JKS’S TSS
-1-
CONTENTS Contents (2)
High Reliability Experiment Lis t…………………………………………3-4
SMA(DO-214AC)Series…………………………………………………5-9
SMB(DO-214AA)Series…………………………………………………10-14
TO-92Series…………………………………………………15-19 DO-41/15/27Series…………………………………………………20-25
-2-
High reliability Experiment List可靠性试验项目
NO.
Experiment
Item
Time
or Cycle
Experiment
Conditions
Reference
1High
Temperature
Reverse Bias
96-180H
①T A=125±5℃forO/J
②T A=150±5℃for GPP
Bias=80%VR for all
MIL-STD-750D
METHOD-1038
2Steady-state
Operation Life
168-1000H
Rated average rectifier
current
IO=IF(AV)@TA=25℃
MIL-STD-750D
METHOD-1027
3HT Storage168-1000H TA=150±5℃MIL-STD-750D METHOD-1031
4Intermittent
Operation Life
1000CYCLE ON=5Min with rated IO
MIL-STD-750D
METHOD-1036
5Temperature
Cycling(air to
air)
10CYCLE
TH=150+3/-0℃10Min
TL=-55+0/-3℃10Min
Transfer time=5min
MIL-STD-750D
METHOD-1051
6Thermal Shock10CYCLE 0℃/5MIN
100℃/5MIN
MIL-STD-750D
METHOD-1056
7Soldering Heat10SEC260±5℃MIL-STD-750D METHOD-1031
High reliability Experiment List可靠性试验项目
-3-
NO.
Experiment
Item
Time
or Cycle
Experiment
Conditions
Reference
8Lead pull10SEC 1Kg in axial lead
direction
MIL-STD-750D
METHOD-1036
9Lead Fatigue3TIMES 0.5Kg weight applied to
each lead bending are90
±5℃
MIL-STD-750D
METHOD-1036
10Unbiased
Autoclave Test
4/8/16/24H
T A=121±2℃
P=29.7Psia/205KPa
RH=100%
11ForwordSurge
Current
1PULSE
8.3mS or10mS single
half sinewave
superimposed on rated
load
MIL-STD-750D
METHOD-1066
12Solderability10SEC245±5℃ANSI/J-STD-B10 2-E
JKS’S TSS SMA Series
-4-
Features
◆Bi-directional crowbar transient voltage protection
◆High surge capability
◆High off-state impedance
◆Low leakage current
◆Low on-state voltage
◆Short-circuit failure mode DO-214AC(SMA)
Main Application
ELA’s thyristor surge protector devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lighning,power contact,and power induction.These devices enable equipment to comply with various regulatory requirements including GR1089,ITU K.20,K.21and K.45,IEC 60950,UL60950,and TIA-968-A(formerly known as FCC Part68).
Typical application including:
●Central office switching equipment.Analog and digital linecards(xDSL,T1/E1,ISDN……)
●Customer Premises Equipment(CPE)such as phones,fax machines,modems,POS
terminals,PBX systems and caller ID adjunct boxes.
●Primary protection modules including Main Distribution Frames(MDF),building
entrance equipment and station protection modules.
●Access network equipment such as remote terminals,line
repeaters,multiplexers,cross-connects,WAN equipment,Network Interface Devices(NID).
●Data lines and security systems.
●CATV line amplifiers and power inserters.
●Sprinkler systems.
Electrcal Characteristics(Tamb=25℃)
-5-