参考文献

[1] Patel P,Banchs JE,Stevenson RT,et al. Distal balloon occlusion

allows epicardial lead placement in a tortuous branch of the great cardiac vein[J]. J Interv Card Electrophysiol,2009,25(2): 159-161.

[2] Solzbach U,Haas H. Placement of a Left Ventricular Pacing Lead

After Balloon Angioplasty of a Coronary Vein Stenosis: Coronary Sinus Obstruction as a Complication After Mitral Valve Operation [J]. Circulation,2008,118(9): 136-137.

[3] TORI G. Radiological visualization of the coronary sinus and

coronary veins[J]. Acto Radio1,1951,36(5):405-410.

[4] von Ludinghausen M. The venous drainage of the human myocardium

[J]. Adv Anat Embryol Cell Biol,2003,168: 1-104.

在对照组逐渐增加,差异有统计学意义[(84.7±9.5)Vs (89.4±5.2)vs (91.5±6.8)P <0.05]。mPAP 在实验组阻塞后30、60、120 min 逐渐增加,差异有统计学意义[(22.9±3.2)vs (25.1±3.5)vs (33.0±2.9)P <0.05];在对照组未见变化[(18.0±1.7)vs (18.3±2.9)vs (17.5±3.2)P >0.05]。PCWP 在实验组阻塞后30、60、120 min 逐渐增加,差异有统计学意义[(10.7±1.6)vs (15.7±2.7)vs (27.6±6.0)P <0.05];在对照组未见变化[(12.3±1.5)vs (12.1±1.5)vs (13.0±1.3)P >0.05]。

3 讨论

本研究表明冠状窦阻塞可导致mPAP 和PCWP 增高,mFEM 降低;而对照组亦有较小波动可能与开胸手术有关。由此可以看出冠状窦阻塞对心脏血流动力学的影响是十分显著的。随着冠状

3]认为右心尿流动力学的临床应用评价

张万生 于 航 郭彬彬 腾 飞 王立国

【摘要】目的 尿流动力学检查的临床应用评价。方法 回顾性分析我院门诊及住院患者2 040例;选用加拿大LABORIE 公司的尿流动力学检查仪进行尿流率检测、充盈期膀胱测压和排尿期同步压力流率测定、同步尿道外括约肌肌电图测定,从而结合临床资料判定尿流动力学诊断。结果 膀胱出口梗阻846例,占41.47%;膀胱出口可疑梗阻222例,占10.88%;神经源性膀胱尿道功能障碍448例,占21.96%;膀胱过度活动症134例,占6.57%;膀胱逼尿肌无力/乏力260例,占12.75%;膀胱出口无梗阻及尿流动力学检查未见异常患者86例,占4.22%;其他如高/低顺应性膀胱等44例,占2.16%。结论 尿流动力学是明确下尿路症状原因的重要检查手段,具有较高临床应用价值。【关键词】尿流动力学;临床应用;评价 【中图分类号】R696 【文献标识码】B 【文章编号】1674-9316(2015)28-0082-02doi:10.3969/j.issn.1674-9316.2015.28.063

Clinical Application Evaluation of Urodynamics

ZHANG Wansheng YU Hang GUO Binbin TENG Fei WANG Liguo Department of Urology,the Affiliated Hospital of Jinlin Medical College,Jilin 132013,China 【Abstract】

Objective To study the clinical application evaluation of urodynamics. Methods We summaried our experience of 2 040 consecutive urodynamic examinations,We tested urinary flow rate,filling stage of bladder pressure and bladder pressure flow rate,simultaneous urethral external sphincter electromyography using urodynamics inspection instrument from LABORIE company in canda. Results Bladder outlet obstruction,846 cases,accounted for 41.47%,bladder outlet suspicious obstruction,222 cases,accounted for 10.88%,neurogenic dysfunction of bladder and urethra,448 cases,accounted for 21.96%,overactive bladder 134 cases,accounting for 6.57%,bladder detrusor muscle weakness/fatigue,260 cases,12.75%,as for bladder outlet without obstruction and urinary flow dynamics examination,there were 86 healthy people,accounted for 4.22%,others,such as high/low compliant bladder 44 cases,2.16%. Conclusion The urodynamics has high clinical application value in the clinical application.【Key words】 Urodynamics,Clinical application,Evaluation

尿流动力学检查利用流体力学和电生理学的原理和方法[1],模拟出人体在排尿过程中的尿路各部压力、尿流率及肌电活动,

从而通过电脑处理数据,反应出整个尿路的情况。

1 资料与方法1.1 一般资料

本次选择我院2007年5月~2015年5月尿流动力学门诊及住院患者2 040例为例案。患者年龄19~93岁,平均(72±21)岁。

作者单位:132013 吉林医药学院附属医院泌尿外科通讯作者:王立国,E-mail :urolancet@