WFD-600RF热风炉说明书
合集下载
相关主题
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
01050014
热风炉红外测温仪使用说明书
□ WFD-600RF—L 立式 □ WFD-600RF—W 卧式
VER 7.8
北京市科海龙华工业自动化仪器有限公司
http://www.kehaiinst.com E-mail:kehai@ kehaiinst.com
目录
一、概述·······················································································(2) 二、主要特点···············································································(2) 三、技术指标···············································································(2) 四、工作原理与结构特征···························································(3) 五、设计选型···············································································(5) 六、安装和调试···········································································(6) 七、测温探头使用方法·······························································(8) 八、检定方法···············································································(9) 九、维护·······················································································(10) 十、常见故障及排除方法···························································(10) 十一、使用注意事项···································································(10) 十二、售后服务···········································································(11) 十三、订货须知···········································································(11) 十四、装箱清单···········································································(11) 附件:信号处理显示器·······························································(12) 附页:热风炉红外测温仪安装炉体法兰盘焊装示意图 ··········(16)
-2-
四、工作原理与结构特征
1.辐射测温原理: 根据普郎克公式,温度为 T(K)的物体所辐射的波长为 λ 的辐射能量:
W(λT )
=
ε (λT )
C1 ⋅ λ−5 e C2 −1
λT
式中:W(λT)— 为黑体单位面积在温度 T 时,在 λ 波长处的辐射能量,W/m2.µm
ε(λT)— 物体的发射率
三、技术指标
1.测量范围:700~1500℃(用户在此温度范围内选择温度段) 2.标定精度:±1%(测量温度的上限)(黑体标定) 3.重 复 性:±0.5%±1℃ (测量温度的上限)(黑体标定) 4.距离系数:L/D=100 L—探头到目标距离,D—测斑直径(成象物距 L=1500mm) 5.工作波段:0.7~1.0µm(或 1.0~1.7µm) 6.响应时间:1 秒(根据现场条件可调整) 7.发 射 率:0.1~1.0(连续可调) 8.温度分辨率:1℃ 9.显 示 值:4 位 LED 发光数码管显示有平均值、峰值、实时值等三种显示方式 10.使用环境:温度≤70℃;湿度≤85%RH 11.供电电源:~220V±10%、50HZ、20W
4.热风炉测温系统总接线图
电源箱接线
热风炉测温系统总接线图 -7-
七、测温探头使用方法
1.调试 调试前保护窗先通电 10 分钟,然后开启手动阀门,调节调角器角度,经瞄准系统从目镜中 瞄准目标 w,可看出被测目标清晰的图像,并使探测器内的十字线中心瞄准被测目标物体中心。 要求被测目标的物体像斑比圆圈大,以保证被测目标物体充满视场,装好防尘罩。
如果用户希望在屏幕上看到测点附近的实景,可以订购摄像附件。
二、主要特点
1.具有光学瞄准系统,采用不调焦折透式,加分划板瞄准。可以方便地找到被测目标及其对中。 2.具有实时值、平均值、峰值和自动环境温度补偿。 3.多种系统组成方案,适应不同现场的需要。 4.探测部分加有防结雾窗口,避免红外能量衰减。 5.探测部分加有不锈钢阀门,便于用户封闭炉体、维护红外探头和清洁窗口。 6.独特的调角和机械部件,可方便地校正因窥视孔位置形变引起的瞄准偏移。 7.红外测温探头工作在短波段,对窗口污染有较好的适应性,窗口透过率降低 36%,测温 示值仅降低 4%。
-4-
4.电源箱(必配) 1)外形如下(注:根据不同的现场环境或用户特殊要求,外形及尺寸可能有变化。)
2)功能 WFD-RFBX 供电为 AC220V,它为测温探头提供 DC24V 工作电源,为保护窗口提供 AC24-36V 加热电源。
五、设计选型
1.选型 一般情况,不需要空气或氮气吹扫。如果用户供气方便,也可以加吹扫,可使窗口清洁保持 更长时间,减少维护工作量。 如果要求测温精度更高,大大延长窗口清洁周期,可以选择双色测温探头。一般情况推荐使 用单(色)波段测温仪,以降低成本。绝大多数情况它都能满足用户的需求。如果用户希望在屏 幕上看到测点附近的实景,可以订购摄像附件。 2.安装方式 热风炉红外测温仪有两种安装方式:立式型安装和卧式安装。 卧式安装存在通道积水问题。为了避免这个问题,安装时就要抬高后部保持 2-3°的倾角并开 较大孔,配置较大口径的法兰盘,如 DN80 法兰盘。 立式型号:WFD-600RF-L 卧式型号:WFD-600RF-W 3.布线方案 从热风炉炉顶现场到控制室的布线方案有二种:二芯线、六芯线 (1)如果热风炉炉顶能提供 AC220V 电源则只须铺设二芯电缆。 WFD-RFBX 型电源箱放置于现场,它为测温探头提供 DC24V 电源,为保护窗口提供 AC24-36V 的加热电源。这两种电源线都较短,出厂时已配备好。因此,只需从炉顶到控制室铺 设一条二芯电缆传输 4-20mA。也可使用原有的工业偶导线。
按图二自下至上依次连接,确保密封良好。安装时手动阀门保持关闭,完成全部安装后再通 电加热保护窗 10 分钟。10 分钟后开启手动闸门,再调节调角器,观察探测头目镜,使探头瞄准 被测点。
3.电源箱的安装(必配) WFD-RFBX 电源箱安装在测温探头附近,通过专用电缆与探头连接。 箱内端子排列及说明:
六、安装和调试
1.安装方式 针对不同的应用现场和用户的不同要求有不同的几种安装方式,如下图所示。
卧式型安装示意图
立式型安装示意图 多数热风炉用垂直安装方式,通过测温探头瞄准孔观察和通过调角器调节,使测温探头瞄准 到格子砖上,要保持分划板小圈在系统内径的中心。落在格子砖上的测斑通常可以覆盖若干格子 砖小孔,因此,不必考虑分划板小圈是落在格子砖小孔内或小孔外,只要保持在系统内径中心即 可。由于热风炉拱顶会随时间发生变形,可定期调整调角器加以修正。 有些热风炉要求水平安装。水平安装最好把手动阀门放在前端,与窥视管相接,调角器后移
-5-
(2)如果热风炉炉顶不能提供 AC220V,则需铺设六芯电缆 WFD-RFBX 型电源箱放置于控制室。由它提供的 DC24V 电源和窗口电源 AC24-36V 以及探 头输出的 4-20mA 信号共六根线可共用一根六芯电缆。单根线铜芯面积须大于 1mm2。 3.选配信号处理显示器 如果需要热风炉红外测温仪输出 S 分度或 B 分度 mV 信号,则须选配 WFD-600RF-X 型信号 处理显示器。 详见附件。
-6-
与保护窗口相接。同时系统安装时要抬高后部与水平保持 2-3°的wk.baidu.com角。这样可以避免系统内部存 有炉内热风形成的冷凝积水。
本系统也可以用于风道测温,在风道测温中,调角器和手动阀门的前后次序没有明确要求。 内部积灰、积水的可能性比较小,安装位置垂直、水平或其它角度均可。如果现场存在积灰、积 水,应选择倾斜方式安装。 2.探测系统的安装
C1 — 第一辐射常数 C1=3.7418×10-16 W.m2
C2 — 第二辐射常数 C2 =1.4388×10-2 m.K
λ — 波长、µm
T — 热力学温度 K (T=273.15+t,t 为摄氏温度值)
∫ 本仪表选用光电探测器件,它的 λ=0.7-1.1µm,所得到辐射功率为:
W=
1.1
0.7 W(λT
)
dλ
。
测得被测目标的辐射能量,就可以求得被测目标的温度。ε(λT)为发射率,它是波长、温度、
物体种类、表面状态等诸因素的复杂函数。仪表通常由 ε(λT)=1 的黑体炉标准装置标定,在测
量具体对象温度时,用修正发射率办法,减少测量误差。
2.红外测温探头光路图如下:
物镜
分光镜 分划板
目镜
探测器
红外探头光路图 被测目标的辐射能量透过物镜投射到分光镜上,其可见光透过分划板到达目镜,用以观察被 测目标。红外辐射能量经分光镜反射后会聚到探测器件(光电器件)灵敏面上。探测器件将入射 的光信号转化为电信号,其输出被前置放大电路放大。
-1-
一、概述
热风炉红外测温仪是一种智能化高精度非接触式仪表。它适用于加热炉、热风炉拱顶和风道 的温度测量,通过被测物体的红外辐射能量来确定物体的温度。仪表显示性能稳定、响应速度快、 操作简单、安装与调整方便,是理想的非接触式测温仪。
本系统探测部分必须保持与炉体密封安装,使热风不致外泄,不需水冷和风冷也能保证探测 部分正常工作,不会发生过热现象。由于热风不外泄,光学窗口也可保持相对清洁。如果用户现 场可提供清洁压缩空气或氮气,可以引入探测部份对光学窗口吹扫,此项吹扫不是为了冷却探测 部分,而是延长窗口清洁时间,减轻维护工作量。
物体像斑位置图
1.设定参数方法 测温探头上有三个按键:e、c和f,利用这三个按键可设定参数。 探头在工作状态下,连接几下e键,即可设定参数。此时,显示窗显示的 4 位数字中有一位 在闪动,按c键可使该位数字循环加 1,按键说明如下: e键:参数序号键 按一下e键,存储当前设定数值,并显示下一参数序号“H XX”,2 秒钟后再显示该序号参 数值。 c键:循环加 1 键 按一下e键,当前闪动数字循环加 1。 f键:设定位选择键 按一下f键,当前设定位循环右移 1 位。
-3-
3.红外探测系统部分 1)外形见图二
立式安装示意图 2)探测器内具有光学瞄准系统,通过物镜,在目镜上可以很容易对准被测目标,测量时必 须保证目标在分划板上的象比圆圈大,即保障被测目标充满现场。 3)探测器中装有接收红外辐射的探测器件,同时装有温度补偿电路,对环境温度影响进行 补偿。 4)探测器下部有防雾保护窗、手动阀门、调角器和窥视管。窥视管底盘上法兰有四个固定 孔,将探测器系统牢固地固定在拱顶上。 5)窗口电源为 AC 24-36V 1A。连接电线铜芯面积大于 1mm2 或导线总电阻不超过 2Ω。 6)测温探头输出线性化 4-20mA 信号。 7) 系统必须配置 WFD-RFBX 型电源箱。它为测温探头提供 DC24V 电源,为保护窗口提供 AC 24-36V 的加热电源。
热风炉红外测温仪使用说明书
□ WFD-600RF—L 立式 □ WFD-600RF—W 卧式
VER 7.8
北京市科海龙华工业自动化仪器有限公司
http://www.kehaiinst.com E-mail:kehai@ kehaiinst.com
目录
一、概述·······················································································(2) 二、主要特点···············································································(2) 三、技术指标···············································································(2) 四、工作原理与结构特征···························································(3) 五、设计选型···············································································(5) 六、安装和调试···········································································(6) 七、测温探头使用方法·······························································(8) 八、检定方法···············································································(9) 九、维护·······················································································(10) 十、常见故障及排除方法···························································(10) 十一、使用注意事项···································································(10) 十二、售后服务···········································································(11) 十三、订货须知···········································································(11) 十四、装箱清单···········································································(11) 附件:信号处理显示器·······························································(12) 附页:热风炉红外测温仪安装炉体法兰盘焊装示意图 ··········(16)
-2-
四、工作原理与结构特征
1.辐射测温原理: 根据普郎克公式,温度为 T(K)的物体所辐射的波长为 λ 的辐射能量:
W(λT )
=
ε (λT )
C1 ⋅ λ−5 e C2 −1
λT
式中:W(λT)— 为黑体单位面积在温度 T 时,在 λ 波长处的辐射能量,W/m2.µm
ε(λT)— 物体的发射率
三、技术指标
1.测量范围:700~1500℃(用户在此温度范围内选择温度段) 2.标定精度:±1%(测量温度的上限)(黑体标定) 3.重 复 性:±0.5%±1℃ (测量温度的上限)(黑体标定) 4.距离系数:L/D=100 L—探头到目标距离,D—测斑直径(成象物距 L=1500mm) 5.工作波段:0.7~1.0µm(或 1.0~1.7µm) 6.响应时间:1 秒(根据现场条件可调整) 7.发 射 率:0.1~1.0(连续可调) 8.温度分辨率:1℃ 9.显 示 值:4 位 LED 发光数码管显示有平均值、峰值、实时值等三种显示方式 10.使用环境:温度≤70℃;湿度≤85%RH 11.供电电源:~220V±10%、50HZ、20W
4.热风炉测温系统总接线图
电源箱接线
热风炉测温系统总接线图 -7-
七、测温探头使用方法
1.调试 调试前保护窗先通电 10 分钟,然后开启手动阀门,调节调角器角度,经瞄准系统从目镜中 瞄准目标 w,可看出被测目标清晰的图像,并使探测器内的十字线中心瞄准被测目标物体中心。 要求被测目标的物体像斑比圆圈大,以保证被测目标物体充满视场,装好防尘罩。
如果用户希望在屏幕上看到测点附近的实景,可以订购摄像附件。
二、主要特点
1.具有光学瞄准系统,采用不调焦折透式,加分划板瞄准。可以方便地找到被测目标及其对中。 2.具有实时值、平均值、峰值和自动环境温度补偿。 3.多种系统组成方案,适应不同现场的需要。 4.探测部分加有防结雾窗口,避免红外能量衰减。 5.探测部分加有不锈钢阀门,便于用户封闭炉体、维护红外探头和清洁窗口。 6.独特的调角和机械部件,可方便地校正因窥视孔位置形变引起的瞄准偏移。 7.红外测温探头工作在短波段,对窗口污染有较好的适应性,窗口透过率降低 36%,测温 示值仅降低 4%。
-4-
4.电源箱(必配) 1)外形如下(注:根据不同的现场环境或用户特殊要求,外形及尺寸可能有变化。)
2)功能 WFD-RFBX 供电为 AC220V,它为测温探头提供 DC24V 工作电源,为保护窗口提供 AC24-36V 加热电源。
五、设计选型
1.选型 一般情况,不需要空气或氮气吹扫。如果用户供气方便,也可以加吹扫,可使窗口清洁保持 更长时间,减少维护工作量。 如果要求测温精度更高,大大延长窗口清洁周期,可以选择双色测温探头。一般情况推荐使 用单(色)波段测温仪,以降低成本。绝大多数情况它都能满足用户的需求。如果用户希望在屏 幕上看到测点附近的实景,可以订购摄像附件。 2.安装方式 热风炉红外测温仪有两种安装方式:立式型安装和卧式安装。 卧式安装存在通道积水问题。为了避免这个问题,安装时就要抬高后部保持 2-3°的倾角并开 较大孔,配置较大口径的法兰盘,如 DN80 法兰盘。 立式型号:WFD-600RF-L 卧式型号:WFD-600RF-W 3.布线方案 从热风炉炉顶现场到控制室的布线方案有二种:二芯线、六芯线 (1)如果热风炉炉顶能提供 AC220V 电源则只须铺设二芯电缆。 WFD-RFBX 型电源箱放置于现场,它为测温探头提供 DC24V 电源,为保护窗口提供 AC24-36V 的加热电源。这两种电源线都较短,出厂时已配备好。因此,只需从炉顶到控制室铺 设一条二芯电缆传输 4-20mA。也可使用原有的工业偶导线。
按图二自下至上依次连接,确保密封良好。安装时手动阀门保持关闭,完成全部安装后再通 电加热保护窗 10 分钟。10 分钟后开启手动闸门,再调节调角器,观察探测头目镜,使探头瞄准 被测点。
3.电源箱的安装(必配) WFD-RFBX 电源箱安装在测温探头附近,通过专用电缆与探头连接。 箱内端子排列及说明:
六、安装和调试
1.安装方式 针对不同的应用现场和用户的不同要求有不同的几种安装方式,如下图所示。
卧式型安装示意图
立式型安装示意图 多数热风炉用垂直安装方式,通过测温探头瞄准孔观察和通过调角器调节,使测温探头瞄准 到格子砖上,要保持分划板小圈在系统内径的中心。落在格子砖上的测斑通常可以覆盖若干格子 砖小孔,因此,不必考虑分划板小圈是落在格子砖小孔内或小孔外,只要保持在系统内径中心即 可。由于热风炉拱顶会随时间发生变形,可定期调整调角器加以修正。 有些热风炉要求水平安装。水平安装最好把手动阀门放在前端,与窥视管相接,调角器后移
-5-
(2)如果热风炉炉顶不能提供 AC220V,则需铺设六芯电缆 WFD-RFBX 型电源箱放置于控制室。由它提供的 DC24V 电源和窗口电源 AC24-36V 以及探 头输出的 4-20mA 信号共六根线可共用一根六芯电缆。单根线铜芯面积须大于 1mm2。 3.选配信号处理显示器 如果需要热风炉红外测温仪输出 S 分度或 B 分度 mV 信号,则须选配 WFD-600RF-X 型信号 处理显示器。 详见附件。
-6-
与保护窗口相接。同时系统安装时要抬高后部与水平保持 2-3°的wk.baidu.com角。这样可以避免系统内部存 有炉内热风形成的冷凝积水。
本系统也可以用于风道测温,在风道测温中,调角器和手动阀门的前后次序没有明确要求。 内部积灰、积水的可能性比较小,安装位置垂直、水平或其它角度均可。如果现场存在积灰、积 水,应选择倾斜方式安装。 2.探测系统的安装
C1 — 第一辐射常数 C1=3.7418×10-16 W.m2
C2 — 第二辐射常数 C2 =1.4388×10-2 m.K
λ — 波长、µm
T — 热力学温度 K (T=273.15+t,t 为摄氏温度值)
∫ 本仪表选用光电探测器件,它的 λ=0.7-1.1µm,所得到辐射功率为:
W=
1.1
0.7 W(λT
)
dλ
。
测得被测目标的辐射能量,就可以求得被测目标的温度。ε(λT)为发射率,它是波长、温度、
物体种类、表面状态等诸因素的复杂函数。仪表通常由 ε(λT)=1 的黑体炉标准装置标定,在测
量具体对象温度时,用修正发射率办法,减少测量误差。
2.红外测温探头光路图如下:
物镜
分光镜 分划板
目镜
探测器
红外探头光路图 被测目标的辐射能量透过物镜投射到分光镜上,其可见光透过分划板到达目镜,用以观察被 测目标。红外辐射能量经分光镜反射后会聚到探测器件(光电器件)灵敏面上。探测器件将入射 的光信号转化为电信号,其输出被前置放大电路放大。
-1-
一、概述
热风炉红外测温仪是一种智能化高精度非接触式仪表。它适用于加热炉、热风炉拱顶和风道 的温度测量,通过被测物体的红外辐射能量来确定物体的温度。仪表显示性能稳定、响应速度快、 操作简单、安装与调整方便,是理想的非接触式测温仪。
本系统探测部分必须保持与炉体密封安装,使热风不致外泄,不需水冷和风冷也能保证探测 部分正常工作,不会发生过热现象。由于热风不外泄,光学窗口也可保持相对清洁。如果用户现 场可提供清洁压缩空气或氮气,可以引入探测部份对光学窗口吹扫,此项吹扫不是为了冷却探测 部分,而是延长窗口清洁时间,减轻维护工作量。
物体像斑位置图
1.设定参数方法 测温探头上有三个按键:e、c和f,利用这三个按键可设定参数。 探头在工作状态下,连接几下e键,即可设定参数。此时,显示窗显示的 4 位数字中有一位 在闪动,按c键可使该位数字循环加 1,按键说明如下: e键:参数序号键 按一下e键,存储当前设定数值,并显示下一参数序号“H XX”,2 秒钟后再显示该序号参 数值。 c键:循环加 1 键 按一下e键,当前闪动数字循环加 1。 f键:设定位选择键 按一下f键,当前设定位循环右移 1 位。
-3-
3.红外探测系统部分 1)外形见图二
立式安装示意图 2)探测器内具有光学瞄准系统,通过物镜,在目镜上可以很容易对准被测目标,测量时必 须保证目标在分划板上的象比圆圈大,即保障被测目标充满现场。 3)探测器中装有接收红外辐射的探测器件,同时装有温度补偿电路,对环境温度影响进行 补偿。 4)探测器下部有防雾保护窗、手动阀门、调角器和窥视管。窥视管底盘上法兰有四个固定 孔,将探测器系统牢固地固定在拱顶上。 5)窗口电源为 AC 24-36V 1A。连接电线铜芯面积大于 1mm2 或导线总电阻不超过 2Ω。 6)测温探头输出线性化 4-20mA 信号。 7) 系统必须配置 WFD-RFBX 型电源箱。它为测温探头提供 DC24V 电源,为保护窗口提供 AC 24-36V 的加热电源。