I/O信号设置

1.651板设置

○1DO1~DO8(32~63 Mapping)

Name do1

Type of signal Digital Output

Assigned to Unit Board10

Unit Mapping 32

○2DI1~DI8(0~31 Mapping)

Name di1

Type of signal Digital Input

Assigned to Unit Board10

Unit Mapping0

注:652板设置DO1~DO16(0~31 Mapping) DI1~DI16(0~31 Mapping)

○3AO1

Name AO1

Type of signa l Analog Output

Assigned to Unit Board10

Unit Mapping0-15

……

Analog Encoding Type Unsigned

Maxmum Logical Value315

Maxmum Physical Value10

Maxmum Physical Value Limit10

Maxmum Bit Value65535

Minimum Logical Value 4

Minimum Physical Value0

○4AO2

Name AO1

Type of signa l Analog Output

Assigned to Unit Board10

Unit Mapping16-31

……

Analog Encoding Type Unsigned

Maxmum Logical Value315

Maxmum Physical Value10

Maxmum Physical Value Limit10

Maxmum Bit Value65535

Minimum Logical Value 4

Minimum Physical Value0

如果是TIG焊,OTC的315,电流设置4~340A;(最小最大逻辑值)

如果是MAG焊,松下的350,电流设置27.5~360A,电压设置12~40.8V;松下的500,电流设置27.5~500A,电压设置12~48.8V。

OTC的350,电流设置30~400A,电压设置12~38V;

○5GO

Name GO1

Type of signa l Group Output

Assigned to Unit Board10

Unit Mapping37-38

○6GI

Name GI1

Type of signa l Group Output

Assigned to Unit Board10

Unit Mapping5-7

7.加I/O板

Name Board10

Type of Unit d651

Connected to Bus DeviceNet1 (Local / Virtual1 / DeviceNet1)

……

DeviceNet Address10

Unit Startup state Activated

……NO