甲烷CH4探头
红外甲烷(CH4)传感器模块
产品的结构与特点◆NDIR 红外测量原理◆单光源、双光束◆数字信号处理◆温度自动补偿◆4-20mA/0.4-2V 、UART 、Modbus多种信号输出可选◆进口元器件,性能稳定,波动小◆长寿命,可自动零点校准◆多点标定,量程范围内线性良好◆可按用户要求订制气体种类、量程及精度等级圣凯安科技研发、生产的NE-101系列高精度红外气体传感器是一款采用NDIR红外吸收检测原理的气体传感器模组。
该传感器采用国外进口光源、特殊结构的光学腔体和双通道探测器,实现空间双光路参比补偿,微处理器进行信号采集、处理和输出,线性误差优于满量程的±1%、零点漂移小,具有很好的选择性,高灵敏度,无氧气依赖性,寿命长,低功耗;内置温度传感器,可进行温度补偿;同时具有4-20mA /0.4-2V、UART、Modbus (用户可选)输出;报警点可设置,能够简单、快速地与现有的监测和控制系统相连接,方便客户各种应用NDIR 红外气体检测模块NE-101NE Sensor检测气体SF6CO2CH4HC检测量程(其他量程请咨询技术人员)0-1000ppm0-2000ppm0-5000ppm0-5000ppm 0-1500ppm0-5000ppm0-1%VOL0-1%VOL 0-2000ppm0-1%VOL0-100LEL0-100LEL 0-3000ppm0-5%VOL0-10%VOL0-10%VOL分辨率1ppm;0.1%LEL(根据检测范围)进气方式管道式扩散式气体接口3mm(inner);5mm(outer)/气体流量0.2…0.5L/min(稳定)气室尺寸(L)76x(W)51x(H)22mm预热时间<2min;<30min(达到技术标准)运行电压9-36VDC输出波动0.5%FS输出信号4-20mA/0.4-2V、UART、Modbus(RTU、ASCLL、自定义)使用温度‐10℃—50℃温度对零点影响0.1%FS per℃存储温度‐20℃…60℃环境压力800hPa—1200hPa环境湿度0%…95%(rel.)响应时间<30s(@0.3l/min)<60s(@0.3l/min)检测下限2%FS重复性1%FS线性误差2%FS温度对满量程点影响0.2%FS per℃零点漂移1%FS/24h应用市场气体分析行业、工业过程控制、环境检测和发电厂、变电站进行气体浓度和气体泄漏检测报警安装说明该传感器安装定位孔间距64mm,孔径3mm接线插座间距2.54mm维修保养应注意的事项传感器应定期校准,建议不大于6个月,若开启自动校准长期运行则不需要校准;不要在粉尘密度大的环境长期使用传感器;请在传感器供电范围内使用传感器。
甲烷CH4气体检测仪
甲烷CH4气体检测仪甲烷CH4气体检测仪适用于各种环境和特殊环境中的甲烷CH4气体浓度和泄露,在线检测及现场声光报警,对危险现场的作业安全起到了预警作用,此仪器采用进口的电化学传感器和微控制器技术,具有信号稳定,精度高,重复性好等优点,防爆接线方式适用于各种危险场所,并兼容各种控制器,PLC,DCS等控制系统,可以同时实现现场报警和远程监控,报警功能,4-20mA标准信号输出,继电器开关量输出。
甲烷CH4气体检测仪产品特性:①进口电化学传感器具有良好的抗干扰性能,适用寿命8年。
②采用先进微处理技术,响应速度快,测量精度高,稳定性和重复性好。
③检测现场具有具有现场声光报警功能,气体浓度超标即时报警,是危险场所作业的安全保障。
4现场带背光大屏幕LCD显示,直观显示气体浓度,类型,单位,工作状态等。
5独立气室,更换传感器无须现场标定,传感器关键参数自动识别。
6全量程范围温度数字自动跟踪补偿,保证测量准确性。
甲烷CH4气体检测仪技术参数:检测气体:空气中的甲烷CH4检测范围:0~100ppm,0~200ppm,0~1000ppm,0~1000ppm,0~5000ppm,100%LEL可选。
分别率:0.01ppm(0~100ppm);0.1ppm(0~1000ppm);1ppm(0~10000ppm以上);0.1LEL.工作方式:固定式连续工作,扩散式,管道式,流通时,泵吸式可选。
检测误差:≦1%(F.S)响应时间:≦10S输出信号:电流信号输出4-20MA报警方式:2路无源节点信号输出,报警点可设置。
工作环境:-20℃~50℃(特殊要求:(-40℃~+70℃)相对湿度:≦90%RH工作电压:DC12~30V传感器寿命:3年防爆形式:探头变送器及传感器均为隔爆型。
防爆等级:Exd II CT6连接电缆:三芯电缆(单根线径≧1.5mm);建议选用屏蔽电缆。
连接距离:≦1000m.防护等级:IP65.外形尺寸:183X143X107mm.重量:1.5Kg.检测气体:空气中的甲烷CH4检测范围:0-100ppm、500ppm、1000ppm、5000ppm、0-100%LEL分辨率:0.1ppm、0.1%LEL显示方式:液晶显示温湿度:选配件,温度检测范围:-40~120℃,湿度检测范围:0-100%RH检测方式:扩散式、流通式、泵吸式可选安装方式:壁挂式、管道式检测精度:≤±3%线性误差:≤±1%响应时间:≤20秒(T90)零点漂移:≤±1%(F.S/年)恢复时间:≤20秒重复性:≤±1%信号输出:①4-20mA信号:标准的16位精度4-20mA输出芯片,传输距离1Km②RS485信号:采用标准MODBUS RTU协议,传输距离2Km③电压信号:0-5V、0-10V输出,可自行设置④脉冲信号:又称频率信号,频率范围可调(选配)⑤开关量信号:标配2组继电器,可选第三组继电器,继电器无源触点,容量220VAC3A/24VDC3A传输方式:①电缆传输:3芯、4芯电缆线,远距离传输(1-2公里)②GPRS传输:可内置GPRS模块,实时远程传输数据,不受距离限制(选配)接收设备:用户电脑、控制报警器、PLC、DCS、等报警方式:现场声光报警、外置报警器、远程控制器报警、电脑数据采集软件报警等报警设置:标准配置两级报警,可选三级报警;可设置报警方式:常规高低报警、区间控制报警电器接口:3/4″NPT内螺纹、1/2″NPT内螺纹,同时支持2种电器连接方式防爆标志:ExdII CT6(隔爆型)壳体材料:压铸铝+喷砂氧化/氟碳漆,防爆防腐蚀防护等级:IP66工作温度:-30~60℃工作电源:24VDC(12~30VDC)工作湿度:≤95%RH,无冷凝尺寸重量:183×143×107mm(L×W×H)1.5Kg(仪器净重)工作压力:0~100Kpa标准配件:说明书、合格证质保期:一年甲烷CH4气体检测仪的简单介绍:甲烷CH4报警器●自动温度补偿,零点,满量程漂移补偿●防高浓度气体冲击的自动保护功能●全软件校准功能,用户也可自行校准,用3个按键实现,操作简单●二线制4-20mA输出甲烷CH4气体检测仪的应用场所医药科研、制药生产车间、烟草公司、环境监测、学校科研、楼宇建设、消防报警、污水处理、工业气体过程控制石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、、锅炉房、垃圾处理厂、隧道施工、输油管道、加气站、地下燃气管道检修、室内空气质量检测、危险场所安全防护、航空航天、军用设备监测等。
甲烷传感器调校方法
甲烷传感器调校方法一、甲烷传感器每隔7天应按以下方法调校1.配备器材空气样,2%CH4校准气体、减压阀、气体流量计和橡胶软管。
2.调试程序(1) 空气样用橡胶软管连接传感器气室。
(2) 调校零点,范围控制在之内。
(3) 校准气瓶流量计出口用橡胶软管连接传感器气室。
(4) 打开气瓶阀门,先用小流量向传感器缓慢通入2%CH4校准气体,在显示值缓慢上升的过程中,观察报警值和断电值。
然后调节流量控制阀把流量调节到传感器说明书规定的流量(180mL),使其测量值稳定显示,持续时间大于90s。
使显示值与校准气浓度值一致。
若超差应更换传感器,预热后重新测试。
(5) 在通气的过程中,观察报警值、断电值是否符合要求,注意声、光报警和实际断电情况。
(6) 当显示值小于断电值时,测试复电功能。
3.填写调校记录,测试人员签字。
二、新甲烷传感器使用前、在用甲烷传感器大修后应按以下方法调校:1.配备仪器及器材催化燃烧式甲烷测定器检定装置、秒表、温度计、校准气(、、%CH4)、直流稳压电源、声级计、频率计、系统分站等。
2.调校程序(1)检查甲烷传感器外观是否完整,清理表面及气室积尘。
(2)甲烷传感器与稳压电源、频率计(或分站)连接,通电预热10min。
(3)在新鲜空气中调仪器零点,零值范围控制在之内。
(4)按说明书要求的气体流量,向气室通入%CH4校准气,调校甲烷传感器精度,使其显示值与校准气浓度值一致,反复调校,直至准确。
在基本误差测定过程中不得再次调校。
(5)基本误差测定。
按校准时的流量依次向气室通入、、%CH4校准气各约90s,每种气体分别通入三次,计算平均值,用平均值与标准值计算每点的基本误差。
(6)在每次通气的过程中同时要观察测量报警点、断电点、复电点和声、光报警情况。
以上内容也可以单独测量。
(7)声、光报警测试。
报警时报警灯应闪亮,声级计距蜂鸣器一米处,对正声源,测量声级强度。
(8)测量响应时间。
用秒表测量通入%CH4校准气,显示值从零升至最大显示值90%时的起止时间。
GJC4甲烷传感器说明书
GJC4矿用甲烷传感器使用说明书执行标准:GB3836-2010AQ 6203-2006Q/SW02-2015出版日期:2015/05/25陕西三为矿山安全设备有限公司目录1. 概述 (3)2. 产品特点 (3)3. 结构特征与工作原理 (4)4. 使用方法 (4)5. 维护及常见故障排除方法 (7)6. 贮存、运输、包装 (7)7. 注释 (8)8. 使用注意事项 (8)使用说明书警示:维修时不得改变本安电路和与本安电路有关的元器件的电气参数、规格和型号!本安关联产品不得随意改变配置!1. 概述GJC4矿用甲烷传感器(以下简称传感器)是集甲烷气体检测、声光报警、监测数据显示、通信为一体的低浓度甲烷传感器。
本传感器采用最新技术,采用冗余设计,提高了传感器的可靠性,并符合国家和煤炭工业有关行业标准《AQ 6203-2006 煤矿用低浓度载体催化式甲烷传感器》。
传感器外观:其正面为传感器的外形及LED显示器上部有固定传感器的提手、中间部安装有喇叭、下部有光报警玻璃罩、左上部为电源和通信电缆接口。
GJC4矿用甲烷传感器是为满足在易燃易爆场所对低浓度甲烷()的监测而设计的。
本传感器设计的防爆级别为本质安全。
产品符合相应的国家或行业标准。
满足特殊场所,如:煤矿的安全监控等需求。
传感器的基本电路结构如图1所示(按信号传递规则)。
GJC4矿用甲烷传感器采用微电子技术,吸收国内外众多甲烷传感器的特点,并在此基础上形成构造出独特的产品。
传感器采用通用微处理器和高精度A/D转换器,具有工作精度高、稳定可靠的特点,数据通信为一体。
减少了在构造监控系统时所需的设备类型,方便用户使用。
2. 产品特点传感器使用环境(工作条件)a 工作温度:0℃~+40℃;b 存储温度:-40℃~+60℃;c 相对湿度:<95%;d 气压:86kPa~110 KPa;使用地点无强烈腐蚀性气体,含有瓦斯或者煤尘的矿井下;无淋水、沁水、蒸汽的环境中。
甲烷传感器管理制度
甲烷传感器管理制度引言:甲烷(CH4)是一种常见的天然气,广泛应用于工业、家庭和能源领域。
然而,甲烷泄漏可能导致火灾、爆炸和环境污染。
为了及时探测和预防甲烷泄漏事故的发生,甲烷传感器的使用变得至关重要。
本文旨在建立一套完善的甲烷传感器管理制度,以确保设备的正常运行和安全使用。
一、甲烷传感器管理制度的制定目的甲烷传感器管理制度的主要目的是:1. 确保甲烷传感器设备的正常运行和可靠性;2. 预防甲烷泄漏事故的发生,保护人身和财产安全;3. 提高甲烷泄漏监测的效率和准确性。
二、甲烷传感器的选择和安装1. 甲烷传感器的选择应满足国家标准和相关法规的要求,并确保其性能和灵敏度可靠。
2. 甲烷传感器的安装位置应根据实际情况选择,一般应选择在可能泄漏的区域附近,以便及时检测到甲烷泄漏。
三、甲烷传感器的日常维护和检测1. 在正常使用情况下,甲烷传感器应每月进行一次维护和检测。
维护和检测的内容包括但不限于检查仪器外观是否完好,检查电源和连接线是否正常,以及检查传感器的灵敏度是否符合要求。
2. 甲烷传感器的维护和检测工作应由专业人员负责,并记录相关维护和检测数据。
四、甲烷传感器的故障处理1. 甲烷传感器出现故障时,应立即停止使用,并及时通知维修人员进行维修或更换。
2. 在维修或更换过程中,必须按照安全操作规程进行,确保维修人员和周围人员的安全。
五、甲烷传感器的培训和教育1. 所有使用甲烷传感器的人员必须经过相关培训和教育,并掌握甲烷泄漏的预防和处置知识。
2. 在培训和教育过程中,应强调甲烷泄漏事故的危害性和紧急处理方法,以增强员工的安全意识和应急能力。
六、甲烷传感器管理制度的监督和评估1. 甲烷传感器管理制度的实施过程需要进行监督和评估,以确保制度的有效性和合理性。
2. 监督和评估的方法可以包括定期抽查、内部审计和外部评估等。
七、甲烷传感器管理制度的完善和改进1. 根据使用过程中遇到的问题和经验总结,不断完善和改进甲烷传感器管理制度。
甲烷检测仪器工作原理
甲烷检测仪器工作原理
甲烷检测仪器的工作原理是基于气体的化学反应和光学测量的原理。
首先,甲烷检测仪器通常会使用一种称为甲烷传感器的气体传感器。
甲烷传感器通常采用金属氧化物半导体(Metal Oxide Semiconductor,简称MOS)作为敏感元件。
当甲烷气体通过传感器时,甲烷分子中的CH4会与传感器表面的氧气发生化学反应,导致传感器的电阻值发生变化。
这个电阻值的变化与甲烷气体的浓度成正比,因此可以通过测量电阻值的变化来确定甲烷气体的浓度。
其次,甲烷检测仪器还可以基于红外吸收光谱原理进行测量。
红外光谱法是一种常用的非侵入式测量方法,可以通过检测特定波长的红外光被样品中的分子吸收的程度来确定甲烷气体的浓度。
在甲烷检测仪器中,一束包含甲烷吸收特征波长的红外光通过气体样品,然后通过光学元件进行检测。
被吸收的光量与甲烷气体的浓度成正比,因此可以通过测量吸收光量的变化来确定甲烷气体的浓度。
综上所述,甲烷检测仪器的工作原理主要包括甲烷传感器的化学反应和红外吸收光谱的测量原理。
这些原理能够有效地检测甲烷气体的浓度,并广泛应用于甲烷泄漏检测、燃气检测等领域。
CH4甲烷传感器
CH4甲烷传感器CH4甲烷传感器特点:★是款内置微型气体泵的安全便携装置★整机体积小,重量轻,防水,防爆,防震设计.★高精度,高分辨率,响应迅速快.★采用大容量可充电锂电池,可长时间连续工作.★数字LCD背光显示,声光、振动报警功能.★上、下限报警值可任意设定,自带零点和目标点校准功能,内置温度补偿,维护方便.★宽量程,最大数值可显示到50000ppm、100.00%Vol、100%LEL.★数据恢复功能,免去误操作引起的后顾之忧.★显示值放大倍数可以设置,重启恢复正常.★外壳采用特殊材质及工艺,不易磨损,易清洁,长时间使用光亮如新.CH4甲烷传感器产品特性:★是款内置微型气体泵的高精度的手式安全便携装备;★进口电化学传感器具有良好的抗干扰性能,使用寿命长达3年;★采用先进微处理器技术,响应速度快,测量精度高,稳定性和重复性好;★检测现场具有现场声光报警功能,气体浓度超标即时报警,是危险现场作业的安全保障;★现场带背光大屏幕LCD显示,直观显示气体浓度/类型/单位/工作状态等;★全量程范围温度数字自动跟踪补偿,保证测量准确性;★半导体纳米工艺超低功耗32位微处量器;★全软件自动校准,传感器多达6级目标点校准功能,保证测量的准确性和线性,并且具有数据恢复功能;★全中文/英文操作菜单,简单实用,带温度补偿功能;★防高浓度气体冲击的自动保护功能;CH4甲烷传感器技术参数:检测气体:空气中的CH4甲烷气体检测范围:0-100ppm、500ppm、1000ppm、5000ppm、0-100%LEL分辨率:0.1ppm、0.1%LEL显示方式:液晶显示温湿度:选配件,温度检测范围:-40~120℃,湿度检测范围:0-100%RH检测方式:扩散式、流通式、泵吸式可选安装方式:壁挂式、管道式检测精度:≤±3%线性误差:≤±1%响应时间:≤20秒(T90)零点漂移:≤±1%(F.S/年)恢复时间:≤20秒重复性:≤±1%信号输出:①4-20mA信号:标准的16位精度4-20mA输出芯片,传输距离1Km②RS485信号:采用标准MODBUS RTU协议,传输距离2Km③电压信号:0-5V、0-10V输出,可自行设置④脉冲信号:又称频率信号,频率范围可调(选配)⑤开关量信号:标配2组继电器,可选第三组继电器,继电器无源触点,容量220VAC3A/24VDC3A传输方式:①电缆传输:3芯、4芯电缆线,远距离传输(1-2公里)②GPRS传输:可内置GPRS模块,实时远程传输数据,不受距离限制(选配)接收设备:用户电脑、控制报警器、PLC、DCS、等报警方式:现场声光报警、外置报警器、远程控制器报警、电脑数据采集软件报警等报警设置:标准配置两级报警,可选三级报警;可设置报警方式:常规高低报警、区间控制报警电器接口:3/4″NPT内螺纹、1/2″NPT内螺纹,同时支持2种电器连接方式防爆标志:ExdII CT6(隔爆型)壳体材料:压铸铝+喷砂氧化/氟碳漆,防爆防腐蚀防护等级:IP66工作温度:-30~60℃工作电源:24VDC(12~30VDC)工作湿度:≤95%RH,无冷凝尺寸重量:183×143×107mm(L×W×H)1.5Kg(仪器净重)工作压力:0~100Kpa标准配件:说明书、合格证质保期:一年CH4甲烷传感器简单介绍:CH4甲烷传感器报警器高精度、高分辨率,响应快速,超大容量锂电充电电池,采样距离远,LCD背光显示,声光报警功能,上、下限报警值可任意设定,可进行零点和任意目标点校准,操作简单,具有误操作数据恢复功能.CH4甲烷传感器应用场所:医药科研、学校科研、制药生产车间、烟草公司、环境检测、楼宇建设、消防报警、污水处理、石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、锅炉房、加气站、垃圾处理厂、隧道施工、输油管道、航空航天、工业气体过程控制、室内空气质量检测、地下燃气管道检修、危险场所安全防护、军用设备检测等。
煤矿甲烷传感器标校
甲烷传感器标校(1) 0 点标校:对传感器充入空气气样,使传感器当前数值降为0.00,用遥控器选择当前传感,一氧化碳:CO等),用遥控器上下键进入功能码 5,按器类型(比如甲烷:CH4两下遥控器的确认键会进入 0 点标校界面,将显示值调为 0.00后按下遥控器器确认键对传感器进行 0 点标校,传感器显示“ PASS” 说明 0 点标校完成(退出功能码 5 之后 1 分钟,传感器会上报标校结束标识)。
(2) 2.0%CH 4 点标校:0 点标校完成后按取消键,回到功能菜单选择界面,进入功能码 6,主机开始计时,此时进入标校状态,按确定键进入闪烁显示测量值界面,通入 2.0%CH4 气样,流量设置为250ml/min,当传感器显示值稳定 90 秒之后,调节显示值使其与通入的标准气体的甲烷浓度值一致,然后按下遥控器确认键对传感器进行标校,传感器显示“PASS” ,此时传感器显示值和气样值一致,且能稳定显示,然后关掉流量计阀门,拔掉气嘴,当前数值会慢慢下降,当数值降到报警值一下后,按 2 次“ 取消” 键,返回到传感正常显示测量值界面,标校完成(退出功能码 6 之后 1 分钟,传感器会上报标校结束标识)。
故障代码:Er01供电电压过低减少该传感器所在的电源分支所带传感器的数量,或更换线径更粗的电缆Er03 检测到异常突变数据出现该故障时,传感器的数码管会出现er03 和当前监测值交替闪烁,如果确认当前的监测值正常连续快速按三次遥控器确认键或软件操作解除突变故障;如果监测值异常需更换传感器Er04 采集模块故障打开传感器下壳体,检查催化组件是否有脱落情况或接触不良;重新安装后仍出现 er04 的更换催化组件Er05主机未校时需用遥控器或上位机给传感器校时Er06催化组件灵敏度太低或误标按照说明书进入传感器的功能菜单 6,重新标校;重新标校仍有故障 er06,需更换催化组件Er09 催化组件预热时间太短需要对催化组件重新进行预热Er10组件故障更换催化组件后重新标校。
GJC甲烷传感器说明书完整版
G J C甲烷传感器说明书集团标准化办公室:[VV986T-J682P28-JP266L8-68PNN]GJC4矿用甲烷传感器使用说明书执行标准:GB3836-2010AQ 6203-2006Q/SW02-2015出版日期:2015/05/25使用说明书警示:维修时不得改变本安电路和与本安电路有关的元器件的电气参数、规格和型号!本安关联产品不得随意改变配置!1. 概述GJC4矿用甲烷传感器(以下简称传感器)是集甲烷气体检测、声光报警、监测数据显示、通信为一体的低浓度甲烷传感器。
本传感器采用最新技术,采用冗余设计,提高了传感器的可靠性,并符合国家和煤炭工业有关行业标准《AQ 6203-2006 煤矿用低浓度载体催化式甲烷传感器》。
传感器外观:其正面为传感器的外形及LED显示器上部有固定传感器的提手、中间部安装有喇叭、下部有光报警玻璃罩、左上部为电源和通信电缆接口。
GJC4矿用甲烷传感器是为满足在易燃易爆场所对低浓度甲烷()的监测而设计的。
本传感器设计的防爆级别为本质安全。
产品符合相应的国家或行业标准。
满足特殊场所,如:煤矿的安全监控等需求。
传感器的基本电路结构如图1所示(按信号传递规则)。
GJC4矿用甲烷传感器采用微电子技术,吸收国内外众多甲烷传感器的特点,并在此基础上形成构造出独特的产品。
传感器采用通用微处理器和高精度A/D转换器,具有工作精度高、稳定可靠的特点,数据通信为一体。
减少了在构造监控系统时所需的设备类型,方便用户使用。
2. 产品特点传感器使用环境(工作条件)a 工作温度:0℃~+40℃;b 存储温度:-40℃~+60℃;c 相对湿度:<95%;d 气压:86kPa~110 KPa;使用地点无强烈腐蚀性气体,含有瓦斯或者煤尘的矿井下;无淋水、沁水、蒸汽的环境中。
检测范围甲烷检测范围:;电源(必须使用具有安全标志的矿用本质安全电源)工作电压:9V~24V DC(矿用本质安全电源);工作电流 < 100mA DC(18V DC)。
产品名称全量程甲烷传感器甲烷传感器高低浓度甲烷传感
产品名称:全量程甲烷传感器/甲烷传感器/高低浓度甲烷传感器(0-10%)产品型号:ZDZ-KJ101-45B全量程甲烷传感器/甲烷传感器/高低浓度甲烷传感器型号:ZDZ-KJ101-45B本产品是一种全新概念的仪器,它采用了本单位的四项技术,测量机理与常规方法截然不同。
本传感器可与普通的瓦斯传感器直接代换使用,工作电源和信号传输完全兼容。
它可与目前所有的监控系统和断电仪配套,特别适用于高瓦斯矿井。
本仪器创新点:1.仪器在0.00-100%CH4全量程内连续测量、不停测、不用热导元件、不怕高浓瓦斯冲击。
在量程的低端有很高的测量精度,在量程的高端有良好的线性。
2.应用了特殊的稳零技术,使其具有极好的稳定性和重复性,现场使用可达三个月免调校时间,使用和调试比普通传感器更为简单。
3.仪器的调零、调精度、调报警等项操作完全由红外遥控器在机外进行,无关人员无法介入,提高仪器的可信度;仪器上无调整孔,密封性能好。
4.检测元件寿命长、工作稳定、维护简单、使用方便。
5. 2006年生产的仪器具有报警声响亮功耗低,无启动冲击电流,可以适配各种分站电源。
6. 2006年生产的仪器具有数字化串行输出功能,可有效抑制电磁干扰造成的“冒大数”干扰。
测量范围:低浓型:0.00-10% CH4;高低浓型:0.00-10-100% CH4;测量误差:基本误差:测值×±10% (典型值:测值×±5%)输出信号:脉冲频率200-1000;200-2000;0-500等;0-5000;5-15;模拟信号 : 4-20mA; 1-5mA;串行码元件寿命:≥1.5年响应时间: <20s显示方式:三位0.5''LED数码管工作电源: DC 9-24V;功耗:≤60mA (18V)接线距离: >2km(1.0mm2电缆)报警方式:声光报警报警门限: 0.1-10% CH4可修改断电门限: 0.1-10% CH4可修改报警声强:>85db(1米)断电输出信号:幅度>6 mA检测速度: 1次/2s红外遥控距离:>6m工作方式:连续工作防爆型式:矿用隔爆兼本质安全型Exd[ib]I软件调零范围:±70字。
甲烷传感器探头悬挂标准
≥0.8
0.8
工作面及其回风巷内全部非本质安全型电气设备
AQ1029—2007《煤矿安全监控系统及检测仪器使用管理规范》
(下调20%后数值)
T1监测工作面混合风流瓦斯,T2监测工作面回风流瓦斯,T0监测上隅角瓦斯
以上为AQ标准对瓦斯及探头的规定,山西省对瓦斯管理更为严格,所有探头报警、断电、复电均下调20%。
甲烷传感器或便携式甲烷检测报警仪设置地点
甲烷传感器编号
报警浓度%CH4
断电浓度
%CH4
复电浓度
%CH4
断电范围
采煤工作面上隅角
T0
≥0.8
≥1.2
0.8
工作面及其回风巷内全部非本质安全型电气设备
低瓦斯井采煤工作面
T1
≥0.8
≥1.2
0.8
工作面及其回风巷内全部非本质安全型电气设备
采煤工作面回风巷
T2
SBS-CH4 甲烷气体探测器安装、操作和维护手册说明书
SBS-CH4Methane Gas Detector KitFor applications and processes where Methane gas may be present INSTALLATION, OPERATION & MAINTENANCEINSTRUCTIONSProtects Life, Property and ProfitsElectrical Safety – UL 61010-1Compliant with NFPA 70E® and IEEE RecommendationsPollution Degree 21-800-554-2243*******************Warnings∙This detector is added protection, not a substitute for prudent safety measures, for where methane gas may be present.∙For large or highly-sensitive areas, SBS recommends installing additional sensors for increased coverage area.∙The methane sensor does not provide protection from fires or methane explosions.The relay contacts are intended to be connected to a safety system that would enable audible alarms, system shutdown and ventilation.∙Ensure that installation complies completely with all relevant Local, State, Federal and OSHA safety and health regulations.∙If a sensor enters warning or alarm mode there is a risk of combustion or explosion. To avoid injury, leave the area immediately.∙The sensor is calibrated for operation in air. Tampering with the sensor or operation in environments that are exposed to other types of gases can lead to inaccuratereadings, false alarms or permanent damage.∙Please see troubleshooting guide for list of gases and compounds that may damage or alter a sensor’s performance.∙Uncured silicone compounds or extended exposure to silicone off gassing can give inaccurate readings or false alarms on a sensor.Table of ContentsDescription Page SectionBenefits 5 2.0Specifications 6 4.0Main Control 7 6.0Operation 12 8.0Testing the Sensor 13 10.0Main Unit and Accessories Part No. DescriptionSBS-CH4Methane Gas DetectorIncludes: one (1) main control, one (1) CH4-SENSOR and one (1) 25 ft. cableCH4-JB Junction Box with Knockouts, 4 11/16" X 4 11/16", MetalCH4-SENSOR Methane Gas Sensor Only (No Cable)CH4-SENSOR-25FT Additional/Replacement Methane Gas Sensor with 25 ft. Cable CH4-SENSOR-50FT Additional/Replacement Methane Gas Sensor with 50 ft. Cable CH4-SENSOR-100FT Additional/Replacement Methane Gas Sensor with 100 ft. CableCH4-TESTKIT Field Test Kit for SBS-CH4Includes: case, regulator, tubing and two (2) cylinders of CH4 gas (25%LEL and 50%LEL)CH4-TESTKIT-INTL Field Test Kit for SBS-CH4Includes: case, regulator and tubing – does not include CH4 gas cylindersE190399110Vac 3 Prong AC Cord, 10 Ft., 18-3 AWG1.0 OverviewAt room temperature and pressure, methane is a colorless, odorless gas.Concentrations of 4.4% to 17% CH4 mixed with air can be explosive. Sparks or hot surfaces can ignite methane gas.The SBS-CH4 methane detector acts as a monitor and provides a visual and audible alarm when methane gas is detected. The unit also has a 25%LEL concentration relay that can trigger exhaust fan operation and a 50%LEL concentration relay that can trigger a building management/alarm system (via SCADA/Modbus) before the gas reaches the lower explosive limit (LEL) of 4.4%.2.0 BenefitsIn addition to protecting employees and property, the detector may also reduce the following costs: Energy EfficienciesInstead of continuously running an exhaust fan to prevent methane gas accumulation, use the detector to activate a fan only if the gas concentration reaches 25%LEL.Insurance SavingsInstallation of a detector in areas where batteries are charged may result in a premium reduction.3.0 How it WorksShould the concentration of methane gas in the air surrounding the sensor reach 25%LEL by volume, the “25%LEL Warning” yellow LED will light up on the main control of the unit. In addition, the25%LEL internal relay will energize and can be used to activate a remote exhaust fan.Should the methane gas concentration reach 50%LEL by volume, the “50%LEL Alarm” red LED will light up, the strobe will flash and an audible alarm will sound. In addition, the 50%LEL internal relay will energize and can be used to activate a building management/alarm system (via SCADA/Modbus). The SBS-CH4 provides automatic operation, continuous detection, high sensitivity, stability and solid-state reliability. The unit uses 120/240 Vac 50/60 Hz and/or 12 - 48 Vdc operating voltages.4.0 SpecificationsDimensions∙Main control: 4.7" L x 4.7" W x 1.2" D∙Sensor: 3.1" L x 1.6" W x 0.87" DMounting∙Wall: two 3/16" screws (not included)∙CH4-JB Junction box: 4 11/16" x 4 11/16" 2-gang junction boxPower Requirements/OptionsWarning: Power requirements for the unit and relays should not exceed min/max specifications ∙120 Vac, 50/60 Hz Nominal (Terminal J8)o93 - 121 Vaco250mA / 10W Max∙220 Vac, 50/60 Hz Nominal (Terminal J8)o185 - 242 Vaco125mA / 10W Max∙12-48 Vdc Nominal (Terminal J9)o9 - 58 Vdco600mA / 6W Maxo Note: An earth ground must be supplied to the GND terminal on the AC terminal block when using only the DC power supplyRelays∙25%LEL Warning Relay (Terminal J6)o 1 Normally Open and 1 Normally Closed contacto Rated for 15 A resistive @ 120 Vaco Rated for 10 A resistive @ 277 Vaco Rated for 10 A resistive @ 28 Vdc∙50%LEL Alarm Relay (Terminal J3)o 1 Normally Open and 1 Normally Closed contacto Rated for 0.5A @ 28 VdcTemperature/Humidity∙Operating Temperature Range: 32°F (0°C) to 122°F (50°C)∙Operating Humidity Range: 20-95% non-condensing∙Storage Humidity Range: 5-95% non-condensingMaximum Altitude∙2000 metersAudible Alarm∙85 dB at 10’ @ 1.6 - 3.2 KHzStrobe LED∙*******************.2V5.0 SensorThe CH4-SENSOR consists of an electronic sensing element whose electrical conductivity increases when Methane is detected at its surface. Conductivity of the sensor is proportional to the gas concentration, which is continuously monitored by the electronic alarm circuits.The sensor is calibrated specifically for methane gas (CH 4) and can detect other combustible gases that it is not specifically calibrated for.6.0 Main ControlSensor HeadStrobe AlarmIndividual Sensor Indicators (For troubleshooting, refer to page 14.)Methane SensorCat5 Cable(25 ft. std., 50/100 ft. optional)Main ControlMain Control Indicators (3 LEDs)7.0 InstallationWARNINGAC voltage relay terminals (120/240 Vac) are located within this detector, presenting a hazard toservice technicians. Only qualified technicians should open the detector case and service the internal circuits. Ensure power is removed from the detector relays prior to servicing the unit. Failure to do so may result in injury or death.Mounting and Power OptionsAlarm WiringCH4-JB Junction Box Mountable (optional) Mounts to a standard, 4 11/16" x 4 11/16" 2-gang junction boxHardwire OptionRun AC and/or DC power and alarm wires through back of the unit, into the gang box and out through conduit.E190399 AC Line Cord3-prong grounded AC cord, 18-3 AWGWall MountableIntegrated back mounting plate allows user to easily mount directly to any wall using 3/16" screws (not included).WiringPower and alarm wires can run through the sides of the unit.Input PowerMounting LocationMethane is colorless and odorless; the leaks from a refrigerated liquid container are heavier than air due to increased density of the cold gas, however the gas at ambient temperature is lighter than air and thus rises. The sensor should be installed in proper location for detection of leaking liquid gas, or rising ambient temperature gas accumulation.The detector measures methane gas concentration in the air immediately surrounding the sensor’s surface. The area one sensor will monitor depends on the properties of the compartment or room. Methane gas may accumulate in several areas of the compartment or room and multiplesensors/detectors may be necessary depending upon construction and design of the application.The main control can be mounted wherever is convenient for the user, but should be within the cable length range to connect to each sensor.The sensor should be mounted at the location where leak detection or gas concentration buildup is to be monitored. Each sensor connects with the main control via the cable.Carefully remove the main control cover by removing the two screws located on the front of the cover. Attach the main control to the wall, ceiling or optional junction box using the mounting holes at the top and bottom of the main control’s mounting plate.After the power and relay wiring is complete, connect each cable from main control to each sensor and refasten the main control cover.Power OptionsThe detector has terminal blocks for connections to a single-phase 120/240 Vac 50/60 Hz power source (Terminal J8), and/or a 12-48 Vdc power source (Terminal J9). The power supply inputs are redundant, so the unit can use the DC input as a backup source.RelaysThe detector has two (2) internal alarm relays:∙25%LEL warning relay (Terminal J6) is activated when a sensor detects 25%LEL concentration of methane gas. The 25%LEL relay’s dry contacts are rated at 10A/250 Vac,sufficient for most 1/3 HP exhaust fans.∙50%LEL alarm relay (Terminal J3) is activated when a sensor detects 50%LEL concentration of methane gas. The 50%LEL relay’s dry contacts are rated for 0.5A/28 Vdc.∙Note: For higher current requirements, add an external relay.Mounting OptionsJunction Box MountedFor 120/240 Vac power, use 18-3 gauge stranded wire.For 9 - 58 Vdc power, use 18-2 conductor insulated wire.For relay wires, use stranded wire. Maximum wire size for connector terminations is 14 AWG. Stranded conductors must be terminated in a manner to prevent shorting from one terminal to another by a loose strand. Tin the wires with solder if required.Wall MountedFor 120 Vac power, an 18-3 gauge insulated line cord is required.For 9 - 58 Vdc power, use 18-2 conductor insulated cable from the DC supply.For relay wires, use stranded wire. Maximum wire size for connector terminations is 14 AWG.Disconnection of Supplying PowerWhen the unit is hard wired, an external 10 Amp (minimum) circuit-breaker or switch should be installed to act as a disconnecting device. The circuit-breaker must open all supply conductors simultaneously, be easily reached by operators and be marked as the disconnecting device for the equipment.For Installation of Additional SensorsA maximum of three (3) sensors may be connected to each main control. Multiple detectors and sensors can be installed to meet the space coverage requirements of your particular installation.Locate the additional sensors ’ installation points within cable reach of the main control and mount the sensor. Connect the cables from any additional sensors to the Sensor 2 and Sensor 3 inputs on the main control.SBS supplies a tie-wrap to secure the AC mains ’ wiring. The tie wrap can rotate up to 270 degrees to accommodate your installation.Alarm System ElectronicsPlease refer to the illustration below to identify proper power and relay connection points in the detector. It is advisable to use a pair of 14 gauge or smaller stranded wire for the relay contacts to help reduce any interference within the area that may cause false alarms.Each of the Cat5 sensor input connections has a status indicator LED on the main control, which will illuminate solid green when a sensor is connected and operating normally. A sensor’s corresponding LED will flash at the same rate as the strobe LED when detecting 25%LEL or 50%LEL CH4 concentration. The LED for a sensor that is in alarm mode will flash at the same rate as the strobe LED. The alarming sensor and strobe LED will flash at a faster rate than the LED for a sensor that is only in warning mode.Terminal Connection DiagramUsing the Mechanical Relays1. Remove the front cover of the main control by removing two fix screws and pulling straight offthe body. This will reveal the inner electronics of the alarm box.2. Locate the terminal blocks for the relays and determine which condition you would like therelay to be related to. Use the 25%LEL relay (Terminal J6) for the warning condition and the 50%LEL relay (Terminal J3) for the alarm condition.3. Replace the front cover on the alarm box.8.0 OperationKeep the detector on at all times. The solid green LED for ‘POWER’ on the main control indicates that the detector is powered on.When power is first turned on, a warm up period of 30 seconds will elapse before the unit will function. This delay is to prevent false activation of the internal relays and alarm.Should the concentration of methane gas in the air surrounding the sensor reach 25%LEL by volume, the “25%LEL Warning” yellow LED will light up on the main control of the unit. In addition, the25%LEL internal relay will energize and can be used to activate a remote exhaust fan.Should the methane gas concentration reach 50%LEL by volume, the “50%LEL Alarm” red LED will light up, the strobe will flash and an audible alarm will sound. In addition, the 50%LEL internal relay will energize and can be used to activate a building management/alarm system (via SCADA/Modbus).ConditionMain ControlIndicatorsPower Warning AlarmIndividual SensorIndicatorsRelayClosureAudibleAlarmStrobeNormal Operation(sensor installed)None None NoneCH4 Warning(25%LEL CH4)(blinking green)WarningRelayEnergizedNone NoneCH4 Alarm(50%LEL CH4)(same flash rate as strobe)Warning andAlarm RelayEnergizedON ONSensor/Cable Fault None None NoneCommunicationwith Sensor Lost(plugged in, but not lit)None None NoneMain Control IndicatorsIndividual Sensor Indicators9.0 Electrical TestingA "TEST" button is located on the front of the main control. Push and hold this button for approximately 10 seconds to test the unit's electronic circuitry.The warning and alarm LEDs will light up in sequence, the strobe will flash, the relays will activate whatever is connected to them and the internal warning alarm will sound.Note: The "TEST" button does NOT test the sensor(s) itself –only the unit’s electronic circuitry.10.0 Testing the SensorThe sensors and main controls are factory calibrated. It is recommended to test each sensor’s functionality every 12-18 months with the CH4-TESTKIT.The CH4-TESTKIT is intended for periodic testing of the functionality and proper operation of the system. Once a sensor is installed, calibration or adjustment of the sensor is not possible. Please contact your sales representative if sensor calibration is desired or required.The CH4-TESTKIT includes the following:∙25%LEL (17 liters) CH4 in air calibrated gas canister∙50%LEL (17 liters) CH4 in air calibrated gas canister∙Regulator∙Flexible tubing with sensor head adapterTesting the 25%LEL Warning and 50%LEL Alarm State1. Connect the test fixture to the 25%LEL CH4 air gas cylinder.2. Secure the test fixture to the sensor module connected to sensor by pressing the flexible tubingcompletely over the inlet to the sensor head.3. Turn on the gas flow by slowly cracking then fully opening the valve completely. Please wait 60seconds to ensure the air in the tubing has been purged.4. Continue gas flow and wait for the yellow LED warning to light up and the 25%LEL relay toenergize.5. Turn off gas and remove from sensor.6. Repeat Steps 1-5 above using the 50%LEL CH4 air gas cylinder to activate the 50%LEL alarmand relay. The 50%LEL alarm threshold is connected to the red LED, the audible alarm and the strobe light up, which will activate during testing.7. Repeat steps for every sensor installed.Note: If the unit does not alarm during these tests the sensor may need to be replaced.Replacing the SensorIn a typical operating environment SBS recommends that each sensor be replaced every three years. An abusive operating environment can and will shorten a unit’s useful life. In dusty/dirty applicationsor in situations where a sensor is often subjected to different gases, it is recommended to replace each sensor after one (1) year.11.0 Troubleshooting and MaintenanceNo PowerVerify the AC and/or DC power cables are installed per the connection diagram on page 11.RelaysThe SBS-CH4 system was designed for the relays to operate in a failsafe condition when the power supply is interrupted. If the fan connected to a relay runs as soon as the unit is powered on, the unit has been wired for the use of the Normally Open contact instead of a Normally Closed contact.False AlarmsEach sensor has been calibrated for the detection of methane gas, however any combustible gas that comes in contact with a sensor has the potential to activate the warning and/or alarm relays. Contact with any individual or combination of the following gases could trigger false alarms and/or contaminate a sensor.Gases include but are not limited to:-Acetone-Acetylene-Ammonia-Benzene-Butane-n-Butyl Acetate -Carbon Dioxide -Carbon Monoxide -Ethane-Ethanol-Ethyl Acetate -Ethyl Ether-Ethyl Oxide-Gasoline-Heptane-Hexane-Isopropyl Alcohol-Methane-Methane Cyanide-Methane Sulfide-Methanol-Methyl Ethyl Ketone-Nitric Oxide-Nitric Dioxide-Propane-Propylene Oxide-Styrene-Sulfur Dioxide-Toluene-Turpentine-Vinyl Acetate-XyleneIf a sensor’s warning or alarm condition is reached, ventilate the area with clean air. This should reduce the concentration of most gases and the warning or alarm condition should clear.Note - when a warning occurs at 25%LEL, the warning will not clear until concentrations drop below 0.5%. Similarly, when an alarm occurs at 50%LEL, the alarm will not clear until concentrations drop below 1.5%.Avoid installation in highly corrosive environments where high densities of Methane sulfide, sulfur oxide, chlorine, Methane chloride, etc. may be present. These gases can cause corrosion of the element and the power leads to the circuit board.A sensor’s output characteristics can be affected if the sensor becomes contaminated or exposed to heavy alkaline metals.A sensor cannot operate in a zero or low oxygen content atmosphere.If a sensor collects water condensation, its characteristics may temporarily drift. However, light levels of condensation under normal indoor use should not pose a significant problem with performance.StorageThe longer a sensor is stored prior to being energized, the longer the warm up and stabilization period may become. Storage Humidity Range: 5 - 95% non-condensing.Maintenance TipsTo maintain the unit, it is recommended to:1. Test the detector once a month by pressing the ‘TEST’ button.2. Vacuum the alarm cover once a month to remove accumulated dust.3. Never use detergents or solvents to clean the unit or sensor. Chemicals can permanentlydamage or temporarily contaminate a sensor.4. Avoid spraying air fresheners, hair spray, paint or other aerosols near a sensor.5. Never paint the unit or sensor. Paint will seal the vents and interfere with proper sensoroperation.WARNINGSDo not disassemble unit or attempt to repair or modify any component of this instrument. This instrument contains no user serviceable parts, and substitution of components may impair intrinsic safety, which may adversely affect product performance and result in injuryThe SBS-CH4 Methane Alarm System is not a standalone safety device and does not provide protection from methane explosions. The relay contacts are intended to be connected to a safety system, enabling audible alarms, system shutdown, ventilation, or other measures to ensure monitoring of methane gas occurs before concentrations reach dangerous levels.The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Storage Battery Systems, LLC reserves the right to make changes without further notice to any product, datasheet, technical data bulletin, or website.Storage Battery Systems, LLC makes no warranty, representation of guarantee regarding the suitability of its product for any particular purpose, nor does Storage Battery Systems, LLC assume any liability arising out of the application or use of any product and specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters can and do v ary in different applications. All operating parameters, including “Typical” must be validated for each customer application by customer’s technical experts.Storage Battery Systems, LLC products are not designed, intended, or authorized for use in any application in which the failure of the SBS product could create a situation where personal injury or death may occur.Should buyer purchase or use SBS products for any such unintended or unauthorized application, Buyer shall indemnify and hold Storage Battery Systems, LLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if claim alleges that Storage Battery Systems, LLC was negligent regarding the design or manufacture of the part.In the case of a defect in the sensor, Storage Battery Systems, LLC shall not be liable for any damages which may result, including, but not limited to, loss of revenue, property, or life. In an event, Storage Battery Systems, LLC shall limit liability to replacement of the defective unit. Storage Battery Systems, LLC does not convey any license under its patent rights nor the rights of others.。
甲烷CH4气体浓度检测探测器
甲烷CH4气体浓度检测探测器甲烷CH4气体浓度检测探测器适用于各种环境和特殊环境中的甲烷CH4气体浓度和泄露,在线检测及现场声光报警,对危险现场的作业安全起到了预警作用,此仪器采用进口的电化学传感器和微控制器技术,具有信号稳定,精度高,重复性好等优点,防爆接线方式适用于各种危险场所,并兼容各种控制器,PLC,DCS等控制系统,可以同时实现现场报警和远程监控,报警功能,4-20mA标准信号输出,继电器开关量输出。
甲烷CH4气体浓度检测探测器产品特性:①进口电化学传感器具有良好的抗干扰性能,适用寿命8年。
②采用先进微处理技术,响应速度快,测量精度高,稳定性和重复性好。
③检测现场具有具有现场声光报警功能,气体浓度超标即时报警,是危险场所作业的安全保障。
4现场带背光大屏幕LCD显示,直观显示气体浓度,类型,单位,工作状态等。
5独立气室,更换传感器无须现场标定,传感器关键参数自动识别。
6全量程范围温度数字自动跟踪补偿,保证测量准确性。
甲烷CH4气体浓度检测探测器技术参数:检测气体:空气中的甲烷CH4检测范围:0~100ppm,0~200ppm,0~1000ppm,0~1000ppm,0~5000ppm,100%LEL可选。
分别率:0.01ppm(0~100ppm);0.1ppm(0~1000ppm);1ppm(0~10000ppm以上);0.1LEL.工作方式:固定式连续工作,扩散式,管道式,流通时,泵吸式可选。
检测误差:≦1%(F.S)响应时间:≦10S输出信号:电流信号输出4-20MA报警方式:2路无源节点信号输出,报警点可设置。
工作环境:-20℃~50℃(特殊要求:(-40℃~+70℃)相对湿度:≦90%RH工作电压:DC12~30V传感器寿命:3年防爆形式:探头变送器及传感器均为隔爆型。
防爆等级:Exd II CT6连接电缆:三芯电缆(单根线径≧1.5mm);建议选用屏蔽电缆。
连接距离:≦1000m.防护等级:IP65.外形尺寸:183X143X107mm.重量:1.5Kg.甲烷CH4气体浓度检测探测器的简单介绍:甲烷CH4报警器●自动温度补偿,零点,满量程漂移补偿●防高浓度气体冲击的自动保护功能●全软件校准功能,用户也可自行校准,用3个按键实现,操作简单●二线制4-20mA输出甲烷CH4气体浓度检测探测器的应用场所医药科研、制药生产车间、烟草公司、环境监测、学校科研、楼宇建设、消防报警、污水处理、工业气体过程控制石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、、锅炉房、垃圾处理厂、隧道施工、输油管道、加气站、地下燃气管道检修、室内空气质量检测、危险场所安全防护、航空航天、军用设备监测等。
GJC4100煤矿用高低浓度甲烷传感器
•GJC4/100煤矿用高低浓度甲烷传感器(以下称“仪器”),是一种用于煤矿井下的定置型甲烷传感器。
采用贴片工艺,功耗小,适用于具有瓦斯突出的矿井井下采掘工作面,回风巷道及临时停工的盲巷口等场所,连续监测井下环境中甲烷(CH4)含量。
该仪器可与各种煤矿环境监测系统、监控分站、断电仪配套使用。
该仪器除就地数字显示被测环境中的甲烷含量外,还可输出与甲烷含量成正比例的电信号供监测系统处理及地面显示。
•1、仪器特点•*微电脑处理芯片:采用新型单片微机和高集成数字化电路,使电路结构简单、性能可靠,便于维修调试。
•*性能稳定:性能稳定,本仪器所采用的传感器元件是长寿命、高稳定的载体催化元件,•调校周期长。
•*灵敏度高:高性能的传感器元件加上仪器内部软件的自动非线性补偿使得仪器对甲烷的检测具有较高的灵敏度。
•*可靠性高:本仪器具有开机自检、自动稳零、精度校正等功能,且采用红外遥控调校,整机没有任何调整孔,仪器的零点、精度的调整,报警值、断电值的设定以及输出信号的设定均由红外遥控器控制。
可以避免开盖调试,减小机械损伤,提高整机的密封性,延长了仪器使用寿命。
•*功耗低:本仪器采用特殊的电源电路,用软、硬件相结合的方法使得整机电流很小,最大工作电流仅有50mA。
•*测量范围宽:本仪器只须一对催化元件就可连续检测0~100%甲烷,没有高低浓转换过程,不怕高浓瓦斯冲击。
•*兼容性好:本仪器可由红外遥控器灵活设置多种输出信号制式,几乎可以与国内所有类型的分站连接。
•*外观精巧、结构简单:本仪器电路板采用贴片式焊接,外观轻巧美观,结构精致合理,密封性极好,便于携带。
•测量范围:(0~4~100%CH)•主要技术指标:•1、适用条件:•环境温度:0℃~40℃•相对湿度:≤95%RH•大气压力:80~110KPa•风速:6~8m/s•2、主要技术参数:• 2.1工作电压波动范围:9V~24V DC• 2.2测量范围:0~4%~100%CH4• 2.3基本测量误差:•测量范围,%CH4基本误差,%CH4•0.00~1.00±0.10• 1.00~3.00真值的±10• 3.00~4.00±0.30• 4.00~40.00真值的±10•>40.00测量上限的±10•3、外壳:•外壳材料:锌合金•外型尺寸:225mm×166mm×53mm•重量:≤1.00Kg。
GJC4甲烷传感器说明书
五、安装方法 1. 将传感器悬挂在测量位置的上方; 2. 将传感器显示窗置于便于观察的位置,并注意不要遮挡显示窗。
六、使用方法 1.安装
传感器应安装在井下无淋水的地点。 传感器由关联设备提供电源。 注意:连接前应确认关联设备输出电压符合传感器输入电压要求。 2.联接方式 传感器由四芯航空插头与外部设备联接,其各接线端子功能如下表 2:
4. 传感器一般应能在输入电压 DC(9~24)V 范围内正常工作;
5 本安参数:Ui:DC 18V;Ii:100mA;Ci:0μF;Li:0mH;
6 测量范围:(0.00~4.00)%CH4;
7 显示值稳定性:在(0.00~4.00)%CH4 范围内,当甲烷浓度保持稳定时,传感器显示值或输出信
号值(换算为甲烷浓度值)的变化量应不超过 0.04%CH4;
四、主要技术参数及性能
1. 工作环境条件:
a)温度:(0~40)℃;
b)相对湿度:≤98%;
c)大气压力:(80~116)kPa;
d)风速:(0~8)m/s;
e)适用场所:传感器适用于煤矿井下有甲烷、煤尘爆炸性气体混合物环境中;
2. 贮存温度:(-40~60)℃;
3. 额定工作电压:DC18V;额定工作电流:≤100mA;
11.报警方式:声光报警,红色报警光信号能在黑暗环境中距离 20m 远处清晰可见,报警声级强度 在距其 1m 远处的声响信号的声压级大于 80dB;
12.显示方式:三位 LED 数码管显示; 13.输出信号制式:
频率型:(200~1000)Hz,对应(0.00~4.00)%CH4(脉冲宽度大于 0.3ms); 14.显示分辩率:0.01%CH4 ; 15.响应时间:≤20s;
8. 敏感元件工作寿命:>1 年;
甲烷传感器的分类
甲烷传感器的分类甲烷(CH4)是一种常见的有机化合物,也是一种重要的温室气体。
由于甲烷具有易燃易爆的性质,以及对人体健康的危害,因此需要对甲烷进行监测和检测。
甲烷传感器是一种能够实时检测环境中甲烷浓度的装置,根据其工作原理和应用领域的不同,可以分为多种分类。
一、依据工作原理分类1. 热导式甲烷传感器热导式甲烷传感器利用甲烷气体的导热性质来检测甲烷浓度。
传感器内部有一个加热元件和一个测温元件,当甲烷气体进入传感器时,甲烷分子与加热元件碰撞,导致温度上升,测温元件会感知到温度变化从而测量出甲烷浓度。
2. 电化学甲烷传感器电化学甲烷传感器通过氧化还原反应来检测甲烷浓度。
传感器内部有一对电极,其中一个电极上涂有催化剂,当甲烷气体进入传感器时,催化剂会促使甲烷与氧气发生反应产生电流,通过测量电流的大小可以得知甲烷浓度。
3. 光学甲烷传感器光学甲烷传感器利用甲烷分子对特定波长的光的吸收特性来检测甲烷浓度。
传感器内部有一个光源和一个光电探测器,光源发出特定波长的光,当甲烷气体进入传感器时,会吸收部分光,通过测量吸收光的强度可以得知甲烷浓度。
二、依据应用领域分类1. 工业甲烷传感器工业甲烷传感器主要用于工业场所对甲烷泄漏进行监测,以防止事故的发生。
这种传感器通常采用高灵敏度的电化学传感器,能够快速、准确地检测到低浓度的甲烷气体。
2. 家用甲烷报警器家用甲烷报警器是一种用于家庭环境的甲烷传感器,用于监测家庭中甲烷泄漏,以保护家庭成员的生命安全。
这种传感器通常采用热导式或电化学传感器,具有高灵敏度和稳定性。
3. 车载甲烷传感器车载甲烷传感器主要用于汽车和公交车等交通工具中,用于监测车辆燃料系统中的甲烷泄漏,以避免事故和环境污染。
这种传感器通常采用光学传感器,具有快速响应和高灵敏度。
总结:甲烷传感器根据其工作原理和应用领域的不同,可以分为热导式、电化学和光学甲烷传感器。
在实际应用中,根据不同的需求可以选择合适的甲烷传感器,以实现对甲烷浓度的准确监测和及时报警,保障人员和环境的安全。
GJC4低浓度甲烷传感器 使用说明书
北京消防救护器材厂GJC4低浓度甲烷传感器产品使用说明书执行标准:AQ6203-2006、GB3836-2010版本号:Ver1.0出版日期:2011-05-01在安装、使用产品前请仔细阅读产品使用说明书北京消防救护器材厂目录一、用途 (2)二、型号及含义 (2)三、外形尺寸、质量及材质四、主要特点 (2)五、主要技术参数 (2)六、工作原理 (3)七、结构 (3)八、使用与维护 (3)九、注意事项 (4)十、典型故障判断及处理 (4)十一、发货清单 (5)十二、资质证明编号 (5)附录北京消防救护器材厂010-警示:维修时不得改变本安电路和与本安电路有关的元器件的电气参数、规格和型号!本安关联产品不得随意改变配置!一、用途GJC4低浓度甲烷传感器(以下简称传感器)是为满足我国煤矿监测井下甲烷浓度的需要而研制的。
它可以连续自动地将井下甲烷浓度转换成标准电信号输送给配接设备,并具有就地显示沼气浓度值,超限声光报警等功能。
传感器经国家防爆检验机关进行联机检验后, 可与国内各类型监测系统及断电仪、风电瓦斯闭锁装置配套,适宜在煤矿采掘工作面、机电硐室,回风巷道等地点固定使用。
二、型号及含义量程范围(%CH4)催化原理甲烷传感器三、外形尺寸、质量及材质a)外形尺寸:270 × 155 × 55mmb)重量:≤1.3k g;c)外壳材质:不锈钢。
四、主要特点1.采用新型单片微机和高集成数字化电路,使电路结构简单,性能可靠,便于维修与调试。
•2.实现了红外遥控调校零点、标校点、报警点等功能,使调校方便简单。
3.增加了传感器断电控制功能,并可任意设定断电点,实现了一机多用。
4.采用新型开关电源,降低了整机功耗,增加了仪器传输距离。
5.增加了故障自检功能,便于使用与维护。
6.设计了新型高强度外壳结构,增强了仪器抗冲击能力。
五、主要技术参数1、适用条件环境温度:0℃~40℃2相对湿度:≤98%RH大气压力:80kPa~116kPa风速:0m/s~8m/s适用于含有瓦斯或煤尘爆炸危险的煤矿井下。
GJC4低浓度甲烷传感器--使用说明书资料
北京消防救护器材厂GJC4低浓度甲烷传感器产品使用说明书执行标准:AQ6203-2006、GB3836-2010版本号:Ver1.0出版日期:2011-05-01在安装、使用产品前请仔细阅读产品使用说明书北京消防救护器材厂目录一、用途 (2)二、型号及含义 (2)三、外形尺寸、质量及材质四、主要特点 (2)五、主要技术参数 (2)六、工作原理 (3)七、结构 (3)八、使用与维护 (3)九、注意事项 (4)十、典型故障判断及处理 (4)十一、发货清单 (5)十二、资质证明编号 (5)附录警示:维修时不得改变本安电路和与本安电路有关的元器件的电气参数、规格和型号!本安关联产品不得随意改变配置!一、用途GJC4低浓度甲烷传感器(以下简称传感器)是为满足我国煤矿监测井下甲烷浓度的需要而研制的。
它可以连续自动地将井下甲烷浓度转换成标准电信号输送给配接设备,并具有就地显示沼气浓度值,超限声光报警等功能。
传感器经国家防爆检验机关进行联机检验后, 可与国内各类型监测系统及断电仪、风电瓦斯闭锁装置配套,适宜在煤矿采掘工作面、机电硐室,回风巷道等地点固定使用。
二、型号及含义量程范围(%CH4)催化原理甲烷传感器三、外形尺寸、质量及材质a)外形尺寸:270 × 155 × 55mmb)重量:≤1.3k g;c)外壳材质:不锈钢。
四、主要特点1.采用新型单片微机和高集成数字化电路,使电路结构简单,性能可靠,便于维修与调试。
•2.实现了红外遥控调校零点、标校点、报警点等功能,使调校方便简单。
3.增加了传感器断电控制功能,并可任意设定断电点,实现了一机多用。
4.采用新型开关电源,降低了整机功耗,增加了仪器传输距离。
5.增加了故障自检功能,便于使用与维护。
6.设计了新型高强度外壳结构,增强了仪器抗冲击能力。
五、主要技术参数1、适用条件环境温度:0℃~40℃相对湿度:≤98%RH大气压力:80kPa~116kPa风速:0m/s~8m/s适用于含有瓦斯或煤尘爆炸危险的煤矿井下。
甲烷CH4浓度检测探头
甲烷CH4浓度检测探头甲烷CH4浓度检测探头产品描述:甲烷CH4浓度检测探头适用于各种环境和特殊环境中的甲烷CH4甲烷CH4气体浓度和泄露,在线检测及现场声光报警,对危险现场的作业安全起到了预警作用,此仪器采用进口的电化学传感器和微控制器技术,具有信号稳定,精度高,重复性好等优点,防爆接线方式适用于各种危险场所,并兼容各种控制器,PLC,DCS 等控制系统,可以同时实现现场报警和远程监控,报警功能,4-20mA标准信号输出,继电器开关量输出。
甲烷CH4浓度检测探头产品特性:进口电化学传感器具有良好的抗干扰性能,适用寿命8年。
采用先进微处理技术,响应速度快,测量精度高,稳定性和重复性好。
检测现场具有具有现场声光报警功能,气体浓度超标即时报警,是危险场所作业的安全保障。
4现场带背光大屏幕LCD显示,直观显示气体浓度,类型,单位,工作状态等。
5独立气室,更换传感器无须现场标定,传感器关键参数自动识别。
6全量程范围温度数字自动跟踪补偿,保证测量准确性。
检测气体:空气中的甲烷CH4气体检测范围:0~100ppm,0~200ppm,0~1000ppm,0~1000ppm,0~5000ppm,100%LEL可选。
分别率:0.01ppm(0~100ppm);0.1ppm(0~1000ppm);1ppm(0~10000ppm以上);0.1LEL.工作方式:固定式连续工作,扩散式,管道式,流通时,泵吸式可选。
检测误差:≦1%(F.S)响应时间:≦10S输出信号:电流信号输出4-20MA报警方式:2路无源节点信号输出,报警点可设置。
工作环境:-20℃~50℃(特殊要求:(-40℃~+70℃)相对湿度:≦90%RH工作电压:DC12~30V传感器寿命:3年防爆形式:探头变送器及传感器均为隔爆型。
防爆等级:Exd II CT6连接电缆:三芯电缆(单根线径≧1.5mm);建议选用屏蔽电缆。
连接距离:≦1000m.防护等级:IP65.外形尺寸:183X143X107mm.重量:1.5Kg.甲烷CH4浓度检测探头简单介绍:甲烷CH4浓度检测探头●自动温度补偿,零点,满量程漂移补偿●防高浓度气体冲击的自动保护功能●全软件校准功能,用户也可自行校准,用3个按键实现,操作简单●二线制4-20mA输出甲烷CH4浓度检测探头应用场所医药科研、制药生产车间、烟草公司、环境监测、学校科研、楼宇建设、消防报警、污水处理、工业气体过程控制石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、、锅炉房、垃圾处理厂、隧道施工、输油管道、加气站、地下燃气管道检修、室内空气质量检测、危险场所安全防护、航空航天、军用设备监测等。
红外甲烷传感器用于矿井作业中可燃气体CH4检测
红外甲烷传感器用于矿井作业中可燃气体CH4检测通常在煤矿开采过程中会从煤岩层排放出大量的有害气体,也就是人们常说的瓦斯。
瓦斯的主要成分是碳氢化合物,如一氧化碳、H2S、甲烷等。
其中,甲烷(CH4)占83-89%,是煤形成过程中形成并储存在煤层中的气体,是煤矿中最有害的气体。
近年来,我国煤矿井下事故频发,伤亡人数超过所有重大事故的一半。
因此,煤矿井下气体检测非常重要。
甲烷气体无色、无嗅、无嗅,密度为0.7164千克/米,虽然无毒,但其对人体也有很大的危害,主要危害是超标会导致窒息和死亡。
并且,它是易燃易爆的气体。
工采网了解到当它与空气混合达到一定浓度时,暴露在高温火源下会燃烧或爆炸。
按体积计算,甲烷浓度在5.3-15.0%时具有爆炸性,矿井中甲烷气体的积聚已成为困扰煤矿安全生产的一大难题。
事实上,煤矿工业生产过程的许多环节都会产生易燃易爆、有毒有害的气体,并不止甲烷一种,比如一氧化碳等气体在煤矿中很常见。
由于煤矿环境更加复杂,在许多情况下将使用机器来操作它。
煤矿机器人的使用是确保安全的主要措施,煤矿机器人具有图像和传输功能,其中监测气体浓度的功能就是利用的气体传感器。
针对煤矿中监测的可燃性气体甲烷浓度的监测可选用甲烷传感器,工采网代理的英国Clairair 红外气体传感器- S509是依据比尔-郎伯定律和红外光谱理论研制成的,可以精确探测甲烷,二氧化碳,碳氢化合物等,可以工作在高湿环境中。
为了人身和财产安全着想,在煤矿施工过程中最好也定时监测工作环境可燃气体的浓度情况,以免造成不必要的损失。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
甲烷CH4检测仪
甲烷CH4检测仪特点:
★是款内置微型气体泵的安全便携装置
★整机体积小,重量轻,防水,防爆,防震设计.
★高精度,高分辨率,响应迅速快.
★采用大容量可充电锂电池,可长时间连续工作.
★数字LCD背光显示,声光、振动报警功能.
★上、下限报警值可任意设定,自带零点和目标点校准功能,内置
温度补偿,维护方便.
★宽量程,最大数值可显示到50000ppm、100.00%Vol、100%LEL.
★数据恢复功能,免去误操作引起的后顾之忧.
★显示值放大倍数可以设置,重启恢复正常.
★外壳采用特殊材质及工艺,不易磨损,易清洁,长时间使用光亮如新.
甲烷CH4检测仪产品特性:
★是款内置微型气体泵的高精度的手式安全便携装备;
★进口电化学传感器具有良好的抗干扰性能,使用寿命长达3年;
★采用先进微处理器技术,响应速度快,测量精度高,稳定性和重复性好;
★检测现场具有现场声光报警功能,气体浓度超标即时报警,是危险现场作业的安全保障;
★现场带背光大屏幕LCD显示,直观显示气体浓度/类型/单位/工作状态等;
★全量程范围温度数字自动跟踪补偿,保证测量准确性;
★半导体纳米工艺超低功耗32位微处量器;
★全软件自动校准,传感器多达6级目标点校准功能,保证测量的准确性和线性,并且具有数据恢复功能;★全中文/英文操作菜单,简单实用,带温度补偿功能;
★防高浓度气体冲击的自动保护功能;
甲烷CH4检测仪技术参数:
检测气体:空气中的甲烷CH4气体检测气体
检测范围:0-100ppm、500ppm、1000ppm、5000ppm、0-100%LEL
分辨率:0.1ppm、0.1%LEL
显示方式:液晶显示
温湿度:选配件,温度检测范围:-40~120℃,湿度检测范围:0-100%RH
检测方式:扩散式、流通式、泵吸式可选安装方式:壁挂式、管道式检测精度:≤±3%线性误差:≤±1%
响应时间:≤20秒(T90)零点漂移:≤±1%(F.S/年)恢复时间:≤20秒重复性:≤±1%
信号输出:①4-20mA信号:标准的16位精度4-20mA输出芯片,传输距离1Km
②RS485信号:采用标准MODBUS RTU协议,传输距离2Km
③电压信号:0-5V、0-10V输出,可自行设置
④脉冲信号:又称频率信号,频率范围可调(选配)
⑤开关量信号:标配2组继电器,可选第三组继电器,继电器无源触点,容量220VAC3A/24VDC3A
传输方式:①电缆传输:3芯、4芯电缆线,远距离传输(1-2公里)
②GPRS传输:可内置GPRS模块,实时远程传输数据,不受距离限制(选配)
接收设备:用户电脑、控制报警器、PLC、DCS、等
报警方式:现场声光报警、外置报警器、远程控制器报警、电脑数据采集软件报警等
报警设置:标准配置两级报警,可选三级报警;可设置报警方式:常规高低报警、区间控制报警
电器接口:3/4″NPT内螺纹、1/2″NPT内螺纹,同时支持2种电器连接方式
防爆标志:ExdII CT6(隔爆型)壳体材料:压铸铝+喷砂氧化/氟碳漆,防爆防腐蚀
防护等级:IP66工作温度:-30~60℃
工作电源:24VDC(12~30VDC)工作湿度:≤95%RH,无冷凝
尺寸重量:183×143×107mm(L×W×H)1.5Kg(仪
器净重)
工作压力:0~100Kpa
标准配件:说明书、合格证质保期:一年
甲烷CH4检测仪简单介绍:
丙酮气体检测仪报警器高精度、高分辨率,响应快速,超大容量锂电充电电池,采样距离远,LCD背光显示,声光报警功能,上、下限报警值可任意设定,可进行零点和任意目标点校准,操作简单,具
有误操作数据恢复功能.
甲烷CH4检测仪应用场所:
医药科研、学校科研、制药生产车间、烟草公司、环境检测、楼宇建设、消防报警、污水处理、石油石化、化工厂、冶炼厂、钢铁厂、煤炭厂、热电厂、锅炉房、加气站、垃圾处理厂、隧道施工、输油管道、航空航天、工业气体过程控制、室内空气质量检测、地下燃气管道检修、危险场所安全防护、军用设备检测等。