阿尔卡特朗讯常见告警解释

合集下载

贝尔bsc-mfs-bts alarm共56条(基本囊括阿尔卡特设备的所有告警---网优必备)

贝尔bsc-mfs-bts alarm共56条(基本囊括阿尔卡特设备的所有告警---网优必备)

珠海网管监控告警告警级别原级别CODE 告警模块次要告警Minor[35,0]BSC重大告警Critical[35,2]BSC不确定Indeterminate[35,3]BSC主要告警Major[36,3]BSC主要告警Major[36,4]BSC不确定Indeterminate[39,1]BSC不确定Indeterminate[39,3]BSC不确定Indeterminate[39,5]BSC不确定Indeterminate[39,7]BSC不确定Indeterminate[39,18]BSC不确定Indeterminate[42,1]BSC不确定Indeterminate[42,2]BSC不确定Indeterminate[42,3]BSC不确定Indeterminate[42,7]BSC 珠海网管监控告警主要告警Major[42,9]BSC严重告警Critical[42,12]BSC不确定Indeterminate[42,13]BSC不确定Indeterminate[42,14]BSC 珠海网管监控告警主要告警Major[43,0]CELL次要告警Minor[43,1]CELL次要告警Minor[43,2]CELL 珠海网管监控告警主要告警Major[43,3]CELL不确定Indeterminate[43,4]CELL不确定Indeterminate[43,5]CELL次要告警Minor[43,248]CELL次要告警Minor[44,0]BTS_O &M次要告警Minor[44,1]BTS_O &M次要告警Minor[44,2]BTS_O &M次要告警Minor[44,3]BTS_O &M次要告警Minor[44,5]BTS_O &M次要告警Minor[44,6]BTS_O &M次要告警Minor[44,7]BTS_O &M次要告警Minor[44,10]BTS_O &M次要告警Minor[44,11]BTS_O &M次要告警Minor[44,12]BTS_O &M次要告警Minor[45,0]BSC 不确定Indeterminate[45,1]BSC 不确定Indeterminate[45,2]BSC 不确定Indeterminate[45,3]BSC 重大告警Critical[45,4]BSC 轻微告警Warning[46,0]BSC 轻微告警Warning[46,1]BSC 轻微告警Warning[46,4]BSC 不确定Indeterminate[47,2]BSC 不确定Indeterminate[47,3]BSC不确定Indeterminate[47,4]BSC不确定Indeterminate[47,5]BSC不确定Indeterminate[47,6]BSC不确定Indeterminate[47,7]BSC主要告警Major[47,9]BSC不确定Indeterminate[47,11]BSC不确定Indeterminate[47,12]BSC不确定Indeterminate[47,13]BSC不确定Indeterminate[47,15]BSC不确定Indeterminate[47,16]BSC主要告警Critical[47,17]BSC次要告警Minor[47,18]BSC不确定Indeterminate[47,19]BSC次要告警Minor[47,20]BSC次要告警Minor[47,21]BSC主要告警Major[47,22]BSC不确定Indeterminate[47,23]BSC不确定Indeterminate[47,24]BSC主要告警Major[49,0]性能主要告警Major[49,1]性能主要告警Major[49,2]性能主要告警Major[49,3]性能次要告警Minor[54,1]BTS主要告警Major[66,21]TC主要告警Major[66,22]TC 珠海网管监控告警主要告警Major[66,50]TC次要告警Minor[66,66]TC 珠海网管监控告警主要告警Major[66,81]TC主要告警Major[66,86]TC 珠海网管监控告警主要告警Major[66,99]TC次要告警Minor[66,100]TC次要告警Minor[66,102]TC次要告警Minor[66,176]TC次要告警Minor[66,208]TC不确定Indeterminate[66,210]TC次要告警Minor[66,211]TC主要告警Major[67,22]TC次要告警Minor[67,72]TC次要告警Minor[67,122]TC 珠海网管监控告警主要告警Major[67,128]TC主要告警Major[67,130]TC 珠海网管监控告警主要告警Major[67,131]TC主要告警Critical[70,219]BSC主要告警Major[73,22]TC主要告警Major[73,128]TC主要告警Major[73,130]TC不确定Indeterminate[73,148]TC次要告警Minor[73,202]TC次要告警Minor[73,203]TC次要告警Minor[73,212]TC主要告警Major[73,213]TC不确定Indeterminate[73,216]TC次要告警Minor[73,241]TC次要告警Minor[73,246]TC次要告警Minor[73,247]TC次要告警Minor[74,20]BSC主要告警Major[74,22]BSC主要告警Major[74,23]BSC次要告警Minor[74,122]BSC 珠海网管监控告警主要告警Major[74,124]BSC主要告警Major[74,128]BSC主要告警Major[74,130]BSC主要告警Major[74,139]BSC主要告警Major[74,141]BSC主要告警Major[74,142]BSC不确定Indeterminate[74,148]BSC主要告警Major[74,159]BSC次要告警Minor[74,202]BSC次要告警Minor[74,241]BSC次要告警Minor[74,245]BSC次要告警Minor[74,246]BSC次要告警Minor[74,247]BSC次要告警Minor[75,20]TC主要告警Major[75,22]TC主要告警Major[75,112]TC次要告警Minor[75,122]TC 珠海网管监控告警主要告警Major[75,124]TC主要告警Major[75,128]TC主要告警Major[75,130]TC 珠海网管监控告警主要告警Major[75,136]TC主要告警Major[75,139]TC主要告警Major[75,141]TC主要告警Major[75,142]TC不确定Indeterminate[75,148]TC主要告警Major[75,159]TC次要告警Minor[75,202]TC不确定Indeterminate[75,208]TC主要告警Major[75,209]TC不确定Indeterminate[75,210]TC次要告警Minor[75,211]TC不确定Indeterminate[75,216]TC 珠海网管监控告警主要告警Major[75,221]TC次要告警Minor[75,222]TC 珠海网管监控告警主要告警Major[75,223]TC主要告警Major[75,224]TC主要告警Major[75,225]TC次要告警Minor[75,226]TC次要告警Minor[75,227]TC次要告警Minor[75,228]TC主要告警Major[75,231]TC次要告警Minor[75,232]TC主要告警Major[75,233]TC主要告警Major[75,234]TC主要告警Major[75,235]TC次要告警Minor[75,236]TC次要告警Minor[75,237]TC次要告警Minor[75,238]TC次要告警Minor[75,241]TC次要告警Minor[75,245]TC次要告警Minor[75,246]TC次要告警Minor[75,247]TC不确定Indeterminate[96,0]BSC不确定Indeterminate[96,1]BSC主要告警Major[96,2]BSC 珠海网管监控告警主要告警Major[96,3]BSC不确定Indeterminate[97,0]BSC不确定Indeterminate[97,1]BSC主要告警Major[97,2]BSC主要告警Major[97,3]BSC不确定Indeterminate[97,4]BSC不确定Indeterminate[97,5]BSC次要告警Minor[97,6]BSC次要告警Minor[97,8]BSC主要告警Major[97,10]BSC重大告警Critical[97,11]BSC主要告警Major[97,12]BSC次要告警Minor[97,13]BSC重大告警Critical[97,14]BSC 珠海网管监控告警主要告警Major[97,15]BSC次要告警Minor[97,16]BSC不确定Indeterminate[97,17]BSC次要告警Minor[97,20]BSC不确定Indeterminate[97,21]BSC不确定Indeterminate[97,30]BSC不确定Indeterminate[97,31]BSC不确定Indeterminate[97,32]BSC不确定Indeterminate[97,33]BSC不确定Indeterminate[97,34]BSC不确定Indeterminate[97,35]BSC不确定Indeterminate[97,36]BSC不确定Indeterminate[97,38]BSC不确定Indeterminate[97,39]BSC不确定Indeterminate[97,50]BSC不确定Indeterminate[97,51]BSC不确定Indeterminate[98,0]BSC主要告警Major[98,3]BSC次要告警Minor[98,6]BSC次要告警Minor[98,8]BSC主要告警Major[98,10]BSC重大告警Critical[98,11]BSC主要告警Major[98,12]BSC次要告警Minor[98,13]BSC重大告警Critical[98,14]BSC主要告警Major[98,15]BSC次要告警Minor[98,16]BSC次要告警Minor[98,18]BSC不确定Indeterminate[99,0]BSC主要告警Major[99,3]BSC次要告警Minor[99,6]BSC次要告警Minor[99,8]BSC主要告警Major[99,10]BSC重大告警Critical[99,11]BSC主要告警Major[99,12]BSC次要告警Minor[99,13]BSC重大告警Critical[99,14]BSC主要告警Major[99,15]BSC次要告警Minor[99,16]BSC不确定Indeterminate[99,17]BSC 珠海网管监控告警主要告警Major[99,18]BSC 珠海网管监控告警主要告警Major[99,19]BSC不确定Indeterminate[100,1]BSC 珠海网管监控告警主要告警Major[100,4]BSC次要告警Minor[100,6]BSC次要告警Minor[100,8]BSC 珠海网管监控告警主要告警Major[100,17]BSC次要告警Minor[100,18]BSC主要告警Major[100,50]BSC主要告警Major[100,51]BSC 珠海网管监控告警主要告警Major[101,0]BSC 珠海网管监控告警次要告警Minor[101,1]BSC 珠海网管监控告警主要告警Major[101,2]BSC 珠海网管监控告警主要告警Major[101,4]BSC 珠海网管监控告警次要告警Minor[101,5]BSC次要告警Minor[101,6]BSC次要告警Minor[101,7]BSC不确定Indeterminate[101,8]BSC次要告警minor1E+06MFS严重告警critical1E+06MFS严重告警critical1E+06MFS严重告警critical1E+06MFS主要告警major1E+06MFS次要告警minor1E+06MFS严重告警critical1E+06MFS次要告警minor1E+06MFS主要告警major1E+06MFS严重告警critical1E+06MFS珠海网管监控告警主要告警major1E+06MFS严重告警critical1E+06MFS次要告警minor1E+06MFS严重告警critical1E+06MFS主要告警major1E+06MFS主要告警major 1016433MFS次要告警minor 1016451MFS严重告警critical1E+06MFS严重告警critical1E+06MFS严重告警critical1E+06MFS严重告警critical1E+06MFS 珠海网管监控告警主要告警major1E+06MFS主要告警major1E+06MFS次要告警minor1E+06MFS珠海网管监控告警主要告警major1E+06MFS珠海网管监控告警主要告警major1E+06MFS次要告警minor1E+06MFS严重告警critical1E+06MFS主要告警major1E+06MFS主要告警major1E+06MFS主要告警major1E+06MFS主要告警major1E+06MFS主要告警major1E+06MFS主要告警major1E+06MFS主要告警major1E+06MFS轻微告警WARNING1E+06MFS次要告警MINOR1E+06MFS 珠海网管监控告警主要告警MAJOR1E+06MFS次要告警MINOR1E+06MFS严重告警CRITICAL1E+06MFS次要告警MINOR1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS主要告警MAJOR1E+06MFS主要告警MAJOR1E+06MFS 珠海网管监控告警主要告警MAJOR1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS 珠海网管监控告警主要告警MAJOR1E+06MFS严重告警CRITICAL1E+06MFS 珠海网管监控告警主要告警MAJOR1E+06MFS珠海网管监控告警主要告警MAJOR1E+06MFS主要告警MAJOR1E+06MFS主要告警MAJOR1E+06MFS次要告警MINOR1E+06MFS主要告警MAJOR1E+06MFS次要告警MINOR1E+06MFS次要告警MINOR1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS 珠海网管监控告警主要告警MAJOR1E+06MFS次要告警MINOR1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS珠海网管监控告警主要告警MAJOR1E+06MFS次要告警MINOR1E+06MFS严重告警CRITICAL1E+06MFS严重告警CRITICAL1E+06MFS次要告警MINOR1E+06MFS次要告警MINOR1E+06MFS 珠海网管监控告警主要告警Major [1,6] BTS 珠海网管监控告警主要告警Major[1,12]BTS 珠海网管监控告警主要告警Major [1,31]BTS次要告警Minor[1,234] BTS次要告警Minor[1,237] BTS主要告警Major [1,240] BTS轻微告警Warning[1,247] BTS轻微告警Warning[1,248] BTS轻微告警Warning[2,1] BTS轻微告警Warning[2,247] BTS轻微告警Warning[2,248] BTS轻微告警Warning[3,0] BTS轻微告警Warning[3,1] BTS轻微告警Warning[3,2] BTS主要告警Major [3,11]BTS轻微告警Warning[3,13]BTS主要告警Major [3,14]BTS主要告警Major[3,246] BTS次要告警Minor[4,5] BTS主要告警Major [4,6] BTS次要告警Minor[4,14]BTS主要告警Major [4,15]BTS次要告警Minor[4,16]BTS主要告警Major [4,17]BTS主要告警Major [4,240] BTS主要告警Major [4,246] BTS 珠海网管监控告警主要告警Major[5,0] BTS次要告警Minor[5,1] BTS主要告警Major [5,2] BTS次要告警Minor[5,3] BTS次要告警Minor[5,4] BTS次要告警Minor[5,5] BTS 珠海网管监控告警严重告警Critical [5,11]BTS主要告警Major [5,12]BTS 珠海网管监控告警严重告警Critical [5,13]BTS 珠海网管监控告警严重告警Critical [5,20]BTS 珠海网管监控告警主要告警Major [5,23]BTS主要告警Major [5,24]BTS主要告警Major[5,31]BTS 珠海网管监控告警主要告警Major [5,32]BTS主要告警Major [5,237] BTS 珠海网管监控告警主要告警Major [5,239] BTS 珠海网管监控告警主要告警Major[6,34]BTS主要告警Major [6,50]BTS主要告警Major [6,240] BTS主要告警Major [7,242] BTS轻微告警Warning[8,3] BTS轻微告警Warning[8,4] BTS轻微告警Warning[8,5] BTS轻微告警Warning[8,8] BTS主要告警Major [8,26]BTS主要告警Major[8,30]BTS主要告警Major [8,31]BTS轻微告警Warning[8,32]BTS轻微告警Warning[8,247] BTS轻微告警Warning[8,248] BTS不确定Critical [9,1] BTS不确定Critical [9,2] BTS次要告警Minor[9,3] BTS次要告警Minor[9,4] BTS不确定Critical [9,5] BTS主要告警Major [9,6] BTS主要告警Major [9,7] BTS次要告警Minor[9,8] BTS次要告警Minor[9,9] BTS次要告警Minor[9,10]BTS主要告警Major [9,11]BTS 次要告警Minor[9,12]BTS 次要告警Minor[9,13]BTS 次要告警Minor[9,14]BTS 次要告警Minor[9,15]BTS 不确定Critical [9,16]BTS 次要告警Minor[9,17]BTS 次要告警Minor[9,18]BTS 次要告警Minor[9,19]BTS 次要告警Minor[9,20]BTS 次要告警Minor[9,21]BTS 次要告警Minor[9,22]BTS 次要告警Minor[9,23]BTS 次要告警Minor[9,24]BTS 次要告警Minor[9,25]BTS 次要告警Minor[9,26]BTS 次要告警Minor[9,27]BTS 次要告警Minor[9,28]BTS 次要告警Minor[9,29]BTS 次要告警Minor[9,30]BTS 次要告警Minor[9,31]BTS 次要告警Minor[9,32]BTS 次要告警Minor[9,33]BTS 次要告警Minor[9,34]BTS 次要告警Minor[9,35]BTS 次要告警Minor[9,36]BTS 次要告警Minor[9,37]BTS 次要告警Minor[9,38]BTS 次要告警Minor[9,39]BTS 次要告警Minor[9,40]BTS 次要告警Minor[9,41]BTS 次要告警Minor[9,42]BTS 次要告警Minor[9,43]BTS 次要告警Minor[9,44]BTS 次要告警Minor[9,45]BTS 次要告警Minor[9,46]BTS 次要告警Minor[9,47]BTS次要告警Minor[9,48]BTS次要告警Minor[9,49]BTS次要告警Minor[9,50]BTS次要告警Minor[9,51]BTS次要告警Minor[9,52]BTS次要告警Minor[9,53]BTS次要告警Minor[9,54]BTS次要告警Minor[9,55]BTS次要告警Minor[9,56]BTS轻微告警Warning[10,1]BTS主要告警Major [10,3]BTS 珠海网管监控告警主要告警Major [10,10] BTS次要告警Minor[10,11] BTS 珠海网管监控告警主要告警Major [10,12] BTS次要告警Minor[10,21] BTS次要告警Minor[10,22] BTS主要告警Major [10,51] BTS次要告警Minor[10,234]BTS次要告警Minor[10,237]BTS 珠海网管监控告警主要告警Major[10,239]BTS轻微告警Warning[10,248]BTS轻微告警Warning[10,248]BTS 珠海网管监控告警主要告警Major[11,22] BTS 珠海网管监控告警主要告警Major[11,50] BTS次要告警Minor[11,66] BTS 珠海网管监控告警主要告警Major[11,81] BTS 珠海网管监控告警主要告警Major[11,86] BTS 珠海网管监控告警主要告警Major[11,99] BTS 珠海网管监控告警主要告警Major[11,100]BTS 珠海网管监控告警主要告警Major[11,102]BTS次要告警Minor[11,176]BTS告警信息[35,0] LNK-REP[35,2] RTE-REP[35,3] INC-REP[36,3] RAI[36,4] AIS[39,1] OSN-NON-RECOVERABLE [39,3] OSN-PROCEDURAL [39,5] USR-NONRECOVERABLE [39,7] HWR-NONRECOVERABLE[39,18] SANITY-TIMER[42,1] NACK-MSC[42,2] OVERLOAD-MSC[42,3] START-RESET[42,7] NO-RESET-CIC[42,9] OVERLOAD-BSC[42,12] TEL-PAIR-LOST [42,13] BSC-TRAFFIC-REPORT[42,14] GPRS-RESET[43,0] LOSS-OF-BCCH[43,1] LOSS-OF-SDCCH [43,2] LOSS-OF-TCH[43,3] LOSS-OF-ALL-CHAN [43,4] CELL-TRAFFIC-REPORT [43,5] OVERLOAD-BTS[43,248] CONFIGURED POOLS NOT FULLY USABLE[44,0] AUDIT-FAIL[44,1] PROTOCOL-FAIL[44,2] RECONFIG-FAIL[44,3] DOWNLOAD-FAIL[44,5] SW-ACTIVATE-FAIL[44,6] CONFIG-DATA-FAIL[44,7] OMU-SELFTEST-FAIL[44,10] ABORT-FAIL[44,11] PRELOAD-FAIL[44,12] BTS-HW-CONFIG-FAIL[45,0] CH-UNBLOCK-FAIL[45,1] CH-BLOCK-FAIL[45,2] BSC-CIC-UNKNOWN[45,3] MSC-CIC-UNKNOWN[45,4] END-OF-REP-OF-UNBLOCK-PROC [46,0] SYNC CORRUPTED[46,1] UNSYNC-OTHER-CORR[46,4] SECFILE-ROLLBACK[47,2] AUTO-BSC-RESET[47,3] AUTO-BSC-RESTART[47,4] BSC-SYNC-REQ[47,5] BTS-SYNC-REQ[47,6] AUDIT-COMPLETED[47,7] BSC-HW-RESYNC[47,9] CBC-CONNECTION-FAILURE [47,11] ABIS-TS-ALLOC-FAILED[47,12] INSUFFICIENT-TCU-RES[47,13] TRE-SECTOR-MISMATCH[47,15] SWRPL-IN-PROGRESS[47,16] MAX-TRE-EXCEEDED[47,17] MLPPP-FAILURE[47,18] MLPPP-PARTIAL-FAILURE [47,19] DLS-RESTORATION[47,20] NTP-DRIFT-TIME-ALERT[47,21] NTP-TIME-SERVER-UNREACHABLE [47,22] NTP-DRIFT-TIME-EXCEEDED [47,23] MAX-HDLC-EXCEEDED[47,24] MUX-SECTOR-NOT-COMP-2ABIS [49,0] LOW-TRAF-SDCCH[49,1] CH-INCONSIST-SUSP[49,2] TCH-BLOCK-SUSPECT[49,3] TCH-OCCUP-SHORT[54,1] EXTRA TS NOT FULLY USABLE [66,21] LOOP-TO-ITF[66,22] LOOP-TO-EQUIP[66,50] TWO-MB-MISSING[66,66] AIS-2-MB[66,81] FRAME-ALIGNMENT[66,86] CRC-MFRAME-ALGN[66,99] BER-10E-3[66,100] BER-10E-4[66,102] BER-10E-6[66,176] FAR-END-ALARM [66,208] I1I2-AIS[66,210] TRANS-FLT[66,211] LOSS-OF-CLK-2M [67,22] LOOP-TO-EQUIP[67,72] AIS-16-KB[67,122] TRAU-SYNCHRO[67,128] EQUIPMENT-FAULT [67,130] MEMORY-FAULT[67,131] INT-BUS-FAULT [70,219] SW-FAULT[73,22] LOOP-TO-EQUIP[73,128] EQUIPMENT-FAULT [73,130] MEMORY-FAULT[73,148] RESET[73,202] NO-Q1-CONN[73,203] LOSS-OF-ACT[73,212] LOSS-OF-CLK-8M [73,213] LOSS-OF-CLK-BOTH-8M [73,216] RESTART[73,241] SET-PROD-FAIL [73,246] DOWNLOAD-FAIL [73,247] ACCESS-FAIL[74,20] BLOCKED-FROM-USE [74,22] LOOP-TO-EQUIP[74,23] TESTMODE[74,122] SYNCHRO-AL[74,124] SYNC-AL-CLOCKR [74,128] EQUIPMENT-FAULT[74,130] MEMORY-FAULT [74,139] MISSING-UNIT [74,141] FORCED-CNTRL-ON [74,142] INSTALLATION [74,148] RESET[74,159] DIAG-TESTS[74,202] NO-Q1-CONN[74,241] SET-PROD-FAIL [74,245] LOCAL-REINIT-REQ [74,246] DOWNLOAD-FAIL [74,247] ACCESS-FAIL [75,20] BLOCKED-FROM-USE [75,22] LOOP-TO-EQUIP [75,112] FAN-ALARM[75,122] SYNCHRO-AL[75,124] SYNCHRO-AL-CLOCKR [75,128] EQUIPMENT-FAULT [75,130] MEMORY-FAULT [75,136] FIRST-DSP-FAIL [75,139] MISSING-UNIT [75,141] FORCED-CNTRL-ON [75,142] INSTALLATION [75,148] RESET[75,159] DIAG-TESTS[75,202] NO-Q1-CONN[75,208] TRIB-TRANS-FLT[75,209] INT-BUS-FLT-G25[75,210] ATER-TRANS-FLT[75,211] LOSS-OF-CLK-2M [75,216] RESTART[75,221] TRIB-TWO-MB-MISSING [75,222] TRIB-AIS-2MB[75,223] TRIB-FRAME-ALIGNMENT [75,224] TRIB-CRC-MFRAME-ALGN [75,225] TRIB-BER-10E-3 [75,226] TRIB-BER-10E-4 [75,227] TRIB-BER-10E-6 [75,228] TRIB-FAR-END-ALARM [75,231] ATER-TWO-MB-MISSING [75,232] ATER-AIS-2MB[75,233] ATER-FRAME-ALIGNMENT[75,234] ATER-CRC-MFRAME-ALGN [75,235] ATER-BER-10E-3 [75,236] ATER-BER-10E-4 [75,237] ATER-BER-10E-6 [75,238] ATER-FAR-END-ALARM [75,241] SET-PROD-FAIL[75,245] LOCAL-REINIT-REQ[75,246] DOWNLOAD-FAIL[75,247] ACCESS-FAIL[96,0] RESET[96,1] RESTART[96,2] MULTIPLE-RESET[96,3] ACCESS-FAIL[97,0] RESET[97,1] TAKEOVER[97,2] RLC-OV[97,3] ACCESS-FAIL[97,4] APPLICATION-FATAL-TERMINATION [97,5] SYSTEM-FATAL-TERMINATION [97,6] UNPLUGGED[97,8] FW-UPGRADE[97,10] FATAL-HW-FAILURE[97,11] TEMPERATURE-CRITICAL[97,12] TEMPERATURE-MAJOR[97,13] TEMPERATURE-MINOR[97,14] VOLTAGE-FATAL[97,15] VOLTAGE-MAJOR[97,16] VOLTAGE-MINOR[97,17] ETHERNET-LINK-FAILURE[97,20] CONFIGURATION-FAILURE[97,21] TAKEOVER-REFUSED[97,30] N7-DEVICE[97,31] HDLC-HANDLER[97,32] Q1-HANDLER[97,33] RW-HANDLER[97,34] TDM-FAILURE[97,35] E1-FRAMER[97,36] TP-MAIN-SW-ERROR[97,37] TP-MAIN-FILE-ERROR [97,38] TP-MAIN-ACCESS-PB [97,39] SS7-SW-ERROR[97,50] NE1OE-FAILURE[97,51] E1-SL-FAILURE[98,0] RESET[98,3] ACCESS-FAIL[98,6] UNPLUGGED[98,8] FW-UPGRADE[98,10] FATAL-HW-FAILURE[98,11] TEMPERATURE-CRITICAL [98,12] TEMPERATURE-MAJOR [98,13] TEMPERATURE-MINOR [98,14] VOLTAGE-FATAL[98,15] VOLTAGE-MAJOR[98,16] VOLTAGE-MINOR[98,18] IP-ROUTER-LINK-FAIL [99,0] RESET[99,3] ACCESS-FAIL[99,6] UNPLUGGED[99,8] FW-UPGRADE[99,10] FATAL-HW-FAILURE[99,11] TEMPERATURE-CRITICAL [99,12] TEMPERATURE-MAJOR [99,13] TEMPERATURE-MINOR [99,14] VOLTAGE-FATAL[99,15] VOLTAGE-MAJOR[99,16] VOLTAGE-MINOR[99,17] ETHERNET-LINK-FAILURE [99,18] SHELF-MANAGER-ACCESS-PB [99,19] FAN-FAILURE[100,0] RESET[100,1] MUX-TAKEOVER[100,4] ACCESS-FAIL[100,6] UNPLUGGED[100,8] FW-UPGRADE[100,17] PEM-FAILURE[100,18] 48V-REDUNDANCY-LOSS[100,50] NE1OE-FAILURE[100,51] E1-SL-FAILURE[101,0] LIS[101,1] AIS[101,2] LFA[101,4] BER-10E-3[101,5] RAI[101,6] BER-10E-4[101,7] BER-10E-6[101,8] FRAME-SLIPGPU board has lost ethernet linkLoss of contact with GPU16E1 serial link failure on GPU boardNE1OE supervision error on GPU boardGPU NE1OE contact errorNE1OE software(SW) and NE1OE (FW) not compa Voltage out of rangeTemperature reaches minor threshold Temperature reaches major thresholdTemperature reaches critical thresholdDSP offlinePLX9054 auto-test errorTime base clock offlineOn free run modeNGISL3 auto-test errorIPMC problem on GPU boardEthernet Link auto-test errorGPU Autotest errorBSC GPRS service lostBSS GSL is brokenBSS BVCSig is brokenLapDLink is brokenAt least, one sleeping Cell is detected int Cell auto-restartNo response from networkLoss of Packet ServiceBSS BVCSig of this GPU is brokenBSS BVCSig of this GPU is broken - Not secuSGSN in user modeNo reply from SGSNNSEI mismatch: SGSN sends a wrong NSEI at rNSVCI mismatch: SGSN sends a wrong NSVCI at PVC DLCI is inactivePVC DLCI is unknown from the networkA-GPS server not reachableTemperature warningTemperature alarmTemperature major alarmFailure of a Chassis fanFailure of all chassis fansFailure of a chassis power unitFailure of all power units of a chassis Card voltage out of rangeICMB Access ProblemStation unreachable through LSNLoss of contactSoftware configuration errorFatal software errorLocal Disk I/O errorFatal Hardware ErrorPMC Access FailureCard failureFatal Ethernet switch errorRouter communication failureNon Fatal Router Path failureFatal Router Path failureA-GPS router not reachable through LSN 1A-GPS router not reachable through LSN 2LOS: PCM link between transceiver and recei LFA: Loss of Frame AlignmentAIS: only bits '1' into two successive fram CH0-EERH : excessive error rate BER 10-3 RAI: remote alarm indication signalling an DFM: Driver failure monitor or short circui CRC4-BERH: excessive error rate BER 10-4 CRC4-BERL : excessive error rate BER 10-6 GPU extracted when not lockedMUX supervision errorMUX contact errorPEM in LIU shelf not operationalLIU board not operational16E1 serial link failure on MUX boardLoss of 48V redundancy for a PEM LIUNE1OE software(SW) and NE1OE (FW) not compa [1,6] MCL-FATAL-AL[1,12] CLOCK-FAULT[1,31] MCL-XCLK[1,234] IOM-DISCONNECTION[1,237] HW-DEGRADED[1,240] MISSING-ENTRY-IN-CPF[1,247] RESET[1,248] RESTART[2,1] LOSS OF TWIN CONFIGURATION[2,247] RESET[2,248] RESTART[3,0] UNKNOWN-UNIT[3,1] UNKNOWN-CMD-MSG[3,2] UNKNOWN-ALARM[3,11] SW-PROBLEM[3,13] TELECOM-CONFIG-FAIL[3,14] WRONG-CONFIGURATION[3,246] CONFIG-FAIL[4,5] FN-AL[4,6] INTERNAL-FN[4,14] FCLK-AL[4,15] INT-FCLK-AL[4,16] OBCLK-AL[4,17] INTERNAL-OBCLK[4,240] MISSING-ENTRY-IN-CPF[4,246] CONFIG-FAIL[5,0] POWER-SUPPLY[5,1] FAN-ALARM[5,2] FAN-ALARM-U[5,3] FAN-ALARM-T[5,4] BTS-TEMP-ALARM[5,5] CPLG-ALARM[5,11] POWER-SUPPLY-U[5,12] POWER-SUPPLY-NU[5,13] CONTROL-UNIT-AL[5,20] MAINS-AL[5,23] POWER-SHUTDOWN[5,24] SUBRACK-POWER[5,31] TEMPERATURE-WARNING[5,32] FATAL TEMPERATURE[5,237] HW-DEGRADED[5,239] HW-FAILURE[6,34] ANTENNA-VSWR[6,50] DATA-INCONSIS-AL[6,240] MISSING-ENTRY-IN-CPF[7,242] INCONSIST-actHW-logConfig [8,3] RESYNCH[8,4] IGNORE EQUIPMENT OVER 12 TRE [8,5] TOO MANY PLUGGED MODULES [8,8] HW-RESYNCH[8,26] RACH-CATCHER-LOST[8,30] BCB-LINK[8,31] IOM-LINK[8,32] MODULE-INSERTED[8,247] RESET[8,248] RESTART[9,1] EXT-ALARM (Default)[9,2] EXT-ALARM (Default)[9,3] EXT-ALARM (Default)[9,4] EXT-ALARM (Default)[9,5] EXT-ALARM (Default)[9,6] EXT-ALARM (Default)[9,7] EXT-ALARM (Default)[9,8] EXT-ALARM (Default)[9,9] EXT-ALARM (Default)[9,10] EXT-ALARM (Default)[9,11] EXT-ALARM (Default)[9,12] EXT-ALARM (Default)[9,13] EXT-ALARM (Default)[9,14] EXT-ALARM (Default)[9,15] EXT-ALARM (Default)[9,16] EXT-ALARM (Default)[9,17] EXT-ALARM (Default)[9,18] EXT-ALARM (Default)[9,19] EXT-ALARM (Default)[9,20] EXT-ALARM (Default)[9,21] EXT-ALARM (Default)[9,22] EXT-ALARM (Default)[9,23] EXT-ALARM (Default)[9,24] EXT-ALARM (Default)[9,25] EXT-ALARM for A9110-E (Default) [9,26] EXT-ALARM for A9110-E (Default) [9,27] EXT-ALARM for A9110-E (Default) [9,28] EXT-ALARM for A9110-E (Default) [9,29] EXT-ALARM for A9110-E (Default) [9,30] EXT-ALARM for A9110-E (Default) [9,31] EXT-ALARM for A9110-E (Default) [9,32] EXT-ALARM for A9110-E (Default) [9,33] EXT-ALARM for A9110-E (Default) [9,34] EXT-ALARM for A9110-E (Default) [9,35] EXT-ALARM for A9110-E (Default) [9,36] EXT-ALARM for A9110-E (Default) [9,37] EXT-ALARM for A9110-E (Default) [9,38] EXT-ALARM for A9110-E (Default) [9,39] EXT-ALARM for A9110-E (Default) [9,40] EXT-ALARM for A9110-E (Default) [9,41] EXT-ALARM for A9110-E (Default) [9,42] EXT-ALARM for A9110-E (Default) [9,43] EXT-ALARM for A9110-E (Default) [9,44] EXT-ALARM for A9110-E (Default) [9,45] EXT-ALARM for A9110-E (Default) [9,46] EXT-ALARM for A9110-E (Default) [9,47] EXT-ALARM for A9110-E (Default)[9,48] EXT-ALARM for A9110-E (Default) [9,49] EXT-ALARM for A9110-E (Default) [9,50] EXT-ALARM for A9110-E (Default) [9,51] EXT-ALARM for A9110-E (Default) [9,52] EXT-ALARM for A9110-E (Default) [9,53] EXT-ALARM for A9110-E (Default) [9,54] EXT-ALARM for A9110-E (Default) [9,55] EXT-ALARM for A9110-E (Default) [9,56] EXT-ALARM for A9110-E (Default) [10,1] RSL-LINK[10,3] RX-CABLE[10,10] TRE-VSWR[10,11] ANTENNA-VSWR-WARNING[10,12] ANTENNA-VSWR-URGENT[10,21] MODULE-FRAME-SIGNAL[10,22] MODULE-CLOCK-SIGNAL[10,51] MODULE-NOT-PRESENT[10,234] IOM-DISCONNECTION[10,237] HW-DEGRADED[10,239] HW-FAILURE[10,248] RESTART[10,248] RESTART (RA)[11,22] LOOP-TO-EQUIPMENT[11,50] LOSS-OF-INCOMING-SIGNAL[11,66] AIS-2M[11,81] LOSS-OF-FRAME-ALIGNMENT[11,86] LOSS-OF-CRC-MULTIFRAME-ALIGNMENT [11,99] ERROR-RATE >E-3[11,100] ERROR-RATE >E-4[11,102] ERROR-RATE >E-6[11,176] REMOTE-ALARM-INDICATION告警描述指示信令状态异常无法连接M SC指示信令状态异常在DTC(A9120 BSC)或TP-GSM(A9130)上发现RAI告警。

基站底噪异常问题分析报告[阿尔卡特-朗讯]解读

基站底噪异常问题分析报告[阿尔卡特-朗讯]解读

基站底噪异常问题分析报告阿尔卡特-朗讯2009年5月目录1问题描述 (3)1.1 RX1 RSSI升高,RX2正常 (3)1.2 RX1,RX2 RSSI均升高 (3)2基站自身质量问题排查 (3)2.1 基站硬件指标检测 (3)2.2基站接大功率假负载测试 (3)2.3基站接外置滤波器和频谱仪测试 (4)2.4 基站发射口开路测试 (5)3 外部问题排查 (5)3.1测试方法 (5)3.2使用设备和仪器 (6)3.3原理和设备连接 (6)3.4测试结果 (6)4外部问题原因分析 (6)4.1外界干扰(通过空中) (7)4.1.1无线公话电话机 (7)4.1.2 GSM基站,微波设备上产生的杂散 (7)4.2 干放、室内分布系统,直放站输出的影响 (7)4.2.1干放泄露 (7)4.2.2室内分布系统和直放站的影响 (8)4.3 天馈系统无源交调的影响 (9)5结论 (11)附录1:全国处理案例汇总 ................................................................. 错误!未定义书签。

附录2:问题具体定位方法 ................................................................. 错误!未定义书签。

1问题描述最近,一些省市发现部分DO载频开通后,C网基站底噪RSSI明显抬高,受影响严重的基站,甚至导致语音掉话。

通过到现场进行测试和分析,发现问题主要分两种:1.1 RX1 RSSI升高,RX2正常典型站的配置是DO载波与原1X载波通过Port1(主集)发射,而Port2(分集)只有接收没有发射载波。

当打开DO载波后,通过软件可以看到RX1 的RSSI升高(恶化10dB到20dB不等),而RX2基本保持正常( -80dBm左右)。

通过频谱仪直接观察接收频段的杂散,则发现存在相应的杂散。

阿尔卡特网管告警含义-zj

阿尔卡特网管告警含义-zj
Communication: Excessive BER Loss Of Frame Loss Of Pointer Loss Of Signal Payload Mismatch Underfying Resource Unavailable Resource isolation Alarm Indication Signal Degraded Signal Unequipped FrequencyOffest LossOfTimingSources Remote Defect Indication

Equipment: Cabling Problem Power Problem Replaceable Unit Missing Replaceable Unit Problem Replaceable Unit Type Mismatch Cooling Fan Failure Internal Communicateion Problem Unconfigured Equipment Present
LEVEL Major Major Major Major Major minor Minor Warning
中文名称 风扇告警线问题 电源问题 单板不存在 单板故障 单板配置和软件不匹配 风扇故障 内部通信问题 机盘没有被配置
SSF 指信号中断,一般为某端口LOS,但是做了交叉. Unequipped 指电路告警,表明电路上时隙没有对应上.
LEVEL Major Major Major Major Major Major Major Major Minor Minor minor minor Warning
中文名称 严重误码 贞丢失 指针丢失 信号丢失 静负荷不匹配 潜在资源不可利用 脱管 信号丢失 信号劣化 信号未装载 频偏 丢失时钟 远端失效告警

阿朗基站设备告警查看及命令操作

阿朗基站设备告警查看及命令操作

7
Compact4.0基站 基站
8
Compact4.0基站 基站
板件功能介绍 (1) URC/URC-II = CRC ) (2) UCR/MCR = CBR ) (3) OMQ = OM ) (3) CTU/CTU-II = TFU CTU-II = CTU + OMQ ) (4) CMU = CCU ) (5) C1PAM/C2PAM = ULAM/A-CmLAM ) (6) 2 CPC-A + 1 CPC-B = PCU Compact4.0 一、二载频基 ) 站使用 2 CPC-A + 1 CPC-B,三、四载频基站时用 CPC-A + 2 四载频基站时用2 , CPC-B HIOU 传输接口盘,类似于 传输接口盘,类似于Modcell基站的 基站的FIT。在提供传输接口的 基站的 。 同时,又提供功放的控制总线, 同时,又提供功放的控制总线,提供本机联调接口
C网阿朗基站 设备告警查看及命令操作
无线网络中心 2010.5
阿尔卡特朗讯基站简介
目前滁州现网主要存在下列4种设备型号 目前滁州现网主要存在下列 种设备型号: 种设备型号 Modcell基站 基站 Compact3.0基站 基站 Compact4.0基站 基站 4400基站 4400基站
1
24
退出命令窗口页面
键入exit退出命令窗口页面,再按F6键回到主菜单 键入exit退出命令窗口页面,再按F6键回到主菜单 exit退出命令窗口页面 F6
25
26
16
TFU状态 状态
17
CBR状态 状态
18
功放状态
19
CCU状态 状态
20
进入命令窗口页面
进入命令窗口页面

阿尔卡特基站告警定义与分级(2元)

阿尔卡特基站告警定义与分级(2元)

一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级 一级
43000 43001 43002 43003
一级 一级 一级 一级
3 3 3 3 2
At least, one sleeping Cell is detected into the BSS BTS-ADAPT [74] ACCESS-FAIL [247] BTS-ADAPT [74] BLOCKED-FROM-USE [20] BTS-ADAPT BTS-ADAPT BTS-ADAPT BTS-ADAPT [74] [74] [74] [74] DOWNLOAD-FAIL [246] EQUIPMENT-FAULT [128] LOOP-TO-EQUIP [22] MEMORY-FAULT [130]
7241 7240 7250 7033 7032 7248 8250 8251 1016482 6034 6038 6039 6246 6050 6037 6036 6049 6241 6015 6017 6019 6002 6240 6250 6043 6018 6247 6048 6056 6055 6051 6053 6054 6042 6005 6006 10012 10239 10022 10051 10003 10010 3246 3011 3014 10011 10237
告警辅助字段 11066 11099 11100 11102 11086 11176 11081 11022 11050 1012 1003 1246 1241 1008 1006 1022 1007 1031 1240 1250 1001 5015 5013 5005 5032 5020 5014 5023 5000 5011 5024 5006 5007 4246 4001 4010 4006 4017 4015 4240 4250 4255 4247 7006 7035 7034 7005 7246 7007 7008 7014 7031 7243 7242

阿尔卡特朗讯IP Touch 4068话务员话机用户手册说明书

阿尔卡特朗讯IP Touch 4068话务员话机用户手册说明书

Alcatel-Lucent EnterpriseOmniPCX Enterprise PurpleCommunication Server阿尔卡特朗讯 IP T ouch 4068 话务员话机用户手册十月 20218AL90607CNBA 版 1法律声明:阿尔卡特朗讯(Alcatel-Lucent)的名称和商标均由诺基亚(Nokia)授权于ALE(Alcatel-Lucent Enterprise)使用。

若要查阅ALE公司旗下公司使用的其他商标,请访问:/en/ legal/trademarks-copyright。

所有其他商标均为其所属拥有者的财产。

此处所提供的信息如有变更恕不能另行通知。

ALE公司概不承担任何所载资料准确性的责任。

© 阿尔卡特朗讯企业通信 2021年版权所有。

/所有国家保留一切权利。

/zh-cn免责声明尽管已努力验证本文件所含信息的完整性和准确性,但本文档是“按现状”提供。

如需获得关于交叉兼容、产品限制、软件政策和功能列表的更准确信息,请参阅业务合作伙伴网站上发布的准确文档。

为了继续发展产品,ALE International 保留随时对本文件及其所述的产品进行改进的权利,恕不另行通知且不承担任何义务。

CE标志表示此产品符合以下理事会指令:•无线电设备指令 2014/53/EU•非无线设备(包括有限电信终端设备)指令2014/35/EU和2014/30/EU•ATEX设备指令2014/34/EU•2011/65/EU (RoHS)•2012/19/EU (WEEE)章 1介绍1.1概览 (7)1.2话机总视图 (8)1.3话机显示屏 (9)1.3.1菜单页面 (10)1.3.2main (perso)页面 (10)1.3.3下一页 (10)1.3.4rt&hold页面 (11)1.3.5预占页面 (11)1.4话机标准键 (12)1.4.1软功能键(动态功能键) (12)1.4.2固定功能键 (14)1.4.3可编程按键 (15)1.5话机 LED (16)1.6连接可选设备 (16)1.6.1耳塞 (16)1.6.2外部站扬声器 (16)1.7把 PC 插入话机 (16)章 2基本功能2.1话务员话机进入服务( (17)2.2呼叫某个号码的方法 (17)2.2.1直接拨号 (17)2.2.2通过话机目录呼叫 (17)2.2.3按姓名拨号(呼叫) (18)2.2.4快速拨号呼叫 (19)2.3呼叫内部用户 (20)2.3.1预留(锁定)内部用户话机 (20)2.3.2被叫话机空闲 (20)2.3.3被叫话机占线 (22)2.3.4特殊情况:无法接通或已转移的话机 (24)2.4呼叫外部用户 (29)2.5应答呼叫 (30)2.5.1自动/手动应答 (30)2.5.2应答内部呼叫 (30)2.5.3应答外部呼叫 (31)2.5.4应答到达话务组呼叫 (32)2.5.5话务员不立即应答 (33)2.5.6应答回叫请求 (33)2.6将呼叫置于保持状态 (35)2.7查询呼叫 (35)2.7.1发送给内部用户的查询呼叫 (35)2.7.2发送给外部用户的查询呼叫 (38)2.7.3初始化三方会议 (39)2.8呼叫转移(路由) (40)2.8.1自动/手动转移 (40)2.8.2转移至占线话机 (40)2.9将与会者路由至会聚式会议 (42)2.9.1会议线路空闲 (42)2.9.2会议正在进行中 (42)章 3附加功能3.1使用串联分机路由 (43)3.2使用分机和预占释放路由 (44)3.3在 DTMF 透明模式中拨号 (46)3.4发送校准切断或闪存 (46)3.5临时保持自动转移 (47)3.6目录号码监管 (47)3.7单个呼叫路由 (48)3.7.1Indiv routing键显示在main (perso)页面 (48)3.7.2Indiv routing键显示在Smart Display Module上 (48)3.8网络/网络传送 (48)3.8.1Net/Net键显示在main (perso)页面 (49)3.8.2Net/Net键显示在Smart Display Module上 (49)3.9中继组监管 (49)3.10O/S 中继监管 (50)3.11单个保持 (50)3.11.1Indiv hold键显示在main (perso)页面 (50)3.11.2Indiv hold键显示在Smart Display Module上 (50)3.12呼叫演示 (51)3.13特权转移 (51)3.14唤醒/约会提醒 (52)3.14.1唤醒创建 (52)3.14.2唤醒取消 (55)章 4从话务员话机管理4.1管理概述 (58)4.2菜单页面结构 (58)4.3定制您的话务员话机(设置) (59)4.3.1分配可编程键 (59)4.3.2选择应答并转接操作模式 (64)4.3.3选择显示语言 (64)4.3.4配置振铃选项 (64)4.3.5更改密码 (66)4.3.6连接可选设备 (66)4.3.7调节Smart Display Module对比度 (67)4.3.8配置蓝牙设备(可选) (68)4.4检查话务员话机配置 (68)4.4.1读取话务员话机 IP 参数 (69)4.4.2读取话务员话机软件版本 (69)4.4.3运行电话测试 (70)4.5选择话务组状态 (70)4.6选择实体状态 (71)4.7退出/登录 (72)4.8信息 (73)1.1 概览话务员话机(按组设置)的目的是确保高效路由外部呼叫,以及适当时,按需呼叫外部号码。

朗讯紧急告警说明

朗讯紧急告警说明

E12cLOS; 2M bit/s Loss of input signal告警描述:2Mbit/s端口无输入信号。

收到全“0”码。

告警等级:紧急告警类型:传输本地现象:支路单元盘上LED告警灯闪亮。

UPL上紧急告警灯亮。

紧急站告警回路闭合。

LANcANM; Ethernet interface Auto negotiation mismatch 告警描述:检测到本地与远端以太网设备的应用技术不匹配。

告警等级:紧急告警类型:传输本地现象:无告警原因:自协商功能失效,无法找到与远端以太网设备相同的技术。

相同技术可以是:10Base-T半双工,10Base-T全双工,100Base-T半双工;100Base-T全双工。

注:当自协商功能关闭时,特定相同模式工作于10Base-T半双工。

MS1cSSF; STM-N MS Network connection unavailable (N=1,4,16,64)告警描述:激活的MS(复用)段失效,网络链路故障。

这是MS接收失效,如:STM-N信号丢失,STM-N帧定位丢失或STM-N单元盘设备故障。

告警等级:紧急告警类型:传输本地现象:UPL上紧急告警灯亮。

紧急站告警回路闭合。

向上游方向,激活MS远端缺陷指示(MSRDI)。

在装配信号方向,插入告警信号。

告警原因:本节点或上游节点的1个或1个以上STM-N,MS,或VC4失效,且无法被保护。

P12ScAIS; 2Mbit/s Alarm indication signal received告警描述:接收到的整个2Mbit/s信号,包括0时隙为全“1”码。

上游节点设备(非传输系统)检测到故障并产生AIS。

告警等级:信息告警类型:传输本地现象:UPL上信息告警灯亮。

告警原因:上游设备检测到故障向下游信号插入AIS。

注:如果设定支路定时模式,则会发生定时保护倒换请求。

PMcUPF; Pluggable Module failure告警描述:插入模块告警。

IP话机使用手册

IP话机使用手册

阿尔卡特IP话机使用手册适用范围:公司内部所有IP话机一、基本功能:1.1、转接功能:双方通话完毕后,需要将对方电话转到第三方,则使用转接功能具体操作:通话过程当中,拨打需要转接到的第三方号码,按下转接键,即可完成转接功能。

操作案例:(133)通话过程当中,将对方电话转给第三方158的操作)4008话机操作:133通话中,拨打158分机号,按下右下角的6个功能键的倒数第二个“”,完成转接操作。

4068/4028话机操作:133通话中,拨打158分机号,按下屏幕上显示的“转接”对应的功能键,完成转接操作。

1.2、呼叫代接/驻留:其他分机振铃时,可以在本机上接听该分机的来电。

驻留/取回:在通话过程中,可以保持该通话,而对方无法听到本机这方,可在本机或其他分机上取回该通话。

使用操作:如133在振铃,无人接听和转移的状态下,在本机上按下*72→133即可接听该来电。

[驻留]133与158在通话过程当中,158按下*75→133驻留与133的通话,在163分机上再按下*75→133取回该通话,继续同133通话。

1.3、转移服务:可以将拨打至本机的所有来电转移到指定的电话号码(其他同事分机/本人手机/家庭电话等)1.立即转移(*61):立刻将所有来电进行转移到指定的电话号码,直至取消转移为止。

2.遇忙转移(D01):正在通话中,有其他号码呼叫本分机时,可转移到指定的电话号码。

(本功能未定义快捷键方式。

)3.无应答转移(*62):其他电话呼叫本机,而本机长时间未应答时,自动将来电转到指定的号码。

4.忙/无应答转移(*63):其他电话呼叫本机,本机忙或者长时间未应答时,自动将来电转到指定的号码。

5.取消转移(*64):取消在话机上设置的转移。

6.取消跟随(D05):取消在话机上设置的跟随(本功能未定义快捷键方式。

)7.远程转移(*88):指定本机拨打某个号码时,转移到另外一个指定的号码。

(相当于远程操控将某个分机立即转移到其他的分机。

朗讯告警说明

朗讯告警说明

S022CNMetropolis® ADM Universal城域系列通用型分插复用器操作与维护课程故障排除手册版本 5.0S022CN-5.0-AMTCG.zh.A4第1版2006年4月朗讯科技 – 专利产品本文件含有朗讯科技的专利信息未经许可不得披露或使用版权所有 © 2005 朗讯科技非公开出版物保留所有权利朗讯科技(中国)客户培训中心本故障排障手册是参考Metropolis® ADM Universal 系统软件版本5.0(R5.0)。

为方便使用本手册,除告警条目保留原文(英文)外,其他均已译成中文,供学员参考。

其中告警严重等级和告警类别的说明如下:SDH告警严重等级:Prompt 紧急Deffer 延迟Information 信息告警类别Transmission<传输> 关于传输、定时的告警Equipment<设备> 关于单元盘、电源、风扇及配置的告警Processing<处理> 关于软件故障、重启动等告警Quality of service<业务质量> 关于性能监测的告警Environment<环境> 关于环境的告警Management<管理> 关于网管管理的告警序号告警名称1.1GEcANM; 1Gigabit Ethernet interface Auto Negotiation Mismatch (1)2.1GEcLOS; 1Gigabit Ethernet interface Loss of input signal (1)3.1GEcNES; 1Gigabit Ethernet interface Not expected input signal (1)4.E11cLOS; 1.5 Mbit/s Loss of input signal (1)5.E11cNES; 1.5 Mbit/s interface Not expected input signal (2)6.P11OTMcSW; 1.5 Mbit/s output timing mode change (2)7.P12ScAIS; 2Mbit/s Alarm indication signal received (2)8.E12cLOS; 2M bit/s Loss of input signal (2)9.P12ScLOFM; 2Mbit/s Loss of frame alignment (3)10.P12cDEG; 2Mbit/s Moderate block error rate (3)11.P12ScNCM; 2Mbit/s No CRC4 Multiframe alignment signal (3)12.E12cNESM; 2Mbit/s Not expected input signal (4)13.P12OTMcSW; 2 Mbit/s output timing mode change (4)14.P12ScRDI; 2Mbit/s Remote defect indicator (4)15.P12cRNCM; 2Mbit/s Remote No CRC-4 Multiframe alignment signal (4)16.E31cAIS; 34 Mbit/s AIS (5)17.E31cLOS; 34 Mbit/s Loss of input signal (5)18.E31cNES; 34 Mbit/s Not expected input signal (5)19.E32cLOS; 45 Mbit/s Loss of input signal (5)20.E32cNES; 45 Mbit/s Not expected input signal (6)21.E4cLOS; 140 Mbit/s Loss of input signal (6)22.E4cNES; 140 Mbit/s Not expected input signal (6)23.ALMcINH; Alarming inhibited (7)24.AU3cAIS; AU-3 Alarm indication signal received (7)25.AU3cLOP; AU-3 Loss of pointer (7)26.AUcAIS; AU-4 Alarm indication signal received (7)27.AUcLOP; AU-4 Loss of pointer (8)28.AU4cAISC; AU-4-4c Alarm indication signal received (8)29.AU4cLOPC; AU-4-4c Loss of pointer (8)30.AU16cAISC; AU-4-16c Alarm indication signal received (8)31.AU16cLOPC; AU-4-16c Loss of pointer (9)32.BCLANcUPF; BC LAN failure (9)33.OBALSRcFLR; Booster amplifier laser failure (9)34.VC4cPPE; Circuit provisioning error (9)35.UPcRST; CP reset in progress (10)36.XCCcINC; Cross-connect inconsistency (10)cUPF; Cross connect unit failure (10)cEQF; Cross connect unit failure - protected (10)cUNI; Cross connect Unit removed (10)40.DCNTAPcCONF; DCN-Tunnel auto provisioning configuration error (11)41.DS3cDEG; DS3 Line BER degraded (11)42.TIDcFLR; Duplicate node name (11)43.EMACcLOF; Encapsulated-MAC loss of frame alignment (11)NcANM; Ethernet interface Auto negotiation mismatch (12)NcLOS; Ethernet interface Loss of input signal (12)NcNES; Ethernet interface Not expected input signal (12)47.ATPcPRM; Extra traffic preempted (12)48.FANcFANX; Fan unit failure (13)49.FANcPWR; Fan unit power failure (13)50.FANcUNI; Fan unit removed (13)51.BAUcTYM; From backplane received AU-type does not match expected AU-type (13)52.GEcPLL; GBE Local Link Aggregation partial link loss (13)53.GEcTLL; GBE Local Link Aggregation total link loss (14)54.I2CcUPF; I2C-bus failure (14)55.INTCOMcRPF; Internal comunication interface fault protected (14)56.POWc1LS; Input voltage failure on PSU (15)57.DCNcCONF; IS-IS configuration error (15)58.DCNcREPAIR; IS-IS Level-2 Area repair, transmission/configuration error (15)NDPcTHR15; LAN Dropped packets threshold crossing 15-min (15)NDPcTHR24; LAN Dropped packets threshold crossing 24-hrs (15)61.IPcUPF; LAN unit failure (16)62.IPcEQF; LAN unit failure - protected (16)63.IPcUNI; LAN Unit removed (16)64.LSRcEDG; Laser degradation (16)65.LSRcFLR; Laser failure (17)66.MLQ2; Loss of Q2-communication (17)67.POWcLSV; Loss of secondary input voltage (17)68.DCNBUcLOST; Mandatory IS-IS parameters missing (18)69.MACcVLANOVFW; Maximum number of VLAN instances exceeded (18)70.MDcIPX; MDI #X :< 用户输入名> (18)71.MS16cLIVm; MS-16 Ring comm. server network address protocol failure/version mismatch1872.NIDcFLR; Node ID conflict (18)73.NUTRcPND; Non-preemptable unprotected traffic switch request pending (19)74.SYSMEMcNVM; NVM contents invalid (19)75.P12SNBBEcTHR15; P12s Near-end background block error thresh cross 15-min (19)76.P12SNBBEcTHR24; P12s Near-end background block error thresh cross 24-hrs (19)77.P12sNEScTHR15; P12s Near-end errored seconds threshold crossing 15-min (19)78.P12sCNEScTHR24; P12s Near-end errored seconds threshold crossing 24-hrs (20)79.P12sCNSEScTHR15; VC-4-4c Near-end severely ES threshold crossing 15-min (20)80.P12sCNSEScTHR24; P12s Near-end severely ES threshold crossing 24-hrs (20)81.P12SCNUAScTHR15; P12s Near-end unavailable seconds threshold crossing 15-min (20)82.P12SCNUAScTHR24; P12s Near-end unavailable seconds threshold crossing 24-hrs (20)83.PBcUPF; Paddle board failure (21)84.PBcEQF; Paddle board failure - protected (21)85.PBcUNI; Paddle board removed (21)86.VC4HPcPAF; Path integrity failure (21)87.PIcUPF; Plesiochronous Interface Unit failure (21)88.PIcEQF; Plesiochronous Interface Unit failure- protected (22)89.PIcUNI; Plesiochronous Interface Unit removed (22)90.PMcUPF; Pluggable Module failure (22)91.PMcEQF; Pluggable Module failure - protected (22)92.PMcUNI; Pluggable Module removed (23)93.PUcUPF; Power Unit failure (23)94.PUcEQF; Power Unit failure - protected (23)95.PUcUNI; Power Unit removed (23)96.PSUc1EQ; PSU failure (24)97.PSFcEQR; PSF removed (24)NcTRM; Q-LAN termination loopback failed (24)99.POWcBAT; Racktop battery failure (24)100.POWcFUS; Racktop fuse failure (25)101.AU4cTYM; Received AU-type does not match expected type AU4 (25)102.RGU16EQF; Regenerator failure (25)103.RGU16cDEG; Regenerator laser degradation (25)104.RGU16cEQR; Regenerator removed (25)105.RINGcOPEN; Ring incomplete/open (26)106.RINGcSTART; Ring startup in progress (26)107.RS16cLIVm; RS-16 Ring comm.server network address protocol failure/version mismatch (26)108.SCTcUPF; SCT Unit failure (26)109.SITEcPROV; Site provisioning conflict (27)110.SFTWcDWN; Software download in progress (27)111.SQcSUS; Squelch map update suspended (27)112.DISCON; Station alarms disconnected (27)113.MTcAIS; Station clock input alarm indication signal (28)114.MTcLOF; Station clock input Loss of frame alignment (28)115.MTcLOS; Station clock input Loss of signal (28)116.MTcNES; Station clock input Not expected signal (28)117.TSCOcSQ; Station clock output squelched (29)118.STMNcLOF; STM-N Loss of frame alignment (N=1, 4, 16,64) (29)119.STMNcLOS; STM-N Loss of input signal (N=1, 4, 16,64) (29)120.MS1cAIS; STM-N MS Alarm indication signal received (N=1, 4, 16,64) (30)121.MS1cBDEG; STM-N MS Moderate block error rate (N=1, 4, 16,64) (30)122.MS1NBBDEcTHR15; STM-N MS Near-end background block error thresh cross 15-min (N=1,4,16,64) (30)123.MS1NBBEcTHR24; STM-N MS Near-end background block error thresh cross 24-hrs (N=1,4,16,64) (30)124.MS1NEScTHR15; STM-N MS Near-end errored seconds threshold crossing 15-min (N=1,4, 16,64) (31)125.MS1NEScTHR24; STM-N MS Near-end errored seconds threshold crossing 24-hrs (N=1,4,16,64) (31)126.MS1NSEScTHR15; STM-N MS Near-end severely ES threshold crossing 15-min (N=1,4,16,64) (31)127.MS1NEScTHR24; STM-N MS Near-end severely ES threshold crossing 24-hrs (N=1, 4,16,64) (31)128.MS1NUAScTHR15; STM-N MS Near-end unavailable seconds threshold crossing 15-min (N=1, 4, 16,64) (31)129.MS1NUAScTHR24; STM-N MS Near-end unavailable seconds threshold crossing 24-hrs (N=1, 4, 16,64) (32)130.MS1cSSF; STM-N MS Network connection unavailable (N=1, 4, 16,64) (32)131.MS1cFOP; STM-N MS Protection switching protocol failure (N=1, 4, 16,64) (32)132.MS1cREM; STM-N MS Remote Defect Indicator (N=1, 4, 16,64) (33)133.STMNcNES; STM-N Not expected input signal (N=1, 4, 16,64) (33)134.RS1cTIM; STM-N RS trace identifier mismatch (N=1, 4, 16,64) (33)135.LTX16cALS; STM-16 ALS disabled (33)136.MS-NcBYF; STM-N APS byte failure (N-16, 64) (34)137.MS-NcCHF; STM-N APS channel failure (N-16, 64) (34)138.REG16CONcFLR; STM-16 fault locate fails (34)139.MS-NcFIC; STM-N Fiber connection conflict (N-16, 64) (34)140.MS16cLSROFF; STM-16 Laser switched off (35)141.STM-NcPLOS; STM-N LOS and restart pulse detected (N-16, 64) (35)142.STM-NcPLOSP; STM-N LOS and restart pulse detected – protected (N-16, 64) (35)143.STM-NcLOFP; STM-N Loss of frame alignment – protected (N-16, 64) (35)144.STM-NcLOSP; STM-N Loss of input signal- protected (N-16, 64) (36)145.STM-NcDEG; STM-N RS Moderate bit error rate (N-16, 64) (36)146.RS-N NBBEcTHR15; STM-N RS Near-end background block error thresh cross 15-min (N-16,64) (36)147.RS-N NBBEcTHR24; STM-N RS Near-end background block error thresh cross 24-hrs (N-16,64) (36)148.RS-N NEScTHR15; STM-N RS Near-end errored seconds threshold crossing 15-min (N-16, 64) (37)149.RS-N NEScTHR24; STM-N RS Near-end errored seconds threshold crossing 24-hrs (N-16, 64) (37)150.RS-N NSEScTHR15; STM-N RS Near-end severely ES threshold crossing 15-min (N-16, 64)37 151.RS-N NSEScTHR24; STM-N RS Near-end severely ES threshold crossing 24-hrs (N-16, 64).37 152.RS-N NUAScTHR15; STM-N RS Near-end unavailable seconds threshold crossing 15-min (N-16, 64) (37)153.RS-N NUAScTHR24; STM-N RS Near-end unavailable seconds threshold crossing 24-hrs (N-16, 64) (38)154.RS-NcTIM; STM-N RS trace identifier mismatch (N-16, 64) (38)155.SYSMEMcSWM; SW version mismatch (38)156.SIcUPF; Synchronous interface unit failure (38)157.SIcEQF; Synchronous interface unit failure - protected (39)158.SIcUNI; Synchronous interface unit removed (39)159.SCcEQF; System controller failure (39)160.TBACKcUPM; System timing in backup state (39)161.SYScALMT; Test station alarms (40)162.TLINKcFLR; Timing link failed (40)163.TLINKcUNEQ; Timing link unequipped (40)164.STM-NcTTD; Trace tone detected (N-16, 64) (40)165.SQcAIS; Traffic squelched (40)166.TUcAIS; TU-12 Alarm indication signal received (41)167.TUcLOP; TU-12 Loss of pointer (41)168.TU3cAIS; TU-3 Alarm indication signal received (41)169.TU3cLOP; TU-3 Loss of pointer (41)170.VC3NBBEcTHR15; TU-3 Near-end background block errors thresh cross 15-min (42)171.VC3NBBEcTHR24; TU3 Near-end background block errors thresh cross 24-hrs (42)172.VC3NEScTHR15; TU-3 Near-end errored seconds threshold crossing 15-min (42)173.VC3NEScTHR24; TU-3 Near-end errored seconds threshold crossing 24-hrs (42)174.VC3NSEScTHR15; TU-3 Near-end severely ES threshold crossing 15-min (42)175.VC3NSEScTHR24; TU-3 Near-end severely ES threshold crossing 24-hrs (43)176.VC3NUAScTHR15; TU-3 Near-end unavailable seconds threshold crossing 15-min (43)177.VC3NUAScTHR24; TU-3 Near-end unavailable seconds threshold crossing 24-hrs (43)178.VC12NBBEcTHR15; TU-12 Near-end background block errors threshold crossing 15-min (43)179.VC12NBBEcTHR24; TU-12 Near-end background block errors threshold crossing 24-hrs (43)180.VC12NEScTHR15; TU-12 Near-end errored second threshold crossing 15-min (44)181.VC12NEScTHR24; TU-12 Near-end errored second threshold crossing 24-hrs (44)182.VC12NSEScTHR15; TU-12 Near-end severely ES threshold crossing 15-min (44)183.VC12NSEScTHR24; TU-12 Near-end severely ES threshold crossing 24-hrs (44)184.VC12NUAScTHR15; TU-12 Near-end unavailable seconds threshold crossing 15-min (44)185.VC12NUAScTHR24; TU-12 Near-end unavailable seconds threshold crossing 24-hrs (44)186.UNITcINIT; Unit in initialisation (45)187.UPUS; Unit present in unassigned slot (45)188.UPLcEQF; UPL failure (45)189.UPLcUPR; User Panel removed (45)190.VC11cDEG; VC-11 Moderate block error rate (46)191.VC11NBBEcTHR15; VC-11 Near-end background block errors thresh cross 15-min (46)192.VC11NBBEcTHR24; VC-11 Near-end background block errors thresh cross 24-hrs (46)193.VC11NEScTHR15; VC-11 Near-end errored seconds threshold crossing 15-min (46)194.VC11NEScTHR24; VC-11 Near-end errored seconds threshold crossing 24-hrs (46)195.VC11NSEScTHR15; VC-11 Near-end severely ES threshold crossing 15-min (47)196.VC11NSEScTHR24; VC-11 Near-end severely ES threshold crossing 24-hrs (47)197.VC11NUAScTHR15; VC-11 Near-end unavailable seconds threshold crossing 15-min (47)198.VC11NUAScTHR24; VC-11 Near-end unavailable seconds threshold crossing 24-hrs (47)199.VC11cSSF; VC-11 Network connection server signal fail (47)200.VC11cTIM; VC-11 Path trace identifier mismatch (48)201.VC11cPLM; VC-11 Payload mismatch (48)202.VC11cRDI; VC-11 Remote defect indicator (48)203.VC11cUNEQ; VC-11 Unequiped (48)204.VC12cBDEG; VC12 Moderate block error rate (48)205.VC12cSSF; VC-12 Network connection server signal fail (49)206.VC12NBBEcTHR15; VC-12 Near-end background block errors threshold crossing 15-min (49)207.VC12NBBEcTHR24; VC-12 Near-end background block errors threshold crossing 24-hrs (49)208.VC12NEScTHR15; VC-12 Near-end errored second threshold crossing 15-min (49)209.VC12NEScTHR24; VC-12 Near-end errored second threshold crossing 24-hrs (49)210.VC12NSEScTHR15; VC-12 Near-end severely ES threshold crossing 15-min (50)211.VC12NSEScTHR24; VC-12 Near-end severely ES threshold crossing 24-hrs (50)212.VC12NUAScTHR24; VC-12 Near-end unavailable seconds threshold crossing 15-min (50)213.VC12NUAScTHR24; VC-12 Near-end unavailable seconds threshold crossing 24-hrs (50)214.VC12cTIM; VC-12 Path trace identifier mismatch (50)215.VC12cPLM; VC-12 Payload mismatch (51)216.VC12cRDI; VC-12 Remote Defect Indicator (51)217.VC12cUNEQ; VC-12 Unequipped (51)218.VC12VcLOA; VC-12 Virtual concatenated Loss of alignment (51)219.VC12VcLOM; VC-12 Virtual concatenated Loss of multiframe (52)220.VC12VcSQM; VC-12 Virtual concatenated sequence mismatch (52)221.VC12cSSF; VC-12 Virtual concatenated server signal fail (52)222.VC3cDEG; VC-3 Moderate block error rate (52)223.VC3cSSF; VC-3 Network connection server signal fail (53)224.VC3NBBEcTHR15; VC-3 Near-end background block errors thresh cross 15-min (53)225.VC3NBBEcTHR24; VC-3 Near-end background block errors thresh cross 24-hrs (53)226.VC3NEScTHR15; VC-3 Near-end errored seconds threshold crossing 15-min (53)227.VC3NEScTHR24; VC-3 Near-end errored seconds threshold crossing 24-hrs (53)228.VC3NSEScTHR15; VC-3 Near-end severely ES threshold crossing 15-min (54)229.VC3NSEScTHR24; VC-3 Near-end severely ES threshold crossing 24-hrs (54)230.VC3NUAScTHR15; VC-3 Near-end unavailable seconds threshold crossing 15-min (54)231.VC3NUAScTHR24; VC-3 Near-end unavailable seconds threshold crossing 24-hrs (54)232.VC3cTIM; VC-3 Path trace identifier mismatch (54)233.VC3cPLM; VC-3 Payload mismatch (54)234.VC3cRDI; VC-3 Remote defect indicator (55)235.VC3cUNEQ; VC-3 Unequipped (55)236.VC3VcLOA; VC-3 Virtual concatenated Loss of alignment (55)237.VC3VcLOM; VC-3 Virtual concatenated Loss of multiframe (55)238.VC3VcSQM; VC-3 Virtual concatenated sequence mismatch (56)239.VC3VcSSF; VC-3 Virtual concatenated server signal fail (56)240.VC3VcFOPR; VC-3 Virtual concatenated failure of protocol received (56)241.VC3VcFOPT; VC-3 Virtual concatenated failure of protocol transmitted (56)242.VC3VcLOPC; VC-3 Virtual concatenated loss of partial capacity (57)243.VC3VcLOTO; VC-3 Virtual concatenated loss of total capacity (57)244.VC3VcSSD; VC-3 Virtual concatenated server signal degrade (57)245.VC4cLOM; VC-4 Loss of multiframe (57)246.VC4cDEG; VC4 Moderate block error rate (57)247.VC4cSSF; VC-4 Network connection server signal fail (58)248.VC4NBBEcTHR15; VC-4 Near-end background block errors threshold crossing 15-min (58)249.VC4NBBEcTHR24; VC-4 Near-end background block errors threshold crossing 24-hrs (58)250.VC4NEScTHR15; VC-4 Near-end errored second threshold crossing 15-min (58)251.VC4NEScTHR24; VC-4 Near-end errored second threshold crossing 24-hrs (58)252.VC4NSEScTHR15; VC-4 Near-end severely ES threshold crossing 15-min (59)253.VC4NSEScTHR24; VC-4 Near-end severely ES threshold crossing 24-hrs (59)254.VC4NUAScTHR24; VC-4 Near-end unavailable seconds threshold crossing 15-min (59)255.VC4NUAScTHR24; VC-4 Near-end unavailable seconds threshold crossing 24-hrs (59)256.VC4cTIM; VC-4 Path trace identifier mismatch (59)257.VC4cPLM; VC-4 Payload mismatch (60)258.VC4cRDI; VC-4 Remote defect indicator (60)259.VC4cUNEQ; VC-4 Unequiped (60)260.VC4VcFOPR; VC-4 Virtual concatenated failure of protocol received (60)261.VC4VcFOPT; VC-4 Virtual concatenated failure of protocol transmitted (61)262.VC4VcLOA; VC-4 Virtual concatenated Loss of alignment (61)263.VC4VcLOM; VC-4 Virtual concatenated Loss of multiframe (61)264.VC4VcLOPC; VC-4 Virtual concatenated loss of partial capacity (61)265.VC4VcLOTC; VC-4 Virtual concatenated loss of total capacity (61)266.VC4VcSQM; VC-4 Virtual concatenated sequence mismatch (62)267.VC4VcSSD; VC-4 Virtual concatenated server signal degrade (62)268.VC4cSSF; VC-4 Virtual concatenated server signal fail (62)269.VC4CcDEG; VC-4-4c Moderate block error rate (62)270.VC4CNBBEcTHR15; VC-4-4c Near-end background block errors thresh cross 15-min (63)271.VC4CNBBEcTHR24; VC-4-4c Near-end background block errors thresh cross 24-hrs (63)272.VC4CNEScTHR15; VC-4-4c Near-end errored seconds threshold crossing 15-min (63)273.VC4CNEScTHR24; VC-4-4c Near-end errored seconds threshold crossing 24-hrs (63)274.VC4CNSEScTHR15; VC-4-4c Near-end severely ES threshold crossing 15-min (63)275.VC4CNSEScTHR24; VC-4-4c Near-end severely ES threshold crossing 24-hrs (63)276.VC4CNUAScTHR15; VC-4-4c Near-end unavailable seconds threshold crossing 15-min (64)277.VC4CNUAScTHR24; VC-4-4c Near-end unavailable seconds threshold crossing 24-hrs (64)278.VC4CcTIM; VC-4-4c Path trace identifier mismatch (64)279.VC4CcRDI; VC-4-4c Remote defect indicator (64)280.VC4CcSSF; VC-4-4c server signal fail (65)281.VC4CcUNEQ; VC-4-4c Unequiped (65)282.VC16CcDEG; VC-4-16c Moderate block error rate (65)283.VC16CNBBEcTHR15; VC-4-16c Near-end background block errors thresh cross 15-min (65)284.VC16CNBBEcTHR24; VC-4-16c Near-end background block errors thresh cross 24-hrs (65)285.VC16CNEScTHR15; VC-4-16c Near-end errored seconds threshold crossing 15-min (66)286.VC16CNEScTHR24; VC-4-16c Near-end errored seconds threshold crossing 24-hrs (66)287.VC16CNSEScTHR15; VC-4-16c Near-end severely ES threshold crossing 15-min (66)288.VC16CNSEScTHR24; VC-4-16c Near-end severely ES threshold crossing 24-hrs (66)289.VC16CNUAScTHR15; VC-4-16c Near-end unavailable seconds threshold crossing 15-min (66)290.VC16CNUAScTHR24; VC-4-16c Near-end unavailable seconds threshold crossing 24-hrs (66)291.VC16CcTIM; VC-4-16c Path trace identifier mismatch (67)292.VC16CcRDI; VC-4-16c Remote defect indicator (67)293.VC16CcSSF; VC-4-16c server signal fail (67)294.VC16CcUNEQ; VC-4-16c Unequiped (67)295.MACcVCM; VLAN configuration mismatch (68)296.WANDPcTHR15; WAN Dropped packets threshold crossing 15-min (68)297.WANDPcTHR24; WAN Dropped packets threshold crossing 24-hrs (68)cWUP; Wrong CC present (68)299.IPcWUP; Wrong LAN unit present (68)300.FANcWFUP; Wrong or failed FAN unit present (69)301.PBcWUP; Wrong Paddle broad present (69)302.PIcWUP; Wrong Plesiochronous interface present (69)303.PMcWUP; Wrong Pluggable Module present (69)304.SIcWUP; Wrong Synchronous interface unit present (69)305.WUPcEQF; Wrong unit- protected (70)1.1GEcANM; 1Gigabit Ethernet interface Auto Negotiation Mismatch告警描述:检测到本地与远端以太网设备的应用技术不匹配。

阿尔卡特SDH告警梳理原始信息表

阿尔卡特SDH告警梳理原始信息表

传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION 传输 阿尔卡特 OMSN/ION

阿朗LTE考试答案

阿朗LTE考试答案

阿朗LTE基本概念和测试题第一部分一、基本概念部分请说出下列缩写分别指什么物理设备D2U 机框FAN 风扇CB 载频板,通常叫C板BB 基带板,通常叫B板请简述以下常见的告警号所代表的告警含义IK4004030:CPRI1的LINK不好(一小区光路不通)IK4004031: CPRI2的LINK不好(二小区光路不通)IK4004032: CPRI3的LINK不好(三小区光路不通)IK4011010:RRU的1口驻波告警IK4011011: RRU的2口驻波告警IK4004082: GPS告警IK4007084: PCI冲突告警IK4007182: PCI混淆告警IK4305071: div告警(rru的2个发射口的rssi值的差值过大)二、操作部分1.请打开5620Sam网管操作图形页面,并统计显示当前critical,major,minor告警分别有共有多少项。

操作方法如下:A、在操作终端上双击5620SamClient图标,B、在弹出的类似如下的安全警告中都选择接受并继续运行。

C、在弹出的登陆对话页面中输入用户名alu,密码5620Sam! 点击login按钮D、在打开的登陆页面上点击Alarm Stastics选项卡,即可看到。

2.请查找告警名为LteCellDown的告警有哪些站点。

操作步骤如下(前面的步骤跟上题相同)A、在告警窗口中选择AlarmTable选项卡,在Alarm Name栏中选择LteCellDown,点击Search按钮。

3.请显示一个有LteCellDown告警的站点的板卡状态,并找出该站点上C板板卡的型号具体步骤如下:在Equipment-network窗口中Find一栏输入站名后回车,显示如下界面在找到的站点图标上点击鼠标右键,在弹出的选项卡中选择Launch NEM, 打开如下窗口单击上图中的图标弹出如下窗口单击HW Modules前面的“+”号展开,所有的硬件板卡就显示出来了。

阿尔卡特朗讯Wave Star OLS 1.6T DWDM系统OTU告警案例详解

阿尔卡特朗讯Wave Star OLS 1.6T DWDM系统OTU告警案例详解
告警 ,而 是透传之 。 下面举几个例子 , 通过 这些告警的分析 , 助于我 有 们 掌握如何定位故障 。
段落已经满配置, 是迄今为止该系统在工程实践中的最
高速率的应用 , 也是我 国迄今为止实际建成的最高速率 的传输大不 同 , S 16 尤
维普资讯
电 信工程技术与 标准化 20. 071
I瑾
阿尔卡特朗讯 WaeSa O S 16 v t L .T r D M系统 O U WD T 告警案例详解
陈学民
( 州 电信 分公 司 福 州 3 0 0 ) 福 5 0 3
摘 要 阿尔卡 特朗讯 Wa e Sa S 1 6 W D 系统可在 C波 段和 L波段上最 多支持 10路 1 G i s v trOL .T D M 6 0 bt 信号 , / 在国内电信运营 商中广泛应用 。其 中在 中国 电信南沿海干线 上应用的 C波段 8 0× 1Gbt s 0 i 系统 , 目前 已 / 接近满 配置 ,部 分段落 已经满 配置 ,是我国迄今为止实际建 成的最高速率 的传输 系统之 一。OL .T的 S 16
会有 Ic mig S M一 4 0C12 L S L F F i r , no n T 6 / O / O al e 9 u 但只要 O TU设置了光关联后 ,就 始终会发光 ,其发 出
解答 :告警 ②是否被屏蔽取决于设备上光关联是如 何做的 。 如果光关联 是用双 O U直 通 ( DU-O T O ,TUD 0 3
— O UD3 )分别实现的 ,则告警不会被屏蔽 。注意 , T 0 这两种关联 对于传输信号是等同的 ,只是 告警的报告会
有不 同。
时,其发信激光器就会关闭, 并会有 L srS uo 事 ae h tf

ALCATEL告警手册V2完全版(无线)

ALCATEL告警手册V2完全版(无线)

前言由于ALCATEL公司提供的告警资料一般都是英文,而且其编排顺序是按照流水号编排的,没有逻辑层面的思路。

所以我们编写这套资料,一个对卡特的告警词典起到一个汉化的作用;另一方面,通过对告警资料的重新分析梳理,使之条理清晰,结构严谨。

本手册按章节结构编撰,在每一小类告警中,按照级别排列。

最后给出了告警规范以及每条告警出现频次的经验值。

本手册所给出的处理流程均为厂商规定的标准处理流程,在实际工作中可能也并不完全按照操作,所以同时也给出了或是经验操作建议,或是提醒,用符号“ ”标示。

根据全省设备分布情况和技术进步角度,本手册摒弃了G1BSC的告警,仅仅包括G2BSC、G2BTS、和EVOLIUM BTWS。

目录第一部分、卡特无线告警基础知识 (2)第二部分:BSC核心故障 (3)§1、PROCESSOR类告警 (4)§2、X25类告警 (5)§3、BSC电源类告警 (7)§4、SWITCH类告警 (7)§5、N7类告警 (8)§6、TRUNK类告警 (9)§7、TELECOM类告警 (11)§8、BSC总体类告警 (12)§9、SWTICH G2类告警 (15)§10、BSC CLOCK类告警 (17)§11、BSC BROADCAST-BUS类告警 (19)§12、BSC ADAPT类告警 (21)第三部分:BTS核心告警 (22)§1、CELL类告警 (22)§2、BTS类告警 (24)§3、RSL类告警 (26)§4、OML类告警 (27)第四部分、卡特无线告警规范 (29)第一部分、卡特无线告警基础知识一、告警的级别:在alcatel系统中定义了告警的五个级别,分别是,critical,major,minor,warning,indeterminate,我们映射成四个结别,分别是,严重、主要、次要、其它,他们的默认含义界定如下:critical(严重):一个非常重要的故障,需要立即采取行动纠正清除故障。

常见(重要)告警说明

常见(重要)告警说明

常见(重要)告警说明一.常见(重要)告警列表:目录索引:1.1 PROCESSOR[33] ACCESS-FAIL[3] (3)1.2 BSC-ADAPT[73]EQUIPMENT-FAULT[128]: (4)1.3 BSC-CLOCK[52] LOSS-OF-SYSTEM-CLK-A[3]: (5)1.4 BSC-CLOCK[52] LOSS-OF-SYSTEM-CLK-B[4]: (5)1.5 BSC-CLOCK[52] BSC-RUN-ON-LOCAL-CLK[6]: (6)2.1 PROCESSOR[33] RESTART[0]: (7)2.2 PROCESSOR[33] RESET[1]: (7)2.3 PROCESSOR[33] SDCCH-OVRL-BSC[9]: (8)2.4 PROCESSOR[33] TAKEOVER[7]: (8)2.5 PROCESSOR[33] RELC-OV[4]: (9)2.6 GOLBAL-BSC[47] SCCP-NOT-A V AIL[1]: (10)3.1 N7[35] LNK-REP[0]: (11)3.2 TSC-TRUNK [66] TWO-MB-MISSING[50]: (11)3.3 TSC-TRUNK [66] AIS-2-MB[66]: (11)3.4 TSC-TRUNK [66] FRAME-ALIGNMENT[81]: (11)3.5 TSC-TRUNK [66] BER-10E-3[99]: (12)3.6 TSC-TRUNK [66] BER-10E-4[100]: (12)3.7 TSC-TRUNK [66] BER-10E-6[102]: (12)3.8 TSC-TRUNK [66] FAR-END-ALARM[176]: (12)4.1 BSS BVCSig is broken on: (13)4.2 BSS GSL is broken on(GSL out): (14)5.1 CELL[43] LOSS-OF-BCCH[0]: (16)5.2 CELL[43] LOSS-OF-ALL-CHAN[3]: (17)6.1 CELL[43] LOSS-OF-TCH[2]: (18)7.1 RTCH_fail_rate (18)8.1 BTS-EXTERNAL[9] bts-external-2[2] (19)8.2 BTS-EXTERNAL[9] bts-external-2[2]mbo (19)8.3 ENVIR[5] MAINS-AL[20] (19)9.1 BTS-EXTERNAL[9] bts-external-3[3] (19)9.2 BTS-EXTERNAL[9] bts-external-3[3]mbo (19)10.1 At least one temperature sensor has detected a T > 65C: (20)10.2 CNVR: disjunction due to output voltage problem on converter: (20)10.3 2.1V: no more redondancy of GPU boards: (21)二.常见(重要)告警祥解: BSC设备方面的常见告警:1.1 PROCESSOR[33] ACCESS-FAIL[3]1.2 BSC-ADAPT[73]EQUIPMENT-FAULT[128]:1.3 BSC-CLOCK[52] LOSS-OF-SYSTEM-CLK-A[3]:1.4 BSC-CLOCK[52] LOSS-OF-SYSTEM-CLK-B[4]:1.5 BSC-CLOCK[52] BSC-RUN-ON-LOCAL-CLK[6]:BSC负荷方面的常见告警:2.1 PROCESSOR[33] RESTART[0]:2.2 PROCESSOR[33] RESET[1]:2.3 PROCESSOR[33] SDCCH-OVRL-BSC[9]:2.4 PROCESSOR[33] TAKEOVER[7]:2.5 PROCESSOR[33] RELC-OV[4]:2.6 GOLBAL-BSC[47] SCCP-NOT-A V AIL[1]:BSC传输方面的常见告警:3.1 N7[35] LNK-REP[0]:3.2 TSC-TRUNK [66] TWO-MB-MISSING[50]:3.3 TSC-TRUNK [66] AIS-2-MB[66]:3.4 TSC-TRUNK [66] FRAME-ALIGNMENT[81]:3.5 TSC-TRUNK [66] BER-10E-3[99]:3.6 TSC-TRUNK [66] BER-10E-4[100]:3.7 TSC-TRUNK [66] BER-10E-6[102]:3.8 TSC-TRUNK [66] FAR-END-ALARM[176]:GRPS方面的常见告警:4.1 BSS BVCSig is broken on:4.2 BSS GSL is broken on(GSL out):4.3 LapDLink disabled:小区退服的关键告警:5.1 CELL[43] LOSS-OF-BCCH[0]:5.2 CELL[43] LOSS-OF-ALL-CHAN[3]:基站载频退服关键告警:6.1 CELL[43] LOSS-OF-TCH[2]:小区分配失败7.1 RTCH_fail_rate基站交流断电外部告警:8.1 BTS-EXTERNAL[9] bts-external-2[2] 8.2 BTS-EXTERNAL[9] bts-external-2[2]mbo 8.3 ENVIR[5] MAINS-AL[20]基站直流低电压外部告警:9.1 BTS-EXTERNAL[9] bts-external-3[3] 9.2 BTS-EXTERNAL[9] bts-external-3[3]mboMFS重要外部告警10.1 At least one temperature sensor has detected a T > 65C:10.2 CNVR: disjunction due to output voltage problem on converter:10.3 2.1V: no more redondancy of GPU boards:。

2M告警环回示意

2M告警环回示意

用户A
网元1
网元2
网元3
网元4
网元5
网元6
用户B
环一
环二
环三
2020/2/20
常见告警的判断五:无任何告警可能原因
• 原因1:在华为网管常出现此类故障现象,因该厂商不 支持对EXC、LOF、DF等告警的监控。
• 原因2:传输通路吊死,在环回并还原通路后用户即可 恢复。
2020/2/20
2020/2/20
常见告警的判断四:其他告警
此时在第一次出现LOF、EXC等告警的地方进行环回, 如下图所示的两次环回,分别环给用户A、B,如用户A、B 的告警均消失,则可定位故障段落。
故障段落
LOF、EXC
LOF、EXC
LOF、EXC
用户A
用户B
DF
2020/2/20
环一
DF
环二
DF
环三
DF
常见告警的判断四:其他告警可能原因
传输设备
2M信号
示意图说明 光路信号
环一
环二
环三
用户设备
2020/2/20
2M告警检测点
华为厂商环回说明 内环回=对端环回
环一
环二
环三
外环回=本端环回
2020/2/20
环一
环二
环三
朗讯厂商环回说明 外环回=对端环回
环一
环二
环三
内环回=本端环回
2020/2/20
环一
环二
环三
其他
实际中2M转接电路有可能为不同厂商,由于华为厂商 与朗讯厂商的内、外环回概念恰恰相反,为了便于介绍,以 下只按本端、远端环回来说明环回方向,实际进行环回操作 时,应根据不同厂商灵活运用。
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

CRITICAL 1207-STMKJ-1660EQUIPMENTMAJOR 1207-STMKJ-1660/r01sr1sl16/port#007-#01-Au4P-Tmi COMMUNICATIONS MINOR 1207-STMKJ-1660/r01sr1sl02/port#006-#01-Au4P-TMe COMMUNICATIONS MINOR 1005-LDWC-1678/r01sr3/board#11EQUIPMENT MINOR 1005-LDWC-1678/r01sr3/board#10EQUIPMENT MINOR 1005-LDWC-1678/r01sr3/board#01EQUIPMENTMAJOR 1005-LDWC-1678/r01sr4sl08/port#01-#0002-rsDC COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3/board#10COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl08/port#01-#0001-msDC COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl12/port#01-MsTTPCOMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl02/port#002-#01-Au4P-TMe COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl12/port#01-MsTTP COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl12/port#01-RsTTP COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl12/port#01-OpSCOMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl12/port#01-T0SyncPu COMMUNICATIONS MINOR 1005-LDWC-1678/r01sr3sl12/port#01-T0SyncPu COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl08/port#01-MsTTP COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl08/port#01-MsTTP COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl08/port#01-MsTTPCOMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl24/port#001-#01-Au4P-TMe COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl08/port#008-#01-Au4P-TMe COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl04/port#06-#01-p12Mon_vc12COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl19/port#01-#1-e1MonCTP COMMUNICATIONS MINOR 1207-STMKJ-1660/timingGenerator COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1/board#40EQUIPMENT WARNING 1207-STMKJ-1660EQUIPMENTMAJOR 1207-STMKJ-1660/r01sr1sl23/port#05-#3-6-2-Tu12COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl23/port#02-#01-Vc4COMMUNICATIONS WARNING 1207-STMKJ-1660EQUIPMENT MINOR 1207-STMKJ-1660/r01sr2/board#01EQUIPMENTMAJOR 1207-STMKJ-1660/r01sr1sl25/port#001-RsTTP-PMTR15COMMUNICATIONS WARNING 1207-STMKJ-1660/ExtInPt#9ENVIRONMENTAL MAJOR 1207-STMKJ-1660/r01sr1sl34/port#001-OpSCOMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl18/port#01-OpRsCTP COMMUNICATIONS MINOR 1207-STMKJ-1660EQUIPMENTMAJOR 1207-STMKJ-1660/r01sr1sl14/port#003-ElS COMMUNICATIONS WARNING 1207-STMKJ-1660/r01sr2/board#02EQUIPMENTMAJOR 1005-LDWC-1678/r01sr3sl03/port#04-#01-Au4P-16c COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl03/port#01-RsTTPCOMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl03/port#05-#01-Au4P-16c COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl19/port#01-#01-Vc12COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl28/port#001-#02-Au4P COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl14/port#001-ElRsCTP COMMUNICATIONS MINOR 1207-STMKJ-1660/r01sr1sl16/port#01-#01-Vc12COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl23/port#01-#01-Vc4COMMUNICATIONS MAJOR 1005-LDWC-1678/r01sr3sl03/port#05-#01-Au4P-16c-TMi COMMUNICATIONS MINOR 1005-LDWC-1678/r01sr3sl02/port#10-#01-Au4P-16c-TMiCOMMUNICATIONS WARNING 1207-STMKJ-1660/r01sr1sl16/port#008-#01-Au4P-TMi COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl01/port#09-#01-Vc12COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl24/port#001-#01-Au4P-TMi COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl23/port#01-#01-Vc4COMMUNICATIONS MINOR 1207-STMKJ-1660/r01sr1sl23/port#04-#01-Vc4COMMUNICATIONS MINOR 1207-STMKJ-1660/r01sr1sl38/port#001-OpS COMMUNICATIONS MINOR1207-STMKJ-1660/r01sr1/board#38EQUIPMENTMINOR 1207-STMKJ-1660/r01sr1sl38/port#001-RsTTPCOMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl23/port#04-#01-Vc4COMMUNICATIONS MAJOR 1207-STMKJ-1660/2MbpsT6#ACOMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl23/port#01-#01-Vc4COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl01/port#01-#01-p12Mon_vc12COMMUNICATIONS MAJOR 1207-STMKJ-1660/r01sr1sl27/port#001-#01-Au4P-TMi COMMUNICATIONS WARNING 1005-LDWC-1678/r01sr3sl03/daughter#07EQUIPMENTMAJOR 1207-STMKJ-1660/r01sr1sl15/port#002-#01-Au4P-TCMi COMMUNICATIONS MAJOR1207-STMKJ-1660/r01sr1sl15/port#002-#01-Au4P-TCMeCOMMUNICATIONSResource Isolation网元脱管Unequipped155M通道业务未装载告警Degraded Signal155M通道信号劣化告警Lan Failure1678设备11槽位矩阵盘以太网连接失败Lan Failure1678设备10槽位矩阵盘以太网连接失败No RTC Synchronization1678设备与时钟(RTC)服务器没有同步Communications Subsystem Failure再生段通信子系统连接失效Communications Subsystem Failure1678矩阵盘与监控盘间的通信子系统连接失效Communications Subsystem Failure复用段通信子系统连接失效Server Signal Failure复用段服务信号失效Unequipped155M通道业务未装载告警Remote Defect Indication复用段远端接收失效指示Server Signal Failure复用段服务信号失效Loss Of Signal光口接收信号丢失,需要登录相关设备端口才能确认接口速率Server Signal Failure时钟源服务信号失效Frequency Offset时钟源频偏,时钟源不可用AIS复用段全“1”信号指示,需要登录相关设备端口才能确认接口速率Excessive BER复用段接收信号误码超限,需要登录相关设备端口才能确认接口速率Degraded Signal复用段接收信号劣化告警,需要登录相关设备端口才能确认接口速率Excessive BER155M通道误码超限Server Signal Failure155M通道服务信号失效AIS2M 通道全“1”信号指示AIS2M 通道全“1”信号指示Loss Of Timing Sources设备时钟源丢失Replaceable Unit Problem机盘故障MIB backup misaligned设备与网管的配置数据未同步Loss Of Pointer2M通道,TU12指针丢失Server Signal Failure vc4告警通道全“1”告警Inside Failure设备内部连接失败Cooling Fan Failure风扇失败告警Unavailable性能不可用Housekeeping Alarm设备外部引入告警Underlying Resource Unavailable 端口底层资源部可用,一般是由于机盘故障引起,需要登录相关设备端口才能确认接口速率Loss Of Frame光口接收信号帧丢失,需要登录相关设备端口才能确认接口速率Fuse Failure设备备用电源失效Loss Of Signal155M电口信号丢失Unconfigured Equipment Present未配置的机盘存在AIS 2.5G 通道全“1”信号指示Trace Identifier Mismatch再生段跟踪字节不匹配Loss Of Pointer 2.5G通道,指针丢失Server Signal Failure2M通道服务信号失效Loss Of Pointer155M通道,指针丢失Loss Of Frame155M电口接收信号帧丢失Degraded Signal2M通道信号劣化告警Payload Type Mismatch155M通道负荷类型不匹配Server Signal Failure 2.5G通道服务信号失效Degraded Signal 2.5G通道信号劣化告警Remote Defect Indication155M远端接收失效指示Trace Identifier Mismatch vc12跟踪字节不匹配AIS155M 通道全“1”信号指示Unequipped155M通道业务未装载告警Degraded Signal155M高价通道信号劣化告警Transmitter Failure光口发光失效,需要登录相关设备端口才能确认接口速率Replaceable Unit Missing机盘故障或机盘不存在Underlying Resource Unavailable 端口底层资源部可用,一般是由于机盘故障引起,需要登录相关设备端口才能确认接口速率Excessive BER155M高价通道误码超限Loss Of Signal设备外部引入2M bit时钟源信号丢失Trace Identifier Mismatch vc4跟踪字节不匹配Payload Type Mismatch2M通道负荷类型不匹配Excessive BER155M通道误码超限Replaceable Unit Type Mismatch机盘类型不匹配Server Signal Failure155M通道服务信号失效Server Signal Failure155M通道服务信号失效重启相关1678设备的DCR,或检查网管通道从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务软重启相关1678设备的相关的矩阵盘(需要ALCATEL工程师电话支持)软重启相关1678设备的相关的矩阵盘(需要ALCATEL工程师电话支持)非紧急故障重启相关1678设备的DCR软重启相关1678设备的相关的矩阵盘(需要ALCATEL工程师电话支持)重启相关1678设备的DCR从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换检查设备时钟源检查设备时钟源如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务检查设备时钟源更换机盘非紧急故障从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务检查设备内部机盘连接,更换工作异常的机盘非紧急故障从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换非紧急故障从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换现场检查设备主备电压工作状态从资管系统查看该端口有否加栽业务非紧急故障从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换更换机盘从资管系统查看该端口有否加栽业务;如是2.5G或10G速率光口,请查看有否保护系统倒换从资管系统查看该端口有否加栽业务现场检查设备时钟源从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务更换机盘从资管系统查看该端口有否加栽业务从资管系统查看该端口有否加栽业务。