检测报告Test Report

报告编号: 20141215 第 1 页共6 页Report No.: 20141215 Page 1 of 6

客户名称: /

Client : /

客户地址:/

Address : /

样品信息:

Description of the submitted sample(s):

样品名称: USB2.0

Sample Name : USB2.0

样品型号: /

Model/Type : /

额定参数: DC2.0A

Ratings : DC 2.0A

测试项目: 温升测试

Test Item : Temperature rise test

环境温湿度: 25-28℃, 63%R.H.

Surrounding : 25-28℃, 63%R.H.

样品状态: 正常

State of Sample(s) : Normal

样品数量: 1 个

Sample Quantity : 1pc

制造商:

Manufacturer :

样品接收日期: 2014-12-15

Sample Received Date : Dec. 15, 2014

样品检测日期: 2014-12-15

Sample tested Date : Dec. 15, 2014

检测要求: 1)UL1977:2009条款16;

2)依据客户要求。

Test Requested。: 1) Clause 16 of UL1977: 2009;

2) According to client’s requirements.

检测报告Test Report

报告编号: 20141215 第 2 页共6 页Report No.: 20141215 Page 2 of 6 设备清单:

检测结果: 合格

Test Results:PASS

测试数据请参见下页。

Test data details refer to next page.

主检:审核:

Tested by: Reviewed by:

批准:日期:

Approved by: Date :

实验室主管

Lab Supervisor

检测报告Test Report

报告编号: 20141215 第 3 页共6 页

Report No.: 20141215 Page 3 of 6

1.测试方法:

Test procedure:

1)应选择接线端子上有可能导致最高温度的位置进行温度测量。测试应该持续4个小时即使温度在短时间

内达到稳定。达到稳定状态是指三个连续5分钟时间间隔,温度没有进一步上升。

Temperatures shall be measured on the wiring terminals of the pole location judged most likely to result in the highest temperatures. The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time. A temperature is considered to be stabilized when three consecutive readings, taken at 5 minute intervals, indicate no further rise above the ambient temperature.

2)所有触点应串联使得通过相同电流,电流为DC2.0A 。

All contacts are to be connected in series so as to carry the same test current, the input is DC2.0A .

3)测试应该在无空气对流环境温度范围为25 ±5°C (77 ±9°F)的条件下进行。测试在25°C以外的环境温度下

得到的结果,应通过增加测试的环境温度与25°C之间的偏差,调整到环境温度为25°C。

This test is to be made in a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F).

Tests conducted at an ambient temperature other than 25°C are to have the test results adjusted to an ambient temperature of 25°C by adding the appropriate variation between 25°C and the ambient.

4)样品每个触点的温升不能超过规定的30℃。

5)Each contact of the specimen must not exceed the specified temperature rise of 30 ℃.

2. 测试数据:

检测报告Test Report

报告编号: 20141215

第 4 页共6 页

Report No.: 20141215 Page 4 of 6

图1-测试位置

Fig.1- Test locations

图2-温升曲线

Fig.2- Temperature rise curve 测试点1 测试点2 测试点3 测试点4