东菱DLB1系列变频调速器使用说明书用户手册

合集下载

2018-东菱烤箱说明书-范文word版 (12页)

2018-东菱烤箱说明书-范文word版 (12页)

本文部分内容来自网络整理,本司不为其真实性负责,如有异议或侵权请及时联系,本司将立即删除!== 本文为word格式,下载后可方便编辑和修改! ==东菱烤箱说明书篇一:ICE0808东菱冰淇淋机说明书冰淇淋机ICE-0808 使用说明书目录一、重要的安全指引······················································二、产品部件名称························································三、产品规格····························································四、产品功能····························································五、首次使用前··························································六、冰淇淋桶的冷冻······················································七、操作步骤说明·························································八、安全注意事项························································九、故障分析····························································十、清洁与保养··························································十一、制作方法··························································十二、推荐步骤(蛋黄的加入方法)··········································十三、环保······························································十四、食谱推荐··························································一、重要的安全指引在使用冰淇淋机时,请遵循基本的安全措施以减少火灾、触电或损伤等事故给你带来的伤害,其中包括:1、使用之前阅读产品说明书;2、请勿将电源线、插头或电器盒放置在水或其它液体中以免触电;3、本产品不适合由8岁或以下的儿童以及肢体不健全、感觉或精神上有障碍或缺乏相关经验和知识的人使用,除非有人指导他们如何安全使用本产品、监督他们掌握安全使用方法,同时他们已经意识到相关的危险;4、在不使用时,装配或拆开部件及清洗前,请将电源插头拔开;5、请勿与转动部件接触。

调速器设置步骤及相关知识

调速器设置步骤及相关知识

调速器设置步骤及相关知识IMB standardization office【IMB 5AB- IMBK 08- IMB 2C】590调速器基本设置步骤1.上电(220V)后,按M键进入FULL MENUS,再按M键后用上下箭头键找到CONFIGURE DRIVE(基本参数设置全部在这里完成),按M 键进入.2.首先把CONFIGURE ENABLE内的参数DISABLE改为ENABLE,此时面板上的灯全部闪烁.按E键退出后用上下箭头键找到 NOM MOTOR VOLTS(电枢电压),ARMATUR CURRENT(电枢电流),FIELD CURRENT(励磁电流),根据电机铭牌上的数值写入590, 接着再把 MODE(励磁控制方法)设为CURRENT CONTROL(电流控制),把 RATIO(励磁电压比例)设为(电机铭牌上的励磁电压/380),然后把SPEED FBK SELECT(速度反馈选择)设为实际你所用的速度反馈(电枢电压反馈,测速发电机反馈或编码器反馈).3.以上参数输入590后,如果需要自整定(自整定后590能让电机更好的运行,但590报警的几率增大,根据现场情况,可以自整定,也可以不自整定),在CONFIGURE DRIVE用上下箭头键找到AUTOTUNE,把它的设定值由原来的OFF改为ON,然后运行590(让C3和C9接通),此时590上的RUN灯闪烁,等到液晶显示AUTOTUNE OFF,表示自整定结束,断开C3和C9.4.所有的参数设置好以后, 把CONFIGURE ENABLE内的参数ENABLE改回到DISABLE.然后在FULL MENUS里用上下箭头键找到PARAMETER SAVE,按M键进入显示UP TO ACTION 时,按上箭头键开始存储,等到存储结束后按E键退回到初始界面.5.上面的步骤完成后,就可以启动电机了.第一次运行时,一定要检测一下电机各方面的参数是否正常.调速器概述如何工作用简单术语讲,调速器就是使用控制环(一个内部的电流环和一个外部的速度环)来控制直流电机。

东标DB11系列标量变频器说明书

东标DB11系列标量变频器说明书

前 言感谢您选用DB系列变频器!北京東標电子传动产品DB系列高性能变频调速器自推出以来得到了广大用户的使用和认同。

它由高性能处理器控制,功能齐全,操作简便。

本手册叙述了DB变频器的技术规范、配线、故障查找和维护检查等。

在使用前,必须熟知本产品的安全注意事项,正确掌握使用方法并妥善保管本手册。

北京東標电子有限公司安全注意事项在产品安装、配线、运行、维护前必须认真阅读此用户手册。

手册中的注意事项分为“危险”、“警告”,必须严格按照注意事项操作,避免发生事故。

★ 危险:如果未按要求操作,可能造成变频器损坏或人员死亡或重伤。

★ 注意:如果未按要求操作,可能造成变频器损坏或人员伤亡。

产品保修条款一、产品保修期为铭牌记载的出厂日期起十二个月内。

在以下情况下,即使在保修期内也是有偿服务。

(1)使用时误操作或未经允许自行修理、改造引起的故障。

(2)超出变频器铭牌规定的规范使用而出现的故障。

(3)购买后跌损及运输中的损伤。

(4)由于地震、火灾、风灾、水灾、雷击、异常电压或其他自然灾害和灾害相伴原因引起的损伤。

二、在保修期内时:(5)出货后一个月内包换、包修、包退;(6)出货后十二个月内包修。

三、使用本公司产品超过保修期,本公司终生提供有偿服务。

第一章 概述注意:已经损坏或带有故障的变频器请勿安装和使用。

请客户收到变频器后,确认是否与订单相符。

1.1 验收检查检 查 项 目 说 明变频器型号是否和订单上一致 检查铭牌上的型号有无部件损坏 检查外观并核实运输期间有无损坏是否收到说明书 DB说明书 以上所列项目如有不符,请直接与本公司联系。

1.2 变频器的铭牌MODEL :DB11-75kW/380VINPUT :AC 3PH 380V 50HZOUTPUT :AC 3PH 75KW 146A 0~400HZS/N :★ 图1 变频器铭牌型号说明DB 1 1 — 75kW / 380V12★ 图2 型号、规格说明1.3 DB 系列变频器型号及技术规范(380V)形号DB22 55 75 110 315 最大适用电机功率(KW) 22 55 75 110 315 变频器容量 40 98 130 170 445 额定输出电流A 52128165 224590最大输出电压 三相380V额定输出额定输出频率 由参数设定,最高可达400Hz额定输入电压、频率 三相380 V、50 HZ允许电压波动范围 +10%,-15% 电源允许频率波动范围±15% 控制方式 SPWM 方式 频率控制范围 0.1~400Hz数字式指令±0.01%(-10℃~+40℃) 频率精度(温度波动) 模拟量指令±0.1%(25℃±10℃)数字式指令0.1Hz 频率设定分辨率 模拟量指令0.1Hz输出频率分辨率 0.1Hz过负载能力 B 系列120%额定输出电流1分钟 频率设定信号 0~+10V(20KΩ),4~20mA(250Ω) 加减速时间 0.0~3600秒(独立设定加速减速时间) 制动转矩 约20%(有制动单元,制动电阻约100%)控制特性V/F 模式种类 15个预置V/F 电机保护 电子热过载继电器保护瞬时过流变频器额定电流200%时电机滑行停止 过负载 B 系列120%额定输出电流1分钟后电机滑行停止过电压 整流器输出电压820V 以上时停止 欠电压 整流器输出电压380V 以下时停止 瞬时停电补偿 约2秒内的停电恢复时,继续运行散热片过热 由热敏电阻保护保护功能失速保护 加速/减速和恒速运转期间的失速保护温度 -10℃~+40℃(封闭壁挂型) -10℃~+45℃(敞开机架型)湿度90%RH 以下 保存温度 -20℃~+60℃使用场所 室内(无腐蚀性气体,液体的地方)海拔高度 1000米或以下,大于1000米时降额使用,请咨询公司 环境振动小于20Hz时为9.8M/S 2(1G),20~50Hz时最大为2M/S 2(0.2G)第二章 安装2.1安装现场DB系列变频器的安装现场应满足以下条件:1.避免阳光直射;2.无导电粉尘;3.无腐蚀及易燃易爆气体、液体、粉尘;4.安装基础坚固无振动;5.温度在-10℃~+40℃;6.无电磁干扰;7.无放射性物质;8.海拔不超过一千米;大于一千米降额使用。

变频器操作说明讲解

变频器操作说明讲解
DRIVE: 驱动模式时点亮 QUICK: QUICK程序模式时点亮 ADV: ADVANCED程序模式时点亮 VERIFY: 校验模式时点亮 A·TONE: 自学习模式时点亮
数字操作器的操作部分
键名功能LOCA源自/RRMO 根据参数o2-01的设定可以设
TE
定该键的有效/无效。
(运行操作选择) 有效时,按此键切换用数字
操作器运行还是用控制回路
端子控制运行。
MENU (菜单)
按此键在五种模式之间进行 切换。
ESC (退回)
按此键,返回到前一个状态。
JOG (点动)
在操作器运行场合的点动运行 键。
FWD/REV 在操作器运行场合,切换旋转 (正转/反转) 方向。
SHIFT/RESET 参数设置时的数位选择键。
模式的切换
按MENU键选择操作模式,例如进入 到QUICK程序模式时,对应的LED指 示灯开始闪烁,继续按MENU键则进 入下一个ADV程序模式,如此循环。 如果确定要进入某一种模式,则在该 模式的指示灯闪烁时按一次↙键,则 指示灯保持点亮状态而不再闪烁。此 时可以进一步修改具体的参数。
参数设定操作实例:
要将参数c1-02(减速时间)从10秒变更 到5秒的设定顺序。 1:接通电源,数字操作器显示“F
0.0”。 2:按下MENU键,选择驱动模式,
此时DRIVE的指示灯闪烁。 3:按下MENU键,选择QUICK程
序模式,此时QUICK的指示灯闪 烁。
4:按下MENU键,选择ADVANCED 程序模式。此时ADV的指示灯闪烁, 数字操作器显示“A1-00”。
STOP (停止键)
用操作器运行时,按此键变 频器停止运行。
用控制回路端子运行的场合, 根据参数o2-02的设定可以设 定该参数有效/无效。

富凌DZB500变频调速器使用手册

富凌DZB500变频调速器使用手册

C2 S字特 性
加减 速 时间的S字特 性设 定
○ ○ ○ ○ 5-12
C3 滑差补偿
滑差 补 偿功能 的设 定
○ ○ ○ ○ 5-12
C4 力矩补偿 C 调整
C5 速度控制
力矩 补 偿功能 的设 定 速度 控 制回路 的参 数设定
○ ○ ○ × 5-13 × ○ × ○ 5-15
C6 载波频率
载波 频 率的设 定
F 00.00
4
DSPL
LOCAL
PRGM
REMOTE DRIVE
JOG
D ATA SAVE
FWD REV
RESET
运行方式表示 DRIVE: 选择驱动方式时亮,选择程序模式
时灭。 FWD: 输入正转指令时亮 REV: 输入反转指令时亮 SEQ: 选择REMOTE模式时,端子输入
运行指令有效时亮 REF: 选择REMOTE模式时,端子输入
频率指令有效时亮 数据表示部分 显示速度、输出电流等的监视值及各种功能 的设定值。
操作器键盘
操作器键盘用 于变频 器的参数设置、 运 行、显 示参数 的选择 等 详 细 说 明 见表4.3
图4.1 数字 操 作器 的各部 名称和 功能
4.1.2 数字操作器(LED)数据显示说明 表4.2 LED显示代码对照表
3: 运转指 令来 自选择卡
b1-02 运转指令选择
· 停 止运行时 ,由LOCAL/REMOTE键, 可选择 × Q Q Q Q 运行模式。
LOCAL:频率指 令和运 转指令 来自键盘。
0-3 REMOTE: 频 率指令和 运转 指 令 由参 数b1-01和 b1 - 02决 定。
注: 当电源输 入时REMOTE被设 定。

东菱伺服调试步骤及注意事项

东菱伺服调试步骤及注意事项

• • • • •
• •
命令脉冲的形式
• 脉冲+方向,CW/CCW, AB正交
l



mm/P



A
ห้องสมุดไป่ตู้
B




×
4


P
G
(P/rev)




m
电子齿轮比的设定
n


(mm/rev)
=P
电子齿轮比的设定
• 电子齿轮比的计算公式 l(mm/P):脉冲当量 PG(P/rev):编码器线数 P(mm/rev):滚珠丝杠节距 m n :减速比 • A:PA-31参数 B:PA-32参数 • A和B请通过用户参数设定
手动增益调整
• 伺服单元的用户参数中主要包括以下伺服 增益。通过设定这些增益,可以调整伺服 单元的响应特性。 • PA-11:位置环增益(Kp) • PA-14:速度环增益(Kv) • PA-15:速度环积分时间常数(Ti)
手动增益调整
制动电阻的连接
• 如果连接电阻值过小的制动电阻器,那么 ,流过制动电路的电流就会增大,有可能 造成电路击穿。 • 与制动电阻相关的还有一个参数占空比的 参数PA-151。
伺服调试时的注意事项
• • • • • • • 为了保证伺服驱动器能够可靠、稳定、正确的运行,在伺服系统的安装、调 试以及使用过程中,应注意以下事项: 1)正确的接线:东菱伺服标配编码器线和电机动力线,不过接线时一定要正 确连接伺服驱动器与控制器之间的信号线,否则伺服不会正常运行; 2)正确的设置伺服控制模式:由于每种机器应用都有所不同,所以正确的设 置伺服控制模式是保证伺服正确运行的前提; 3)根据实际运行效果正确匹配增益参数,另外东菱伺服不要在伺服使能的情 况下或电机运行的情况下设置电子位置环和齿轮比参数。 4)确保电机良好的接地,驱动器与设备机壳连接。一方面避免干扰,另一方 面避免漏电。 5)信号线尽量选择屏蔽双绞线,屏蔽层一般接到端子外壳; 6)注意干扰问题,避免编码器信号和控制信号受到干扰,编码器线、信号线 不要与电机线、电源线绑扎在一起或者通过一个线槽, 尽量保持一定距离。

东菱电梯使用维护说明书07-07-23

东菱电梯使用维护说明书07-07-23
7.X43、X47二次保护的点
内选登记有效,电梯无法关门启动电梯不能关门
1.该层外呼按钮按下后未能弹起复位
用工具轻轻挑起复位即可
2.门系统发生故障或由于异物卡住厅门或轿门
清除异物或排除相应
3.开门按钮按下后未能弹起复位
4.光幕或力限开关动作
5.超载动作
6.关门到位开关未动作
7.开门到位开关未动作或门未开到位
8.消防开关动作(电梯在消防基站)
9.内选登记无效时,安全是下限位开关故障
检查下限位开关,必要时可更换
2.如只能下行,可能是上限位开关故障
检查上限位开关,必要时可更换
找出故障点,调整厅门或更换相应开关
3.关门到位开关未动作,但厅、轿门联锁正常
4.电梯运行状态显示板(控制柜正面)显示状态为安全、厅轿门显示灯均亮(此时应特别注意安全)
开门停梯,请电梯维修人员进行维修
5.电源问题,380V、+110V、+24V是否正常
查明原因,恢复正常
6.有关数据寄存器设备出错
重新设置
一般故障的诊断及排除
故障现象
分析
处理
内选登记有效,厅门关闭后电梯没有运行
1.电梯运行状态显示板(控制柜正面)显示状态仅厅门灯亮,可能是轿门未关闭完全或轿门联锁开关损坏
调整轿门或更换开关
2.电梯运行状态显示板(控制柜正面)显示状态仅轿门灯亮,可能是本层或其它楼层的某扇或某儿扇厅门未关好或厅门锁开关损坏

东菱DLA1系列变频调速器使用说明书用户手册

东菱DLA1系列变频调速器使用说明书用户手册

1.1 铭牌说明 (1)1.2 产品系列说明 (2)1.3 技术规范 (3)2 安装配线 (5)2.1 变频器各部件名称 (5)2.2 外围设备的连接图 (6)2.3 产品外型图和安装孔位尺寸 (7)2.3.1 产品外型图 (7)2.4 标准接线图 (8)2.5 主回路配线 (10)2.5.1 DLA1系列 (10)2.6 控制回路配线 (11)2.6.1 控制板端子定义 (11)2.6.2 控制信号说明 (11)2.6.3控制回路接线说明 (12)2.6.4 控制回路跳线说明 (14)3 键盘操作说明 (15)3.1键盘界面介绍 (15)3.1.1操作面板功能说明 (15)3.2 参数设定举例 (16)3.2.1功能码查看、修改方法说明 (16)3.2.2状态参数的查看方法 (17)3.2.3密码设置 (17)3.2.4电机参数自动调谐 (17)3.3试运行 (18)4功能码详细说明 (19)4.1基本监视参数: d0.00-d0.65 (19)4.2基本功能组: P0.00-P0.28 (22)4.3第一电机参数: P1.00-P1.37 (26)4.4 V/F控制参数: P2.00-P2.15 (27)4.5 矢量控制参数: P3.00-P3.22 (28)4.6 输入端子: P4.00-P4.39 (30)4.7 输出端子: P5.00-P5.22 (38)4.8 启停控制: P6.00-P6.15 (41)4.9 键盘与显示: P7.00-P7.14 (42)4.10 辅助功能: P8.00-P8.53 (43)4.12 故障与保护: P9.00-P9.70 (46)4.11 PID功能: PA.00-PA.28 (51)4.12摆频、定长和计数: PB.00-PB.09 (53)4.13 多段指令、简易PLC: PC.00-PC.51 (53)4.14 通讯参数: PD.00-PD.06 (55)4.15 功能码管理: PP.00-PP.04 (56)4.16转矩控制参数: B0.00-B0.08 (57)4.17控制优化参数: B5.00-B5.09 (58)5异常诊断与处理 (59)5.1 故障报警及对策 (59)5.2 常见故障及其处理方法 (67)6 MODBUS通讯协议 (68)6.1 通讯协议 (68)6.1.1协议内容 (68)6.1.2协议说明 (68)6.2 校验方式 (70)6.3 通信参数的地址定义 (72)附录Ⅰ:制动配件 (76)图1-1铭牌说明电源相数:T :三相 S :单相变频器系列DLA1-02D2 T 4 G适配电机功率(KW)G: 通用型,P: 风机水泵型电压等级:2:220V 4:380V 5:480V变频器专用代码【1】【2】【3】【6】【5】【4】图1-2产品型号说明图1-1变频器部件名称控制端子电机线按键板电源线断路器或漏电开关电机接地输出用交流电抗器(AC)变频器输入侧干扰滤波器(MC)输入用交流电抗器(AC)电源制动电阻器图2-1外围设备的连接图2.3.1 产品外型图键盘尺寸图键盘托尺寸图图2-3 0.4~2.2KW外型尺寸及安装尺寸示意图380V系列制动电阻三相380V电源图2-12 380V系列变频器接线示意图220V系列单相220V电源图2-12 220V系列变频器接线示意图2.5.1 DLA1系列380V系列主回路端子说明如下:图2-14主回路端子符号图(0.4~5.5KW)220V系列单相2.6.1 控制板端子定义2.6.2 控制信号说明2.6.3 控制回路接线说明1.模拟输入端子因微弱的模拟电压信号特别容易受到外部干扰,所以一般需要用屏蔽电缆,而且配线距离尽量短,不要超过20m,如图2-12,在某些模拟信号受到严重干扰的场合,模拟信号源侧需要加滤波电容器或铁氧体磁芯,如图2-13。

AE2000B1型系统说明书11

AE2000B1型系统说明书11

A E2000B1型过程控制实验系统使用手册系统说明书目录第一章硬件系统 (3)1.1系统主要特点 (4)1.2实验对象组成结构 (5)1.2.1 检测装置 (6)1.2.2 执行装置 (8)1.3控制台组成结构 (9)1.3.1 电源和I/O信号面板 (9)1.3.2 智能调节仪面板 (10)1.3.3 远程数据采集模块ICP-7017、ICP-7024面板 (13)1.3.4 S7200PLC模块面板 (15)1.3.5 流量积算变送仪面板 (21)1.3.6 变频器面板 (22)1.4RS-485接口转换器与通讯电缆 (24)1.4.1 RS-485接口转换器 (24)1.4.2 通讯电缆 (24)第二章软件系统 (25)2.1S7200PLC下位机程序软件 (25)2.1.1 STEP 7-Micro/WIN32软件简介 (25)2.1.2 S7200PLC程序的下载 (27)2.1.3 程序中开放的变量 (29)2.2MCGS组态软件 (31)2.2.1主控窗口 (31)2.2.2 设备窗口 (31)2.2.3 用户窗口 (32)2.2.4 实时数据库 (32)2.2.5 运行策略 (33)第一章硬件系统生产与生活的自动化是人类长久以来所梦寐以求的目标,在18世纪自动控制系统在蒸汽机运行中得到成功的应用以后,自动化技术时代开始了。

随着工业技术的更新,特别是半导体技术、微电子技术、计算机技术和网络技术的发展,自动化仪表已经进入了计算机控制装置时代。

在石油、化工、制药、热工、材料和轻工等行业领域中,以温度、流量、物位、压力和成分为主要被控变量的控制系统都称为“过程控制”系统。

过程控制不仅在传统工业改造中,起到了提高质量,节约原材料和能源,减少环境污染等十分重要的作用,而且已成为新建的规模大、结构复杂的工业生产过程中不可缺少的组成部分。

随着计算机控制装置在控制仪表基础上的发展,自动化控制手段也越来越丰富。

东菱面包机说明书

东菱面包机说明书

大家在设置时间前一定要记得先装上电池,面包机一般采用两节7号电池,位置在面包机底部.装好后显示屏上会显示当前时钟为上午(am)12:00,时钟显示方式为12小时制,以am和pm区别上午或下午。

在待机状态下按暂停键一次,12开始闪烁,再按时间键设置小时;小时设置完成后,再按一次暂停键,00开始闪烁,按时间设置分钟。

最后时间设置完成再按一次暂停键或者等5秒后确认当前时间即可.一般不用延时功能我们可以按以下操作, 第一,设置好当前时钟.(记住必须要将面包机的当前时刻设置好,否则时间会出现偏差) 第二,按一次时间键,每按一次时间健增加10分钟,继续按时间键,直至设置到你希望面包完成的时间。

然后按(开始/停止)健,设置完成。

第三,设置好后,显示屏中间的第二行时间为面包做好的时间。

接下来我们来说说今天的重点,大家一般早上都要早起上班,时间较紧,不可能大清早起床来做早餐面包,况且,快速面包程序做出的面包口感也较其它程序稍逊,这里,延时功能就给大家带来了方便,延时功能要如何设置了,大家跟我一起慢慢来设置第一,按上面普通时间设置好后再按一次时间键,显示屏出的时间为:当前时钟+所选程序的总工作时间+10分钟,继续按时间键,设置完成时间。

为了大家能够清晰的明白如何设置,在这里给大家举例说明, 例如当前时钟为上午8:00,所选程序的工作时间为3小时,你想在下午2点时将面包做好。

1、按时间键,时间显示为上午11:10,继续按时间键将预约时间设置为下午2:00。

2、按开始/停止键启动程序。

3、显示屏上显示预约时间下午(pm)2:00,时间数字不再变化,同时setreadytime(设置延时时间)一直显示出来。

4、按时间键可查看当前时间。

5、当延时程序运行到所选程序的工作时间时,面包机什么牌子好,机器开始工作,且菜单时间数字开始倒计时。

若大家想取消延时设置,需长按开始/停止键3秒,听到一声蜂鸣声,即代表取消设置的程序。

另外,这里在给大家一个时间设置后的参考信息.如果我们早晨7:00设定面包在下午4:00做好,那么显示时间为pm4:00sameday(当天)。

YTB-S2系列交流电机变频调速器使用说明书概述

YTB-S2系列交流电机变频调速器使用说明书概述

YTB-S2系列交流电机变频调速器使用说明书概述YTB-S2系列变频器是我公司在YTB-S1的基础上改进而来,它保持了原有的优点,改善了运行性能, 增加了直流制动功能,及其它附属功能. 使调速更可靠,应用更广泛.,采用先进的SMD工艺,严格的出厂质检,能够满足用户的多种使用要求.开箱检查1 确认在运输过程中是否造成损坏。

2 检查变频器的铭牌以确定在您手中的产品就是所订货品。

3 检查包装箱内含变频器本体一台,使用说明书一份,出厂合格证一张及其它选购品。

安装与结构1.安装为了提高散热效果,应垂直安装变频器,安装底板应为铁质或为其它阻燃耐热材料,并留有足够的通风空间(周围至少留有12CM以上的空间).2.接线打开接线盖板,即可看到主接线柱和控制用接线柱。

端子说明见表二。

位置排列如图3, 图4为典型接线图.说明 U ,V ,W 变频器输出端子 连接三相电动机 P ,PR制动电阻端子 连接制动电阻控制回路 接线端子 说明X1,X2,X3,X4 多功能外接端子详见参数一览表中的说明 COM 与X1,X2,X3,X4相连的公共端 0V, 相对于+5V, +12V I+ 0-10mA 输入“+”端参见典型接线图VR外接电位器输入端(电位器中点) 电位器其它两端接+5V, COM. +12V 直流电压输出(正端) 可供给外接传感器用(最大20mA) r1,r2,r3多能继电器输出触点r3 为继电器中间转换触点K在位置1K在位置2K在位置3+5V COM I++12V VR X1X2X3X4r1r2W U 图3V PR P R 频率设定方式开关,K*频率设定方式开关K 的设置(模拟信号)外接电位器方式面板上的电位器1 2 3电流输入方式公共端COMX30--10mA输入I+r3空(T)S计数脉冲输入或定时器暂停端子+多功能端子公共端外接电位器单相或三相输入S10KX2VR +5V COMX1(T)MCRX4r1多机能继电器复位端图4外接刹车电阻变频器机壳V MP PRWr2r3U 安 全 事 项1. 此变频器仅应用于工业三相感应电机。

珠峰DLT系列变频器说明书

珠峰DLT系列变频器说明书

一产品简介1、拆箱时的检查本机在出厂前均作严格的包装处理,但考虑运输过程中的各种因素,装配前请特别注意以下事项,如有异常,请通知本产品经销商或本公司相关人员。

◇搬运中是否损坏或变形。

◇包装拆开时是否有 ACI 系列变频器一台及使用说明书一本。

◇所订购规格是否与铭牌相符合(使用电压等级及 KVA 数)。

◇内部装配的零件,配线及电路板是否异常。

◇各端子是否紧锁,机器内是否有异物存在。

◇附加配件的有无。

◇合格证及保修卡的有无。

2、铭牌说明:ACI±MODEL:DLT-G110022S4±±022G S4040610583、变频器型号说明:DLT 变频器系列G110015S4代号2电压等级220V380V660V代号G11 P11 Z11名称通用型风机水泵型注塑型46ZK 注塑一体化型代号TS 输入电压单相三相代号适配电机功率0007 0015 0022 0037 0055 0075 0110 0150 0185 0220 0300 0370 0450 0550 0750 0930 1100 1320 1600 2000 2200 2600 2800 3150 40000.75KW1.5KW2.2KW3.7KW 5.5KW 7.5KW 11KW 15KW 18.5KW 22KW 30KW 37KW 45KW 55KW 75KW 93KW 110KW 132KW 160KW 200KW 220KW 260KW 280KW 315KW 400KW二安装与配线本章将提供给使用者安装本机及配线正确的方法,为求系统安全及确保本机能够正常的运转,在安装之前,必须详细阅读本使用手册。

实施配线时,务必按照本章所提供的配线方法进行。

1、安装方法垂直安装并列安装出风接线孔进风●注意事项:◇变频器必须竖直安装。

◇环境温度为-10℃~+40℃。

◇环境相对湿度不大于 90%,且无水珠凝结现象。

◇不受阳光直射、无水滴、蒸汽、灰尘及油性灰尘的场所。

DORNA东菱伺服基础技术手册上

DORNA东菱伺服基础技术手册上

DORNA东菱伺服基础技术手册上交流全数字伺服驱动器EPS系列基础技术手册l非常感谢您选购EPS系列交流伺服驱动器l在您使用驱动器之前,请仔细阅读本技术手册,按照手册上的规范操作安全注意事项1安全注意事项(使用前请仔细阅读)在产品的安装、运行、维护和检查前请仔细阅读本技术手册,在熟悉了有关设备的知识、安全信息和全部注意事项后再使用本产品。

请将此技术手册妥善保存,以备随时查阅。

如果您不能解决产品出现的问题,请及时联系我们。

n 由于产品的改进,手册内容可能变更,恕不另行通知。

n 在未得我公司授权下,用户对产品的改动我公司将不承担任何责任,产品的保修将因此作废。

注意下列警告,以免伤害人员、防止器件损坏。

n 下面的“危险”和“警告”符号是按照其事故危险的程度标出的危险指示一个潜在的危险情况,如果使用不当,会产生危险状况,有导致人员重伤甚至死亡的可能。

警告指示一个潜在的危险情况,如果使用不当,可能会产生危险状况,有导致人员受到中等程度伤害或轻伤的可能,或者发生物件损坏。

n 下列符号表示哪些是禁止的操作,哪些是必须遵守的。

安全注意事项2警告目录目录第一章功能和构成 (3)1.1EPS系列驱动器技术规格 (3) 1.2EPS系列驱动器功能 (4)1.3EPS系列驱动器命名规则 (5)1.4EPS系列驱动器外形尺寸 (6)1.5EPS系列驱动器适配电机 (14)1.6各部分名称 (17)第二章安装 (19)2.1环境条件 (19)2.2驱动器安装场合 (19)2.3安装方向和间隔 (20)2.4电机的安装 (21)2.5伺服驱动器安装示意图 (21)2.6电缆应力 (22)第三章接线 (23)3.1伺服驱动器与外围设备的连接及构成 (23) 3.2标准接线 (24)3.4编码器信号端子CN3 (32)3.5I/O接口原理 (34)3.6电源系统电路 (38)第四章参数 (39)4.1参数功能 (39)第五章监控与操作 (49)5.1面板操作 (49)5.2监视方式(DISP) (50)5.3参数设置(SET-P) (53)1目录5.4参数管理(EEPOP) (53)5.5速度试运行 (55)第六章报警与处理 (57)6.1驱动器报警 (57)6.2报警处理 (58)第七章伺服电机 (63)7.1型号命名 (63)7.2电机安装尺寸 (77)附录 (84)2第二章安装3第一章功能和构成1.1 EPS 系列驱动器技术规格表1.1 驱动器技术规格控制回路电源单相AC220V-15~+10% 50/60Hz主回路电源三/单相AC220V -15~+10% 50/60Hz环境温度工作:0~55 ℃存贮:-20℃~80℃ 湿度小于90%(无结露)振动小于0.5G(4.9m/S 2),10~60Hz (非连续运行)控制方式IGBT PWM 正弦波控制控制模式①位置控制②速度控制③转矩控制④位置/速度控制⑤位置/转矩控制⑥速度/转矩控制⑦内部位置控制⑧内部速度控制⑨内部转矩控制⑩试运行控制控制输入①伺服使能②报警清除③位置偏差清零④指令脉冲禁止CCW ⑤驱动禁止CW ⑥驱动禁止⑦控制方式选择⑧零速箝位控制输出①伺服准备好②伺服报警③机械制动释放④位置/速度到达⑤零速检出⑥转矩限制中Z ⑦相输出编码器反馈 2500p/r ,15线增量型,差分输出500 p/r ,15线增量型,差分输出通讯方式RS232 RS485 ①②显示与操作①5位LED 显示4②个按键制动方式通过内置/外接制动电阻能耗制动冷却方式风冷(热传导膜具、高速强冷风扇)适配电机可通过参数设置适配不同型号电机功率范围≤22KW第二章安装41.2 EPS 系列驱动器功能表1.2 驱动器功能一览表控制功能位置控制外部输入脉冲形式脉冲/方向,CW/CCW ,A/B 两相最大指令脉冲频率500Kpps (差分输入)电子齿轮1/1800~1800(推荐:1/50~50)脉冲输入指令禁止信号位有效时,指令脉冲输入被禁止;可通过参数屏蔽此信号内部位置指令 8种位置设定速度控制外部速度指令0~±10V DC零速钳位通过此功能使得速度保持为0 速度控制范围1~3000内部速度指令3种速度设定转矩控制外部转矩指令 0~±10V DC 内部转矩指令3种转矩设定转矩控制范围外部转矩指令:0~300% 内部转矩指令:0~300%驱动禁止当CCWL/CWL 信号有效时,电机在CCW/CW 方向输出零速保持力矩监视功能转速、当前位置、指令脉冲积累、位置偏差、电机转矩、电机电流、转子位置、指令脉冲频率、运行状态、输入输出端子信号等保护功能过压、欠压、过流、过速、过载、Z 脉冲丢失、编码器出错、EEPROM 错误、位置超差等报警功能工作异常时输出报警号,同时5个LED 小数点位闪烁信号显示在显示部分显示外部输入、输出信号的ON/OFF 状态增益调整在电机运行或停止时改变增益以调节驱动器性能报警记录可记忆包括当前报警在内的4个报警记录第二章安装产品代号:T 表示通用型、H 表示横机专用型、W 表示袜机专用型、K表示数控专用型 E 表示经济型、G 表示高性能型硬件版本:版本A、版本B…额定功率:1. 功率的位数增加到4位,单位为KW。

变频器基本参数的调试

变频器基本参数的调试

变频器基本参数的调试一加减速时间加速时间就是输出频率从0上升到最大频率所需时间,减速时间是指从最大频率下降到0所需时间.通常用频率设定信号上升、下降来确定加减速时间。

在电动机加速时须限制频率设定的上升率以防止过电流,减速时则限制下降率以防止过电压。

加速时间设定要求:将加速电流限制在变频器过电流容量以下,不使过流失速而引起变频器跳闸;减速时间设定要点是:防止平滑电路电压过大,不使再生过压失速而使变频器跳闸。

加减速时间可根据负载计算出来,但在调试中常采取按负载和经验先设定较长加减速时间,通过起、停电动机观察有无过电流、过电压报警;然后将加减速设定时间逐渐缩短,以运转中不发生报警为原则,重复操作几次,便可确定出最佳加减速时间。

二转矩提升又叫转矩补偿,是为补偿因电动机定子绕组电阻所引起的低速时转矩降低,而把低频率范围f/V增大的方法.设定为自动时,可使加速时的电压自动提升以补偿起动转矩,使电动机加速顺利进行。

如采用手动补偿时,根据负载特性,尤其是负载的起动特性,通过试验可选出较佳曲线。

对于变转矩负载,如选择不当会出现低速时的输出电压过高,而浪费电能的现象,甚至还会出现电动机带负载起动时电流大,而转速上不去的现象。

设定的原则是,以最低工作频率时能带动负载为前提,尽量减小补偿程度。

三电子热过载保护本功能为保护电动机过热而设置,它是变频器内CPU根据运转电流值和频率计算出电动机的温升,从而进行过热保护.本功能只适用于“一拖一”场合,而在“一拖多”时,则应在各台电动机上加装热继电器.电子热保护设定值(%)=[电动机额定电流(A)/变频器额定输出电流(A)]×100%。

电子热继电器的保护整定值一般为电动机额定电流的(0、95-—1、05)倍。

四频率限制即变频器输出频率的上、下限幅值。

频率限制是为防止误操作或外接频率设定信号源出故障,而引起输出频率的过高或过低,以防损坏设备的一种保护功能。

在应用中按实际情况设定即可。

DORNA东菱伺服基础技术手册(中)

DORNA东菱伺服基础技术手册(中)

第三章 接线第三章 接 线【注 意】l 进行接线或检修作业时,必须先断开电源,因伺服驱动器内部有大容量电 解电容,所以即使切断了电源,内部部分电路仍有高压。

在电源切断后, 最少等待 10 分钟以上,等到充电指示灯熄灭后,才能接线或检修驱动器和 电机,否则可能触电l 驱动器输出端子 U、V、W 和电机 U、V、W 必须正确对应。

注意不能用调 换三相端子的方法来使电机反转,这一点与异步电机完全不同,更不要使 端子短路。

若相序出错,就会出现电机不能启动、运转异常等不可意料的 情况l 电机轴上的编码器与驱动器之间的接线绝对不能接错。

为避免感应干扰, 编码器信号线应和动力线分开走线,最好给信号线加上屏蔽3.1 伺服驱动器与外围设备的连接及构成图 3-1 伺服驱动器 EPS-TA0003123-0000 与外围设备的连接图 23第三章 接线3.2 标准接线 1. 配线(1)电源端子 TB 线径:R、S、T、U、V、W、PE 端子线径≥1.5mm² (AWG14-16),L1、L2 端子线径≥1.0mm² (AWG16-18)。

驱动器功率越大需要 TB 端子线径越粗。

接地:接地线(PE)应尽可能粗,驱动器接地线与伺服电机接地线一点接 地,接地电阻<100Ω。

端子连接必须连接牢固。

建议电源采用三相隔离变压器供电,提高电源质量和抗干扰能力。

请安装非熔断性(NFB)断路器,以便驱动器出现故障时能及时切断电源。

建议安装噪声滤波器(NF)、磁力接触器(MC)、电抗器(L),防止外部杂 波进入电源,减轻伺服电机产生的杂波对外界的干扰。

(2)通讯信号 CN1、控制信号 CN2、编码器信号 CN3 线 径 : 建 议 采用 屏 蔽 电 缆( 最 好 采用 双 绞 屏蔽 电 缆),线 径 ≥0.12mm² (AWG24-26)。

线长:电缆长度尽可能短,控制信号线 CN2 电缆不超过 5 米,编码器信号 电缆长度不超过 15 米,编码器电源和地线应分别采用 4 组以上芯线并联。

Optidrive ODE-3 调速变频器用户手册说明书

Optidrive ODE-3 调速变频器用户手册说明书

用户手册1快速指南IP20 & IP66 (NEMA 4X)交流调速变频器0.37 – 22kW (0.5 – 30HP)110 – 480V11.快速指南 (4)1.1. 重要的安全信息41.2. 快速启动步骤51.3. 快速启动概要62.基本信息和额定值 (7)2.1. 通过型号了解变频器72.2. 变频器型号73.机械安装 (8)3.1. 概述83.2. 符合UL 要求的安装83.3. 机械尺寸和安装– IP20开放式安装83.4. 箱体内安装指导– IP20 83.5. 机械尺寸– IP66 (Nema 4X) 封装93.6. 安装指导 (IP66 变频器) 93.7. 密封盖和电源隔离锁定103.8. 取下端子盖103.9. 日常维护104.电源和控制端子接线 (11)4.1. 接线图114.2. 接地保护 (PE) 114.3. 输入电源连接124.4. 电机连接124.5. 电机端子盒连接124.6. 控制端子接线134.7. 使用 REV/0/FWD 选择开关 (仅对于带开关的变频器) 134.8. 控制端子连接134.9. 电机热过载保护144.10. 符合EMC 标准要求的安装144.11. 可选制动电阻145.运行 (15)5.1. 面板操作155.2. 操作显示155.3. 改变参数155.4. 访问只读参数155.5. 参数恢复155.6. 故障复位156. 参数 (16)6.1. 标准参数166.2. 扩展参数176.3. 高级参数206.4. P-00 只读状态参数217. 模拟和数字输入宏配置 (22)7.1. 概述227.2. 宏功能键227.3. 宏功能–端子模式 (P-12 = 0) 227.4. 宏功能–面板模式 (P-12 = 1 or 2) 237.5. 宏功能–现场总线控制模式 (P-12 = 3, 4, 7, 8 or 9) 237.6. 宏功能–用户 PI 控制模式 (P-12 = 5 or 6) 237.7. 火灾模式247.8. 接线图举列248.Modbus RTU 通讯 (25)8.1. 简介258.2.Modbus RTU 指标258.3. RJ45 连接器配置258.4. Modbus 寄存器定义259.技术数据 (26)9.1. 环境269.2. 额定数据表269.3. 三相变频器的单相运行269.4. 符合UL的其他信息279.5. EMC 滤波器断开2710.故障处理 (28)10.1. 故障代码信息28地区分销商可能提供不同的保修条款,在这些情况下,应该先联系地区分销商。

东菱DL-T06(BM1230)面包机使用说明书配料表_pdf_word

东菱DL-T06(BM1230)面包机使用说明书配料表_pdf_word
1/2大勺(4g)
2+1/2大勺(25g)
1/2小勺(3g)
4大勺(45g)
240g
1+2/3小勺(5g)
米饭80g
700g
160ml
3/4大勺(5g)
3大勺(30g)
2/3小勺(4g)
4+1/2大勺(55g)
300g
2小勺(6g)
米饭100g
5
米粉面包
450g
155ml
1/2大勺(4g)
3(大勺28g)
烘烤
鸡蛋3个(150g)、细砂糖6.25大勺(75g)、低筋面粉半杯(80g)、融化无盐黄油0.7大勺(10g)
15
翻炒干货
材料
时间
重量
材料
时间
重量
材料
时间
重量
生花生
45分钟
250g
生瓜子
75分钟
250g
开心果
90分钟
250g
16
肉松
猪肉(瘦肉)250g、盐5g、白糖10g、米酒(醋)12g、生抽5g、食用油15g
380g
1+2/3小勺(5g)
2
法式面包
450g
132ml
1大勺(6g)
1+1/3大勺(13g)
1/2小勺(3g)
2+1/4大勺(27g)
280g
1小勺(3g)
700g
200ml
1+1/2大勺(10g)
2大勺(20g)
5/6小勺(5g)
3+1/2大勺(40g)
420g
1+2/3小勺(5g)
3
粗粮面包
3大勺(36g)
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

1.2 产品系列说明 (2)1.3 技术规范 (5)2 安装配线 (8)2.1 变频器各部件名称 (8)2.2 外围设备的连接图 (9)2.3 产品外型图和安装孔位尺寸 (10)2.3.1 产品外型图 (10)2.3.2 外型及安装孔位尺寸 (18)2.3.3 外引键盘的外型尺寸 (20)2.4 标准接线图 (21)2.5 主回路配线 (23)2.5.1 DLB1系列 (23)2.6 控制回路配线 (25)2.6.1 控制板端子定义 (25)2.6.2 控制信号说明 (25)2.6.3控制回路接线说明 (26)2.6.4 控制回路跳线说明 (29)3 键盘操作说明 (31)3.1键盘界面介绍 (31)3.1.1操作面板功能说明 (31)3.2 参数设定举例 (32)3.2.1功能码查看、修改方法说明 (32)3.2.2状态参数的查看方法 (33)3.2.3密码设置 (33)3.2.4电机参数自动调谐 (33)3.3试运行 (34)4功能码详细说明 (35)4.1基本监视参数: d0.00-d0.41 (35)4.2基本功能组: P0.00-P0.28 (40)4.3第一电机参数: P1.00-P1.37 (48)4.4 矢量控制参数: P2.00-P2.22 (50)4.5 V/F控制参数: P3.00-P3.15 (51)4.6 输入端子: P4.00-P4.40 (59)4.7 输出端子: P5.00-P5.22 (69)4.8 启停控制: P6.00-P6.15 (73)4.9 键盘与显示: P7.00-P7.14 (77)4.10 辅助功能: P8.00-P8.54 (80)4.12 故障与保护: P9.00-P9.70 (88)4.11 PID功能: PA.00-PA.28 (97)4.12摆频、定长和计数: PB.00-PB.09 (102)4.13 多段指令、简易PLC: PC.00-PC.51 (103)4.14 通讯参数: PD.00-PD.06 (107)4.15 PE组 (109)4.16 功能码管理: PP.00-PP.04 (110)4.17转矩控制参数: B0.00-B0.08 (112)4.18控制优化参数: B5.00-B5.09 (114)5异常诊断与处理 (116)5.1 故障报警及对策 (116)5.2 常见故障及其处理方法 (124)6保养和维护 (125)6.1 定期检查 (125)6.2 零部件更换年限 (125)7 MODBUS通讯协议 (126)7.1 通讯协议 (126)7.1.1协议内容 (126)7.1.2协议说明 (126)7.2 校验方式 (128)7.3 通信参数的地址定义 (130)7.4 Pd组通讯参数说明: (134)附录Ⅰ:参数设定一览表 (136)附录Ⅱ:变频器扩展卡说明 (152)附录Ⅱ-1 多功能卡DLB1-PC1 ................................... 错误!未定义书签。

1 概述....................................................................................... 错误!未定义书签。

2 机械安装与控制端子功能说明......................................... 错误!未定义书签。

附录Ⅱ-2 通用编码器扩展卡 ....................................... 错误!未定义书签。

1概述.......................................................................................... 错误!未定义书签。

2 机械安装与控制端子功能说明........................................... 错误!未定义书签。

附录Ⅲ:制动配件.. (152)附录Ⅳ:外围电气元件选型指导 (162)DLB1变频器外围电气元件选型指导 (162)外围电气元件的使用说明 (166)附录Ⅴ:符合EMC要求的安装指导 (167)EMC一般常识 (167)变频器的EMC特点 (167)EMC安装指导 (168)图1-1铭牌说明电源相数:T :三相 S :单相变频器系列DLB1-0011 T 4 G适配电机功率(KW)G: 通用型,P: 风机水泵型电压等级:2:220V 4:380V 5:480V 变频器专用代码【1】【2】【3】【6】【5】【4】图1-2产品型号说明若需表中的选配件,请在订货时说明。

图2-1 DLB1变频器和部件名称电机输出用交流电抗器(AC)(MC)输入用交流电抗器(AC)图2-2 外围设备的连接图2.3.1 产品外型图图2-3 0.4~1.5KW外型尺寸及安装尺寸示意图图2-4 2.2~3.7KW外型尺寸及安装尺寸示意图图2-5 5.5~7.5KW外型尺寸及安装尺寸示意图图2-6 11~18.5KW外型尺寸及安装尺寸示意图图2-7 22~30KW外型尺寸及安装尺寸示意图图2-8 37~55KW外型尺寸及安装尺寸示意图图2-9 75~110KW外型尺寸及安装尺寸示意图图2-10 132~187KW外型尺寸及安装尺寸示意图图2-11 200~315KW外型尺寸及安装尺寸示意图2.3.2 外型及安装孔位尺寸输入电压380V变频器外型及安装孔位尺寸2.3.3 外引键盘底座的外型尺寸图2-12 0.4~1.5KW外引键盘底座的外型尺寸图2-13 2.2KW以上外引键盘底座的外型尺寸说明:外引键盘底座,是客户直接卡在电气柜上,用来安装外引键盘的,键盘使用网线外拉。

三相380V电源DLB1系列图2-14 0~18.5KW变频器接线示意图三相380V电源DLB1系列图2-15 22~400KW变频器接线示意图2.5.1 DLB1系列主回路端子说明如下:图2-16 主回路端子符号图(0.4~1.5KW)主回路端子说明如下:图2-17 主回路端子符号图(2.2KW~7.5KW)主回路端子说明如下:图2-18 主回路端子符号图(11~18.5KW)主回路端子符号说明如下:图2-19 主回路端子符号图(22~187KW)注意:1、外接直流电抗器时,需去掉P、P+之间的短接铜排。

2、如需能耗制动时,可在P+与P-之间接直流制动单元,带直流制动电阻。

2.6.1 控制板端子定义2.6.2 控制信号说明2.6.3 控制回路接线说明1.模拟输入端子因微弱的模拟电压信号特别容易受到外部干扰,所以一般需要用屏蔽电缆,而且配线距离尽量短,不要超过20m ,如图2-20,在某些模拟信号受到严重干扰的场合,模拟信号源侧需要加滤波电容器或铁氧体磁芯,如图2-21。

电位器图2-20 模拟量输入端子接线示意图图2-21 模拟量输入端子处理接线图2. 输入端子一般需要用屏蔽电缆,而且配线距离尽量短,不要超过20m。

当选用有源方式驱动时,需对电源的串扰采取必要的滤波措施。

建议选用触点控制方式。

数字输入分为NPN晶体管输入和PNP晶体管输入。

(a)NPN晶体管输入时,使用内部24V电源,+24V端子和SP端子短接,COM 端子为公共端,J9为23跳线。

此种接法也称之为漏极接线方式,最为常见。

图2-22 NPN晶体管输入接线图(COM为公共点)(b)PNP晶体管输入时,使用外部24V电源,外部电源负端接SP端子;外部电源正端为公共点,此时J9为12跳线。

外部电源电压范围:9~30V。

此种接法也称之为源极接线方式。

图2-23 PNP晶体管输入接线图(外部电源正端为公共点)3.输出端子数字量输出为集电极开路输出,如果使用外部电源,请将外部电源负端接入COM 端子。

集电极开路输出的最大电流为50mA,如果外部负载为继电器,请在继电器两端加装续流二极管。

注意:请正确安装续流二极管的极性,否则会损坏内部器件。

续流二极管图2-24 数字输出接线图2.6.4控制回路跳线说明图 2-25 0.4~1.5KW控制板跳线位置图控制回路跳线说明 1、 SP 跳线(J9)内部24V外部供电1231232、 AO1跳线(J1)电压0-10V电流0-20mA1231233、 AO2跳线(J2)电压0-10V电流0-20mA1231234、 AI1跳线(J3)电压0-10V电流0-20mA1231235、 AI2跳线(J4)电压0-10V电流0-20mA1231236、 AI3跳线(J5)电压0-10V电流0-20mA1231237、AI3跳线(J6)端子AI3键盘电位器123123图2-24 2.2KW~187KW 控制板跳线位置图控制回路跳线说明 1、SP 跳线(J9)内部24V外部供电1231232、 AO1跳线(J1)电压0-10V电流0-20mA1231233、 AO2跳线(J2)电压0-10V电流0-20mA1231234、AI1跳线(J3)电压0-10V电流0-20mA1231235、AI2跳线(J4)电压0-10V电流0-20mA1231236、AI3跳线(J5)电压0-10V电流0-20mA1231237、AI3跳线(J6)端子AI3键盘电位器123123用键盘,可对变频器进行功能参数修改、变频器工作状态监控和变频器运行控制(起动、停止)3.1.1 操作面板功能说明3.2.1 功能码查看、修改方法说明DLB变频器的操作面板采用三级菜单结构进行参数设置等操作。

三级菜单分别为:功能参数组(一级菜单)→功能码(二级菜单)→功能码设定值(三级菜单)。

操作流程如图3-2所示。

图3-2说明:在三级菜单操作时,可按MON/ESC键或DATA/ENTER键返回二级菜单。

两者的区别是:按DATA/ENTER键将设定参数保存后返回二级菜单,并自动转移到下一个功能码;而按MON/ESC键则直接返回二级菜单,不存储参数,并返回到当前功能码。

举例:将功能码P3.02从10.00Hz更改设定为15.00Hz的示例。

(粗体字表示闪烁位),如图3-3。

图3-3在第三级菜单状态下,若参数没有闪烁位,表示该功能码不能修改,可能原因有:1)该功能码为不可修改参数。

如实际检测参数、运行记录参数等;2)该功能码在运行状态下不可修改,需停机后才能进行修改。

3.2.2 状态参数的查看方法在停机或运行状态下,通过移位键“>>”可分别显示多种状态参数。

由功能码P7.03(LED 运行显示参数1)、P7.04(LED运行显示参数2)、P7.05(停机参数)按二进制的位选择该参数是否显示。

在停机状态下,四个运行状态参数:设定频率、母线电压、模拟输入AI1电压、模拟输入AI2电压为默认显示,其他的显示参数分别为:DI输入状态、DO输出状态、模拟输入AI3电压、实际计数值、实际长度值、PLC运行步数、负载速度显示、PID设定、PULSE输入脉冲频率及3个保留参数是否显示由功能码P7.05按位(转化为二进制)选择,按键顺序切换显示选中的参数。

相关文档
最新文档