微量元素地球化学行为

微量元素地球化学行为
微量元素地球化学行为

微量元素地球化学行为

微量元素的测定方法:

Recently, a novel method was developed at IFREMER for quantifying trace element abundances in seawater by ICP-MS, which involved pre-concentration using Fe coprecipitation and addition of a Tm spike [10]. The addition of Tm spike in the samples prior to

co-precipitation produces a Tm anomaly in the resulting chondrite-normalized REE patterns, which can be used to determine the Tm concentration in the sample solutions and serves as internal standard for the remaining elements [23,24]. This method was shown to be well suited for the determination of precise and accurate concentrations for REE, Y, V, Hf, Zr and Th in seawater. However, the presence of relatively high blank levels (e.g. up to 7 pg for

light REEs), due to the addition of Fe for co-precipitation, required analysis of large volume samples (100 ml) and prevented accurate determination of key trace elements (e.g. Mn, Co, Cr, Ni, Cu, Sc).

In this study, we have investigated the suitability of combining the Tm addition method with Mg(OH)2 co-precipitation for determining trace element abundances in seawater. The recommended procedure reported in this study allows simultaneous determination of the REEs + Y and a few other trace elements (Cr, Co, Mn) in small volume (25ml) seawater samples.

近日,在法国海洋开发研究所开发的一种新的方法量化微量元素

ICP-MS,这涉及到使用铁共沉淀预浓缩海水中丰

和相加的Tm尖峰[10]。前的样品中添加的Tm穗

共沉淀法生产的Tm异常产生的球粒陨石标准化REE模式,

它可以被用来确定的Tm的样品溶液中的浓度,并用作

内部标准,其余的元素[23,24]。这种方法被证明是良好

稀土元素,铪,Y,V,Zr和适合于精确和准确的浓度测定

钍在海水中。但是,存在相对高的空白水平(例如,高达7皮克

轻稀土元素),由于共沉淀添加Fe的体积大,所需的分析

样品(100毫升)和防止准确测定的关键微量元素(如锰,钴,

铬,镍,铜,钪)。

在这项研究中,我们已经调查了相结合的Tm的添加方法与适宜

镁(OH)2共沉淀法测定痕量元素丰度的海水中。“

本研究报告所建议的程序可以同时测定

稀土+ Y和其他一些微量元素(铬,钴,锰),体积小(25毫升)海水

样本。

数据表达与数据解释及讨论:

Figure 1.Effect of successive Mg(OH)2 co-precipitations on trace element scavenging.

The efficiency of successive co-precipitations in scavenging rare earth and other trace elements

(Hf, Th, Cr, Co, Mn, Y and Zr) from our in house coastal seawater standard (Dellec SW) is illustrated as measured ICP-MS intensities (cps) versus the number N of successive co-precipitations. There were 24 replicate samples (n=24) analysed for the first coprecipitation experiment (N1); n=6 for N2; n=6 for N3; n=6 for N4 and n=24 for the last series of successive coprecipitation experiments (N5). In each panel, the thick line indicates the mean background intensity obtained during the course of our experiments for a 2% sub-boiled HNO3 solution.

图1。连续的Mg(OH)2的影响合作降水微量元素清除。

ICP-MS测量强度,连续的共同沉淀的效率,说明在清除稀土及其他微量元素(HF,钍,铬,钴,锰,Y和Zr)从我们的房子沿海的海水标准(Dellec SW)(厘泊)对的数目N的连续的共同沉淀。有24个重复样品组(n =24),分析第一共沉淀实验(N1); n = 6时N2;每组6 N4和n= 24的最后一个系列的连续共沉淀实验(n = 6时N3; N5)。在每个面板中,粗线表示的平均期间,我们的实验过程中为2%的子煮HNO3溶液得到的背景强度。

Figure 2. Co-precipitation yields during Mg co-precipitation.

The average percent recoveries were calculated using both NASS-5 (n=7) and CASS-4 (n=4) after one Mg co-precipitation experiment. The shaded area corresponds to the range of yields calculated for the REEs, from ~ 72 % for Tb to 93 % for Yb, with a mean recovery of 83 ± 14% (dashed line). Error bars represent 1 standard deviation.

图2。共沉淀镁共沉淀过程中的产量。

平均%的回收率计算使用两个NASS-5(= 7)和CASS-4组(n =4)后1个Mg共沉淀实验。的阴影区域对应的范围内的稀土元素的方法计算的产量,从?72%为Tb的关于Yb的93%,具有平均回收率为83±14%(虚线)。误差棒代表1个标准差。

Figure 3. Post-Archean Australian Shales (PAAS)-normalized (Taylor and McClennan, 1985 [29]) REE patterns for NRCC water reference materials (NASS-5, CASS-4) and in house coastal seawater Dellec SW. Note that the Sm anomaly observed in NASS-5 and CASS-4 does not correspond to a natural oceanic feature, but reflects instead contamination during reference material preparation [25].

图3。澳大利亚后太古代页岩(PAAS)标准化(泰勒和McClennan的,1985[29]),REE为的NRCC水的参考材料(NASS-5,CASS-4)和内部的沿海海水Dellec SW模式。注意观察NASS-5和CASS-4,SM异常不对应于一个天然的海洋功能,但反映,而不是参考材料制备过程中的污染[25]。

附原文:

Determination of rare earth elements and other trace elements

(Y, Mn, Co, Cr) in seawater using Tm addition and Mg(OH)2

co-precipitation

Nicolas Freslona, b, c, Germain Bayona, *, Dominique Birota, Claire Bollingerb, c, Jean Alix Barratb, c

a Département Géosciences Marines, IFREMER, 29280 Plouzané, France

b Université Européenne de Bretagne, 35000 Rennes, France

c CNRS UMR6538, IUEM, Université de Brest, 29280 Plouzané, France

*Corresponding author : G. Bayon, Tel.: +33 2 98 22 46 30; fax: +33 2 98 22 45 70, email address: gbayon@ifremer.fr

Abstract:

This paper reports on a novel procedure for determining trace element abundances (REE and Y, Cr, Mn, Co) in seawater by inductively coupled plasma sector field mass spectrometry (ICP-SFMS). The procedure uses a combination of pre-concentration using co-precipitation onto magnesium hydroxides and addition of thulium spike. The validity of the method was assessed onto 25 ml volumes of certified reference materials (NASS- and CASS-4) and in house seawater standard. Procedural blanks were determined by applying the same procedure to aliquots of seawater previously depleted in trace elements by successive Mg(OH)2 co-precipitations, yielding estimated contributions to the studied samples better than 1.1% for all elements, with the exception of Cr (<3.3%) and Co (up to 8%). The reproducibility of the method over the six month duration of the study was smaller than 11% RSD for all the studied elements. Results obtained for NASS-5 and CASS-4 agree well with published working values for trace elements.

Keywords: Trace elements; Rare earth elements (REE); Seawater; Mg(OH)2 co-precipitation; ICP-MS; Thulium

2

1. Introduction

During the last decade, there has been increased interest in determining the global distribution of dissolved trace elements in the ocean and understanding the processes that control their concentrations in seawater. This major community effort, which recently led to the establishment of an ambitious international sampling program (GEOTRACES), requires the use of accurate and rapid analytical techniques for the measurement of key trace elements in seawater.

In recent years, inductively coupled plasma mass spectrometry (ICP-MS) has become the method of choice for determining trace element abundances in the ocean. ICP-MS techniques are rapid, highly sensitive and exhibit very low detection limits, thereby allowing simultaneous multi-element determination of seawater samples over a wide range of concentration (down to sub ng.kg-1 levels) with high sample throughput. Due to the presence of salts (around 35g.kg-1) and to the relatively very low trace element contents in the ocean, the analysis of seawater samples by ICP-MS typically requires an initial step of preconcentration/matrix reduction. A number of methods have been successfully developed in the past for preconcentrating trace

elements and separating the salt matrix prior to ICP-MS analysis (e.g. separation using chromatography [1], solid phase extraction [2], liquid-liquid extraction [3, 4], ion exchange resins [5-7], electrochemical deposition [8], or co-precipitation). For instance, co-precipitation techniques involve the precipitation of solid-phases (typically hydroxides), which act as selective scavengers for a number of dissolved species naturally present in seawater, thereby leading to significant trace element preconcentration from the seawater matrix. Various examples of co-precipitation methods can be found in the literature, including co-precipitation onto gallium hydroxides [9], iron hydroxides [10-12], magnesium hydroxides [13-17], or onto other mineral phases [18].

Trace element concentrations in seawater can be determined by ICP-MS through external calibration, using certified reference materials or multi-elemental reference standard solutions. Isotope-dilution (ID) ICP-MS techniques are also particularly well suited for measuring high-precision trace element concentrations in seawater. Although ID-ICP-MS has been mainly applied to the measurement of single elements in seawater [19-21], a few studies have also reported applications for multi-element determination [13,17,22]. For example, Shaw et al (2003) [13] used a mixed spike cocktail (142Ce, 145Nd, 161Dy, 171Yb) to determine REE concentrations in seawater samples after Mg(OH)2 co-precipitation. Saito and Schneider (2006) [17] also investigated the suitability of the Mg co-precipitation method for determining Fe, Mn and Co abundances in seawater by ID-ICP-MS. In addition to providing precise results, one major advantage of using ID techniques for quantifying trace element abundances in seawater is that they do not require quantitative recovery during sample preparation.

Recently, a novel method was developed at IFREMER for quantifying trace element abundances in seawater by ICP-MS, which involved pre-concentration using Fe co-precipitation and addition of a Tm spike [10]. The addition of Tm spike in the samples prior to co-precipitation produces a Tm anomaly in the resulting chondrite-normalized REE patterns, which can be used to determine the Tm concentration in the sample solutions and serves as internal standard for the remaining elements [23,24]. This method was shown to be well suited for the determination of precise and accurate concentrations for REE, Y, V, Hf, Zr and Th in seawater. However, the presence of relatively high blank levels (e.g. up to 7 pg for light REEs), due to the addition of Fe for co-precipitation, required analysis of large volume samples (100 ml) and prevented accurate determination of key trace elements (e.g. Mn, Co, Cr, Ni, Cu, Sc).

In this study, we have investigated the suitability of combining the Tm addition method with Mg(OH)2 co-precipitation for determining trace element abundances in seawater. The recommended procedure reported in this study allows simultaneous determination of the REEs + Y and a few other trace elements (Cr, Co, Mn) in small volume (25ml) seawater samples.

3

2. Experimental

2.1. Reagents

All sample preparations were conducted in a Class 1000 (ISO 6) clean laboratory. Upon opening, chemical solutions were stored within a Class 100 laminar flow bench (ISO 5). Deionized water purified with a Milli-Q system (Millipore?) at 18.2 MΩ (herein referred to as MQ-H2O) was used for material cleaning and acid dilutions. Polypropylene centrifuge tubes and disposable pipette tips were pre-cleaned thoroughly using diluted HNO3 acid solutions and MQ-H2O. Nitric acid solutions (commercial grade, Merck) were distilled three times using a sub-boiling system. Optima ammonia solution (20-22%) from Fisher Scientific? (Loughborough, UK) and a thulium mono-elementary solution (custom grade, CGTM1-1, Inorganic Ventures Inc.) were used for co-precipitation experiments. Others mono-elementary solutions (custom grade, CGxx1-1, Inorganic Ventures Inc., where xx stands for: Y, Zr, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb, Lu, Hf, Th, U, Sc, Ti, V, Cr, Mn, Co, Ni, Cu, Zn or Cd) were also used for recovery calculations.

2.1. Seawater samples

An in house seawater standard (Dellec SW) was used for method development and blank preparation. Dellec SW is a coastal surface seawater collected off Brittany (NO France) in acid-cleaned 15-L polyethylene jerry-can like containers, filtered through 0.45μm cellulose membrane filters (Whatman?, Dassel, Germany) an d acidified to ~ pH 1.5 using sub-boiled concentrated HNO3. Two certified reference materials (CRMs) purchased from the National Research Council of Canada (NRCC) were analyzed to validate our procedure: CASS-4 (nearshore seawater) and NASS-5 (seawater). These reference materials are certified for a wide range of trace elements (e.g. As, Cd, Cr, Co, Cu, Fe, Pb, Mn, Mo, Ni, U, V, Zn), and are now relatively well characterized for the REEs [5,10,25,26]. In addition to these two CRMS, a certified rock standard (basalt BHVO-2, USGS) was also used to correct for instrumental drift and calibration purpose.

2.3. Procedural blanks

For blank determination, a known weight of Dellec SW (about 25 g) was transferred into a cleaned 50 ml polypropylene centrifuge tube. A v olume of 600 μl of 20-22% NH3 solution (aqueous NH3) was added to the tube to increase the pH to ~ pH 9.5, which led to precipitation of magnesium hydroxides. The tube was shaken and allowed to rest for 2-3 minutes, before centrifugation during 5 minutes at 3800 rpm. The supernatant was then transferred into a cleaned 50 ml tube, prior to addition of 100μl of aqueous NH3 and centrifugation (5 minutes / 3800 rpm). This step was repeated three times using 80, 60 and 50μl of aqueous NH3 solution, respectively, to form successive Mg(OH)2 precipitates. A final (sixth) step of co-precipitation was attempted, but with no success (i.e. no formation of Mg(OH)2 precipitate). At this stage, however, it is very likely that most of the magnesium initially present in the sample had been already removed during the first five co-precipitations. Prior to measurement by ICP-SFMS, the five successive residues of Mg(OH)2 precipitate were dissolved in 300μl of 20% (v/v) sub-boiled HNO3 solution, quantitatively transferred into a 15 ml cleaned polypropylene tube and diluted with 2,700μl MQ-H2O. The efficiency of successive co-precipitations in scavenging trace elements from a seawater

sample was assessed by analysing replicate series of these five residues of Mg(OH)2 precipitate (see Fig. 1).

2.4. Sample preparation

A known weight of sample (about 25 g) was transferred into a pre-cleaned 50 ml polypropylene centrifuge tube, spiked with a known weight (about 50 mg) of Tm solution (957.3 ng.kg-1) and shaken. The mixture was then allowed to equilibrate for 15 minutes. Magnesium hydroxides were formed by increasing the pH of the solution to ~ pH 9.5, through stepwise addition of aqueous NH3. For each sample, an initial 25-ml aliquot was first used to determine the minimum volume of ammonia required to form Mg(OH)2 precipitates. For these ‘test’ samples, 250μl of aqueous NH3 solution was first added to the sample, followed by 10μl successive increments until a precipitate was detected. Then, considering v - the volume of aquaeous NH3 added to any sample to obtain Mg(OH)2 precipitates, a volume v –20 μl of aqueous NH3 solution was added into a 50 ml polypropylene tube containing another 25 ml aliquot of the same sample. The tube was shaken and left 2-3 minutes to equilibrate before centrifugation (5 minutes / 3800 rpm). The supernatants were discarded and, prior to ICP-SFMS analysis, the Mg(OH)2 residues were dissolved in ultra-pure diluted HNO3 solutions (see section Procedural blanks).

2.5. Instrumentation

The analyses were performed at the P?le Spectrométrie Océan (Brest, France) on a Element2 ICP-SFMS (Thermo Electron, Bremen, Germany) equipped with an ASX 100 auto-sampler (CETAC Technologies, Omaha, NE, USA). The operating conditions and measurement parameters are given in Table 1. Solutions were introduced via a Teflon? 100 μl nebulizer and a quartz dual cyclonic spray chamber (ESI). A quartz injector and a set of nickel sampler and skimmer cones were used during the course of this study. The Element2 was operated in low (LRM, m/Δm app rox. 300) and medium (MRM, m/Δm=4500) resolution modes, depending on the required sensitivity and potential interferences for each element. Measured isotopes in LRM were 89Y, 90Zr, 91Zr, 97Mo, 135Ba, 139La, 140Ce, 141Pr, 143Nd, 146Nd, 147Sm, 149Sm, 151Eu, 157Gd, 159Tb, 163Dy, 165Ho, 167Er, 169Tm, 174Yb, 175Lu, 177Hf, 178Hf, 232Th and 238U. In MRM, 45Sc, 47Ti, 51V, 52Cr, 55Mn, 59Co, 60Ni, 63Cu, 66Zn, 110Cd, 111Cd isotopes were measured. Masses were scanned in the E-scan and bi-scan modes.

2.6. Interference corrections

Polyatomic oxide and hydroxide interferences on the rare earth elements (REE) were corrected using oxide formation rates determined by analyzing solutions of MQ-H2O, Ba+Ce, Pr+Nd and Sm+Eu+Gd+Tb at the beginning of each measurement session [23,24]. Oxide formation rates during the course of this study were generally ~0.1% for BaO+/Ba+, <0.1% for CeOH+/Ce+ and ~3% for PrO+/Pr+. Barium (135Ba16O+) and 141Pr16O+ interferences on 151Eu and 157Gd, respectively, were always lower than 20% for all the studied samples. Neodymium oxide (143Nd16O+) interference accounted for less than 10% of the measured 159Tb signals. All other interferences were negligible (less than 3%).

2.7. Calculation

Elemental concentrations were calculated using the Tm addition method [10,24]. Details on the calculations can be found in Bayon et al. (2009) [23]. Briefly, for each sample, elemental concentrations can be calculated using the sample mass, the amount of Tm added, and by calibrating the raw data acquired during the measurement session against an unspiked (no added Tm) BHVO-2 reference solution (diluted ~ 10,000 times), run after every three samples to correct for the instrumental drift. The BHVO-2 values used for the calculations are given in Bayon et al. (2011) [10].

3. Results and discussion

3.1. Effect of successive Mg(OH)2 co-precipitations on trace element scavenging

The efficiency of successive co-precipitations in scavenging trace elements from a seawater sample (Dellec SW) is illustrated in a graph representing measured ICP-MS intensities (cps) versus the number n of successive co-precipitations (Fig. 1). The measured intensities in the residual Mg hydroxide precipitates decrease significantly during the first four co-precipitations (e.g. down to ~ 1000 cps for Y and Zr, to ~ 100 cps for La, Ce, Th, Cr and Mn, and to ~ 10 cps for all other elements), clearly showing that the studied trace elements were efficiently removed from the initial solutions. With the exception of a few elements (Th, Co, Y, Zr), the intensity levels measured after four successive co-precipitations for each element are 1) very similar to those obtained for the fourth Mg-precipitates, and 2) comparable to background levels (measured intensities for 2% (v/v) ultra pure HNO3 solution). Taken together, this indicates that the supernatant left after four successive co-precipitations has been quantitatively depleted in most of the trace elements of interest here, and hence can be considered as suitable for providing an estimate of the total procedural blank in this study.

3.2. Limits of detection and method blanks

Our best estimates for the method blanks and the detection limits for our procedure are listed in Table 2. Detection limits were calculated as three times the standard deviation of a series of 24 procedural blanks. The blank levels were < 1 pg for all REE, Hf and Th, and < 6 pg for Y and Zr. Average blanks were higher for Co (20 pg), Mn (26 pg) and Cr (92 pg). Average blank contributions to the studied seawater standards were negligible for Tm and Mn (<0.1%), and always below 1% for Y+REE, with the exception of Eu (1.1% for CASS-4 and Dellec SW) and Ho (1.4% for CASS-4; 1.2% in Dellec SW). Average blank contributions were slightly higher for Hf, Zr, and Th (< 3%), for Cr (< 4%), and for Co (<8%).

3.3. Co-precipitation yields

An important requirement prior to using the Tm addition method for calculating elemental abundances in seawater samples is that the elements under interest must be scavenged at levels similar to Tm during Mg co-precipitation (i.e. similar extraction yields). To estimate the co-precipitation yields of our procedure, we calculated elemental concentrations for a series

6

of CRM samples (n = 11) using external calibration, and compared the obtained data to certified values (for Mn, Cr and Co), or recently published high quality values [5,10,13,25,26]. The calibration curve used for calculating concentrations in the studied solutions was derived from the analysis of Mg(OH)2 residues, co-precipitated from aliquots of seawater samples previously depleted in trace elements by successive co-precipitations (see procedure described in section 2.3) and spiked with various amounts of a multi-element homemade stock solution.

The calculated co-precipitation yields are displayed in Fig. 2. Note that co-precipitation recoveries were not determined for Cr. The calculated recoveries of the REEs range from ~ 72 % (for Tb) to 93 % (for Yb). All REE+Y exhibit reproducible co-precipitation yields (mean recovery of 83 ± 14%), which are within error, or close (for Tb, Yb and Lu), to those calculated for Tm (82 ± 5%). In agreement with Shaw et al. (2003) [13], this suggests that Mg co-precipitation does not lead to any significant fractionation amongst the REEs. Importantly, this also validates the use of our Tm addition method for determining REE+Y abundances in seawater samples after Mg co-precipitation.

In contrast to the REEs, co-precipitation recoveries calculated for all other studied elements differed from those for Tm. Zirconium and Hf were removed almost quantitatively during co-precipitation (i.e. ~ 100% recovery), whereas Th was less efficiently scavenged from the initial seawater solutions (~ 60%). Importantly, the co-precipitation recoveries of these elements were not reproducible (standard deviation 1s > 15%), showing clearly that our procedure is not well suited for accurate determination of Zr, Hf and Th abundances in seawater. In contrast, co-precipitation yields for Co and Mn, were higher than Tm (i.e. average recovery of 106% and 96%, respectively), but relatively reproducible (respectively 7% and 5% RSD). While the high scavenging efficiency of Mn during Mg(OH)2 co-precipitation had already been reported previously by Saito and Schneider [17], the co-precipitation yields calculated for Co in our study were significantly higher than those estimated in this earlier work. One possible explanation accounting for the observed differences in cobalt scavenging could be that the apparent recovery efficiencies were calculated using different approaches in the two studies: i.e. direct analyses of certified reference materials (our study), and additions of a mixed (Fe, Mn, Co) standard solution to dissolved Mg(OH)2 samples [17].

3.4. Precision and accuracy – Application to the analysis of NASS-5 and CASS-4

The analytical results for the natural water CRMs used in this study (NASS-5 and CASS-4) and our in house seawater (Dellec SW) are listed in Table 2, together with certified values (for Mn, Co and Cr) and selected literature data (for REE+Y). For each of the three seawater standards, the data presented in Table 2 correspond to the mean values ± 1 standard deviation, acquired over a period of about 6 months. The precision on our series of replicate measurements (n = 17 for NASS-5; n = 11 for CASS-4; n = 20 for Dellec SW) is also expressed as the relative standard deviation (RSD). Note that the elements reported in Table 2 correspond to those that were analysed successfully during our co-precipitation experiments. Other elements that were measured but not reported (Mo, Ba, U, Sc, Ti, V, Ni, Cu, Zn, Cd), presented a bad

reproducibility (RSD>15%) and/or error compare to reference value were superior to 15%.

For the REEs, the accuracy of our procedure can be assessed by comparing the obtained Post-Archean Australian shale (PAAS)-normalized values to recently published high quality reference data (Fig. 3). Our measured concentrations for REE + Y are in agreement with values obtained after other pre-concentration methods prior to analysis (e.g. iron co-precipitation [10], solvent extraction [25], chelating resin [5,26]). With few exceptions (i.e. La and Eu), our data agree within 10% error with those obtained using the Tm addition method

7

and iron co-precipitation [10], and liquid-liquid extraction [25]. Our data for La and Eu were slightly lower (11.8% for NASS-5) and higher (11.9% for CASS-4) than those reported after Fe-coprecipitation by Bayon et al. (2011) [10], respectively. One possible explanation for these higher Eu values would be that we under-corrected the contribution of the 135Ba16O isobaric interfence to the 151Eu signal. However, the efficiency of the Ba separation from the precipitate was significantly improved during Mg(OH)2 precipitation compared to the Fe-coprecipitation procedure, as already discussed by Shaw et al. (2003) [13]. This is shown clearly by the much lower Ba/REE ratios in CASS-4 and NASS-5 (i.e. Ba/Eu cps ratios of ~ 8 after Mg-coprecipitation and ~ 100 after Fe-coprecipitation; results not shown here), which suggests that our new Eu values for these reference materials may be more accurate than those obtained by Bayon et al. (2011) [10]. Over the 6-month period of measurement, the precision for the REEs was always better than 10% for the three studied seawater standards (Table 2), with the exception of Eu (14% RSD) and Tb (11% RSD) in CASS-4.

Our measured concentrations for Mn and Co agree well (within 10%) with the CRM certified values: 954 ± 51 ng.kg-1 and 2587 ± 192 ng.kg-1 for Mn in NASS-5 and CASS-4 (certified values: 897 ± 57 ng.kg-1 and 2715 ± 190 ng.kg-1, respectively); 10 ± 1 ng.kg-1 and 23 ± 2 ng.kg-1 for Co in NASS-5 and CASS-4 (certified values: 10 ± 3 ng.kg-1 and 25 ± 3 ng.kg-1, respectively). The precisions for these three elements were better than 10% (RSD), with the exception of Co in CASS-4 (11%). This provides assurance that these two elements can be successfully measured in seawater samples using our recommended procedure, despite the fact that they exhibit co-precipitation yields slightly different than those for the REEs.

Similarly, our measured concentration for Cr in NASS-5 (110 ± 7 ng.kg-1) is in agreement with the certified value (107 ± 15 ng.kg-1) and other published high-quality Cr data [27, 28]. Additional analyses would be needed to further validate whether total Cr in seawater can be routinely measured using our recommended procedure (e.g. determination of coprecipitation yields, analyses of other CRMs). However, the evidence that the long-term reproducibility obtained on our Cr measurements (~6 % RSD for NASS-5) is similar to the precision achieved using ID- ICP-SFMS (~ 5 % RSD; [28]) suggests that our method is well-suited for determination of Cr abundances in seawater.

Conclusions

To summarize, we showed that the Mg coprecipitation technique combined with addition of a Tm spike allows simultaneous determination of the REEs and other trace elements (Y, Mn, Co, Cr) in seawater by ICP-SFMS. Our recommended procedure provides low blanks (mostly < 1% for the REEs, Y and Mn, and < 5% for Cr and Co) and achieves a good reproducibily for 25-mL samples (typically lower than 10% over the six-month duration of the experiments, with the exception of Eu 14%). In addition, its short preparation time (about 10 minutes) makes it particularly well-suited for high sample throughput and routine measurements of seawater samples.

Acknowledgements

The authors are grateful for support, help and advice from Emmanuel Ponzevera, Yoan Germain (Marine Geosciences department, IFREMER), Olivier Rouxel and Fanny Chever (IUEM, Brest).

8

References

[1] S.P. Verma, E. Santoyo, Geostand. Geoanal. Res. 31 (2007) 161-184

[2] M.L. Firdaus, K. Norisuye, T. Sato, S. Urushihara, Y.Nakagawa, S. Umetani, Y. Sohrin, Anal. Chim. Acta. 583 (2007) 296-302

[3] M.B. Shabani, T. Akagi, H. Shimizu, A. Masuda, Anal. Chem. 62 (1990) 2709-2714

[4] G.J. Batterham, N.C. Munksgaard, D.L. Parry, J. Anal. At. Spectrom. 12 (1997) 1277-1280

[5] Y. Zhu, A. Itoh, E. Fujimori, T. Umemura, H. Haraguchi, Bull. Chem. Soc. Jpn. 78 (2005) 659-667

[6] T. Yabutani, S. Ji, F. Mouri, H. Sawatari, A. Itoh, K. Chiba, H. Haraguchi, Bull. Chem. Soc. Jpn. 72 (1999) 2253-2260

[7] R.K. Katarina, T. Takayanagi, K. Oshita, M. Oshima, S. Motomizu, Bull. Chem. Soc. Jpn. 24 (2008) 1537-1544

[8] W.J. Clark, S.H. Park, D.A. Bostick, D.C. Duckworth, G.J. van Berkel, Anal. Chem. 78 (2006) 8535-8542

[9] T. Akagi, K. Fuwa, H. Haraguchi, Anal. Chim. Acta. 177 (1985) 139-151

[10] G. Bayon, D. Birot, C. Bollinger, J. A. Barrat, Geostand. Geoanal. Res. 35 (2011) 145-153

[11] C.L. Chou, J.D. Moffatt, J. Fresenius, Anal. Chem. 368 (2000) 59-61

[12] Y. Zhu, K. Inagaki, H. Haraguchi, K. Chiba, J. Anal. At. Spectrom. 25 (2010) 364-369

[13] T.J. Shaw, T. Duncan, B. Schnetger, Anal. Chem. 75 (2003) 3396-3403

[14] J. Wu, E.A. Boyle, Anal. Chem. 69 (1997) 2464-2470

[15] M. Grotti, F. Soggia, F. Ardini, R. J. Frache, Anal. Spectrom. 24 (2009) 522-527

[16] J. Wu, Mar. Chem. 103 (2007) 370-381

[17] M.A. Saito, D.L. Schneider, Anal. Chim. Acata 565 (2006) 222-233

[18] P. Grindberg, S. Willie, R.E. Sturgeon, J. Anal. At. Spectrom. 20 (2005) 717-723

[19] B.A. Mc Kelvey, K.J. Orians, Mar. Chem. 60 (1998) 245-255

[20] J. Wu, E.A. Boyle, Anal. Cim. Acta.(1998) 183-191

[21] Y. Zhu, K. Inakagi, K. Chiba, J. Anal. At. Spectrom. 24 (2009) 1179-1183

[22] M.P. Field, R.M. Sherrell, Anal. Chem. 70 (1998) 4480–4486

[23] G. Bayon, J.A. Barrat, J. Etoubleau, M. Benoit, S. Révillon, C. Bollinger, Geostand. Geoanal. Res. 32 (2009) 51-62.

[24] J.A. Barrat, F. Keller, J. Amossé, R.N. Taylor, R.W. Nesbitt, T. Hirata, Geostand. Newsl. 20 (1996) 133-139

[25] M.G. Lawrence, B.S. Kamber, Geostand. Geoanal. Res. 31 (2007) 95-103

[26] D. Rahmi, Y.B. Zhu, E. Fujimori, T. Umemura, H. Haraguchi, Talanta 612 (2007) 600-606

[27] L. Yang, S. Willie, R.E. Sturgeon, J. Anal. At. Spectrom. 24 (2009) 958-963

[28] I. Sánchez Trujillo, E. Vereda Alonso, M.T. Siles Cordero, J.M. Cano Pavón, A. García de Torres, J. Anal. At. Spectrom. 25 (2010) 1063-1071

[29] S.R. Taylor, S.M. McCLennan, The Continental Crust: its Composition and Evolution. Blackwell, Oxford, 1985.

《地球化学》练习题2剖析

恩《地球化学》练习题 第一章太阳系和地球系统的元素丰度(答案) 1.概说太阳成份的研究思路和研究方法。 2.简述太阳系元素丰度的基本特征。 3.说说陨石的分类及相成分的研究意义. 4.月球的结构和化学成分与地球相比有何异同? 5.讨论陨石的研究意义。 6.地球的结构对于研究和了解地球的总体成分有什么作用? 7.阐述地球化学组成的研究方法论。 8.地球的化学组成的基本特征有哪些? 9.讨论地壳元素丰度的研究方法。 10.简介地壳元素丰度特征。 11.地壳元素丰度特征与太阳系、地球对比说明什么问题? 12.地壳元素丰度值(克拉克值)有何研究意义? 13.概述区域地壳元素丰度的研究意义。 14.简要说明区域地壳元素丰度的研究方法。 15.岩浆岩中各岩类元素含量变化规律如何? 16.简述沉积岩中不同岩类中元素含量变化规律。 第二章元素结合规律与赋存形式(答案) 1.亲氧元素和亲硫元素地球化学性质的主要差异是什么? 2.简述类质同像的基本规律。 3.阐述类质同像的地球化学意义。 4.简述地壳中元素的赋存形式及其研究方法。 5.举例说明元素存在形式研究对环境、找矿或农业问题的意义。 6.英国某村由于受开采ZnCO3矿的影响,造成土壤、房尘及饮食摄入Cd明显高于其国标,但与未受污染的邻村相比,在人体健康方面两村没有明显差异,为什么? 第三章自然界体系中元素的地球化学迁移(答案) 1.举例说明元素地球化学迁移的定义。 2.举例说明影响元素地球化学迁移过程的因素。 3.列举自然界元素迁移的标志。 4.元素地球化学迁移的研究方法。 5.水溶液中元素的迁移形式有那些?其中成矿元素的主要迁移形式又是什么? 6.解释络离子的稳定性及其在地球化学迁移中的意义。 7.简述元素迁移形式的研究方法。 8.什么是共同离子效应?什么是盐效应? 9.天然水的pH值范围是多少?对于研究元素在水介质中的迁移、沉淀有何意义? 10.举例说明Eh、pH值对元素迁移的影响。 11.非标准电极电位E及环境的氧化还原电位Eh,在研究元素地球化学行为方面有什么作用? 12.试述影响元素溶解与迁移的内部因素。 13.自然界中地球化学热力学体系基本特点是什么? 14.自然体系中哪些特征可作为体系达到平衡态的证据与标志? 15.讨论相律及其应用。

施密特元素分类

元素地球化学分类 yuansu diqiu huaxue fenlei 元素地球化学分类 geochemical classification of the elements 在元素周期表的基础上,结合元素的自然组合及各种地球化学特征,对化学元素进一步的分类。它反映了化学元素在自然界的分布规律及其相互间的共生组合特征与其原子结构的密切关系。元素的地球化学分类较多,被广泛采用的是V.M.戈尔德施密特及A.H.扎瓦里茨基的分类。 戈尔德施密特的分类是以其地球起源和内部构造的假说为基础的,他根据化学元素的性质与其在各地圈内的分配之间的关系,将元素分为4个地球化学组,如图1戈尔德施密特元素地球化学分类图所示。①亲石元素,离子最外层具有2个或8个电子,呈惰性气体型稳定结构,与O、F、CL亲合力强,多组成氧化物或含氧盐,特别是硅酸盐,形成大部分造岩矿物,并主要集中在岩石圈;②亲铜元素,离子最外层具有 18个电子的铜型结构,与S、Se、Te亲和力强,多形成硫化物和复杂硫化物;③亲铁元素,离子最外层具有8~18个电子的过渡型结构,与O及S的亲和力均较弱,主要集中在地球深部的铁镍核中;④亲气元素,为惰性气体,呈原子或分子状态集中在地球的大气圈中。此外,戈尔德施密特还划分出亲生物元素,这些元素多富集在生物圈中。 扎瓦里茨基的分类能够从原子结构这一最本质的原因去理解元素在自然界的分布与组合规律。按这种分类,化学元素被分成 12族(图2扎瓦里茨基元素地球化学分类图):①氢族;②造岩元素族(Li、Be、Na、Mg、Al、Si、K、Ca、Rb、Sr、Cs和Ba);③惰性气体族 (He、Ne、Ar、Kr、Xe、Rn);④挥发分元素族(B、C、N、O、F、P、S、Cl);⑤铁族(Ti、V、Cr、Mn、F e、Co、Ni);⑥稀土稀有元素族 (Sc、Y、Zr、Nb、TR、Hf、Ta等);⑦放射性元素族(Fr、Ra、Ac、Th、Pa、U等);⑧钨钼族 (Mo、Tc、W、Re);⑨铂族(Ru、Rh、Pd、Os、Ir、Pt);⑩硫化矿床成矿元素族 (Cu、Zn、Ge、Ag、Cd、In、Sn、Au、H g、Tl、Pb等);□半金属元素族(As、Sb、Bi、Se、Te、Po);□重卤素元素族(Br、I、At)。 除了上述这些系统的分类外,还有根据特定的地质作用对元素进行地球化学分类的。如在描述岩浆分异结晶作用或部分熔融过程中,把进入结晶相或残留相的称为相容元素,而进入熔体相的称为不相容元素等。 参考书目南京大学地质学系编:《地球化学》(修订本),科学出版社,北京,1979。赵伦山、张本仁编著:《地球化学》,地质出版社,北京,1988。 (王中刚)

元素地球化学

元素地球化学 第一章:导论 ◆地球化学的三个主要分支:①元素地球化学②同位素地球化学③实验地球化学 ◆元素地球化学:是地球化学最主要的分支学科,它通过逐一阐明个别元素的地球化学和宇宙化学特征及其与其它元素的组合关系来研究自然界化学演化规律的学科,是地球化学的传统研究内容和主干学科。它力求完整地了解元素的地球化学旋回及其演化历史和原因,揭示元素含量变化对自然过程的指示意义 ◆元素地球化学主要研究内容和任务: (1)每个或每组化学元素的地球化学性质; (2)元素或元素群在自然界的分布、分配情况; (3)元素相互置换、结合、分离的规律和机制; (4)元素的存在形式、组合特点、迁移条件; (5)每个元素的地球化学旋回及其演化历史和原因 (6)应用于地球资源、环境和材料的研究、预测、开发和保护。 ◆元素地球化学的研究方法: (1)地质研究方法; (2)高灵敏度、高精度、快速和经济的测定和分析手段:ICP-MAS、ICP-AES、X荧光、电子探针等等; (3)各种地球化学模拟实验研究; (4)一些物理化学、热力学等理论的应用; (5)计算机技术在处理大量数据方面的广泛应用。 ◆戈尔德施密特的元素地球化学分类: 亲铁元素Siderophile:富集于陨石金属相和铁陨石中的化学元素。它们与氧和硫的结合能力均弱,并易溶于熔融铁中;在地球中相对于地壳和地幔,明显在地核内聚集。其离子最外层电子数在8~18之间。典型的秦铁元素有镍、钴、金、铂族元素。 亲石元素lithophile:在陨石硅酸盐相中富集的化学元素;在地球中它们明显富集在地壳内,有较大的氧化自由能。在自然界中都以氧化物,含氧盐,特别是硅酸盐的形式出现。如硅、铝、钾、钠、钙、镁、铷、锶、铀、稀土元素等。其离子最外层电子数为2或8。 亲铜元素chalcophile:在陨石硫化物相和陨硫铁(FeS)中富集的化学元素;在自然界中,它们往往易与S2-结合成硫化物和复杂硫化物。如硫、铜、锌、铅、镉、砷、银、硒、碲、锑等。其离子最外层有18个电子。 亲硫元素sulphophile:指不易与氧、氟和氯结合,而易于形成硫化物、硒化物、碲化物、砷化物等矿物的元素。该术语现一般理解为与“亲铜元素”同义,并包括一些亲铁元素。 亲气元素atmophile:组成地球大气圈的主要元素,惰性气体元素,以及主要呈易挥发化合物存在的元素。如氢、氮、碳、氧、及惰性气体元素等。 亲生物元素biophile:集中在有生命的动植物内的元素。C, H , O, N, P, S, Cl, I, (B), (Ca, Mg, K, Na), (V, Mn, Fe, Cu) ◆有关其他元素分类的常用术语: 常量元素:组成物质主要结构和成分的元素,它们常占天然物质总组成的99%以上,并决定了物质的定名和大类划分。 微量元素(trace element, microelement):物质中除了那些构成主要结构格架所必须的元素之外,所有以低浓度存在的化学元素。其浓度一般低于0.1%,在大多数情况下明显低于0.1%而仅达到ppm乃至ppb数量级。 次要元素(minor element):在文献中单独出现时时与微量元素同义;当两者同时出现时,一般指含量为1~5的化学元素。 稀有元素(rare element):在低壳中分布量较低,但易于在自然界高度富集形成较常见的矿物和独立工业矿床的的化学元素。如REE、Nb、Ta、Be、Li、(W)等。 分散元素(dispersed element):在地壳中元素丰度低,并且其离子半径和电荷等化学性质与地壳中的高丰度元素(硅、铝、钙、铁、钾、钠等)相似的一类微量元素。因上述性质,它们在自然界中大多以类质同像置换形式分散存

中国地质大学地球化学习题及答案

中国地质大学《地球化学》练习题及答案 中国地质大学《地球化学》练习题绪论 1. 概述地球化学学科的特点。2. 简要说明地球化学研究的基本问题。3. 简述地球化学学科的研究思路和研究方法。4. 地球化学与化学、地球科学其它学科在研究目标和研究方法方面的异同。第一章太阳系和地球系统的元素丰度 1.概说太阳成份的研究思路和研究方法 2.简述太阳系元素丰度的基本特征.3.说说陨石的分类及相成分的研究意义.4.月球的结构和化学成分与地球相比有何异同?5.讨论陨石的研究意义.6. 地球的结构对于研究和了解地球的总体成分有什么作用?7. 阐述地球化学组成的研究方法论.8. 地球的化学组成的基本特征有哪些?9. 讨论地壳元素丰度的研究方法.10.简介地壳元素丰度特征.11. 地壳元素丰度特征与太阳系、地球对比说明什么问题? 12.地壳元素丰度值(克拉克值)有何研究意义?13.概述区域地壳元素丰度的研究意义.14.简要说明区域地壳元素丰度的研究方法.15.岩浆岩中各岩类元素含量变化规律如何?16.简述沉积岩中不同岩类中元素含量变化规律. 第二章元素结合规律与赋存形式1.亲氧元素和亲硫元素地球化学性质的主要差异是什么? 2.简述类质同像的基本规律. 3.阐述类质同像的地球化学意义. 4.简述地壳中元素的赋存形式及其研究方法. 5.举例说明元素存在形式研究对环境、找矿或农业问题的意义. 6.英国某村由于受开采ZnCO3矿的影响,造成住宅土壤、房尘及饮食摄入Cd明显高于其国标,但与未受污染的邻村相比,在人体健康方面两村没有明显差异。为什么? 第三章水-岩化学作用和水介质中元素的迁移 1.举例说明元素地球化学迁移的定义. 2.举例说明影响元素地球化学迁移过程的因素。 3.列举自然界元素迁移的标志. 4.元素地球化学迁移的研究方法. 5.水溶液中元素的迁移形式有那些?其中成矿元素的主要迁移形式又是什么? 6.解释络离子的稳定性及其在地球化学迁移中的意义. 7.简述元素迁移形式的研究方法. 8.什么是共同离子效应?什么是盐效应?9.天然水的pH值范围是多少?对于研究元素在水介质中的迁移、沉淀有何意义?10.举例说明Eh、pH值对元素迁移的影响. 11.非标准电极电位E及环境的氧化还原电位Eh,在研究元素地球化学行为方面有什么作用?12.试述影响元素溶解与迁移的内部因素。 第四章地球化学热力学和地球化学动力学 1.自然界中地球化学热力学体系基本特点是什么? 2.自然体系中哪些特征可作为体系达到平衡态的证据与标志? 3.讨论相律及其应用。 4.编制相图的原理和方法。 6.简述化学反应制动原理的宏观解释7.简述热力学在地球化学中的应用。8.简述地球化学热力学与地球化学动力学的异同。9. 简述水溶液中元素的迁移方式。第五章微量元素地球化学 1.什么是微量元素地球化学?其研究意义是什么? 2.了解微量元素地球化学的研究思路及研究方法。 3.什么叫微量元素、什么是主量(常量)元素?微量元素的主要存在形式有哪些? 4.阐述能斯特分配定律、能斯特分配系数的概念及其研究意义。 5.稀土元素的主要特点是什么?其在地球化学体系中行为差异主要表现有哪些方面?。 6.讨论稀土元素的研究意义。7.你认为岩浆作用过程中决定元素浓集成矿的主要机制和决定因素是什么?8 根据微量元素的特点,说明那些元素适合于研究沉积岩物源区特征,为什么? 第六章同位素地球化学 1. 同位素地球化学在解决地学领域问题中有何独到之处? 2. 何谓稳定同位素、何谓轻稳定同位素和重稳定同位素。 3. 选择同位素标准样品的条件。 5. 造成稳定同位素组成变化的原因是什么? 6. 放射性同位素年龄测定公式,各符号的含义。

微量元素地球化学在岩石成因和成矿作用中的应用

关于微量元素地球化学的读书报告 (021111班2011100 ---- ---) 微量元素基本概念 微量元素(minor elements) 依不同学者给出了不同的定义。盖斯特(Gast, 1968)定义微量元素“不作作系内任何相主要组份存的非化学计量的分散元素” 。按此定义微量元素是相对的,在一个 体系中为微量元素,而在另一个体系中可能为常量元素。有人从热力学角度来定义微量元素:在 研究的对象中元素的其含量低到可可近似地用稀溶液定律来描述其行为,则该元素可称为微量元 素。一般的,将地壳中除O、Si、Al、Fe、Ca、Mg、Na、K、Ti 等9 种 元素(它们的总重量丰度占99%左右)以外的其它元素统称为微量元素,它们在岩石或矿物中的含量一般在1%或0.1%以下,含量单位常以10-6或10-9表示。 开始的研究主要集中在了解和查明微量元素在陨石、地球及其各层圈以及各类地质体中的分布、丰度及其规律,而后认识到微量元素作为一种示踪剂或指示剂,研究成岩成矿作用,如岩石 类型划分,原岩恢复、成岩成矿的物质来源和物理化学条件微量元素的特殊的地球化学性质,同 时可以利用热力学的有关理论,建立微量元素地球化学模型,对成岩和成矿的熔融和结晶作用过程进行定量理论计算,使微量元素地球化学有自己的特殊的研究方法和理论体系。在地球化学中最大量和最主要的应用集中表现为:利用微量元素的组成、相互关系等特征作为各类岩石、矿石的成因类型的“指纹元素” ,并进一步利用微量元素来探讨和指示地质、地球化学过程。 二微量元素在成岩过程中的化学示踪作用 1.1 微量元素地球化学对和组合关系图解在将微量元素资料用于地球化学问题研究时,常将两个元素的关系、或将两个元素比值的关系、或两组元素和比值的关系进行对比,可统称为微量元素对,或微量元素地球化学对。一般说来,微量元素对常常是地球化学性质相近的元素,如Nb/Ta,Zr/Hf ,Sr/Ba ,Th/U, Cr/Ni ,Cl/Br 等,也可以其中一个是主元素,另一个是与其他化性质相似的微量元素,如K/Rb, Mg/Li ,Ca/Sr ,Fe/V,Al/Ga ,S/Se 等。前述各单个稀土元素比值(如La/Ce )也常 用作元素对。 应该根据研究目的选择不同的元素对。如研究岩浆形成机制和过程鉴别要选择分配性 质相同或相反的元素对,如Ba/Nb, Nb/Th,以及Ce—Ni, Cr - Ta等。要讨论氧化、还原状态,要选择变价元素对,如Fe2+/Fe3+, V3+/V5+,Eu2+/Eu3+,以及Mn/Mg等。要研究岩体剥蚀深度,要选择元素浓度随深变而增减的,如Li/Sc ,Rb/Bi ,Sb/Bi 等。而要进行变质岩原岩恢复,则需选择对变质作用较稳定的元素,如Zr/Ti ,Zr/Ni ,Cr/Ti ,Zr/Mg 等等。有时为了

第五章微量元素地球化学2011

第四章微量元素地球化学 第一节微量元素地球化学基本原理 一、微量元素概念(是相对的概念) 主量元素(主要元素、常量元素):岩石的主要组成部分,含量>0.1wt%,通常用氧化物的重量百分数来表示(wt%); 微量元素(痕量元素、痕迹元素):难以形成独立矿物,浓度<0.1%,通常用ppm或ppt表示。 Gast(1968)对微量元素的定义是:不作为体系中任何相的主要化学计量组分存在的元素。微量元素的另一定义为,在所研究的地球化学体系中,其地球化学行为服从稀溶液定律(亨利定律,Henry’s Law)的元素。 常(主)量和微量元素在自然界中是相对的概念,常因所处的体系不同而相互转化。如Cr在大多数地壳岩石中为微量元素,但在超基性岩中可呈常量元素;Fe在岩石中是常量元素,但在有机物中多为微量元素;Zr在岩石中是微量元素,但在锆石中为常量元素;K在地壳整体中是主量元素,但它在陨石中却被视为微量元素。 在自然界中,主要的常量元素的含量变化范围有限(多小于1个数量级),而微量元素的变化范围较大(常达2个数量级),明显超过常量元素。例如: SiO2在基性、中基性、中酸性和酸性岩浆的平均含量分别约为45、52、65和75 (wt%),其相对变化量为1.7; Rb在基性、中基性、中酸性和酸性岩浆的平均含量分别约为0.2、4.5、100和200 ppm,相对变化量为1000。 二、微量元素的特点 1、微量元素的概念难以用严格的定义进行描述; 2、自然界“微量”元素的概念是相对的,应基于所研究的体系; 3、低浓度(活度)是微量元素的核心特征,在宏观上表现常为不能形成自己的独立矿物(相),近似服从稀溶液定律(亨利定律)。 三、微量元素在共存相中的分配规律 地球化学过程中元素的地球化学行为在实质上表现为,当所在的介质条件发生变化时,其在相关共存的各相(液—固、固—固等)之间发生重新分配过程。自然过程总量趋向于达到不同尺度的平衡,元素在平衡条件下,相互共存各相之间的分配取决于元素及矿物的晶体化学性质(内因)及物理化学条件(外因)。 常量元素——形成独立矿物相,其分配行为受相律的控制,遵循化学计量法则。 微量元素——在自然体系中浓度极低,不能形成以独立矿物。因此,微量元素的分配不受相律和化学计量的限制,而是服从稀溶液定律(即分配达到平衡时,微量元素在各相之间的化学

地球化学知识点整理

地球化学 绪论 1、地球化学的定义: 地球化学是研究地球(包括部分天体)的化学组成、化学作用和化学演化的科学2、地球化学的基本问题:【填空】 (1)质:地球系统中元素的组成 (2)量:元素的共生组合和赋存形式 (3)动:元素的迁移和循环 (4)史:地球的历史和演化 3、地球化学研究思路:【简答】 在地质作用过程中,在宏观地质体变化和形成的同时,亦伴有大量肉眼难以辨别的化学组成变化的微观踪迹,它们包含着重要的定性和定量的地质作用信息,应用现代化学分析测试手段,剖析这些微观踪迹,从而揭示宏观地质作用的奥秘。即“见微而知著”。 第一章地球和太阳系的化学组成 第一节地球的结构和组成 1、地球的圈层结构、主要界面名称: (1)地震波(P波和S波)在地球内部传播速度的变化,反映出地球内部物质的密度和弹性是不均一的。这种不均一性在地球的一定深度表现为突变性质。由此得出,地球内部具有壳层结构的概念,即认为地球由表及里分为地壳、地幔和地核三个部分。界面分别为:莫霍面和古登堡面。 (2)上地壳和下地壳分界面为康拉德面。上地壳又叫做硅铝层,下地壳又叫做硅镁层。大陆地壳由上、下地壳,而大洋地壳只有下地壳。【填空】 2、固体地球各圈层的化学成分特点:(分布顺序) 地壳:O、Si、Al、Fe、Ca 地幔:O、Mg、Si、Fe、Ca 地核:Fe-Ni 地球:Fe、O、Mg、Si、Ni

第二节元素和核素的地壳丰度 1、基本概念:【名词解释】 (1)地球化学体系:我们把所要研究的对象看作是一个地球化学体系,有一定的空间,处于特定的物理-化学状态,并且有一定时间的连续 (2)丰度:研究体系中被研究元素的相对含量 (3)克拉克值:地壳中元素的平均含量 (4)质量克拉克值:以质量计算表示的克拉克值 (5)原子克拉克值:以原子数之比表示的元素相对含量。它是指某元素在某地质体全部元素的原子总数中所占原子个数的百分数。 (6)浓度克拉克值:某一元素在地质体中的平均含量与克拉克值的比值 2、克拉克值的变化规律: (1)递减:元素的克拉克值大体上随原子序数的增大而减小。但Li、B、Be以及惰性气体的含量并不符合上述规律,其丰度值很低。 (2)偶数规则(奥多-哈金斯法则):周期表中原子序数为偶数的元素总分布量大于奇数元素的总分布量,相邻元素之间偶数序数的元素分布量大于奇数元素分布量。 (3)四倍规则(了解): 元素的质量数A除以4,可分为四类:4q+3、4q+2、4q+1、4q 3、“元素克拉克值”研究意义:【简答】 (1)是地球化学研究重要的基础数据 (2)确定地壳中各种地球化学作用过程的总背景 (3)是衡量元素集中、分散及其程度的标尺 (4)是影响元素地球化学行为的重要因素 4、区域元素丰度的研究的意义:【简答】 (1)它是决定区域地壳(岩石圈)体系的物源、物理化学特征的重要基础数据(2)为研究各类地质、地球化学作用、分析区域构造演化历史及区域成矿规律提供重要的基础资料 (3)为研究区域生态环境,为工业、农业、畜牧业、医疗保健等事业提供重要信息

微量元素地球化学的应用

微量元素在成岩成因和成矿成因研究中的应用 姓名:叶勃 学号: 班级024121

微量元素在成岩成因和成矿成因研究中的应用 前言 人类活动所能涉及的地壳主要是由92种化学元素组成.其中元素O、Si、Al、Fe、Ca、Na、K、Mg和Ti九种元素占据地壳和地幔的99%,其余83种元素只占1%,然而正是这1%的元素给人类的发展提供了丰富的物质基础——矿产资源。随着人们对微量元素性质的逐步认识,人们发现微量元素在成岩成因和成矿成因上有重要的作用。这次读书报告,我读了《微量元素地球化学及其应用》(戴塔根刘汉元著)以及相关的文献。 第一章何为微量元素 微量元素是指自然界除了主量元素外,丰度低于0.1%,在体系中不作为任何相的主要成分,浓度低到服从稀溶液定律的元素。在地球化学研究中,习惯上微量元素不记入矿物分子式中。 微量元素与主量元素是相对的,根据研究对象的不同而存在差别。例如,锆石中的Zr通常属于微量元素,但是在锆石中,它属于常量元素。 微量元素存在的三个形式:在矿物快速结晶过程中陷入囚禁带内、在主晶格的间隙缺陷中和在固溶体中以类质同像替代主要元素的原子或离子。 为微量元素地球化学做出最大贡献的人是能斯特,他提出能斯特分配定律,不仅将地学与化学联系起来,更重要的是他将地球化学由定性研究引向定量研究,打开了研究微量元素地球化学的大门。根据能斯特分配定律,我们引进了分配系数为组数i在两相(α和β)之间的质量浓度比值。 同时,因为元素的地球化学,或者行为往往受到多个矿物的影响,通常为矿物集合体,所以,我们引入总分配系数的概念,它是微量元素在各矿物相与熔体间简单分配系数与矿物相含量的加权之和。

地球化学分类基础

地球化学分类的基础是什么,除了本课程中介绍的分类方案,还有什么分类方案? 按照地球形成的一种模型,地球是由成分近似于一般球粒陨石的微行星聚集作用演化而来。这些球粒陨石具有三种不同的相,即金属相、硫化物和硅酸盐相。化学元素在地球中的分布主要根据元素对三种相的亲合力关排布的,这种亲合力由原子的电子排布和化学键性控制。陨石中各相的成分主要是由Fe-Mg-Si-O-S这些元素控制。其他元素的分布实质上就是由它们和这些元素的亲合关系所决定。因此,地球化学元素的分类也是以原子的电子排布和化学键性所导致的元素本身的性质差异为基础进行分类的. 本课程中介绍的分类方案戈尔德施密特的这一经典的元素地球化学分类及名称,直到现在仍被地球化学界广为引用。除此之外,维尔纳斯基、费尔斯曼及施奈德洪等也提出过不同的分类方案,都不及戈氏分类的简洁、实用。 首先是: 查瓦里茨基的元素地化学分类反映了元素在成岩、成矿作用中的意义。他把元素分成十二族,但对某些微量元素属性仍不够准确,使用中亦有繁琐之嫌。扎瓦里茨基的分类能够从原子结构这一最本质的原因去理解元素在自然界的分布与组合规律。按这种分类,化学元素被分成12族: 1)氢族; 2)造岩元素族(Li、Be、Na、Mg、Al、Si、K、Ca、Rb、Sr、Cs和Ba); 3)惰性气体族(He、Ne、Ar、Kr、Xe、Rn); 4)挥发分元素族(B、C、N、O、F、P、S、Cl); 5)铁族(Ti、V、Cr、Mn、Fe、Co、Ni); 6)稀土稀有元素族(Sc、Y、Zr、Nb、TR、Hf、Ta等); 7)放射性元素族(Fr、Ra、Ac、Th、Pa、U等); 8)钨钼族(Mo、Tc、W、Re); 9)铂族(Ru、Rh、Pd、Os、Ir、Pt); 10)硫化矿床成矿元素族(Cu、Zn、Ge、Ag、Cd、In、Sn、Au、Hg、Tl、Pb等); 11)半金属元素族(As、Sb、Bi、Se、Te、Po); 12)重卤素元素族(Br、I、At)。 其次是除了上述这些系统的分类外,还有根据特定的地质作用对元素进行地球化学分类的。如在描述岩浆分异结晶作用或部分熔融过程中,把进入结晶相或残留相的称为相容元素,而 进入熔体相的称为不相容元素等。 最后是戚长谋的“元素地球化学分类探讨”中提出的分类表包括亲石元素、亲氧元素、亲硫元素、阴离子及两性元素和氢及惰性气体元素五个类。 (1)亲石元素:就具有与硅酸根或碳酸根结合倾向的元素。因其为造岩矿物的主要成分, 故仍采用“亲石”术语。本类元素包括周期表左侧的碱金属和碱土金属两个化学族。s电子构型。X=0.7—1.5。 本类元素与硅酸根和碳酸根结合的倾向具有选择性。碱金属和碱土金属可分别与不同结构的硅酸根结合形成各类硅酸盐, 而与碳酸根结合的元素则为碱土金属Mg、Ca、Sr 、Ba等。(2)亲氧元素: 具有与氧结合倾向的元素, 包括呈氧化物(如TiO2)或酸根(如SiO44-、CO32-)两种状态。这一定义严格地与戈氏“亲石”的概念相区别。分类表中包括碱土金属右侧的第三、第四、第五副化学族和Cr、W、U、Mn、Fe及Sn等。p及d电子构型, X=1.3—2.2 。

微量元素地球化学期末作业培训课件

西藏阿里多龙地区中侏罗统碎屑沉积岩的地球 化学特征及其构造环境分析 学号:120110100 姓名:胡维云专业:构造地质学 前言 班公湖—怒江成矿带西段位于西藏自治区西北部的阿里地区境内,跨班公湖—怒江缝合带南北两侧,由于仅开展过 1∶25 万区域地质调查、1∶20万区域化探等少量基础地质工作,是西藏地质工作程度最低的地区之一。近年来该成矿带内资源评价工作取得了突出的进展,多龙超大型斑岩铜金矿床和嘎尔穷、嘎拉勒、弗野、材玛等大型矽卡岩型铜铁多金属矿床的相继发现与评价,揭示出班公湖—怒江成矿带成矿条件优越,找矿潜力巨大。关于班公湖—怒江结合带所代表的特提斯洋盆的性质,打开、闭合的时限和多龙大型矿集区的构造背景、成矿作用,不同的学者存在很大的争议。目前,己有许多资料证明了该带代表了一个已消失的具有一定规模的洋壳盆地。王恒忠等(2005)认为班公湖--怒江缝合带内的早白奎世OIB型火山岩是班公湖—怒江洋盆演化晚期的洋岛(塔仁本区早白垩世OIB型玄武岩(主要依据于上覆灰岩中化石时代));而张玉修等(2004)研究认为该套玄武岩是早白垩世冈底斯弧弧后盆地的产物。 一、研究目的及意义 拟通过研究多龙地区中侏罗统地层的岩石类型及组合特征和岩石地球化学特征,分析该地区中侏罗统地层形成的大地构造环境,为正确认识多龙超大型斑岩铜金矿床的成矿地质背景和结合带的演化提供了新的线索。 二、研究区地质背景 构造位置上,多龙地区处于班公湖—怒江缝合带北侧, 羌塘地块的南缘;地理位置上处于西藏自治区阿里地区。该区构造以断裂为主,呈近东西向带状断续展布。断裂构造主要表现为一系列走向近东西向且大致平行的北倾逆冲断层,并控制着地层和岩浆岩的分布。沿构造-岩浆带,大规模的岛弧火山活动发生在中—晚侏罗世,形成燕山早期陆缘火山弧,为一套含大量火山碎屑岩的以安山质为主的玄武—安山—流纹岩组合,火山作用晚期岩浆成分向碱性演化,以陆相中心式喷发为主,兼具熔岩溢流(西藏自治区区域地质志,2000)。岩浆的深成侵入作用发生在早白垩世至晚白垩世早期,以中酸性幕式侵入为特点,岩体一般呈岩珠或小岩基沿东西向呈带状分布,岩性主要有石英闪长岩、花岗闪长岩、二长花岗岩、似斑状花岗岩及花岗斑岩,年龄在70—140Ma之间(西藏自治区区域地质志,2000)。研究区地层主要为晚三叠统的日干配错组、中侏罗统的曲色组一段、色哇组、,早白垩统的美日切组,新近系中新统的康托组、更新统和全新统。地层属羌塘—昌都地层区内的羌南地层分区之多码分区,出露宽度大于10km。 三、研究依据 据现有资料研究表明:砂岩的TFe2O3+MgO、TiO2含量,以及Al2O3/SiO2、K2O/Na2O 和A12O3/(CaO+Na2O)等比值具有显著的构造背景差异,因而成为其形成的大地构造环境判别的重要参数(Bhatia,1983)。Roser等人(1986)认为,K2O/Na2O值与SiO2值可有效地示踪砂岩形成构造环境,并编制了构造判断图解。在Bhatia(1983)提出的TiO2-TFe2O3+MgO图解,Roser和Korsch(1988)提出了区分物源区是铁镁质的、中性的或长英质火成岩和石英沉积

地球化学(复习资料)

第一章 1.克拉克值:元素在地壳中的丰度,称为克拉克值。元素在宇宙体或地球化学系统中的平均含量称之为丰度。丰度通常用重量百分数(%),PPM(百万分之一)或g/t表示。 2.富集矿物:指所研究元素在其中的含量大大超过它在岩石总体平均含量的那种矿物。 3.载体矿物:指岩石中所研究元素的主要量分布于其中的那种矿物。 4. 浓集系数=工业利用的最低品位/克拉克值。为某元素在矿床中可工业利用的最低品位与其克拉克值之比。 5.球粒陨石:是石陨石的一种。(约占陨石的84%):含有球体,具有球粒构造,球粒一般为橄榄石和斜方辉石。基质由镍铁、陨硫铁、斜长石、橄榄石、辉石组成。划分为: E群——顽火辉石球粒陨石,比较稀少;O群——普通球粒陨石: H亚群—高铁群,橄榄石古铜辉石球粒损石;L亚群—低铁群,橄榄紫苏辉石球粒陨石;LL亚群—低铁低金属亚群;C群——碳质球粒陨石,含有碳的有机化合物和含水硅酸盐,如烷烃、芳烃、烯烃、氨基酸、卤化物、硫代化合物等。为研究生命起源提供重要信息。分Ⅰ型、Ⅱ型和Ⅲ型。Ⅰ型其非挥发性组成代表了太阳系星云的非挥发性元素丰度。 6.浓度克拉克值=某元素在地质体中的平均含量/克拉克值,反映地质体中某元素的浓集程度。 1.陨石在地化研究中的意义:(一)陨石的成分是研究和推测太阳系及地球系统元素成分的重要依据:(1)用来估计地球整体的平均化学成分。○1陨石类比法,即用各种陨石的平均成分或用球粒陨石成分来代表地球的平均化学成分。○2地球模型和陨石类比法来代表地球的平均化学成分,其中地壳占质量的1%,地幔31.4%,地核67.6%,然后用球粒陨石的镍—铁相的平均成分加5.3%的陨硫铁可以代表地核的成分,球粒陨石的硅酸盐相平均成分代表地壳和地幔的成分,用质量加权法计算地球的平均化学成分。(2)I型碳质球粒陨石其挥发性组成代表了太阳系中非挥发性元素的化学成分。 (二)陨石的类型和成分是用来确定地球内部具层圈结构的重要依据:由于陨石可以分为三种不同的陨石—石陨石、石铁陨石和铁陨石,因而科学家设想陨石是来自某种曾经分异成一个富含金属的核和一个硅酸盐外壳的行星体,这种行星经破裂后就成为各种陨石,其中铁陨石来自核部,石铁陨石来自金属核和硅酸盐幔的界面,而石陨石则来自富硅酸盐的幔区。这种设想成为推测地球内部结构和化学成分的重要依据之一。(三)碳质球粒陨石的有机化合物成分是研究地球早期生命系统的化学演化及来源的重要依据和信息,在碳质球粒陨石中已发现有机化合物60多种。有人认为地球早期生命系统的化学演化不一定来源于行星的大气,而有可能来自太阳星云凝聚时已合成的有机质。 2比较太阳系、地球、地壳主要化学元素丰度特征的异同点,说明自然界元素丰度的基本特征和决定自然体系中元素丰度的最基本因素:(1)特征的异同:太阳系:H>He>O>N>C>Si>Mg>S 地球;Fe>O>Mg>Si>Ni>S>Ca>Al>Ca>Na地壳:O>Si>Al>Fe>Ca>Na>K>Mg>Ti>H硅酸盐在地球表层富集,较难熔的镁铁硅酸盐和金属铁下沉。(2)自然界元素丰度的基本特征:○1个元素丰度随原子序数的增大而呈指数下降;在Z>45之后丰度值又相近。○2原子序数为偶数的同位素丰度大于奇数者(中子数、质量数同)——奥多-哈根斯法则;○3四倍原则:如O(A=16),质子数为4的倍数○4Li、P、B丰度很低,为亏损元素(核子结合能低,形成后易分解)○5Fe 和O过量(核子结合能最高,核子稳定)○6原子序数(质子数或中子数)是“幻数”的元素丰度高(氦、氧、钙等:2、8、14、20、2850、82、126)(3)决定自然体系中元素丰度的最基本因素:○1与原子结构有关具有最稳定原子核的元素分布最广,当中子数和质子数比例适当时核最稳定。如在原子序数<20的轻核中,中子∕质子等于一是,核最稳定,由此可以说明O、Mg、Si、Ca的丰度较大的原因;随原子序数增大,核内质子间的斥力大于核力,核子的结合能降低,原子核就趋于不稳定,所以元素同位素的丰度就要降低;偶数元素或同位

微量元素地球化学部分笔记

微量元素地球化学Trace Element Geochemistry 第0章绪论 1.微量元素地球化学定义:地球化学的重要分支学科之一,是研究微量元素在地球( 包括部分天体)形成、演化中分布、赋存状态、行为方式、分析技术和各类应用的分支学科。 地壳主要由O 、Si 、Al 、Fe 、Ca 、Mg 、Na 、K 、Ti 等九种元素组成,这九种元素占地壳总重量的99%左右—【主要元素&常量元素】。其它元素被统称为次要元素、微量元素、痕量元素、杂质元素或稀有元素等。 常量元素:能形成独立矿物,其分配受相律控制,遵循相律和化学计量法则。 ?微量元素:自然体系中浓度极低,不能形成独立矿物,可以成为副矿物其分配不受相律和化学计量法则限制。 ?major elements :地壳中平均浓度>1% ○minor elements :地壳中平均浓度∈[0.1%,1%] ○trace elements :地壳中平均浓度<0.1%,通常为ppm 或ppb 数量级 ○2.微量元素的定义:地球化学体系中,克拉克值低于0.1%的元素。 注:ppm=partspermillion=10-6;同理,ppb=10-9;ppt=10-12。 第一章微量元素的分类 亲石元素(Lithophile elements ) ?一.戈式分类 亲铁元素(Siderophile elements ) ?在岩石硅酸盐相中富集的化学元素。在地球中它们明显富集在地壳内,在自然界中都以氧化物,含氧盐,特别是硅酸盐的形式出现,如硅、铝、钾、钠、钙、镁、铷、锶、铀、稀土元素等。亲铜元素(Chalcophile elements ) ?富集于陨石金属相和铁陨石中的化学元素。它们与氧和硫的结合能力均弱,并易溶于熔融铁中;在地球中相对于地壳和地幔,明显在地核内聚集。典型的亲铁元素有镍、钴、金、铂族元素。亲气元素(Atmophile elements ) ?在硫化物相和陨硫铁(FeS)中富集的化学元素。在自然界中,它们往往易与S 2-结合成硫化物和复杂硫化物,如硫、铜、锌、铅、镉、砷、银、硒、碲、锑等。 组成地球大气圈的主要元素,惰性气体元素,以及主要呈易挥发化合物存在的元素,如氢、氮、碳、氧等。 注:①变价元素可以属于不同类别(i.e. 二价时属于亲铜元素;更高价时属与亲石元素) ②物理化学条件不同,具有不同的性质,可以属于不同类别条目 分类亲石(亲氧)元素亲铜(亲硫)元素亲铁元素亲气元素 离子最外层 结构 8电子(s 2p 6)稀有气体结构18电子(s 2p 6d 10结构8-18电子的过渡结构8电子电负性和电 离能 较低的电负性和电离能中等电负性和电离能较高电负性和第一电离能键性 离子键共价键金属键分子键(惰性元素为原子键)其他性质氧化物的生成热大氧化物的生成热小 于FeO 的生成热氧化物的生成热小形成具有挥发性或易形成挥发性化合物 Note.TE-Geochem

地球化学随堂作业

地球化学作业题 绪论 作业题 1、什么是地球化学? 2、试写出地球化学学科的主要奠基人及其对地球化学所作出的主要贡献。。 3、试写出国内外主要的地球化学类期刊的名称(各大于3种期刊)。 4、试写出5个主要地球化学分支学科的名称。 思考题 1、地球化学学科的基本特点和基本问题是什么? 2、地球化学与化学和地球科学其它学科在研究思路和研究方法上有何异同? 3、何谓地球化学思维? 第一章太阳系和地球系统化学元素的分布与分配作业题 1、何谓自然体中元素的丰度?何谓元素在自然体中的分布量? 2、何谓元素的克拉克值? 3、回答概念:元素的浓度克拉克值,元素的浓集系数。 4、试述载体矿物和富集矿物的概念,并举例说明其研究的意义。 讨论题 1、地壳中化学元素分布的规律及其产生的原因是什么? 2、试述元素无处不有定律。 3、为什么说碳质球粒陨石的组成可以代表太阳系非挥发性元素的丰度? 4、以元素的丰度特征来阐述质量作用定律在地球化学研究中的意义。 5、试阐明太阳系元素含量分布的奥多-哈金斯法则产生的原因。 思考题

1、太阳系、地球和地壳元素丰度特征的对比 2、陨石研究对于地球形成、组成特征及其演化的意义 3、元素克拉克值研究的地球化学意义。 4、地球和地壳元素丰度研究的难点是什么? 5、研究大陆地壳元素丰度方法的对比。 第二章元素的结合规律与赋存状态 作业题 1、回答概念:类质同像、类质同像混入物、固溶体。晶体场分裂能、晶体场稳定能和八面体择位能。 2、为什么硅酸盐矿物中K的配位数经常比Na的配位数大? 3、Zn2+和Mg2+的离子半径相近,但在天然矿物中,前者经常呈四面体配位,后者则常呈八面体配位,为什么? 4、指出下列微量元素经常会类质同象替代硅酸盐矿物结构中的哪种主要元素:(1)Rb,(2)Sr,(3)Ga,(4)Ti,(5)Li,(6)Ba,(7)Ge,(8)REE,(9)Pb,(10)Ni,(11)Mn. 5、下列矿物键的类型是什么?(1)所有键都是离子键;(2)所有键都是共价 键;(3)部分键为离子键,部分为共价键:(a)磷灰石;(b)黄铜矿;(c)萤石;(d)自然砷;(e)尖晶石。 讨论题 1、为什么碱性长石(钠长石、正长石、微斜长石)之间可以形成共生结构(条纹长石或反条纹长石),而在斜长石中却不能? 2、为什么结构与硅酸盐类似的碳酸盐没有形成种类复杂的碳酸盐矿物? 3、研究表明,高温高压下形成的岩浆岩中矿物种类数目最少,岩浆期后产物中矿物数目要大的多,而外生条件下生成的矿物数目最大。为什么?试从类质同象角度给予解释。 4、试论类质同象和固溶体形成的热力学原因。 5、试举出自然界不混溶地质现象的实例。

微量元素地球化学的发展

地球化学论文 题目:___微量元素地球化学的发展 年级:__________2010级________________ 专业:_________地质学__________________ 学号:_________03210301________________ 姓名:__________郭鹏__________________ 中国地质大学长城学院思想政治理论教研室 年月日 微量元素地球化学的发展

【摘要】近年来,微量元素地球化学得到了迅猛发展和广泛应用。作为地球化学领域里的一个重要分支学科,微量元素地球化学研究微量元素在地球及其子系统中的分布、化学作用及化学演化,它根据系统的特征和微量元素的特性,阐明他们在地球系统中的分布、分配、在自然体系中的性状、在自然界的迁移和演化的历史。 【关键字】微量元素地球化学化学作用化学演化 微量元素地球化学经历了两个主要的发展时期:在20世纪60年代前,主要通过元素的原子、离子半径,电荷、极化性质、电负性等特性.研究微量元素在地球各系统及不同矿物、岩石中的分配和分布,即从微观的角度来认识微量元素的分布及其在自然界的结合规律;自20世纪70年代起,微量元素地球化学的研究从定性向定量,从微观向宏观方向发展,进入了建立定量理论模型阶段。微量元素可作为地质地球化学过程的示踪剂,在解决当代地球科学的基础理论问题——如天体、地球、生命和元素的起源,为人类提供充足资源和良好生存环境等方面正发挥着重要的作用。至今,微量元素地球化学的研究几乎涉及地学的所有领域,包括对地幔的不均一性、古构造环境的恢复、成岩成矿物源的示踪、全球及局域环境的监测等问题的研究。微量元素地球化学研究的思路及方法可以归纳为: ①通过观察自然界中之“微”(微量元素)来认识地球之“著”(系统特征和其中的自然作用过程); ②在获得高精度数据的基础上,应用各种先进理论(如分配定律、耗散结构理论、协同论等)来认识地学的宏观规律。 近20年来,微量元素地球化学理论迅速发展、开辟了地球科学研究向定量、动态过程方向发展的新途径。微量元素在地球系统中不是孤立存在的,它们与各种地球物质和地质过程相联系。它们在各种地球化学体系的分散和集中与自身独特的赋存形式和共生组合有关。微量元素参与各种地球化学作用.作用过程中体系物理化学状态的转变、作用物质的质量迁移、能量输运及动量传递等,必然在微量元素组成上打上作用随时间演化的烙印。为此,通过观察、捕捉微量元素提供的地球化学作用的时-空信息,可用来解析各种复杂的地质作用的原因和条件、追踪作用演化历史,使为地球科学基础理论的发展、为人类提供充足资源和良好生存环境等做贡献成为可能。 微量元素地球化学的核心是“示踪”,因此本进展主要说明微量元素地球化学示踪作用的研究进展。 1壳幔作用微量元素地球化学示踪 板块构造学说的兴起,使恢复地壳小各种岩石或矿床形成时构造环境的研究越来越引起注意。按照现代地球科学的理论,大规模的构造活动主要起源于岩石圈深部,软流圈热动力状态的变化和运动的不均一性导致了地球物质的大规模运动。这种运动推动着岩石圈的演化。一般根据地球物理资料来研究地壳结构,并根据岩石组合类型恢复占构造环境(俯冲带、岛弧、洋中脊、弧后、板块内部等),但近年来的研究表明,由于不同构造环境的物质、热源、物理化学条件及动力学机制等方面存在差异.形成岩石的微量元素含量与组合(包括同位素组成)有较明显的不同。例如,洋中脊玄武岩的热源为上隆的软流层,物源为单纯洋壳的地幔,并处于拉张的动力学状态,又无陆壳的污染(仅与海水互相作用),决定了它们特定的微量元素组成特征,即富集Ti、Mn、P、Co、Ni、Cr、

地球化学知识点总结(详细)

第一章 克拉克值:元素在地壳中的丰度,称为克拉克值。元素在宇宙体或地球 化学系统中的平均含量称之为丰度。丰度通常用重量百分数(%), PPM(百万分之一)或g/t表示。 2 .富集矿物:指所研究元素在其中 的含量大大超过它在岩石总体平均含量的那种矿物。 3. 载体矿物:指岩石中所研究元素的主要量分布于其中的那种矿物。 4. 浓集系数 =工业利用的最低品位/克拉克值。为某元素在矿床中可工 业利用的最低品位与其克拉克值之比。 5.球粒陨石:是石陨石的一种。(约占陨石的84%):含有球体,具有 球粒构造,球粒一般为橄榄石和斜方辉石。基质由镍铁、陨硫铁、斜长 石、橄榄石、辉石组成。划分为: E群——顽火辉石球粒陨石,比较稀 少;O群——普通球粒陨石: H亚群—高铁群,橄榄石古铜辉石球粒损 石;L亚群—低铁群,橄榄紫苏辉石球粒陨石; LL亚群—低铁低金属亚群;C群——碳质球粒陨石,含有碳的有机化合 物和含水硅酸盐,如烷烃、芳烃、烯烃、氨基酸、卤化物、硫代化合物 等。为研究生命起源提供重要信息。分Ⅰ型、Ⅱ型和Ⅲ型。 Ⅰ型其非 挥发性组成代表了太阳系星云的非挥发性元素丰度。 6.浓度克拉克值=某元素在地质体中的平均含量/克拉克值,反映地质体 中某元素的浓集程度。 1.陨石在地化研究中的意义: (一)陨石的成分是研究和推测太阳系及地球系统元素成分的重要依 据:(1)用来估计地球整体的平均化学成分。1陨石类比法,即用各种 陨石的平均成分或用球粒陨石成分来代表地球的平均化学成分。2地球 模型和陨石类比法来代表地球的平均化学成分,其中地壳占质量的1%, 地幔31.4%,地核67.6%,然后用球粒陨石的镍—铁相的平均成分加5.3% 的陨硫铁可以代表地核的成分,球粒陨石的硅酸盐相平均成分代表地壳

相关文档
最新文档