丹佛斯电磁阀

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Data sheet

Solenoid valves type EVRA 3 ® 40

Introduction

EVRA is a direct or servo operated solenoid valve for liquid, suction and hot gas lines with ammonia or fluorinated refrigerants.

EVRA valves are supplied complete or as

separate components, i.e. valve body, coil and flanges can be ordered separately.

Approvals

DnV, Det norske Veritas, Norway DSRK, Deutsche Schiffs-Revision und -Klassifikation, Germany P Polski Rejestr Statków, Poland W FIMKO, Finland

MRS, Maritime Register of Shipping

Technical data

Refrigerants

R 717 (NH 3) R 22, R 134a, R 404A and other fluorinated refrigerants

Temperature of medium

-40 ® +105°C with 10 W or 12 W coil.Max. 130°C during defrosting.

Ambient temperature and enclosure for coil

See "Coils for solenoid valves", RD.3J.B2.04.

1)The k v

value is the water flow in m 3/h at a pressure drop across valve of 1 bar, r = 1000 kg/m 3.2)MOPD for media in gas form is approx. 1 bar greater.Opening differential pressure Max. working Type

with standard coil (D p bar)Temperature pressure

k v -value Max. (= MOPD) liquid 2)of medium PB

Min.10 W a.c.12 W a.c.20 W d.c.°C bar

m 3/h EVRA 30.00212514–40 ® 105280.23EVRA 100.05212518–40 ® 10528 1.5EVRA 150.05212518–40 ® 10528 2.7EVRA 200.05212513–40 ® 10528 4.5EVRA 250.2212514–40 ® 1052810.0EVRA 320.2212514–40 ® 1052816.0EVRA 400.2212514–40 ® 1052825.0

Data sheet Solenoid valves, type EVRA 3 ® 40

Technical data (continued)

1)Rated liquid and suction vapour capacity is based on evaporating temperature t e = -10°C, liquid temperature ahead of valve t l = +25°C,

and pressure drop across valve D p = 0.15 bar.

Rated capacity 1) [kW]

Type

Liquid

Suction vapour

Hot gas

R717R22R134a R404A

R717R22R134a R404A

R717R22R134a R404A EVRA321.8 4.6 4.3 3.2 6.5 2.1 1.7 1.7

EVRA10142.030.227.821.19.0 3.4 2.5 3.142.613.911.011.3EVRA15256.054.450.138.016.1 6.2 4.4 5.576.724.919.820.3EVRA20426.090.683.563.326.910.37.39.2128.041.532.933.9EVRA25947.0201.0186.0141.059.722.816.320.4284.092.373.275.3EVRA321515.0322.0297.0225.095.536.526.132.6454.0148.0117.0120.0EVRA402368.0503.0464.0351.0149.057.040.851.0710.0231.0183.0188.0

Coils

See "Coils for solenoid valves", RD.3J.B2.02.Accessories

Strainer FA for direct mounting, see "FA".Example

EVRA 15 complete valve with terminal box,220 V, 50 Hz, code no. 032F6218

+ 3/4 in. weld flange set, code no. 027N1120.Example

EVRA 15 valve body with manual operation,code no. 032F6215

+ 3/4 in. weld flange set, code no. 027N1120+ coil with terminal box, 220 V, 50 Hz,code no. 018Z6701

(see "Coils for solenoid valves").

Flange set

3/8027N11121/2027N1115

5/816027L1117027L1116

3/4027N1120

7/822

027L1123027L1122

3/4

027N1220

7/822027L1223027L1222

1027N1225

11/828027L1229027L1228

1027N122511/4

027N1130

Connection in.mm

in.

mm

in.

Solder Weld Code no.Valve type

EVRA 3,10 and 15

EVRA 20and 25

Separate valve bodies

Code no.

Type

Connection

Required Steel GGG-40.3GG-25GGG-40.3coil type

Valve house with necessary flange gasket and bolts;Weld connection (without coil)(without coil and flanges)

Valves with manual operation EVRA 10 a.c. / d.c.

-032F6210--EVRA 15Se table a.c. / d.c.-032F6215--EVRA 20Flange set a.c.-032F6220--EVRA 20 d.c.-032F6221--EVRA 25 a.c. / d.c.-032F6225

--EVRA 3211/4 in. a.c. / d.c.-042H1121042H1126EVRA 4011/2 in. a.c. / d.c.-

042H1123042H1128

Valves without manual operation EVRA 3Se table a.c. / d.c.032F3050

---EVRA 10Flange set a.c. / d.c.-032F6211--EVRA 25 a.c. / d.c.-032F6226

--EVRA 3211/4 in. a.c. / d.c.--042H1122042H1127EVRA 4011/2 in.

a.c. / d.c.--042H1124042H1129

Ordering Complete valves without flanges

Code no. 1)

Type

Connection

Steel GGG-40.3Steel GGG-40.310 W coil with 1 m cable

10 W coil with terminal box

Valves without manual operation EVRA 3

Se table Flange set

032F3102

-032F3013

-EVRA 10

-032F6207-032F6208

Valves with manual operation EVRA 10-032F6212-032F6213EVRA 15Se table Flange set -032F6217-032F6218EVRA 20

-032F6222-032F6223

1)

Valve body with gaskets, bolts and 10 W a.c. coil. Please specify code no., voltage and frequency. Voltage and frequency can also be given in the form of an appendix number, see table "Appendix numbers", under EVR.

Rated hot gas capacity is based on condensing tempera-ture t c = +40°C,

pressure drop across valve D p = 0.8 bar,hot gas temperature t h = +65°C,

and subcooling of refrigerant D t sub = 4 K.