HT190E01-100 Product Spec
超米特电子有限公司产品说明书
1US Headquarters TEL +(1) 781-935-4850FAX +(1) 781-933-4318 • Europe TEL +(44) 1628 404000FAX +(44) 1628 404090Asia Pacific TEL +(852) 2 428 8008FAX +(852) 2 423 8253South America TEL +(55) 11 3917 1099FAX +(55) 11 3917 0817Superior elongation and tensilestrength help to prevent tearing in use due to mishandling. Typical properties for CHO-SEAL 1310 and 1273 materi-al are shown on pages 33 and 32respectively.High Shielding PerformanceCHO-SEAL 1310 material provides more than 80 dB of shielding effectiv-ness from 100 MHz to 10 GHz, while CHO-SEAL 1273 material provides more than 100 dB.Low Volume ResistivityBoth materials have exceptionally low volume resistivity, which makes them well suited for grounding appli-cations in which a flexible electrical contact is needed.Low Compression GasketSpacer gaskets are typicallydesigned to function under low deflec-tion forces. Chomerics uses design tools such as Finite Element Analysis (FEA) to accurately predict compres-sion-deflection behavior of various cross section options. Refer to page16.LCP Plastic SpacerLiquid crystal polymer (LCP)spacers, including those made with Vectra A130 material, provide aCHO-SEAL ®1310 or 1273Conductive ElastomersWith EMI spacer gaskets, shielding and grounding are provided by Chomerics’CHO-SEAL 1310 and 1273 conductive elastomers, specifi-cally formulated for custom shape molded parts. They provide excellent shielding and isolation against electro-magnetic interference (EMI), or act as a low impedance ground path between PCB traces and shielding media. Physically tough, these elas-tomers minimize the risk of gasket damage, in contrast to thin-walled extrusions or unsupported molded gaskets.Silicone-based CHO-SEAL 1310and 1273 materials offer excellent resistance to compression set over a wide temperature range, resulting in years of continuous service. CHO-SEAL 1310 material is filled with silver-plated-glass particles, while 1273 utilizes silver-plated-copper filler to provide higher levels of EMI shielding effectiveness.EMI Spacer GasketsThe unique design of Chomerics’EMI spacer gaskets features a thin plastic retainer frame onto which a conductive elastomer is molded. The elastomer can be located inside or outside the retainer frame, as well as on its top and bottom surface. EMI spacer gaskets provide a newapproach to designing EMI gaskets into handheld electronics such as dig-ital cellular phones. Board-to-board spacing is custom designed to fit broad application needs. Customized cross sections and spacer shapes allow for very low closure forcerequirements and a perfect fit in any design or device.Robotic InstallationSpacer gaskets can be installed quickly by robotic application. Integral locater pins in the plastic spacer help ensure accuratepositioning in both manual and pick-and-place assembly. Benefits include faster assembly and lower labor costs.The integrated conductive elastomer/plastic spacer gasket is a low cost,easily installed system for providing EMI shielding and grounding in small electronic enclosures.Figure 1Single Piece EMI Gasket/Locator PinsCHO-SEAL 1310 or 1273 Conductive Elastomer (Inside)Plastic Spacer Around Outsideor InsideApplications for EMI Spacer GasketsThe spacer gasket concept is especially suited to digital and dual board telephone handsets or other handheld electronic devices. It provides a low impedance path between peripheral ground traces on printed circuit boards and components such as:•the conductive coating on a plastic housing•another printed circuit board •the keypad assemblyTypical applications for EMI spacer gaskets include:•Digital cellular, handyphone and personal communications services (PCS) handsets •PCMCIA cards•Global Positioning Systems (GPS)•Radio receivers•Other handheld electronics, e.g.,personal digital assistants (PDAs)•Replacements for metal EMI shield-ing “fences” on printedcircuit boards in wireless tele-communications devicesstable platform for direct, highprecision molding of conductive elas-tomers. The Vectra A130 material described in Table 1 has excellent heat deflection temperature character-istics (489°F, 254°C). For weight con-siderations, the LCP has aspecific gravity of only 1.61. This plas-tic is also 100% recyclable.Typical EMI Spacer Gasket Design ParametersThe EMI spacer gasket concept can be considered using the design parameters shown in Table 2. Some typical spacer gasket profiles are shown below.Figure 2Typical Spacer Gasket Profiles3US Headquarters TEL +(1) 781-935-4850FAX +(1) 781-933-4318 • Europe TEL +(44) 1628 404000FAX +(44) 1628 404090Asia Pacific TEL +(852) 2 428 8008FAX +(852) 2 423 8253South America TEL +(55) 11 3917 1099FAX +(55) 11 3917 0817Finite Element AnalysisChomerics, a division of the Parker Hannifin Corporation’s Seal Group, is the headquarters of Parker Seal’s Elastomer Simulation Group. This unit specializes in elastomer finite element analysis (FEA) using MARC K6 series software as a foundation for FEA capability.Benefits of FEA include:•Quickly optimizing elastomer gasket designs•Allowing accurate predictions of alternate elastomer design concepts •Eliminating extensive trial and error prototype evaluationTypical use of FEA in EMI spacer gasket designs is to evaluate the force vs. deflection requirements of alternate designs.For example, onespacer design features a continuous bead of con-ductive elastomer molded onto a plastic spacer. An alternative designemploys an “interrupted bead,” where the interrup-tions (gaps left on the plastic frame) are sized to maintain the requiredlevel of EMI shielding. Figure 4illustrates these alternative designs.Gasket DeflectionFigure 5 compares the effect of continuous and interrupted elastomer gasket designs in terms of the force required to deflect the conductive elastomer. This actual cellular handset application required a spacer gasket with interrupted bead to meet desired deflection forces.Chomerics Designand Application ServicesChomerics will custom design a spacer for your application. Advice,analysis and design assistance will be provided by Chomerics Applications and Design engineers at no additional fee. Contact Chomerics directlyat the locations listed at the bottom of the page.Figure 3FEA Example of an EMISpacer Gasket Cross SectionFigure 4Continuous (top) and InterruptedElastomer GasketsFigure 5Typical Spacer Gasket Deflection。
HT170E01-101
PROPRIETARY NOTE THIS SPECIFICATION IS THE PROPERTY OF BOE TFT-LCD SBU AND SHALL NOT BE REPRODUCED OR COPIED WITHOUT THE WRITTEN PERMISSION OF BOE TFTLCD SBU AND MUST BE RETURNED TO BOE TFT-LCD SBU UPON ITS REQUESTTITLE : HT170E01-101 Product Specification Rev. ABOE TFT-LCD SBUBEIJING BOE OPTOELECTRONICS TECHNOLOGY BOE HYDIS TECHNOLOGYSPEC. NUMBER S864-1240 B2003-002-B(1/3)PRODUCT GROUP TFT-LCDREV. AISSUE DATE 2005.09.16.PAGE 1 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.REVISION HISTORYREV. O A ECN NO. DESCRIPTION OF CHANGES Initial Release Add In-Rush Current Spec (7 page) DATE 05.08.31. 05.09.16 PREPARED W.K.CHANG W.K.CHANGSPEC. NUMBER S864-1240 B2003-002-B(2/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 2 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.ContentsNo. 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 General Description Absolute Maximum Ratings Electrical Specifications Optical Specifications Interface Connection Signal Timing Specifications Input Signals, Basic Display Colors & Gray Scale of Colors Power Sequence Mechanical Characteristics Reliability Test Handling & Cautions Product Serial Number Packing Appendix Item Page 4 6 7 8 10 13 16 17 18 19 20 21 22 24SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 3 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.1.0 GENERAL DESCRIPTION1.1 Introduction HT170E01-101 is a color active matrix TFT LCD module using amorphous silicon TFT's (Thin Film Transistors) as an active switching devices. This module has a 17.0 inch diagonally measured active area with SXGA resolutions (1280 horizontal by 1024 vertical pixel array). Each pixel is divided into RED, GREEN, BLUE dots which are arranged in vertical stripe and this module can display 16,194,227 colors. The TFT-LCD panel used for this module is adapted for a low reflection and higher color type.CN21 CN22LVDS Input SignalConnector (CN1 )LVDS Rx + T/CON + mini-LVDS TxSource DriverGate DriverVDDDC/DC Gamma VcomTFT LCD Panel 1280 ×1024CN23 CN241.2 Features LVDS Interface with 2 pixel / clock High-speed response Low power consumption 6-bit (FRC) color depth, display 16,194,227 colors Incorporated edge type back-light (Four lamps) High luminance and contrast ratio, low reflection and wide viewing angle DE (Data Enable) & H-Sync & V-Sync mode RoHS CompliantSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 4 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT 1.3 Application Desktop Type of PC & Workstation Use Slim-Size Display for Stand-alone Monitor Display Terminals for Control System Monitors for Process ControllerREV AISSUE DATE 05.09.16.1.4 General Specification The followings are general specifications at the model HT170E01-101. <Table 1. General Specifications> Parameter Active area Number of pixels Pixel pitch Pixel arrangement Display colors Display mode Dimensional outline Weight Surface Treatment Back-light Specification 337.92(H) * 270.336(V) 1280(H) ×1024(V) 0.264(H) ×0.264(V) RGB Vertical stripe 16,194,227 Normally White 358.5(H) × 296.5(V) × 17.0(D) typ. 1900 (max.) Haze 25%, 3H Top/Bottom edge side, 4-CCFL type Note 1 mm gram colors Unit mm pixels mmRemarksNote : 1. CCFL (Cold Cathode Fluorescent Lamp)SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 5 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.2.0 ABSOLUTE MAXIMUM RATINGSThe followings are maximum values which, if exceed, may cause faulty operation or damage to the unit. The operational and non-operational maximum voltage and current values are listed in Table 2. < Table 2. Absolute Maximum Ratings>Parameter Power Supply Voltage Logic Supply Voltage Back-light Lamp Current Back-light Lamp Frequency Operating Temperature Storage Temperature Symbol VDD VIN IBL FL TOP TST Min. VSS-0.5 VSS-0.3 3 30 0 -20 Max. 6.5 VDD+0.3 7 (80) +50 +60 Unit V V mA KHz ℃ ℃ 1) 1) Ta = 25 ℃ [VSS=GND=0V] RemarksNote : 1) Temperature and relative humidity range are shown in the figure below. Wet bulb temperature should be 39 OC max. and no condensation of water.100 90 80Relative Humidity (%RH)60O p e ra tin g R a n g e4020S to ra g e R a n g e5 -2 0 0 20 40 60 80T e m p e ra tu re (˚ C)SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 6 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.3.0 ELECTRICAL SPECIFICATIONS< Table 3. Electrical specifications >Parameter Power Supply Voltage Power Supply Current In Rush Current Permissible Input Ripple Voltage High Level Differential Input Threshold Voltage Low Level Differential Input Threshold Voltage Back-light Lamp Voltage Back-light Lamp Current Back-light Lamp operating Frequency Lamp Start Voltage Lamp Life PD Power Consumption PBL Ptotal 40000 50000 3.75 18.33 22.1 4.5 ← 22.83 VDD IDD Irush VRF VIH VIL VBL IBL FL -100 560 3.0 30 700 6.5 840 7.0 70 1400 1700 Min. 4.5 Typ. 5.0 750 2.0 Max. 5.5 900 3.0 100 +100 Unit V mA A mV mV Vcm = 1.2V typ. mV Vrms mArms KHz Vrms Vrms Hrs W W W IBL=6.5mA, Note 6 Note 3 25 ℃ Note 4 0℃ Note 5 [Ta =25±2 ℃] RemarksNote 1 Note 2 VDD = 5.0VIBL= 6.5mANotes : 1. The supply voltage is measured and specified at the interface connector of LCM. The current draw and power consumption specified is for VDD=5.0V, Frame rate=75Hz and Clock frequency = 67.5MHz. Test Pattern of power supply current a) Typ : Black Pattern b) Max : Dot Pattern 2. Duration of rush current is about 2 ms and rising time of VDD is 520 μs ± 20 % 3. The lamp frequency should be selected as different as possible from the horizontal synchronous frequency and its harmonics to avoid interference, which may cause line flow on the display 4. The voltage above this value should be applied to the lamps for more than 1 second to start-up. Otherwise the lamps may not be turned on. 5. Calculated value for reference (VBL × IBL) ×4 excluding inverter loss.SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 7 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.4.0 OPTICAL SPECIFICATION4.1 OverviewThe test of Optical specifications shall be measured in a dark room (ambient luminance ≤ 1 lux and temperature = 25±2℃) with the equipment of Luminance meter system (Goniometer system and TOPCON BM-5) and test unit shall be located at an approximate distance 50cm from the LCD surface at a viewing angle of θ and Φ equal to 0°. We refer to θØ=0 (=θ3 ) as the 3 o’clock direction (the “right”), θØ=90 (= θ12 ) as the 12 o’clock direction (“upward”), θØ=180 (= θ9 ) as the 9 o’clock direction (“left”) and θØ=270(= θ6 ) as the 6 o’clock direction (“bottom”). While scanning θ and/or Ø, the center of the measuring spot on the Display surface shall stay fixed. The measurement shall be executed after 30 minutes warm-up period. VDD shall be 5.0V +/-10% at 25°C. Optimum viewing angle direction is 6 ’clock.4.2 Optical Specifications[VDD = 5.0V, Frame rate = 60Hz, Clock = 54MHz, IBL = 6.5mA, Ta =25±2 ℃] ParameterHorizontal Viewing Angle VerticalSymbolΘ3 Θ9 Θ12 Θ6 Θ3 Θ9 Θ12 Θ6 CR Yw ΔY Wx Wy Rx Ry Gx Gy Bx By Tr Tf CTConditionMin.65 65 65 50 70 70 70 70 450 250 75 0.283 0.299 0.617 0.307 0.253 0.570 0.112 0.054Typ.75 75 75 60 80 80 80 80 700 300 0.313 0.329 0.647 0.337 0.283 0.600 0.142 0.084 2 6Max.-UnitDeg. Deg. Deg. Deg. Deg. Deg. Deg. Deg.RemarkNote 1CR > 10Horizontal Viewing Angle Vertical Contrast ratio Luminance of White White luminance uniformity WhiteCR > 5Note 1Note 2 cd/m 0.343 0.359 0.677 0.367 0.313 0.630 0.172 0.114 4 8 2.0 ms ms % Note 7 Note 6 Note 5 %2Note 3 Note 4Red Reproduction of color GreenΘ = 0° (Center) Normal Viewing AngleBlue Response Time Cross Talk Rising Falling--SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 8 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.Note :1. Viewing angle is the angle at which the contrast ratio is greater than 10. The viewing are determined for the horizontal or 3, 9 o’clock direction and the vertical or 6, 12 o’clock direction with respect to the optical axis which is normal to the LCD surface. 2. Contrast measurements shall be made at viewing angle of θ= 0° and at the center of the LCD surface. Luminance shall be measured with all pixels in the view field set first to white, then to the dark (black) state. (See FIGURE 1 shown in Appendix) Luminance Contrast Ratio (CR) is defined mathematically. Luminance when displaying a white raster Luminance when displaying a black rasterCR=3. Center Luminance of white is defined as the LCD surface. Luminance shall be measured with all pixels in the view field set first to white. This measurement shall be taken at the locations shown in FIGURE 2 for a total of the measurements per display. 4. The White luminance uniformity on LCD surface is then expressed as : ΔY = ( Minimum Luminance of 9points / Maximum Luminance of 9points ) * 100 (See FIGURE 2 shown in Appendix). 5. The color chromaticity coordinates specified in Table 4. shall be calculated from the spectral data measured with all pixels first in red, green, blue and white. Measurements shall be made at the center of the panel. 6. The electro-optical response time measurements shall be made as FIGURE 3 shown in Appendix by switching the “data” input signal ON and OFF. The times needed for the luminance to change from 10% to 90% is Td, and 90% to 10% is Tr. 7. Cross-Talk of one area of the LCD surface by another shall be measured by comparing the luminance (YA) of a 25mm diameter area, with all display pixels set to a gray level, to the luminance (YB) of that same area when any adjacent area is driven dark. (See FIGURE 4 shown in Appendix).SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 9 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.5.0INTERFACE CONNECTION.● CN115.1 Electrical Interface Connection Mode Side Connector : JAE FI-XB30SSL-HF15 or Equivalent User Side Connector : JAE FI-X30H or EquivalentFunction LVDS ODD 0- SIGNAL LVDS ODD 0+ SIGNAL LVDS ODD 1- SIGNAL LVDS ODD 1+ SIGNAL LVDS ODD 2- SIGNAL LVDS ODD 2+ SIGNAL GROUND LVDS ODD CLOCK- SIGNAL LVDS ODD CLOCK+ SIGNAL LVDS ODD 3- SIGNAL LVDS ODD 3+ SIGNAL LVDS EVEN 0- SIGNAL LVDS EVEN 0+ SIGNAL GROUND LVDS EVEN 1- SIGNAL LVDS EVEN 1+ SIGNAL GROUND LVDS EVEN 2- SIGNAL LVDS EVEN 2+ SIGNAL LVDS EVEN CLOCK- SIGNAL LVDS EVEN CLOCK+ SIGNAL LVDS EVEN 3- SIGNAL LVDS EVEN 3+ SIGNAL GROUND NO CONNECTION NO CONNECTION NO CONNECTION POWER SUPPLY ( +5.0 V ) RemarkPin No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30Symbol RXO0RXO0+ RXO1RXO1+ RXO2RXO2+ GND RXOCLKRXOCLK+ RXO3RXO3+ RXE0RXE0+ GND RXE1RXE1+ GND RXE2RXE2+ RXECLKRXECLK+ RXE3RXE3+ GND NC DE NC VDD VDD VDDSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 10 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.5.2 LVDS Interface5.2.1 Odd LVDS Transmitter (Tx; THC63LVDF83A or Equivalent) Signal InterfaceTransmitter Pin No. 51 52 54 55 56 3 4 6 7 11 12 14 15 19 20 22 23 24 27 28 30 31 50 2 8 10 16 18 25 Pin No. Interface System (Tx) TFT-LCD (Rx) HT170E01-101 (CN11) Pin No. RemarkInput Signal OR0 OR1 OR2 OR3 OR4 OR5 OG0 OG1 OG2 OG3 OG4 OG5 OB0 OB1 OB2 OB3 OB4 OB5 Hsync Vsync DE MCLK OR6 OR7 OG6 OG7 OB6 OB7 RSVD48 47OUT0OUT0+RXO0RXO0+1 246 45OUT1OUT1+RXO1RXO1+3 4O D D L V D S42 41OUT2OUT2+RXO2RXO2+5 640 39CLK OUTCLK OUT+RXO CLKRXO CLK+8 938 37OUT3OUT3+RXO3RXO3+10 11SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 11 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.5.2.2 Even LVDS Transmitter (Tx; THC63LVDF83A or Equivalent) Signal InterfaceTransmitter Pin No. 51 52 54 55 56 3 4 6 7 11 12 14 15 19 20 22 23 24 27 28 30 31 50 2 8 10 16 18 25 Pin No. Interface System (Tx) TFT-LCD (Rx) HT170E01-101 (CN11) Pin No. RemarkInput Signal ER0 ER1 ER2 ER3 ER4 ER5 EG0 EG1 EG2 EG3 EG4 EG5 EB0 EB1 EB2 EB3 EB4 EB5 Hsync Vsync DE MCLK ER6 ER7 EG6 EG7 EB6 EB7 RSVD48 47OUT0OUT0+RXO0RXO0+12 1346 45OUT1OUT1+RXO1RXO1+15 16E V E N L V D S42 41OUT2OUT2+RXO2RXO2+18 1940 39CLK OUTCLK OUT+RXO CLKRXO CLK+20 2138 37OUT3OUT3+RXO3RXO3+22 23SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 12 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT 5.3 Data Input FormatODD (1,1) R G B EVEN (2,1) R G B 1 Pixel = 3 Dots R G BREV AISSUE DATE 05.09.16.(1279,1) R G B(1280,1) R G BR G B (1,1024)R G B (2,1024)RG BR G BDisplay Position of Input Data (V-H)(1279,1024) (1280, 1024)5.4 Back-light Interface Connection●CN 21,22,23,24 Module Side Connector User Side Connector : BHSR-02VS-1 (JST) : SM02B-BHSS-1-TB(JST) or EquivalentPin No. 1 2INPUT HOT COLDColor Pink & Blue Black & WhiteFunction High Voltage Ground6.0 SIGNAL TIMING SPECIFICATION6.1 Timing Parameters (DE & H-Sync & V-Sync mode)Item Frequency Clock High Time Low Time Setup Time Data Hold Time Data Enable Setup Time Frame Period Vertical Display Period One Line Scanning Period Horizontal Display Period Symbols 1/Tc Tch Tcl Tds Tdh Tes Tv Tvd Th Tdh Min 40 4 4 4 4 4 1032 13.33 672 640 Typ 54 1066 16.67 1024 844 640 Max 68 1536 1022 640 Unit MHz ns ns ns ns ns lines msec lines clocks clocksSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 13 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.Tv Tvd ThEN AB D at ax, 1 x, 2 Th T hd x, 768 I n val i d D at a x+ 1, 1C LKTcEN AB D at aD1 D2 D3. . . T cl 0. 5V D DD1022 D1023 D1024I n val i d D at aD1D2. . .T chC LKTds TdhD at aTes0. 5V D DEN AB0. 5V D DV-SyncOver 3 H-syncH-Sync Fix H-Sync width AreaDE1) Need over 3 H-Sync during V-Sync Low Period 2) Fix H-Sync width form V-Sync falling edge to first DE rising edgeSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 14 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT 6.2 LVDS Rx Interface Timing ParameterREV AISSUE DATE 05.09.16.The specification of the LVDS Rx interface timing parameter is shown in Table 4. <Table 4. LVDS Rx Interface Timing Specification>Item CLKIN Period CLK Difference Input Data 0 Input Data 1 Input Data 2 Input Data 3 Input Data 4 Input Data 5 Input Data 6 Symbol tRCIP tCdiff tRIP1 tRIP0 tRIP6 tRIP5 tRIP4 tRIP3 tRIP2 Min 14.7 -tRCIP*(3/7) -0.4 tRICP/7-0.4 2 ×tRICP/7-0.4 3 ×tRICP/7-0.4 4 ×tRICP/7-0.4 5 ×tRICP/7-0.4 6 ×tRICP/7-0.4 Typ 18.5 0 0.0 tRICP/7 2 ×tRICP/7 3 ×tRICP/7 4 ×tRICP/7 5 ×tRICP/7 6 ×tRICP/7 Max +tRCIP*(3/7) +0.4 tRICP/7+0.4 2 ×tRICP/7+0.4 3 ×tRICP/7+0.4 4 ×tRICP/7+0.4 5 ×tRICP/7+0.4 6 ×tRICP/7+0.4 Unit msec nsec nsec nsec nsec nsec nsec nsec nsec RemarktRIP2 tRIP3 tRIP4 tRIP5 tRIP6 tRIP0 tRIP1 RXO/Ez +/* Z = 0, 1, 2,3 RxCLKIN+Rx3 Rx2 Rx1 Rx0 Rx6 Rx5 Rx4 Rx3 Rx2 Rx1 Rx0Vdiff=0[v]tRCIPVdiff=0[v]RxCLKIN+tCdiff * Vdiff = (RXO/Ez+)-(RXO/Ez-),…. ,(RXO/ECLK+)-(RXO/ECLK-)SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 15 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.7.0 INPUT SIGNALS, BASIC DISPLAY COLORS & GRAY SCALE OF COLORSColor & Gray ScaleBlack Blue Green Cyan Red Magenta Yellow White Black △ Darker △ ▽ Brighter ▽ Red Black △ Darker △ ▽ Brighter ▽ Green Black △ Darker △ ▽ Brighter ▽ Blue Black △ Darker △ ▽ Brighter ▽ WhiteRed DataR7 0 0 0 0 1 1 1 1 0 0 0 R6 0 0 0 0 1 1 1 1 0 0 0 R5 0 0 0 0 1 1 1 1 0 0 0 R4 R3 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 ↑ ↓ 1 1 1 1 1 1 0 0 0 0 0 0 ↑ ↓ 0 0 0 0 0 0 0 0 0 0 0 0 ↑ ↓ 0 0 0 0 0 0 0 0 0 0 0 0 ↑ ↓ 1 1 1 1 1 1 R2 0 0 0 0 1 1 1 1 0 0 0 R1 0 0 0 0 1 1 1 1 0 0 1Green DataR0 G7 G6 G5 G4 G3 G2 G1 G0 B7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 1 1 1 1 1 1 1 0 0 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ↑ ↓ 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 ↑ ↓ 0 1 1 1 1 1 1 0 1 0 0 1 1 1 1 1 1 1 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ↑ ↓ 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 ↑ ↓ 1 1 1 1 1 1 1 0 1 1 0 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 B6 0 1 0 1 0 1 0 1 0 0 0Blue DataB5 0 1 0 1 0 1 0 1 0 0 0 B4 B3 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 0 0 0 0 ↑ ↓ 0 0 0 0 0 0 0 0 0 0 0 0 ↑ ↓ 0 0 0 0 0 0 0 0 0 0 0 0 ↑ ↓ 1 1 1 1 1 1 0 0 0 0 0 0 ↑ ↓ 1 1 1 1 1 1 B2 0 1 0 1 0 1 0 1 0 0 0 B1 0 1 0 1 0 1 0 1 0 0 0 B0 0 1 0 1 0 1 0 1 0 0 0Basic ColorsGray Scale of RedGray Scale of Green1 1 1 0 0 01 1 1 0 0 01 1 1 0 0 01 1 1 0 0 00 1 1 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 0Gray Scale of Blue0 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 10 0 0 0 1 0Gray Scale of White0 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 00 0 0 0 0 11 1 1 0 0 01 1 1 0 0 01 1 1 0 0 00 1 1 0 0 11 0 1 0 1 01 1 1 1 1 1 1 1 11 0 1 1 1 11 1 1 1 1 11 0 1 1 1 0 1 1 1SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 16 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.8.0 POWER SEQUENCETo prevent a latch-up or DC operation of the LCD module, the power on/off sequence shall be as shown in below0.9VDD0.9VDD 0.1VDDPower Supply0V0.1VDDT1 T2 Valid0VT5T6Interface SignalT3T4Back- light0V0 ● 0 ● 200ms ● 100ms ● 0 ● 1 sec●< ≤ ≤ ≤ ≤ ≤T1 ≤ 10 ms T2 ≤ 50 ms T3 T4 T5 ≤ 50ms T6Notes: 1. When the power supply VDD is 0V, Keep the level of input signals on the low or keep high impedance. 2. Do not keep the interface signal high impedance when power is on. 3. Back Light must be turn on after power for logic and interface signal are valid.SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 17 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.9.0 MECHANICAL CHARACTERISTICS9.1 Dimensional Requirements FIGURE 6 (located in Appendix) shows mechanical outlines for the model HT170E01-101. Other parameters are shown in Table 5. <Table 5. Dimensional Parameters>Parameter Dimensional outline Weight Active area Pixel pitch Number of pixels Back-light Specification 358.5 (H) ×296.5 (V) ×17.0 (D) ±0.5 1900 max. 337.92 (H) ×270.336(V) 0.264(H) ×0.264(V) 1280(H) ×1024(V) (1 pixel = R + G + B dots) Top / Bottom edge side 4-CCFL type Unit mm gram mm mm pixels9.2 Mounting See FIGURE 5. (shown in Appendix)9.3 Anti-Glare and Polarizer Hardness. The surface of the LCD has an anti-glare coating to minimize reflection and a coating to reduce scratching.9.4 Light Leakage There shall not be visible light from the back-lighting system around the edges of the screen as seen from a distance 50cm from the screen with an overhead light level of 350 [lux.]SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 18 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.10.0 RELIABLITY TESTThe Reliability test items and its conditions are shown in below. <Table 6. Reliability Test Parameters > No 1 2 3 4 5 6 Test ItemsHigh temperature storage test Low temperature storage test High temperature & high humidity operation test High temperature operation test Low temperature operation test Thermal shock Ta = 60 ℃, 240 hrs Ta = -20 ℃, 240 hrs Ta = 50 ℃, 80%RH, 240hrs Ta = 50 ℃, 240hrs Ta = 0 ℃, 240hrs Ta = -20 ℃ ↔ 60 ℃ (0.5 hr), 100 cycle Frequency : 10 ~ 300 Hz, Sweep rate 30 minConditions7Vibration test (non-operating)Gravity / AMP : 1.5 G Period : ±X, ±Y, ±Z 30 minGravity: 70G8Shock test (non-operating)Pluse width : 11msec, sine wave ±X, ±Y, ±Z Once for each direction Air : 150 pF, 330Ω, 15 KV9Electro-static discharge test Contact : 150 pF, 330Ω, 8 KVSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 19 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.11.0 HANDLING & CAUTIONS(1) Cautions when taking out the module Pick the pouch only, when taking out module from a shipping package. (2) Cautions for handling the module As the electrostatic discharges may break the LCD module, handle the LCD module with care. Peel a protection sheet off from the LCD panel surface as slowly as possible. As the LCD panel and back - light element are made from fragile glass material, impulse and pressure to the LCD module should be avoided. As the surface of the polarizer is very soft and easily scratched, use a soft dry cloth without chemicals for cleaning. Do not pull the interface connector in or out while the LCD module is operating. Put the module display side down on a flat horizontal plane. Handle connectors and cables with care. (3) Cautions for the operation When the module is operating, do not lose CLK, ENAB signals. If any one of these signals is lost, the LCD panel would be damaged. Obey the supply voltage sequence. If wrong sequence is applied, the module would be damaged. (4) Cautions for the atmosphere Dew drop atmosphere should be avoided. Do not store and/or operate the LCD module in a high temperature and/or humidity atmosphere. Storage in an electro-conductive polymer packing pouch and under relatively low temperature atmosphere is recommended. (5) Cautions for the module characteristics Do not apply fixed pattern data signal to the LCD module at product aging. Applying fixed pattern for a long time may cause image sticking. (6) Other cautions Do not disassemble and/or re-assemble LCD module. Do not re-adjust variable resistor or switch etc. When returning the module for repair or etc., Please pack the module not to be broken. We recommend to use the original shipping packages.SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 20 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.12.0 PRODUCT SERIAL NUMBERHT170E01 - 101XXXXXX101XXXXXXXX1X X2X3X4X5X6 107X X X X X2 - X X XType designation No 1. Control Number No 2. Rank / Grade No 3. Line Classification (H:BOE HYDIS, L:LCM, A/B/C:BOE OT) No 4. Year (5 : 2005, 6 : 2006, …) No 5. Month (1, 2, 3,…, 9, X, Y, Z) No 6. FG Code No 7. Serial NumberSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 21 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.13.0 PACKING13.1 Packing OrderPut Pad into the box.As shown in the figure, place the Modules bundled by shielding bag in the box.After sealing the box, attach Packing Label on the attach position sign area of the box.Place a cover on the top of the box.SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 22 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.13.2 Packing Note Box Dimension: 333mm(W)X 365mm(L)X 455(D) Package Quantity in one Box: 7pcs 13.3 Box label Label Size: 108 mm (L) × 56 mm (W) Contents Model: HT170E01-101 Q`ty: Module Q`ty in one box Serial No.: Box Serial No. See next page for detail description. Date: Packing Date FG Code: FG Code of ProductHT170E01-101 00000000000007 2005.02.2200 Type0 0 00 0 Grade Line Year Month0 00000 ITEM-CODE Serial_noFG CODESPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 23 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.14.0 APPENDIXFigure 1. Measurement Set Up(L = 5 0 c m )Figure 2. White Luminance and Uniformity Measurement LocationsSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 24 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT Figure 3. Response Time TestingREV AISSUE DATE 05.09.16.Display dataWhite (TFT OFF) TRBlack (TFT ON)White (TFT OFF) TFOptical Response100% 90%10% 0% TimeFigure 4. Cross Modulation Test DescriptionVIEW AREA VIEW AREA(320,256) (960,256)L31(320,768) (960,768)YB (1120, 512)YA (1120,512) Cross-Talk (%) = YB - YA YAL0× 100Where: YA = Initial luminance of measured area (cd/m2) YB = Subsequent luminance of measured area (cd/m2) The location measured will be exactly the same in both patternsSPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 25 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.Figure 5. TFT-LCD Module Outline Dimensions (Front view)SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 26 OF 27 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 05.09.16.Figure 6. TFT-LCD Module Outline Dimensions (Rear view)SPEC. NUMBER S864-1240 B2003-002-B(3/3)SPEC. TITLE HT170E01-101 Product SpecificationPAGE 27 OF 27 A4(210 X 297)。
广东风华 端华片式电阻器分公司产品安全数据说明书
产品安全数据说明书MATERIAL SAFETY DATA SHEET1、产品及公司信息Product and Company Identification产品名称:厚膜网络电阻器Product Name: Thick Film Network Resistor供应商名称:广东风华高新科技股份有限公司端华片式电阻器分公司Supplier Name: Guangdong Fenghua Advanced Technology(Holding)Co.,Ltd.Duanhua Chip Resistor Branch Company地址:中国广东省肇庆市风华路18号风华电子城Address: Fenghua Electronic Industrial City,18th Fenghua Road, Zhaoqing, Guangdong, China联系电话(Tel):+86-758-6923225/6923477传真(Fax):+86-758-28656072、材料成分信息Composition/Information on Ingredients化学性质:固体,非化学品Chemical Character: Solid, not chemical productCAS编号:不适用CAS No: Not applicable化学成分Chemical Ingredients:成分Materials CAS No.Weigh % 三氧化二铝Aluminum trioxide 1344-28-1 40~45% 氧化镁Magnesium oxide 1309-48-4 0.6~0.7% 氧化钙Calcium oxide 1305-78-8 0.2~0.3% 二氧化硅Silicon dioxide 7631-86-9 1~1.5% 铅系玻璃Lead Glass 65997-18-4 <0.1% 氧化钌Ruthenium Dioxide 12036-10-1 <0.1% 钌酸铅Dilead diruthenium hexaoxide 37194-88-0 <0.1% 银Silver 7440-22-4 0.5% 钯Palladium 7440-05-3 <0.1% 环氧树脂Epoxy Resin 38891-59-7 0.1% 碳黑carbon black1333-86-4 0.8~1% 铁Iron7439-89-6 28~30% 锡Sn7440-31-55~6% 铜Cooper7440-50-8 <0.1% 无卤混合阻燃剂supplier confidentiality2~2.5% Halogen-free hybrid flame retardants环氧树脂Epoxy Resin1675-54-3 7~8 % 二氧化硅SiO214464-46-1 4~4.5% 固化剂(环氧树脂类)68459-31-4 3~4% Curing agent ( Epoxy resins )3、危害性信息Hazards Identification有害物质分类规定Hazards Material Classification:不适用Not Applicable理化特性Physical and Chemical Character:固体,非化学品Solid, not chemical product人体危害性Human Health Hazards:无危害Not Applicable环境危害性Environmental Hazards:无相关资料No relevant information found.4、急救方法First Aid Measures此类产品常态下极其稳定,无刺激性,一般不需急救。
瑞丰电子有限公司 BNB190TS-CF 产品规格书说明书
and reliability.如产品需要用在有特殊质量要求及可靠性要求的地方,请提前咨询瑞丰的销售人员以取得相关信息。
disassemble and analyzein written form.在取得瑞丰的同意前,客户不应该对产品进行拆解分析,如发现失效产品,请直接书面通知瑞丰。
RF-BNB190TS-CFFeatures 特征Extremely wide viewing angle.发光角度大Suitable for all SMT assembly and solder process.适用于所有的SMT组装和焊接工艺 Moisture sensitivity level:Level3.防潮等级Level3Package:4000pcs/reel.包装每卷4000pcsRoHS compliant.满足RoHS要求Description描述The Colour LED which was fabricated by using a blue chip该产品为蓝光LED,是由蓝光芯片封装形成Applications应用Optical indicator.光学指示Switch and Symbol,Display.开关和标识、显示器等General use.其他应用Package Dimension 外观尺寸NOTES:1.All dimensions units are millimeters.(所有尺寸标注单位为毫米)2.All dimensions tolerances are 0.2mm unless otherwise noted.(除特别标注外,所有尺寸公差为±0.2毫米)Electrical/Optical Characteristics at Ts=25°C电性与光学特性----450 Note:备注Vr=5V For test conditions.Vr=5v为测试分选条件。
GCE-2001全国产化说明书
说明除列明随产品配置的配件外,本手册包含的内容并不代表本公司的承诺,本公司保留对此手册更改的权利,且不另行通知。
对于任何因安装、使用不当而导致的直接、间接、有意或无意的损坏及隐患概不负责。
订购产品前,请向经销商详细了解产品性能是否符合您的需求。
本手册所涉及到的其他商标,其所有权为相应的产品厂家所拥有。
本手册内容受版权保护,版权所有。
未经许可,不得以机械的、电子的或其它任何方式进行复制。
温馨提示1、产品使用前,务必请仔细阅读产品说明书。
2、对未准备安装的主板,应将其保存在防静电保护袋中。
3、在从包装袋中拿主板前,应将手先置于接地金属物体上一会儿,以释放身体及手中的静电4、在使用前,宜将主板置于稳固的平面上。
5、请保持主板的干燥,散热片的开口缝槽是用于通风,避免机箱内的部件过热。
请勿将此类开口掩盖或堵塞。
6、在将主板与电源连接前,请确认电源电压值。
7、请将电源线置于不会被践踏的地方,且不要在电源线上堆置任何物件。
8、当您需连接或拔除任何设备前,须确定所有的电源线事先已被拔掉。
9、为避免人体被电击或产品被损坏,在每次对整机、板卡进行拔插或重新配置时,须先关闭交流电源或将交流电源线从电源插座中拔掉。
10、请留意手册上提到的所有注意和警告事项。
11、为避免频繁开关机对产品造成不必要的损伤,关机后,应至少等待30秒后再开机。
12、设备在使用过程中出现异常情况,请找专业人员处理。
13、请不要将本设备置于或保存在环境温度高于70℃上,否则会对设备造成伤害。
目录1.产品简介 (1)1.1概述 (1)1.2产品特点 (2)1.3产品优势 (2)1.4技术指标 (3)2.细参数说明 (4)2.1产品图片 (4)2.2 测试套板接口图片 (5)2.3 COMe外形尺寸 (6)2.4 COMe连接器接口定义 (7)1.产品简介1.1概述随着具备高性能计算能力的智能装备在诸如:工业、农业、能源、国防、医疗、交通、民生等多个领域的推广和应用,越来越多的企业将大量资源,投入到高性能计算能力的智能装备的研发和生产中。
医疗器械EMC检验的送检要求及资料说明
承诺书广东省医疗器械质量监督检验所:本公司所提供的样机、配件及文件资料(证书)全部真实有效,并与今后生产的产品相一致,若有任何不一致,本公司愿承担由此产生的一切法律责任。
公司(公章)年月日表1 样品的适用范围表2 样品的工作频率、生理模拟频率和响应时间表3样品的信息注:填写相关信息,并在符合的可选项中打 。
表4 样品的构成表5 样品的运行模式表6 样品电缆信息表7 样品骚扰源表8 样品的EMC关键元器件清单1、送检样品主机一台,附件包括产品配套使用的患者电缆、互连电缆、脚踏开关、适配器、显示器、电脑、测试软件等。
当送检产品为医疗器械附件时(如有创血压传感器、血氧探头等),企业应提供符合电磁兼容标准要求的主机和辅助设备。
2、当送检产品有覆盖型号时应提供覆盖申请,说明主检型号与覆盖型号的差异,并提供所有覆盖型号的样机。
覆盖型号差异表样式见“三、承诺书、覆盖型号差异表及产品相关资料表格”。
以下情况不允许覆盖:a.按产品种类划分,种类不同的产品不能互相覆盖;b.按产品工作原理划分,工作原理不同的产品不能互相覆盖;c.按影响产品电磁兼容性的关键件划分,关键件、印刷电路图、电气结构不同的产品不能互相覆盖;d.同一商标、同一规格型号的产品,由不同产地生产的不能互相覆盖;e.台式设备与落地式设备之间不能互相覆盖。
3、申请中文报告检验时,医疗器械注册产品标准中应包含电磁兼容性的条款信息,英文报告不需要提供。
根据国家规定不再要求企业提供注册产品标准时,企业只需提供技术要求,技术要求中应包含电磁兼容性的信息。
4、承诺书样式见“三、承诺书、覆盖型号差异表及产品相关资料表格”。
5、一般使用说明书和技术说明书合并,说明书内容中必须包含EMC相关信息的提示,详见YY0505(IEC60601-1-2)或GB/T 18268.26(IEC 61326-2-6)标准的条款要求,该部分如有疑问可与我所业务人员联系。
出具中文报告需提供中文说明书,出具英文报告需提供英文说明书。
E01-ML01D产品使用手册
nRF24L01P 无线模块E01系列本说明书可能会随着产品的不断改进有所更改,请以最新版的说明书为准成都亿佰特电子科技XX保留对本说明中所有内容的最终解释权与修改权产品概述E01系列是成都亿佰特公司标志性产品的 2.4G 无线模块, SPI 接口,目前已经稳定量产,并适用于多种应用场景。
E01系列采用挪威 Nordic 公司原装进口的 nRF24L01P 芯片,所有阻容感器件均采用进口元器件,尤其是晶体,我们使用了高精度宽温晶体,保证其工业特性。
发射功率为 20dBm 的模块内置了 PA 功率放大器与 LNA 低噪声放大器,从而提高通信稳定性,延长通信距离;发射功率为 0dBm 的模块均采用进口器件, 优秀的设计亦保证了卓越的射频性能,是追求低功耗的客户首选。
E01系列均严格遵守 FCC 、 CE 、 CCC 等国内国外设计规范,满足各项射频相关认证,满足出口要求。
目录1. 技术参数 ································································································································································································3 1.1. 通用参数 . ......................................................................................................................................... .......................................... 3 1.2. 电气参数 . ......................................................................................................................................... .......................................... 3 1.2.1发射电流 ··················································································································································································3 1.2.2. 接收电流 ··············································································································································································3 1.2.3. 关断电流 ··············································································································································································3 1.2.4. 供电电压 ··············································································································································································4 1.2.5. 通信电平 ··············································································································································································4 1.3. 射频参数 . ......................................................................................................................................... .......................................... 4 1.3.1. 发射功率 ··············································································································································································4 1.3.2. 接收灵敏度··········································································································································································4 1.3.3. 推荐工作频率 ·····································································································································································5 1.4. 实测参数 . ......................................................................................................................................... (5)1.4.1. 实测距离 (5)2. 机械特性 ································································································································································································5 2.1. 尺寸图 ........................................................................................................................................... ............................................. 5 2.1.1. E01-ML01D ·········································································································································································5 2.1.2. E01-ML01DP4 ····································································································································································6 2.1.3. E01-ML01DP5 ····································································································································································7 2.1.4. E01-ML01IPX ······································································································································································7 2.1.5. E01-ML01S ··········································································································································································8 2.1.6. E01-ML01SP2 (9)2.1.7. E01-ML01SP4 (9)3. 推荐连线图 (10)4. 注意事项 (10)5. 生产指导 ..............................................................................................................................................................................................11 5.1. 回流焊温度 ........................................................................................................................................... . (11)5.2 回流焊曲线图 . ......................................................................................................................................... .. (11)6. 常见问题 ······························································································································································································12 6.1. 通信距离很近 ........................................................................................................................................... (12)6.2. 模块易损坏 ........................................................................................................................................... . (12)7. 重要声明 (12)8. 关于我们 (12)1. 技术参数 1.1. 通用参数1.2. 电气参数 1.2.1. 发射电流1.2.2. 接收电流1.2.3. 关断电流1.2.4. 供电电压1.2.5. 通信电平1.3. 射频参数 1.3.1. 发射功率1.3.2. 接收灵敏度1.4. 实测参数2. 机械特性 2.1. 尺寸图 1.3.3. 推荐工作频率1.4.1. 实测距离2.1.1. E01-ML01D2.1.2. E01-ML01DP42.1.3. E01-ML01DP52.1.4. E01-ML01IPX 2.1.5. E01-ML01S2.1.6. E01-ML01SP22.1.7. E01-ML01SP4nRF24L01P 无线模块引脚序号引脚名称 1 2 3 4 5 6 7 8 VCC CE CSN SCK MOSI MISO IRQ GND ★ E01 系列用户使用手册引脚方向供电电源,必须 2.0 ~ 3.6V 之间输入输入输入输入输出输出模块控制引脚模块片选引脚,用于开始一个 SPI 通信模块 SPI 总线时钟模块 SPI 数据输入引脚模块 SPI 数据输出引脚模块中断信号输出,低电平有效地线,连接到电源参考地关于模块的引脚定义、软件驱动与通信协议详见 Nordic 官方《nRF24L01P Datasheet》★引脚用途 3. 推荐连线图序号 1 2 模块与单片机简要连接说明(上图以 STM8L 单片机为例) CE 可以长期接高电平,但是模块写寄存器时必须首先设置为 POWER DOWN 掉电模式,推荐 CE 用单片机引脚控制。
国巨电阻规格书
Approval SheetforThick Film Chip ResistorRL series1% 2% 5%YAGEO CORPORATIONFactory: No.11, Min Chuan Rd., Ta Sheh, Kaohsiung, Taiwan, R.O.C.Tel: 886-7-351-4117 Fax: 886-7-352-6475Headquarters: 3F, No.233-1, Pao Chiao Rd., Hsin Tien, Taipei, Taiwan,R.O.C.Tel: 886-2-2917-7555 Fax: 886-2-2917-4286RL Series Version 2000-3 Page-1RL SeriesVersion 2000-3 Page-21. SUBJECT : This specification describes of RL series chip resistors made of YAGEOCorporation by thick film process.2. PART NUMBER : Part number of the chip resistor is identified by the series, size,tolerance, packing style, temperature coefficient, special type and resistance value.Example :RL 1206 F R - 07 0R02Series Size Resistance Packing Temperature Special ResistanceName Code Tolerance Style Coefficient Type Valueof Resistance(1) Size : (unit: inches)0603=0.063×0.033 1210=0.122×0.102 0805=0.083×0.051 2010=0.197×0.098 1206=0.122×0.0632512=0.250×0.126(2) Tolerance : F=±1%, G=±2%, J=±5%(3) Packaging Style : R =Paper Taping Reel. K =Embossed Plastic Tape Reel. C =Bulk Cassette.(4) T .C .R.: “-“Base on Spec.(5) Special Type : 07= 7 inch Dia. Reel10=10 inch Dia. Reel 13=13 inch Dia. Reel(6) Resistance Value : 10m Ω、20 m Ω、51 m Ω、100 m Ω、330 m Ω、470 m Ω……(7) Resistance Series : E24 (E48/96 on request)RL SeriesVersion 2000-3 Page-33. MARKING :(1) RL0805/RL1206/RL1210/RL2010/RL2512Either tolerance in 5% or 1%: 4 digits, uses MIL Standard resistance marking. “R” signifies decimal place.Value =20m Ω(2) RL0603Tolerance in 5%: 3 digits, uses MIL Standard resistance marking. “R” signifies decimal place.Value =220m Ω1% Tolerance : no marking4. POWER RATING(1) Rated Power at 70°C :RL0603=1/10WRL1210=1/3W RL0805=1/8W RL2012=3/4W RL1206=1/4WRL2512=1W(2) Rated Voltage : The DC or AC (rms) continuous working voltage correspondingto the rated power is determined by the following formula : V= √(P X R)Where V= Continuous rated DC or AC (rms) working voltage (V)P= Rated power (W) R= Resistance value (Ω)5. ELECTRICAL CHARACTERISTICSSTYLE RL0603 RL0805 RL1206 Operating Temp. Range -55°C ~ +125°CDerated to 0 Load at +125°CResistance Range 100mΩ≦Rn<1Ω 20mΩ≦Rn<1Ω 10mΩ≦Rn<1ΩTemperature Coefficient ±600ppm/°C±1500ppm/°CSTYLE RL1210 RL2010 RL2512 Operating Temp. Range -55°C ~ +125°CDerated to 0 Load at +125°CResistance Range 10mΩ≦Rn<1Ω 10mΩ≦Rn<1Ω 10mΩ≦Rn<1ΩTemperature Coefficient ±1500ppm/°CRL Series Version 2000-3 Page-4RL SeriesVersion 2000-3 Page-58. ENVIRONMENTAL CHARACTERISTICS(1) Temperature Coefficient of Resistance (T.C.R.)Test Method : Measure resistance at +25°C or specified room temperature asR 1, then measure at -55°C or +125°C respectively as R 2. Determine the temperature coefficient of resistance from the following formula.R 2-R 1 `T.C.R.= ----------------- X 106(PPM/°C) R 1 (t 2-t 1)Where t 1 =+25°C or specified room temperaturet 2 = -55°C or +125°C test temperatureR 1=resistance at reference temperature in ohms. R 2=resistance at test temperature in ohms.Acceptance Standard : (Refer to item 5)(2) Thermal ShockTest Method : -55±3°C, 2 minutes and +125±2°C, 2 minutes as one cycle. After5 cycles, the specimen shall be stabilized at room temperature for 1 hour minimum and then measure the resistance to determine △R/R(%).Acceptance Standard : ±1.0%(3) Low Temperature OperationTest Method : Place the specimen in a test chamber maintained at -65 °C. After one hour stabilization at this temperature, full rated workingvoltage shall be applied 45 minutes. Have15 minutes after remove the voltage, the specimen shall be removed from the chamber and stabilized at room temperature for 24 hrs. Measure the resistance to determine △R/R(%).Acceptance Standard : ±1.0%No mechanical damage.+5+5 -0 +0+0-5+5+5-0RL SeriesVersion 2000-3 Page-6(4) Short Time OverloadTest Method : Apply 2.5 times of rated voltage but not exceeding the maximumoverload voltage for 5 seconds. Have the specimen stabilized at room temperature for 30 minutes minimum. Measure the resistance to determine △R/R(%).Acceptance Standard : ± 1.0% for 1% tolerance± 2.0% for 2~5% toleranceNo evidence of mechanical damage(5) Insulation ResistanceTest Method : Place the specimen in the jig and apply a rated continuesoverload voltage (R.C.O.V) for one minute as shown. Measure the insulation resistance.Type Voltage Type Voltage RL0603 100V RL1210 400V RL0805 300V RL2010 400V RL1206 400V RL2512 400VAcceptance Standard : ≧10000M Ω(6) Dielectric Withstand VoltageTest Method : Place the specimen in the jig and apply a specified valuecontinuous overload voltage as shown for one minute.Type Voltage TypeVoltage RL0603 100V RL1210 400V RL0805 300V RL2010 400V RL1206 400V RL2512 400VAcceptance Standard : Breakdown voltage>specification and without open/short(7) Resistance to Soldering HeatTest Method: Immerse the specimen in the solder pot at 260±5°C for 10±1seconds. Have the specimen stabilized at room temperature for30 minutes minimum.Measure the resistance to determine △R/R(%).Acceptance Standard:±1.0% & no visible damage(8) Moisture ResistanceTest Method: Place the specimen in the test chamber, and subjected to 42damp heat cycles. Each one of which consists of the steps 1 to 7as figure 1. The total length of test is 1000 hours. After the test,have the specimen stabilized at room temperature for 24 hoursand measure the resistance to determine △R/R(%).Acceptance Standard:±2.0% & no visible damageFig.1 Conditions of change of temperatureRL Series Version 2000-3 Page-7RL SeriesVersion 2000-3 Page-8(9) LifeTest Method : Place the specimen in the oven at 70±2°C. Apply the rated voltageto the specimen at the 1.5 hours on and 0.5 hour off cycle. The total length of test is 1000 hours. After the test, have the specimen stabilized at room temperature for one hour minimum and measure the △R/R(%).Acceptance Standard : ± 2.0% for 1% tolerance± 3.0% for 2~5% tolerance(10) SolderabilityTest Method : Immerse the specimen in the solder pot at 230±5°C for 5 sec.Acceptance Standard : At least 95% solder coverage on the termination.9. TAPING REELUnit :mmStyle Packaging Tape width ∅A ∅B ∅C W TRL0603 RL0805 RL1206 RL1210Paper 8mm 180+0-360+1-0 13.0±0.29.0±0.3 11.4±1RL2010 RL2512Embossed 12mm 180+0-360+1-0 13.0±0.213.0±0.3 15.4±1RL SeriesVersion 2000-3 Page-910. PAPER TAPINGUnit : mmDimensionA B W E F P0 P1 P2 ΦD0 TRL0603 1.10±0.1 1.90±0.1 0.70±0.10RL0805 1.65±0.1 2.40±0.1 0.85±0.10RL1206 1.90±0.1 3.50±0.1 0.85±0.10RL12102.80±0.13.50±0.18.0±0.2 1.75±0.13.5±0.054.0±0.14.0±0.052.0±0.051.5+0.1 -00.85±0.1011. EMBOSSED TAPINGDimensionA B W E F P0P1P2ΦD0ΦD1TRL2010 2.8±0.2 5.4±0.2RL2512 3.5±0.2 6.7±0.212.0±0.3 1.75±0.15.5±0.054.0±0.14.0±0.12.0±0.05 1.5±0.1 1.5±0.25 1.0±0.112. PACKING METHODSPAPERRL Series Version 2000-3 Page-10。
国巨电阻规格书
ELECTRICAL CHARACTERISTICS Table 2
CHARACTERISTICS POWER OPERATING TEMPERATURE RANGE MAXIMUM WORKING VOLTAGE MAXIMUM DIELECTRIC OVERLOAD WITHSTANDING VOLTAGE VOLTAGE RESISTANCE RANGE TEMPERATURE COEFFICIENT JUMPER CRITERIA
SCOPE This specification describes RC series chip resistors with lead free terminations made by thick film process. APPLICATIONS All general purpose application
CONSTRUCTION The resistor is constructed on top of a high-grade ceramic body. Internal metal electrodes are added on each end to make the contacts to the thick film resistive element. The composition of the resistive element is a noble metal imbedded into a glass and covered by a second glass to prevent environmental influences. The resistor is laser trimmed to the rated resistance value. The resistor is covered with a protective epoxy coat, finally the two external terminations (matte tin on Nibarrier) are added, as shown in Fig.4.
190产品说明书
目录产品特点 (1)工作环境 (1)技术参数 (1)产品介绍 (2)主机前面板 (2)主机后面板 (2)带铝基板LED老化台 (3)带铝基板LED老化台 (4)操作说明 (6)基本配置 (14)产品特点:恒流驱动每颗LED,单个LED之间不受影响,每台老化台相对独立,通过一台老化主机可以同时老化多种形状,大小和不同时间需求的LED。
老化系统具有强大的功能,五组可调节电流,带温度测试和频率输出功能,通过设定老化时间和脉冲冲击时间。
工作环境:工作电压:220V±10%工作温度:23℃±2℃相对湿度:10%-90%系统参数电流输出:0.5-1000mA功率:0-10W12电流分辨率:0.1mA电流精度:0.5-100mA :0.5±1%100mA-1000mA :±1%输出频率:1-3000Hz占空比:1:99-99:1定时时间:1000小时产品介绍:老化主机前面板介绍:(图一)1:左下方第一到第五组老化台的电流输出调节旋钮2:左上方为液晶显示界面,傍边分别是电源指示灯和运行指示灯3:键盘操作界面包括“电流”键、“温度”键、“频率”键、“时间”键、“*”键、“#”键和数字键。
各按键功能简介:(1)“电流”键:切换到电流显示界面;(2)“温度”键:切换到温度测量界面;(3)“频率”键:切换到频率输出界面;(4)“时间”键:切换到冲击测试界面;(5)“*”键和“#”键功能根据具体操作界面而不同,详见主机操作说明;(6)数字键:设置修改各项参数;4:右下方航空插头为温度探测器接口;5:右边红色开关为主机电源开关。
3老化主机后面板介绍(图二)1:主机电源插口2:第一组老化台电源输出口3:第二组老化台电源输出口4:第三组老化台电源输出口5:第四组老化台电源输出口6:第五组老化台电源输出口带铝基板的大功率老化台:(图三)4(图三)1:操作手柄(用来压紧或放松电源触点)2:正极定位销(调整电源触点与LED正极接触)3:负极定位销(调整电源触点与LED负极接触)4:正极触点(与LED的正极接触)5:负极触点(与LED的负极接触)6:转换器(老化带铝基板的LED不需要用转换器,转换器的位置调到与夹具持平)7:固定夹具8:负载输出线9:散热器不带铝基板的老化台(图四)5图四1:操作手柄(用来压紧或放松电源触点)2:正极定位销(调整电源触点与LED正极接触)3:负极定位销(调整电源触点与LED负极接触)4:正极触点(与LED的正极接触)5:负极触点(与LED的负极接触)6:转换器(转换器的位置调高)7:绝缘块(用来固定LED)8:负载输出线9:散热器67操作说明一、测试主机功能操作说明:测试前请先检查与老化台连线是否正常。
费加罗技研株式会社 EC01 气体传感器评价试验箱 操作使用说明书
1.安全注意事项2.使用注意事项3.部件名称及功能概述4.测试准备5.测试方法6.规格目次欢迎购买使用气体传感器评价试验箱(EC01),对此我们表示由衷的感谢!请在仔细阅读本操作使用说明书后正确使用本产品。
112468费加罗技研株式会社EC01(气体传感器评价试验箱)操作使用说明书(1)(2)(3)(4)1. 安全注意事项请务必遵守2. 使用注意事项本产品是一种简易型的试验箱。
使用时请仔细盖紧盖板不能留有缝隙。
如果要进行很精确的气体测试时,请选用比本产品气密性更高的试验箱。
测试时如果将类似于气体报警器这样体积较大的设备放入试验箱的话,可能因为试验箱的有效容积减少而导致气体浓度制备出现误差。
由于氨气、VOC 、有机溶剂蒸汽等吸附性很强的气体很容易吸附在试验箱的内壁之上,因此本产品不适用于这些气体的测试用途。
吸附于箱内壁的气体液化后,有可能导致试验箱内的气体浓度下降。
有必要对吸附性很强的气体进行测试时,请选用箱内壁采用了气体不容易附着材质的试验箱,或对箱内壁进行过涂层处理的试验箱。
如果已经向本试验箱内注入了吸附性很强的气体,为了在使用后去除附着的气体,请用酒精擦拭试验箱内部,然后对内部用洁净空气进行长时间换气等的妥善处置。
如果在高温、低温或极度的低湿度与高湿度的室内环境进行测试的话,气体传感器的测定值可能会受到影响。
请在测试前对各型号传感器规格进行确认。
本试验箱没有防爆设计。
请勿在对气体爆炸下限为(LEL) 50%以上浓度的可燃性气体进行测试时使用。
本试验箱无法保证绝对完全的密闭状态。
请勿在对可能危及人身安全的高浓度毒性气体进行测试时使用。
在用于对可燃性气体进行测试时请务必注意防火措施,同时试验箱向外排气时请在可以充分换气的场所进行。
而且,为确保安全,请考虑采取设置气体报警器等措施。
尤其是在用于对毒性气体进行测试的用途时,请务必在能够保证充分换气的场所进行。
另外出于安全考虑,将试验箱中的气体排出时请注意避免人员吸入的同时,请在室外或排风罩内进行操作。
HT190WG1-100 Product Specification
1.0 General Description 1.1 Introduction1.3 Application2.0 ABSOLUTE MAXIMUM RATINGSThe followings are maximum values which, if exceed, may cause faulty operation or3.0 ELECTRICAL SPECIFICATIONS 3.1Electrical Specifications4.0 OPTICAL SPECIFICATION4.1 OverviewNote :5.0INTERFACE CONNECTION.5.1 Electrical Interface Connection5.2 LVDS Interface (Tx; THC63LVDF83A or Equivalent) 5.2.1 ODD LVDS Interface5.2.2 EVEN LVDS Interface6.0 SIGNAL TIMING SPECIFICATION 6.1 The HT190WG1-100 is operated by the DE only..6.2 LVDS Rx Interface Timing ParameterThe specification of the LVDS Rx interface timing parameter is7.0 SIGNAL TIMING WAVEFORMS OF INTERFACE SIGNAL7.1 Sync Timing Waveforms7.3 Horizontal Timing Waveforms8.0 INPUT SIGNALS, BASIC DISPLAY COLORS & GRAY SCALE OF COLORS9.0 POWER SEQUENCETo prevent a latch-up or DC operation of the LCD module, the power on/off sequence10.0 MECHANICAL CHARACTERISTICS10.1 Dimensional RequirementsPRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’11.0 RELIABLITY TESTThe Reliability test items and its conditions are shown in below. <Table 6. Reliability Test Parameters > No 1 2 3 4 5 6 7 Test ItemsHigh temperature storage test Low temperature storage test High temperature & high humidity operation test High temperature operation test Low temperature operation test Thermal shock Vibration test (non-operating) Ta = 60 ℃, 240 hrs Ta = -20 ℃, 240 hrs Ta = 50 ℃, 80%RH, 240hrs Ta = 50 ℃, 240hrs Ta = 0 ℃, 240hrs Ta = -20 ℃ ↔ 60 ℃ (0.5 hr), 100 cycleFrequency Gravity / AMP Period Gravity 10 ~ 300 Hz, Sweep rate 30 min 1.5 G ±X, ±Y, ±Z 30 min Conditions50G 11msec, sine wave±X, ±Y, ±Z Once for each8Shock test (non-operating)Pulse widthDirection9Electro-static discharge test (non-operating)Air : 150 pF, 330Ω, 15 KV Contact : 150 pF, 330Ω, 8 KVSPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 21 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’12.0 HANDLING & CAUTIONS(1) Cautions when taking out the module Pick the pouch only, when taking out module from a shipping package. (2) Cautions for handling the module As the electrostatic discharges may break the LCD module, handle the LCD module with care. Peel a protection sheet off from the LCD panel surface as slowly as possible. As the LCD panel and back - light element are made from fragile glass material, impulse and pressure to the LCD module should be avoided. As the surface of the polarizer is very soft and easily scratched, use a soft dry cloth without chemicals for cleaning. Do not pull the interface connector in or out while the LCD module is operating. Put the module display side down on a flat horizontal plane. Handle connectors and cables with care. (3) Cautions for the operation When the module is operating, do not lose CLK, ENAB signals. If any one of these signals is lost, the LCD panel would be damaged. Obey the supply voltage sequence. If wrong sequence is applied, the module would be damaged. (4) Cautions for the atmosphere Dew drop atmosphere should be avoided. Do not store and/or operate the LCD module in a high temperature and/or humidity atmosphere. Storage in an electro-conductive polymer packing pouch and under relatively low temperature atmosphere is recommended. (5) Cautions for the module characteristics Do not apply fixed pattern data signal to the LCD module at product aging. Applying fixed pattern for a long time may cause image sticking. (6) Other cautions Do not disassemble and/or re-assemble LCD module. Do not re-adjust variable resistor or switch etc. When returning the module for repair or etc., Please pack the module not to be broken. We recommend to use the original shipping packages.SPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 22 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’13.0 PRODUCT SERIAL NUMBERSPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 23 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’14.0 Packing14.1 Packing OrderPut Pad into the box.After sealing the box, attach Packing Label on the attach position sign area of the box.As shown in figure, place Modules bundled shielding bag in box.the the by thePlace a cover on the top of the box.SPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 24 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’14.2 Packing Note Box Dimension : 346mm(W) × 526mm(D) × 448mm(H) Package Quantity in one Box : 5pcs 14.3 Box label Label Size : 108 mm (L) × 56 mm (W) Contents Model : HT190WG1 Q`ty : Module Q`ty in one box Serial No. : Box Serial No. See next page for detail description. Date : Packing Date FG Code : FG Code of ProductHT190WG1- ###5 2006.05.15.000000000000000 Type0 0 00 0 Grade Line Year Month0 00000 ITEM-CODE Serial_noFG CODESPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 25 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’15.0 AppendixFigure 1. Measurement Set Up(L = 50cm )Figure 2. White Luminance and Uniformity Measurement Locations (9 points)1447201296 901)11)21)31)41)51)64501)71)81)9810SPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 26 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT Figure 3. Response Time TestingDisplay data White(TFT OFF) TR Optical Response 100% 90% Black(TFT ON)REV P0ISSUE DATE May,15,06’White(TFT OFF) TF10% 0% TimeFigure 4. Cross Modulation Test DescriptionVIEW AREA VIEW AREA (480,300) (860,300)L31(480,600) (860,600)YB(720,450)YA (720,450) Cross-Talk (%) = YB - YA YAL0 × 100Where:YA = Initial luminance of measured area (cd/m2) YB = Subsequent luminance of measured area (cd/m2) The location measured will be exactly the same in both patternsSPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 27 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’Figure 5. TFT-LCD Module Outline Dimensions (Front view)SPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 28 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV P0ISSUE DATE May,15,06’Figure 6. TFT-LCD Module Outline Dimensions (Rear view)SPEC. NUMBER TD-0004484 B2005-C001-O(3/3)SPEC. TITLE HT190WG1-100 Product SpecificationPAGE 29 OF 29 A4(210 X 297)。
AEMC 品牌的测试和检测设备产品介绍说明书
Our products are backed by over 130 years of experience in test and measurementequipment, and encompass the latest international standards for quality and safety.An array ofMegohmmetersto choose fromAEMC® offers a full line ofm egohmmeters with testv oltages from 10V to 15kV,(model dependent), capableof measuring i nsulationresistances from 1000Ωto 29TΩ . These rugged,weather r esistant meters area ccurate, r eliable and built toperform. Battery, AC poweredand hand-cranked modelsa re available. MEGOHMMETERSFor all of your Insulation Testing needs...Technical Hotline: (800) 343-1391(2 Technical Assistance (800) 343-1391APPLICATIONS◆ M otors (AC and DC), transformers, cables,switchgears and electrical wiring installations◆ T est industrial commercial wiring andmotor control centers◆ A cceptance testing and preventive maintenance ◆ D omestic and industrial contracting ◆ D ielectric Absorption Ratio (DAR) andPolarization Index (PI) measurements◆ S pot reading tests◆ H igh resistance or absorption tests ◆ T imed resistance measurements ◆ L ow insulation test range for testing oldor flooded installations◆ D rying out conductors ◆ C ontinuity checks◆ C able testing (including telecom)◆ T est transformers◆ H eaters, relays, circuit breakersUnderstanding Insulation Resistance TestingWhy have an insulation testing program?A regular program of testing i nsulation resistance is strongly r ecommended to prevent electrical shocks, assure personal safety and to reduce or e liminate down time. It helps to detect deterioration of i nsulation in order to schedule repair work such as: vacuum c leaning, steamc leaning, drying and rewinding or testing newly installed conductors. It is also h elpful whene valuating the quality of the repairs before the equipment is put back into operation.What causes insulation failure?Some of the more c ommon causes of i nsulation failure include: overloading conductors, excessive heat or cold, moisture, dirt, corrosive vapors, o il, v ibration, aging and nicked wiring.What tests are used to detect insulation d eterioration?There are numerous maintenance tests for assessing i nsulation q uality. The three tests primarily used to test motors, generator and transformer insulation are: polarization index, spot reading and step voltage.What equipment is n ecessary for conducting insulation r esistance tests?◆ M egohmmeter with a timed test function ◆ Temperature indicator◆ H umidity meter (not n ecessary if equipmenttemperature is above the dew point)Four questions for selectingthe proper megohmmeterWhat is the proper v oltage range?Typically 2x equipment operating voltage up to 1000V and equal to the operating voltages above 1000V What is the desired power source? Battery, AC p owered, hand-cranked What is the resistance range of interest? M Ω, G Ω, T ΩWhat type of display is preferred?Analog (best for trend analysis), or Digital (eliminate g uesswork), or gives exact reading and shows trendModel 6555 performing an i nsulation test.Technical Assistance (800) 343-1391 Data Analysis & Reporting Software for MegohmmetersClear and easy setup from one dialog box for Model 5060.Model 5070 includes Step Function which allows programming of three different test profiles, each containing up to five voltage steps between 40 and 5100V and time per step of up to 10 hours.Four tabbed dialog boxes allow for clear and easy setup of all functions of the Model 5070, including setup for variable voltage and alarm set points, as well as step voltage tests and temperature compensation.• Print reports of all test results• Select test voltage and run tests from your computer with a simple click and execute process • Capture and display data in real-time• Retrieve data from the instrument’s memory:• Over 1500 insulation resistance measurements (model dependent)• Over 4000 resistance measurements • Display DAR and PI ratios• Plot graphs of manual and timed tests• Include your analysis comments section with the report • Store a library of setups for different a pplications • Certification of results through report generation• Free updates are available on our website Configure All Functions of: Models 1060, 5060, 5070, 6526, 6534, 6550 & 6555Run test and display text and graphical results from one dialog box.Model 5070 also displays step voltage.Test result s tatus box d isplayscomplete test results in real-timeTest voltage s election Insulation resistanced uring the test run Step voltage duringthe test runInsulation resistancewith temperature compensationTwo easy clicks(Instrument > Run Test) start test and graphs results {▲10V & 100V MegohmmetersAEMC ® offers low voltage insulation testersdesigned for both field and shop use. They are well suited for measuring the qualities of phone cables data cables and ESD Floor Testing. Measurement of AC and DC voltage, resistance, continuity, cable capacitance, cable length and AC c urrent can also be performed.MEGOHMMETER SELECTION GUIDEExpert tools for testing10kV & 15kVDigital MegohmmetersHigh-end portable instruments for measuring avariety of electrical insulation resistance values.The right tools for testing insulation safely and accurately, and are ideal for use on rotating equipment and machinery operating at 10kV or higher. They are fully automated 10,000V and 15,000V graphical insulation testers. They provide insulation measurements up to 29,000G model dependent Test results include DAR, PI, DD, Capacitance,Leakage Current, as well as programmable temperature correction of resistance readings.The 6555ability to program up to three step voltage profiles (from 40 to 10,000 or 15,000V,model dependent), eachcontaining up to ten steps. They also include three ramp profiles and three programmable test voltages in addition tothe standard fixed voltages of 500, 1000, 2500, 5000, 10,000 and 15,000V. These units have a USB interface and a data storage function, which permits storage of test results in files specific to the device under test. The included DataView software configures and runs tests directly from a PC and creates data analysis reports.IP534 (800) 343-1391Note: 1000V, 5000V, 10kV & 15kV megohmmeters offer memory storage and PC connection for report generation (model dependent).500V MegohmmetersAEMC ® offers a complete line of i nsulationtesters designed to test the quality of insulation on equipment powered from sources up to 240V using test voltages up to 500V. Both analog and digital meters are available. AC powered, b attery powered and hand-cranked models are available. Measurements can be in the M Ω, G Ω and T Ω range. Most m odels offer multi-function c apability, measuring AC/DC volts, resistance and continuity, as well as i nsulation resistance.1000V MegohmmetersAEMC ® offers a complete line of i nsulation testers designed to test the quality of insulation using 1000V test voltage (required for testing equipment powered from sources up to 480V ac ). Both a nalog and digital meters are available. AC powered,b attery powered and hand-cranked models are available. Many m odels can measure into the G Ω and T Ω range. Most m odels offer multi-function capability, m easuring AC/DC volts, r esistance andc ontinuity, as well as i nsulation resistance. Both hand-held instruments and rugged instruments built into portable cases are available.5000V MegohmmetersAEMC ® offers a complete line of i nsulation testers designed to test the quality of insulation using 5000V test voltages required for testing large motors, generators, transformers, cables andlarge rotating machinery. AC powered and battery powered models are a vailable. All models can measure into the G Ω and T Ω ranges. All models offer multifunction c apability, measuring AC/DC volts, resistance and continuity, as well as insulation resistance.10kV & 15kV MegohmmetersAEMC ® offers a complete line of safe and accuratei nsulation testers that are ideal for use on rotating equipment and machinery operating at 10kV or higher. They are the only fully automated 10,000V and 15,000V graphical insulation testers. They provide insulation measurements up to 29,000G Ω (29T Ω). Test results include DAR, PI, DD, ∆R, Capacitance, Leakage Current, as wellas programmable temperature correction of resistance readings.Models 6550 & 6555Safely & AccuratelyMODEL 6550Test Voltage 500V, 1000V, 2500V, 5000V, 10,000VInsulation Range 10kΩ to 25,000GΩOther Measurements Auto DAR, PI, DD, ∆R (ppm/V) ratiosLeakage Current 0 to 8mAVoltage Test 40 to 10kVOther Ramp and Voltage Test, Capacitance Measurement,Programmable Current Tests, Ramp & Step Test and Burn TestPower Source NiMH rechargeable batteriesDisplay Digital / AnalogCommunication DataView software/USB optically-isolated portDimensions 13.39 x 11.81 x 7.87"Weight Approx. 13.7lb (6.2kg)Catalog No. 2130.31MODEL 6555Test Voltage 500V, 1000V, 2500V, 5000V, 10,000V, 15,000VInsulation Range 10kΩ to 29,000GΩ (29TΩ)Other Measurements Auto DAR, PI, DD, ∆R (ppm/V) ratiosVoltage Step Test ModeLeakage Current 0 to 8mAVoltage Test 40 to 15kVOther Ramp and Voltage Test, Capacitance Measurement,Programmable Current Tests, Ramp & Step Test and Burn TestPower Source NiMH rechargeable batteriesDisplay Digital / AnalogCommunication DataView software / USB optically-isolated portDimensions 13.39 x 11.81 x 7.87"◆Voltage Ramp Test Mode6 Technical Assistance(800) 343-1391For Electrostatic Discharge TestingModel 65361000V Digital Model 65271000V Model 1015For Testing Motors,Pumps & TransformersModels 6522, 6524 & 6526500V & 1000V Hand-CrankedModel 6503Test Voltage 500, 1000V Insulation Range 100kΩ to 1000MΩResistance Range 1000ΩContinuity Range ±10ΩVoltage Measurement 600V Power Source Eight 1.5V AA batteries Analog Rubber housing Dimensions 6.6 x 4.2 x 2.2"1.45 lbs Catalog No. 1403.01Insulation Measurements for Electrical ComponentsModel 6534M O HET ETechnical Assistance (800) 75000V Digital/AnalogModel 50501000V Digital/Analog Models 1050 & 10605000V Digital/AnalogModel 50605000V Digital/AnalogModel 65055000V GraphicalModel 5070O HM ET ESince its creation in 1893, Chauvin Arnoux customer needs and applications. Over the years, Chauvin Arnoux product lines, i ncluding: c urrent probes, multimeters (the first multimeter patented in 1937!), ground testers, insulation testers, environmental testers and many others in the portable test instrument realm.One product line that stands out is Insulation Testers/Megohmmeters.Our megohmmeter line finds its roots in the early 1900s. Limited technology was available, so agalvanometer and a decade resistance box combined with a DC power source was used to make one of the first megohmmeters. Years later, hand-cranked technology, first using a generator, provided the test voltage. Today, similar technology is used in Model 6503 hand-cranked magnetizer, but a regulated alternator p rovides rectified test voltage and a sealed case protects the meter from the environment. Electronics set in the 1950s and 60s gave birth to e lectronic megohmmeters withelectronic amplifiers. Eventually, digital displays came to the scene, though analog meters remained due to customer habits and preference.Today, megohmmeters are digital and incorporate many intelligent features. Timers, alarms and variable test v oltages are becoming common. AEMC ® introduced a unique line of professional megohmmeters (Models 1050, 1060, 5050, 5060, 5070, 6505, 6527, 6522, 6524, 6526, 6534, 6536, 6550 & 6555) with added features, such as: memory; automated tests and results (internal c alculations of DAR, PI and other measurements); graphical displays; PC control; and, report compliant s oftware. Market feedback has been verypositive and the megohmmeters are setting new industry standards. All AEMC ® manufactured megohmmeters are designed to the latest international safety and testing standards, and are CE marked.Model 6555 Introduced in 2012First Megohmmeter AEMC ® Instruments • 15 Faraday Dr. • Dover, NH 03820 USA • (800) 343-1391•Fax(603)742-2346•E-mail:**************Export Department: +1 (603) 749-6434 x520 • Fax +1(603)742-2346•E-mail:***************© Chauvin Arnoux ®, Inc. d.b.a. AEMC ®I nstruments Call the AEMC ® Instruments Technical Assistance Hotline for immediate consultation with an applications engineer: (800) 343-1391950.BR-MEGOHM_0523 • Printed in the USA M u lt i-p u r p o s e C la m p -O n M e t e r s o tl in 00) 3-1 M E G O H M ME T E R SFor a ll of y ou r I ns ul at io n Te st in g ne ed s...ch ni l H o tl in e: (800) 343-1391.a em c.co mP O W E R Q U A L I T Y Fo r A ll Y ou r Po w er Q ua li ty N ee ds ...Te ca 0043391w w w ( Fo r a ll of yo ur G ro un d In te gr ity T es tin g ne ed s...G R O U N D R E S IS TA N C E T E S TE R S Te ch ni l H ot lin e: (8) 343-139w w w .a em c.co mTEST & MEA SUREM ENTINSTR UMEN TSVOLUM E 23WWW.AEM TECHNICA L HOTLINE : (800) 343-1391Family of ProductsTo learn more, visit 。
HT190WG1-600
1.0 General Description 1.1 Introduction1.3 Application2.0 ABSOLUTE MAXIMUM RATINGSThe followings are maximum values which, if exceed, may cause faulty operation or3.0 ELECTRICAL SPECIFICATIONS3.1Electrical Specificationsb) Max : Dot pattern2. Duration of rush current is about 2 ms and rising time of VDD3. The lamp frequency should be selected as different as possible from the horizontalsynchronous frequency and its harmonics to avoid interference, which may cause line flow on the display4. The voltage above this value should be applied to the lamps for more than 1 second to start-up. Otherwise thelamps may not be turned on.5. Calculated value for reference (V×BL4.0 OPTICAL SPECIFICATION4.1 OverviewNote :5.0INTERFACE CONNECTION.5.1 Electrical Interface Connection5.2 LVDS Interface (Tx; THC63LVDF83A or Equivalent) 5.2.1 ODD LVDS Interface5.2.2 EVEN LVDS Interface6.0 SIGNAL TIMING SPECIFICATION 6.1 The HT190WG1-600 is operated by the DE only..6.2 LVDS Rx Interface Timing ParameterThe specification of the LVDS Rx interface timing parameter is7.0 SIGNAL TIMING WAVEFORMS OF INTERFACE SIGNAL7.1 Sync Timing Waveforms7.3 Horizontal Timing Waveforms8.0 INPUT SIGNALS, BASIC DISPLAY COLORS & GRAY SCALE OF COLORS9.0 POWER SEQUENCETo prevent a latch-up or DC operation of the LCD module, the power on/off sequence10.0 MECHANICAL CHARACTERISTICS10.1 Dimensional RequirementsPRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.3111.0 RELIABLITY TESTThe Reliability test items and its conditions are shown in below. <Table 6. Reliability Test Parameters > No 1 2 3 4 5 6 7 Test ItemsHigh temperature storage test Low temperature storage test High temperature & high humidity operation test High temperature operation test Low temperature operation test Thermal shock Vibration test (non-operating) Ta = 60 ℃, 240 hrs Ta = -20 ℃, 240 hrs Ta = 50 ℃, 80%RH, 240hrs Ta = 50 ℃, 240hrs Ta = 0 ℃, 240hrs Ta = -20 ℃ ↔ 60 ℃ (0.5 hr), 100 cycleFrequency Gravity / AMP Period Gravity 10 ~ 300 Hz, Sweep rate 30 min 1.5 G ±X, ±Y, ±Z 30 min Conditions50G 11msec, sine wave±X, ±Y, ±Z Once for each8Shock test (non-operating)Pulse widthDirection9Electro-static discharge test (non-operating)Air : 150 pF, 330Ω, 15 KV Contact : 150 pF, 330Ω, 8 KVSPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 21 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.3112.0 HANDLING & CAUTIONS(1) Cautions when taking out the module Pick the pouch only, when taking out module from a shipping package. (2) Cautions for handling the module As the electrostatic discharges may break the LCD module, handle the LCD module with care. Peel a protection sheet off from the LCD panel surface as slowly as possible. As the LCD panel and back - light element are made from fragile glass material, impulse and pressure to the LCD module should be avoided. As the surface of the polarizer is very soft and easily scratched, use a soft dry cloth without chemicals for cleaning. Do not pull the interface connector in or out while the LCD module is operating. Put the module display side down on a flat horizontal plane. Handle connectors and cables with care. (3) Cautions for the operation When the module is operating, do not lose CLK, ENAB signals. If any one of these signals is lost, the LCD panel would be damaged. Obey the supply voltage sequence. If wrong sequence is applied, the module would be damaged. (4) Cautions for the atmosphere Dew drop atmosphere should be avoided. Do not store and/or operate the LCD module in a high temperature and/or humidity atmosphere. Storage in an electro-conductive polymer packing pouch and under relatively low temperature atmosphere is recommended. (5) Cautions for the module characteristics Do not apply fixed pattern data signal to the LCD module at product aging. Applying fixed pattern for a long time may cause image sticking. (6) Other cautions Do not disassemble and/or re-assemble LCD module. Do not re-adjust variable resistor or switch etc. When returning the module for repair or etc., Please pack the module not to be broken. We recommend to use the original shipping packages.SPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 22 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.3113.0 PRODUCT SERIAL NUMBERHT190WG1-600SPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 23 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.3114.0 Packing14.1 Packing OrderPut Pad into the box.After sealing the box, attach Packing Label on the attach position sign area of the box.As shown in figure, place Modules bundled shielding bag in box.the the by thePlace a cover on the top of the box.SPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 24 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.3114.2 Packing Note Box Dimension : 346mm(W) × 526mm(D) × 448mm(H) Package Quantity in one Box : 7pcs 14.3 Box label Label Size : 108 mm (L) × 56 mm (W) Contents Model : HT190WG1 Q`ty : Module Q`ty in one box Serial No. : Box Serial No. See next page for detail description. Date : Packing Date FG Code : FG Code of ProductHT190WG1- 6007 2007.10.30.0000000000000XXXX00 Type0 0 00 0 Grade Line Year Month0 00000 ITEM-CODE Serial_no FG CODESPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 25 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.3115.0 AppendixFigure 1. Measurement Set Up(L = 5 0 c m )Figure 2. White Luminance and Uniformity Measurement Locations (9 points)1447201296 901)11)21)31)41)51)64501)71)81)9810SPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 26 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT Figure 3. Response Time TestingDisplay data White(TFT OFF) TR Optical Response 100% 90% Black(TFT ON)REV AISSUE DATE 2008.4.31White(TFT OFF) TF10% 0% TimeFigure 4. Cross Modulation Test DescriptionVIEW AREA VIEW AREA (480,300) (860,300)L31(480,600) (860,600)YB(720,450)YA (720,450) Cross-Talk (%) = YB - YA YAL0 × 100Where:YA = Initial luminance of measured area (cd/m2) YB = Subsequent luminance of measured area (cd/m2) The location measured will be exactly the same in both patternsSPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 27 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.31Figure 5. TFT-LCD Module Outline Dimensions (Front view)SPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 28 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV AISSUE DATE 2008.4.31Figure 6. TFT-LCD Module Outline Dimensions (Rear view)SPEC. NUMBER s864-5019 B2006-5006-0 (3/3)SPEC. TITLE HT190WG1-600 Product SpecificationPAGE 29 OF 29 A4(210 X 297)。
产品规格书 1.0 连接器规格书说明书
制 订Edit审 核Check批 准ApprovalPage 1 of 7NO.: PS0020顾客产品名称型号Client Product Name: 产品名称型号Product Name: 1.0连接器 产品编码Part Number: 规格书版本号Version Number: 0产品规格书PRODUCT SPECIFICATION编号Serial numberPS0020 版本号Version Number产品名称Product Name 1.0连接器产品规格书Product Specification产品编码Part Number1 适用范围Scope本产品规格书适用于乐清市杰渝电子有限公司生产的1.0电子连接器。
This product specification covers the requirements for. 1.0 connector, which is designed and manufactured by YUEQING JIEYU ELECTRONICS Co.,LTD.2 相关标准Related Standards以下参考文件是本规格书的一个组成部份。
若本规格书中的要求与产品图纸发生冲突,则产品图中的要求为优先;若本规格书中的要求与参考文件中的要求冲突,则本规格书为优先。
The following documents form a part of this specification. In the event of conflict between the requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence.GB/T 2421 电工电子产品环境试验T esting method for Environmental of Electrical ConnectorsGB/T 2423 电工电子产品环境试验T esting method for Environmental of Electrical ConnectorsGB 2424电工电子产品基本环境试验规程T esting method for Environmental of Electrical ConnectorsGB/T 5095电子设备用机电元件基本试验规程及测量方法T esting procedure/method for components of electric equipment3 产品简图&PCB布线图Product Drawing & PCB Lay out19.0 20.35 18.0 19.35 17.0 18.35 16.0 17.35 15.0 16.35磷铜镀锡Tin/platedQuantity材料Material备注Remark编号Serial numberPS0020 版本号Version Number产品名称Product Name 1.0连接器产品规格书Product Specification产品编码Part Number5 产品性能Performance5.1机械性能Mechanical序号No.项目Item 测试条件Test Condition 规格Requirement5.1.1外观Appearance目测Checking by eye视力:1.0以上Eyesight: > 1.0照明:(200~300)lxLamp: (200~300)lx目测距离:(0.3~0.5)mSpace: (0.3~0.5)m1塑料件表面应无明显疤痕、凹陷、开裂及影响使用的变形。
HVB190S中文资料
Ordering Information
Type No. HVB190S Laser Mark H9 Package Code CMPAK
Pin Arrangement
3 1. Cathode 2. Anode 3. Cathode Anode
2 1 (Top View)
Rev.1.00 Dec 20, 2004 page 1 of 4
1.0
10
100
1.0 -4 10
10-3
10-2
10-1
Reverse voltage VR (V) Fig.3 Capacitance vs. Reverse voltage
Forward current IF (A) Fig.4 Forward resistance vs. Forward current
1. Absolute maximum ratings are described each unit separately.
Electrical Characteristics*1
(Ta = 25°C)
Item Forward voltage Reverse current Capacitance Forward resistance 2 ESD-Capability * Symbol VF IR C rf Min — — — — 200 Typ — — — 3.0 Max 1.0 100 0.35 5.0 Unit V nA pF Ω V Test Condition IF = 50 mA VR = 50 V VR = 50 V, f = 1 MHz IF = 10 mA, f = 100 MHz C = 200 pF, Both forward and reverse direction 1 pulse
G190ETN01.2友达19寸宽温工控液晶屏-杭州旭虹科技有限公司
22
Update 9. Label and Packing
24
Update 10. Outline Drawing
document version 1.0
3/25
Product Specification
AU OPTRONICS CORPORATION
G190ETN01.2
1. Handling Precautions
Product Specification
AU OPTRONICS CORPORATION
G190ETN01.2
() Preliminary Specification (V) Final Specification
Module Model Name
19” SXGA TFT-LCD Module G190ETN01.2
New Description
1.0 2014/04/07 5
Update Power Consumption and Weight
6ห้องสมุดไป่ตู้
Update 2.2 Optical Characteristics
10
Update 4.2 Absolute Ratings of Environment
13
Update 5.1.3 Backlight Unit
Customer
Date
Checked & Approved by
Vito Huang
Date
2014/04/07
Approved by
Prepared by
Date
Vivian Huang
2014/04/04
Note: This Specification is subject to change without notice.
易混合型粘合剂HT 180 树脂 化学品安全技术说明书
液体。
化学品安全技术说明书产品类型:易混合型粘合剂 HT 180 树脂化学品的推荐用途和限制用途安全技术说明书根据 GB/ T 16483-2008 和 GB/ T 17519-2013产品代码:106541GHS product identifier :Easy-Mix HT 180 Epoxy Adhesive Resin 应急咨询电话:企业标识:WEICON GmbH & Co. KG Königsberger Str. 25548157 Münster GermanyPhone: +49 251 93220Fax: +49(0)251 / 9322 - 244Internet: www.weicon.de **************:本安全技术说明书责任人的e-mail地址************/4001206011皮肤腐蚀/刺激 - 类别 1B 严重眼损伤/眼刺激 - 类别 1皮肤致敏物 - 类别 1致癌性 - 类别 2GHS危险性类别:象形图:标签要素物质或混合物的分类根据 GB13690-2009 和 GB30000-2013紧急情况概述液体。
棕褐色胺类。
如接触到或有疑虑: 求医要么就诊。
如误吸入: 立即呼叫解毒中心/医生。
如误吞咽: 立即呼叫解毒中心/医生。
如皮肤(或头发)沾染: 立即呼叫解毒中心/医生。
如发生皮肤刺激或皮疹: 求医要么就诊。
如进入眼睛: 立即呼叫解毒中心/医生。
有关环境保护措施,请参阅第 12 节。
H314 - 造成严重皮肤灼伤和眼损伤。
H317 - 可能造成皮肤过敏反应。
H318 - 造成严重眼损伤。
H351 - 怀疑致癌。
危险性说明:H314 - 造成严重皮肤灼伤和眼损伤。
H317 - 可能造成皮肤过敏反应。
H318 - 造成严重眼损伤。
H351 - 怀疑致癌。
防范说明预防措施:P280 - 穿保护性護手套和保护性衣服和眼睛防護具或面部防護具。
E-101主要参数
设备类别固定式压力容器压力容器品种换热压力容器产品名称反应生成油与混氢原料换热器产品编号Ⅲ3482A-00/1125X设备代码21201064120110066 压力容器类别Ⅲ产品标准GB151-1999 设计使用年限20年主要参数容器容积6.22/5.1m3 容器内径1500mm容器高(长)9105mm材料壳体12Cr2Mo1R厚度壳体70mm 壳体重量77799Kg 封头12Cr2Mo1R(H)封头43mm 内件重量/ Kg 内衬/内衬/ 充装重量/ Kg 夹套/夹套/设计压力壳程11.2 MPa设计温度壳程425℃最高工作压力壳程/ MPa 管程14MPa管程405℃管程/ MPa 夹套/ MPa夹套/℃夹套/ MPa 壳程介质反应生成油管程介质混氢原料夹套介质/结构形式主体结构形式单层安装型式卧式支座型式支座保温绝热方式硅酸铝检验试验无损检测方法射线、超声、磁粉无损检测比例100%耐压试验种类水压试验耐压试验压力11.2/19.13MPa 泄漏试验种类/ 泄漏实验压力/热处理种类终退热处理温度690±14℃。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
PROPRIETARY NOTE THIS SPECIFICATION IS THE PROPERTY OF BOE TFT-LCD SBU AND SHALL NOT BE REPRODUCED OR COPIED WITHOUT THE WRITTEN PERMISSION OF BOE TFTLCD SBU AND MUST BE RETURNED TO BOE HYDIS UPON ITS REQUESTTITLE : HT190E01-100 Product Specification Rev. 0BOE TFT-LCD SBU BEIJING BOE OPTOELECTRONICS TECHNOLOGY BOE HYDIS TECHNOLOGYSPEC. NUMBER S864-1221 B2005-C001-O(1/3)PRODUCT GROUP TFT-LCDREV. 0ISSUE DATE 2005.04.22.PAGE 1 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.REVISION HISTORYREV. 0 ECN NO. DESCRIPTION OF CHANGES Initial Release DATE 05.04.22. PREPARED W.K. ChangSPEC. NUMBER S864-1221 B2005-C001-O(2/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 2 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.ContentsNo. 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 General Description Absolute Maximum Ratings Electrical specifications Optical specifications Interface Connection Signal Timing Specifications Signal Timing waveforms of Interface Signal Input Signals, Display Colors & Gray Scale of Colors Power Sequence Mechanical Characteristics Reliability Test Handling & Cautions Product Serial Number Packing Appendix Item Page 4 6 7 8 10 14 16 18 19 20 21 22 23 24 26SPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 3 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.1.0 GENERAL DESCRIPTION1.1 Introduction HT190E01-100 is a color active matrix TFT LCD module using amorphous silicon TFT's (Thin Film Transistors) as an active switching devices. This module has a 19.0 inch diagonally measured active area with SXGA resolutions (1280 horizontal by 1024 vertical pixel array). Each pixel is divided into RED, GREEN, BLUE dots which are arranged in vertical stripe and this module can display 16,194,227 colors. The TFT-LCD panel used for this module is adapted for a low reflection and higher color type.CN21 CN22LVDS Input SignalConnector (CN 1 )LVDS Rx + T/CON + mini-LVDS TxSource DriverGate DriverVDDDC/DC Gamma VcomTFT LCD Panel 1280 ×1024CN23 CN241.2 Features LVDS Interface with 2 pixel / clock High-speed response Low power consumption 6-bit (FRC) color depth, display 16,194,227 colors Incorporated edge type back-light (Four lamps) High luminance and contrast ratio, low reflection and wide viewing angle DE (Data Enable) & H-Sync & V-Sync mode RoHS CompliantSPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 4 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCT 1.3 Application Desktop Type of PC & Workstation Use Slim-Size Display for Stand-alone Monitor Display Terminals for Control System Monitors for Process ControllerREV 0ISSUE DATE 2005.04.22.1.4 General Specification The followings are general specifications at the model HT190E01-100. <Table 1. General Specifications> Parameter Active area Number of pixels Pixel pitch Pixel arrangement Display colors Display mode Dimensional outline Weight Surface Treatment Back-light Specification 376.32(H) * 301.06(V) 1280(H) ×1024(V) 0.294(H) ×0.294(V) RGB Vertical stripe 16,194,227 Normally White 396.0(H) × 324.0(V) × 16.5(D) typ. 2150 (max.) Haze 25%, 3H Top/Bottom edge side, 4-CCFL type mm g colors Unit mm pixels mmRemarksSPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 5 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.2.0 ABSOLUTE MAXIMUM RATINGSThe followings are maximum values which, if exceed, may cause faulty operation or damage to the unit. The operational and non-operational maximum voltage and current values are listed in Table 2. < Table 2. Absolute Maximum Ratings>Symbol Parameter Power Supply Voltage Logic Supply Voltage Back-light Lamp Current Back-light Lamp frequency Operating Temperature Storage Temperature VDD VIN IBL FL TOP TST VSS-0.5 VSS-0.3 3 30 0 -20 6.5 VDD+0.3 8 80 +50 +60 V V mA kHz ℃ ℃ 1) 1) Ta = 25 ℃ Min. Max. Unit [VSS=GND=0V] RemarksNote : 1) Temperature and relative humidity range are shown in the figure below. Wet bulb temperature should be 39 OC max. and no condensation of water.100 90 80Relative Humidity (%RH)60Ope r a tin g R a n ge4020S tor a ge R a n ge5 -20 0 20 40 60 80T e mpe r a tu r e (˚C)SPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 6 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.3.0 ELECTRICAL SPECIFICATIONS3.1Electrical Specifications< Table 3. Electrical specifications >Parameter Power Supply Voltage Power Supply Current Permissible Input Ripple Voltage High Level Differential Input Threshold Voltage Low Level Differential Input Threshold Voltage Back-light Lamp Voltage Back-light Lamp Current Back-light Lamp operating Frequency Lamp Start Voltage 1700 Lamp Life PD Power Consumption PBL Ptotal 50000 3.0 18.6 21.6 23.1 4.5 VDD IDD VRF VIH VIL VBL IBL FL -100 610 3.0 30 620 7.5 770 8.0 70 1400 Min. 4.5 Typ. 5.0 600 Max. 5.5 900 100 +100 Unit V Note1 mA mV mV Vcm = 1.2V typ. mV Vrms mArms KHz Vrms Vrms Hrs W W W IBL=7.5mA, Note 4 Note 2 25℃, Note 3 0℃, Note 3 IBL= 8.0mA VDD = 5.0V [Ta =25±2 ℃] RemarksNotes : 1. The supply voltage is measured and specified at the interface connector of LCM. The current draw and power consumption specified is for VDD=5.0V, Frame rate=75Hz and Clock frequency = 67.5MHz. Test Pattern of power supply current a) Typ : Color Bar pattern b) Max : Vertical 2 line pattern 2. The lamp frequency should be selected as different as possible from the horizontal synchronous frequency and its harmonics to avoid interference, which may cause line flow on the display 3. The voltage above this value should be applied to the lamps for more than 3 second to start-up. Otherwise the lamps may not be turned on. 4. Calculated value for reference (VBL × IBL) ×4 excluding inverter loss.SPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 7 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.4.0 OPTICAL SPECIFICATION4.1 OverviewThe test of Optical specifications shall be measured in a dark room (ambient luminance ≤ 1 lux and temperature = 25±2℃) with the equipment of Luminance meter system (Goniometer system and TOPCONE BM-5) and test unit shall be located at an approximate distance 50cm from the LCD surface at a viewing angle of θ and Φ equal to 0°. We refer to θØ=0 (=θ3 ) as the 3 o’clock direction (the “right”), θØ=90 (= θ12 ) as the 12 o’clock direction (“upward”), θØ=180 (= θ9 ) as the 9 o’clock direction (“left”) and θØ=270(= θ6 ) as the 6 o’clock direction (“bottom”). While scanning θ and/or Ø, the center of the measuring spot on the Display surface shall stay fixed. The measurement shall be executed after 30 minutes warm-up period. VDD shall be 5.0V +/-10% at 25°C. Optimum viewing angle direction is 6 ’clock.4.2 Optical Specifications[VDD = 5.0V, Frame rate = 60Hz, Clock = 54MHz, IBL = 7.5mA, Ta =25±2 ℃] ParameterHorizontal Viewing Angle range Vertical Luminance Contrast ratio Luminance of White White luminance uniformity WhiteSymbolΘ3 Θ9 Θ12 Θ6 CR Yw ΔY Wx Wy Rx RedConditionMin.65 65Typ.75 75 75 60 700 300 80 0.313 0.329 0.639 0.339 0.279 0.601 0.141 0.078 8Max.-UnitDeg. Deg. Deg. Deg.RemarkNote 1CR > 10 65 50 550 250 75 0.283 0.299 0.609 Θ = 0° (Center) Normal Viewing Angle 0.309 0.249 0.571 0.111 0.048Note 2 cd/m2 % 0.343 0.359 0.669 0.369 Note 5 0.309 0.631 0.171 0.108 12 2.0 ms % Note 6 Note 7 Note 3 Note 4Reproduction of color Green BlueRy Gx Gy Bx ByResponse Time Cross TalkRise DecayTr Td CT --SPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 8 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.Note :1. Viewing angle is the angle at which the contrast ratio is greater than 10. The viewing are determined for the horizontal or 3, 9 o’clock direction and the vertical or 6, 12 o’clock direction with respect to the optical axis which is normal to the LCD surface. Contrast measurements shall be made at viewing angle of θ= 0° and at the center of the LCD surface. Luminance shall be measured with all pixels in the view field set first to white, then to the dark (black) state. (See FIGURE 1 shown in Appendix) Luminance Contrast Ratio (CR) is defined mathematically. CR 3. = Luminance when displaying a white raster Luminance when displaying a black raster2.4.5.6.7.Center Luminance of white is defined as the LCD surface. Luminance shall be measured with all pixels in the view field set first to white. This measurement shall be taken at the locations shown in FIGURE 2 for a total of the measurements per display. The White luminance uniformity on LCD surface is then expressed as : ΔY = ( Minimum Luminance of 9points / Maximum Luminance of 9points ) * 100 (See FIGURE 2 shown in Appendix). The color chromaticity coordinates specified in Table 4. shall be calculated from the spectral data measured with all pixels first in red, green, blue and white. Measurements shall be made at the center of the panel. The electro-optical response time measurements shall be made as FIGURE 3 shown in Appendix by switching the “data” input signal ON and OFF. The times needed for the luminance to change from 10% to 90% is Td, and 90% to 10% is Tr. Cross-Talk of one area of the LCD surface by another shall be measured by comparing the luminance (YA) of a 25mm diameter area, with all display pixels set to a gray level, to the luminance (YB) of that same area when any adjacent area is driven dark. (See FIGURE 4 shown in Appendix).SPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 9 OF 29 A4(210 X 297)PRODUCT GROUPTFT- LCD PRODUCTREV 0ISSUE DATE 2005.04.22.5.0●INTERFACE CONNECTION.CN11 Module Side Connector : JAE FI-XB30SSRL-HF16 or Equivalent User Side Connector : JAE FI-X30H or EquivalentSymbol RXO0RXO0+ RXO1RXO1+ RXO2RXO2+ GND RXOCLKRXOCLK+ RXO3RXO3+ RXE0RXE0+ GND RXE1RXE1+ GND RXE2RXE2+ RXECLKRXECLK+ RXE3RXE3+ GND NC DE NC VDD VDD VDD Function LVDS ODD 0- SIGNAL LVDS ODD 0+ SIGNAL LVDS ODD 1- SIGNAL LVDS ODD 1+ SIGNAL LVDS ODD 2- SIGNAL LVDS ODD 2+ SIGNAL GROUND LVDS ODD CLOCK- SIGNAL LVDS ODD CLOCK+ SIGNAL LVDS ODD 3- SIGNAL LVDS ODD 3+ SIGNAL LVDS EVEN 0- SIGNAL LVDS EVEN 0+ SIGNAL GROUND LVDS EVEN 1- SIGNAL LVDS EVEN 1+ SIGNAL GROUND LVDS EVEN 2- SIGNAL LVDS EVEN 2+ SIGNAL LVDS EVEN CLOCK- SIGNAL LVDS EVEN CLOCK+ SIGNAL LVDS EVEN 3- SIGNAL LVDS EVEN 3+ SIGNAL GROUND NO CONNECTION NO CONNECTION NO CONNECTION POWER SUPPLY ( +5.0 V ) Remark5.1 Electrical Interface ConnectionPin No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30SPEC. NUMBER S864-1221 B2005-C001-O(3/3)SPEC. TITLE HT190E01-100 Product SpecificationPAGE 10 OF 29 A4(210 X 297)5.2 LVDS Interface (Tx; THC63LVDF83A or Equivalent)5.2.1 ODD LVDS InterfaceTransmitter InterfaceFI-XB30SSRL-HF16Pin No.System (Tx)TFT-LCD (Rx)Pin No.12345689484710114645RXO0-RXO0+RXO1-RXO1+RXO2-RXO2+RXO CLK-RXO CLK+424140393837RXO3-RXO3+OUT0-OUT0+OUT1-OUT1+OUT2-OUT2+CLK OUT-CLK OUT+OUT3-OUT3+Pin No.5152545556346711121415192022232427283031502810161825RemarkInput Signal OR0OR1OR2OR3OR4OR5OG0OG1OG2OG3OG4OG5OB0OB1OB2OB3OB4OB5Hsync Vsync DE MCLK OR6OR7OG6OG7OB6OB7RSVDO D D L V D S5.2.2 EVEN LVDS InterfaceTransmitter InterfaceFI-XB30SSRL-HF16Pin No.System (Tx)TFT-LCD (Rx)Pin No.1213151618192021484722234645RXE0-RXE0+RXE1-RXE1+RXE2-RXE2+RXE CLK-RXE CLK+424140393837RXE3-RXE3+OUT0-OUT0+OUT1-OUT1+OUT2-OUT2+CLK OUT-CLK OUT+OUT3-OUT3+Pin No.5152545556346711121415192022232427283031502810161825RemarkInput Signal ER0ER1ER2ER3ER4ER5EG0EG1EG2EG3EG4EG5EB0EB1EB2EB3EB4EB5Hsync Vsync DE MCLK ER6ER7EG6EG7EB6EB7RSVDE V E N L V D S5.4 Back-light Interface Connection●CN 21,22,23,24Module Side Connector :35001HS-02L(YeonHo) or Equivalent User Side Connector:35001HS-02L(YeonHo) or EquivalentPIN NO.INPUT COLOR FUNCTION 1HOT Pink & Blue High Voltage 2COLDBlack & WhiteGround5.3 Data Input Format(1280, 1024)(1279,1024)(2,1024)(1,1024)BG R B G R B G R B G R 1 Pixel = 3 DotsR (1280,1)G R (1279,1)BR B R EVEN (2,1)B G B G B G R G ODD (1,1)Display Position of Input Data (V-H)6.0 SIGNAL TIMING SPECIFICATION6.1 The HT190E01-100 is operated by the DE & H-Sync & V-Sync mode ( LVDS Transmitter Input )Item Symbols Min Typ Max Unit Frequency1/Tc 405468MHz High Time T65--ns Low TimeT75--ns Setup time T84--ns Hold timeT94--ns Data Enable Setup TimeTes 4--ns 103210661536lines Vertical Display Period Tyd -1024-lines One line Scanning Period T36728441022clocks Horizontal Display PeriodT4640640640clocksFrame Period Ty 13.3316.67-ms DataClock6.2 LVDS Rx Interface Timing ParameterThe specification of the LVDS Rx interface timing parameter is shown in Table 4.<Table 4. LVDS Rx Interface Timing Specification>Item Symbol Min Typ Max Unit RemarkCLKIN Period tRCIP 14.718.5-msec CLK Difference tCdiff -tRCIP*(3/7)0+tRCIP*(3/7)nsec Input Data 0tRIP1-0.40.0+0.4nsec Input Data 1tRIP0tRICP/7-0.4tRICP/7tRICP/7+0.4nsec Input Data 2tRIP6 2 ×tRICP/7-0.4 2 ×tRICP/7 2 ×tRICP/7+0.4nsec Input Data 3tRIP5 3 ×tRICP/7-0.4 3 ×tRICP/7 3 ×tRICP/7+0.4nsec Input Data 4tRIP4 4 ×tRICP/7-0.4 4 ×tRICP/7 4 ×tRICP/7+0.4nsec Input Data 5tRIP3 5 ×tRICP/7-0.4 5 ×tRICP/7 5 ×tRICP/7+0.4nsec Input Data 6tRIP26 ×tRICP/7-0.46 ×tRICP/76 ×tRICP/7+0.4nsectRIP3tRIP4tRIP5tRIP6tRIP2tRIP0tRIP1Rx2Rx1Rx0Rx6Rx5Rx4Rx3Rx2Rx1Rx0Rx3tRCIPVdiff=0[v]Vdiff=0[v]RxOCLKIN+RXO/Ez +/-* Z = 0, 1, 2,3 RxECLKIN+tCdiff* Vdiff = (RXO/Ez+)-(RXO/Ez-),…. ,(RXO/ECLK+)-(RXO/ECLK-)7.0 SIGNAL TIMING WAVEFORMS OF INTERFACE SIGNAL7.1 Sync Timing Waveforms7.2 Horizontal Timing WaveformsV-SyncH-SyncDEOver 2 H-syncFix H-Sync width Area1) Need over 2 H-sync during V-Sync Low ( Recommend : over 3 H-Sync )2) Fix H-Sync width from V-Sync falling edge to first rising edgeMCLKDEx,1x,2x,yx+1,1x,1024Invalid Data Data Invalid ThTvTvdR7 ~ R0G7 ~ G0B7 ~ B07.3 Horizontal Timing WaveformsMCLKDED1D2DnData D1D2D3Invalid D638D639D640ThThdTcRA7 ~RA0GA7 ~GA0BA7 ~BA0TchTclTdh Tds2.0V0.8V2.0V 0.8V Tes2.0VMCLKValid DataDataDE1.5V8.0 INPUT SIGNALS, BASIC DISPLAY COLORS & GRAY SCALE OF COLORSRED DATA GREEN DATABLUE DATA R7R6R5R4R3G6G5G4G3G2G1G0B6B5B4B3B2B1B0Black 000000000000000000000000Blue 000000000000000011111111Green 000000001111111100000000Cyan 000000001111111111111111Red 111111110000000000000000Magenta 111111110000000011111111Yellow 111111111111111100000000White 111111111111111111111111Black 000000000000000000000000△000000000000000100000000Darker 000000000000001000000000△↑↑↑▽↓↓↓Brighter 000000001111110100000000▽000000001111111000000000Green 000000001111111100000000Gray Scale of GREENBlack 000000000000000000000000△000000000000000000000001Darker 000000000000000000000010△↑↑↑▽↓↓↓Brighter 000000000000000011111101▽000000000000000011111110Blue 000000000000000011111111Gray Scale of BLUEBasic ColorsBlack 000000000000000000000000△000000010000000000000000Darker 000000100000000000000000△↑↑↑▽↓↓↓Brighter 111111010000000000000000▽111111100000000000000000Red 111111110000000000000000Gray Scale of RED0△000000010000000100000001Darker 000000100000001000000010△↑↑↑▽↓↓↓Brighter 111111011111110111111101▽111111101111111011111101White11111111111111111111111100000000000000000R2R1R00G7B700Black 000Gray Scale of WHITEColor & Gray Scale9.0 POWER SEQUENCETo prevent a latch-up or DC operation of the LCD module, the power on/off sequence shall be as shown in belowT1Power SupplyInterface SignalBack-lightValidT2T5T3T40.9VDD0.1VDD0.9VDD0.1VDD0V0V0VT6Notes:1. When the power supply VDD is 0V, Keep the level of input signals onthe low or keep high impedance.2. Do not keep the interface signal high impedance when power is on.Back Light must be turn on after power for logic and interface signal are valid.●T1 ≤10 ms●0 ≤T2 ≤50 ms ●200ms ≤T3●200ms ≤T4●0 ≤T5 ≤50ms ●1sec ≤T610.0 MECHANICAL CHARACTERISTICS10.1 Dimensional RequirementsFIGURE 6 (located in Appendix) shows mechanical outlines for the model HT190E01-100.Other parameters are shown in Table 5.<Table 5. Dimensional Parameters>Parameter Specification Unit Dimensional outline396.0 ×324.0×16.5 mmWeight 2150 (max.)gramActive area 376.32(H) * 301.06(V)mmPixel pitch 0.294(H) ×0.294(V)mmNumber of pixels 1280(H) ×1024(V) (1 pixel = R + G + B dots)pixelsBack-light Top / Bottom edge side 4-CCFL type10.2 MountingSee FIGURE 5. (shown in Appendix)10.3 Anti-Glare and Polarizer Hardness.The surface of the LCD has an anti-glare coating to minimize reflection and a coating to reduce scratching.10.4 Light LeakageThere shall not be visible light from the back-lighting system around the edges of the screen as seen from a distance 50cm from the screen with an overhead light level of 350lux.11.0 RELIABLITY TESTThe Reliability test items and its conditions are shown in below.<Table 6. Reliability Test Parameters >No Test ItemsConditions1High temperature storage test Ta = 60 ℃, 240 hrs 2Low temperature storage test Ta = -20 ℃, 240 hrs 3High temperature & high humidity operation testTa = 50 ℃, 80%RH, 240hrs 4High temperature operation test Ta = 50 ℃, 240hrs 5Low temperature operation test Ta = 0 ℃, 240hrs6Thermal shock Ta = -20 ℃↔60 ℃(0.5 hr), 100 cycleFrequency 10 ~ 300 Hz, Sweep rate 30 min Gravity / AMP 1.5 G±X, ±Y, ±Z 30 min Gravity50G11msec, sine wave±X, ±Y, ±Z Once for eachPulse width8Shock test(non-operating)Period Direction9Electro-static discharge test (non-operating)Air : 150 pF, 330Ω, 15 KV Contact : 150 pF, 330Ω, 8 KV7Vibration test (non-operating)12.0 HANDLING & CAUTIONS(1) Cautions when taking out the moduley Pick the pouch only, when taking out module from a shipping package.(2) Cautions for handling the moduley As the electrostatic discharges may break the LCD module, handle the LCDmodule with care. Peel a protection sheet off from the LCD panel surface asslowly as possible.y As the LCD panel and back -light element are made from fragile glass material,impulse and pressure to the LCD module should be avoided.y As the surface of the polarizer is very soft and easily scratched, use a soft drycloth without chemicals for cleaning.y Do not pull the interface connector in or out while the LCD module is operating.y Put the module display side down on a flat horizontal plane.y Handle connectors and cables with care.(3) Cautions for the operationy When the module is operating, do not lose CLK, ENAB signals. If any one ofthese signals is lost, the LCD panel would be damaged.y Obey the supply voltage sequence. If wrong sequence is applied,the modulewould be damaged.(4) Cautions for the atmospherey Dew drop atmosphere should be avoided.y Do not store and/or operate the LCD module in a high temperature and/orhumidity atmosphere. Storage in an electro-conductive polymer packing pouchand under relatively low temperature atmosphere is recommended.(5) Cautions for the module characteristicsy Do not apply fixed pattern data signal to the LCD module at product aging.y Applying fixed pattern for a long time may cause image sticking.(6) Other cautionsy Do not disassemble and/or re-assemble LCD module.y Do not re-adjust variable resistor or switch etc.y When returning the module for repair or etc., Please pack the module not to bebroken. We recommend to use the original shipping packages.13.0 PRODUCT SERIAL NUMBER14.0 Packing14.1 Packing OrderAfter sealing the box, attach Packing Label on the attach position sign area of the box.Place a cover on the top of the box.Put silica gels in the box.As shown in the figure, place the Modules bundled by shielding bag in the box.Put Pad into the box.14.2 Packing Notey Box Dimension : 346mm(W) ×526mm(D) ×448mm(H)y Package Quantity in one Box : 7pcs 14.3 Box labely Label Size : 108 mm (L) ×56 mm (W) y ContentsModel : HT190E01Q`ty : Module Q`ty in one boxSerial No. : Box Serial No. See next page for detail description.Date : Packing DateFG Code : FG Code of Product0000000000000Type Grade Line Year Month ITEM-CODE Serial_noFG CODEHT190E01-###00000000000002005.02.22.715.0 APPENDIXFigure 1. Measurement Set Up(L = 50cm) Figure 2. White Luminance and Uniformity Measurement Locations (5 points)Figure 3. Response Time TestingDisplay dataOptical ResponseBlack(TFT ON)White(TFT OFF)100%90%10%0%T RT FTimeWhite(TFT OFF)Y A(1120,512)L0Y B (1120, 512)960,256960,768320,768L31320,256Y B -Y A Y ACross-Talk (%) =×100Figure 4. Cross Modulation Test DescriptionVIEW AREAWhere:Y A = Initial luminance of measured area (cd/m 2)Y B = Subsequent luminance of measured area (cd/m 2)The location measured will be exactly the same in both patternsVIEW AREAFigure 5. TFT-LCD Module Outline Dimensions (Front view)Figure 6. TFT-LCD Module Outline Dimensions (Rear view)。