Product Features
• • • • • • • • • • Technical parameters Operating Temperature:260℃-850℃ The maximum temperature :930℃ Protective tube operating temperature 350℃~850℃ Hexagonal screws operating temperature :≦570℃ Shell operating temperature ≦250℃ Plug operating temperature ≦120℃ Heater rated voltage:12V~14V Sensor output voltage:0~1000mV Response time: ≦200ms
IX.
Use cable bandings to tie the too long connection cable into a circle shape.
• •
ECU light the malfunction light
ቤተ መጻሕፍቲ ባይዱ
growing in pollution and decline in power and economics
Structural Features
• The main sensitive material of the oxygen sensor is a zirconia. • The zirconia is activated by exhaust heating (300℃) ,then the oxygen ions through the zirconia components to reach their external electrodes. Zirconia components induct the oxygen content in the engine exhaust and change the output voltage.
extended use

remove oxygen sensor

observed and judge
• • •
light gray damaged normal
white silicon pollution
brown black coke lead pollution
• • •
solve replace re-check replace replace coke failure
Zirconia Oxygen Sensor Manual Outline
• Type:zirconia sensor. • OEM NO. :39210 22610 • Certificate:TS16949 / ISO 9001
Working Principle
• The oxygen sensor is an important part of the closedloop fuel control system. It aims to adjust and maintain the desired air-fuel ratio so that it helps catalytic converters to achieve the best conversion efficiency. When the engine combustion air-fuel ratio becomes small, the oxygen content in the exhaust increasing, oxygen sensor output voltage reduced.Otherwise the output voltage increased.By this way to feedback the airfuel ratio situation to the ECU.
V.
Installation And Removal
VI. Do not twist wiring harness when you are screwingin/installing sensor. Do not pull the cable and plug. If the plug is dirty or damaged, the sensor shall not be used.
VII.
VIII. To ensure the oxygen sensor function well, please keep the plug inside clean. It is important to prevent plugs from contamination
Installation And Removal

oxygen sensor failure
• • • • • • • • •
lead contamination
silicon contamination
coke
broken
vent fouling
other
dirty oil coke failure use Leaded gasoline external mechanical forces low-quality oil coolant contains silicon pad
Structural Features
• The oxygen sensor using Teflon insulated wire, stainless steel molding components, the air enter from the wire. • Terminals: the A-low signal;B- high signal; C and Dconnected heating power • Installation: The oxygen sensor is installed between the exhaust valve and catalytic converter
II.
III.
Installation And Removal
IV. Re-install the sensor: use the right assembly adhesives coated thread. (Note: Do not let assembly adhesives touch the protective tube). Install a new sensor: we have coated the grease on the mounting thread and equipped with a protective sleeve. Do not remove the protective sleeve until you install the sensor.
Maintenance And Repair
• For engine oil, not oil more than the highest mark level on the dipstick. • Strict compliance with the testing and replacement cycle: should periodically (every 30,000 km) detect the oxygen sensor and the proposed cycle in accordance with our replacement.
Installation And Removal
I. In the operation of the oxygen sensor, it is recommended troubleshooting instructions related to the auto model. Assembly tools: use 22mm opening fixed wrench or adjustable wrench. Tightening torque: 40 ~ 60Nm (torque wrench).
Maintenance And Repair
Do follow to protect the oxygen sensor • Only use unleaded fuel without additives. • Regular maintenance and detection to the automobile • When Engine can not start, you can only use jumper cables to start. Not promote car to start, or the nonburning fuel will come into the exhaust system..
Failure Judgment
Note: All of the following judgment, based on the vehicle, harness, and other system components function properly. • Find system diagnostics fault by diagnostic equipment • Too little times of transitions between Concentrated dilute, heavy metals (such as: lead and manganese, etc.), phosphorus and sulfur poisoning, or high temperature damage.