EF 多模适配器
Powerline 1000 + Extra Outlet 双功能网线适配器说明书
Quick Start Powerline 1000 + Extra OutletModel PLP1000Package ContentsIn some regions, a resource CD is included with your product.Getting StartedPowerline adapters give you an alternative way to extend your network using your existing electrical wiring. Plug two or more Powerline adapters into electrical outlets to create a wired network connection. You can add up to 16 adapters to extend your network.Meet Your AdapterBefore you install your adapter, familiarize yourself with its LEDs,buttons, and port.Ethernet port Security buttonFactory Reset buttonPower LEDEthernet LEDPick A Plug LEDPower LEDSolid green . The electrical power is on.Solid amber . The adapter is in power saving mode.Blinking green . The adapter is in the process of setting up security.Off . The adapter is not receiving electrical power.Ethernet LEDSolid green . The Ethernet port is linked.Off . No Ethernet connection is detected.Pick A Plug LEDThe Pick A Plug feature lets you pick the electrical outlet with the strongest link performance, indicated by the colordisplayed by the LED:Red . Link rate < 50 Mbps (good).Amber . Link rate > 50 and < 80 Mbps (better).Green . Link rate > 80 Mbps (best).Off . The adapter did not find any other compatible Powerline devices using the same encryption key.Factory Reset button Press the Factory Reset button for one second, then releaseit to return the Powerline adapter to its factory default settings.Ethernet port Use an Ethernet cable to connect your wired devices,including computers, WiFi routers, or game consoles, to yourPowerline network.Security button Use the Security button to create a secure Powerlinenetwork.Install Your AdaptersRoom 1Room 2Secure Your Network¾To create a secure network:1. Plug in your new adapters.2. Wait until the Pick A Plug LEDs are lit.3. Press the Security button on one of the adapters for two seconds,then press the Security button on one of the other adapters in your existing network for two seconds.Both buttons must be pressed within two minutes.4. If you are installing additional adapters, repeat Step 3 with one of thesecure adapters and one of the adapters that is not yet secured. Note: The Security button does not work in power saving mode (see Troubleshooting Tips on page 10).Warning: Do not press the Security button on the Powerline adapter until installation is complete and the adapters are communicating with each other (indicated by the blinking Pick A Plug LED). Pressing this button too soon can temporarily disable Powerline communication. If this occurs, use the Factory Reset button to return the Powerline adapter to its factory default settings.Add AdaptersTo add adapters before you configure the security feature, just plug them in and connect the adapters to your equipment.¾To add adapters to a Powerline network with security set:1. Plug in and connect the new adapters.2. On any of the adapters that are already a part of the secure network,press and hold the Security button for two seconds.3. On the new adapter, press and hold the Security button for twoseconds.Both buttons must be pressed within two minutes.Troubleshooting TipsPower LED is off.Make sure that power is supplied to the electricaloutlet, and that the Powerline devices are not pluggedinto an extension cord, power strip, or surge protector.Power LED is blinking amber.Power saving mode occurs when the Ethernet LED is off. This can occur in the following circumstances:• The Ethernet cable is unplugged.• The device connected through the Ethernet cable is turned off.• The adapter is idle for 10 minutes.It returns to normal mode within two secondsafter the Ethernet link is up.Pick A Plug LED is off.• If you already set network security, make surethat all Powerline devices are using the sameencryption key. See the online user manual fordetails.• Press the Factory Reset button on each devicefor one second to return the Powerline adapter toits factory default settings.Pick A Plug LED is amber or red.Something is interfering with communication between adapters. To resolve this, do the following:• Move the adapter to another outlet.• Unplug devices that might be causing interference such as surge suppressors and items with motors.Ethernet LED is off.• Make sure that the Ethernet cables are workingand securely plugged into the devices.• Press the Factory Reset button on each devicefor one second to return the Powerline adapter toits factory default settings.11October 2016NETGEAR INTL LTD Building 3, University Technology CentreCurraheen Road, Cork, IrelandNETGEAR, Inc. 350 East Plumeria DriveSan Jose, CA 95134, USA SupportThank you for purchasing this NETGEAR product. You can visit /support to register your product, get help, access the latest downloads and user manuals, and join our community. We recommend that you use only official NETGEAR support resources.Trademarks© NETGEAR, Inc., NETGEAR and the NETGEAR Logo are trademarks of NETGEAR, Inc. Any non‑NETGEAR trademarks are used for reference purposes only.ComplianceFor the current EU Declaration of Conformity, visit: /app/answers/detail/a_id/11621.For regulatory compliance information, visit: /about/regulatory/.See the regulatory compliance document before connecting the power supply..。
适配器工作原理
适配器工作原理
适配器是一种设计模式,用于将不兼容的接口转换为可兼容的接口。
它允许两个或多个接口之间的协作,使它们能够正常工作。
适配器的工作原理如下:
1. 理解原始接口:适配器首先需要了解原始接口的结构和功能。
这包括了原始接口的方法、属性和行为。
2. 定义目标接口:适配器根据需要定义目标接口,使其与原始接口兼容。
目标接口包含了适配器将要提供给客户端的方法、属性和行为。
3. 实现适配器类:适配器类是实现适配器模式的核心组件。
它通过继承或组合原始接口并实现目标接口,完成了将原始接口转换为目标接口的功能。
4. 实现适配逻辑:适配器类根据原始接口和目标接口之间的差异,实现适配逻辑。
这可以包括将原始接口的方法调用映射到目标接口的方法,或者进行数据转换和处理以适应目标接口的要求。
5. 客户端使用适配器:客户端通过实例化适配器对象,并使用适配器提供的目标接口方法来访问原始接口。
客户端不需要直接实例化原始接口,也不需要了解原始接口的实现细节。
适配器工作原理的核心思想是将原始接口转换为目标接口,并提供一个统一的接口供客户端使用。
这样,即使原始接口发生变化,客户端也不需要做出任何改动,只需要适配器做相应的调整即可。
这提供了一种灵活和可扩展的方式来处理不兼容的接口。
多模光模块的传输适配
多模光模块的传输适配
多模光模块的传输适配主要指的是在多模光纤传输中,使用不同类型的多模光模块进行兼容和适配。
多模光模块通常使用的是多模光纤,其核心直径较大,光信号传输时会发生多次反射,导致光信号衰减和色散。
在多模光纤传输中,有几种常见的多模光模块,包括全高清(850nm)、千兆以太网(850nm)和万兆以太网(850nm或1310nm)等。
这些不同类型的光模块在传输速率、波长和传输距离等方面存在差异。
为了实现多模光模块的传输适配,可以采用以下方法:
1. 选择适配的光模块:根据需要的传输速率和距离,选择适配的光模块。
例如,千兆以太网模块适用于千兆以太网传输,而全高清模块适用于全高清视频传输。
选择合适的光模块可以确保信号的正常传输。
2. 使用适配器和转换器:如果需要将不同类型的光模块连接在一起,可以使用适配器和转换器进行光信号的转换和适配。
适配器和转换器可以将不同类型的光模块接口连接在一起,并确保信号的正确传输。
3. 调节光纤衰减:由于多模光纤传输中存在光信号衰
减,可能需要在光传输过程中添加适当的光纤衰减器来调节信号的强度,以保证信号能够稳定传输。
总之,多模光模块的传输适配需要根据具体的传输需求选择合适的光模块,并结合适配器、转换器和光纤衰减器等设备实现信号的兼容和适配。
ETHERSCOPE SERIES II 说明文档
有限担保和责任限制
Fluke Networks 担保在正常使用和保养的情况下,其产品没有材料和工艺上的缺陷。主机的担保期为购买产品之日起一年。如无另外规定,部 件、零配件、产品修理和服务的担保期为 90 天。Ni-Cad (镍镉), Ni-MH (镍氢)和 Li-Ion (锂离子)电池、电缆或其它外围设备均被视作 部件或零配件。本担保仅适用于 Fluke Networks 授权零售商的原始买方或最终用户,本担保不适用于任何 Fluke Networks 公司认为由于误 用、滥用、改造、疏忽、污染或因事故或非正常的操作和使用而导致损坏的产品。Fluke Networks 担保软件能够在完全符合性能指标的条件下 至少操作 90 天,并且软件是正确地记录在无缺陷的媒体上。Fluke Networks 并不担保软件毫无错误或在运行过程中不出现中断的情况。
7. 补偿。Fluke Networks 的全部责任及您可以得到的唯一补偿,是由 Fluke Networks 决定是否:(a) 退还您购买产品的价款,或 (b) 修复或更 换不能满足有限保证要求的软件产品。 如果产品的故障是由意外事故、滥用或误用产品引起,则本有限保证无效。 任何更换过的软件产品将享 受原九十 (90)天保证期的剩余部分时间或为期三十 (30)天的保证,以较长者为准。
特性 ................................................................................................................................................................................. 1 包装内容 .......................................................................................................................................................................... 2 安全和操作须知 ............................................................................................................................................................... 5 仪表注册 .......................................................................................................................................................................... 7 保养和维护 ...................................................................................................................................................................... 7 联系 Fluke Networks ...................................................................................................................................................... 8 使用前须知 ............................................................................................................................................................................. 8 使用触摸笔 ...................................................................................................................................................................... 9 启动和关闭仪表 ............................................................................................................................................................... 9 选择 LAN 或 WLAN 接口 ................................................................................................................................................. 10 更新软件 .......................................................................................................................................................................... 10
Emulex CN4052S 和 CN4054S 10Gb VFA5.2 适配器商品说明说明书
Emulex CN4052S and CN4054S 10Gb VFA5.2 Adapters for Flex SystemProduct GuideThe CN4054S 4-port and CN4052S 2-port 10Gb Virtual Fabric Adapters are VFA5.2 adapters that are supported on ThinkSystem and Flex System compute nodes.The CN4052S can be divided into up to eight virtual NIC (vNIC) devices per port (for a total of 16 vNICs) and the CN4054S can be divided in to four vNICs (for a total of 16 vNICs). Each vNIC can have flexible bandwidth allocation. These adapters also feature RDMA over Converged Ethernet (RoCE) capability, and support iSCSI, and FCoE protocols, either as standard or with the addition of a Features on Demand (FoD) license upgrade.The adapters are shown in the following figure. The CN4054S and CN4052S look the same.Figure 1. Flex System CN4054S and CN4052S 10Gb Virtual Fabric AdaptersDid you know?The CN4054S and CN4052S are based on the new Emulex XE100-P2 "Skyhawk P2" ASIC which enables better performance, especially with the new RDMA over Converged Ethernet v2 (RoCE v2) support. In addition, these adapters are supported by Lenovo XClarity Administrator, which allows you to deploy adapter settings easier and incorporate the adapters in configuration patterns.The CN4052S adapter now supports 8 vNICs per port using UFP or vNIC2 and with adapter firmware 10.6 or later. This means a total of 16 vNICs are supported. The CN4054S still supports 4 vNICs per port.Click here to check for updatesIn pNIC mode, an adapter with the FoD upgrade applied operates in traditional Converged Network Adapter (CNA) mode with four ports (CN4054S) or two ports (CN4052S) of Ethernet and four ports (CN4054S) or two ports (CN4052S) of iSCSI or FCoE available to the operating system.Server supportThe following table lists the ThinkSystem and Flex System compute nodes that support the adapters. Table 2. Support for Flex System compute nodesPartnumber DescriptionAdapters - ThinkSystem and Flex System compute nodes01CV780Flex System CN4052S 2-port 10Gb Virtual FabricAdapter AdvancedN N Y Y Y Y Y Y Y Y00AG540Flex System CN4052S 2-port 10Gb Virtual FabricAdapterN N Y Y Y N Y Y Y Y00AG590Flex System CN4054S 4-port 10Gb Virtual FabricAdapterY Y Y Y Y Y Y Y Y Y Features on Demand upgrades - Flex System compute nodes only00JY804Flex System CN4052 Virtual Fabric Adapter SWUpgrade (FoD)Y Y Y Y Y Y Y N N N00AG594Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter SW Upgrade (FoD)Y Y Y Y Y Y Y N N N x24(8737,E5-26v2)x24(7162)x24M5(9532,E5-26v3)x24M5(9532,E5-26v4)x44(7167)x88/x48/x28X6(793)x28/x48/x88X6(7196)SN55(7X16)SN85(7X15)SN55V2(7Z69)I/O module supportThese adapters can be installed in any I/O adapter slot of a supported Flex System compute node. One or two compatible 1 Gb or 10 Gb I/O modules must be installed in the corresponding I/O bays in the chassis. The following table lists the switches that are supported. When connected to the 1 Gb switch, the adapter will operate at 1 Gb speeds. When connected to the 40 Gb switch, the adapter will operate at 10 Gb speeds.To maximize the number of adapter ports usable, you may also need to order switch upgrades to enable additional ports. Alternatively, for CN4093, EN4093R, and SI4093 switches, you can use Flexible Port Mapping (FPM), a feature of Networking OS 7.8 or later, that allows you to minimize the number of upgrades needed.See the Product Guides for the Flex System switches for more details about switch upgrades and FPM: https:///servers/blades/networkmoduleThe table below specifies how many ports the adapters contain. For the CN4054S, to enable all 4 adapter ports, either upgrade the switch or use Flexible Port Mapping. Switches should be installed in pairs to maximize the number of ports enabled and to provide redundant network connections.Table 3. I/O modules supportedPartnumber Description CN4052Sports†CN4054Sports†4SG7A08868Lenovo ThinkSystem NE2552E Flex Switch2400FM514Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch24**00FM510Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch24**00FE327Lenovo Flex System SI4091 10Gb System Interconnect Module2200FM518Lenovo Flex System Fabric SI4093 System Interconnect Module24**90Y9346Flex System EN6131 40Gb Ethernet Switch2288Y6043Flex System EN4091 10Gb Ethernet Pass-thru2249Y4294Flex System EN2092 1Gb Ethernet Scalable Switch24**94Y5350Cisco Nexus B22 Fabric Extender for Flex System2200D5823*Flex System Fabric CN4093 10Gb Converged Scalable Switch24**95Y3309*Flex System Fabric EN4093R 10Gb Scalable Switch24**49Y4270*Flex System Fabric EN4093 10Gb Scalable Switch24**95Y3313*Flex System Fabric SI4093 System Interconnect Module24**94Y5212*Flex System EN4023 10Gb Scalable Switch24*** Withdrawn from marketing† This is the number of adapter ports that will be enabled per adapter, and requires that two switches be installed in the chassis.** The use of 4 ports will require either a switch upgrade to enable additional ports or the use of Flexible Port Mapping to reconfigure the active portsThe following table shows the connections between adapters installed in the compute nodes and the switch bays in the chassis.Table 4. Adapter to I/O bay correspondenceI/O adapter slot in the server Port on the adapter Corresponding I/O module bayin the chassisSlot 1Port 1Module bay 1Port 2Module bay 2Port 3*Module bay 1Port 4*Module bay 2 Slot 2Port 1Module bay 3Port 2Module bay 4Port 3*Module bay 3Port 4*Module bay 4Slot 3(full-wide compute nodes only)Port 1Module bay 1 Port 2Module bay 2 Port 3*Module bay 1 Port 4*Module bay 2Slot 4(full-wide compute nodes only)Port 1Module bay 3 Port 2Module bay 4 Port 3*Module bay 3 Port 4*Module bay 4* Ports 3 and 4 (CN4054S only) require Upgrade 1 of the selected switch, where applicable. 14-port modules such as the EN4091 Pass-thru, SI4091 switch, and Cisco B22 only support ports 1 and 2 (and only when two I/O modules are installed).The following figure shows the internal layout of the CN4054S, with how the adapter ports are routed to the I/O module internal ports.Note: INTD1 is not available on any currently shipping Flex System I/O modules.Figure 2. Internal layout of the CN4054S adapter portsThe following figure shows the internal layout of the CN4052S, and how the adapter ports are routed to the I/O module internal ports.Note: INTD1 is not available on any currently shipping Flex System I/O modules.Figure 3. Internal layout of the CN4052S adapter portsThe connections between the adapters installed in the compute nodes to the switch bays in the chassis are shown diagrammatically in the following figure. The figure shows half-wide servers (such as the x240 M5 with two adapters) and full-wide servers (such as the x440 with four adapters).Figure 4. Logical layout of the interconnects between I/O adapters and I/O modulesSUSE Linux Enterprise Server 12 SP2N N N Y Y Y Y Y SUSE Linux Enterprise Server 12 SP2 with Xen N N N Y Y Y Y Y SUSE Linux Enterprise Server 12 SP3N N N Y Y Y Y Y SUSE Linux Enterprise Server 12 SP3 with Xen N N N Y Y Y Y Y SUSE Linux Enterprise Server 12 SP4N Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP4 with Xen N Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP5Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP5 with Xen Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 15N Y Y Y Y Y Y N SUSE Linux Enterprise Server 15 SP1N Y Y Y Y Y Y N SUSE Linux Enterprise Server 15 SP1 with Xen N Y Y Y Y Y Y N SUSE Linux Enterprise Server 15 SP2Y Y Y Y Y Y Y N SUSE Linux Enterprise Server 15 SP2 with Xen Y Y Y Y Y Y Y N SUSE Linux Enterprise Server 15 SP3Y Y Y Y Y N N N SUSE Linux Enterprise Server 15 SP3 with Xen Y Y Y Y Y N N N SUSE Linux Enterprise Server 15 SP4Y Y Y Y Y N N N SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y N N N SUSE Linux Enterprise Server 15 SP5Y Y Y Y Y N N N SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y N N N SUSE Linux Enterprise Server 15 with Xen N Y Y Y Y Y Y N Ubuntu 18.04.5 LTSY N N N N N N N VMware vSphere Hypervisor (ESXi) 5.5N N N N N Y N Y VMware vSphere Hypervisor (ESXi) 6.0 U3N N N Y Y Y N Y VMware vSphere Hypervisor (ESXi) 6.5N N N Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.5 U1N N N Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.5 U2N Y Y Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.5 U3N Y Y Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.7N N N Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.7 U1N Y Y Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.7 U2N Y Y Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.7 U3Y Y Y Y Y Y N N VMware vSphere Hypervisor (ESXi) 7.0N Y Y Y Y N N N VMware vSphere Hypervisor (ESXi) 7.0 U1N Y Y Y Y N N N VMware vSphere Hypervisor (ESXi) 7.0 U2Y Y Y Y Y N N NOperating systemsS N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (719x 440 (7167)VMware vSphere Hypervisor (ESXi) 7.0 U3Y Y Y Y Y N N NOperating systemsTable 6. Operating system support for Flex System CN4054S 4-port 10Gb Virtual Fabric Adapter, 00AG590Operating systemsMicrosoft Windows Server 2012N N N N N Y Y Y N Y Y Y Microsoft Windows Server 2012 R2N N N Y Y Y Y Y N Y Y Y Microsoft Windows Server 2016Y Y Y Y Y Y N Y N Y Y N Microsoft Windows Server 2019Y Y Y Y Y N N Y N N N N Microsoft Windows Server 2022Y Y Y Y Y N N N N N N N Microsoft Windows Server version 1709N N N Y Y N N Y Y N Y N Microsoft Windows Server version 1803N N N Y N N N N N N N N Red Hat Enterprise Linux 6.10N N N Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 6.9N N N Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.3N N N Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.4N N N Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.5N N N Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.6N Y Y Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.7N Y Y Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.8N Y Y Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.9Y Y Y Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 8.0N Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.1N Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.2Y Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.3Y Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.4Y Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.5Y Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.6Y Y Y Y Y N N N N N N N Red Hat Enterprise Linux 8.7Y Y Y Y Y N N N N N N NS N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (719x 440 (7167)S N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 (8737, E 5 v 2)x 240 (7162)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (7196)x 280/x 480/x 880 X 6 (7903)x 440 (7167)x 440 (7917)SUSE Linux Enterprise Server 11 SP4N N N Y Y Y Y Y N Y Y Y SUSE Linux Enterprise Server 11 SP4 with Xen N N N Y Y Y Y Y N Y Y Y SUSE Linux Enterprise Server 11 for x86N N N N N N Y N N N Y N SUSE Linux Enterprise Server 12 SP2N N N Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP2 with Xen N N N Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP3N N N Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP3 with Xen N N N Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP4N Y Y Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP4 with Xen N Y Y Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP5Y Y Y Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP5 with Xen Y Y Y Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 15N Y Y Y Y N N Y Y N N N SUSE Linux Enterprise Server 15 SP1N Y Y Y Y N N Y Y N N N SUSE Linux Enterprise Server 15 SP1 with Xen N Y Y Y Y N N Y Y N N N SUSE Linux Enterprise Server 15 SP2Y Y Y Y Y N N Y Y N N N SUSE Linux Enterprise Server 15 SP2 with Xen Y Y Y Y Y N N Y Y N N N SUSE Linux Enterprise Server 15 SP3Y Y Y Y Y N N N N N N N SUSE Linux Enterprise Server 15 SP3 with Xen Y Y Y Y Y N N N N N N N SUSE Linux Enterprise Server 15 SP4Y Y Y Y Y N N N N N N N SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y N N N N N N N SUSE Linux Enterprise Server 15 SP5Y Y Y Y Y N N N N N N N SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y N N N N N N N SUSE Linux Enterprise Server 15 with Xen N Y Y Y Y N N Y Y N N N Ubuntu 18.04.5 LTSY N N N N N N N N N N N VMware vSphere Hypervisor (ESXi) 5.5N N N N N Y Y Y N Y Y Y VMware vSphere Hypervisor (ESXi) 6.0 U3N N N Y Y Y Y Y Y Y Y Y VMware vSphere Hypervisor (ESXi) 6.5N N N Y Y Y N Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.5 U1N N N Y Y Y N Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.5 U2N Y Y Y Y Y N Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.5 U3N Y Y Y Y Y N Y Y Y N N VMware vSphere Hypervisor (ESXi) 6.7N N N Y Y N N Y N N N N VMware vSphere Hypervisor (ESXi) 6.7 U1N Y Y Y Y N N Y N N N N VMware vSphere Hypervisor (ESXi) 6.7 U2N Y Y Y Y N N Y N N N N VMware vSphere Hypervisor (ESXi) 6.7 U3Y Y Y Y Y N N Y N N N NOperating systemsS N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 (8737, E 5 v 2)x 240 (7162)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (719x 280/x 480/x 880 X 6 (790x 440 (7167)x 440 (7917)VMware vSphere Hypervisor (ESXi) 7.0N Y Y Y Y N N N N N N N VMware vSphere Hypervisor (ESXi) 7.0 U1N Y Y Y Y N N N N N N N VMware vSphere Hypervisor (ESXi) 7.0 U2Y Y Y Y Y N N N N N N N VMware vSphere Hypervisor (ESXi) 7.0 U3Y Y Y Y Y N N N N N N NOperating systemsTable 7. Operating system support for Flex System CN4052S 2-port 10Gb Virtual Fabric Adapter Advanced,01CV780Operating systemsMicrosoft Windows Server 2012N N N N N Y Y Y Y Microsoft Windows Server 2012 R2N N N Y Y Y Y Y Y Microsoft Windows Server 2016Y Y Y Y Y Y Y Y N Microsoft Windows Server 2019Y Y Y Y Y Y N N N Microsoft Windows Server 2022Y Y Y Y Y N N N N Microsoft Windows Server version 1709N N N Y Y Y Y N N Microsoft Windows Server version 1803N N N Y N N N N N Red Hat Enterprise Linux 6.10N N N Y Y Y Y Y Y Red Hat Enterprise Linux 6.9N N N Y Y Y Y Y Y Red Hat Enterprise Linux 7.3N N N Y Y Y Y Y Y Red Hat Enterprise Linux 7.4N N N Y Y Y Y Y Y Red Hat Enterprise Linux 7.5N N N Y Y Y Y Y Y Red Hat Enterprise Linux 7.6N Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.7N Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.8N Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 7.9Y Y Y Y Y Y Y Y Y Red Hat Enterprise Linux 8.0N Y Y Y Y N N N N Red Hat Enterprise Linux 8.1N Y Y Y Y N N N N Red Hat Enterprise Linux 8.2Y Y Y Y Y N N N N Red Hat Enterprise Linux 8.3Y Y Y Y Y N N N NS N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 (8737, E 5 v 2)x 240 (7162)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (719x 280/x 480/x 880 X 6 (790x 440 (7167)x 440 (7917)S N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (7196)x 280/x 480/x 880 X 6 (7903)x 440 (7917)Red Hat Enterprise Linux 8.4Y Y Y Y Y N N N N Red Hat Enterprise Linux 8.5Y Y Y Y Y N N N N Red Hat Enterprise Linux 8.6Y Y Y Y Y N N N N Red Hat Enterprise Linux 8.7Y Y Y Y Y N N N N SUSE Linux Enterprise Server 11 SP4N N N Y Y Y Y Y Y SUSE Linux Enterprise Server 11 SP4 with Xen N N N Y Y Y Y Y Y SUSE Linux Enterprise Server 11 for x86N N N N N N Y N N SUSE Linux Enterprise Server 12 SP2N N N Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP2 with Xen N N N Y Y N Y Y Y SUSE Linux Enterprise Server 12 SP3N N N Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP3 with Xen N N N Y Y N Y Y Y SUSE Linux Enterprise Server 12 SP4N Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP4 with Xen N Y Y Y Y N Y Y Y SUSE Linux Enterprise Server 12 SP5Y Y Y Y Y Y Y Y Y SUSE Linux Enterprise Server 12 SP5 with Xen Y Y Y Y Y N Y Y Y SUSE Linux Enterprise Server 15N Y Y Y Y Y Y N N SUSE Linux Enterprise Server 15 SP1N Y Y Y Y Y Y N N SUSE Linux Enterprise Server 15 SP1 with Xen N Y Y Y Y Y Y N N SUSE Linux Enterprise Server 15 SP2Y Y Y Y Y Y Y N N SUSE Linux Enterprise Server 15 SP2 with Xen Y Y Y Y Y Y Y N N SUSE Linux Enterprise Server 15 SP3Y Y Y Y Y N N N N SUSE Linux Enterprise Server 15 SP3 with Xen Y Y Y Y Y N N N N SUSE Linux Enterprise Server 15 SP4Y Y Y Y Y N N N N SUSE Linux Enterprise Server 15 SP4 with Xen Y Y Y Y Y N N N N SUSE Linux Enterprise Server 15 SP5Y Y Y Y Y N N N N SUSE Linux Enterprise Server 15 SP5 with Xen Y Y Y Y Y N N N N SUSE Linux Enterprise Server 15 with Xen N Y Y Y Y Y Y N N Ubuntu 18.04.5 LTSY N N N N N N N N VMware vSphere Hypervisor (ESXi) 5.5N N N N N Y Y Y Y VMware vSphere Hypervisor (ESXi) 6.0 U3N N N Y Y Y Y Y Y VMware vSphere Hypervisor (ESXi) 6.5N N N Y Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.5 U1N N N Y Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.5 U2N Y Y Y Y Y Y Y N VMware vSphere Hypervisor (ESXi) 6.5 U3N Y Y Y Y Y Y Y NOperating systems S N 550 V 2S N 550 (X e o n G e n 2)S N 850 (X e o n G e n 2)S N 550 (X e o n G e n 1)S N 850 (X e o n G e n 1)x 240 M 5 (9532)x 280/x 480/x 880 X 6 (719x 280/x 480/x 880 X 6 (790x 440 (7917)TrademarksLenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web athttps:///us/en/legal/copytrade/.The following terms are trademarks of Lenovo in the United States, other countries, or both:Lenovo®Flex SystemServerProven®System x®ThinkSystem®VMready®XClarity®The following terms are trademarks of other companies:Xeon® is a trademark of Intel Corporation or its subsidiaries.Linux® is the trademark of Linus Torvalds in the U.S. and other countries.Microsoft®, Hyper-V®, SQL Server®, SharePoint®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.Emulex CN4052S and CN4054S 10Gb VFA5.2 Adapters for Flex System21。
【产品手册】FC系列光纤活动连接器和适配器
FC系列光纤活动连接器和适配器特点采用标准金属零件,互换性好陶瓷插针,PC、UPC、APC研磨光缆外径:Φ0.9、Φ2、Φ3适配器可采用分体和一体化金属外壳,陶瓷套筒,插入损耗小符合标准:YD/T826、YD/T896、IEC61754—13用途各类光纤通信网络光纤CATV光纤局域网仪表仪器产品技术特性外形尺寸FC型光纤插头FC型光纤适配器FC-A(分体适配器)FC-A-01(棱形适配器)FC-A-02(棱形适配器)FC-A-03(一体化薄形适配器)FC-A-04(厚板型形适配器)FC-A(H) (H型适配器)FC-A(H)-02 (小H型适配器)FC-A(D) (D型适配器)SC/DSC系列光纤活动连接器和适配器特点推拉式结构,轴向锁紧,连接快速、可靠标准塑料壳体,互换性好陶瓷插针,PC、UPC、APC研磨陶瓷套筒,插入损耗低光缆外径:Φ0.9、Φ2.0、Φ3.0单/双工连接器和适配器符合标准:YD/T895、IEC61754—4、IEC874—14、IEC874—1用途各类光纤通信网络光纤CATV光纤局域网产品技术特性外形尺寸SC型光纤插头DSC型光纤插头SC型光纤适配器 DSC型光纤适配器LC/DLC系列光纤活动连接器和适配器特点体积小(仅为SC的50%),重量轻,适合高密度安装标准塑料壳体,互换性好RJ-45推拉式锁紧结构,连接取卸快速、可靠单/双工连接器和适配器Φ1.25陶瓷插针,PC、UPC研磨光缆外径:Φ0.9、Φ2.0、Φ3.0符合标准:IEC61754—20、YD/T1272.1用途各类光纤通信网络新型同步终端设备和用户线路终端光纤到户、光纤到桌面DWDM系统ODF架产品技术特性外形尺寸LC型光纤插头DLC型光纤插头LC型光纤适配器 DLC型光纤适配器MU系列光纤活动连接器和适配器特点体积小(仅为SC的40%),重量轻,适合高密度安装标准塑料壳体,互换性好推拉式结构,轴向锁紧,连接快速、可靠Φ1.25陶瓷插针,PC、UPC研磨光缆外径:Φ0.9、Φ2.0符合标准:IEC61754—6、YD/T1200用途各类光纤通信网络光纤到户、光纤到桌面新型同步终端设备和用户线路终端DWDM系统ODF架产品技术特性外形尺寸MU型光纤插头 MU型光纤适配器ST系列光纤活动连接器及适配器特点标准金属零件,互换性好卡口式锁紧结构,连接快速、可靠陶瓷插针,PC和UPC研磨光缆外径:Φ0.9、Φ2.0、Φ3.0适配器采用一体化金属外壳陶瓷套筒,插入损耗低符合标准:YD/T987、IEC61754—2、IEC874—10用途各类光纤通信网络光纤局域网仪器仪表产品技术特性外形尺寸ST型光纤插头ST型光纤适配器MTRJ系列光纤活动连接器及适配器特点标准塑料壳体,互换性好RJ-45推拉式锁紧结构,连接取卸快速、可靠可同时接通2、4芯光纤,适合高密度安装光缆外径:Φ3集束缆、Φ3带状缆、Φ2并行缆、Φ0.9光纤符合标准:IEC61754—18、YD/T1272.2、TIA/EIA—604—12用途数据和通信系统光纤接入网光纤到户、光纤到桌面集成光电系统产品技术特性外形尺寸MTRJ型光纤插头(不带导针)MTRJ型光纤插头(带导针)MTRJ型光纤适配器DIN系列光纤活动连接器及转换器特点标准金属零件,互换性好陶瓷插针,PC、UPC研磨光缆外径:Φ0.9、Φ2.0、Φ3.0符合标准:IEC874-6用途各种光纤通信网络CATV光纤局域网仪器仪表产品技术特性外形尺寸DIN型光纤插头DIN型光纤适配器E2000系列光纤活动连接器和适配器E2000型系列光纤连接器是一种装有弹簧闸门的光纤连接器。
Emulex OCe14100B VFA5.2 适配器系列产品指南说明书
Emulex OCe14100B VFA5.2 Adapter FamilyProduct GuideThe Emulex Virtual Fabric Adapter 5 Generation 2 (VFA5.2) Network Adapter Family, which includes the OCe14104B-NX 10 GbE adapter builds on the foundation of the previous generation of Emulex VFA5 adapters by delivering performance enhancements, including RoCE v2 support and management enhancements with improved support for Lenovo XClarity. These new features help reduce complexity, reduce cost, and improve performance with Lenovo servers.The following figure shows the Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter.Figure 1. Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ AdapterDid you know?The Emulex VFA5.2 adapters support three methods to virtualize I/O, out of the box: Virtual Fabric Mode (vNIC1), Switch Independent mode (vNIC2) and Unified Fabric Port (UFP) mode. With Virtual Fabric, up to eight virtual network ports (vNICs) can be created with a single two-port 10 GbE network adapter.On System x adapters, storage protocols such as iSCSI and FCoE are also supported by Features on Demand upgrades. Using a common hardware infrastructure for Ethernet and SAN and by virtualizing your network adapter, you can reduce your infrastructure capital expense.Click here to check for updatesThe following table lists the supported fiber optic cables and Active Optical Cables. Table 3. Optical cablesPart number Feature code DescriptionLC-LC 0M3 Fiber Optic Cables (requires transceivers)00MN499ASR5Lenovo 0.5m LC-LC OM3 MMF Cable00MN502ASR6Lenovo 1m LC-LC OM3 MMF Cable00MN505ASR7Lenovo 3m LC-LC OM3 MMF Cable00MN508ASR8Lenovo 5m LC-LC OM3 MMF Cable00MN511ASR9Lenovo 10m LC-LC OM3 MMF Cable00MN514ASRA Lenovo 15m LC-LC OM3 MMF Cable00MN517ASRB Lenovo 25m LC-LC OM3 MMF Cable00MN520ASRC Lenovo 30m LC-LC OM3 MMF CableSFP28 25Gb Active Optical Cables7Z57A03541AV1F Lenovo 3m 25G SFP28 Active Optical Cable 7Z57A03542AV1G Lenovo 5m 25G SFP28 Active Optical Cable 7Z57A03543AV1H Lenovo 10m 25G SFP28 Active Optical Cable 7Z57A03544AV1J Lenovo 15m 25G SFP28 Active Optical Cable 7Z57A03545AV1K Lenovo 20m 25G SFP28 Active Optical CableThe following table lists the supported direct-attach copper (DAC) cables.Table 4. Copper cablesPart number Feature code DescriptionSFP+ Passive DAC Cables00D6288A3RG0.5m Passive DAC SFP+ Cable90Y9427A1PH1m Passive DAC SFP+ Cable00AY764A51N 1.5m Passive DAC SFP+ Cable00AY765A51P2m Passive DAC SFP+ Cable90Y9430A1PJ3m Passive DAC SFP+ Cable90Y9433A1PK5m Passive DAC SFP+ CableSFP+ Active DAC Cables00VX111AT2R Lenovo 1m Active DAC SFP+ Cables00VX114AT2S Lenovo 3m Active DAC SFP+ Cables00VX117AT2T Lenovo 5m Active DAC SFP+ CablesSFP28 25Gb Passive DAC Cables7Z57A03557AV1W Lenovo 1m Passive 25G SFP28 DAC Cable 7Z57A03558AV1X Lenovo 3m Passive 25G SFP28 DAC Cable 7Z57A03559AV1Y Lenovo 5m Passive 25G SFP28 DAC CableFigure 2. Emulex VFA5.2 2x10 GbE SFP+ PCIe AdapterFeaturesThe VFA5.2 adapters offer virtualized networking, support a converged infrastructure, and improve performance with powerful offload engines. The adapter has the following features and benefits. Reduce complexityVirtual NIC emulationThe Emulex VFA5.2 supports three NIC virtualization modes right out of the box: Virtual Fabricmode (vNIC1), switch independent mode (vNIC2), and Unified Fabric Port (UFP). With NICvirtualization, each of the two physical ports on the adapter can be logically configured to emulate up to four virtual NIC (vNIC) functions with user-definable bandwidth settings. Additionally, each physical port can simultaneously support a storage protocol (FCoE or iSCSI).Common drivers and toolsYou can deploy faster and manage less when you use both Virtual Fabric Adapters (VFAs) and Host Bus Adapters (HBAs) that are developed by Emulex. VFAs and HBAs developed by Emulex use the same installation and configuration process, streamlining the effort to get your server configuredFigure 3. ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet AdapterServer support - System xThe Emulex VFA5.2 adapter family is supported in the System x servers that are listed in the following tables.Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processorsTable 6. Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processorsPartnumber Description00AG570Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter Y Y Y Y Y Y N 00AG580Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW N N Y Y Y Y N 00AG560Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter N N Y Y Y Y N 01CV770Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSISWN N Y Y Y Y N7ZT7A00493ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+Ethernet AdapterN N N N N N N Support for servers with Intel Xeon v3 processorsTable 3. Support for servers with Intel Xeon v3 processorsPartnumber Description00AG570Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter N N Y Y Y Y Y 00AG580Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW N N Y Y Y Y Y 00AG560Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter N N N Y Y Y Y 01CV770Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSISWN N N N N Y Y7ZT7A00493ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter N N N N N N N x325M6(3943)x325M6(3633)x355M5(8869)x365M5(8871)x385X6/x395X6(6241,E7v4)nx36M5(5465,E5-26v4)sd35(5493) x31M5(5457)x325M5(5458)x35M5(5464)x355M5(5463)x365M5(5462)x385X6/x395X6(6241,E7v3)nx36M5(5465)TrademarksLenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web athttps:///us/en/legal/copytrade/.The following terms are trademarks of Lenovo in the United States, other countries, or both:Lenovo XClarityLenovo®RackSwitchServerProven®System x®ThinkSystemVMready®vNICThe following terms are trademarks of other companies:Intel® and Xeon® are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.Linux® is a trademark of Linus Torvalds in the United States, other countries, or both.Hyper-V®, Microsoft®, SQL Server®, SharePoint®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.。
Canon佳能卡口适配器EF-EOS M使用说明书中文版
卡口适配器EF-EOS M使用说明书CHI部件名称① 镜头释放杆② EF-S镜头安装标记③ EF镜头安装标记④ 相机镜头安装标记⑤ 触点(相机端)⑥ 触点(镜头端)⑦ 三角架座槽⑧ 三角架座螺丝⑨ 三角架座旋钮⑩ 三角架槽⑪ 证书/规章标志感谢您购买佳能产品!佳能镜头卡口适配器EF-EOS M的设计可将EF系列镜头*1与EF-M镜头兼容的可换镜头数码相机*2搭配使用。
在使用此适配器之前,请确保相机与镜头兼容。
使用本镜头前,请详细阅读使用手册,使您对镜头更熟悉并掌握正确的操作方法。
请务必妥善保管好本书,以便日后能随时查阅。
如果遇到不能解决的问题,请联系随机附送顾客联络表上列印的服务中心。
*1 不包含EF-M镜头或CN-E镜头(EF电影镜头)。
*2 仅下列相机与EF-M镜头兼容(2012年7月现在):EOS M1. 使用此适配器时的注意事项z z将此适配器连接至镜头并不会影响镜头的性能。
z z请使用镜头上的开关来设置镜头功能。
如果相机菜单中的设置与镜头上的设置不同,则应以镜头上的设置为准。
z z当您使用的镜头比相机还要重时,在移动相机及进行拍摄时请务必握住镜头。
z z由于镜头的最小对焦距离在连接此适配器时将会增加,因此最大放大倍率和视野范围可能会改变。
2. 安装和拆卸适配器安装程序1. 将EF镜头安装到EF适配器上的安装槽。
•z将EF镜头上的安装标记(红色圆圈)对准适配器上的相同标记,然后以顺时针方向转动EF镜头直到听到喀一声为止。
(图❶)•z将EF-S镜头安装到适配器时,请对准EF-S安装标记(白色方块)将镜头插入适配器,然后以顺时针方向转动。
(图❶)2. 将适配器安装到相机。
•z将适配器上的EF-M镜头安装标记(白色圆圈)对准相机上的相同标记将适配器装入相机,然后以逆时针方向转动适配器直到听到喀一声为止。
(图❷)CT1-7620-000初版:2012.60612Niz。
DTX-1800多模DTX-EFM2光纤测试报告
:
: 2000MHz-km (850 nm) : 2000MHz-km (1300 nm)
: 2 : 0 OM3 Multimode 50 (m): 1.0 (m): 1.0 (m): 0.3 11/20/2014 11:17:54
(R->M)
: 11/20/2014 11:26:38 : GB 50312-2007 OF-300 Ch : 1.9300 : Your Name DTX-1800 (2345013 v2.7400) : DTX-EFM2(2345013) /
LinkWare
9.0
: DEFAULT 201411250.flw
: Client Name
: G9-H02
/ : 11/20/2014 11:23:58 : OM3 Multimode 50 n = 0.0000 (850 nm) n = 1.4835 (1300 nm)
850 nm (dB) (dB) (dB) (dBm) 0.27 2.55 2.28 -23.53 : 1 2 3 :
:
: 2000MHz-km (850 nm) : 2000MHz-km (1300 nm)
: 2 : 0 OM3 Multimode 50 (m): 1.0 (m): 1.0 (m): 0.3 11/20/2014 11:17:54
(R->M)
: 11/20/2014 11:23:58 : GB 50312-2007 OF-300 Ch : 1.9300 : Your Name DTX-1800 (2345013 v2.7400) : DTX-EFM2(2345013) /
LinkWare
9.0
: DEFAULT 201411250.flw
Emulex LightPulse 适配器用户指南说明书
Documentation for Emulex® LightPulse® Adapters User GuideVersion 11.4September 11, 2017Documentation for Emulex LightPulse Adapters User GuideSeptember 11, 2017Corporate Headquarters WebsiteSan Jose, CA Broadcom, the pulse logo, Connecting everything, Avago Technologies, Avago, the A logo, Emulex, ExpressLane,LightPulse, and OneCommand are among the trademarks of Broadcom in the United States, certain other countriesand/or the EU.Copyright © 2003-2017 Broadcom. All Rights Reserved.The term “Broadcom” refers to Broadcom Limited and/or its subsidiaries. For more information, please visit.Broadcom reserves the right to make changes without further notice to any products or data herein to improvereliability, function, or design.Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does not assume anyliability arising out of the application or use of this information, nor the application or use of any product or circuitdescribed herein, neither does it convey any license under its patent rights nor the rights of others.Table of ContentsDocumentation for Emulex LightPulse Adapters User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Emulex Software Kit Migration User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.1 Supported Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.2 Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211.2.1 Inbox Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.2.2 Management Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.2.3 Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.3 Driver Kit Designations and Application Kit Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221.4 Additional Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Chapter 2: Installing Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.1 Installing Split Out-of-Box Drivers over Inbox Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.1.1 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.1.2 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242.1.3 VMware Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262.2 Installing Split Out-of-Box Drivers over Existing 11.1 or Earlier Out-of-Box Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.2.1 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282.2.2 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292.2.3 VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312.2.4 Solaris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Chapter 3: Reverting Drivers and Applications to Previous Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.1 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363.2 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383.3 VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423.4 Solaris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Chapter 4: Technical Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.1.1 LightPulse-Specific or OneConnect-Specific Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.1.2 Multiple ASICs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.1.3 Reverting to a Prior Driver Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 484.1.4 Boot Code Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.2 Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.2.1 Windows OneInstall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.2.2 Downgrading from a LightPulse 11.2 Kit with LPe16000-series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.2.3 Downgrading from a LightPulse 11.2 Kit to a 11.0 Kit with LPe12000-Series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.3 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.3.1 Unloading the lpfc and the brcmfcoe Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.3.2 Installing a pre-11.2 Version of OneCommand Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.4 VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514.4.1 VMware Inbox Driver Installation over 11.2 Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514.5 Solaris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 524.5.1 Running the Install Script of a pre-11.2 Kit Does Not Uninstall the Broadcom OneCommand CNA Manager . . . . . . . . . . . . . . . . . . . . . 524.6 Dell Applications Downgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Appendix A: Driver Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Appendix B: Quick Lookup Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55B.1 Quick Lookup Guide, LightPulse and OneConnect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55B.1.1 LightPulse Adapters and Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56C.1 Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68C.2 VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 Emulex OneCommand Manager Application for LightPulse Adapters User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 751.1 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Chapter 2: Installing and Uninstalling OneCommand Manager Application Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782.1 Installing the OneCommand Manager Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782.1.1 In Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 782.1.2 In Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 802.1.3 In Solaris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 822.1.4 In VMware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 842.2 Uninstalling the OneCommand Manager Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Chapter 3: Starting and Stopping the OneCommand Manager Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 853.1 In Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 853.2 In Linux and Solaris . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Chapter 4: Using the OneCommand Manager Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874.1 The OneCommand Manager Application Window Element Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 874.1.1 Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 884.1.2 Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 884.1.3 Discovery-Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 894.1.4 Property Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.1.5 Status Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 914.2 Using OneCommand Manager Secure Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 924.2.1 OneCommand Manager Secure Management Configuration Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 934.3 Changing Management and Read-Only Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 934.3.1 Management Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 944.4 Using CIM (Windows Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Chapter 5: Configuring Discovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 965.1 Discovery Using the TCP/IP Access Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 965.1.1 Hosts File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 975.1.2 Adding a Single Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 985.1.3 Adding a Range of Hosts (IPv4 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 995.1.4 Removing Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1005.2 Configuring Discovery and Default CIM Credentials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1015.3 Viewing Discovery Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Chapter 6: Managing Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1046.1 Viewing Host Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1046.1.1 Function Summary Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1056.2 Viewing Host Grouping Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1056.3 Grouping Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1066.3.1 Managing Host Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1076.3.2 Creating a Host Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1086.3.3 Deleting a Host Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1086.3.4 Adding a Host to a Host Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1096.3.5 Removing a Host from a Host Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1096.3.6 Restoring a Host Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1096.3.7 Restoring All Host Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1096.3.8 Exporting Host Grouping Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1096.4 Searching for Hosts in the Discovery-Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1107.1 FC Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1117.1.1 Viewing FC Adapter Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1117.1.2 Viewing FC Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1127.1.3 Viewing FC Firmware Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1137.2 LPe16202/OCe15100 Adapters in NIC+FCoE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1167.2.1 Viewing LPe16202/OCe15100 Adapter Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1167.2.2 Viewing Firmware Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1187.2.3 Viewing Physical Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1197.2.4 Viewing Transceiver Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Chapter 8: Managing Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1238.1 FC and FCoE Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1238.1.1 Viewing FCoE Function Information (LPe16202/OCe15100 Adapters) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1238.1.2 Viewing and Clearing FC and FCoE Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1248.1.3 Viewing FC and FCoE Virtual Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1268.1.4 Creating and Deleting FC and FCoE Virtual Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1278.1.5 Viewing FC and FCoE Fabric Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1318.1.6 Viewing FC Port Transceiver Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1328.1.7 Viewing FC and FCoE VPD Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1338.1.8 Viewing FC Maintenance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1348.1.9 Viewing FCoE Maintenance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1368.1.10 Viewing FC or FCoE Target Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1378.1.11 Viewing FC or FCoE LUN Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1388.1.12 Viewing FC and FCoE Target Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1408.1.13 Using Automapping and Persistent Binding (Windows Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1428.1.14 Masking and Unmasking LUNs (Windows) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1458.1.15 Managing ExpressLane LUNs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1468.1.16 Changing the FC and FCoE WWPN and WWNN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1498.1.17 Changing the FC and FCoE Port Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1528.1.18 Resetting the FC and FCoE Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1528.1.19 Configuring the FC and FCoE Driver Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1538.1.20 Creating a Batch Mode Driver Parameters File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1598.1.21 Configuring FIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1618.1.22 Configuring Boot from an FC or FCoE SAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1628.1.23 Configuring Advanced Settings (Boot from SAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1668.1.24 Using FC-SP DHCHAP Authentication (Windows and Solaris) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1698.2 NIC Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1728.2.1 Viewing NIC Function Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1738.2.2 Viewing NIC VPD Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1748.2.3 Guest Operating System Discovery and Management from the Base Host Operating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1768.2.4 Viewing NIC PCI Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 Chapter 9: Updating Adapter Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1799.1 Updating Firmware for a Single Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1799.2 Updating Firmware for Multiple Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 Chapter 10: DCB Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Chapter 11: Exporting SAN Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18711.1 Creating a SAN Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Chapter 12: Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18812.1 FC Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18812.1.1 Viewing Flash Contents, PCI Registers, and Wakeup Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18812.1.2 Running a Quick Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19012.1.3 Running a POST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19012.1.4 Using Beaconing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190。
适配器的作用
适配器的作用
适配器的作用是在不同的系统、设备或接口之间提供兼容性和连接性,使它们能够正常地进行通信和交互。
具体来说,适配器可以实现以下功能:
1. 接口转换:当两个系统或设备使用不同的接口标准时,适配器可以将一个接口转换为另一个接口。
例如,将USB接口转换为HDMI接口。
2. 电源适配:适配器可以将不同电源标准的设备连接到不同地区的电源插座上。
例如,将220V电源转换为110V电源。
3. 协议转换:适配器可以处理不同设备之间使用的不同通信协议。
例如,将以太网协议转换为串口协议。
4. 数据转换:适配器可以将不同数据格式的信息转换为另一种格式,以便不同系统能够正确地解析和处理数据。
例如,将XML格式的数据转换为JSON格式。
5. 功能补充:适配器可以为某些设备添加附加功能,使其能够完成特定任务。
例如,为电视机添加无线网络功能。
总之,适配器的作用是解决不同系统、设备或接口之间的兼容性问题,实现它们之间的连接和交互。
通过适配器,我们可以方便地使用不同设备和系统,而不需要担心其不兼容的问题。
支持SFP的FLEX 5000 EtherNet IP适配器说明书
安装说明支持 SFP 的 FLEX 5000 EtherNet/IP 适配器产品目录号 5094-AENSFPR 、5094-AENSFPRXT 、5094-AEN2SFPR 、5094-AEN2SFPRXT产品概述支持 SFP 的 FLEX 5000™ I/O EtherNet/IP™ 适配器执行以下功能:•通过两个 SFP 插槽支持光口或电口小型可插拔 (SFP) 模块(1)。
•有助于在 FLEX 5000 I/O 模块与 Logix 5000™ 控制器之间通过 EtherNet/IP 网络实现高速数据传送。
•为 FLEX 5000 I/O 模块提供系统侧电源。
•5094-AENSFPR 和 5094-AENSFPRXT 适配器支持多达 8 个 FLEX 5000 I/O 模块。
•5094-AEN2SFPR 和 5094-AEN2SFPRXT 适配器支持多达 16 个 FLEX 5000 I/O 模块。
这些适配器是通过 Studio 5000 Logix Designer® 应用程序进行配置的。
有关如何使用支持 SFP 的 FLEX 5000 EtherNet/IP 适配器(包括兼容的 Logix 5000 控制器和 Logix Designer 应用程序版本)的更多信息,请参见第15页的其他资源中列出的出版物。
主题 页码关于适配器5准备事宜5适配器尺寸6设置网络 Internet 协议 (IP) 地址7将适配器安装到 DIN 导轨上8安装 SFP 模块9将电源连接到适配器9将适配器连接到 EtherNet/IP 网络11安装终端盖12为系统供电13拆除或更换适配器13技术参数14其他资源15(1)必须单独购买 SFP 模块。
有关支持的 SFP 模块列表,请参见第15页的支持的 SFP 模块。
有关 SFP 模块规格的信息,请参见 Stratix® Ethernet Device Specifications Technical Data ,出版号 1783-TD001。
EF-BOA01和EF-BOA02的RJ45断路器适配器说明说明书
EF-BOA01 (1 port) & EF-BOA02 (4 port)RJ45 Break out adaptorsThe EF-BOA01 is a DIN Rail mount RJ45 cable Break Out Adaptor, which has many uses in providing connections from non- RJ45 installation wiring to the EFDAU2000, and to similar equipment with RJ45 connections.Primary applications of the EF-BOA01Break out all of the connections from one RJ45 port, to eight screw terminals.Break out of the two Audio Input connections from each of four EFDAU2000 Audio Input Ports, where the additional data and power connections of the EFDAU2000 Audio Input ports are not required.Partial break-out of some RJ45 connections, using the daisy chain in-out RJ45 connectors with some signals wired out from the break out terminals and others being passed through on the RJ45 links.Termination of heavy duty Fire Proof Emergency Microphone installation cables to RJ45 patch leads, in order to enable connection to an EFDAU2000, or similar equipment.Termination of installation cables which require End of Line Monitoring Resistors to RJ45 patch leads, in order toenable connection to an EFDAU2000, or similar equipment.Connection of equipment which requires a separate DC power supply to an EFDAU2000 , or similar equipment.Break out adaptor optionsWe have two Break Out Adaptors which are suitable for use with the EFDAU2000, the EF-BOA01, and a simpler four way direct through connection adaptor, the EF-BOA02.Features and benefits• Din rail mount.• Flexible connection and usage.•Break out of all the connections from one RJ45 port, to eight screw terminals plus screen terminals.•Daisy-chain In-Out RJ45 connectors formultiple break outs and by-pass connections.• End of line monitoring resistor positions.•Additional dual redundant power inputs and output power terminals.•Additional screen connection and output cable screen terminals.EatonEMEA Headquarters Route de la Longeraie 71110 Morges, Switzerland Eaton.eu© 2018 EatonAll Rights ReservedPublication No. TD-EN-450-0418/CSSC-1168July 2018, Version 1Eaton is a registered trademark.All other trademarks are property of their respective owners.RJ45 Connectivity• Main Connection Port.•All four pairs of RJ45 signals taken to individual I/O Signal Terminal Pairs.•The connector screen is taken to the appropriate screen terminal.• Bypass Connection Port.•Straight through one to one connections from the Main Connection Port.• EFDAU2000 Audio Input Connection Ports.•Ports are each connected to a pair of input terminalsI/O T ermin al Con n ectivity•Lower Row of I/O Terminals8 Signal Terminals in four pairs, one pair for each twisted pair in the RJ45 cable • Connections to the RJ45 Ports•Upper Row of I/O Terminals 8 output power and output cable screen terminals•Two +24V output terminals, two 0V terminals, four cable screen terminals•Power Input Terminals (two pairs of three terminals each)End of line Resistor Positions• End of Line resistor positions (4 positions).• One resistor position across each pair of digital input.•Used for Fire Panel connection supervision.DimensionsH (mm)W (mm)D (mm)WeightOverall Dimensions 338852/0.1 kg 0.1 kgThe RJ45 cables will overhang the side of the EF-BOA,adding approximately 50mm to the effective widthEnvironmentalTemperature -20°C to +50°C (storage and operation)Humidity Range0% to 93% non-condensingSpecificationEaton order codesFurther informationPlease refer to the EFDAU2000 Manual 25-14401-A for further details.EFDAU2000 1 x Wall mount voice alarm system with capacity for up to 10 amplifier cards EF-DAU2000-DIN-KIT Expansion DIN rail and mounting kit EF-BOA01RJ45 Break Out Adaptor (single port)EF-BOA02RJ45 Break Out Adaptor (four ports)。
FC光纤适配器
FC光纤适配器一.简介FC光纤适配器属于光纤适配器(又名法兰盘)的范畴,也叫光纤连接器,是光纤活动连接器对中连接部件。
FC代表Fiber CONNECtor。
二.主要特性:光纤之间是由适配器通过其内部的开口套管连接起来的,以保证光纤跳线之间的最高连接性能。
为了固定在各种面板上,还设计了多种精细的固定法兰。
三.FC光纤适配器的描述FC适配器采用金属结构,螺旋式连接的高精度连接装置。
采用精密陶瓷或铜套筒,以确保长期稳定的机械性能和光学性能,方形、D型、矩形可供选择。
D型结构便于安装到面板上,螺旋式连接确保光信号稳定,可靠。
四.PC,UPC,APC在适配器中的定义FC适配器:PC是黑色,UPC是红色,APC是绿色,这个定义是指产品防尘帽的颜色。
FC接头是金属接头,一般在ODF侧采用,金属接头的可插拔次数比塑料要多。
五.主要性能1、用高精度的二氧化锆陶瓷插芯,性能可靠;2、配器有FC、SC、ST等型号;3、插入损耗:≤0.3dB ;4、回波损耗:PC≥40dB、UPC≥50dB、APC≥60dB;5、各项试验插入损耗变化值:互换性试验:≤0.2dB振动试验:≤0.1dB(10-60Hz,1.5mm振幅)抗拉强度试验:≤0.1dB(0-15Hg拉力,φ0.9mm光纤除外)高温试验:≤0.2dB(+85℃,持续100小时)低温试验:≤0.2dB(-40℃,持续100小时)温度循环试验:≤0.2dB(-40℃~+85℃,循环5次后)湿度试验:≤0.2dB(+25℃~+65℃,相对湿度93%,100小时后六.应用范围适用于通信网络,光纤CATV设备,计算机网络接口。
连接器的品种信号较多,除了上面介绍的三种外,还有MTRJ、ST、MU等,具体的外观参见下图。
”后面表明光纤接头截面工艺,即研磨方式。
“PC”在电信运营商的设备中应用得最为广泛,其接头截面是平的。
“UPC”的衰耗比“PC”要小,一般用于有特殊需求的设备,一些国外厂家ODF架内部跳纤用的就是FC/UPC,主要是为提高ODF设备自身的指标。
多模EF测试模块VIVIA
多模EF测试模块VIVIA
多模SFP
几乎所有的多模光纤尺寸均为50/125µm或62.5/125µm
并且带宽(光纤的信息传输量)通常为200MHz到2GHz。
多模光端机通过多模光纤可进行长达5公里的传输。
以发光二极管或激光器为光源。
拉环或者体外颜色为黑色。
单模SFP
单模光纤的尺寸为9-10/125µm,并且较之多模光纤具有无限量带宽和更低损耗的特性。
而单模光端机多用于长距离传输,有时可达到150至200公里。
采用LD或光谱线较窄的LED作为光源。
拉环或者体外颜色为蓝色、黄色或者紫色。
3
以下是了解到的一些单模和多模SFP的概念和区别。
区别一:
按照波长分
850nm/1310nm/1550nm/1490nm/1530nm/1610nm, 波长为850nm为SFP多模,传输距离在2Km以下,波长是1310/1550nm的为单模,传输距离在2Km以上,相对来说这三种波长的价格较其他三种
要便宜。
区别二:
裸模块如果没有标识很容易混淆,一般厂家会在拉环的颜色上进行区分,比如:
黑色拉环的为多模,波长是850nm;蓝色是波长1310nm的模块;黄色或者绿色则是波长1550nm的模块;紫色是波长1490nm的模块等。
区别三:
单模光纤价格便宜,但单模设备较之同类的多模设备却昂贵很多。
单模设备通常既可在单模光纤上运行,亦可在多模光纤上运行,而多模设备只限于在多模光纤上运行。
总结:
随着近年来单模与多模SFP光模块的拉近,目前单模光缆与单模模块的采用已经成为主流。
单模在使用上明显优于多模类型。
光模块 环通量ef
光模块环通量ef光模块是一种将光信号转换为电信号或将电信号转换为光信号的装置。
在光通信中,光模块扮演着重要的角色,其中环通量ef是光模块的一个重要性能指标。
环通量ef是指光模块中光纤中的光束在传输过程中的能量损耗。
光模块中的光纤是将光信号从发送端传输到接收端的媒介,而环通量ef则反映了在这个过程中光信号的损耗程度。
通常来说,环通量ef 越小,表示光信号在传输过程中的损耗越小,光模块的性能越好。
环通量ef的大小与光模块中的多个因素有关。
首先是光纤的质量与损耗特性。
优质的光纤能够降低光信号的损耗,从而减小环通量ef 的值。
其次是光模块的设计与制造工艺。
光模块的设计需要考虑光纤的连接方式、光纤的长度、光纤的弯曲程度等因素,以减小光信号在光纤中的损耗。
制造工艺的优化也可以提高光模块的性能,进而降低环通量ef的大小。
环通量ef还与光源的功率和光耦合效率有关。
光源的功率越高,光信号在传输过程中的损耗就越小,从而环通量ef的值也较小。
而光耦合效率则是衡量光源与光纤之间能量传输效率的指标,光耦合效率越高,环通量ef的值也越小。
为了降低环通量ef的大小,光模块的设计与制造需要充分考虑上述因素,并采取相应的措施。
例如,可以选择优质的光纤材料,并采用优化的光纤连接方式和制造工艺。
同时,对光源的功率和光耦合效率进行优化调节,以提高光模块的性能和降低环通量ef的值。
在实际应用中,环通量ef的大小对光模块的性能和光信号传输的质量都有重要影响。
较小的环通量ef值意味着光信号在传输过程中的损耗较小,从而可以实现更远距离的传输和更高的数据传输速率。
因此,提高光模块的性能,降低环通量ef的大小,对于光通信领域的发展具有重要意义。
环通量ef是光模块的重要性能指标之一,它反映了光信号在光纤传输中的损耗程度。
通过优化光纤质量、光模块设计与制造工艺、光源功率和光耦合效率等因素,可以降低环通量ef的大小,提高光模块的性能和传输质量。
光模块的不断发展和创新,将为光通信技术的进一步应用提供更广阔的空间。
适配器是什么
适配器是什么适配器是一种常见的设计模式,用于将一个类的接口转换成客户端所期望的另一种接口。
它允许不兼容的类能够一起工作,从而增加了软件系统的灵活性和可扩展性。
适配器模式在软件开发中扮演着重要的角色,被广泛应用于各种领域。
适配器模式是一种结构型设计模式,通过将一个类的接口包装成另一个所期望的接口,使得原本不兼容的类可以协同工作。
适配器模式主要涉及两个角色:目标接口和适配器。
目标接口是客户端所期望的接口,适配器通过实现目标接口,将对应的方法调用转发给被适配的对象。
适配器的作用就是建立目标接口与被适配对象之间的桥梁。
适配器模式可以应用于多种情况,包括以下几种常见的应用场景:1. 类适配器:通过继承适配器类与被适配类关联,实现目标接口的方法。
2. 对象适配器:通过关联适配器类与被适配类,实现目标接口的方法。
3. 接口适配器:当需要实现一个接口时,可以使用一个抽象类作为中间层,实现目标接口的方法,并提供默认的空方法。
适配器模式的优点是可以增强系统的灵活性和可扩展性,使得原本不兼容的类能够一起工作。
同时,它可以将改变封装在适配器中,对客户端代码无感知,提高了代码的可维护性和可读性。
除了上述优点,适配器模式还有一些局限性。
首先,适配器需要实现目标接口,并额外关联一个被适配的对象,这增加了系统的复杂性。
其次,适配器模式只能解决接口之间的兼容性问题,对于不兼容的类之间的适配需要其他的解决方案。
适配器模式在现实生活中有很多应用。
一个常见的例子是插座适配器。
不同国家或地区的插座标准可能不同,通过使用插座适配器,我们可以将不同类型的插头连接到同一个插座上,实现电器的正常运行。
另一个例子是音频适配器。
过去,CD机和MP3播放器都有自己的音频接口,为了连接这两种设备,我们可以使用一个适配器将MP3播放器的音频输出转换成CD机所需的音频输入。
适配器模式在软件开发中的应用也非常广泛。
例如,当我们需要使用一个第三方库或者组件,但其接口与我们的系统不兼容时,可以使用适配器模式将其包装成符合我们系统需求的接口。
光纤适配器规格书
光纤通信系统 光纤接入网 光纤数据传输 光纤 CATV 局域网(LAN) 测试设备
产品性能指标:
参数
单 位
插入损 耗
dB
互换性 dB
振动 dB
Hale Waihona Puke 工作温 度℃贮藏温 度
℃
FC适配器 PC UPC ≤≤ 0.01 0.01 ≤0.1 ≤0.2
-40~75
-45~85
APC ≤ 0.01
SC适配器 PC UPC ≤≤ 0.05 0.05 ≤0.1 ≤0.2
-40~75
-45~85
PC ≤ 0.05
ST适配器 PC UPC ≤≤ 0.01 0.01 ≤0.1 ≤0.2
出的光能量能最大限度地耦合到接收光纤中去,并使由于其介入光链路而对系
统 造 成 的 影 响 减 到 最 小 的 器 件 。在 一 定 程 度 上 ,光 纤 连 接 器 也 影 响 了 光 传 输 系
统的可靠性和各项性能。系列产品包括:FC. SC. ST. LC. MTRJ,广泛应用于 光纤配线架(ODF)、 光纤通信设备、 仪器等。 光纤适配器特性
光纤跳线产品 规格书
编制:__________ 审核:__________ 批准:__________
深圳市易飞扬通信技术有限公司
光纤适配器简介
概述: 光纤适配器(又名法兰盘),也叫光纤连接器,是光纤与光纤之间进行可拆卸
( 活 动 )连 接 的 器 件 。它 是 把 光 纤 的 两 个 端 面 精 密 对 接 起 来 ,以 使 发 射 光 纤 输
VS-30FW 火线800 1394b 适配器 网络集线器 说明书
火线800/1394b 适配器/集线器
火线800/1394b 适配器/网络集线器是一个三 端口IEEE 1394b 800Mbps (S800) 网络集线 器,它也支持传统的火线速度800Mbps, 400Mbps, 200Mbps, 以及 100Mbps (S800, S400, S200, S10ICATIONS
端口
3个 双向 IEEE 1394b 800Mbps (S800) 端口.
传输数据率 100/200/400/800Mbps (S100, S200, S400, S800).
标准
IEEE 1394−1995, IEEE P1394a, IEEE P1394b.
电源
12V DC, 500mA 或接自PC.
尺寸
12cm x 7.5cm x 2.5cm (4.7" x 2.95" x 0.98") 宽, 深, 高.
重量
约0.3kg
附件
电源,火线线缆,安装支架
可选配 RK−3T 19"机架适配器
FEATURES 端口 - 3 个双向 IEEE 1394b 800Mbps (S800). 距离 - 4.5m (14.75英尺) 至 9m (29.5英尺), 多台级联最多可达72m (236英尺). 热插拔 - 支持热插拔 传输数据率 - 100, 200, 400 以及 800Mbps. ESD防护 - 内建克莱黙 Spark-Guard Pro™ ESD保护电路 电源可轮换 - 可由12V DC供电,也可由PC供电 - 需要9-Pin FireWire® 800 线缆. 紧凑的克莱默工具型™ - 三个单元可以并排安装在一个1U的RK-3T适配机箱中
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
• 符合 IEC-61280-4-1 EF 标准和 IEC-14763-3 • 对各个光纤制造商的不同模态行为进行验证 • 可互换的坚固耐用的 SC、LC 和 ST 适配器 • 通过内置可视故障定位仪 (VFL) 执行故障排除 • 提高了测量的可重复性 • 减少了实验室仪器与现场仪器之间的插入损耗差异 新一代多模光纤适配器增加了符合所有标准的光纤认证测试功能ISO/IEC 和 TIA 最近采纳了环 形通量 (EF) 标准,它标准化了多模测试设备中使用的光源的发射条件。符合 EF规范的WireXpert 新款适配器可让您确保遵循 EF 标准 IEC 61280-4-1。
1Hale Waihona Puke