Rexroth Indra Control VCP 20
Rexroth PSI 6xxx.000
LT-IB Operator Interface Technical Information 1070087066 Edition 02
II Bosch Rexroth AG Electric Drives PSI 6xxx.000 1070087066 / 02
and Controls
Title Rexroth PSI 6xxx.000
LT-IB operator interface
Type of Documentation Technical Information
Document Typecode DOK-PS6000-LT-IB*****-FK02-EN-P
Purpose of Documentation The present manual provides information on
●Installation and
●functionality
of the “LT-IB” operator interface/parameterization software.
Record of Revisions Description Release
Notes
Date
−−−−
DOK-PS6000-LT-IB*****-FK02-EN-P 03.2005
Copyright © Bosch Rexroth AG, 2003−2005
Copying this document , giving it to others and the use or
communication of the contents thereof without express
authority, are forbidden. Offenders are liable for the payment
of damages. All rights are reserved in the event of the grant
of a patent or the registration of a utility model or design (DIN
34-1).
Validity The data specified above only serve to describe the
product. No statements concerning a certain condition or
suitability for a certain application can be derived from our
information. The given information does not release the
user from the obligation of own judgement and verification. It
must be remembered that our products are subject to a
natural process of wear and aging.
Published by Bosch Rexroth AG
Postfach 11 62
D-64701 Erbach
Berliner Strafle 25
D-64711 Erbach
Tel.: +49 (0) 60 62/78-0
Fax: +49 (0) 60 62/78-4 28
Abt.: BRC − WS/VTR
Contents
Contents
Page
3 Operation 3−1
3.1 Starting / Exiting the software 3−1
3.2 Setting the basic parameters 3−2
3.3 Parameterizing the setpoint input 3−9
3.4 Setting the date/time 3−11 3.5 Displaying the device type and the firmware version 3−11
3.6 Displaying the error log 3−11
3.7 Fault reset 3−12
3.8 Backing-up data 3−12
3.9 Restoring data backups 3−13
3.10 Triggering device Reset 3−13 3.11 Loading factory setting of the device 3−14
Operation
3 Operation
3.1 Starting / Exiting the software
★Before starting the LT-IB software, you should make sure that the 24 V supply voltage for the digital welding current source has been switched
on.
This is indicated by the “LOGIC” LED on the front panel of the interface
module:
LOGIC LED, green. Is on if 24 V DC (logic
supply voltage) is available.
●Start the LT-IB software by double-clicking on the link symbol created
in the course of installation.
☞If the program window remains empty after the start, or if it closes
again automatically, the software is not able to detect a digital welding
current source at either of the serial interfaces of the PC. In this case, you should check whether
●the connecting cable has been properly wired and plugged in.
●the 24 V supply to the digital welding current source has been
switched on.
If a digital welding current source is connected and has been
detected, the main menu of the software will appear as follows:
Device type and
firmware version of
the digital welding
current source
connected
Main menu
Input prompt