6.Settings Explainations on the LCD of the 2nd Generation GTIL: G2 LCD屏幕设置说明
The GTIL including various functions,all functions should configurate on the LCD setting page.Please see below explainations:
G2逆变器有很多功能,所有功能都应在LCD设置页面配置。
请参阅以下说明
6.1. Limit Mode: External limiter and Internal limiter are settable,
6.1.防逆流模式:外置防逆流和内置防逆流可选
Limit mode+External limiter both selected means work under external limiter mode.
防逆流模式+外置防逆流两个都选就是逆变器在外置防逆流的模式下工作
Limit mode+Internal limiter both selected means work under external limiter mode.
防逆流模式+内置防逆流两个都选就是逆变器在内置防逆流的模式下工作
(蓝色新款都是内置防逆流,请勾选Limit mode+internal limiter)
6.2.LCD back light: Select it, LCD will always on. Unselect it, LCD will auto turn
off after about 10s without any action on LCD button. Press any of the button to light LCD again.
6.2.LCD背光灯:选择它,LCD屏幕将一直亮着。
取消选择它,如果10秒之内一直未操作就会自动熄灭。
按任意按钮再次点亮LCD。
6.3.Remote Num: while using with WIFI plug for monitoring, set by 1.While using
with the WIFI-RTU(one RTU can monitoring multiple inverters),set monitored inverter numbers.
6.3.远程个数:使用WIFI插头进行监控时,设置为1.使用WIFI-RTU(一个RTU 可以监控多个逆变器)时,设置监控的逆变器个数。
6.4.Bat or solar limited current mode: This function is usable while using with
battery. the setted voltage will be the cut off voltage, this means while battery discharged to the setted voltage point or below setted point, inverter will auto disconnect from the battery and stop operating. This can prevent the battery from over discharged. The setted current means inverter will discharge the battery at this current level. MPPT function of the inverter will auto invalid when working under this setting. Set is 0.1V/step.
6.4.电池或太阳能限制电流模式:此功能可在使用电池时使用。
设定电压为截止电压,这意味着当电池放电至设定电压点或低于设定值时,逆变器将自动断开电池并停止运行。
这可以防止电池过度放电。
设定电流意味着逆变器将以此电流水平对电池放电。
在此设置下工作时,逆变器的MPPT功能将自动失效。
设定为0.1V /步。
(比如上图220*0.1V=22V)
6.5.Reboot voltage: This setting voltage means while battery charged back, the
inverter will auto restart after voltage reached the setting point. It convenient the user and make the function very flexible. Set is 0.1V/Step.
6.5.重启电压:此设定电压表示电池充电后,逆变器将在电压达到设定值后自动重启。
方便用户使用,功能非常灵活。
设定为0.1V /步。
6.6.Battery and solar limited power mode: At this working mode, cut off
voltage setting is same as 6.4,and the power setting is the maximum output power of the inverter. by this setting, user can limit the output power manually.
6.6.电池和太阳能限制功率模式:在此工作模式下,截止电压设置与6.4相同,功率设置为逆变器的最大输出功率。
通过此设置,用户可以手动限制输出功率。