混凝土水化热分析
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
!100*80*10基岩上浇筑混凝土50*40*10,每三天浇筑1米高(第一天浇完,剩下两天窝工),
!共用一个月时间,分为十层(layer)浇筑,模型、条件均为假设
!建模
/filename,test
/PREP7
BLOCK,,50,,10,,40,
BLOCK,-25,75,-10,0,-20,60
ET,1,70
LSEL,S,,,9,12,1
LESIZE,ALL,,,10
LSEL,S,,,21,24,1
LESIZE,ALL,,,20
LSEL,S,,,2,4,2
LSEL,A,,,5,7,2
LESIZE,ALL,,,10
LSEL,S,,,14,16,2
LSEL,A,,,17,19,2
LESIZE,ALL,,,20
LSEL,S,,,1,3,2
LSEL,A,,,6,8,2
LESIZE,ALL,,,10
LSEL,S,,,13,15,2
LSEL,A,,,18,20,2
LESIZE,ALL,,,5
allsel
MP,DENS,1,2400.0 !混凝土材料
MP,KXX ,1,300.89
MP,C,1,0.94500
MAT,1
VMESH,1
MP,DENS,2,2600.0 !基岩材料
MP,KXX ,2,300.89
MP,C,2,0.94500
MAT,2
VMESH,2
nummrg,all
!热分析
/SOLU
NROPT,FULL !Specifies the Newton-Raphson options in full transient analysis
ESEL,S,MAT,,2 !MAT2 IS 基岩
NSLE,S
IC,all,TEMP,16.4, !加基岩初温
ASEL,S,,,7,9,1
ASEL,A,,,11,12,1
NSLA,S,1
SF,all,HFLUX,0 !加基岩绝热边界条件
NSEL,S,LOC,Y,-0.1,0.1
ASEL,S,,,3
NSLA,U,1
SF,ALL,CONV,2016,20 !加基岩第三边界条件(和空气接触面)
!加初始条件
ALLSEL,ALL
ESEL,U,MAT,,2
NSLE,S
EKILL,ALL !KILL 混凝土
IC,all,TEMP,35, !混凝土浇筑时温度为35度
ANTYPE,TRANSIENT,new !分析类型
!日子的流逝
*DO,LAYER,1,10,1
!激活第N层单元
ALLSEL,ALL
NSEL,S,LOC,Y,(LAYER-1),LAYER !第一层从Y=0~1米,第二层从Y=1~2米,...
ESLN,S ,1
EALIVE,ALL
*DO,DAY,LAYER*3-2,LAYER*3,1 !每三天浇筑一层
ALLSEL,ALL
ASEL,S,,,1,2,1
ASEL,A,,,5,6,1
NSLA,S,1
NSEL,R,LOC,Y,0,LAYER
NSEL,A,LOC,Y,LAYER-0.1,LAYER+0.1
SF,ALL,CONV,2016,20 !加混凝土第三类对流边界条件
*DO,LOOP,1,LAYER,1
ALLSEL,ALL
NSEL,R,LOC,Y,LOOP-1,LOOP
ESLN,S,1
TDAY=DAY-(LOOP-1)*3 !已经完工的天数
HE00=47880*(TDAY/(0.862+TDAY)-(TDAY-1)/(0.862+TDAY-1))
BFE,ALL,HGEN, ,HE00 !加水化热
*ENDDO
!计算设置
ALLSE
TRNOPT,FULL
LUMPM,0
TIME,DAY
AUTOTS,0
DELTIM,1, , ,1
KBC,0
TSRES,ERASE
OUTRES,ALL,ALL,
SOLVE
*ENDDO
ESEL,S,MAT,,1
NSLE,S,
SFEDELE,ALL,ALL,CONV !删对流边界条件
SFDELE,ALL,CONV
*ENDDO
FINISH
!结构分析
/PREP7
ET,1,SOLID65 !变热单元为结构单元
*DIM,EXX,ARRAY,30 !考虑变化的EX
EXX(1)=0.325E10,0.57778E10,0.78E10,0.94545E10,0.10833E11,0.12E11,0.13E11,0.13867E11,0.14625E11,0.15294E11, 0.15889E11, 0.1642E11 ,0.169E11, 0.17333E11, 0.17727E11, 0.18087E11,0.18417E11,0.1872E11
EXX(19)=0.190E11, 0.19259E11, 0.195E11, 0.19724E11, 0.19933E11, 0.20129E11,0.20312E11, 0.20485E11, 0.20647E11, 0.208E11, 0.20944E11, 0.21081E11
*DO,I,1,30,1 !定义材料,混凝土浇筑完每过一天变一种材料
MP,DENS,I,2400
MP,EX,I,EXX(I)
MP,PRXY,I,0.167
MP,ALPX,I,0.9E-5
MP,R
EFT,I,15
*ENDDO
MP,DENS,31,2600 !定义基岩材料
MP,EX,31,0.20800E+11
MP,PRXY,31,0.167
MP,ALPX,31,0.9E-5
ESEL,S,MAT,,,2
MPCHG,31,ALL, !!变热材料为结构材料
ALLSEL
/SOLU
NROPT,FULL !Specifies the Newton-Raphson options in a full transient analysis
NLGEOM,ON
NSLA,S,,,7,9,1
NSLA,A,,,11,12,1
D,all,ALL !加基岩约束
!KILL THE CONCRETE ELEMENT
ESEL,U,MAT,,1
NSLE,S
EKILL,ALL !KILL 混凝土
*DO,DAY,1,30,1 !随时间改变,变换材料
*DO,LAYER,1,10
*IF,DAY,GT,LAYER*3-3,THEN
NSEL,S,LOC,Y,LAYER-1,LAYER
ESLN,S,1
EALIVE,ALL !ACTIVE NEXT LAYER
MPCHG,DAY-(LAYER-1)*3,ALL, !CHANG MAT
ALLSEL,ALL
*ENDIF
*ENDDO
ALLSEL,ALL
ACEL,0,0,-9.8, !GRAVITY LOAD
LDREAD,TEMP,,,DAY, ,’TEST’,’rth’,’ ’ !TEMP LOAD Reads results from the results file and applies them as loads.
CNVTOL,F, ,0.2,2,200, !Sets convergence values for nonlinear analyses.
TIME,DAY
AUTOTS,0
DELTIM,1, , ,1
KBC,0
TSRES,ERASE !Defines an array of keytimes at which the time-stepping strategy changes
OUTRES,ALL,ALL,
SOLVE
*ENDDO
!1、定义重力集散地是应为正值:ACEL,0,0,9.8
!2、砼单元边长(1*4*5)相差5倍,对计算精度的影响会不会较大?
!3、热单元SOLID70对应的结构单元为SOLID45,改为SOLID65是否合适?
!4、原分析得到的结果与实际情况比较如何?
!5、如何体现气温的变化?
我在陕西境内做过28m×6m×3m的钢管拱桥桥墩承台,没有加冷管,采取如下措施没有出现混凝土温度裂缝。
1、混凝土配合比采用掺加粉煤灰替代部分水泥,减少水化热。
2、混凝土配合比掺加缓凝高效减水剂,推迟水化热峰值出现时间。
3、采用高标号水泥,减少水泥用量,减少水化热。
4、采用保温蓄热办法养护,降低混凝土内外温差,减少混凝土温度梯度。
关于大体积砼的定义现在各种说法不一。
1、建筑业认识审核的几个问题中:
对大体积混凝土的鉴别有两个条件:1混凝土浇注量大于100平方米;2、长、宽、高任意一边不小于1米。
/iso-b6.htm
2、所谓大体积混凝土,一般理解为尺寸较大的混凝土,美国混凝土学会给出了大体积混凝土的定义:任何现浇混凝土,其尺寸达到必须解决水化热及随之引起的体积变形问题,以最大限度的减少开裂影响的,即称为大体积混凝土。
3、我还看过一个结构任何一边大于3m的即为大体积砼。
另外,大体积混凝土的温控首先要在混凝土配合比设计中应选择低热水泥,加入粉煤灰和外加剂,尽量降低水泥用量;其次,一定要在结构的底层和表面的设置足够强的抗裂钢筋网。这两项工作非常重要,如果做好的话,温控至少成功了70差即使超标了
混凝土也不一定会开裂。养护期间,冷却水的调节和承台表面保温保湿也要做好。
我要做的是说明模拟过程中的考虑因素,注意对象是给老师说,所以要力求清楚简洁。说明是我软件模拟能力还不到位所以忽略了哪些东西,保留了那些东习。这是这次中的重点。
大体积混凝土由于散热困难,容易发生早期热裂缝。控制温度是解决开裂的主要常用手段。目前采用的控温措施一是采用大掺量矿物掺合料如粉煤灰,利用其低水化热,或者采用冷却原材料的方法控制入模温度不超过30摄氏度。另一种有效的手段是设置冷却水管,冷却水管可以是钢管或塑料管,前者效果好,但是价格高,后者效果较差,但是便宜。冷却水管的设置间距应根据混凝土结构尺寸和传热效果决定。一般冷却管间距为400~1000mm,这取决结构类型和所用水泥。荷兰Westerschelde 隧道的侧壁施工埋设冷却管(直径30mm的钢管或塑料管),混凝土拌和后40~60 h开始通冷水。施工结束后,应通过灌浆填堵钢管。
研究表明,冷却水管管径对它能控制的混凝土冷却区域影响不大。