USB2.0-2 温升测试报告
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
检测报告Test Report
报告编号: 20141215 第 1 页共6 页Report No.: 20141215 Page 1 of 6
客户名称: /
Client : /
客户地址:/
Address : /
样品信息:
Description of the submitted sample(s):
样品名称: USB2.0
Sample Name : USB2.0
样品型号: /
Model/Type : /
额定参数: DC2.0A
Ratings : DC 2.0A
测试项目: 温升测试
Test Item : Temperature rise test
环境温湿度: 25-28℃, 63%R.H.
Surrounding : 25-28℃, 63%R.H.
样品状态: 正常
State of Sample(s) : Normal
样品数量: 1 个
Sample Quantity : 1pc
制造商:
Manufacturer :
样品接收日期: 2014-12-15
Sample Received Date : Dec. 15, 2014
样品检测日期: 2014-12-15
Sample tested Date : Dec. 15, 2014
检测要求: 1)UL1977:2009条款16;
2)依据客户要求。
Test Requested。: 1) Clause 16 of UL1977: 2009;
2) According to client’s requirements.
检测报告Test Report
报告编号: 20141215 第 2 页共6 页Report No.: 20141215 Page 2 of 6 设备清单:
检测结果: 合格
Test Results:PASS
测试数据请参见下页。
Test data details refer to next page.
主检:审核:
Tested by: Reviewed by:
批准:日期:
Approved by: Date :
实验室主管
Lab Supervisor
检测报告Test Report
报告编号: 20141215 第 3 页共6 页
Report No.: 20141215 Page 3 of 6
1.测试方法:
Test procedure:
1)应选择接线端子上有可能导致最高温度的位置进行温度测量。测试应该持续4个小时即使温度在短时间
内达到稳定。达到稳定状态是指三个连续5分钟时间间隔,温度没有进一步上升。
Temperatures shall be measured on the wiring terminals of the pole location judged most likely to result in the highest temperatures. The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time. A temperature is considered to be stabilized when three consecutive readings, taken at 5 minute intervals, indicate no further rise above the ambient temperature.
2)所有触点应串联使得通过相同电流,电流为DC2.0A 。
All contacts are to be connected in series so as to carry the same test current, the input is DC2.0A .
3)测试应该在无空气对流环境温度范围为25 ±5°C (77 ±9°F)的条件下进行。测试在25°C以外的环境温度下
得到的结果,应通过增加测试的环境温度与25°C之间的偏差,调整到环境温度为25°C。
This test is to be made in a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F).
Tests conducted at an ambient temperature other than 25°C are to have the test results adjusted to an ambient temperature of 25°C by adding the appropriate variation between 25°C and the ambient.
4)样品每个触点的温升不能超过规定的30℃。
5)Each contact of the specimen must not exceed the specified temperature rise of 30 ℃.
2. 测试数据:
检测报告Test Report
报告编号: 20141215
第 4 页共6 页
Report No.: 20141215 Page 4 of 6
图1-测试位置
Fig.1- Test locations
图2-温升曲线
Fig.2- Temperature rise curve 测试点1 测试点2 测试点3 测试点4