保存温度和时间对外送标本检测影响的评估
血液标本放置时间和温度和血常规检测结果的相关性探讨
血液标本放置时间和温度和血常规检测结果的相关性探讨发布时间:2022-09-14T02:31:13.158Z 来源:《医师在线》2022年11期作者:黄梅[导读] 分析血液标本放置时间、保存温度对血常规检测结果的影响。
黄梅兴文县人民医院四川宜宾 644400【摘要】:目的:分析血液标本放置时间、保存温度对血常规检测结果的影响。
方法:选择100名健康体检者参与本次研究,均接受血常规检查,且积极配合采集清晨空腹静脉血10ml(4管)。
对比室温下不同放置时间、相同放置时间下不同保存温度的血常规检测结果。
结果:血液标本在室温下放置0.5h、3h、6h后,PLT、RBC、WBC、RDW-SD检测结果均存在较大差异(P<0.05),Hb无明显变化(P>0.05);血液标本在放置0.5h后,室温下和低温下的各项血常规项目中PLT、RBC、WBC、RDW-SD存在较大差异(P<0.05),Hb无明显变化(P>0.05)。
结论:血液标本放置时间和保存温度都会在很大程度上影响血常规检测结果,且对不同指标的影响程度有所不同。
【关键词】:血常规检测;血液标本;放置时间;保存温度【Abstract】Objective: To analyze the influence of blood specimen storage time and storage temperature on blood routine test results. Methods: 100 healthy people were selected to participate in this study, all of them received routine blood examination, and actively cooperated to collect 10ml (4 tubes) of fasting venous blood in the morning. The blood routine test results of different storage time at room temperature and different storage temperature under the same storage time were compared. Results: After blood samples were placed at room temperature for 0.5h, 3h, and 6h, the detection results of PLT, RBC, WBC, and RDW-SD were significantly different (P<0.05), and there was no significant change in Hb (P>0.05). After being placed for 0.5h, there were significant differences in PLT, RBC, WBC, and RDW-SD in various blood routine items at room temperature and low temperature (P<0.05), and there was no significant change in Hb (P>0.05). Conclusion: The storage time and storage temperature of blood samples will affect the results of blood routine test to a large extent, and the degree of influence on different indicators is different.【Key words】: blood routine test; blood specimen; storage time; storage temperature血、尿、便检查是临床三大常规检验方式,可为疾病的诊断鉴别以及疗效判定等提供科学客观的数据支持[1],以血常规为例,通过取末梢血或静脉血等血液,测得血液中相关物质水平,近些年科学技术持续发展,越来越多智能化的检测机器诞生且应用于检验科,大大减少检验结果误差[2],但检验结果影响因素仍未完全消除,如血液标本放置时间、保存温度等,本文从这两个角度分析,探讨对血常规检测结果的实际影响,详情见正文。
标本放置时间及温度对血氨检测结果的影响观察
标本放置时间及温度对血氨检测结果的影响观察摘要:目的:探究标本放置时间及温度对血氨检测结果的影响。
方法:以我院2017年3月-2018年3月期间收取的96份标本进行离心,后采用干化学法检测浓度。
将所有标本一式两份,分别置于在室温和3℃冷藏条件下。
观察对比室温状态下30min、60min、120min和180min状态下的血氨浓度。
结果:室温状态下放置30min,溶液浓度与0h浓度相比,无统计学差异(P<0.05)。
但放置30min以上,溶液浓度数值均呈现大幅度上升,与0h浓度相比存在统计学差异(P<0.05)。
冷藏状态下30min、60min、120min的血氨浓度与0h血氨浓度相比,无统计学差异(P<0.05)。
但是120min以上检测的血氨浓度数值与0h浓度相比,存在明显统计学差异(P<0.05)。
结论:血氨标本采集后,应在30min内完成检测。
如不能及时检测,可放置于3℃冰箱内冷藏,于120min内完成检测。
关键词:标本放置时间;温度;血氨检测前言血氨可用于检测患者肝性脑病,还可辅助诊断和判定治疗效果[1]。
患者在空腹状态下采血检测血氨数值,有助于帮助患者检测肝性疾病。
但是标本放置时长和温度都会对检测结果产生影响,造成漏诊和误诊现象。
故本文选取96例健康体检患者,对其开展了不同温度、不同放置时间的血氨浓度检测,现报道如下。
1资料与方法1.1一般资料纳入96例健康体检患者,选自我院2017年3月-2018年3月间。
采集患者血液5ml,分为两份。
于标本采集后8min后,送至实验室开展检验。
纳入标准:(1)纳入年龄在20-45岁之间的健康人群;患者与其家属知晓研究,并签署了知情同意书。
(2)排除标准:患有恶性肿瘤的患者。
1.2方法仪器选用美国强生Vitros350全自动干化学仪,试剂采用原装试剂及配套质控品。
在配置试剂和试管过程中,应该避免含氨用品的使用。
采血管采用肝素锂抗凝负压采血管,开展试验。
血清标本放置时间和温度对部分生化项目结果的影响
血清标本放置时间和温度对部分生化项目结果的影响目的:探讨血清标本放置时间和温度对部分生化项目结果的影响。
方法:将60例混合血清即刻测定13项生化指标(ALT,AST,TB,ALB,TG,CHO,BUN,CR,GLU,UA,CK,LDH)然后分别将每例分成20份,分别加盖密封放置在-20 ℃、4 ℃、25 ℃、37℃条件下,并于1 h、2 h、4 h、8 h和24 h后重测,并与放置前测定的值进行比较。
结果:除在37 ℃放置24 h后CK测定结果超出了实验室允许范围外,其余测定结果均在实验室允许范围内。
结论:血清标本放置在-20~37 ℃24 h内较稳定。
标签:血清标本;放置时间;温度;生化项目常规生化检验随着生化仪器的更新,室内、室间质控普遍开展,分析中质量控制日益得到重视,对分析前质量控制有所忽视,而在临床检验过程中有许多情况下标本采集后得不到及时检测,如仪器故障、试剂短缺、停水停电等等,为了了解分析前某些因素对生化指标的影响程度,笔者对常用的13项生化指标在不同温度和不同时间条件下的测定结果进行了比较,现将结果报告如下。
1 资料与方法1.1 一般资料随机选取本院健康体检者,按常规要求采血后分离血清,适当混血后制成10 ml一例的标本。
1.2 研究方法将上述标本每例分成21份,每份0.5 ml,放入Eppendorf管。
1份即刻测定,其余20份分别放置在-20 ℃、4 ℃、25 ℃、37 ℃4种温度下,并于1 h、2 h、4 h、8 h和24 h后重测。
1.3 仪器与质控品仪器为HITACHI7180全自动生化分析仪,RANDOX质控品。
1.4 统计学处理每个时间点的数据以形式表示。
变异百分数与实验室允许误差范围进行比较(+表示升高,-表示降低)。
2 结果不同温度下的不同时间测定结果分别见表1~4。
3 讨论临床检验中发生的差错,有很多是由于分析前标本的采集与处理不当引起的,血标本在离开人体以后,仍在不断发生各种反应,因此,存储后的标本,其质量受很多因素的影响[1]。
全血标本保存时间和温度对血常规检测结果的影响分析
全血标本保存时间和温度对血常规检测结果的影响分析目的:分析探讨全血标本保存时间和温度对血常规检测结果的影响。
方法:随机抽取2016年1-12月120例体检者作为研究对象,每位体检者采集3份静脉血,分别置于32 ℃水溶箱、25 ℃温箱与4 ℃冰箱中保存,分别于不同时刻进行检测,以即时检测值作为对照组,对比血常规检测结果。
结果:放置4 h后,25 ℃与32 ℃环境下RDW显著高于对照组,差异有统计学意义(P<0.05)。
放置12 h后,32 ℃环境下平均MCHC显著低于对照组,差异有统计学意义(P<0.05)。
放置24 h后,25 ℃环境下HCT显著高于对照组,差异有统计学意义(P <0.05)。
结论:全血标本的保存温度与保存时间会影响血常规检测结果,为获得最佳检测结果,应在血液标本采集2 h内进行检测。
[Abstract] Objective:To analyze the influence of the preservation time and temperature of blood samples on blood routine examination results.Method:A total of 120 cases from January 2016 to December 2016 were randomly selected as the research object,three blood vessels were collected from each checker,and were placed in the preservation of 32 C water soluble box,25 DEG and 4 DEG C temperature box in the refrigerator,detected at different time respectively,with real-time detection value as control group,the results of blood routine examination were compared.Result:The RDW were significantly higher than that of the control group at 25 and 32 ℃after 4 h placement,the differences were statistically significant(P<0.05).After placing of 12 h,the average MCHC of the 32 ℃was significantly lower than that of the control group,the difference was statistically significant(P<0.05).After placing of 24 h,the HCT at the 25 ℃environment was significantly higher than that in the control group,the difference was statistically significant(P<0.05).Conclusion:The preservation temperature and storage time of whole blood specimen will affect the result of blood routine examination.In order to obtain the best test result,the blood sample should be collected in 2H for examination.[Key words] Whole blood specimen;Blood routine;Preservation time;Preservation temperature血常規检测为临床检验三大常规之一,可为疾病诊断提供可靠参考依据[1]。
全血标本保存时间和温度对血常规检测结果的影响分析
全血标本保存时间和温度对血常规检测结果的影响分析摘要:目的:血常规的检验结果容易受到客观因素的影响,本实验将探究保存时间和环境温度对结果的影响程度。
方法:随机选取部分全血标本,分别置于不同温度的保存箱中,在不同时间段进行血常规检测,记录和分析结果。
结果:血液标本的保存时间和保存环境温度对检测结果均有较大影响,检测结果的观察指标为红细胞分布密度,平均血红蛋白浓度和红细胞压积,实验后数据显示血液采集后在2h内进行检测结果较为准确。
结论:血常规检测应尽量在血液采集后2h内完成,如全血标本未来得及送检,需要将标本放置于4℃以下保存。
关键词:血常规;保存时间;保存温度血常规检测是门诊和临床治疗中的常规检测方法,其具有血液采集方便,检测时间较短,检测项目较多和检测结果精准的优点,可以为医护人员提供准确的数据参考,帮助医护人员更好的诊断和治疗患者。
但全血标本在样本采集完成后,需要经历送检的过程,在送检中,全血标本的保存时间和保存温度会影响血常规检测项目的指标和检测结果。
本实验将探究标本在送检过程中,其保存时间和保存温度对血常规检测的影响。
1 研究对象和实验方法1.1研究对象基本信息本实验将选取82名健康者的血常规标本为样本,健康者的全血标本均在医院体检中心中采集,其中体检者中男女比例为46:36,体检者群体的平均年龄在28岁左右。
1.2仪器与试剂本实验采用的检测仪器与使用试剂如表1所示。
1.3实验方法在常温下对82名研究对象进行全血标本的采集,医护人员将使用含抗凝剂的真空采血管和采血针采取研究对象的静脉血,每位研究对象将采集3份静脉血,分别放置于4℃冰箱,25℃温室和32℃水浴箱中,并在保存时间为1、2、4、6、8、12、24、48、72h时进行血常规检测,记录和比较检测结果。
2 结果2.1 RBC和HGB血常规检测指标中红细胞和血红蛋白数量在不同保存温度下随时间变化的检测结果如表2所示。
RBC和HBC的检测结果数量随着全血标本的保存时间变长而逐渐降低,且在同样的保存时间里,数量随之温度上升而逐渐升高,但变化程度和趋势不大,与及时测定结果较为接近。
肝功能检测中标本温度、溶血和储存时间对结果的影响分析
4.2、血液标本的保存及运送:血液标本采集后,需要确保试管的无菌、干燥与密封,贴好受检者资料标签,一般在血液标本采集后2h内送检,以确保标本的新鲜度,无法及时送入实验室检验的血液标本,一般会置入4℃左右的冰箱内进行低温保存。血液标本运送需要由专业运送人员完成,标本运送过程中严禁剧烈震动,预防红细胞异常溶解,以确保及时完全送入实验室。
肝功能检测中标本温度、溶血和储存时间对结果的影响分析
肝功能检测是血生化检查中的主要项目,主要检测指标有直接胆红素(DBiL)、总胆红素(TBiL)、谷草转氨酶(AST)、谷丙转氨酶(ALT)等,能够有效对肝脏的生理功能进行评定,同时明确肝脏病变情况,在肝功能异常相关疾病的诊断、评估、治疗与预后跟踪方面具有重要意义。肝功能生化检验以外周血为检验标本,故而检测的安全性、可复性较高,近年来伴随医学检验技术的不断发展,肝功能检测也向便捷化、自动化、精准化发展。目前肝功能生化检验中,重视检测数据的分析,以确保检验结果的准确性,而检验过程中发现,肝功能生化检验结果易受到标本情况的影响,导致结果出现假阳性、假阴性等情况,影响临床诊疗工作的开展。故而明确肝功能检测过程中影响结果的主要原因,是目前生化检验工作中的重点之一,本文主要就标本温度、溶血和储存时间对肝功能检测结果的影响及相关处理对策进行介绍分析。
4.4、检验质量控制:肝功能检测通过全自动生化分析仪完成,检验仪器的质量控制极为关键,需要重视检验仪器的定期维护与保养,确保仪器的工作性能,一旦出现仪器报警,需要立即明确原因,遇到无法排除的报警原因,需要立即联系设备科处理,以确保仪器的精密性。每日开展检验工作前,需要对仪器进行校对,做好准备工作,从而确保检验结果的准确性,开展检测工作时,需要严格遵循检验流程及操作规范,采用全自动生化分析仪配套试剂完成检验工作。
样本放置时间及温度对血氨检测的影响
样本放置时间及温度对血氨检测的影响发表时间:2017-06-27T13:00:12.563Z 来源:《医药前沿》2017年6月第17期作者:潘成明陈航华黄秋梅冯凌思余健全骆恒芳[导读] 血浆氨样本采集后应低温立即送检,并于0.5h检测,如因故不能及时检测,应将标本放置与4℃冰箱冷藏于2h内完成检测。
(广东省佛山市高明区人民医院检验科广东佛山 528500)【摘要】目的:探讨样本放置温度与时间对血浆氨检测结果的影响。
方法:将126个研究对象分别采集两份/人的样本,一份放置于室温作为观察组,另一份放置于4℃冰箱中作为对照组,分别检测其0h、0.5h、1h、2h、3h时的浓度。
结果:对照组和观察组血浆氨的浓度均随时间增长而升高,观察组结果在0.5h的结果与对照值(0h)之间无统计学差异(P>0.05),观察组血浆氨结果和对照组在1h、2h、3h结果相比均有统计学意义(P<0.05)。
对照组放置0.5h与1h时检测值与样本0h检测结果之间差异无统计学意义(P>0.05),对照组2h与3h检测结果与样本0h结果之间差异有统计学意义(P<0.05)。
结论:血浆氨样本采集后应低温立即送检,并于0.5h检测,如因故不能及时检测,应将标本放置与4℃冰箱冷藏于2h内完成检测。
【中图分类号】R446.11+2 【文献标识码】A 【文章编号】2095-1752(2017)17-0391-01 正常情况下,人体血浆氨的含量极低[1],血液浓度在10~47μmol/L之间。
血浆氨能通过血脑屏障,它的增高具有神经毒,能引发肝性脑病(肝昏迷)。
血浆氨结果的准确与否能直接影响临床医生对肝性脑病的诊断以及其疗效的观察。
因此,本文通过探究时间以及温度对血浆氨测定的影响给临床医生对血浆氨检测结果真实性的判断提供重要的应用价值。
1.材料与方法1.1 一般资料选取我院健康体检科的健康成年人血清126份,空腹采用肝素钠试管采血,每人两管,每管2mL。
保存温度、时间、溶血对血清标本中NSE测定的影响
保存温度、时间、溶血对血清标本中NSE测定的影响陈美华【摘要】Objective To explore the influence of storage temperature,time and hemolysis on the measurement of neu-ron-specific enolase in serum. Methods The levels of NSE in serum from normal people stored at 4℃ and minus 20℃respectively were measured and compared at that day,third day and fifth day by ELISA. Results Under the same storage temperature, the NSE level in serum which was stored for 3 days was significantly higher than that of that day (t=2.99, 6.90, P<0.05). The NSE level in serum which was stored for 5 days was significantly higher than that stored for 3days(t=1.97,2.04, P<0.05). When stored for 5 days, the NSE levels which was stored at 4℃ were significantly higher than that stored at minus20℃(t=4.67,P<0.05). There was a significant interaction effect between storage time and temperature on the serum levels of NSE (P<0.05). At minus 20℃ that day, 4℃ and minus 20℃ stored for 3 days, 4℃ and minus 20℃stored for 5 days, the NSE levels of hemolysis samples were significantly higher than that non-hemolysis except for at 4℃that day(t=2.16, 3.49, 2.60, 13.66, 8.42, P均<0.05). Conclusion The change of NSE level depend on different stor-age temperatures, detection times and hemolysis.%目的:探讨血清标本保存时间、保存温度和溶血对神经元特异性烯醇化酶(NSE)测定的影响。
储存温度与时间对血清标本生化检验结果的影响
储存温度与时间对血清标本生化检验结果的影响【摘要】目的探究温度和时间对血清标本检验结果的影响,从而来提升血清的鲜活度。
方法将血清标本分不密封、密封分别放置在不同的环境中保存1、2、4h后,检测病人11项生化指标ALT、AST、CK、TB、,ITP、Alb、TC、BUN、UA、Glu、P的值,并与放置前测定的值进行比较。
结果血清密封放置在各个温度下2h后无显著性改变;而无密封放置2O摄氏度4h后有9项结果增高,有显著性差异。
结论若要取得准确的资料,必须要及时观察血清的变化。
【关键字】储存温度,时间。
血清标本生化检验结果,影响引言随着生化仪器的更新,常规的检查在室内、室外普遍开展,质量控制逐渐得到重视。
为了了解一些外部因素对生化指标的影响,我们将在不同时间和不同温度下对血清指标进行测量,从而掌握在储存血清时需要注重的一些步骤。
一.资料和方法1.一般资料随机选取某一月份医院需空腹采血做常规生化检验的住院病人150例作为象,分为3组,每组5O例。
第一组男28例,女22例;年龄(35±3)岁。
第二组2例,例,年龄(32±5)岁。
第三组男23例,女27例,年龄(29±6)岁。
统计分析,病人的年龄、性别无显著性差异。
检测仪器为全自动生化分析仪[1]。
2.研究方法叮嘱病人在前一天晚七点后禁食、禁水,第二天清晨七点采血,一次性抽取病人肘部静血,然后进行分离血清后,将血清标本密封的和不密封的分别放置在35、2O、4摄氏度的环境中保存1、2、4h后进行测量。
最后进行观察。
3.统计方法将数据输入SPSS10,0软件包进行统计分析,采用配对t检验[4]。
二.结果为了检测储存温度对检测结果的影响,对血液样本分别进行了常温保存和冰箱冷藏。
并且对血液样本在48小时之内进行了6次检测。
1.测定结果的平均值温度白细胞(WBC)红细胞(RBC)血小板(PLT)血红蛋(HGB平均值F值平均值F值平均值F值平均值F值常温保存5.86.15.46.7181171372.冰箱冷藏4.71.34.75.91797.21301.7通过观察可以发现,常温保存和冰箱冷藏下,细胞的数量变化不是很明显,但常温保存下,白细胞2h后形态就开始发生变化;红细胞在1h后发生变化;血小板体积增大,1h后才趋于稳定。
血清标本保存时间的不同对生化检测结果的影响
血清标本保存时间的不同对生化检测结果的影响随着医学科技的不断进步,生化检测在临床诊断中扮演着越来越重要的角色。
而对于血清标本保存时间的不同对生化检测结果的影响,也成为了许多医学专家和研究人员关注的焦点之一。
本文将探讨不同保存时间对血清标本的影响,以及其对生化检测结果的影响。
一、血清标本的保存血清标本是生化检测的重要样本之一,它包含了大量的生化信息,可以帮助医生判断患者的疾病情况、诊断疾病并制定治疗方案。
而对于血清标本的保存,包括保存温度、保存时间等因素都会影响样本的质量。
通常情况下,血清标本在4摄氏度的冰箱中保存可以保持较好的质量,但是如果保存时间过长,也会对样本的质量产生影响。
1.保存时间短的影响在血清标本保存时间较短的情况下,一般来说,样本的质量不会受到太大影响。
但是在采集后的最初24小时内,血清标本中的生化成分可能会出现一些变化,这一点需要实验室工作人员在处理样本时特别注意。
如果保存时间过短,也可能会导致细菌或其他污染物的产生,进而影响检测结果的准确性。
在保存时间较长的情况下,血清标本的质量就会受到明显的影响。
长时间的保存会导致血清标本中的一些成分发生分解和变化,从而影响到生化检测的准确性。
长时间保存还可能导致冰冻融化循环,导致蛋白质的聚集和沉淀,进而影响到检测结果的准确性。
1.肝功能检测肝功能检测是临床常规检查项目之一,而肝功能指标包括丙氨酸氨基转移酶(ALT)、天门冬氨酸氨基转移酶(AST)、总胆红素(TBIL)、直接胆红素(DBIL)等。
对于这些指标来说,保存时间过长会导致血清中谷氨酸氨基转移酶、丙氨酸氨基转移酶等酶的活性下降,使得检测结果偏低,可能会造成一些临床诊断上的误判。
2.血脂检测血脂检测是评估心血管疾病风险的重要指标,而血清中总胆固醇(TC)、甘油三酯(TG)、高密度脂蛋白胆固醇(HDL-C)等是常规检测项目。
保存时间过长会导致血清中甘油三酯水平的升高,而总胆固醇和高密度脂蛋白胆固醇的水平则可能会降低,进而影响到心血管疾病的评估。
标本类型、储存时间和温度对血钾测定的影响评价
serum potassium detection.M ethods The 1 2 cases in the physical examinations in hospital from May 2017 to June 2017 were selected and their blood were collected under quiet and empty stomach.The sep— arate blood specimens were collected from contains glue and hepafin anticoagulant sample tube,centrifu- gal separation of serum and plasma af ter respectively at 4 ℃ 。20 。70 ℃ refr igerator storage.Repeated measurement of ser um potassium was conducted three times at 8 time points:1 h,3 h,6 h,24 h,48 h, 72 h,1 w and 2 w.The variation trend of seru m potassium content with time and temperature in different sample containers was analyzed.Results Two kinds of sample tube of potassium determination results in constant tem perature,the measured value with the extension of time showed a trend of slow decline and
血液标本体外放置时间和温度对尿酸检测结果的影响
血液标本体外放置时间和温度对尿酸检测结果的影响2008-09-27 05:26.尿酸;,,温度;,,时间摘要:目的研究血液标本体外放置时间和温度对尿酸测定的影响。
方法测定不同温度和时间条件下保存的血液标本的尿酸水平,观察与立即分离血清测定组比较有无显著性差异。
结果血液标本室温(25℃)下放置2 h以上尿酸结果有显著性变化(P<0. 05),4℃冰箱放置的标本随时间的延长无明显变化。
结论血液标本室温下体外放置随时间的延长,尿酸水平有显著下降趋势,为确保尿酸检测的准确性,采血后应及时分离血清或放4℃冰箱保存。
关键词:尿酸;温度;时间尿酸是通过黄嘌呤脱氢酶或黄嘌呤氧化酶降解嘌呤形成的最终代谢产物。
现已知血清尿酸与多种疾病有着密切关系,尿酸浓度增高可能是痛风、肾病、糖尿病、冠心病、高血压等潜在的危险因素[1,2]。
尿酸水平已成为健康体检者所关注的重要指标。
我们在常规检测过程中,发现不同血清分离时间对尿酸检测结果具有一定影响,因此,选取在我院健康体检者作为对象,观察了血液标本不同的血清分离时间和温度对尿酸测定结果的影响,现报道如下。
1 材料与方法1.1 仪器与试剂仪器为日立7600-010型自动生化分析仪。
尿酸 (UA)试剂为日本和光公司生产的液体双试剂,c.f.a.s定标液为 Roche公司产品(批号为167 218- 01),两个水平的室内质控血清为 AusBio公司产品(水平1批号为JN3871,水平2批号为JL4415)。
1.2 对象选取在我院健康体检者,清晨空腹采取静脉血,剔除溶血、脂血标本。
1.3 重复性实验用c.f.a.s定标液定标,两个水平的室内质控血清作尿酸的批内和日间重复性实验。
1.4 方法1.4.1 保存温度对尿酸的影响选取30名受检对象,空腹采取静脉血一式三份(各2 ml),一份立即分离血清测定尿酸,作为立即测定组;第二份放4℃冰箱封闭保存,第三份室温(25℃)封闭放置,24 h后分离血清测定尿酸水平;同时,为了解尿酸在分离后的血清中保存有无变化,将第一份测定后的剩余血清用1.5 ml离心管室温(25℃)保存,24 h后测定尿酸水平。
全血标本存放时间及温度对糖化血红蛋白检测结果的影响
全血标本存放时间及温度对糖化血红蛋白检测结果的影响【摘要】目的:研究全血标本存放时间及温度对糖化血红蛋白(HBA1c)检测结果的影响。
方法:选取2020年4月~2020年8月我院采集的4例患者静脉血标本,对其进行研究,分别存放在不同时间和不同温度状态下,对HBA1c的检测结果进行分析。
结果:全血标本在15~25℃存放三周、2~8℃存放三个月、-20℃存放三个月的HbA1c值与基准值比较的变化幅度比较明显(P<0.05);-70℃存放六个月的HbA1c值与基准值比较的变化幅度无明显差异(P>0.05)。
结论:全血标本的存放时间和温度对HBA1c检测结果有直接影响,因此要对存放时间和温度进行慎重处理。
【关键词】糖化血红蛋白;温度;全血标本;检测结果;存放时间糖化血红蛋白(HbA1c)是用于评价糖尿病患者血糖控制效果时非常重要的一个指标[1]。
HbA1c的检测反映了患者过去2~3个月的平均血糖水平,因此,HbA1c值的准确性直接对患者病情的诊断和控制产生影响。
有研究指出[2],临床上,在对HbA1c值检测过程中,全血标本存放的时间和温度对检测结果产生一定影响。
所以,本文选取2020年4月~2020年8月我院采集的4例患者的静脉血标本进行研究,分别存放在不同时间、不同温度下,对HBA1c的检测结果进行分析,现报道如下。
1 资料和方法1.1临床资料选取2020年4月~2020年8月我院采集的4例患者的静脉血标本作为研究对象,所有患者均采取全血标本,男3例,女1例,平均年龄23~55岁,平均年龄(40.2±3.2)岁。
纳入标准:①患者均签订知情同意书,自愿参与配合;②符合2型糖尿病诊断标准;③患者病例资料齐全。
排除标准:①儿童、青少年及孕妇群体;②出现糖尿病症状不到两个月患者;③服用类固醇、抗精神病药物。
1.2 方法将4例患者的静脉血标本均采取离子交换高效液相色谱法(HPLC)对全血标本实行HBA1c检测,检测仪器为LD-560糖化血红蛋白仪。
分析全血标本保存时间和温度对血常规检测结果的影响
分析全血标本保存时间和温度对血常规检测结果的影响发布时间:2022-01-20T02:21:48.351Z 来源:《健康世界》2021年23期作者:刘广[导读] 目的:分析全血标本保存时间和温度对血常规检测结果的影响刘广牡丹江市第一人民医院黑龙江牡丹江 157000摘要:目的:分析全血标本保存时间和温度对血常规检测结果的影响。
方法:随机抽选2020年7月~2021年3月期间于本院接受全血血常规检验者共80例为研究对象,行对比性临床研究,依据分层随机化分组法划分组别,A组、B组各40例。
全血样本采集后,A组随机选择10份(A1)立即上机检验,其余样本在室温下保存2h(A2)、4h(A3)、8h(A4)时各取10份上机检验;样本采集后,B组随机选择10份(B1)立即上机检验,其余样本在冷藏环境下2h(B2)、4h(B3)、8h(B4)时各取10份上机检验。
统计各组血常规检验结果差异。
结果:(1)A组血常规检验结果差异:A1、A2组RBC、WBC、PLT及Hb组间对比无显著差异(P>0.05);A3组PLT高于A1组,差异显著(P<0.05),RBC、WBC、Hb较A1组无统计学差异(P>0.05);A4组RBC、PLT及Hb均高于A1组,WBC低于A1在,差异显著(P>0.05)。
(2)B组血常规检验结果差异:B1、B2组RBC、WBC、PLT及Hb组间对比无显著差异(P>0.05);B3组PLT高于对照组,差异显著(P<0.05);B4组RBC、PLT及Hb均高于B1组,WBC低于B1在,差异显著(P>0.05)。
结论:全血标本保存时间和温度条件对血常规检验结果存在明确影响性,需在血常规检验实施中,严格保存全血标本、及时送检,确保检验结果真实性。
关键词:全血标本;保存时间;温度环境;血常规检测血常规检验是临床开展较为广泛的实验室检验项目,可在经采集受检者x全血样本后,经对症分析相关血常规检验指标后,对患者病情的基础诊断予以初步参考资料,临床应用意义显著,但在实际检验实施中,受样本保存时间及保存环境条件限制,或可导致血常规检验结果误差,降低临床检验参考性[1] 。
标本存放温度和时间对ALT、GLU 检测结果的影响分析
标本存放温度和时间对ALT、GLU 检测结果的影响分析摘要】目的研究分析标本不同存放温度、存放时间对ALT 和GLU 检测结果的影响,促进标本检测结果更准确。
方法:选择2012 年3 月~2013 年3 月800 份血液标本进行本次实验,将每位患者的标本均分成三大份,I 份和Ⅱ份每份分为两小组。
其中I 份中a 组b 组进行不同温度测定,Ⅱ份中,A 组B 组对标本存在时间进行测定,Ⅲ份立即进行测定。
以Ⅲ份作为标准,对比观察每份ALT、GLU 检测结果。
结果:不同温度中,a 组b 组检测,结果差异明显,P<0.05,差异有统计学意义;不同存放时间中,A 组与B 组差异明显,P<0.05,差异有统计学意义。
结论:标本存在时间长,温度升高,对ALT、GLU 检测结果有明显的影响,需要引起注意。
【关键词】标本;检测;温度;时间;ALT;GLU虽然目前临床上在血液标本存放时间与存放温度会影响检测结果上已经有各种的定论,但各种结论残差不齐,其参考价值较低。
王龙之认为,如果标本存放的时间越久或存放的温度越高,血液标本生化结果出现异常的几率就越高[1]。
为了更好地分析标本存放温度与存放时间对ALT、GLU 检测结果的影响,我院对于2012 年3 月至2013 年3 月期间采集的800 份血液标本进行试验分析,现报道如下。
1 资料与方法1.1 一般资料选取我院于2012 年3 月至2013 年3 月期间采集的800 份血液标本进行试验,将每位患者的标本均分成三大份,每份6mL,并置于无抗凝加盖试管中,离心标本。
其中将I 份分为两小组——a 组和b 组,对两组进行不同温度下的测定;将a 组置于4℃恒温环境中,将b 组置于25℃恒温环境中,测定时间都为72h。
将Ⅱ份也分为两小组——A 组和B 组,对两组进行不同存在时间的测定。
对A 组分别进行2、4、6、8h 的测定,对B 组分别进行12、24、48、72h 的测定。
而Ⅲ份将作为标准,立即进行测定。
标本放置时间及温度对血氨检测结果的影响
标本放置时间及温度对血氨检测结果的影响白巨明【摘要】目的:探讨血氨标本放置时间及温度对血氨结果的影响。
方法将100份标本离心后,使用干化学法检测其浓度后,将每份标本分装成2份,分别置于室温和4℃冰箱冷藏条件下放置,检测其0.5、1、2、3 h 时血氨的浓度。
结果标本放置时间越长,血氨浓度越高,标本室温放置0.5 h 后与标本检测对照值(0 h)之间差异无统计学意义(P>0.05),放置1、2、3 h 后血氨浓度与标本检测对照值(0 h)之间差异有统计学意义(P<0.05)。
4℃冰箱冷藏放置0.5、1 h 后的血氨浓度与标本检测对照值(0 h)之间差异无统计学意义(P>0.05),放置2、3 h 后血氨浓度与标本检测对照值(0 h)之间差异有统计学意义(P <0.05)。
结论血氨标本采集后应立即送检,0.5 h 内完成检测,如不能及时检测,应离心后将血浆放置于4℃冰箱冷藏,2 h 内检测。
【期刊名称】《检验医学与临床》【年(卷),期】2015(000)019【总页数】2页(P2941-2942)【关键词】血氨;放置时间;存放温度【作者】白巨明【作者单位】海军总医院检验科,北京 100048【正文语种】中文血氨在健康人体内浓度极低[1],主要用于肝性脑病预测、辅助诊断和治疗效果判断,肝功能衰竭评价,肝性昏迷鉴别诊断,Reye综合征、3H综合征的诊断[2-3]。
因其对中枢神经系统具有毒性作用,也适用于伴有意识障碍的肝病,原因不明的意识障碍、怀疑高氨血症的婴幼儿。
血氨来源主要为食物蛋白质等含氮化合物在肠管内经细菌分解,氨基酸脱氨基和肠内细菌尿素酶分解尿素产生氨,并扩散入血,在肾脏与氢离子结合成铵盐由尿排泄[4]。
氨对中枢神经系统具有毒性作用,能使神经递质减少,能量代谢水平降低,造成脑细胞功能障碍,是诱发肝性脑病的因素之一[5-6];伴有肝硬化的肝性脑病80%有血氨升高。
血液放置、红细胞氨游离使血氨浓度升高。
PT和APTT检测标本放置温度及时间对结果的影响
PT和APTT检测标本放置温度及时间对结果的影响
刘晓娟
【期刊名称】《医学检验与临床》
【年(卷),期】2010(021)006
【摘要】@@ 凝血酶原时间(PT)用以反映外源性凝血因子是否异常,活化部分凝血酶原时间(APTT)用来反映内源性凝血因子是否异常.它们是止凝血功能最基本|,最常用的试验.PT,APTT测定的影响因素很多,标本保存温度及放置时间是其中很重要的一个方面.<全国临床检验操作规程>第三版规定:采血后APTT测定最迟不应超过2h;PT测定宜在1h内完成,4℃冰箱保存不应超过4h.但由于各种条件的限制,这在很多情况下难以实现.
【总页数】2页(P102-103)
【作者】刘晓娟
【作者单位】山东省莱州市人民医院检验科,山东莱州,261400
【正文语种】中文
【相关文献】
1.PT和APTT检测标本放置温度及时间对结果的影响 [J], 李济凯;吴建平;徐根云
2.标本采样部位、放置时间和温度对PT、APTT测定结果的影响 [J], 朱力芬
3.标本放置时间及溶血、乳糜血对PT和APTT的影响 [J], 康晓军
4.标本放置温度及时间对PT、APTT检测结果的影响 [J], 李济凯;吴建平;徐根云;
5.标本放置和离心时间对PT、APTT检测结果的影响 [J], 董菊子;胡秦妮;杨淑娟;曹晶晶
因版权原因,仅展示原文概要,查看原文内容请购买。
血标本保存时间及温度对电解质检测结果的影响
血标本保存时间及温度对电解质检测结果的影响程妙;高国生【期刊名称】《医药前沿》【年(卷),期】2022(12)2【摘要】目的:探讨血标本保存不同时间及温度对血清钾、钠、氯检测结果的影响。
方法:选取2021年4月—6月宁波华美医院门诊患者14例,每例患者采血14 m L,平均置于7支含有促凝剂的试管内,分别在即时、1 h(室温和4℃)、2 h(室温和4℃)、3 h(室温和4℃)离心吸取血清检测钾、钠、氯;对检测结果进行统计学分析。
结果:经重复测量ANOVA分析,钾、钠、氯在不同条件下的检测结果差异均有统计学意义(P均<0.001)。
Turkey多重比较分析显示,随着放置时间的延长,K离子结果(室温和4℃)与即时检测相比逐渐显著升高(P均<0.05);钠离子放置2、3 h(室温和4℃)后与即时检测相比,结果升高(P均<0.05);C l离子放置1 h(室温和4℃)后结果降低(P均<0.05),但放置2 h(4℃)和3 h(室温和4℃)后恢复到即时水平。
结论:存储温度(室温和4℃)、放置时间(3 h内)的不同可对血清电解质的检测结果带来差异,但对临床决策并无影响。
【总页数】3页(P13-15)【作者】程妙;高国生【作者单位】宁波大学医学院;中国科学院大学宁波华美医院检验科【正文语种】中文【中图分类】R363.1【相关文献】1.不同保存时间及温度对全血标本血常规检测结果的影响分析2.全血标本保存时间和温度对血常规检测结果的影响分析3.全血标本保存时间和温度对血常规检测结果的影响分析4.全血标本保存时间和温度对血常规检测结果的影响5.全血标本保存时间的温度对血常规检测结果的影响因版权原因,仅展示原文概要,查看原文内容请购买。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
保存温度和时间对外送标本检测影响的评估作者:金正伟罗惠明余智超来源:《中外医学研究》2014年第22期【摘要】目的:探讨保存温度和时间对外送标本检测结果的影响,评估外送项目结果的可靠性,确定本科室的部分外送项目。
方法:选取不同时间和保存温度分组对外送项目用雅培i2000进行测试。
结果:HEV-IgG、T3、T4、TSH、CA125、性激素6项外送对结果影响不大。
InS、NSE、F-PSA、IgA外送对结果影响较大。
结论:尽力开展不能外送的项目,保证检验质量。
【关键词】温度;时间;外送标本中图分类号 R446.1 文献标识码 B 文章编号 1674-6805(2014)22-0050-03Evaluation on the Effect of Temperature and Time for Delivery Specimens/JIN Zheng-wei,LUO Hui-ming,YU Zhi-chao.//Chinese and Foreign Medical Research,2014,12(22):50-52【Abstract】 Objective:To investigate the effect of storage temperature and time for delivery specimens detection result,reliability evaluation of transmission project results,determine the undergraduate office part transmissionproject.Method:Different time and temperature blockforeign projects was tested using the Abbott 2000i.Result:HEV-IgG,T3,T4,TSH,CA125,sex hormone had little effect on the results.InS,NSE,F-PSA,IgA delivered a greater impact on the results.Conclusion:Carrying out can’t send project,ensure the inspection quality.【Key words】 Temperature; Time; Delivery specimensFirst-author’s address:The People’s Hospital of Anlu City,Anlu 432600,China目前各基层医院均存在外送标本检测误区,认为凡本院不能检测的项目或开展此项目经济效益不良一切外送,为了保证外送标本的检验质量,笔者对一些常见的外送项目会同外送的单位一起进行为期一年的评估。
评估结果是有些项目是能外送,在满足标本正常处理程序标本检测几乎不受时间和温度影响,有些项目是不能外送的,在满足标本正常处理程序标本检测差异有统计学意义。
笔者所在医院组织技术力量开展此项目,如本院实在不能开展的,要求患者亲自到上级医院进行相关方面的检测,以确保检验结果的准确可靠,防止误诊、漏诊,甚至医疗事故的发生。
所以笔者所在科室连续派人到外送单位就相关的项目学习、实验及对比性研究,分析医院具体外送项目占比,针对性地评估。
现报道如下。
1 资料与方法1.1 一般资料2011-2012年笔者所在医院外送标本3413例,其中血液标本3373例,尿标本35例,骨髓标本5例。
检测项目多为免疫项目,次为生化检测。
肝炎系列259例(7.6%),甲状腺功能474例(13.9%),糖尿病系列301例(8.8%),肿瘤病系列2238例(65.6%),性激素105例(3.1%),免疫功能36例(1.1%)。
肝炎系列中占主导外送为戊肝抗体,HCV-RNA;糖尿病系列中以InS为主,肿瘤系列占主导为CA系列、NSE、PSA;免疫功能以免疫球蛋白、ENA为主。
1.2 方法1.2.1 外送标本分析前质量控制为了保证外送标本的质量,笔者所在医院对委托实验室做整体质量评估,得到质量保证的同时,分析前标本采集保存处理显得尤为重要,笔者所在医院同委托方对常见外送检测项目进行存放温度和时时间对结果影响的评估。
1.2.2 方法笔者所在检验科模仿标本外送标本检测一切条件,采用化学发光法检测各项标志物,减少各项影响因素,包括分析前、分析中和分析后各个阶段的影响因素进行分析,也包括试剂、生理因素、钩状效应、嗜异性抗体等均会对结果造成不同程度化学发光法检测的影响因素[1]。
只对标本的采集后处理、标本的保存时间和保存温度对标本检测的影响,使用雅培i2000,按仪器操作规程操作,使用配套试剂测定。
2 结果2.1 肝炎系列2.2 甲状腺功能检测2.3 糖尿病系列InS评估3 讨论外送标本对临床检验资源的合理有效应用,虽然对外送标本严格按《检验标本采集手册》要求采集、分离,将饮食、生理状态等采集因素排除在外,但大多数医院标本采集以后就交给外送单位的标本收取员来处理,在乡镇医院调查其医院对标本处理情况,发现根本没有作任何处理,对温度和保存时间对标本影响因素基本没考虑,在二甲县市级医院和二甲以下的乡镇等医院均没引起重视。
标本收取员对标本处理也存在问题,没有记录标本采集和处理时间,标本保存的温度不能控制在2 ℃~6 ℃。
外送标本的保存温度如何控制,考察发现采用现代物流的方法很难控制温度为2 ℃~6 ℃,李明等[5]的医学检验标本收集运送车就是一个很好的探索。
保证运送恒定温度是减少影响结果重要因素之一[6]。
标本从采集到检测保存时间也影响检验结果,检测中心辐射各医院时间差为2~4 h,在途中消耗时间为1~2 h,每个标本从采集到检测中心检测6~7 h,时间之长,途中温度控制都是问题,因此评估极为重要[7-15]。
笔者所在医院评估外送项中占比比较大的委托检测项目,而占比比较小的标本外送检测项目以后进一步进行评估。
通过评估发现:(1)低浓度戊型肝炎抗体IgG在25 ℃保存2 d有1例变为阴性,4 ℃保存4 d有1例转阴,可能是标本放置时间过长导致其IgG或污染或变性失活。
(2)虽然甲状腺激素血清测定2个工作日内完成不受影响,但用血清标本和血浆标本检测是有明显差异,血浆标本在第1天和第2天测定有明显差异。
(3)肝素抗凝血InS检测随时间越长其值逐渐降低,故要在1 h内完成检测,是不能外送的,如若外送,需用分离胶管分离血清,但也需在4 h内完成检测。
(4)NSE的检测4 ℃保存24 h以外结果检测差异有统计学意义,而在25 ℃超过6 h结果检测有统计学意义。
因为NSE半衰期为1 d,NSE检测是不易外送的,如要外送,易应真空凝胶促凝管或普通塑料管采血。
(5)PSA检测,在4 ℃ 24 h内检测无统计学差异,而在25 ℃ 4 h以外和4 ℃ 24 h以外检测均有统计学差异,因为PSA半衰期为2~3 d,保存时间对标本检测结果的影响较大,同样不易外送。
(6)免疫球蛋白检测标本少,因而检测周期长,在4 ℃ 4 d只有IgA含量明显升高,在25 ℃保存2 d以上测得结果亦升高,因此标本要4 ℃保存。
所以急需医院开展不能外送这些项目,保证检验质量。
而二甲以下的乡镇等医院不应盲目外送标本到省级,而应尽量及时送到当地二甲医院完成检测,在当地二甲医院未开展的尽量让患者到上级医院去检查,确保标本检测质量,减少误诊,减少纠纷,确保医疗安全。
参考文献[1]吴慧玲.化学发光法检测肿瘤标志物的影响因素[J].中国保健营养,2012,22(12):2339.[2]林明,刘淑芹,肖丽珍.标本保存温度及放置时间对胰岛素检测的影响[C].玉溪市第八届检验医学学术年会暨科技成果扩广会论文汇编,2005.[3]吴健明.影响肿瘤标志物检测的因素[J].中华检验医学杂志,2005,28(4):352-355.[4]张亚松,肖登岩,麦富巨.温度时间及溶血对全血标本中NSE测定的影响[J].医学临床研究,2008,25(7):1193-1194.[5]李明,刘跃平,杨明,等.医学检验标本收集运送车的研制[J].中国医疗设备,2012,27(7):122-123,138.[6]谭立明.ELISA法检测的影响因素及其对策[J].实验与检验医学,2013,31(4):300-305.[7]邱燕英.两种标本处理方法对电化学发光法测定甲状腺激素影响的观察[J]. 中外医学研究,2013,11(11):36-37.[8]张丽花.标本的不同处理对胰岛素检测结果的影响探讨[J].中外医学研究,2013,11(27):39.[9]刘佚.血清标本放置时间和温度对部分生化项目结果的影响[J].中国医学创新,2013,10(28):86-88.[10]张慧涨,方强.标本的不同处理对胰岛素检测结果的影响[J].中国临床医学,2010,17(6):901-902.[11]武春梅,李玲,徐丽萍,等.溶血和标本保存条件对血清NSE检验结果的影响[J].国际检验医学杂志,2013,34(19):2591-2593.[12]仇彩霞,江崇才,王盛楠,等.影响神经元特异性烯醇化酶的新因素[J].青岛医药卫生,2013,45(1):19-21.[13]刘国瑞,罗冰,郑田,等.血清贮存对前列腺特异性抗原检测结果的影响[J]. 中华男科学杂志,2013,18(7):637-641.[14]陈少莲,马晓桂,李瑞莹.血清免疫球蛋白测定结果与保存时间及温度关系探讨[J].国际检验医学杂志,2013,34(8):1024-1025.[15]刘波.外送标本分析前质量控制中的特殊要求[J].国际检验医学杂志,2011,32(3):426-432.(收稿日期:2014-04-25)(编辑:程旭然)。