1.764×0.15=1.168kN R2=1.25q1L=1.25×20.475×0.15=3.839kN标准值(正常使用极限状态)R1'=R3'=0.375q2L=0.375×15.4×0.15=0.866kNR2'=1.25q2L=1.25×15.4×0.15=2.888kN五、小梁验算梁底面板传递给左边小梁线荷载:q1左=R1/b=1.168/1=1.168kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2]/b = Max[3.839]/1= 3.839kN/m梁底面板传递给右边小梁线荷载:q1右=R3/b=1.168/1=1.168kN/m小梁自重:q2=0.9×1.35×(0.3-0.1)×0.3/2 =0.036kN/m梁左侧模板传递给左边小梁荷载q3左=0.9×1.35×0.5×(0.6-0.14)=0.279kN/m梁右侧模板传递给右边小梁荷载q3右=0.9×1.35×0.5×(0.6-0.14)=0.279kN/m梁左侧楼板传递给左边小梁荷载q4左=0.9×Max[1.2×(0.5+(24+1.1)×0.14)+1.4×2,1.35×(0.5+(24+1.1)×0.14)+1.4×0.7×2]×(0.3-0.3/2)/2×1=0.514kN/m梁右侧楼板传递给右边小梁荷载q4右=0.9×Max[1.2×(0.5+(24+1.1)×0.14)+1.4×2,1.35×(0.5+(24+1.1)×0.14)+1.4×0.7×2]×((0.6-0.3)-0.3/2)/2×1=0.514kN/m左侧小梁荷载q左=q1左+q2+q3左+q4左=1.168+0.036+0.279+0.514=1.998kN/m中间小梁荷载q中= q1中+ q2=3.839+0.036=3.876kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右=1.168+0.036+0.279+0.514=1.998kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[1.998,3.876,1.998]=3.876kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=0.866/1=0.866kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2']/b = Max[2.888]/1= 2.888kN/m梁底面板传递给右边小梁线荷载:q1右'=R3'/b=0.866/1=0.866kN/m小梁自重:q2'=1×(0.3-0.1)×0.3/2 =0.03kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(0.6-0.14)=0.23kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(0.6-0.14)=0.23kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(24+1.1)×0.14)]×(0.3-0.3/2)/2×1=0.301kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.14)]×((0.6-0.3)-0.3/2)/2×1=0.301kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=0.866+0.03+0.23+0.301=1.427kN/m中间小梁荷载q中'= q1中'+ q2'=2.888+0.03=2.917kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =0.866+0.03+0.23+0.301=1.427kN/m小梁最大荷载q'=Max[q左',q中',q右']=Max[1.427,2.917,1.427]=2.917kN/m为简化计算,按二等跨连续梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×3.876×0.82,0.5×3.876×0.22]=0.31kN·mσ=M max/W=0.31×106/53333=5.814N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.625ql1,ql2]=max[0.625×3.876×0.8,3.876×0.2]=1.938kNτmax=3V max/(2bh0)=3×1.938×1000/(2×50×80)=0.727N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=0.521q'l14/(100EI)=0.521×2.917×8004/(100×7500×213.333×104)=0.389mm≤[ν]=l1/250=800/250=3.2mmν2=q'l24/(8EI)=2.917×2004/(8×7500×213.333×104)=0.036mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算承载能力极限状态R max=max[1.25qL1,0.375qL1+qL2]=max[1.25×3.876×0.8,0.375×3.876×0.8+3.876×0.2]= 3.876kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=1.998kN,R2=3.876kN,R3=1.998kN 正常使用极限状态R max'=max[1.25q'L1,0.375q'L1+q'L2]=max[1.25×2.917×0.8,0.375×2.917×0.8+2.917×0.2] =2.917kN同理可得:梁底支撑小梁所受最大支座反力依次为R1'=1.427kN,R2'=2.917kN,R3'=1.427kN 六、主梁验算主梁计算截面类型(mm) Ф48×3.2 主梁抗弯强度设计值[f](N/mm2) 205 主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.73 主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 11.361、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.881×106/4730=186.279N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图(kN)V max=3.936kNτmax=2V max/A=2×3.936×1000/450=17.493N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.938mm≤[ν]=L/250=600/250=2.4mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=3.936kN,R2=3.936kN七、扣件抗滑移验算荷载传递至立杆方式双扣件扣件抗滑移折减系数k c0.8512c c满足要求!八、立杆验算立杆钢管截面类型(mm) Φ48×3.5 立杆钢管计算截面类型(mm) Ф48×3.2 钢材等级Q235 立杆截面面积A(mm2) 450回转半径i(mm) 15.9 立杆截面抵抗矩W(cm3) 4.73l0=h=1500mmλ=l0/i=1500/15.9=94.34≤[λ]=150长细比满足要求!查表得,φ=0.6342、风荷载计算M w=0.9×φc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.589×0.8×1.52/10=0.12kN·m3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2008,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×0.6)+1.4×0.9×2]×1=18.9kN/m2)小梁验算q1=max{1.084+0.9×1.2×[(0.3-0.1)×0.3/2+0.5×(0.6-0.14)]+0.9×[1.2×(0.5+(24+1.1)×0.14)+1. 4×0.9×1]×max[0.3-0.3/2,(0.6-0.3)-0.3/2]/2×1,3.544+0.9×1.2×(0.3-0.1)×0.3/2}=3.576kN/m同上四~六计算过程,可得:R1=3.563kN,R2=3.563kN立杆最大受力N w=max[R1+N边1,R2+N边2]+0.9×1.2×0.15×(5.1-0.6)+M w/l b=max[3.563+0.9×[1.2×(0.5+(24+1.1)×0.14)+1.4×0.9×1]×(0.8+0.3-0.3/2)/2×0.8,3.563+0.9×[1.2×(0.5+(24+1.1)×0.14)+1.4×0.9×1]×(0.8+0.6-0.3-0.3/2)/2×0.8]+0.729+0.1 2/0.6=6.571kNf=N/(φA)+M w/W=6570.643/(0.634×450)+0.12×106/4730=48.401N/mm2≤[f]=205N/mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011 第6.9.7:支架高宽比不应大于3H/B=5.1/650=0.008≤3满足要求,不需要进行抗倾覆验算!十、立杆地基基础计算f ak 300kPa满足要求!。
梁模板300800(扣件式)计算书
梁模板(扣件式)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《混凝土结构设计规范》GB50010-20104、《建筑结构荷载规范》GB 50009-20125、《钢结构设计规范》GB 50017-2003一、工程属性新浇混凝土梁名称KL13 新浇混凝土梁计算跨度(m) 3.5 混凝土梁截面尺寸(mm×mm) 300*800 新浇混凝土结构层高(m) 6.1 梁侧楼板厚度(mm) 110二、荷载设计模板及其支架自重标准值G1k(kN/m2) 面板0.1 面板及小梁0.3 模板面板0.5 模板及其支架0.75新浇筑混凝土自重标准值G2k(kN/m3)24混凝土梁钢筋自重标准值G3k(kN/m3)1.5 混凝土板钢筋自重标准值G3k(kN/m3) 1.1 当计算支架立柱及其他支承结构构件时Q1k(kN/m2)1 对水平面模板取值Q2k(kN/m2) 2风荷载标准值ωk(kN/m2) 基本风压ω0(kN/m2)0.3非自定义:0.16 风压高度变化系数μz0.65风荷载体型系数μs0.8三、模板体系设计新浇混凝土梁支撑方式梁两侧有板,梁板立柱共用(A) 梁跨度方向立柱间距l a(mm) 900梁两侧立柱间距l b(mm) 1000步距h(mm) 1800新浇混凝土楼板立柱间距l 'a(mm)、l'b(mm) 900、900混凝土梁居梁两侧立柱中的位置居中梁左侧立柱距梁中心线距离(mm) 500梁底增加立柱根数 2梁底增加立柱布置方式按梁两侧立柱间距均分梁底增加立柱依次距梁左侧立柱距离(mm) 500梁底支撑小梁根数 2每纵距内附加梁底支撑主梁根数0梁底支撑小梁最大悬挑长度(mm) 100结构表面的要求结构表面隐蔽模板及支架计算依据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011 设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板 面板厚度(mm)15 面板抗弯强度设计值[f](N/mm 2)22面板弹性模量E(N/mm 2)10000取单位宽度1000mm ,按三等跨连续梁计算,计算简图如下:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4q1=0.9max[1.2(G1k+ (G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4×0.7Q2k]×b=0.9max[1.2×(0.1+(24+1.5)×1.4)+1.4×2,1.35×(0.1+(24+1.5)×1.4)+1.4×0.7×2]×1=45.261kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×1.4]×1=43.497kN/mq1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=(G1k+ (G2k+G3k)×h)×b=[0.1+(24+1.5)×1.4]×1=35.8kN/m1、强度验算M max=0.1q1静L2+0.117q1活L2=0.1×43.497×0.2672+0.117×1.764×0.2672=0.324kN·mσ=M max/W=0.324×106/37500=8.64N/mm2≤[f]=22N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×35.8×266.6674/(100×10000×281250)=0.436mm≤[ν]=l/250=266.667/250=1.067mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R4=0.4 q1静l +0.45 q1活l=0.4×43.497×0.267+0.45×1.764×0.267=4.851kNR 2=R 3=1.1 q 1静l +1.2 q 1活l=1.1×43.497×0.267+1.2×1.764×0.267=13.324kN 标准值(正常使用极限状态)R 1'=R 4'=0.4 q 2l=0.4×35.8×0.267=3.819kN R 2'=R 3'=1.1 q 2l=1.1×35.8×0.267=10.501kN五、小梁验算小梁类型方木 小梁材料规格(mm)45×90 小梁抗弯强度设计值[f](N/mm 2) 13.07 小梁抗剪强度设计值[τ](N/mm 2) 1.43 小梁弹性模量E(N/mm 2) 8415 小梁截面抵抗矩W(cm 3)60.75小梁截面惯性矩I(cm 4)273.38为简化计算,按四等跨连续梁和悬臂梁分别计算,如下图:q 1=max{4.851+0.9×1.35×[(0.3-0.1)×0.8/3+0.5×(1.4-0.12)]+0.9max[1.2×(0.5+(24+1.1)×0.12)+1.4×2,1.35×(0.5+(24+1.1)×0.12)+1.4×0.7×2]×max[0.7-0.8/2,(1.4-0.7)-0.8/2]/2×1,13.324+0.9×1.35×(0.3-0.1)×0.8/3}=13.388kN/mq2=max[3.819+(0.3-0.1)×0.8/3+0.5×(1.4-0.12)+(0.5+(24+1.1)×0.12)×max[0.7-0.8/2,(1.4-0.7)-0.8/2]/2×1,10.501+(0.3-0.1)×0.8/3]=10.555kN/m1、抗弯验算M max=max[0.107q1l12,0.5q1l22]=max[0.107×13.388×0.452,0.5×13.388×0.12]=0.29kN·mσ=M max/W=0.29×106/60750=4.775N/mm2≤[f]=13.07N/mm2满足要求!2、抗剪验算V max=max[0.607q1l1,q1l2]=max[0.607×13.388×0.45,13.388×0.1]=3.657kN τmax=3V max/(2bh0)=3×3.657×1000/(2×45×90)=1.354N/mm2≤[τ]=1.43N/mm2满足要求!3、挠度验算ν1=0.632q2l14/(100EI)=0.632×10.555×4504/(100×8415×2733800)=0.119mm≤[ν]=l/250=450/250=1.8mmν2=q2l24/(8EI)=10.555×1004/(8×8415×2733800)=0.006mm≤[ν]=l/250=100/250=0.4mm满足要求!4、支座反力计算梁头处(即梁底支撑小梁悬挑段根部)承载能力极限状态R max=max[1.143q1l1,0.393q1l1+q1l2]=max[1.143×13.388×0.45,0.393×13.388×0.45+13.388×0.1]=6.886kN同理可得,梁底支撑小梁所受最大支座反力依次为R1=R4=3.416kN,R2=R3=6.886kN正常使用极限状态R'max=max[1.143q2l1,0.393q2l1+q2l2]=max[1.143×10.555×0.45,0.393×10.555×0.45+10.555×0.1]=5.429kN同理可得,梁底支撑小梁所受最大支座反力依次为R'1=R'4=2.884kN ,R'2=R'3=5.429kN六、主梁验算主梁类型钢管 主梁材料规格(mm) Ф48×3 可调托座内主梁根数1 主梁弹性模量E(N/mm 2) 206000 主梁抗弯强度设计值[f](N/mm 2) 205 主梁抗剪强度设计值[τ](N/mm 2) 125 主梁截面惯性矩I(cm 4)10.78主梁截面抵抗矩W(cm 3)4.49主梁自重忽略不计,计算简图如下:1、抗弯验算主梁弯矩图(kN·m)σ=M max /W =0.444×106/4490=98.916N/mm 2≤[f]=205N/mm 2 满足要求! 2、抗剪验算主梁剪力图(kN)V max=6.886kNτmax=2V max/A=2×6.886×1000/424=32.481N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.185mm≤[ν]=l/250=467/250=1.868mm满足要求!4、扣件抗滑计算R=max[R1,R4]=0.272kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!同理可知,右侧立柱扣件受力R=0.272kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!七、立柱验算剪刀撑设置加强型 立杆顶部步距h d (mm) 1500 立杆伸出顶层水平杆中心线至支撑点的长度a(mm)200顶部立杆计算长度系数μ11.386非顶部立杆计算长度系数μ2 1.755 钢管类型 Ф48×3 立柱截面面积A(mm 2) 424 回转半径i(mm)15.9 立柱截面抵抗矩W(cm 3) 4.49 抗压强度设计值f(N/mm 2)205立杆自重q(kN/m)0.15长细比验算顶部立杆段:l 01=kμ1(h d +2a)=1×1.386×(1500+2×200)=2633.4mm 非顶部立杆段:l 02=kμ2h =1×1.755×1500=2632.5mm λ=l 0/i=2633.4/15.9=165.623≤[λ]=210 长细比满足要求! 1、风荷载计算M w =0.9×1.4×ωk ×l a ×h 2/10=0.9×1.4×0.16×0.45×1.52/10=0.02kN·m 2、稳定性计算根据《建筑施工模板安全技术规范》公式5.2.5-14,荷载设计值q 1有所不同: 1)面板验算q 1=[1.2×(0.1+(24+1.5)×1.4)+0.9×1.4×2]×1=45.48kN/m 2)小梁验算 q 1=max{4.396+(0.3-0.1)×0.8/3+[1.2×(0.5+(24+1.1)×0.12)+0.9×1.4×1]×max[0.7-0.8/2,(1.4-0.7)-0.8/2]/2×1,12.067+(0.3-0.1)×0.8/3}=12.121kN/m 同上四~六计算过程,可得:R 1=0.271kN ,R 2=9.145kN ,R 3=9.145kN ,R 4=0.271kN顶部立杆段:l 01=kμ1(h d +2a)=1.217×1.386×(1500+2×200)=3204.848mm λ1=l 01/i =3204.848/15.9=201.563,查表得,υ1=0.179 立柱最大受力N w =max[R 1+N 边1,R 2,R 3,R 4+N 边2]+M w /l b =max[0.271+[1.2×(0.5+(24+1.1)×0.12)+0.9×1.4×1]×(0.9+0.7-0.8/2)/2×0.9,9.145,9.145,0.271+[1.2×(0.5+(24+1.1)×0.12)+0.9×1.4×1]×(0.9+1.4-0.7-0.8/2)/2×0.9]+0.02/1.4=9.174kNf=N/(υA)+M w/W=9173.749/(0.179×424)+0.02×106/4490=125.419N/mm2≤[f]=205N/mm2满足要求!非顶部立杆段:l02=kμ2h =1.217×1.755×1500=3203.752mmλ2=l02/i=3203.752/15.9=201.494,查表得,υ2=0.179立柱最大受力N w=max[R1+N边1,R2,R3,R4+N边2]+0.15×(11.4-1.4)+M w/l b=max[0.271+[1.2×(0.75+(24+1.1)×0.12)+0.9×1.4×1]×(0.9+0.7-0.8/2)/2×0.9,9.145,9.145,0.271+[1.2×(0.75+(24+1.1)×0.12)+0.9×1.4×1]×(0.9+1.4-0.7-0.8/2)/2×0.9]+1.5+0.02/1.4=10.659kNf=N/(υA)+M w/W=10659.169/(0.179×424)+0.02×106/4490=144.991N/mm2≤[f]=205N/mm2满足要求!八、可调托座验算荷载传递至立杆方式可调托座2 可调托座承载力容许值[N](kN) 30 由"主梁验算"一节计算可知可调托座最大受力N=max[R2,R3]×1=10.03kN≤[N]=30kN满足要求!。
500x1400梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《混凝土结构设计规范》GB 50010-20103、《建筑结构荷载规范》GB 50009-20124、《钢结构设计规范》GB 50017-2003一、工程属性二、荷载设计三、模板体系设计设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 15面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400取单位宽度b=1000mm,按四等跨连续梁计算:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4 q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×1.4)+1.4×2,1.35×(0.1+(24+1.5)×1.4)+1.4×0.7×2]×1=45.26 1kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×1.4]×1=43.497kN/m q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1.4)]×1=35.8kN/m计算简图如下:1、强度验算M max=0.107q1静L2+0.121q1活L2=0.107×43.497×0.12+0.121×1.764×0.12=0.049kN·m σ=M max/W=0.049×106/37500=1.298N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.632q2L4/(100EI)=0.632×35.8×1004/(100×5400×281250)=0.015mm≤[ν]=L/400=100/400=0.25mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R5=0.393q1静L+0.446q1活L=0.393×43.497×0.1+0.446×1.764×0.1=1.788kN R2=R4=1.143q1静L+1.223q1活L=1.143×43.497×0.1+1.223×1.764×0.1=5.187kNR3=0.928q1静L+1.142q1活L=0.928×43.497×0.1+1.142×1.764×0.1=4.238kN标准值(正常使用极限状态)R1'=R5'=0.393q2L=0.393×35.8×0.1=1.407kNR2'=R4'=1.143q2L=1.143×35.8×0.1=4.092kNR3'=0.928q2L=0.928×35.8×0.1=3.322kN五、小梁验算承载能力极限状态:梁底面板传递给左边小梁线荷载:q1左=R1/b=1.788/1=1.788kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3,R4]/b=Max[5.187,4.238,5.18 7]/1=5.187kN/m梁底面板传递给右边小梁线荷载:q1右=R5/b=1.788/1=1.788kN/m小梁自重:q2=0.9×1.35×(0.3-0.1)×0.5/5 =0.024kN/m梁左侧模板传递给左边小梁荷载q3左=0.9×1.35×0.5×(1.4-0.2)=0.729kN/m梁右侧模板传递给右边小梁荷载q3右=0.9×1.35×0.5×(1.4-0.2)=0.729kN/m梁左侧楼板传递给左边小梁荷载q4左=0.9×Max[1.2×(0.5+(24+1.1)×0.2)+1.4×2,1.35×(0.5+(24+1.1)×0.2)+1.4×0.7×2]×(0.55-0.5/2)/2×1=1.272kN/m梁右侧楼板传递给右边小梁荷载q4右=0.9×Max[1.2×(0.5+(24+1.1)×0.2)+1.4×2,1.35×(0.5+(24+1.1)×0.2)+1.4×0.7×2]×((1.1-0.55)-0.5/2)/2×1=1.272kN/m左侧小梁荷载q左=q1左+q2+q3左+q4左 =1.788+0.024+0.729+1.272=3.814kN/m中间小梁荷载q中= q1中+ q2=5.187+0.024=5.212kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右 =1.788+0.024+0.729+1.272=3.814kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[3.814,5.212,3.814]=5.212kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=1.407/1=1.407kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3',R4']/b=Max[4.092,3.322,4.0 92]/1=4.092kN/m梁底面板传递给右边小梁线荷载:q1右'=R5'/b=1.407/1=1.407kN/m小梁自重:q2'=1×(0.3-0.1)×0.5/5 =0.02kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(1.4-0.2)=0.6kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(1.4-0.2)=0.6kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(24+1.1)×0.2)]×(0.55-0.5/2)/2×1=0.82 8kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.2)]×((1.1-0.55)-0.5/2)/2×1 =0.828kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=1.407+0.02+0.6+0.828=2.855kN/m中间小梁荷载q中'= q1中'+ q2'=4.092+0.02=4.112kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =1.407+0.02+0.6+0.828=2.855kN/m小梁最大荷载q'=Max[q左',q中',q右']=Max[2.855,4.112,2.855]=4.112kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×5.212×0.82,0.5×5.212×0.22]=0.417kN·mσ=M max/W=0.417×106/54000=7.721N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×5.212×0.8,5.212×0.2]=2.085kNτmax=3V max/(2bh0)=3×2.085×1000/(2×40×90)=0.869N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×4.112×8004/(384×7040×243×104)=1.282mm≤[ν]=l1/400=800/400=2mmν2=q'l24/(8EI)=4.112×2004/(8×7040×243×104)=0.048mm≤[ν]=2l2/400=2×200/400=1mm满足要求!4、支座反力计算承载能力极限状态R max=[qL1,0.5qL1+qL2]=max[5.212×0.8,0.5×5.212×0.8+5.212×0.2]=4.17kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=3.051kN,R2=4.17kN,R3=3.41kN,R4=3.41k N,R5=4.17kN,R6=3.051kN正常使用极限状态R max'=[q'L1,0.5q'L1+q'L2]=max[4.112×0.8,0.5×4.112×0.8+4.112×0.2]=3.29kN同理可得:梁底支撑小梁所受最大支座反力依次为R1'=2.284kN,R2'=3.29kN,R3'=2.674kN,R4'=2.6 74kN,R5'=3.29kN,R6'=2.284kN六、主梁验算1、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.309×106/4490=68.779N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算主梁剪力图(kN)V max=7.58kNτmax=2V max/A=2×7.58×1000/424=35.755N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.12mm≤[ν]=L/400=367/400=0.917mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.283kN,R2=10.914kN,R3=10.914kN,R4=0.283kN七、可调托座验算荷载传递至立柱方式可调托座可调托座承载力容许值[N](kN) 30扣件抗滑移折减系数k c 11、扣件抗滑移验算两侧立柱最大受力N=max[R1,R4]=max[0.283,0.283]=0.283kN≤1×8=8kN单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[R2,R3]=10.914kN≤[N]=30kN满足要求!八、立柱验算1、长细比验算l0=h=1500mmλ=l0/i=1500/15.9=94.34≤[λ]=150长细比满足要求!查表得,φ=0.6342、风荷载计算M w=0.9×φc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.331×0.8×1.52/10=0.068kN·m3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2008,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×1.4)+1.4×0.9×2]×1=40.932kN/m2)小梁验算q1=max{1.621+0.9×1.2×[(0.3-0.1)×0.5/5+0.5×(1.4-0.2)]+0.9×[1.2×(0.5+(24+1.1)×0.2)+ 1.4×0.9×1]×max[0.55-0.5/2,(1.1-0.55)-0.5/2]/2×1,4.697+0.9×1.2×(0.3-0.1)×0.5/5}=4 .718kN/m同上四~六计算过程,可得:R1=0.267kN,R2=9.82kN,R3=9.82kN,R4=0.267kN立柱最大受力N w=max[R1+N边1,R2,R3,R4+N边2]+0.9×1.2×0.1×(3.7-1.4)+M w/l b=max[0.267+0.9×[1.2×(0.5+(24+1.1)×0.2)+1.4×0.9×1]×(0.8+0.55-0.5/2)/2×0.8,9.82,9. 82,0.267+0.9×[1.2×(0.5+(24+1.1)×0.2)+1.4×0.9×1]×(0.8+1.1-0.55-0.5/2)/2×0.8]+0.248+0.068/1.1=10.13kNf=N/(φA)+M w/W=10130.222/(0.634×424)+0.068×106/4490=52.829N/mm2≤[f]=205 N/mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011第6.9.7:支架高宽比不应大于3H/B=3.7/8.25=0.448≤3满足要求,不需要进行抗倾覆验算!十、立柱支承面承载力验算F1=N=10.13kN1、受冲切承载力计算根据《混凝土结构设计规范》GB50010-2010第6.5.1条规定,见下表可得:βh=1,f t=0.858N/mm2,η=1,h0=h-20=100mm,u m =2[(a+h0)+(b+h0)]=800mmF=(0.7βh f t+0.25σpc,m)ηu m h0=(0.7×1×0.858+0.25×0)×1×800×100/1000=48.048kN≥F1=1 0.13kN满足要求!2、局部受压承载力计算根据《混凝土结构设计规范》GB50010-2010第6.6.1条规定,见下表可得:f c=7.488N/mm2,βc=1,βl=(A b/A l)1/2=[(a+2b)×(b+2b)/(ab)]1/2=[(300)×(300)/(100×100)]1/2=3,A ln=ab=10000mm 2F=1.35βcβl f c A ln=1.35×1×3×7.488×10000/1000=303.264kN≥F1=10.13kN满足要求!。
梁模板(扣件式)计算书
梁模板(扣件式)计算书一、工程概况二、模板支撑体系设计模板设计立面图模板设计平面图三、荷载设计W=bh2/6=240×152/6=9000mm3,I=bh3/12=240×153/12=67500mm4q=γGΣq Gk+1.4Σq Qk=1.35×[0.3+(24+1.5)×0.7]×0.24+1.4×(1+2)×0.24=6.889kN/m1、抗弯验算M max=0.125ql2=0.125×6.889×0.22=0.034kN·mσmax=M max/W=0.034×106/9000=3.827N/mm2≤f m=15N/mm2符合要求!2、抗剪验算Q max=0.625ql=0.625×6.889×0.2=0.861kNτmax=3Q max/(2bh)=3×0.861×103/(2×240×15)=0.359N/mm2≤f v=1.4N/mm2符合要求!3、挠度验算νmax=0.521ql4/(100EI)=0.521×6.889×2004/(100×6000×67500)=0.142mmνmax=0.142mm≤[ν]=min[l/150,10]=min[200/150,10]=1.333mm符合要求!五、次楞验算1G Gk Qk=1.35×[(0.3+(24+1.5)×0.7)×0.2]+1.4×(1+2)×0.2=5.74kN/m次楞自重荷载:q2=γG Q=1.35×0.01=0.013kN/m梁左侧楼板传递给次楞荷载:F1=0kN梁右侧楼板传递给次楞荷载:F2=γGΣN Gk+1.4ΣN Qk=[1.35×(0.3+(24+1.1)×0.15)+1.4×(1+2)]×0.2×(0.8-0.4-0.24/2)/2=0.271kN梁左侧模板传递给次楞的荷载:F3=γGΣN Gk=1.35×0.5×0.2×0.7=0.094kN梁右侧模板传递给次楞的荷载:F4=γGΣN Gk=1.35×0.5×0.2×(0.7-0.15)=0.074kN 计算简图如下:1、强度验算次楞弯矩图(kN·m)M max=0.297kN·mσmax=M max/W=0.297×106/24000=12.389N/mm2≤f m=13N/mm2符合要求!2、抗剪验算次楞剪力图(kN)Q max=0.952kNτmax=3Q max/(2bh0)=3×0.952×1000/(2×40×60)=0.595N/mm2τmax=0.595N/mm2≤f v=1.3N/mm2符合要求!3、挠度验算次楞变形图(mm)νmax=2.821mm≤[ν]=min[l/150,10]=min[800/150,10]=5.333mm 符合要求!4、支座反力R1=0.876kN,R2=0.952kN六、主楞(纵向水平钢管)验算12q=γG q=1.35×0.033=0.045kN/m计算简图如下:1、强度验算主楞弯矩图(kN·m)M max=0.361kN·mσmax=M max/W=0.361×106/4490=80.313N/mm2≤f m=205N/mm2 符合要求!2、抗剪验算主楞剪力图(kN)Q max=1.897kNτmax=2Q max/A=2×1.897×1000/424=8.947N/mm2τmax=8.947N/mm2≤f v=125N/mm2符合要求!3、挠度验算主楞变形图(mm)νmax =0.463mm≤[ν]=min[l/150,10]=min[800/150,10]=5.333mm 符合要求! 4、支座反力支座反力依次为R 1=1.947kN,R 2=4.746kN,R 3=1.947kN七、横向水平钢管验算横向水平钢管起构造作用,不用计算八、扣件抗滑验算max 1.05×R max =1.05×4.746=4.983kN ,4.983kN≤0.8×12.0=9.6kN 在扭矩达到40~65N·m 的情况下,双扣件能满足要求!九、模板支架整体高宽比验算H/L b =4.5/60=0.075<5 符合要求!十、立杆验算钢管类型Ф48×3 截面面积A(mm 2) 424 截面回转半径i(mm)15.9 截面抵抗矩W(cm 3)4.49抗压、弯强度设计值[f](N/mm 2)2051、长细比验算h/l a =1500/800=1.875,h/l b =1500/800=1.875,查附录D ,得k=1.167,μ=1.325 l 0=max[kμh ,h+2a]=max[1.167×1.325×1500,1500+2×50]=2319mm λ=l 0/i=2319/15.9=146≤[λ]=210 长细比符合要求!查《规程》附录C 得 υ=0.324 2、风荷载验算1) 模板支架风荷载标准值计算l a =0.8m ,h=1.5m ,查《规程》表4.2.7得υw =0.129因风荷载沿模板支架横向作用,所以b=l a =0.8m ,b/h=0.8/1.5=0.533通过插入法求η,得η=0.96μzω0d2=0.62×0.45×0.0482=0.001,h/d=1.5/0.048=31.25通过插入法求μs1,得μs1=1.2因此μstw=υwμs1(1-ηn)/( 1-η)=0.129×1.2×(1-0.9670)/(1-0.96)=3.648μs=υwμstw=0.129×3.648=0.471ωk=0.7μzμsω0=0.7×0.62×0.471×0.45=0.092kN/m22) 整体侧向力标准值计算ωk=0.7μzμsω0=0.7×0.62×1×0.45=0.195kN/m23、稳定性验算K H=1/[1+0.005×(4.5-4)]=0.9981) 不组合风荷载时立杆从左到右受力为(N ut=γG∑N Gk+1.4∑N Qk):R1=4.37+1.35×0.15×4.5=5.282kNR2=4.746+[1.35×(0.3+(24+1.1)×0.15)×0.8+1.4×(1+2)×0.8]×(0.8/2+(0.8-0.4-0.24/2)/2) +1.35×0.15×4.5=9.842kNN ut=max[R1,R2]=max[5.282, 9.842]=9.842kN1.05N ut/(υAK H)=1.05×9.842×103/(0.324×424×0.998)=75.412N/mm2≤[f]=205N/mm2符合要求!2) 组合风荷载时立杆从左到右受力为(N ut=γG∑N Gk+0.85×1.4∑N Qk):R1=5.178kN, R2=9.436kNN ut=max[R1,R2]=max[5.178, 9.436]=9.436kNM w=0.85×1.4ωk l a h2/10=0.85×1.4×0.092×0.8×1.52/10=0.02kN·m1.05N ut/(υAK H)+M w/W=1.05×9.436×103/(0.324×424×0.998)+0.02×106/(4.49×103)=76.693N/mm2≤[f]=205N/mm 2符合要求!F k a aN1=3FH/[(m+1)L b]=3×0.055×4.5/[(34+1)×60]=0kNσ=(1.05N ut+N1)/(υAK H)=(1.05×9.436+0)×103/(0.324×424×0.998)=72.308N/mm2≤[f]=205N/mm2符合要求!。
400x900梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《建筑施工模板安全技术规范》JGJ162-20084、《混凝土结构设计规范》GB 50010-20105、《建筑结构荷载规范》GB 50009-20126、《钢结构设计标准》GB 50017-2017一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 18面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400 验算方式三等跨连续梁截面抵抗矩:W=bh2/6=400×18×18/6=21600mm3,截面惯性矩:I=bh3/12=400×18×18×18/12=194400mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4φc Q1k]×b=1×max[1.2×(0.1+(24+1.5)×0.9)+1.4×3,1.35×(0.1+(24+1.5)×0.9)+1.4×0.7×3]×0.4=13.623kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1×1.35×[0.1+(24+1.5)×0.9]×0.4=12.447kN/mq1活=γ0×1.4×0.7×Q1k×b=1×1.4×0.7×3×0.4=1.176kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.9)]×0.4=9.22kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×12.447×0.22+0.117×1.176×0.22=0.055kN·mσ=M max/W=0.055×106/21600=2.56N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×9.22×2004/(100×5400×194400)=0.095mm≤[ν]=L/250=200/250=0.8mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×12.447×0.2+1.2×1.176×0.2=3.021kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×9.22×0.2=2.028kN五、小梁验算小梁类型钢管小梁截面类型(mm) Φ48.3×3.0小梁计算截面类型(mm) Φ48×2.8 小梁抗弯强度设计值[f](N/mm2) 205小梁抗剪强度设计值[τ](N/mm2) 125 小梁截面抵抗矩W(cm3) 4.25小梁弹性模量E(N/mm2) 206000 小梁截面惯性矩I(cm4) 10.19面板传递给小梁q1=3.021/0.4=7.551kN/m小梁自重q2=1×1.35×(0.3-0.1)×0.2=0.054kN/m梁左侧楼板及侧模传递给小梁荷载F1=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35 ×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×(0.4-0.4/2)/2×0.2+1×1.35×0.5×(0.9-0.25)×0.2=0.334kN梁右侧楼板及侧模传递给小梁荷载F2=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×((0.8-0.4)-0.4/2)/2×0.2+1×1.35×0.5×(0.9-0.25)×0.2=0.334kN正常使用极限状态:面板传递给小梁q1=2.028/0.4=5.071kN/m小梁自重q2=1×(0.3-0.1)×0.2=0.04kN/m梁左侧楼板及侧模传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.25)×(0.4-0.4/2)/2×0.2+1×0.5×(0.9-0.25)×0.2=0.201kN 梁右侧楼板及侧模传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.25)×((0.8-0.4)-0.4/2)/2×0.2+1×0.5×(0.9-0.25)×0.2=0.201kN 计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.038×106/4250=8.972N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算小梁剪力图(kN)V max=1.011kNτmax=2V max/A=2×1.011×1000/398=5.083N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算小梁变形图(mm)νmax=0.005mm≤[ν]=L/250=267/250=1.068mm满足要求!4、支座反力计算承载能力极限状态R1=0.012kN,R2=1.854kN,R3=1.854kN,R4=0.012kN正常使用极限状态R'1=0.004kN,R'2=1.227kN,R'3=1.227kN,R'4=0.004kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48.3×3.0 主梁计算截面类型(mm) Φ48×2.8 主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19主梁计算方式三等跨连续梁可调托座内主梁根数 2主梁受力不均匀系数0.6由上节可知P=max[R2,R3]×0.6=1.112kN,P'=max[R2',R3']×0.6=0.736kN主梁计算简图一1、抗弯验算主梁弯矩图一(kN·m)σ=M max/W=0.289×106/4250=68N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图一(kN)V max=1.751kNτmax=2V max/A=2×1.751×1000/398=8.799N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图一(mm)跨中νmax=0.244mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.014mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=4.531kN用小梁的支座反力分别代入可得:承载能力极限状态图一立杆2:R2=4.531kN,立杆3:R3=4.531kN立杆所受主梁支座反力依次为:立杆2:P2=4.531/0.6=7.552kN,立杆3:P3=4.531/0.6=7.552kN七、纵向水平钢管验算钢管截面类型(mm) Φ48.3×3.0 钢管计算截面类型(mm) Φ48×2.8钢管截面面积A(mm2) 398 钢管截面回转半径i(mm) 16钢管弹性模量E(N/mm2) 206000 钢管截面惯性矩I(cm4) 10.19 钢管截面抵抗矩W(cm3) 4.25 钢管抗弯强度设计值[f](N/mm2) 205 钢管抗剪强度设计值[τ](N/mm2) 1251414纵向水平钢管计算简图一1、抗弯验算纵向水平钢管弯矩图一(kN·m)σ=M max/W=0.003×106/4250=0.706N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算纵向水平钢管剪力图一(kN)V max=0.019kNτmax=2V max/A=2×0.019×1000/398=0.095N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算纵向水平钢管变形图一(mm)跨中νmax=0.001mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=0.049kN用小梁两侧的支座反力分别代入可得:承载能力极限状态图一:立杆1:R1=0.049kN,立杆4:R4=0.049kN八、可调托座验算两侧立杆最大受力N=max[R1,R4]=max[0.049,0.049]=0.049kN≤0.85×8=6.8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2,P3]=7.552kN≤[N]=30kN满足要求!九、立杆验算顶部立杆段:l01=kμ1(h d+2a)=1×1.386×(750+2×200)=1594mm非顶部立杆段:l02=kμ2h =1×1.755×1500=2632mmλ=max[l01,l02]/i=2632/16=164.5≤[λ]=210长细比满足要求!顶部立杆段:l01=kμ1(h d+2a)=1.155×1.386×(750+2×200)=1841mm非顶部立杆段:l02=kμ2h =1.155×1.755×1500=3041mmλ=max[l01,l02]/i=3041/16=190.062查表得:φ=0.1992、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1×0.6 ×1.4×(1×0.031×0.8×1.52/10)=0.005kN·m3、稳定性计算R1=0.049kN,P2=7.552kN,P3=7.552kN,R4=0.049kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.4-0.4/2)/2×0.8=4.932kN右侧楼板传递给梁右侧立杆荷载:N边2=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.8-0.4-0.4/2)/2×0.8=4.932kNN d=max[R1+N边1,P2,P3,R4+N边2]+1×1.35×0.15×(3.6-0.9)=max[0.049+4.932,7.552,7.552,0.049+4.932]+0.547=8.099kNf d=N d/(φA)+M wd/W=8099.106/(0.199×398)+0.005×106/4250=103.435N/mm2≤[f]=205N/mm2满足要求!十、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=3.6/71=0.051≤3满足要求!十一、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.8×0.674=0.539kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.8×1×0.259=0.207kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×3.62×0.539+3.6×0.207=4.24kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j =B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=712×0.8×[0.15×3.6/(0.8×0.8)+0.5]+2×1×71/2=5490.075kN.m≥3γ0M ok =3×1×4.24=12.72kN.M满足要求!十二、立杆地基基础计算地基土类型素填土地基承载力特征值f ak(kPa) 140立杆垫木地基土承载力折减系数m f 1 垫板底面面积A(m2) 0.15立杆底垫板的底面平均压力p=N/(m f A)=8.099/(1×0.15)=53.994kPa≤γu f ak=1.363×140 =190.82kPa满足要求!。
600x900人防梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《建筑施工模板安全技术规范》JGJ162-20084、《混凝土结构设计规范》GB 50010-20105、《建筑结构荷载规范》GB 50009-20126、《钢结构设计标准》GB 50017-2017一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 18面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400 验算方式三等跨连续梁截面抵抗矩:W=bh2/6=600×18×18/6=32400mm3,截面惯性矩:I=bh3/12=600×18×18×18/12=291600mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4φc Q1k]×b=1×max[1.2×(0.1+(24+1.5)×0.9)+1.4×3,1.35×(0.1+(24+1.5)×0.9)+1.4×0.7×3]×0.6=20.434kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1×1.35×[0.1+(24+1.5)×0.9]×0.6=18.671kN/mq1活=γ0×1.4×0.7×Q1k×b=1×1.4×0.7×3×0.6=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.9)]×0.6=13.83kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×18.671×0.22+0.117×1.764×0.22=0.083kN·mσ=M max/W=0.083×106/32400=2.56N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×13.83×2004/(100×5400×291600)=0.095mm≤[ν]=L/250=200/250=0.8mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×18.671×0.2+1.2×1.764×0.2=4.531kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×13.83×0.2=3.043kN五、小梁验算小梁类型钢管小梁截面类型(mm) Φ48.3×3.0小梁计算截面类型(mm) Φ48×2.8小梁抗弯强度设计值[f](N/mm2) 205小梁抗剪强度设计值[τ](N/mm2) 125 小梁截面抵抗矩W(cm3) 4.25小梁弹性模量E(N/mm2) 206000 小梁截面惯性矩I(cm4) 10.19面板传递给小梁q1=4.531/0.6=7.551kN/m小梁自重q2=1×1.35×(0.3-0.1)×0.2=0.054kN/m梁左侧楼板及侧模传递给小梁荷载F1=1×max[1.2 ×(0.5+(24+1.1)×0.3)+1.4×3,1.35 ×(0.5+(24+1.1)×0.3)+1.4×0.7×3]×(0.4-0.6/2)/2×0.2+1×1.35×0.5×(0.9-0.3)×0.2=0.219kN梁右侧楼板及侧模传递给小梁荷载F2=1×max[1.2 ×(0.5+(24+1.1)×0.3)+1.4×3,1.35×(0.5+(24+1.1)×0.3)+1.4×0.7×3]×((0.8-0.4)-0.6/2)/2×0.2+1×1.35×0.5×(0.9-0.3)×0.2=0.219kN正常使用极限状态:面板传递给小梁q1=3.043/0.6=5.071kN/m小梁自重q2=1×(0.3-0.1)×0.2=0.04kN/m梁左侧楼板及侧模传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.3)×(0.4-0.6/2)/2×0.2+1×0.5×(0.9-0.3)×0.2=0.14kN 梁右侧楼板及侧模传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.3)×((0.8-0.4)-0.6/2)/2×0.2+1×0.5×(0.9-0.3)×0.2=0.14kN 计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.051×106/4250=11.946N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算小梁剪力图(kN)V max=1.146kNτmax=2V max/A=2×1.146×1000/398=5.759N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算小梁变形图(mm)νmax=0.006mm≤[ν]=L/250=267/250=1.068mm满足要求!4、支座反力计算承载能力极限状态R1=0.348kN,R2=2.158kN,R3=2.158kN,R4=0.348kN正常使用极限状态R'1=0.23kN,R'2=1.447kN,R'3=1.447kN,R'4=0.23kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48.3×3.0主梁计算截面类型(mm) Φ48×2.8主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19主梁计算方式三等跨连续梁可调托座内主梁根数 2主梁受力不均匀系数0.6由上节可知P=max[R2,R3]×0.6=1.295kN,P'=max[R2',R3']×0.6=0.868kN主梁计算简图一1、抗弯验算主梁弯矩图一(kN·m)σ=M max/W=0.337×106/4250=79.294N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图一(kN)V max=2.04kNτmax=2V max/A=2×2.04×1000/398=10.251N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图一(mm)跨中νmax=0.287mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.016mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=5.277kN用小梁的支座反力分别代入可得:承载能力极限状态图一立杆2:R2=5.277kN,立杆3:R3=5.277kN立杆所受主梁支座反力依次为:立杆2:P2=5.277/0.6=8.795kN,立杆3:P3=5.277/0.6=8.795kN七、纵向水平钢管验算钢管截面类型(mm) Φ48.3×3.0钢管计算截面类型(mm) Φ48×2.8钢管截面面积A(mm2) 398 钢管截面回转半径i(mm) 16钢管弹性模量E(N/mm2) 206000 钢管截面惯性矩I(cm4) 10.19 钢管截面抵抗矩W(cm3) 4.25 钢管抗弯强度设计值[f](N/mm2) 205 钢管抗剪强度设计值[τ](N/mm2) 1251414纵向水平钢管计算简图一1、抗弯验算纵向水平钢管弯矩图一(kN·m)σ=M max/W=0.09×106/4250=21.176N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算纵向水平钢管剪力图一(kN)V max=0.548kNτmax=2V max/A=2×0.548×1000/398=2.754N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算纵向水平钢管变形图一(mm)跨中νmax=0.076mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.004mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=1.418kN用小梁两侧的支座反力分别代入可得:承载能力极限状态图一:立杆1:R1=1.418kN,立杆4:R4=1.418kN八、可调托座验算两侧立杆最大受力N=max[R1,R4]=max[1.418,1.418]=1.418kN≤0.85×8=6.8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2,P3]=8.795kN≤[N]=30kN满足要求!九、立杆验算顶部立杆段:l01=kμ1(h d+2a)=1×1.386×(750+2×200)=1594mm非顶部立杆段:l02=kμ2h =1×1.755×1500=2632mmλ=max[l01,l02]/i=2632/16=164.5≤[λ]=210长细比满足要求!顶部立杆段:l01=kμ1(h d+2a)=1.155×1.386×(750+2×200)=1841mm非顶部立杆段:l02=kμ2h =1.155×1.755×1500=3041mmλ=max[l01,l02]/i=3041/16=190.062查表得:φ=0.1992、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1×0.6 ×1.4×(1×0.031×0.8×1.52/10)=0.005kN·m3、稳定性计算R1=1.418kN,P2=8.795kN,P3=8.795kN,R4=1.418kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1×max[1.2×(0.5+(24+1.1)×0.3)+1.4×3,1.35×(0.5+(24+1.1)×0.3)+0.7×1.4×3]×(0.8+0.4-0.6/2)/2×0.8=4.981kN右侧楼板传递给梁右侧立杆荷载:N边2=1×max[1.2×(0.5+(24+1.1)×0.3)+1.4×3,1.35×(0.5+(24+1.1)×0.3)+0.7×1.4×3]×(0.8+0.8-0.4-0.6/2)/2×0.8=4.981kNN d=max[R1+N边1,P2,P3,R4+N边2]+1×1.35×0.15×(3.6-0.9)=max[1.418+4.981,8.795,8.795,1.418+4.981]+0.547=9.342kNf d=N d/(φA)+M wd/W=9341.985/(0.199×398)+0.005×106/4250=119.128N/mm2≤[f]=205N/mm2满足要求!十、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=3.6/38=0.095≤3满足要求!十一、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.8×0.61=0.488kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.8×1×0.259=0.207kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×3.62×0.488+3.6×0.207=3.908kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j =B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=382×0.8×[0.15×3.6/(0.8×0.8)+0.5]+2×1×38/2=1590.3kN.m≥3γ0M ok =3×1×3.908=11.724kN.M满足要求!十二、立杆地基基础计算地基土类型素填土地基承载力特征值f ak(kPa) 140立杆垫木地基土承载力折减系数m f 1 垫板底面面积A(m2) 0.15立杆底垫板的底面平均压力p=N/(m f A)=9.342/(1×0.15)=62.28kPa≤γu f ak=1.363×140 =190.82kPa满足要求!。
梁。扣件式(与板立杆共用)-1
扣件式梁模板安全计算书一、计算依据1、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20112、《建筑施工脚手架安全技术统一标准》GB51210-20163、《建筑施工模板安全技术规范》JGJ162-20084、《建筑施工临时支撑结构技术规范》JGJ300-20135、《冷弯薄壁型钢结构技术规范》GB50018-20026、《建筑结构荷载规范》GB50009-20127、《钢结构设计规范》GB50017-20031、计算参数基本参数计算依据《建筑施工脚手架安全技术统一标准》GB51210-2016混凝土梁高h(mm) 650 混凝土梁宽b(mm) 450混凝土梁计算跨度L(m) 7.2 模板支架高度H(m) 1模板荷载传递方式可调托座次楞悬挑长度a1(mm) 250梁两侧楼板情况梁两侧有板梁侧楼板厚度h b(mm) 140剪刀撑(含水平)布置方式普通型梁跨度方向立杆间距l a(m) 11 水平杆步距h1(m) 1.3垂直梁跨度方向的梁两侧立杆间距l b(m)梁侧楼板立杆的纵距l a1(m) 1.3 梁侧楼板立杆的横距l b1(m) 1.3立杆自由端高度h0(mm) 400 梁底立杆根数n 1次楞根数m 4 架体底部布置类型底座结构表面要求表面外露材料参数主楞类型圆钢管主楞规格Ф48×3.0 主楞合并根数 2 次楞类型矩形木楞次楞规格40×80 次楞合并根数/面板类型覆面木胶合板面板规格12mm(克隆、山樟平行方向)钢管规格Ф48×3荷载参数可调托座承载力容许值(kN) 30 地基承载力特征值f ak(kPa) /0.2 架体底部垫板面积A(m2) 0.2 模板(不含支架)自重标准值G1k(kN/m2)24 钢筋自重标准值G3k(kN/m3) 1.5 新浇筑混凝土自重标准值G2k(kN/m3)0.5 施工荷载标准值Q k(kN/m2) 2 脚手架上震动、冲击物体自重Q DK(kN/m2)1.35 脚手架安全等级2级计算震动、冲击荷载时的动力系数κ脚手架结构重要性系数γ0 1 是否考虑风荷载否省份、城市河南(省)郑州地面粗糙度类型/市(市)/ 基本风压值W o(kN/m2) / 模板支撑架顶部模板高度H b(mm)/模板支撑架顶部竖向栏杆围挡的高度H m(mm)2、施工简图(图1)剖面图1(图2)剖面图2二、面板验算根据规范规定面板可按简支跨计算,根据施工情况一般楼板面板均搁置在梁侧模板上,无悬挑端,故可按简支跨一种情况进行计算,取b=1m单位面板宽度为计算单元。
350x800梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《混凝土结构设计规范》GB 50010-20103、《建筑结构荷载规范》GB 50009-20124、《钢结构设计规范》GB 50017-2003一、工程属性平面图立面图四、面板验算截面抵抗矩:W=bh2/6=350×18×18/6=18900mm3,截面惯性矩:I=bh3/12=350×18×18×18/12=170100mm4q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×0.8)+1.4×2,1.35×(0.1+(24+1.5)×0.8)+1.4×0.7×2]×0.35=9.3 35kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×0.8]×0.35=8.718kN/ mq1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×0.35=0.617kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.8)]×0.35=7.175kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×8.718×0.22+0.117×0.617×0.22=0.038kN·m σ=M max/W=0.038×106/18900=1.998N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×7.175×2004/(100×5400×170100)=0.085mm≤[ν]=L/40 0=200/400=0.5mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×8.718×0.2+1.2×0.617×0.2=2.066kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×7.175×0.2=1.579kN五、小梁验算面板传递给小梁q1=2.066/0.35=5.903kN/m小梁自重q2=0.9×1.35×(0.3-0.1)×0.2=0.049kN/m梁左侧楼板传递给小梁荷载F1=0.9×max[1.2 ×(0.5+(24+1.1)×0.12)+1.4×2,1.35 ×(0.5+(24+1.1)×0.12)+1.4×0.7×2]×(0.6-0.35/2)/2×0.2+0.9×1.35×0.5×(0.8-0.12)×0.2=0. 351kN梁右侧楼板传递给小梁荷载F2=0.9×max[1.2 ×(0.5+(24+1.1)×0.12)+1.4×2,1.35 ×(0.5+(24+1.1)×0.12)+1.4×0.7×2]×((1.2-0.6)-0.35/2)/2×0.2+0.9×1.35×0.5×(0.8-0.12)×0. 2=0.351kN正常使用极限状态:面板传递给小梁q1=1.579/0.35=4.51kN/m小梁自重q2=1×(0.3-0.1)×0.2=0.04kN/m梁左侧楼板传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.12)×(0.6-0.35/2)/2×0.2+1×0.5×( 0.8-0.12)×0.2=0.217kN梁右侧楼板传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.12)×((1.2-0.6)-0.35/2)/2×0.2+1×0.5×(0.8-0.12)×0.2=0.217kN计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.07×106/42670=1.651N/mm2≤[f]=11.44N/mm2 满足要求!2、抗剪验算小梁剪力图(kN)V max=1.042kNτmax=3V max/(2bh0)=3×1.042×1000/(2×40×80)=0.488N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算小梁变形图(mm)νmax=0.068mm≤[ν]=L/400=400/400=1mm满足要求!4、支座反力计算承载能力极限状态R1=0.12kN,R2=1.533kN,R3=1.533kN,R4=0.12kN正常使用极限状态R'1=0.089kN,R'2=1.12kN,R'3=1.12kN,R'4=0.089kN六、主梁验算由上节可知P=max[R1,R2,R3,R4]=1.533kN,P'=max[R1',R2',R3',R4']=1.12 kN主梁计算简图一1、抗弯验算主梁弯矩图一(kN·m)σ=M max/W=0.659×106/4250=155.059N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算主梁剪力图一(kN)V max=3.879kNτmax=2V max/A=2×3.879×1000/398=19.492N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图一(mm)跨中νmax=0.763mm≤[ν]=L/400=1000/400=2.5mm满足要求!悬臂端νmax=0.431mm≤[ν]=2l2/400=2×300/400=1.5mm满足要求!4、支座反力计算图一:R max=7.711kN用小梁的支座反力分别代入可得:承载能力极限状态图一立柱1:R1=0.604kN,立柱2:R2=7.711kN,立柱3:R3=7.711kN,立柱4:R4=0 .604kN七、扣件抗滑移验算1234c c满足要求!八、立柱验算l0=h=1800mmλ=l0/i=1800/16=112.5≤[λ]=150长细比满足要求!查表得,υ=0.5022、风荷载计算M w=0.9×υc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.207×1×1.82/10=0.076kN·m3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2008,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×0.8)+1.4×0.9×2]×0.35=8.543kN/m2)小梁验算F1=0.9×[1.2×(0.1+(24+1.1)×0.12)+1.4×0.9×1]×(0.6-0.35/2)/2×0.2+0.9×1.2×0.5×(0.8-0.12)×0.2=0.283kNF2=0.9×[1.2×(0.1+(24+1.1)×0.12)+1.4×0.9×1]×((1.2-0.6)-0.35/2)/2×0.2+0.9×1.2×0.5×(0.8-0.12)×0.2=0.283kNq1=5.415kN/mq2=0.043kN/m同上四~六计算过程,可得:R1=0.548kN,R2=6.866kN,R3=6.866kN,R4=0.548kN立柱最大受力N w=max[R1+N边1,R2,R3,R4+N边2]+0.9×1.2×0.1×(8.75-0.8)+M w/l b=max[0.548+0.9×[1.2×(0.5+(24+1.1)×0.12)+1.4×0.9×1]×(1+0.6-0.35/2)/2×1,6.866,6.8 66,0.548+0.9×[1.2×(0.5+(24+1.1)×0.12)+1.4×0.9×1]×(1+1.2-0.6-0.35/2)/2×1]+0.859+ 0.076/1.2=7.788kNf=N/(υA)+M w/W=7788.093/(0.502×398)+0.076×106/4250=56.863N/mm2≤[f]=205N/mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011第6.9.7:支架高宽比不应大于3H/B=8.75/22.73=0.385≤3满足要求,不需要进行抗倾覆验算!十、立柱支承面承载力验算11、受冲切承载力计算根据《混凝土结构设计规范》GB50010-2010第6.5.1条规定,见下表h t0u m =2[(a+h0)+(b+h0)]=800mmF=(0.7βh f t+0.25σpc,m)ηu m h0=(0.7×1×0.858+0.25×0)×1×800×100/1000=48.048kN≥F1=7. 788kN满足要求!2、局部受压承载力计算根据《混凝土结构设计规范》GB50010-2010第6.6.1条规定,见下表c cβl=(A b/A l)1/2=[(a+2b)×(b+2b)/(ab)]1/2=[(300)×(300)/(100×100)]1/2=3,A ln=ab=10000mm 2F=1.35βcβl f c A ln=1.35×1×3×7.488×10000/1000=303.264kN≥F1=7.788kN满足要求!。
400x800梁模板(扣件式,梁板立柱共用)计算书
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工脚手架安全技术统一标准》GB51210-20162、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20113、《建筑施工模板安全技术规范》JGJ162-20084、《混凝土结构设计规范》GB 50010-20105、《建筑结构荷载规范》GB 50009-20126、《钢结构设计标准》GB 50017-2017一、工程属性平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 18面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400 验算方式三等跨连续梁截面抵抗矩:W=bh2/6=400×18×18/6=21600mm3,截面惯性矩:I=bh3/12=400×18×18×18/12=194400mm4q1=γ0×max[1.2(G1k+(G2k+G3k)×h)+1.4Q1k,1.35(G1k+(G2k+G3k)×h)+1.4φc Q1k]×b=1×max[1.2×(0.1+(24+1.5)×0.8)+1.4×3,1.35×(0.1+(24+1.5)×0.8)+1.4×0.7×3]×0.4=12.246kN/mq1静=γ0×1.35×[G1k+(G2k+G3k)×h]×b=1×1.35×[0.1+(24+1.5)×0.8]×0.4=11.07kN/mq1活=γ0×1.4×0.7×Q1k×b=1×1.4×0.7×3×0.4=1.176kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.8)]×0.4=8.2kN/m简图如下:1、抗弯验算M max=0.1q1静L2+0.117q1活L2=0.1×11.07×0.22+0.117×1.176×0.22=0.05kN·mσ=M max/W=0.05×106/21600=2.305N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.677q2L4/(100EI)=0.677×8.2×2004/(100×5400×194400)=0.085mm≤[ν]=L/250=200/250=0.8mm满足要求!3、支座反力计算设计值(承载能力极限状态)R max=1.1q1静L+1.2q1活L=1.1×11.07×0.2+1.2×1.176×0.2=2.718kN标准值(正常使用极限状态)R'max=1.1q2L=1.1×8.2×0.2=1.804kN五、小梁验算小梁类型钢管小梁截面类型(mm) Φ48.3×3.0小梁计算截面类型(mm) Φ48×2.8小梁抗弯强度设计值[f](N/mm2) 205小梁抗剪强度设计值[τ](N/mm2) 125 小梁截面抵抗矩W(cm3) 4.25小梁弹性模量E(N/mm2) 206000 小梁截面惯性矩I(cm4) 10.19面板传递给小梁q1=2.718/0.4=6.794kN/m小梁自重q2=1×1.35×(0.3-0.1)×0.2=0.054kN/m梁左侧楼板及侧模传递给小梁荷载F1=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35 ×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×(0.4-0.4/2)/2×0.2+1×1.35×0.5×(0.8-0.25)×0.2=0.321kN梁右侧楼板及侧模传递给小梁荷载F2=1×max[1.2 ×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+1.4×0.7×3]×((0.8-0.4)-0.4/2)/2×0.2+1×1.35×0.5×(0.8-0.25)×0.2=0.321kN正常使用极限状态:面板传递给小梁q1=1.804/0.4=4.51kN/m小梁自重q2=1×(0.3-0.1)×0.2=0.04kN/m梁左侧楼板及侧模传递给小梁荷载F1=(1×0.5+1×(24+1.1)×0.25)×(0.4-0.4/2)/2×0.2+1×0.5×(0.8-0.25)×0.2=0.191kN 梁右侧楼板及侧模传递给小梁荷载F2=(1×0.5+1×(24+1.1)×0.25)×((0.8-0.4)-0.4/2)/2×0.2+1×0.5×(0.8-0.25)×0.2=0.191kN 计算简图如下:承载能力极限状态正常使用极限状态1、抗弯验算小梁弯矩图(kN·m)σ=M max/W=0.035×106/4250=8.166N/mm2≤[f]=205N/mm2 满足要求!2、抗剪验算小梁剪力图(kN)V max=0.911kNτmax=2V max/A=2×0.911×1000/398=4.577N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算小梁变形图(mm)νmax=0.005mm≤[ν]=L/250=267/250=1.068mm满足要求!4、支座反力计算承载能力极限状态R1=0.015kN,R2=1.687kN,R3=1.687kN,R4=0.015kN正常使用极限状态R'1=0.006kN,R'2=1.103kN,R'3=1.103kN,R'4=0.006kN六、主梁验算主梁类型钢管主梁截面类型(mm) Φ48.3×3.0主梁计算截面类型(mm) Φ48×2.8主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19主梁计算方式三等跨连续梁可调托座内主梁根数 2主梁受力不均匀系数0.6由上节可知P=max[R2,R3]×0.6=1.012kN,P'=max[R2',R3']×0.6=0.662kN主梁计算简图一1、抗弯验算主梁弯矩图一(kN·m)σ=M max/W=0.263×106/4250=61.882N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图一(kN)V max=1.594kNτmax=2V max/A=2×1.594×1000/398=8.01N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图一(mm)跨中νmax=0.219mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0.012mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=4.124kN用小梁的支座反力分别代入可得:承载能力极限状态图一立杆2:R2=4.124kN,立杆3:R3=4.124kN立杆所受主梁支座反力依次为:立杆2:P2=4.124/0.6=6.873kN,立杆3:P3=4.124/0.6=6.873kN七、纵向水平钢管验算钢管截面类型(mm) Φ48.3×3.0钢管计算截面类型(mm) Φ48×2.8钢管截面面积A(mm2) 398 钢管截面回转半径i(mm) 16钢管弹性模量E(N/mm2) 206000 钢管截面惯性矩I(cm4) 10.19 钢管截面抵抗矩W(cm3) 4.25 钢管抗弯强度设计值[f](N/mm2) 205 钢管抗剪强度设计值[τ](N/mm2) 1251414纵向水平钢管计算简图一1、抗弯验算纵向水平钢管弯矩图一(kN·m)σ=M max/W=0.004×106/4250=0.941N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算纵向水平钢管剪力图一(kN)V max=0.024kNτmax=2V max/A=2×0.024×1000/398=0.119N/mm2≤[τ]=125N/mm2 满足要求!3、挠度验算纵向水平钢管变形图一(mm)跨中νmax=0.002mm≤[ν]=L/250=800/250=3.2mm满足要求!悬臂端νmax=0mm≤[ν]=2l2/250=2×200/250=1.6mm满足要求!4、支座反力计算图一:R max=0.061kN用小梁两侧的支座反力分别代入可得:承载能力极限状态图一:立杆1:R1=0.061kN,立杆4:R4=0.061kN八、可调托座验算两侧立杆最大受力N=max[R1,R4]=max[0.061,0.061]=0.061kN≤0.85×8=6.8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2,P3]=6.873kN≤[N]=30kN满足要求!九、立杆验算顶部立杆段:l01=kμ1(h d+2a)=1×1.386×(750+2×200)=1594mm非顶部立杆段:l02=kμ2h =1×1.755×1500=2632mmλ=max[l01,l02]/i=2632/16=164.5≤[λ]=210长细比满足要求!顶部立杆段:l01=kμ1(h d+2a)=1.155×1.386×(750+2×200)=1841mm非顶部立杆段:l02=kμ2h =1.155×1.755×1500=3041mmλ=max[l01,l02]/i=3041/16=190.062查表得:φ=0.1992、风荷载计算M wd=γ0×φc×γQ×Mωk=γ0×φc×γQ×(ζ2×ωk×l a×h2/10)=1×0.6 ×1.4×(1×0.031×0.8×1.52/10)=0.005kN·m3、稳定性计算R1=0.061kN,P2=6.873kN,P3=6.873kN,R4=0.061kN梁两侧立杆承受楼板荷载:左侧楼板传递给梁左侧立杆荷载:N边1=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.4-0.4/2)/2×0.8=4.932kN右侧楼板传递给梁右侧立杆荷载:N边2=1×max[1.2×(0.5+(24+1.1)×0.25)+1.4×3,1.35×(0.5+(24+1.1)×0.25)+0.7×1.4×3]×(0.8+0.8-0.4-0.4/2)/2×0.8=4.932kNN d=max[R1+N边1,P2,P3,R4+N边2]+1×1.35×0.15×(3.6-0.8)=max[0.061+4.932,6.873,6.873,0.061+4.932]+0.567=7.44kNf d=N d/(φA)+M wd/W=7440.188/(0.199×398)+0.005×106/4250=95.116N/mm2≤[f]=205N/mm2满足要求!十、高宽比验算根据《建筑施工脚手架安全技术统一标准》GB51210-2016 第8.3.2条: 支撑脚手架独立架体高宽比不应大于3.0H/B=3.6/33=0.109≤3满足要求!十一、架体抗倾覆验算支撑脚手架风线荷载标准值:q wk=l'a×ωfk=0.8×0.586=0.469kN/m:风荷载作用在支架外侧模板上产生的水平力标准值:F wk= l'a×H m×ωmk=0.8×1×0.259=0.207kN支撑脚手架计算单元在风荷载作用下的倾覆力矩标准值M ok:M ok=0.5H2q wk+HF wk=0.5×3.62×0.469+3.6×0.207=3.784kN.m参考《规范》GB51210-2016 第6.2.17条:B2l'a(g k1+ g k2)+2ΣG jk b j≥3γ0M okg k1——均匀分布的架体面荷载自重标准值kN/m2g k2——均匀分布的架体上部的模板等物料面荷载自重标准值kN/m2G jk——支撑脚手架计算单元上集中堆放的物料自重标准值kNb j——支撑脚手架计算单元上集中堆放的物料至倾覆原点的水平距离mB2l'a(g k1+ g k2)+2ΣG jk b j =B2l'a[qH/(l'a×l'b)+G1k]+2×G jk×B/2=332×0.8×[0.15×3.6/(0.8×0.8)+0.5]+2×1×33/2=1203.675kN.m≥3γ0M ok =3×1×3.784=11.351kN.M满足要求!十二、立杆地基基础计算地基土类型素填土地基承载力特征值f ak(kPa) 140立杆垫木地基土承载力折减系数m f 1 垫板底面面积A(m2) 0.15立杆底垫板的底面平均压力p=N/(m f A)=7.44/(1×0.15)=49.601kPa≤γu f ak=1.363×140 =190.82kPa满足要求!。
梁模板(扣件式-梁板立柱共用)计算书(采用)共10页word资料
梁模板(扣件式,梁板立柱共用)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20192、《建筑施工扣件式钢管脚手架安全技术规范》JGJ 130-20193、《混凝土结构设计规范》GB 50010-20194、《建筑结构荷载规范》GB 50009-20195、《钢结构设计规范》GB 50017-2019一、工程属性平面图立面图四、面板验算W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×1.9)+1.4×2,1.35×(0.1+(24+1.5)×1.9)+1.4×0.7×2]×1=60.752kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×1.9]×1=58.988kN/mq1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×1.9)]×1=48.55kN/m计算简图如下:1、强度验算M max=0.107q1静L2+0.121q1活L2=0.107×58.988×0.0752+0.121×1.764×0.0752=0.037kN·mσ=M max/W=0.037×106/37500=0.979N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.632q2L4/(100EI)=0.632×48.55×754/(100×5400×281250)=0.006mm≤[ν]=L/250=75/250=0.3mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R5=0.393q1静L+0.446q1活L=0.393×58.988×0.075+0.446×1.764×0.075=1.798kNR2=R4=1.143q1静L+1.223q1活L=1.143×58.988×0.075+1.223×1.764×0.075=5.219kNR3=0.928q1静L+1.142q1活L=0.928×58.988×0.075+1.142×1.764×0.075=4.257kN 标准值(正常使用极限状态)R1'=R5'=0.393q2L=0.393×48.55×0.075=1.431kNR2'=R4'=1.143q2L=1.143×48.55×0.075=4.162kNR3'=0.928q2L=0.928×48.55×0.075=3.379kN五、小梁验算梁底面板传递给左边小梁线荷载:q1左=R1/b=1.798/1=1.798kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3,R4]/b = Max[5.219,4.257,5.219]/1= 5.219kN/m梁底面板传递给右边小梁线荷载:q1右=R5/b=1.798/1=1.798kN/m小梁自重:q2=0.9×1.35×(0.3-0.1)×0.3/4 =0.018kN/m梁左侧模板传递给左边小梁荷载q3左=0.9×1.35×0.5×(1.9-0.12)=1.081kN/m梁右侧模板传递给右边小梁荷载q3右=0.9×1.35×0.5×(1.9-0.12)=1.081kN/m梁左侧楼板传递给左边小梁荷载q4左=0.9×Max[1.2×(0.5+(24+1.1)×0.12)+1.4×2,1.35×(0.5+(24+1.1)×0.12)+1.4×0.7×2]×(0.4-0.3/2)/2×1=0.789kN/m梁右侧楼板传递给右边小梁荷载q4右=0.9×Max[1.2×(0.5+(24+1.1)×0.12)+1.4×2,1.35×(0.5+(24+1.1)×0.12)+1.4×0.7×2]×((0.8-0.4)-0.3/2)/2×1=0.789kN/m左侧小梁荷载q左=q1左+q2+q3左+q4左=1.798+0.018+1.081+0.789=3.686kN/m中间小梁荷载q中= q1中+ q2=5.219+0.018=5.237kN/m右侧小梁荷载q右=q1右+q2+q3右+q4右=1.798+0.018+1.081+0.789=3.686kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[3.686,5.237,3.686]=5.237kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=1.431/1=1.431kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3',R4']/b = Max[4.162,3.379,4.162]/1= 4.162kN/m梁底面板传递给右边小梁线荷载:q1右'=R5'/b=1.431/1=1.431kN/m小梁自重:q2'=1×(0.3-0.1)×0.3/4 =0.015kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×(1.9-0.12)=0.89kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×(1.9-0.12)=0.89kN/m梁左侧楼板传递给左边小梁荷载q4左'=[1×(0.5+(24+1.1)×0.12)]×(0.4-0.3/2)/2×1=0.439kN/m梁右侧楼板传递给右边小梁荷载q4右'=[1×(0.5+(24+1.1)×0.12)]×((0.8-0.4)-0.3/2)/2×1=0.439kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'+q4左'=1.431+0.015+0.89+0.439=2.775kN/m 中间小梁荷载q中'= q1中'+ q2'=4.162+0.015=4.177kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'+q4右' =1.431+0.015+0.89+0.439=2.775kN/m 小梁最大荷载q'=Max[q左',q中',q右']=Max[2.775,4.177,2.775]=4.177kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×5.237×0.32,0.5×5.237×0.12]=0.059kN·mσ=M max/W=0.059×106/20833=2.828N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×5.237×0.3,5.237×0.1]=0.786kNτmax=3V max/(2bh0)=3×0.786×1000/(2×50×50)=0.471N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×4.177×3004/(384×7040×52.083×104)=0.12mm≤[ν]=l1/250=300/250=1.2mmν2=q'l24/(8EI)=4.177×1004/(8×7040×52.083×104)=0.014mm≤[ν]=2l2/250=2×100/250=0.8mm满足要求!4、支座反力计算承载能力极限状态R max=[qL1,0.5qL1+qL2]=max[5.237×0.3,0.5×5.237×0.3+5.237×0.1]=1.571kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=1.106kN,R2=1.571kN,R3=1.282kN,R4=1.571kN,R5=1.106kN正常使用极限状态R max'=[q'L1,0.5q'L1+q'L2]=max[4.177×0.3,0.5×4.177×0.3+4.177×0.1]=1.253kN同理可得:梁底支撑小梁所受最大支座反力依次为R1'=0.832kN,R2'=1.253kN,R3'=1.018kN,R4'=1.253kN,R5'=0.832kN六、主梁验算主梁弯矩图(kN·m)σ=M max/W=0.171×106/4250=40.274N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图(kN)V max=2.395kNτmax=2V max/A=2×2.395×1000/398=12.034N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=0.028mm≤[ν]=L/250=400/250=1.6mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.282kN,R2=6.072kN,R3=0.282kN正常使用极限状态支座反力依次为R1'=0.216kN,R2'=4.756kN,R3'=0.216kN七、2号主梁验算P=max[R2]×0.6=Max[6.072]×0.6=3.643kN,P'=max[R2']×0.6=Max[4.756]×0.6=2.854kN1、抗弯验算2号主梁弯矩图(kN·m)σ=M max/W=0.383×106/4250=90.008N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算2号主梁剪力图(kN)V max=2.368kNτmax=2V max/A=2×2.368×1000/398=11.9N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算2号主梁变形图(mm)νmax=0.34mm≤[ν]=L/250=600/250=2.4mm满足要求!4、支座反力计算极限承载能力状态支座反力依次为R1=4.918kN,R2=7.832kN,R3=7.833kN,R4=4.918kN 立柱所受主梁支座反力依次为P2=7.833/0.6=13.054kN八、纵向水平钢管验算1313计算简图如下:1、抗弯验算纵向水平钢管弯矩图(kN·m)σ=M max/W=0.03×106/4250=6.967N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算纵向水平钢管剪力图(kN)V max=0.183kNτmax=2V max/A=2×0.183×1000/398=0.921N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算纵向水平钢管变形图(mm)νmax=0.026mm≤[ν]=L/250=600/250=2.4mm满足要求!4、支座反力计算支座反力依次为R1=0.381kN,R2=0.606kN,R3=0.606kN,R4=0.381kN同理可得:两侧立柱所受支座反力依次为R1=0.606kN,R3=0.606kN九、可调托座验算两侧立柱最大受力N=max[R1,R3]=max[0.606,0.606]=0.606kN≤1×8=8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[P2]=13.054kN≤[N]=30kN满足要求!十、立柱验算l0=h=1200mmλ=l0/i=1200/16=75≤[λ]=150长细比满足要求!查表得,φ=0.752、风荷载计算M w=0.9×φc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.29×0.6×1.22/10=0.028kN·m3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2019,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×1.9)+1.4×0.9×2]×1=54.702kN/m2)小梁验算q1=max{1.621+0.9×1.2×[(0.3-0.1)×0.3/4+0.5×(1.9-0.12)]+0.9×[1.2×(0.5+(24+1.1)×0.12)+1. 4×0.9×1]×max[0.4-0.3/2,(0.8-0.4)-0.3/2]/2×1,4.703+0.9×1.2×(0.3-0.1)×0.3/4}=4.719kN/m同上四~八计算过程,可得:R1=0.533kN,P2=11.655kN,R3=0.533kN立柱最大受力N w=max[R1+N边1,P2,R3+N边2]+0.9×1.2×0.15×(5.2-1.9)+M w/l b =max[0.533+0.9×[1.2×(0.5+(24+1.1)×0.12)+1.4×0.9×1]×(0.6+0.4-0.3/2)/2×0.6,11.655,0.533+0.9×[1.2×(0.5+(24+1.1)×0.12)+1.4×0.9×1]×(0.6+0.8-0.4-0.3/2)/2×0.6]+0.535+0.0 28/0.8=12.225kNf=N/(φA)+M w/W=12225.465/(0.75×398)+0.028×106/4250=47.545N/mm2≤[f]=205N/mm2满足要求!十一、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2019 第6.9.7:支架高宽比不应大于3H/B=5.2/37=0.141<3满足要求,不需要进行抗倾覆验算!十二、立柱地基基础计算f ak 140kPa满足要求!。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
梁模板(810*600)计算书计算依据:1、《建筑施工模板安全技术规范》JGJ162-20082、《混凝土结构设计规范》GB 50010-20103、《建筑结构荷载规范》GB 50009-20124、《钢结构设计规范》GB 50017-2003一、工程属性二、荷载设计三、模板体系设计设计简图如下:平面图立面图四、面板验算面板类型覆面木胶合板面板厚度t(mm) 15面板抗弯强度设计值[f](N/mm2) 15 面板抗剪强度设计值[τ](N/mm2) 1.5面板弹性模量E(N/mm2) 5400取单位宽度b=1000mm,按四等跨连续梁计算:W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=281250mm4 q1=0.9×max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4ψc Q2k]×b=0.9×max[1.2×(0.1+(24+1.5)×0.6)+1.4×2,1.35×(0.1+(24+1.5)×0.6)+1.4×0.7×2]×1=20.47 5kN/mq1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×0.6]×1=18.711kN/m q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.764kN/mq2=[1×(G1k+(G2k+G3k)×h)]×b=[1×(0.1+(24+1.5)×0.6)]×1=15.4kN/m计算简图如下:1、强度验算M max=0.107q1静L2+0.121q1活L2=0.107×18.711×0.1622+0.121×1.764×0.1622=0.058kN ·mσ=M max/W=0.058×106/37500=1.551N/mm2≤[f]=15N/mm2满足要求!2、挠度验算νmax=0.632q2L4/(100EI)=0.632×15.4×1624/(100×5400×281250)=0.044mm≤[ν]=L/400=162/400=0.405mm满足要求!3、支座反力计算设计值(承载能力极限状态)R1=R5=0.393q1静L+0.446q1活L=0.393×18.711×0.162+0.446×1.764×0.162=1.319kNR2=R4=1.143q1静L+1.223q1活L=1.143×18.711×0.162+1.223×1.764×0.162=3.814kN R3=0.928q1静L+1.142q1活L=0.928×18.711×0.162+1.142×1.764×0.162=3.139kN 标准值(正常使用极限状态)R1'=R5'=0.393q2L=0.393×15.4×0.162=0.98kNR2'=R4'=1.143q2L=1.143×15.4×0.162=2.852kNR3'=0.928q2L=0.928×15.4×0.162=2.315kN五、小梁验算承载能力极限状态:梁底面板传递给左边小梁线荷载:q1左=R1/b=1.319/1=1.319kN/m梁底面板传递给中间小梁最大线荷载:q1中=Max[R2,R3,R4]/b=Max[3.814,3.139,3.81 4]/1=3.814kN/m梁底面板传递给右边小梁线荷载:q1右=R5/b=1.319/1=1.319kN/m小梁自重:q2=0.9×1.35×(0.3-0.1)×0.81/5 =0.039kN/m梁左侧模板传递给左边小梁荷载q3左=0.9×1.35×0.5×0.6=0.365kN/m梁右侧模板传递给右边小梁荷载q3右=0.9×1.35×0.5×0.6=0.365kN/m左侧小梁荷载q左=q1左+q2+q3左=1.319+0.039+0.365=1.723kN/m中间小梁荷载q中= q1中+ q2=3.814+0.039=3.854kN/m右侧小梁荷载q右=q1右+q2+q3右=1.319+0.039+0.365=1.723kN/m小梁最大荷载q=Max[q左,q中,q右]=Max[1.723,3.854,1.723]=3.854kN/m正常使用极限状态:梁底面板传递给左边小梁线荷载:q1左'=R1'/b=0.98/1=0.98kN/m梁底面板传递给中间小梁最大线荷载:q1中'=Max[R2',R3',R4']/b=Max[2.852,2.315,2.8 52]/1=2.852kN/m梁底面板传递给右边小梁线荷载:q1右'=R5'/b=0.98/1=0.98kN/m小梁自重:q2'=1×(0.3-0.1)×0.81/5 =0.032kN/m梁左侧模板传递给左边小梁荷载q3左'=1×0.5×0.6=0.3kN/m梁右侧模板传递给右边小梁荷载q3右'=1×0.5×0.6=0.3kN/m左侧小梁荷载q左'=q1左'+q2'+q3左'=0.98+0.032+0.3=1.313kN/m中间小梁荷载q中'= q1中'+ q2'=2.852+0.032=2.884kN/m右侧小梁荷载q右'=q1右'+q2'+q3右'=0.98+0.032+0.3=1.313kN/m小梁最大荷载q'=Max[q左',q中',q右']=Max[1.313,2.884,1.313]=2.884kN/m为简化计算,按简支梁和悬臂梁分别计算,如下图:1、抗弯验算M max=max[0.125ql12,0.5ql22]=max[0.125×3.854×0.852,0.5×3.854×0.22]=0.348kN·mσ=M max/W=0.348×106/54000=6.446N/mm2≤[f]=11.44N/mm2满足要求!2、抗剪验算V max=max[0.5ql1,ql2]=max[0.5×3.854×0.85,3.854×0.2]=1.638kNτmax=3V max/(2bh0)=3×1.638×1000/(2×40×90)=0.682N/mm2≤[τ]=1.232N/mm2满足要求!3、挠度验算ν1=5q'l14/(384EI)=5×2.884×8504/(384×7040×243×104)=1.146mm≤[ν]=l1/400=850/ 400=2.125mmν2=q'l24/(8EI)=2.884×2004/(8×7040×243×104)=0.034mm≤[ν]=2l2/400=2×200/400=1mm满足要求!4、支座反力计算承载能力极限状态R max=[qL1,0.5qL1+qL2]=max[3.854×0.85,0.5×3.854×0.85+3.854×0.2]=3.276kN同理可得:梁底支撑小梁所受最大支座反力依次为R1=1.465kN,R2=3.276kN,R3=2.702kN,R4=2.7 02kN,R5=3.276kN,R6=1.465kN正常使用极限状态R max'=[q'L1,0.5q'L1+q'L2]=max[2.884×0.85,0.5×2.884×0.85+2.884×0.2]=2.451kN 同理可得:梁底支撑小梁所受最大支座反力依次为R1'=1.116kN,R2'=2.451kN,R3'=1.996kN,R4'=1.996kN,R5'=2.451kN,R6'=1.116kN六、主梁验算主梁类型钢管主梁截面类型(mm) Ф48×3主梁计算截面类型(mm) Φ48×2.8主梁抗弯强度设计值[f](N/mm2) 205主梁抗剪强度设计值[τ](N/mm2) 125 主梁截面抵抗矩W(cm3) 4.25主梁弹性模量E(N/mm2) 206000 主梁截面惯性矩I(cm4) 10.19可调托座内主梁根数 11、抗弯验算主梁弯矩图(kN·m)σ=M max/W=0.789×106/4250=185.584N/mm2≤[f]=205N/mm2满足要求!2、抗剪验算主梁剪力图(kN)V max=5.978kNτmax=2V max/A=2×5.978×1000/398=30.041N/mm2≤[τ]=125N/mm2满足要求!3、挠度验算主梁变形图(mm)νmax=1.639mm≤[ν]=L/400=1000/400=2.5mm满足要求!4、支座反力计算承载能力极限状态支座反力依次为R1=0.129kN,R2=1.015kN,R3=8.33kN,R4=8.329kN,R5=1.016kN ,R6=0.129kN七、可调托座验算1、扣件抗滑移验算两侧立柱最大受力N=max[R1,R6]=max[0.129,0.129]=0.129kN≤1×8=8kN 单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!2、可调托座验算可调托座最大受力N=max[R2,R3,R4,R5]=8.33kN≤[N]=30kN满足要求!八、立柱验算1、长细比验算l0=h=1700mmλ=l0/i=1700/16=106.25≤[λ]=150长细比满足要求!查表得,φ=0.5442、风荷载计算M w=0.9×φc×1.4×ωk×l a×h2/10=0.9×0.9×1.4×0.207×0.85×1.72/10=0.058kN·m 3、稳定性计算根据《建筑施工模板安全技术规范》JGJ162-2008,荷载设计值q1有所不同:1)面板验算q1=0.9×[1.2×(0.1+(24+1.5)×0.6)+1.4×0.9×2]×1=18.9kN/m2)小梁验算q1=max{1.223+0.9×1.2×[(0.3-0.1)×0.81/5+0.5×0.6],3.529+0.9×1.2×(0.3-0.1)×0.81/5} =3.564kN/m同上四~六计算过程,可得:R1=0.12kN,R2=0.942kN,R3=7.708kN,R4=7.708kN,R5=0.942kN,R6=0.12 kN立柱最大受力N w=max[R1,R2,R3,R4,R5,R6]+0.9×1.2×0.1×(11.6-0.6)+M w/l b=max[0.12,0.942,7.708,7.708,0.942,0.12]+1.188+0.058/4.4=8.909kNf=N/(φA)+M w/W=8909.483/(0.544×398)+0.058×106/4250=54.797N/mm2≤[f]=205N /mm2满足要求!九、高宽比验算根据《建筑施工扣件式钢管脚手架安全技术规范》JGJ130-2011第6.9.7:支架高宽比不应大于3H/B=11.6/6=1.933≤3满足要求,不需要进行抗倾覆验算!十、立柱支承面承载力验算F1=N=8.909kN1、受冲切承载力计算根据《混凝土结构设计规范》GB50010-2010第6.5.1条规定,见下表可得:βh=1,f t=0.858N/mm2,η=1,h0=h-20=100mm,u m =2[(a+h0)+(b+h0)]=800mmF=(0.7βh f t+0.25σpc,m)ηu m h0=(0.7×1×0.858+0.25×0)×1×800×100/1000=48.048kN≥F1=8. 909kN满足要求!2、局部受压承载力计算根据《混凝土结构设计规范》GB50010-2010第6.6.1条规定,见下表可得:f c=7.488N/mm2,βc=1,βl=(A b/A l)1/2=[(a+2b)×(b+2b)/(ab)]1/2=[(300)×(300)/(100×100)]1/2=3,A ln=ab=10000mm 2F=1.35βcβl f c A ln=1.35×1×3×7.488×10000/1000=303.264kN≥F1=8.909kN满足要求!。