DC POWER操作指导书

合集下载

Recom-Power DC DC 转换器产品说明书

Recom-Power DC DC 转换器产品说明书

DC/DC Conv erterUL62368-1 (pending)CSA/CAN C22.2 No. 62368-1 (pending)IEC/EN62368-1 (pending)IEC/EN60601-1 (pending)RxxCTxxS FeaturesRegulatedConvertersSelection GuidePartNumberInputVoltage Range[VDC]SelectableOutput Voltage[VDC]OutputPower[mW]Efficiencytyp. (1)[%]R05CT05S 4.5-5.5 3.3 or 5500600.5 Watt16-Pin SOICSingle Output DescriptionLow cost, low profile, 500mW SMD isolated DC/DC single output converter ideal for applicationssuch as communication, current sensing, and medical applications which require robust isolation.The R05CT05S is a single solution with 5V input and a user-definable single, regulated 3.3V or 5Voutput. There is no minimum load requirement. Standard isolation is 5kVAC/1min with a 2MOPP ratingfor medical applications. The operating temperature is from -40°C up to +140°C with derating.Model Numberingnom. Input Voltagenom. Output VoltagePackaging (2)S ingle OutputR__CT__ S-__Notes:Note2: add suffix “-CT” for bag packaging for more details refer to “PACKAGING INFORMATION”without suffix, standard tape and reel packagingNotes:Note1: nom. V IN= 5VDC, V OUT set to 5VDC, load= 100mARoHS2+compliantREACHcompliantSpecifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)204010060120801401601008060409070503020100E f f i c i e n c y [%]Output Load [mA]0204010060120801401601008060409070503020100E f f i c i e n c y [%]Output Load [mA]V OUT = 3.3VDCV OUT = 3.7VDCSYNC FUNCTION (4)ParameterConditionMin.Typ.Max.SYNC Pin Input Current SYNC Voltage= 5VDC 0.02µA 1µA SYNC OK Output Voltage I SYNC_OK= -2mA 150mVSYNC OK pin leakage currentV SYNC_OK= 5VDC1µAREGULATIONParameterConditionMin.Typ.Max.Output Voltage AccuracyV OUT set to 5VDC; load= 0mA to 75mA, V IN = 4.5VDC 4.7VDC 5VDC 5.3VDC V OUT set to 5VDC; load= 0mA to 100mA, V IN = ≥5VDC 4.7VDC 5VDC 5.3VDC V OUT set to 5.4VDC; load= 0mA to 60mA, V IN = 4.5VDC5.1VDC 5.4VDC 5.7VDC V OUT set to 5.4VDC; load= 0mA to 90mA, V IN = ≥5VDC 5.1VDC 5.4VDC 5.7VDC V OUT set to 3.3VDC; load= 0mA to 110mA, V IN = 4.5VDC 3.1VDC 3.3VDC 3.5VDC V OUT set to 3.3VDC; load= 0mA to 150mA, V IN = ≥5VDC 3.1VDC 3.3VDC 3.5VDC V OUT set to 3.7VDC; load= 0mA to 100mA, V IN = 4.5VDC 3.5VDC 3.7VDC 3.9VDC V OUT set to 3.7VDC; load= 0mA to 130mA, V IN = ≥5VDC3.5VDC3.7VDC 3.9VDCLine Regulation low line to high line 1%Load Regulation0% to 100% load1.5%PROTECTIONSParameterCondition ValuesShort Circuit Protection (SCP)power limiting, continuous protectionShort Circuit Input Current V IN = 4.5VDC215mA V IN = 5VDC 240mA V IN = 5.5VDC 260mA Isolation Voltage1 minute5kVACcontinued on next pageNotes:Note4: Synchronous clock input pin. Provide a clock signal to synchronize multiple RxxCTxxS devices or connect to -V IN for standalone operation using the internal oscillator. If the SYNC pin is left open it should be separated from any switching noise to avoid false clock coupling. Active-low, open-drain diagnostic output. Pin is asserted LOW if an no external SYNC clock or one that is outside of the operating range of the RxxCTxxS is detected. In this state, the external clock is ignored and the DC-DC converter is clocked by the device’s internal oscillator. The pin is in high-impedance if a good clock is applied on SYNC.Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)Parameter Condition Values Maximum repetitive peak isolation voltage 1.414kV peakMaximum working isolation voltage1kVAC 1.414kVDCMaximum transient isolation voltage 1 minute7.071kV peak Maximum surge isolation voltage according IEC62368-1= 1.2/50us 6.25kV peak Isolation Resistance VISO= 500VDC, 25°C1012W typ. Isolation Capacitance 3.5pF typ. Insulation Grade reinforced Common mode transient immunity±100V/ns Internal Clearance solid insulation>0.12mm External Creepage>8mm Distance through the insulation minimum internal gap (internal clearance)>120µm Comparative tracking index DIN EN 60112 (VDE 0303-11); IEC 60112>600V Insulation Material Group according to IEC 60664-1ISpecifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH)reel (diameter + width)tape and reel (carton)Ø330.0 + 16.4mm height350.0 x 350.0 x 43.0mm moisture barrier bag (“-CT”)100.0 x 100.0 x 30mmPackaging Quantitytape and reel500pcs moisture barrier bag (“-CT”)10pcsStorage Temperature Range-65°C to +150°C The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorizeduse of RECOM products in such safety-critical applications.。

Agilent 6030A-GSA DC Power Supplies数据手册说明书

Agilent 6030A-GSA DC Power Supplies数据手册说明书

6032A-GSA6030A-GSA6033A-GSA6038A-GSAAgilent 6030 Series Single-Output, DC Power Supplies 200 W & 1000 W, Autoranging; GPIBData SheetThis series of 200 watt and 1000 watt DC power supplies take the place of multiple power supplies in your test system by providing maxi-mum power at a variety of operating points.Industry standard SCPI commands and VXI plug&play drivers make system integration easy. Using the serial link, up to 16 power supplies can be con-nected through one GPIB address. These power supplies have excellent electrical efficiency, making them a good choice for large systems.• Autoranging outputs providemaximum power at a variety ofoperating voltages• Analog/resistance control of outputvoltage and current• Series and auto-parallel connectionsof multiple supplies• Built-in measurements and advancedprogrammable features• Protection features to ensure DUTsafetyV1I1I2I3VoltsP1P2P3AmpsV2V3Autoranging Output2Supplemental characteristics for all model numbersRemote sensing: Up to 2 V drop in each lead. Voltage regulation specifi-cation met with up to 0.5 V drop, but degrades for greater drops.Modulation: (analog programming of output voltage and current)Input signal: 0 to 5 V or 0 to 4 kΩSoftware driver: VXI plug&play Size:6030A–32A, 6035A:425.5 mm W x 132.6 mm H x 503.7 mm D (16.75 in x 5.25 in x 19.83 in).6033A, 6038A:212.3 mm W x 177.0 mm H x 516.4 mm D (8.36 in x 6.97 in x 17.87 in).Warranty:One yearSpecificationsAgilent Models: 6030A, 6031A, 6032A, 6035A3Agilent Email Updates/find/emailupdatesGet the latest information on the products and applications you select.Agilent Channel Partnersw w w /find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.For more information on AgilentTechnologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:/find/contactusAmericasCanada (877) 894 4414 Brazil (11) 4197 3600Mexico 01800 5064 800 United States (800) 829 4444Asia Pacific Australia 1 800 629 485China 800 810 0189Hong Kong 800 938 693India 1 800 112 929Japan 0120 (421) 345Korea 080 769 0800Malaysia 1 800 888 848Singapore 180****8100Taiwan 0800 047 866Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15Finland 358 (0) 10 855 2100France 0825 010 700**0.125 €/minuteGermany 49 (0) 7031 464 6333 Ireland 1890 924 204Israel 972-3-9288-504/544Italy 39 02 92 60 8484Netherlands 31 (0) 20 547 2111Spain 34 (91) 631 3300Sweden 0200-88 22 55United Kingdom 44 (0) 118 927 6201For other unlisted countries:/find/contactusRevised: January 6, 2011Product specifications and descriptions in this document subject to change without notice.© Agilent Technologies, Inc. 2012Published in USA, July 30, 20125990-9297EN /find/6030Agilent Advantage Services is committed to your success throughout your equip-ment’s lifetime. To keep you competitive, we continually invest in tools andprocesses that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world./quality/find/advantageservicesQuality Management SystemQuality Management Sys ISO 9001:2008DEKRA Certified Ordering information6030 Series power supplies ship with product reference CD-ROM including: VXIplug&play drivers, operating manual, service manual, quick start guide, and application notes.Opt 001 Front panel has only lineswitch, line indicator, and OVP adjust (6030A–33A and 6038A only)Opt 100 87 to 106 VAC, 48 to 63 Hz (power supply output is derated to 75%)Opt 120 104 to 127 VAC, 47 to 63 Hz Opt 220 191 to 233 VAC, 48 to 63 Hz Opt 240 209 to 250 VAC, 48 to 63 Hz Opt 0L1 Printed operating manual (in English)Opt 0B3 Printed service manual (in English)Opt J01 Stabilization for loads up to 10 Henries (not available on 6033A)A ccessories5080-2148 Serial link cable, 2 m (6.6 ft)1494-0060 Rack slide kitE3663AC Support rails for Agilent rack cabinetsFor models: 6033A and 6038A:1CM001A*: Rackmount flange kit 177.0 mm H (4U) - one bracket, one half-module bracket1CM034A* Rack mount flange kit 177.0 mm H (4U) - two flange brackets and lock link kit for mounting two 6033A or 6038A units side by side.For models: 6030A, 6031A, 6032A, 6035A 1CM003A*: Rackmount flange kit 132.6 mm H (3U) - two flange brackets 1CP002A*: Rackmount flange andhandle kit 132.6 mm H (3U) - two brack-ets and front handlesApplication notes10 Hints for Using Your Power Supply to Decrease Test Time , 5968-6359E 10 Practical Tips You Need to Know About Your Power Products,5965-8239EAgilent DC Power Supplies for Base Station Testing,5988-2386EN*Support rails required6032A-GSA6030A-GSA6033A-GSA6038A-GSA。

DC直流电源操作规程

DC直流电源操作规程
6.检查风扇运转情况及检测调节直流稳压稳流电源的系统参数等;
编制
审核
批准
4.仪器使用完毕后,应将输出调节旋钮旋到最左端零输出位置,再将电源关闭;
5.当调节无输出时,过压指示灯亮,应关闭电源,顺时打开过压调节电位器,再缓缓调节电压调节电位器;
注意事项:
1.禁止超负载使用:直流稳压稳流电源的最大启动负载最好控制在80%之内,如果超载使用,会严重影响电源的使用寿命;
2.直流稳压稳流电源的场所摆放应避免阳光直射,并留有足够的通风空间,同时禁止在输出端口接带有传感性的负载;
3.设备使用人员在使用设备之前,要确认直流稳压电源安全接地,检查无误后,接通电源使用;
4.接通电源前: ⑴确认稳压电源面板上电源开关是否在“高”位Off状态。如果在“低”位On状态,则必须按到Off状态;
5.禁止超负载使用:直流稳压稳流电源的最大启动负载最好控制在80%之内,如果超载使用,会严重影响电源的使用寿命;
文件编号
版本
A/0
类别
DC直流电源操作规程
日期
标准文件
页码
1/1
作业流程
图片作业流程:1源自把外电路接到稳压电源接线柱上时,注意“+”、“-”极性不要接反;
2.将电源打开;调节电压(VOLTAGE)和电流(CURRENT)到所需的电压和电流值:粗调(COARSE)微调(FINE);
3.外电路试验时,应在输出电源接线中串接一个电源开关,以便于接通和断开外电路电源。禁止频繁地关闭和开启直流稳压稳流电源,否则,直流稳压稳流电源可能导致内部元器件的损坏;

[仿真]PowerDC直流压降仿真指导书

[仿真]PowerDC直流压降仿真指导书

Power DC PDN仿真指导书一、仿真文件格式转换1.文件转换软件介绍;双击,通过SPDLinks将PCB文件转换成Sigrity专用的仿真文件格式spd文件2.转换方法和设置;如下图,指定好被转换的PCB文件以及转换后spd文件的路径;设置好转换文件用的相关文件路径,记得保存设置结果。

3.文件格式转化;设置好相关路径后可以启动文件转换程序,待完成后可以到spd文件的路径下获取文件;二、仿真设置1.启动Power DC软件双击,进入Power DC主界面,点击,创建仿真任务。

选取模式,接下来导入仿真文件,进行仿真设置。

2.Power DC仿真设置2.1 仿真叠层和pad stack设置Pcb转成Spd文件过程中,会将pcb的相关叠层设置一并转换过来;因此导入spd文件后会直接生成相关的叠层,建议直接在allegro里面设置好叠层,避免后期重复设置。

Via Plating Thickness Setup: edit>pad stack library 输入过孔镀铜厚度2.3 仿真网络设置首先,选择需要仿真的电源网络,将其从信号网络类别转换到PowerNets类别中;将所有GND网络(包含单点接地的GND网络)转换到GroundNets类别中,同时将除power和GND 两类以外的网络全部disable掉。

2.4 设置仿真端口直流IR Drop仿真需设置源端和负载端,以便计算从源端到负载端通路上的直流压降,进而计算出通路的直流阻抗。

Source sink选择的原则:BUCK电源source选择在反馈线处电容或电感处设置LDO电源source选择在PMU出来的管脚处设置2.4.1 电流源端设置通常源端选用自动生成的方式,在之前enable的网络中进行选择;电压同一设置为1V,Tolerance不设置;以此类推将需要仿真的网络全部设置好。

如自动无法产生端口,可以通过手动方式,设置电流源端口;手动端口设置可以直接通过网络选择整体芯片自动生成端口。

PowerDC操作练习_100621

PowerDC操作练习_100621


23
Voltage电压
Show Results>Voltage & Current Tables>VRM
Voltage中包含有仿真得到的VRM结果 Actual Current是指VRM上实际输出的电流,大 小等于各个Sink抽取的电流之和 其他信息均为之前的输入信息
பைடு நூலகம்
24
Sink电压
8
选择电源/地网络

点击Select Pwr/Gnd Nets,选择要仿 真的电源网络和地网络 界面的右边将出现Net Manager网络管 理器窗口 激活电源网络,把他们放在 PowerNets 的分类中;激活地网络,把他们放在 GroundNets的分类中 如果封装或PCB翻译完之后电源地网络 属性为普通的信号分类,没有位于上述 PowerNets和GroundNets中,则必须通 过点击右键的Assign To PowerNets或 Assign To GroundNets将网络正确分类


15
Model的含义

Equal Voltage是指Sink上所有的电源管脚和地管脚上的电 压都相等。 Equal Current是指Sink上所有的电源管脚和地管脚上的电 流都相等。一旦选择了Equal Current就必须设置P/F Mode,是Average还是Worst,其具体含义见下页。此模 型最常用。 Unequal Current是指Sink上所有的电源管脚和地管脚上的 电流都不等。一旦选择了Unequal Current就必须在 Current Mapping File中指定包含芯片各管脚的电流文件。 此模型用的较少。

1. 2.
3.
19

SA-250 PERKINS 柴油引擎驱动 DC 电缆焊电源操作者手册说明书

SA-250 PERKINS 柴油引擎驱动 DC 电缆焊电源操作者手册说明书

SA-250 PERKINSDiesel Engine Driven DC Arc Welding Power SourceOPERATOR’S MANUALFor use with machines having Code Number 10073 or 10073CV: 10074IM518-AOctober, 2000Safety Depends on YouLincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought-ful operation on your part.DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT.And, most importantly, think before you act and be careful.Copyright © 2000 Lincoln Global Inc.This manual covers equipment which is nolonger in production by The Lincoln Electric Co. Speci cations and availability of optional features may have changed.Mar‘95for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you!Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.The level of seriousness to be applied to each is explained below:vvGENERAL DESCRIPTIONThe SA-250 is a heavy duty engine-driven DC arc welding power source capable of providing constant current output for stick welding or DC TIG welding. With the addition of the optional Wire Feed Module for K1283-4, the SA-250 will provide constant voltage output for running the LN-25, LN-23P or LN-7 wire feeders. The Wire Feed Module is factory-installed on the K1283-5 SA-250.The SA-250 has a current range of 40-325 DC amps with a 60% duty cycle at 250 amps/40 volts. The units are also capable of providing 3 kVA of 115/230 volt, 60 Hertz AC auxiliary power.DESIGN SUMMARYControl PanelBoth the engine and the welder controls are located on one recessed panel at the auxiliary power alterna-tor end of the machine. The welder controls consist of a five step “Current Range Selector” switch and a “F ine Current Adjustment” rheostat. Each welder is equipped with a “Start” button and an “Idler Control”switch. The Perkins diesel uses a “Thermostart” but-ton, and has a “Stop” control.On this panel is also mounted an engine temperature gauge, a battery charging ammeter, an oil pressure gauge, and the three prong grounded type auxiliary power receptacle.Copper Shunt WindingsFor long life and dependable operation.Engine IdlerThe SA-250 is equipped with an electronic automatic engine idler. It automatically increases and decreases engine speed when starting and stopping welder or using auxiliary power. A built-in time delay permits changing electrodes before the engine slows to its low idle speed. The “Idler Control Switch” on the panel locks the idler in full speed position when desired.Auxiliary Power3.0 kVA of nominal 115/230V, 60 Hz, AC1. (See Optional Features for Power Plug Kits).(1)Output voltage is within ±10% at all loads up torated capacity.Welder EnclosuresThe complete welder is rubber mounted on a rugged steel base.The output terminals are placed at the side of the machine so that they are protected by the door. The output terminals are labeled (+) and (-).Remote ControlK924-1 (for K1283-4, -5) (Field Installed). Provides a receptacle switch and remote control box with 100 ft cord for fine current and OCV adjustment at the weld-ing site.Cranking SystemA 12 volt electric starter is standard.Air CleanerHeavy duty two stage dry type.MufflerA muffler to reduce engine noise is standard on the diesel engine units.Engine Hour MeterA meter to record the hours of operation.Diesel Engine ProtectionThe system shuts the engine down in the event of sudden low oil pressure or high coolant temperature.Power Plug Kit (K802C) Array• A power plug kit for the auxiliary power receptacles is available. (Provides a plug for each receptacle).Trailer (K913)Two-wheeled highway trailer with steel, torsion-bar axle, 54” (137cm) wheel track. Low sway, low center-of-gravity. Sturdy tread plate platform. Choice of 3 hitches. Add on fender & light package. For highway use, consult applicable local laws regarding possible additional requirements.Order:K913-1Base TrailerK913-2Ball HitchK913-3Lunette Eye HitchK913-4Clevis Pin HitchK913-5Fender & Light KitWire Feed Module (K623-1)The Wire Feed Module is field-installed on the K1283-4, and factory-installed on the K1283-5 to provide CV (constant voltage) output for semiautomatic welding. Output rated at 250 Amps at 35 Volts with a 60% Duty Cycle and 310 Amps at 32 Volts with a 35% Duty Cycle.DIMENSIONSSee dimension Print M8869-24 at the rear of this man-ual.Product Name Description Horsepower Operating Speeds Displacement Capacities Perkins D3.1523 Cylinder,4 Cycle,Water-Cooled Diesel Engine with Thermostart Glow Plug and Engine ProtectionFull Load:38.2 HP @ 1725 RPMFull Load:1725 RPM High Idle:1800 RPM Low Idle:1350 RPM152 Cu. in.(2.5 ltrs)Fuel:15 gals (57 ltrs)Oil:7.2 qts (6.9 ltrs)Water:10 qts (9.5 ltrs)MachineEngine(1) WFM = Wire Feed Module.(2) Based on a 10 Minute Period.SPECIFICATIONSCold Weather Starting-- When overnight tempera-Array tures are between 10°F (-12°C) and freezing, use the standard“Thermostart” starting system installed on all engines. F ollow the instructions on the nameplate and in the engine manual shipped with the welder. With fully charged batteries and the proper weight oil, the“Thermostart” system operates satisfactorily even down to about 0°F (-18°C).If the engine must be frequently started below 10°F (-12°C), it may be desirable to remove the “Thermostart” and install the optional ether starter kit. Installation and operating instructions are included in the kit. Use ether starting only when required because excessive use shortens engine life.Stopping the Perkins D3.152 Enginea) Turn the ignition control to “OFF”.At the end of each day’s welding, refill the fuel tank to minimize moisture condensation in the tank. Also, running out of fuel tends to draw dirt into the fuel sys-tem.Check the crankcase oil and radiator water level.The AC auxiliary power, supplied as a standard, has a rating of 3.0 kVA of 115/230V AC (60 Hz).With the 3.0 kVA, 115/230V AC auxiliary power, one duplex 115V grounding type receptacle (NEMA con-figuration 5-15R) is provided. F or the 230V AC power, one grounding type duplex receptacle is pro-vided (NEMA configuration 6-15R). The circuit is pro-tected with circuit breakers.The rating of 3.0 kVA permits a maximum continuous current of 13 amps to be drawn from the 230 volt duplex receptacle. Or a total of 26 amps can be drawn from the 115 volt duplex receptacle. The 115 volt duplex receptacle has a configuration which per-mits 15 amps to be drawn from either half. Therefore, on this machine, up to 15 amps continuous can be drawn from one half and the balance of 11 amps from the other half. The total combined load of all recepta-cles is not to exceed 3.0 kVA.An optional power plug kit is available. When this kit is specified, the customer is supplied with a plug for each receptacle. In this case, he will receive two 15 amp, 115 volt plugs (NEMA configuration 5-15P) and two 15 amp, 230 volt plugs (NEMA configuration6-15P).(1)See FLASHING THE FIELDS on following page.(1)FLASHING THE FIELDSAC Auxiliary Power:1. Stop the engine welder and remove the cover from the exciter.2. Turn the “Fine Adjustment Control” (rheostat) to “100” on the dial.3. Using a 12 volt automotive battery, connect its negative terminal to the negative brushholder. The negativebrushholder is the one nearest to the rotor lamination. See the wiring diagram. With the engine NOT running, touch the positive battery terminal to the positive brushholder. Remove the battery from the circuit.4. Replace the exciter cover. Start the welder and the generator voltage should build up.–20––21–S A -250 & 350-S A W I R I N G D I A G R A MN O T E : T h i s d i a g r a m i s f o r r e f e r e n c e o n l y . I t m a y n o t b e a c c u r a t e f o r a l l m a c h i n e s c o v e r e d b y t h i s m a n u a l . T h e s p e c i f i c d i a g r a m f o r a p a r t i c u l a r c o d e i s p a s t e d i n s i d e t h e m a c h i n e o n o n e o f t h e e n c l o s u r e p a n e l s . I f t h e d i a g r a m i s i l l e g i b l e , w r i t e t o t h e S e r v i c e D e p a r t m e n t f o r a r e p l a c e m e n t . G i v e t h e e q u i p m e n t c o d e n u m b e r ..–22–Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible ” of the arc welding industry.This printing will go fast so don ’t delay. Place your order now using the coupon below.The hardbound book contains over 750 pages of welding information, techniques and procedures. Much of this material has never been included in any other book.A must for all welders, supervisors, engineers and designers. Many welding instructors will want to use the book as a reference for all students by taking advantage of the low quantity discount prices which include shipping by 4th class parcel post.$15.00postage paid U.S.A. MainlandHow To Read Shop DrawingsThe book contains the latest information and application data on the American Welding Society Standard Welding Symbols. Detailed discussion tells how engineers and draftsmen use the “short-cut ” language of symbols to pass on assembly and welding information to shop personnel.Practical exercises and examples develop the reader ’s ability to visualize mechanically drawn objects as they will appear in their assembled form.187 pages with more than 100 illustrations. Size 8-1/2” x 11”Durable, cloth-covered board binding.$4.50postage paid U.S.A. MainlandNew Lessons in Arc WeldingLessons, simply written, cover manipulatory techniques;machine and electrode characteristics; related subjects,such as distortion; and supplemental information on arc welding applications, speeds and costs. Practice materials,exercises, questions and answers are suggested for each lesson.528 pages, well illustrated, 6” x 9” size, bound in simulated,gold embossed leather.$5.00postage paid U.S.A. MainlandNeed Welding Training?The Lincoln Electric Company operates the oldest and most respected Arc Welding School in the United States at its corporate headquarters in Cleveland, Ohio. Over 100,000stu-dents have graduated. Tuition is low and the training is “hands on ”For details write:Lincoln Welding School 22801 St. Clair Ave.Cleveland, Ohio 44117-1199.and ask for bulletin ED-80 or call 216-383-2259 and ask for the Welding School Registrar.Lincoln Welding SchoolBASIC COURSE $700.005 weeks of fundamentalsThere is a 10%discount on all orders of $50.00 or more for shipment at one time to one location.Orders of $50 or less before discount or orders outside of North America must be prepaid with charge, check or money order in U.S. Funds Only.Prices include shipment by 4th Class Book Rate for U.S.A. Mainland Only.Please allow up to 4 weeks for delivery.UPS Shipping for North America Only.All prepaid orders that request UPS shipment please add:$5.00For order value up to $49.99$10.00For order value between $50.00 & $99.99$15.00For order value between $100.00 & $149.00For North America invoiced orders over $50.00 & credit card orders, if UPS is requested, it will be invoiced or charged to you at cost.Outside U.S.A. Mainland order must be prepaid in U.S. Funds. Please add $2.00 per book for surface mail or $15.00 per book for air parcel post shipment.METHOD OF PAYMENT:(Sorry, No C.O.D. Orders)CHECK ONE:Name:_______________________________________________Please Invoice (only if order is over $50.00)Address:_______________________________________________Check or Money Order Enclosed, U.S. Funds only _______________________________________________Credit Card - Telephone:_______________________________________________Signature as it appears on Charge Card:Account No.Exp Date|_|_||_|_|______________________Month YearUSE THIS FORM TO ORDER:Order from:BOOK DIVISION, The Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199BOOKS OR FREE INFORMATIVE CATALOGS Telephone: 216-383-2211 or, for fastest service, FAX this completed form to: 216-361-5901.Lincoln Welding School Titles:Price Code QuantityCost(ED-80)New Lessons in Arc Welding $5.00L Seminar Information Procedure Handbook “Twelfth Edition ”$15.00PH (ED-45)How to Read Shop Drawings $4.50H Educational Video Information Incentive Management $5.00IM (ED-93) A New Approach to Industrial Economics $5.00NA James F. Lincoln Arc Welding The American Century of John C. Lincoln $5.00AC Foundation Book Information Welding Preheat Calculator $3.00WC-8(JFLF-515)Pipe Welding Charts $4.50ED-89SUB TOTALAdditional Shipping Costs if anyTOTAL COSTJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.JapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.••• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: 。

DC Power Relays (25-A Models) 产品说明说明书

DC Power Relays (25-A Models) 产品说明说明书

G 9E B -1DC Power Relays Capable of Interrupting High-voltage, High-current DC Load•Utilizes a unique gas-filled, fully sealed, non-ceramic construction achieved by using resin with a metal case. This reduces the need for special processing and materials that were required with previous models, resulting in a low-cost relay that is both compact and lightweight.•Smallest and lightest in its class at 25 × 60 × 58 mm and approximately 135 g.This is approximately half the volume and a third of the weight of other DC Power Relays in the same class (400 VDC, 25 A).*•The unique design of the contact switching component and permanent magnet for blowing out the arc eliminates the need for polarity in the main circuit (contact terminal). This improves ease of wiring and installation, and contributes to providing failsafe measures against incorrect wiring.*Based on our investigation as of December 2004.■Model Number Legend■List of ModelsNote 1.Two M4 screws are provided for the contact terminal connection.Note 2.Two M4 screws are provided for the coil terminal connection.■Ratings●CoilNote 1.The figures for the rated current and coil resistance are for a coil temperature of 23°C and have a tolerance of ±10%.Note 2.The figures for the operating characteristics are for a coil temperature of 23°C.Note 3.The figure for the maximum voltage is the maximum voltage that can be applied to the relay coil.●ContactsRoHS CompliantRefer to "DC Power Relays Common Precautions".ModelsTerminalsContact formCoil rated voltageModelCoil terminalsContact terminalsSwitching/current conduction modelsScrew terminals Screw terminals SPST-NO 12 VDC 24 VDC 48 VDC 60 VDC 100 VDCG9EB-1-BItemRated voltageRated current(mA)Coil resistance(Ω)Must-operate voltage (V)Must-release voltage(V)Maximum voltage(V)Power consumption(W)12 VDC 166.77275% max. of rated voltage10% min. of rated voltage130% of rated volt-age (at 23°C within 10 minutes)Approx. 224 VDC 83.328848 VDC 41.71,15260 VDC 33.31,800100 VDC205,000ItemResistive load G9EB-1(-B)Rated load25 A at 250 VDCRated carry current25 A Maximum switching voltage 250 V Maximum switching current25 AG9EB-@-@-@-@— — — —12 341.Number of Poles 1: 1 pole2.Contact Form Blank: SPST-NO3.Coil Terminals B: M4 screw terminals4.Special FunctionsG9EB-1DC Power Relays (25-A Models)G 9 E B -1■CharacteristicsNote.The above values are initial values at an ambient temperature of 23°C unless otherwise specified.*1.The contact resistance was measured with 1 A at 5 VDC using the voltage drop method.*2.The insulation resistance was measured with a 500-VDC megohmmeter.*3.The impulse withstand voltage was measured with a JEC-212 (1981) standard impulse voltage waveform (1.2 × 50 μs). *4.The mechanical endurance was measured at a switching frequency of 3,600 operations/hr.*5.The electrical endurance was measured at a switching frequency of 60 operations/hr.*6.These values are for when a varistor is used as the protective circuit against reverse surge in the relay coil.Using a diode will reduce theswitching characteristics.Item Model G9EB-1(-B)Contact resistance *130 mΩ max.Contact voltage drop0.1 V max. (for a carry current of 25 A)Operate time30 ms max.Release time15 ms max.Insulationresistance *2Between coil and contacts1,000 MΩ min.Between contacts of the same polarity1,000 MΩ min.DielectricstrengthBetween coil and contacts2,500 VAC, 1 minBetween contacts of the same polarity2,500 VAC, 1 minImpulse withstand voltage *34,500 VVibrationresistanceDestruction10 to 55 to 10 Hz, 0.75-mm single amplitude(Acceleration: 2.94 to 88.9 m/s2)Malfunction10 to 55 to 10 Hz, 0.75-mm single amplitude(Acceleration: 2.94 to 88.9 m/s2)ShockresistanceDestruction490 m/s2Malfunction100 m/s2Mechanical endurance *4100,000 operations min.Electrical endurance (resistive load) *5 *6250 VDC, 25 A, 30,000 ops. min.Short-time carry current50 A (5 min), 40 A (10 min)Maximum interruption current *6100 A at 250 VDC (5 times)Overload interruption *650 A at 250 VDC (50 times min.)Ambient operating temperature−40 to 70°C (with no icing or condensation)Ambient operating humidity5% to 85% RHWeight (including accessories)Approx. 135 gG9EB-1DC Power Relays (25-A Models)G 9E B-1■Engineering Data●Maximum Switching Capacity●Electrical Endurance (Switching Performance)●Electrical Endurance (Interruption Performance)●Carry Current vs Energizing Time●Must-operate Voltage andMust-release Voltage Distributions●Time Characteristic Distributions●Vibration Malfunction●Vibration Resistances●●Shock ResistanceG9EB-1-B Switching/Current Conduction ModelsSwitching voltage (V)S w i t c h i n g c u r r e n t (A )Switching current (A)O p e r a t i o n s (x 10,000)Switching current (A)O p e r a t i o n s Carry current (A)E n e r g i z i n g t i m e (s )Percentage of rated voltage (%)N u m b e r o f R e l a y sTime (ms)N u m b e r o f c o n t a c t sFrequency (Hz)S i n g l e a m p l i t u d e (m m )Characteristics were measured after applying vibration at a frequency of 10 to 55 Hz (single amplitude of 0.75 mm) to the test piece (not energized) for 2 hours each in 3 directions. The percentage rate of change is the average value for all of the samples.R a t e o f c h a n g e (%)The value at which malfunction occurred was measured after applying shock to the test piece 3 times each in 6 directions along 3 axes.Characteristics were measured after applying a shock of 490 m /s to the test piece 3 times each in 6 directions along 3 axes. The percentage rate of change is the average value for all of the samples.R a t e o f c h a n g e (%)G9EB-1DC Power Relays (25-A Models)G 9 E B -1■Dimensions (Unit: mm)50●Screw Terminal TypeG9EB-1-B Terminal Arrangement/Internal Connections(TOP VIEW)Mounting Hole Dimensions(TOP VIEW)Dimension (mm)Tolerance (mm)10 or lower±0.310 to 50±0.550 or higher±1• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. M ake sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms.OMRON CorporationElectronic and Mechanical Components Company Contact: /ecb Cat. No. J187-E1-010812(0207)(O)Note: Do not use this document to operate the Unit.。

斯芬特10 DC电源说明书

斯芬特10 DC电源说明书

We bring quality to light.The SNT 10 DC Power Supply is a precision tool devel-oped to meet the needs of the automotive and vehicle industries in terms of accuracy, functionality, and user friendliness. It has been designed to be used in labora-tory environments in conjunction with photometric test equipment for high performance testing of vehicle and traffic lighting.Features include:50 V, 20 A (for U < 18 V) meeting the needs of today and tomorrow for testing and monitoring applications in the automotive and nonautomotive industries (other versions available) Unique adjustment accuracy 1 mV, 1 mA (or 0.1 mA) Low ripple & noise Fast up-and-down programming High accuracy current programming and read back Full protection from overcurrent, overvoltage,overtemperature Remote sense Electronic calibration CAN bus compatible RS 232 interface Standard 2-year warranty State-of-the-art choice for a reliable, high power DC supplySNT 10 DC Power Supply integration with AMS GoniophotometerTest table with recoCAN-L control unit and 10-channel multiplexer for integration ofup to three SNT 10 DC Power SuppliesSpecial featuresThe power supply has 5 channels allowing PC or manually controlled switchover between up to four light sources incorporated in a head or rear lamp assembly (fifth channel for connecting an integrating sphere)Operating LED equipped turn indicators in flashing mode (ECE R6 requirement) in conjunction with goniophotometer AMS controllerOperating HID equipped lamps without additional circuits2Test table with data interface, CAN-Bus, and multiplexer with 9 channels for threepower supplies, 9 x output/9 x senseLED high mounted stop lamp operated by SNT 10 HID (Xenon) Headlamp operated by SNT 1019” rack integrationInstrument Systems offers SNT 10 power supplies with higher adjustment resolution for current to be used in lower current applications (0.2 or 0.1 mA). See table of versions available.3Setting lamp parameters in LightCon SoftwareBurn-in graphic HID headlampSpecial features4 channels power + 4 channels sense wire connectedto lamp multiplexer at goniophotometer test tableAdditional channel for integrating sphere applications Compatible with AMS Goniophotometer systemPC control by LightCon SoftwareAutomatic burning-in of lamps with light control (luminous flux control, burn-in diagram for HID lamps)4Manual operationKey pad for manual control(direct input of voltage/current values)Sphere channel active Multiplexer channel activeConstant current or voltage operation 4 channels available for automatic selection (additional 5th channel for integrating sphere operation) Sense feedback controlVoltage/current adjustment knob Display of last calibration dateSetting nominal value for current Setting nominal value for voltage Setting maximum voltageFront panel SNT 10 DC Power Supply5Optronik LineDuring the developmental phase, our power supplies undergo a battery of environmental tests. The power supplies are designed with built-in margin so that they can meet their specifications over time, under all conditions, and also withstand peak stress. Wide design margins and stringent environmental tests guarantee reliable products.Support, services, and assistanceInstrument Systems aims to maximize the value you receive while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Optronik Line products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie our overall support policy: “Our Commitment” and “Your Advantage”.Our Commitment“Our commitment“ means your test and measurement equipment from the Optronik Line will meet its adver-tised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifica-tions and practical recommendations from experienced test engineers. When you use Optronik Line equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, upon request and at no extra cost.Your advantage“Your advantage” means that we offer a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibra-tion, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional services. Experienced engineers and technicians and our global sales and after-sales representative network worldwide can help you maximize your productivity, optimize the return on investment of your Optronik Line instruments and systems, and obtain dependable measurement accuracy for the life of those products.Instrument Systems’ Optronik Divisionis more than a manufacturer of photometer and gonio-photometer systems and accessories. We also offer a range of services to support customers who purchase Optronik Line products, as well as customers who outsource manufacturing, test, and calibration services. Customer service reflects a legacy of expertise in photometry technology and applications. No other manufacturer offers the knowledge base or the range of products developed by Instrument Systems, and no other goniophotometer series can be compared with the performance in both accuracy and speed of the Optronik Line AMS series.Get assistance with all your test and measurement needsat:****************Custom DevelopmentWe welcome inquiries for the design and manufacture of custom optical radiation measurement and test systems. Experienced research and development engineers work closely with our customers to provide the highest level of product development, applications, and technical support. Customer focus, quality, innovation and excellence drive our culture.You are welcome to visit our R&D and production plant in Berlin.6Technical specificationsLaboratory power supply with DC voltage, system compatible, switch-mode pre-adjustment, linear re-adjustment 16-bit D/A converter, 16-bit A/D converterPush-pull output stage, adjustment via sensor inputs (can be switched off)Automatic switch-selecting of current and voltage regulation, potential-free output, connections on the back of the instrumentDual output channels, option to connect a 4, 8, 9, or 10-channel lamp multiplexerAdditional 5th channel for integrated operation with integrating sphere for lamp flux measurementSense wiring for each channelOperation via front panel keyboard or serial interface RS232Large, graphic LC display with backlight illumination, microprocessor-controlled5-digit displayDisplay of mode of operation (constant current or constant voltage operation mode; remote PC aided or local, manual mode)Display of selected multiplexer channelCompatible to optoCAN Goniometer Interface BusPower factor correction7Instrument Systems GmbHKaiserin-Augusta-Allee 16-24 10553 Berlin, Germany Tel.: +49 30 34 99 41-0Fax: +49 30 34 55 054info _berlin @ /optronikInstrument Systems is continually working on the further development of its products.Technical changes, errors and misprints do not justify claims for damages.For all other purposes, our Terms and Conditions of Business shall be applicable.a。

Extech 382270高精度四通道DC电源用户指南说明书

Extech 382270高精度四通道DC电源用户指南说明书

User's GuideHigh Precision Quad OutputDC Power SupplyModel 382270IntroductionThank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit the Extech Instruments website () to check for the latest version of this User Guide.Safety InformationInternational Safety SymbolsThis symbol, adjacent to another symbol or terminal, indicates the user must refer to themanual for further information.This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltagesmay be presentDouble insulationSafety PrecautionsTo ensure safe operation of the equipment and eliminate the danger of serious injury due to short-circuit (arcing), the following safety precautions must be observed.∙Prior to connection of the equipment to the mains outlet, check that the available mains voltage corresponds to the voltage setting of the equipment.∙Connect the mains plug of the equipment only to a mains outlet with an earth ground connection.∙Do not place the equipment on damp or wet surfaces.∙Do not subject the equipment to direct sunlight or extreme temperatures.∙Do not subject the equipment to extreme humidity or dampness∙Replace a defective fuse only with a fuse of the original rating. Never short circuit the fuse or the fuse housing∙Do not exceed the maximum permissible input rating.∙Comply with the warning labels and other info on the equipment.∙Do not insert metal objects into the equipment by way of the ventilation slots∙Do not place water-filled containers on the equipment∙Do not operate the equipment near strong magnetic fields (motors, transformer etc.)∙Do not subject the equipment to shocks or strong vibrations∙Keep hot soldering irons away from the equipment∙Allow the equipment to stabilize at room temperature before use∙Do not modify the equipment in any way∙All service and repair must be performed by qualified service personal.Cleaning the meter housingPrior to cleaning the meter housing, disconnect the mains plug from the power outlet. Clean only with a damp, soft cloth and a commercially available mild household cleaner. Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment.Power Supply Description1. POWER2. Channel 4 Voltage adjustment3. Channel 4 overload status LED4. Channel 2 Current adjust knob5. Constant Current / Voltage statusLED for CH 46. Channel 2 Voltage adjust knob7. Voltage output display (CH 2/4)8. Current output display (CH 2/4)9. Current output display (CH 1/3)10. Voltage output display (CH 1/3)11. Channel 1 voltage output adjust knob12. Constant Voltage / Current statusLED for Channel 113. Current output adjust knob for Channel 114. Channel 4 overload status LED15. Voltage output adjust knob for Channel 316. Positive terminal CH 317. CH1 / CH 3 display select button18. Negative terminal CH 319. Positive terminal CH 120. SERIES / PARALLEL / INDEPENDENT tracking select button21. Negative terminal CH 122. GND terminal23. SERIES / PARALLEL / INDEPENDENT tracking select button24. Positive terminal CH 225. Output ON-OFF status LED26. Negative terminal CH 227. Output ON-OFF button28. Positive terminal CH 429. Negative terminal CH 430. CH2 / CH 4 display select buttonOperationIndependent Connections (Channels 1 and 2, adjustable outputs) Set the tracking switches (19) and (22) to the spring OUT position (INDEP). Set the Output On/Off switch (27) to the ON position.Constant Voltage (CV) Mode1. Rotate the CC knob (4) for CH 2 or (13) for CH 1 to maximum and then turn on the powersupply.2. Adjust CV knob (6) or (11) for the desired output.3. The color of the CV/CC status LED (5) or (12) will turn green.4. Current Limiting Note: For CV outputs in general, the CC adjustment should be set tomaximum, but, for this unit, the current limiting protection point can also be set arbitrarily. To do so:a) Turn on powerb) Rotate CC adjustment counter-clockwise to minimumc) Short the positive and negative terminalsd) Rotate the CC adjustment clockwise to the desired current-limiting protection point.Constant Current (CC) Mode1. Turn on the power supply.2. Rotate the CV knob (6) or (11) to maximum.3. Rotate the CC adjustment (4) or (13) to minimum4. Connect the required load.5. Rotate CC adjust knob clockwise to reach the desired current value.6. The color of the CV/CC status LED (5) or (12) will turn red.Series Connection (Channels 1 and 2, adjustable outputs)1. Set the tracking switch (20) to the spring OUT position. Press in tracking switch (23).2. In Series mode, the slave output will strictly track the master output voltage when the userturns the master voltage adjust knob (11). The output voltage in Series mode can be set up to double the maximum voltage available in Independent mode (voltage between terminals 19 &26).3. Ensure that both channels’ negative terminals are NOT connected to case ground. If they are,a short circuit will occur.4. When the two outputs are configured in Series, the voltage is controlled by the master outputknob (11), but the current adjustment for the two outputs is still independent. Therefore, ensure that the CC adjust knobs (4 and 13) are rotated fully clockwise to maximum for the Seriescircuit to work correctly.5. The user must physically short the negative terminal of the Master output (CH1-) with thepositive terminal of the Slaved output (CH2+).Parallel Connection (Channels 1 and 2 adjustable outputs)1. Press in both tracking switch (20) and tracking switch (23).2. In Parallel mode, the two outputs will always be the same for any setting of the master voltageknob (11). The slave CC indicator (5) will switch on.3. In Parallel mode the CC adjustment (4) for the slave is not active. The user must adjust the CCfor the master (CH1) output (13). The current available in parallel mode is up to twice theamount available in other modes.4. The user must short the two positive terminals. (CH1+ to CH2+)5. The user must also short the two negative terminals. (CH1- to CH2-)6. Use CH1 voltage control knob (11) to control the voltage level.7. Use CH1 CC knob (13) to control current.Specifications Range SpecificationsOutput1 (CH1) Output2(CH2)Output3(CH3)Output4(CH4)0~30V/0~5A 0~30V/0~5A 3~6.5V/3A 8~15V/1AElectrical SpecificationsInput voltage: 110~127VAC±10%; 220~240VAC±10% (switchable)Output voltage and current: See table aboveLine regulation:For Two adjustable outputs:CV: ≤ 1 x 10¯4 + 3mVCC ≤ 2 x 10¯3 + 3mATwo semi-adjustable outputs: ≤ 5mVLoad regulation:Two adjustable outputs:CV ≤5 x 10¯4 + 5mVCC ≤2 x 10¯3 + 5mACH3 ≤30mVCH4 ≤15mVRipple and noise:Two adjustable outputs:CV ≤ 1mV rmsCC ≤ 3mA rmsFixed output: ≤ 2mV rmsProtection: current-limitDisplay accuracy:Volt-indication: LED ± (0.5%rdg+2 digits)Amp-indication: LED ± (0.5%rdg+2 digits)General SpecificationsDisplay:Four 3-digit color-coded LED displays and four status LED lightsDimensions: 260 x 160 x 370mm (10.2 x 6.3 x 14.6") (W x H x D)Weight: 12 kg (26.4lbs)Copyright © 2013 FLIR Systems, Inc.All rights reserved including the right of reproduction in whole or in part in any formISO‐9001 Certified。

DC-DC 电源转换器说明书

DC-DC 电源转换器说明书

DC TO AC POWER INVERTERPWRNV1250W INSTRUCTION MANUALSAVE THIS MANUALYou will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.Basic Operation•Make sure that you choose the right operating voltage for both input and output of the inverter.•When unpacking, make sure that the inverter is in good condition. If any parts are missing or broken, please call AIMS Power, Inc. at the number found on the warranty card.•Place the power inverter on a flat surface. Make sure it has adequate ventilation and is not in direct sunlight. Fasten the inverter securely to the surface, using screws or some othermeans. If holes are to be drilled, follow safe, proper installation techniques.Before you connect the battery cables, make sure the power switch is in the off position. Connect Red (+) battery cable to Red (+) inverter terminal. Connect Black (-) battery cable to Black (-) inverter terminal. Connect Red (+) battery cable to Red (+) battery terminal. Connect Black (-) battery cable to Black (-) battery terminal. Alligator clamp cables may be used but only to connect to the battery.Do not use clamps on inverter terminals. Alligator clamps are not a permanent solution. You may see a spark during connection.•Connect the ground cable to an earth ground, such as a metal water pipe or to the vehicle ground when used in a vehicle if the inverter includes a ground port.•Turn the power switch to the on position, which is located on the front of the inverter. The green LED light will confirm that AC power is present.•Before plugging the equipment into the inverter, make sure the equipment AND the inverter are off. Turn inverter on first, then turn on the equipment.•The power inverter can be used either while the engine is running or off.Warnings•Unplug the inverter when it is not in use.•If the AC inverter makes a beeping sound, turn off the equipment, unplug the inverter and restart the vehicle’s engine. The beeping sound is simply the low-battery warning, which indicates that the voltage of your battery is getting low. If you do not re-start your engine and continue operating the inverter, the inverter will automatically shut off, leavingyour vehicle's battery at about 10. 5 VDC. This will allow you to start your engine and resumeoperation of the inverter. It also reduces the fear of being stranded with a dead battery(dependent on health of battery).•This device should only be serviced by a qualified technician. This item does not have any serviceable parts.•Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures during installation.•Do not operate the inverter if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgement or reflexes are impaired while taking drugs. Ifthere is any doubt, do not operate the inverter.•People with pacemakers should consult their physician(s) before using this product.Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker.•Keep children away. Children must never be allowed in the work area. Do not let them handle machines, tools, or extension cords.•Store idle equipment. When not in use, inverter must be stored in a dry location to prevent rust. Always lock up tools and the inverter and keep out of reach of children.•Size the inverter properly. Size the inverter for the surge rating of your equipment. The inverter’s continuous rating should be MORE than the surge rating of your equipment.Example: Power tool runs at 1500 watts but surges at 2500 watts. You should use an inverter >3000 watts.•Keep the inverter well-ventilated. Do not place any objects on top of or next to the inverter or allow anything to cover the cooling fans; doing so can cause the inverter to overheat,causing a potential fire hazard and/or damage to the inverter. Leave adequate ventilationspace underneath the inverter as well; thick carpets or rugs can obstruct air flow, causing the inverter to overheat.•Avoid unintentional starting. Be sure the switch is in the OFF position when not in use and before plugging in any appliance.Note: Performance of this unit may vary depending on the available battery power or appliance wattage.Warning: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by operator. Guard against electric shock. Do not open the metal case; risk of electric shock.Battery Use•To avoid over-discharging your vehicle battery, we recommend running your engine for 10-20 minutes to recharge the vehicle's battery if battery voltage drops <11V.•To properly size your battery, use the following formula: Volts * Amps = Watts or Watts/Volts = Amps. Example: 1000 watt inverter / 12 volts DC = 83.3 DC amps. In this example, you willneed 83.3 amps to power a 1000 watt load for 1 hour. If you need to power 1000 watts for 2hours you will need 83.3 * 2 = 166.66 DC amps available. A 100 amp hour battery will giveyou 100 amps / 166.66 = .6 hours so you will need two batteries if using 100 amp battery.This is if you fully deplete your batteries. We do NOT recommend fully depleting yourbatteries. This is just an example. Your power requirements may be different.•If you choose to use a female 12 Volt DC adapter for your inverter or to the inverter make sure wire size is correct.•IF YOU CONNECT THE WIRES TO THE INCORRECT TERMINALS, YOU WILL REVERSE THE POLARITY AND DAMAGE THE INVERTER.•REVERSED POLAR ITY WILL INSTANTLY VOID THE WARRANTY OF YOUR INVERTER, SO BE CAREFUL TO CONNECT YOUR INPUT WIRES PROPEPLY.•If you choose to operate a battery charger to replenish your battery’s voltage, be sure to check with charger manufacture before damaging the charger.•CONNECTING THE INVERTER’S DC INPUT TO A BATTERY CHARGER WILL VOID THE WARRANTY, AND MAY DAMAGE THE INVERTER.•Make sure that the battery voltage does not exceed 15 volts DC.•CONNECTING THE INVERTER TO A DC POWER SOURCE GREATER THAN 15 VDC WILL VOID THE WARRANTY, AND MAY DAMAGE THE INVERTER.CablesWe recommend that you refrain from using battery cables longer than 12 feet between the DC power source and the DC input of the inverter. Longer battery cables on the DC input will create a voltage drop which results in a reduction of efficiency and output. If you require more than 12 feet, use a bigger cable. We recommend using an extension cord between the AC output and AC appliance. You may use up to 100ft, high quality extension cord. A longer cord may result in reduced output. See Specifications chart for recommended battery cable size.Digital Bar DisplayThe digital bar display displays battery DC voltage and DC current. The current should always be in the green zone. The inverter will operate for several minutes when thecurrent is in the yellow zone. Operation in the red zone of the display will result in protective inverter shutdown. NOTE: The bar display will only monitor DC current and voltage not AC. If you need to measure AC output you will need to use a TRUE RMS MULTI METER.Remote On/Off SwitchSome models include a remote port. An AIMS remote on/off switch may be connected to the remote port. The optional remote on/off switch is a convenient option to turn the inverter on/off if the inverter is installed in a hard to reach area. Make sure the inverter is turned off before installing the remote switch. Simply plug the switch into the remote jack. There are several ways to mount the remote switch. Remote switch comes with 4 pre-drilled holes for mounting. Remote part # REMOTEHF.Measuring the AC VoltageThe output waveform of the inverter is a MODIFIED SINE WAVE. If you choose to measure the AC output voltage, you must use a TRUE RMS MULTI METER. Using any other type of voltage measuring device will result in an AC voltage reading of 10 to 30 volts lower than actual voltage. When using a true RMS multi meter, you will get an accurate reading.SAFETY PRECAUTIONS•Do not open the case of the inverter. The high voltage inside the unit is the same type of power as your electrical outlets at home.•Do not let the cord of the inverter, or any appliance cord get wet. If you are operating the inverter in a moving vehicle, we recommend that you secure the inverter to prevent it fromshifting around while the vehicle is moving.•Do not operate this inverter in or around water. Water can damage the inverter, and water damage is not covered under warranty. Also, do not operate the inverter with wet hands. The AC voltage of the unit makes it an electrical shock hazard if operated with wet hands.•Allow at least one inch of clearance around the Inverter for air flow. Ensure the ventilation openings on the rear and bottom of the unit are not obstructed.•Do not connect the inverter directly to another AC power source. Damage may result, and such damage will void the inverter warranty.•Know the wattage requirements of your appliance. Use only those appliances which are limited by the capacity of this unit.•Use common sense. This device produces power just like your wall outlets at home and should be treated seriously. Keep it away from children.•Reversed polarity of AC power outlet LINE /NEUTRAL will void the warranty.•If there is anything wrong with the inverter, disconnect all of the power and contact technical support.If the Inverter does not appear to be functioning properly, check the following possible causes:•Poor contact: Clean contact parts thoroughly.•If the low battery alarm sounds, this means the input voltage is too low and battery needs to be recharged.•If you are getting a low output voltage, try reducing the load to minimize watts. You may have overloaded the inverter. Reduce your load. Also, keep input voltage above 10.5 volts tomaintain a constant flow of power.•If you are not getting any power output, turn the power switch Off and On again, until the green power light comes on. Your devices may draw too much power to operate them. Theinverter may be in thermal shutdown. Let it cool down and make sure there is adequateventilation around the unit.•If the green light turns red one of the following has happened:A.input voltage is too lowB.input voltage is too highC.short circuitD.inverter is close to overload•Battery voltage is too low: Start the engine to recharge the battery. Replace or recharge battery if needed.•Shuts down on overload: Reduce the wattage of your load.•Thermal shutdown: Under heavy loads for extended period, the inverter will shut down to prevent damage from excess heat. Simply reduce your load and allow theInverter to cool down.•Low-battery shutdown: Recharge your battery and resume operation.Very little maintenance is required to keep your inverter operating properly. You should disconnect input power first and then clean the exterior of the unit periodically with a dry cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals.PLEASE READ THE FOLLOWING CAREFULLYNeither the manufacturer nor distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.WARRANTYAIMS Corp., Inc. dba AIMS Power Warranty Instructions:This product is designed using the most modern digital technology and under very strict quality control and testing guidelines. If, however, you feel this product is not performing as it should, please contact us:**************************(775)359-6703We will do our best to resolve your concerns. If the product needs repair or replacement, make sure to keep your receipt/invoice, as that will need to be sent back along with the package and RMA# prepaid to AIMS. You have a full 1 year warranty from date of purchase.This warranty is valid worldwide with the exception that freight and duty charges incurred outside the contiguous 48 United States will be prepaid by customer.Except as provided above, AIMS makes no warranty of any kind, express or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose. In no event shall AIMS be liable for indirect, special or consequential damages. This warranty only applies to AIMS Power branded products. All other name brand products are warranted by and according to their respective manufacturer. Please do not attempt to return non-AIMS Power branded products to AIMS Power.For additional products such as:-Modified sine wave inverters-Pure sine wave inverters-Low Frequency Inverters-Solar Charge Controllers-Micro Grid Tied Inverters-Inverter Chargers and Automatic transfer switches-Converters DC-DC-Custom cut cables-Batteries-Solar Panels & RacksPlease visit our web site: Tofindoutwheretobuyanyofourproducts,youmayalsoe-mail:************************ (775)359-6703.。

dc dc电源模块手册说明书

dc dc电源模块手册说明书

DC/DC电源模块手册电源解决专家PowerGood ,为电源模块而诞生的专家PowerGood 之工业应用电源模块,兼具应用范围广及规格多样化特色,可应用于各种工业化设备与系统之中,功率从1W-600W ,输入电压范围涵盖9-700Vin ,符合多国安规认证及EMC 认证,除了提供电源模块以外、更提供弹性的模组化电源(PSU),提供快速性客制化服务,紧贴着应用市场的脉动。

PowerGood 不断推陈出新,提供客户最适切的产品,成为工业设备应用领域的领航者。

航天应用电源模块 医疗应用电源模块医疗行业所需求的电源模块,倾向于小型化及专业可靠。

为了因应于医疗设备及加强型隔离系统之严苛应用,PowerGood 所提供应用于医疗用之电源模块,为BF 等级设计,并且增强绝缘4k Vac ,低泄漏电流 100uA 。

适合应用于医疗机械设备之中,包含呼吸器、分析仪等各类设备。

并且随着新型医疗设备不断涌现,PowerGood 将因应市场需求,设计出更多符合需求之医疗应用电源模块。

PowerGood 创立于1989年,至今已经三十余年,提供客户最优异的品质、专利的拓扑电路、稳定的交期、专业的服务,成为客户最强大的事业后盾及伙伴。

PowerGood 产品线完整,从AC/DC 到DC/DC 电源转换器,提供标准品来满足客户需求,并与终端使用者合作,研发客制化产品,解决客户痛点,成为客户最大的后盾。

工业应用电源模块轨道应用电源模块轨道交通建设已经进入快速发展阶段,并且在AC/DC 及DC/DC 电源模块中提出了更严苛设计及挑战需求,PowerGood 了解轨道应用之环境严峻,因此产品皆符合轨道产业需求的高可靠、高耐用的特性,可应用于轨道之中的牵引设备、监控设备、通讯设备、驾驶设备...等系统之中。

PowerGood 的轨道系列产品工作壳温宽、隔离耐压高,并通过EN50155认证及EN45545-2防火保护认证,是轨道交通应用的最佳解决方案。

Allen-Bradley 集成显示工业计算机 DC 电源使用技术说明书

Allen-Bradley 集成显示工业计算机 DC 电源使用技术说明书

Application TechniqueUsing DC Power with Industrial ComputersCatalog Numbers 6181F-12TSWE, 6181F-12TSXP , 6181P-12NSXP , 6181P-12TSXP , 6181F-15TSWE, 6181F-15TSXP , 6181P-15NSXP , 6181P-15TSXP , 6181F-17TSWE, 6181F-17TSXP , 6181P-17NSXP , 6181P-172TSXPAbout This Publication This publication covers instances where AC power is unavailable for anAllen-Bradley integrated-display industrial computer. The industrial computercatalog numbers discussed in this document are where the AC adapterbarrel-connector cable can be modified to work with a DC/DC converter.Use a DC/DC converter to:–provide a constant, conditioned 24V DC, thus protecting the computerfrom voltage fluctuations and surges.–buffer the rest of the system from any noise that the computer maygenerate on the DC power input.Rockwell Automation recommends an Allen-Bradley DC/DC converter,catalog number 1606-XLDC92D. Refer to publication 1606-IN019 for specificproduct data about this converter.Topic Page About This Publication 1Catalog Number Explanation 2Before You Begin 3Access and Remove the AC Adapter 3Modify the Barrel Connector Cable 5Additional Resources 72 Using DC Power with Industrial ComputersCatalog Number Explanation This table lists the integrated-display industrial computers covered in this publication.(1)6181F models have solid-state drives.Figure 1:Standard Computers, Front and Side ViewsCat. No.ModelDisplaySize (in.)Touch-screen PackageWindowsOperating System 6181P-12NSXP120012.1NoStandardXP6181P-12TSXPYes6181F-12TSXP (1)6181F-12TSWE (1)Embedded Standard 6181P-15NSXP150015.0NoStandardXP6181P-15TSXPYes6181F-15TSXP (1)6181F-15TSWE (1)Embedded Standard 6181P-17NSXP170017.0NoStandardXP6181P-17TSXPYes6181F-17TSXP (1)6181F-17TSWE (1)Embedded StandardItem Component1LCD panel2CompactFlash Type II card slot3Rear cover4Power adapter5Mounting slots (10)Publication 6000-AT001A-EN-P — March 2010Using DC Power with Industrial Computers 3Before You Begin You will need the following tools to complete the conversion instructions:•Phillips-head screwdriver•Wire stripping and cutting toolAccess and Remove the AC Adapter 1.See Figure 1 on page 2 to locate the AC adapter on the back panel of theindustrial computer.2.Locate the AC power input.3.Loosen the power cord retention clip and disconnect the power cord.4.Locate the DC barrel connector.5.Disconnect the DC barrel connector from the power input jack.DC BarrelConnectorAC Power CordPower CordRetention ClipPublication 6000-AT001A-EN-P — March 2010Publication 6000-AT001A-EN-P — March 20104 Using DC Power with Industrial Computers6.Remove the AC adapter from the back of the industrial computer.a.Remove the two screws on each side that secure the AC adapter to its mounting bracket.b.Cut the cable tie and remove the AC adapter from the mounting bracket.Using DC Power with Industrial Computers 5Modify the Barrel Connector Cable 1.Cut the barrel connector cable at the AC adapter end to remove thecable from the adapter.2.Strip the outer insulation on the cut end of the barrel connector cable toexpose the two wires.3.Strip the insulation on each wire (+DC and DC common) by at least7 mm (1/4 inch).Cut Cord HereRemoved AC Adapter+DC WireDC Common WirePublication 6000-AT001A-EN-P — March 2010Publication 6000-AT001A-EN-P — March 20106 Using DC Power with Industrial Computers4.Connect the +DC and DC common wires from the barrel connector cable to the corresponding output terminals of the DC/DC converter.5.Connect the 24V DC power-supply wires to the corresponding input terminals of the DC/DC converter.6.Reconnect the DC barrel connector to the power input jack on the back panel of the industrial computer.+DC Wire DC Common WireBlack Wire Red WirePublication 6000-AT001A-EN-P — March 2010Using DC Power with Industrial Computers 7Additional ResourcesThese documents contain additional information concerning integrated-display industrial computers.You can view or download publications at /literature . To order paper copies oftechnical documentation, contact your local Rockwell Automation distributoror sales representative.Resource DescriptionIntegrated Display Computers Installation Instructions, publication 6181-IN010Information on how to install and connect the computer.Integrated Display Industrial Computers User Manual, publication 6181P-UM002Information on how to install, connect, configure and troubleshoot the computer.DC/DC Converter Instruction Manual, publication 1606-IN019Information on DC/DC converter specifications and installation.Cloning Utility for Rockwell Automation Industrial Computers Technical Data, publication 6000-TD002Information on how to create and restore a back-up image of your computer’s hard disk drive.Diagnostic Utility Technical Data, publication 6000-TG001Information on how to diagnose hardware issues with the industrial computers.System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001Information, examples, and techniques designed to minimize system failures caused by electrical noise.EMC Noise Management DVD, publication GMC-SP004Publication 6000-AT001A-EN-P — March 2010Copyright © 2010 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At /support/, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit /support/.Installation AssistanceIf you experience an anomoly within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running.New Product Satisfaction ReturnRockwell Automation tests all of its products to ensure that they are fully operational when shipped from themanufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures.Documentation FeedbackYour comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at /literature/.United States or Canada 1.440.646.3434Outside United States or Canada Use the Worldwide Locator at /support/americas/phone_en.html , or contact your local Rockwell Automation representative.United StatesContact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process.Outside United StatesPlease contact your local Rockwell Automation representative for the return procedure.Allen-Bradley, Kinetix, Rockwell Automation, Rockwell Software, RSLogix 5000, and TechConnect are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.。

DC TO AC POWER INVERTER PWRINV800W使用说明书

DC TO AC POWER INVERTER PWRINV800W使用说明书

DC TO AC POWER INVERTERPWRINV800W INSTRUCTION MANUALSAVE THIS MANUALYou will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts list and diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep the manual and invoice in a safe and dry place for future reference.Basic Operation•Make sure that you choose the right operating voltage for both input and output of the inverter.•When unpacking, make sure that the inverter is in good condition. If any parts are missing or broken, please call AIMS Power, Inc. at the number found on the warranty card.•Place the power inverter on a flat surface. Make sure it has adequate ventilation and is not in direct sunlight. Fasten the inverter securely to the surface, using screws or some othermeans. If holes are to be drilled, follow safe, proper installation techniques.•Before you connect the battery cables, make sure the power switch is in the off position.Connect Red (+) battery cable to Red (+) inverter terminal. Connect Black (-) battery cable to Black (-) inverter terminal. Connect Red (+) battery cable to Red (+) battery terminal. Connect Black (-) battery cable to Black (-) battery terminal. Alligator clamp cables may be used but only to connect to the battery. Do not use clamps on inverter terminals. Alligator clamps are not a permanent solution. You may see a spark during connection.•Connect the ground cable to an earth ground, such as a metal water pipe or to the vehicle ground when used in a vehicle if the inverter includes a ground port.•Turn the power switch to the on position, which is located on the front of the inverter. The green LED light will confirm that AC power is present.•Before plugging the equipment into the inverter, make sure the equipment AND the inverter are off. Turn inverter on first, then turn on the equipment.•The power inverter can be used either while the engine is running or off.Warnings•Unplug the inverter when it is not in use.•If the AC inverter makes a beeping sound, turn off the equipment, unpl ug the inverter and restart the vehicle’s engine. The beeping sound is simply the low-battery warning, which indicates that the voltage of your battery is getting low. If you do not re-start your engine and continue operating the inverter, the inverter will automatically shut off, leavingyour vehicle's battery at about 10. 5 VDC. This will allow you to start your engine and resumeoperation of the inverter. It also reduces the fear of being stranded with a dead battery(dependent on health of battery).•This device should only be serviced by a qualified technician. This item does not have any serviceable parts.•Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures during installation.•Do not operate the inverter if under the influence of alcohol or drugs. Read warning labels on prescriptions to determine if your judgement or reflexes are impaired while taking drugs. Ifthere is any doubt, do not operate the inverter.•People with pacemakers should consult their physician(s) before using this product.Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker.•Keep children away. Children must never be allowed in the work area. Do not let them handle machines, tools, or extension cords.•Store idle equipment. When not in use, inverter must be stored in a dry location to prevent rust. Always lock up tools and the inverter and keep out of reach of children.•Size the inverter properly. Size the inverter for the surge rating of your equipment. The inverter’s continuous rating should be MORE than the surge rating of your equipment.Example: Power tool runs at 1500 watts but surges at 2500 watts. You should use an inverter >3000 watts.•Keep the inverter well-ventilated. Do not place any objects on top of or next to the inverter or allow anything to cover the cooling fans; doing so can cause the inverter to overheat,causing a potential fire hazard and/or damage to the inverter. Leave adequate ventilationspace underneath the inverter as well; thick carpets or rugs can obstruct air flow, causing the inverter to overheat.•Avoid unintentional starting. Be sure the switch is in the OFF position when not in use and before plugging in any appliance.Note: Performance of this unit may vary depending on the available battery power or appliance wattage.Warning: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by operator. Guard against electric shock. Do not open the metal case; risk of electric shock.Battery Use•To avoid over-discharging your vehicle battery, we recommend running your engine for 10-20 minutes to recharge the vehicle's battery if battery voltage drops <11V.•To properly size your battery, use the following formula: Volts * Amps = Watts or Watts/Volts = Amps. Example: 1000 watt inverter / 12 volts DC = 83.3 DC amps. In this example, you willneed 83.3 amps to power a 1000 watt load for 1 hour. If you need to power 1000 watts for 2hours you will need 83.3 * 2 = 166.66 DC amps available. A 100 amp hour battery will giveyou 100 amps / 166.66 = .6 hours so you will need two batteries if using 100 amp battery.This is if you fully deplete your batteries. We do NOT recommend fully depleting yourbatteries. This is just an example. Your power requirements may be different.•If you choose to use a female 12 Volt DC adapter for your inverter or to the inverter make sure wire size is correct.•IF YOU CONNECT THE WIRES TO THE INCORRECT TERMINALS, YOU WILL REVERSE THE POLARITY AND DAMAGE THE INVERTER.•REVERSED POLAR ITY WILL INSTANTLY VOID THE WARRANTY OF YOUR INVERTER, SO BE CAREFUL TO CONNECT YOUR INPUT WIRES PROPEPLY.•If you choose to operate a battery charger to replenish your battery’s voltage, be sure to check with charger manufacture before damaging the charger.•CONNECTING THE INVERTER’S DC INPUT TO A BATTERY CHARGER WILL VOID THE WARRANTY, AND MAY DAMAGE THE INVERTER.•Make sure that the battery voltage does not exceed 15 volts DC.•CONNECTING THE INVERTER TO A DC POWER SOURCE GREATER THAN 15 VDC WILL VOID THE WARRANTY, AND MAY DAMAGE THE INVERTER.CablesWe recommend that you refrain from using battery cables longer than 12 feet between the DC power source and the DC input of the inverter. Longer battery cables on the DC input will create a voltage drop which results in a reduction of efficiency and output. If you require more than 12 feet, use a bigger cable. We recommend using an extension cord between the AC output and AC appliance. You may use up to 100ft, high quality extension cord. A longer cord may result in reduced output. See Specifications chart for recommended battery cable size.Remote On/Off SwitchSome models include a remote port. An AIMS remote on/off switch may be connected to the remote port. The optional remote on/off switch is a convenient option to turn the inverter on/off if the inverter is installed in a hard to reach area.Make sure the inverter is turned off before installing the remote switch. Plug the switch into the remote jack and then turn the main switch to the OFF position for the remote to work properly.Measuring The AC VoltageThe output waveform of the inverter is a MODIFIED SINE WAVE. If you choose to measure the AC output voltage, you must use a TRUE RMS MULTI METER. Using any other type of voltage measuring device will result in an AC voltage reading of 10 to 30 volts lower than actual voltage. When using a true RMS multi meter, you will get an accurate reading.SAFETY PRECAUTIONS•Do not open the case of the inverter. The high voltage inside the unit is the same type of power as your electrical outlets at home.•Do not let the cord of the inverter, or any appliance cord get wet. If you are operating the inverter in a moving vehicle, we recommend that you secure the inverter to prevent it fromshifting around while the vehicle is moving.•Do not operate this inverter in or around water. Water can damage the inverter, and water damage is not covered under warranty. Also, do not operate the inverter with wet hands. The AC voltage of the unit makes it an electrical shock hazard if operated with wet hands.•Allow at least 12 inches of clearance around the Inverter for air flow. Ensure the ventilation openings on the rear and bottom of the unit are not obstructed.•Do not connect the inverter directly to another AC power source. Damage may result, and such damage will void the inverter warranty.•Know the wattage requirements of your appliance. Use only those appliances which are limited by the capacity of this unit.•Use common sense. This device produces power just like your wall outlets at home and should be treated seriously. Keep it away from children.•Reversed polarity of AC power outlet LINE /NEUTRAL will void the warranty.•If there is anything wrong with the inverter, disconnect all of the power and contact technical support.If the Inverter does not appear to be functioning properly, check the following possible causes:•Poor contact: Clean contact parts thoroughly.•If the low battery alarm sounds, this means the input voltage is too low and battery needs to be recharged.•If you are getting a low output voltage, try reducing the load to minimize watts. You may have overloaded the inverter. Reduce your load. Also, keep input voltage above 10.5 volts tomaintain a constant flow of power.•If you are not getting any power output, turn the power switch Off and On again, until the green power light comes on. Your devices may draw too much power to operate them. Theinverter may be in thermal shutdown. Let it cool down and make sure there is adequateventilation around the unit.•If the green light turns red one of the following has happened:A.input voltage is too lowB.input voltage is too highC.short circuitD.inverter is close to overload•Battery voltage is too low: Start the engine to recharge the battery. Replace or recharge battery if needed.•Shuts down on overload: Reduce the wattage of your load.•Thermal shutdown: Under heavy loads for extended period, the inverter will shut down to prevent damage from excess heat. Simply reduce your load and allow theInverter to cool down.•Low-battery shutdown: Recharge your battery and resume operation.Very little maintenance is required to keep your inverter operating properly. You should disconnect input power first and then clean the exterior of the unit periodically with a dry cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals.PLEASE READ THE FOLLOWING CAREFULLYNeither the manufacturer nor distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.WARRANTYAIMS Corp., Inc. dba AIMS Power Warranty Instructions:This product is designed using the most modern digital technology and under very strict quality control and testing guidelines. If, however, you feel this product is not performing as it should, please contact us:**************************(775)359-6703We will do our best to resolve your concerns. If the product needs repair or replacement, make sure to keep your receipt/invoice, as that will need to be sent back along with the package and RMA# prepaid to AIMS. You have a full 1 year warranty from date of purchase.This warranty is valid worldwide with the exception that freight and duty charges incurred outside the contiguous 48 United States will be prepaid by customer.Except as provided above, AIMS makes no warranty of any kind, express or implied, including without limitation the implied warranties of merchantability and fitness for a particular purpose. In no event shall AIMS be liable for indirect, special or consequential damages. This warranty only applies to AIMS Power branded products. All other name brand products are warranted by and according to their respective manufacturer. Please do not attempt to return non-AIMS Power branded products to AIMS Power.For additional products such as:-Modified sine wave inverters-Pure sine wave inverters-Low Frequency Inverters-Solar Charge Controllers-Micro Grid Tied Inverters-Inverter Chargers and Automatic transfer switches-Converters DC-DC-Custom cut cables-Batteries-Solar Panels & RacksPlease visit our web site: Tofindoutwheretobuyanyofourproducts,youmayalsoe-mail:************************ (775)359-6703.。

DC POWER操作指导书

DC POWER操作指导书

制作部門
研发部
對象
品质部检验人员
注意事項﹕
1.DC輸出線最好接到背板的輸出端﹐接上回收線有利于儀器檢測輸出端電 電 壓起到調節輸出精確度。
2.DC輸出正負要分清﹐與量測物的正負相互對應﹐不能接反。 3.DC輸出端不能長時間處于短路狀態﹐限流點過高會容易燒壞儀器。
故障排除﹕
1.電壓限流點都設定后接上DC輸出線后無電壓﹐檢查儀器輸出端是否有
9.工作電壓輸入插座
4
5
日期 本頁版本 更新內容
2013/3/4
A/0
制作者 曹海祥
確認
審核
王新江
谢沉香
深圳市微腾创科技有限公司
文件編號 頁次
WTC-WI-T-019A/0 2 of 4
2
4 56
7
13
9
10
11 圖一
7 6 8 9 圖二
儀器名稱 說明
SHENZHEN VATYN INDUSTRY CO.,LTD.
接觸不良或脫落現象。
2.DC輸出線與量測物連接后﹐接觸良好﹐發現量測物不工作﹐檢查限流
點是否有過低﹐測物是否有短路現象。
3.儀器不開機﹐檢查工作電壓保險絲是否有燒壞現象。
4.工作輸入電壓一定要與安全工作電壓選擇檔選擇選擇的電壓
1
相同。
2
保養﹑清潔﹕
3
1.定期清潔內部﹑散熱窗口灰塵。(用風槍)
2.保持外表清潔。
8.工作電源開關
9.DC輸出負極
3
10.DC輸出地
12
11.DC輸出正極
12.限流保護指示燈
8
13.DC輸出正常指示鄧
图二说明(背面面板)
1.正極輸出回收接線柱

PowerDC分析基础_100621

PowerDC分析基础_100621
33
用what-if分析来改善设计
Original VRM pins After turn the VRM 180 degree around (Done inside PowerDC GUI)
34
5. Package中的直流分析
35
GND平面上的IR Drop分布
Hotspots
36
发现大的过孔电流
R=V/I。
σ为材料的电导率,铜的电导率为 5.8 x 107 S/m
12
电流密度

自由电荷在导体中流动形成传导电流,其密度为 导电媒质中的恒流电场的基本方程为


电源/地平面上的电流密度是矢量分布,而平面上的标 量电流是没有物理意义的
13
PowerDC的主要功能



9
PowerDC的算法及理论基础
PowerDC基于电磁场理论求出电源/地平面上的电压
分布、电流密度的矢量分布,过孔电流和电阻。
全新的FEM仿真引擎在仿真精度和效率上有了很大的
提升。其精细的三角形网格剖分比其他工具采用的矩 形网格在计算结果和显示精度上要先进很多,另外特 有的快速算法使工具即使在仿真大型PCB时也仅需数 分钟的时间。
27
电源走线宽度计算器
28
4. PCB中的直流分析
29
电源平面
30
结果
9
31
过孔电流
Hotspot identifier
大量电流通过黄色过孔,贯穿2个 电源平面的重叠部分。
32
发现第11层上的高电流密度
高电流密度
显示电流密度在 5mA/mil^2 及以上的部分;小于该指标的以灰色来显示。

Model 1550 DC电源供应器使用和安全操作说明书

Model 1550 DC电源供应器使用和安全操作说明书

Instruction ManualModel1550DC Power Supply with USB Charger Output1-30V,0-3.3AKeep this manual in a safe place for quick reference at all times.This manual contains important safety and operation instructions for correct use of the power supply.Read through the manual and pay special attention to the markings and labels of this unit and equipment to be connected.Pay special attention to these notices used in this manual:WARNING:Failure to observe this warning may cause injury to persons and damage to power supplyor connected equipment.CAUTION:Failure to observe this warning may result in damage to equipmentand Improper functioning of the power supply.WARNING:1.Do not use this power supply near water.2.Do not operate or touch this power supply with wet hands.3.Do not open the casing of the power supply when it is connected to ac mains.4.Refer all servicing to qualified service personnel only.5.Before replacing the AC fuse at AC socket,find out and clear up the cause first.6.Replace the AC fuse with the same type and rating as the original fuse.CAUTION:e a grounded3pin AC source.2.This unit is for indoor use only.3.Do not operate or place this unit in a humid,dusty,in direct sunlight location or near any heatsource.4.Before plugging into local AC mains,check with the rating label at the back of the unit.5.Do not block any ventilation openings of the unit.6.This unit must be used within the specified rating;regular excessive continuous loading maycause damage to the power supply.7.The gauge size of input power cable must be at least0.75mm2and the total length of powercable must not exceed3m.OPERA TION ENVIRONMENTAL CONDITION∙10-80%R.H.∙Maximum relative humidity80%for temperature up to31°C decreasing linearly to50% relative humidity at40°C.∙Altitude up to2000m∙Installation category:CAT2∙Pollution degree:2∙Mains supply voltage fluctuation up to±10%of the normal voltageINTRODUCTIONSing the1550switching mode power supplyThe unit is a Micro-controller based DC power supply with a total supply capability of 100W.By using a digital+/-keypad operation control,you can set the output voltage and current easily.It is a clean supply with quiet operation making it ideal for laboratory, work shop or educational applications where work bench space is limited.The1550has a USB charger output,constant current operation,tracking OVP,floating ground design,small footprint,output on/off push button and a small formfactor.ing the USB power outputThe USB output is made to the USB power standard of5VDC and0.4A.You can power up or charge your portables such as an I-Pod,MP3Player or CellPhone*which have USB power connectors for getting dc power from a PC(PersonalComputer).*-REMARKS:NOT ALL THE CELL PHONE CAN BE CHARGED BY THE USB.SOME NEW MODELS REQUIRE HIGHER VOLTAGE THAN THE5V USB.PLEASEREFFERENCE THE MANUFACTURES DOCUMENTATION OF THE DEVICE TO BECONNECTED FOR COMPATABILITY ISSUES.1.Power Switch:Turns the power supply on–off,when it is on the front display lights up2.AC Input Socket with Fuse3.Concealed Fuse box(please open the cover to get to the fuse)4.V:Output Voltage Setting keypad5.A:Output Current Setting keypad6.“+”ascend Setting keypad.Press to ascend the numerical values7.“-”descend Setting keypad.Press to descend the numerical values8.Output On/Off push button.B Output SocketStandard USB DC power5V,400mATo charge or to power portables and cell phones10.Output Terminal Positive(+)Red color11.GND Terminal(:)Green colorChassis ground terminal,normally this is to be short to(+)or(-)as required by user12.Output Terminal Negative(-)Black color13.LCD Display panel showing:3digit voltage,current meter,(CV)constant voltage mode,(CC)constant currentmode,Output Terminal on/off stateO P E R A T I O N SGround ConnectionDepending on the application,the power supply output terminals can be grounded in any one of the following grounding conditions:Negative ground–black(-)negative terminal is shorted with green GND terminal.Positive ground–red(+)positive terminal is shorted with green GND terminal.Floating ground–green terminal is not shorted with any of the output terminals.Remarks:When operating this power supply as a floating ground,high impedance leakage can exist between the power supply circuitry and the chassis ground.Basic Mode of OperationThis power supply is designed to operate as a constant voltage source or as a constant current source.Automatic crossover to either mode of operation occurs when the load condition changes as following:Voltage value setting:at first,you must press the(4)keypad,then you can adjust the voltage value to your desired value by(6)and(7)keypad.Current value setting:at first,you must press the(5)keypad,then you can adjust the current value to your desired value by(6)and(7)keypad.Constant Voltage(CV),Automatic crossover&Constant Current(CC)The power supply functions as a constant voltage source(CV)as long as the load current is less than the preset current limiting value.When the load current is equal to or greater than the preset current limiting value,the power supply will automatically cross over to the constant current mode,voltage will drop,(CC)will show on the LCD display panel and it will operate as a constant current source.When the load current drops below the preset current limiting value,the supply returns to constant voltage(CV)mode.Presetting Current Limiting Value(CC)Switch on the power supply,adjust the output voltage to about3V,turn off the output terminal with push button(8),icon becomes.Short the black and red output terminals and turn on the output terminal by(8),icon becomes ,adjust the current limiting value to your desired value say x Amp by(6)and(7) keypad.Turn off the output terminal and take out the shorting connection.The current limiting of power supply has been preset to x Amp for the whole range of output voltage.Connection and Operation Procedure1.After checking with the rating label plug in to AC mains.2.Switch on the power supply and the LCD display should be on at the same time.3.The(CV)icon should be shown on the display.4.Set the current value to maximum by press(6)keypad if you do not require lower Currentlimiting value,otherwise do the preset the(CC)limiting procedure.5.Set your desired output voltage and then turn off the output terminal by push button(8).6.Connect to your load positive to positive and negative to negative.7.Turn on the output terminal again and check if display shows(CV).8.If display shows(CC),either your preset current limiting value is too low or your load requiresmore voltage and current.You need to re-access the voltage and current requirement of your load and increase the voltage or current accordingly until(CV)appears.Tracking Output Over Voltage Protection(OVP)This is to protect the connected load in the event that the output voltage control circuit mal-functions,the maximum output voltage will not exceed40%of the adjusted voltage value at the time of the operation.Over Temperature ProtectionWhen the temperature inside the power supply becomes higher than a pre-determined value,the output voltage and current of the power supply will automatically decrease to zero to prevent damage to power supply.When the temperature inside the power supply returns to about65°C then the power supply will automatically return to operation again.SpecificationsAC I nput100–120Vac, 60Hz*Full Load Input Current at120Vac 1.8A(+10%)MAIN OUTPUT:Output Voltage Adjustable Range 1.0–36VDCOutput Current Adjustable Range0–3AVoltage RegulationLoad from10%to100%+50mVLine from min to max+20mVRipple(rms)+5mVNoise(Peak to Peak)+50mVCurrent RegulationLoad from10%to100%+20mALine from min to max+20mASwitching Operation Frequency80KHz to120KHzEfficiency at Max Power83%(+10%)Voltmeter and Ammeter Display3DigitVoltmeter Accuracy+1%+5rdg.Ammeter Accuracy+1%+5rdg.USB OUTPUT:Output Voltage5V(+10%)Output Current400mA(+10%)Load Voltage Regulation80mV(+10%)Ripple&Noise(no load rms)8mV(+10%)LCD Indication CC,CV,Amp,Volt,Output ON-OFFProtection Short Circuit,Overload,Over Temperature,Tracking OVP Cooling System Natural ConvectionDimensions(WxHxD) 2.8x6.0x9.8(70x150x250mm)Weight 4.4lbs.(2Kgs)Note: *For 220V input, order model number 1550-220VLimited One-Year WarrantyB&K Precision warrants to the original purchaser that its products and the component parts thereof,will be free from defects in workmanship and materials for a period of one year from date of purchase from an authorized B&K Precision distributor.B&K Precision will,without charge,repair or replace,at its option,defective product or component parts.Returned product must be accompanied by proof of the purchase date in the form of a sales receipt.To obtain warranty coverage in the U.S.A.,this product must be registered by completing the warranty registration form on within fifteen(15)days of purchase.Exclusions:This warranty does not apply in the event of misuse or abuse of the productor as a result of unauthorized alterations or repairs.The warranty is void if the serial number is altered,defaced or removed.B&K Precision shall not be liable for any consequential damages,including without limitation damages resulting from loss of use.Some states do not allow limitations of incidental or consequential damages.So the above limitation or exclusion may not apply to you.This warranty gives you specific rights and you may have other rights,which vary from state-to-state.SERVICE INFORMATIONWarranty Service:Please go to our website,&click on the service/repair button to obtain an RMA#.Return the product in the original packaging with proof of purchase to the address below.Clearly state in writing the performance problem and return any leads,probes, connectors and accessories that you are using with the device.Non-Warranty Service:Please go to our website,&click on theservice/repair button to obtain an RMA#.Return the product in the original packaging to the address below.Clearly state in writing the performance problem and return any leads,probes, connectors and accessories that you are using with the device.Customers not on open account must include payment in the form of a money order or credit card.For the most current repair charges please visit and click on“service/repair”.Return all merchandise to B&K Precision Corp.with pre-paid shipping.The flat-rate repair charge for Non-Warranty Service does not include return shipping.Return shipping to locations in North American is included for Warranty Service.For overnight shipments and non-North American shipping fees please contact B&K Precision Corp.B&K Precision Corp.22820Savi Ranch ParkwayYorba Linda,CA92887714-921-9095Include with the returned instrument your complete return shipping address,contact name,phone number and description of problem.22820Savi Ranch Parkway Yorba Linda,CA 92887USA TEL:714-921-9095FAX: Printed in Hong Kong2008B&K Precision Corp.。

ZUMA - High Current DC Power Supply 用户手册说明书

ZUMA - High Current DC Power Supply 用户手册说明书

USER MANUALTO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.The lightning flash, with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure, that may be of sufficient magnitude to constitute a risk of electric shock.The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instruction in the literature accompanying the appliance.Important Safety InformationBefore using Zuma, please be sure to read all operating instructions carefully.• Read, follow, and keep these instructions.• Heed all warnings.• Do not expose this unit to liquids or moisture.• Clean only with a dry cloth.• Do not block any ventilation openings.• Do not install near any heat sources.• Do not defeat the safety purpose of the polarized or grounding-type plug.• Protect the power cord and pedal cables from being walked on or pinched.• Use only attachments and/or accessories specified by Strymon.• Use only mounting brackets as specified by Strymon.• Unplug during lighting storms or when unused for long periods of time.• Do not attempt to service this unit yourself, as opening or removing cover may expose you to dangerous voltage or other hazards. Refer all servicing to qualified Strymon service personnel.• Servicing is required when the unit has been damaged in any way, such as a power cord or plug is damaged, liquid has been spilled or objects have fallen into the unit, the unit has been exposed to rain or moisture, does not operate normally, or has been dropped.• Never pu sh any object into the slots or openings on your unit enclosure.• When connected to a power outlet, power is always flowing into your unit. To totally disconnect power, unplug the power cord.Connect the included IEC cable to Zumaand plug the other end into an AC poweroutlet. Zuma operates worldwide (120V,240V, 100V) with the appropriate IECcable.Zuma will powermost effects pedalson the market,including allStrymon pedals.Check with eachpedal manufacturerfor recommendedvoltage, polarity, andrequired current.For pedals thathave unique powerrequirements(more than 500mAof current, othervoltages such as24V), you can find configuration details here: / support/zuma 24V DC OUT:Connect a StrymonOjai (sold separately)to the 24V DC OUT jackand gain additionaloutputs for yourpedals.LED INDICATOR:Each output featuresan LED indicator.LED illuminatesgreen when a pedalcable is pluggedin. LED will turnoff if cable isunplugged, or thecurrent draw on theoutput exceeds themaximum amountavailable.Getting StartedConnect Your PedalsA total of nine high or low-current pedals can be connected to Zuma. Additional outputs can be added by connecting a Strymon Ojai (sold separately) to the 24V OUT jack.PEDAL OUTPUTS: Connect up to nine effects pedals with the included5.5mm x 2.1mm pedal cables. Each output is dual-isolated for noise-free operation.9V OUTPUTS:Seven outputs provide9V DC, center negative polarity, each with 500mA of available current.ADJUSTABLE OUTPUTS:Two outputs provide selectable 9V, 12V, or 18V DC, each with center negative polarity. Each output provides 500mA of available current at 9V, 375mA at 12V, and 250mA at 18V.Zuma is ExpandableYou can link as many as 6 Ojai units to your Zuma, powering up to39 effects pedals. While it’s unlikely that anyone would go to such extremes, we wanted to ensure Zuma delivers maximum flexibility and expandability. A much more likely scenario would be to link 1 or 2 Ojai units to your Zuma, powering a combination of 20 high and low current draw pedals. To connect Ojai units to your Zuma:1. Power your first Zuma with the included IEC cable.2. Connect one end of Ojai’s included EIAJ-05 poweradapter cable to the 24V OUT on your Zuma.3. Connect the other end of the EIAJ-05 power adaptercable to the 24V IN of your Ojai.4. Link additional Ojai units by connecting one end ofthe EIAJ-05 cable to the 24V THRU to the 24V IN onthe next Ojai in the chain.Is your pedalboard growing? Gain more outputs by linking Strymon Ojai units (sold separately) to the 24V OUT jack. Zuma is part of a truly expandable, modular power distribution system that can grow with your pedalboard.Learn more about linking Zuma power supplies together:/support/zuma• Zuma dimensions 6.8” x 3.3” x 1.8” (173mm x 84mm x 46mm)• Zuma weight 1.25 lbs. (680g)• Zuma Input 100-240V AC 50/60Hz • Zuma 9V DC Outputs Seven (5) 9V DC, 500mA, center-negative • Zuma Adjustable Outputs Two (2) Selectable 9V DC (500mA), 12V DC (375mA), or 18V DC (250mA) center-negative• Zuma high-current DC power supply • IEC cable (region-specific)• Nine (9) 2.1mm x 5.5mm pedal cables (24” long, straight to right angle barrel connectors)• 9 high-current, fully isolated outputs • 9 outputs offer 9V DC option • 500mA per 9V DC output powers nearly any pedal •2 selectable outputs offer 9V, 12V, or 18V DC options • 12V option provides 375mA, 18V provides 250mA • 9 pedal cables included (5.5mm x 2.1mm barrel connectors, center negative, right angle to straight cables)• Detachable IEC power cable included • 24V OUT jack allows connection to additional outputs via Strymon Ojai (sold separately)• Nine individual custom transformers (one per channel) deliver clean, consistent power • Worldwide power compatibility ensures no-hassle international touring • Energy efficient, compact design• Lightweight and rugged anodized midnight blue aluminum chassis • Fits under most pedalboards • PedalTrain mounting bracket available (sold separately) • Designed and built in the USA Features Specifications What’s In the Box?Questions?INS & OUTS TECHNOLOGY CONSTRUCTIONStrymon Non-Transferrable Limited WarrantyExclusions This warranty covers defects in manufacturing discovered while using this product as recommended by Strymon. This warranty does not cover loss or theft, nor does the coverage extend to damage caused by misuse, abuse, unauthorized modification, improper storage, lightning, or natural disasters.Limits of Liability In the case of malfunction, the purchaser’s sole recourse shall be repair or replacement, as described in the preceding paragraphs. Strymon will not be held liable to any party for damages that result from the failure of this product. Damages excluded include, but are not limited to, the following: lost profits, lost savings, damage to other equipment, and incidental or consequential damages arising from the use, or inability to use this product. In no event will Strymon be liable for more than the amount of the purchase price, not to exceed the current retail price of the product. Strymon disclaims any other warranties, express or implied. By using the product, the user accepts all terms herein.How to Obtain Service Under this Warranty For North American customers: Contact Strymon through our website at /support for Return Authorization and information. Proof of original ownership may be required in the form of a purchase receipt.For International Customers: Contact the Strymon dealer from which the product was purchased from in order to arrange warranty repair service.Strymon ® is a division of Damage Control ®, LLC.Warranty Strymon warrants the product to be free from defects in material and workmanship for a period of five (5) years from the original date of purchase. If the product fails within the warranty period, Strymon will repair or, at our discretion, replace the product at no cost to the original purchaser.。

DC电源模块(13.5Vdc)安装说明:Eaton Corporation(俄麦)COOPER PO

DC电源模块(13.5Vdc)安装说明:Eaton Corporation(俄麦)COOPER PO

DC power module (13.5 Vdc) installation instructionsDISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITYThe information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s (“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recom-mendations and descriptions contained herein. The information contained in this manual is subject to change without notice.ii DC power module (13.5) Vdc installation instructions MN225010EN January 2015 ContentsSAFETY INFORMATIONSafety Information (iv)PRODUCT INFORMATIONIntroduction (1)Acceptance and Initial Inspection (1)Handling and Storage (1)Standards (1)PARTS SUPPLIEDKit Part Contents (2)INSTALLATION PROCEDURESInstallation Procedure (2)DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 iiiEaton’s Cooper Power™ series products meet or exceed all applicable industry standards relating to product safety. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service.We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our “Safety For Life” mission.iv DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 1 DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 Accessory slot in lower portion of mainAuxiliary accessory extrusion attached to backThe extrusion may be installed in anyone of three locations on the back of a control.2DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 3. Slide the aluminum card-support bar into the groves inthe back of the accessories slot and secure with thesupplied 0.25” screw. See Figures 4 and 5. This step is not required if an accessory is already installed into part of the slot as shown in Figure 2.4. Slide the DC power module circuit board into thegroves in the accessory slot. Figure 6 shows installation of the module into an accessories slot in a single-phase control.5. Fully seat the DC power module into the slot andsecure with two of the screws retained in step 2. SeeFigure 7. Note that the module can be installed into anyavailable slot as convenient.Figure 4. Installing aluminum card-support bar intoaccessories slot.Figure 5. Aluminum card-support bar secured with 0.25"screw.Figure 6. Inserting the DC power module into theaccessories slot in a single-phase control.Figure 7. Securing the DC power module with screwsinto the accessories slot of the main control panel.3 DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 6. If required, install the accessories slot blank cover plateand secure with two of the screws retained in step 2.See Figure 8.7. Install the power cord between the CL-7 control and theDC power module as shown in Figure 9.8. Wrap the power cord with cable ties to eliminateexcess length and snip off the ends of the ties. See Figure 10.side of a CL-7 control. Power connections can be madeto the orange plug; the top plug is the negative terminaland the bottom plug is the positive terminal.10. Install the CL-7 control back into the control box byreversing the process in step 1.Figure 8. Installing the accessories slot blank coverplate.Figure 9. Installing the power cord.Figure 11. DC power module fully installed.4DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 This page is intentionally left blank.5 DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 This page is intentionally left blank.6DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 This page is intentionally left blank.7 DC power module (13.5 Vdc) installation instructions MN225010EN January 2015 Eaton and Cooper Power are valuable trademarks of Eaton, in the U.S. and other countries. Y ou are not permitted to use these trademarks without the prior written consent of Eaton. Eaton 1000 Eaton Boulevard Cleveland, OH 44122United States Eaton's Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188United States © 2015 Eaton All Rights Reserved Printed in USA Publication No. MN225010EN / January 2015For Eaton's Cooper Power series Quik-Drive tap-changer product information call 1-877-277-4636 or visit: .。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

9
10
11
儀器名稱 說明
DC電源(DC Power Supply Sps--606) 說明事項/故障排除/保養
操作指 導 書
WORK INSTRUCTION SHEET
制作部門
研发部
對象
品质部检验人员
注意事項﹕
1.DC輸出線最好接到背板的輸出端﹐接上回收線有利于儀器檢測輸出端電 電 壓起到調節輸出精確度。
4.DC負極輸出接線柱
5.負極輸出回收接線柱
1
6.散熱排風口
2
7.輸出過壓保護可調電阻
3
8.工作電壓230V/115V選擇開關
9.工作電壓輸入插座
4
5
日期 本頁版本 更新內容
2013/3/4
A/0
制作者 曹海祥
確認
審核
王新江
谢沉香
深圳市微腾创科技有限公司
文件編號 頁次
WTC-WI-T-019A/0 2 of 4
2
4 56
7
13
9
10
11 圖一
7 6 8 9 圖二
儀器名稱 說明
SHENZHEN VATYN INDUSTRY CO.,LTD.
操作指 導 書
WORK INSTRUCTION SHEET
DC電源(DC Power Supply Sps--606)
制作部門
研发部
具體操作與實例
對象
品质部检验人员
一例﹕設定一組+12V調節率為1%﹐最大負載1.5A.
3.儀器不開機﹐檢查工作電壓保險絲是否有燒壞現象。
4.工作輸入電壓一定要與安全工作電壓選擇檔選擇選擇的電壓
1
相同。
2
保養﹑清潔﹕
3
1.定期清潔內部﹑散熱窗口灰塵。(用風槍)
2.保持外表清潔。
4
5
文件編號 頁次
WTC-WI-T4 of 4
7 6 8 9
日期 本頁版本 更新內容
2013/3/4
A/0
制作者 曹海祥
儀器名稱 說明
深圳市微腾创科技有限公司
SHENZHEN VATYN INDUSTRY CO.,LTD.
操作指 導 書
WORK INSTRUCTION SHEET
DC電源(DC Power Supply Sps--606)
制作部門
研发部
前面面板/背面面板介紹
對象
品质部检验人员
圖一說明(前面面板)
1.電流顯示屏
1
壓為47.52V--48.48V.
2.旋轉電流粗調旋鈕直到參照點接近最大值。
文件編號 頁次
4
5
6
WTC-WI-T-019A/0 3 of 4
2
7 3 12 8
日期 本頁版本 更新內容
2013/3/4
A/0
制作者 曹海祥
確認
審核
王新江
谢沉香
深圳市微腾创科技有限公司 SHENZHEN VATYN INDUSTRY CO.,LTD.
2.DC輸出正負要分清﹐與量測物的正負相互對應﹐不能接反。 3.DC輸出端不能長時間處于短路狀態﹐限流點過高會容易燒壞儀器。
故障排除﹕
1.電壓限流點都設定后接上DC輸出線后無電壓﹐檢查儀器輸出端是否有
接觸不良或脫落現象。

2.DC輸出線與量測物連接后﹐接觸良好﹐發現量測物不工作﹐檢查限流
點是否有過低﹐測物是否有短路現象。
2.電壓顯示屏
3.輸出限流微調旋
1
4.輸出限流粗調旋
5.高/低檔限流按鈕開關
6.輸出電壓微調
7.輸出電壓粗調
8.工作電源開關
9.DC輸出負極
3
10.DC輸出地
12
11.DC輸出正極
12.限流保護指示燈
8
13.DC輸出正常指示鄧
图二说明(背面面板)
1.正極輸出回收接線柱
2.DC正極輸出接線柱
3.輸出地
確認 王新江
審核 谢沉香
U1CU24154 CU4163
操作步驟﹕ 1.旋轉電壓粗調旋鈕直到電壓顯示屏接近12V﹐然后再調節微調旋鈕直 到電壓為11.88V--12.12V范圍內。 2.旋轉電流粗調旋鈕直到參照點越過中點偏右(最大限流點為3A,限流 檔位調到低檔位)。
二例﹕設定一組+48V,調節率為1%﹐最大負載為4A.
操作步驟﹕
1.旋轉電壓粗調旋鈕電壓顯示屏接近48V﹐然后再調節微調旋鈕直到電
相关文档