CBB电容检验标准
电容检验标准
1、适用范围Applicable Scope本规定适用于单相异步电机运转电容(C B B电容)。
This criterion applies to the running capacitor (CBB) put on the single phase asynchronous motor manufactured by Guangdong Lingxiao Pump Industry Co., ltd.2、执行标准Standard电容器必须符合IEC60252和GB3667有效版本的要求。
Capacitor must comply with the latest version IEC60252&GB3667.3、电容运行等级分级Class of Operation根据IEC60252标准,电容在额定负荷、额定电压、规定温度和额定频率下的最短总寿命分为下列四个等级。
As stipulated in IEC60252, the minimum total life for which the capacitor has been designed at rated duty, voltage, temperature and frequency is:A级(A class)—30000h Class A-30 000hB级(B class)—10000h Class B-10 000hC级(C class)—3000h Class C- 3 000hD级(D class)—1000h Class D- 1 000h4、检验、试验设备Inspection and Testing instruments电容耐久试验综合测试系统、电容冲击测试台、500V直流充击测试台、电容测试仪、20KV A变压器、湿热箱、高压锅等。
The inspection and testing instrument listed as: Capacitor endurance general testing system, capacitor impact testing station, 500V direct current impact testing station,capacitor testing instrument, 20KV A transformer, damp heat testing case, pressure cooker etc.5、检验流程Inspection Procedure5.1.CBB60、CBB61电容检验流程CBB60, CBB61 capacitor inspection procedure:电容整体质量评估外观、标志、认证塑料外壳阻燃性(仅适用于塑料外壳)外型尺寸及引线长度线耳冲压质量或插接端子质量检验电容值和损耗角正切值测量两极间耐压试验极间与外煮水试验冲击试验耐久试验解剖检验、分析出检验报告Capacitor holistic quality evaluation→visual, marks, certification→fire resistance of the plastic shell (only applicable to plastic shell)→dimension and lead length →termination pressing quality or plug termination quality inspection→measure of capacitor value and tangent of loss angle value→voltage duration test between 2 poles→voltage duration test between pole and shell(only applicable to metal shell)→water cooking testimpact test ,duration test →anatomic inspection and analysis→testing report5.2.CBB65电容检验流程CBB65 capacitor inspection procedure:电容整体质量评估外观、标志、认证外型尺寸线耳冲压质量或插接端子质量电容值和损耗角正切值测量两极间耐压试验冲击试验耐久试验解剖检验、分析出检验报告Capacitor holistic quality evaluation→visual, marks, certification→dimension termination pressing quality→measure of capacitor value and tangent of loss angle value voltage duration test between 2 poles→voltage duration test between pole and shell(only applicable to metal shell)→ impact testduration test →anatomic inspection and analysis→testing report6、检Inspection and Testing Requirements6.1.电容试验前整体质量评估Capacitor holistic quality evaluation before test6.1.1.电容器环氧树脂封灌要求(限于CBB60、CBB61电容)Epoxy resin requirements (it is only limited to CBB60, CBB61)6.1.2.电容器的整个芯子都必须有环氧树脂密封,灌封要求按附图1示例。
电容检验规范(1)
电容检验(jiǎnyàn)规范(1)电容(diànróng)检验规范(1)物料名称电解电容物料类别电子类供应商参考《合格供应商目录》序号检验项目技术要求/缺陷内容检验方法检验工具不合格分类抽验判定检验水平1包装质量1.内外包装标示清晰明确,包括供应商名称,规格型号,批号,数量,生产日期;2.外包装应牢固,无破损,变形。
具有良好的防潮,防压及防腐蚀等。
用肉眼观察目测外观质量1.引出线应光亮、清洁,无脱锡、露铜、露铁、生锈、黑斑及明显水迹;表面无尖角毛刺、损伤、夹层、氧化现象;引出线不得有废针、弯针;2.外表无可见损伤:变形、无凹陷,无突起;没有混料的现象;用肉眼观察目测2外形尺寸1.本体长、宽,引脚直径和脚距,应与BOM要求或者零件规格书要求或者样品相符;用游标卡尺测量游标卡尺2.引脚间距要与PCB板一致。
将物料插入PCB板进行试装PCB板3电气性能容值要与物料清单规格要求一致。
在1KHz下,用电桥测试容量数字电桥4引脚强度引脚受力弯曲后,无断裂、和本体无松动或脱落,电气性能符合第3项。
任取一根引脚按相反的方向连续弯曲两次(共四次)后,用肉眼观察和电桥测试。
目测/数字电桥5安全性能耐压施加额定电压,电容本体应无弯化,各项性能参数符合《规格表》用耐压测试仪在电容两端施加125%额定电压耐压测试仪6漏电流漏电流值应满足I≤(0.03×C×U)/1000,式中C为电容量,U为额定电压,0.03为常数。
(电解电容需要测试此项)漏电流测试仪额定电压下测试漏电电流漏电流测试仪7高温测试高温试验后,外观应无可见损伤,性能符合要求。
(瓷片电容除外)放在温度105±5℃的恒温箱中超过4h后检测。
恒温箱8低温测试低温试验后,外观应无可见损伤,性能符合要求。
(瓷片电容除外)放在温度-24±5℃的冰箱中超过24h后检测。
冰箱检验要求及注意事项:附录(f ùl ù)A贴片电阻/电容(di ànr óng)规格表1.以上检验项目可参考《合格供应商项目》、《电板物料清单》、《供应商的选型手册》。
CBB61电容出厂报告500V
电 容 器 检 验 报 告
型号 CBB61 测试项目 500V 1μ F 标准值或技术要求 电容器外壳表面无明显污垢等缺陷。 外观检查 标志清晰、数据正确,外壳、引出端 和固定装置应符合图纸要求。 电容器应具有良好的密封性能,密封 密封性试验 性试验后应无渗漏,无外壳变形。 引出端之间的 电容器引出端之间应能承受2Un试验 耐压试验 电压,持续时间3s。不应发生永久性 击穿或闪络。 电容器引出端与外壳之间能承受2Un+ 引出端与外壳之 1KV,但不小于2KV的工频电压,持续 间的耐压试验 时间2s,试验期间不应发生击穿或闪 络。 电容器的实测电容与其额定电容之差 电容测量 应在额定电容的±5%范围内。 损耗角正切 电容器的损耗角正切应不大于0.0050。 ∠0.0050 合格 ±5%之内 合格 2000v 2s 通过 合格 1000v 3s 通过 合格 符合要求 合格 符合要求 合格 数量:4000只 实测值 单项判定
结论: 各项测试合格,同意出厂。 检验员:蒋振宇 品 管 部 2017年2月16日
聚酯膜电容验收操作规范
聚酯膜电容验收操作规范1. 主题:聚脂膜电容器的验收要求、项目、方法及抽样方案的规范。
2. 常规检验项目2.1 外观和标识2.1.1技术要求:外观整洁无伤痕、气泡,标识正确完整清晰、引线光洁无发黑氧化,编带无分层变形、粘接良好。
2.1.2检验方法:目测法。
2.2 尺寸2.2.1技术要求:外形尺寸、引线间距、编带尺寸和成型尺寸,应符合产品规格书所规定的图纸要求及我司相关补充EDE规定。
2.2.2检验方法:用卡尺测量与目测法结合。
2.3 包装2.3.1 技术要求:包装应符合产品规格书所规定的图纸要求及我司相关补充规定,应保证包装完好无损、耐用、编带未明显变形。
2.3.2 检验方法:目测法与试用法。
2.4 电容量和损耗角正切值tgδ2.4.1技术要求:按产品规格书所规定要求执行,注意测试频率及电压要求。
2.4.2检验方法:采用数字LCR仪测量,测量频率及电压应符合规格书要求。
2.5 耐压2.5.1技术要求:按产品规格书所规定要求执行,无特殊要求,耐压测试漏电流设置为1mA。
2.5.2检验方法:用CJ2671耐压测试仪或更高精度耐压测试仪,将规格书要求的电压按规定时间施加于电容器的引出线两端,应无击穿报警。
金属化聚脂膜电容允许耐压测试时有一小声“啪”音且仪器未显示超标报警。
3. 特殊检验项目3.1 绝缘电阻3.1.13.1.2技术要求:按技术协议或产品规格书所规定的要求执行。
3.1.3检验方法:用TH2683绝缘电阻测试仪测试,注意测试电压及下限设定应符规格书要求,容量>=100nF充电时间至少30S,容量<100nF充电时间至少15S,测试完请按“放电”钮,数秒后再取下电容,如遇测试仪报警不达标,请将充电时间设定为1min为标准再进行测试。
3.2 丝印附着力3.2.1 技术要求:试验后丝印无明显残缺、难以辨认现象。
东莞德信诚精品培训课程(部分)内审员系列培训课程查看详情TS16949五大工具与QC/QA/QE品质管理类查看详情 JIT>>> qq:14259839543.2.2 检验方法:用手对丝印字体用约1Kg的力搓10次。
CBB电容真假辨别
CBB电容真假辨别
CBB电容在电路上经常被使用到,有一个人问了一个很有意思的问题,CBB电容真假辨别有什么好方法呢?这个确实不是极好回答。
首先,低电压替代高电压
如果说CBB电容做假的话,最常见的就是使用低电压的CBB电容替代高电压,比如使用额定电压400V的CBB电容冒充630V,这个辨别也极简单,只需要看电容的体积就行,同容量的电容器,一般CBB 电容的体积越小,它的真实额定电压也就越低。
其次,冒充品牌电容
有一些公司没有属于自己的品牌,它们会冒充一些大品牌的电容,把自己的CBB电容印上别上的品牌,这种不好分辨,我们建议还是从品牌厂家的渠道购买,这个更放心一些。
CBB电容
使用劣质薄膜原料生产电容
一个CBB电容质量的好坏,跟它使用的薄膜原料有核心的关系,使用优质薄膜原料和劣质薄膜原料生产出来的电容品质相差万里,这个辨别困难更大,我们的建议是:尽量不要购买中性印字的CBB电容,其次,尽量购买大品牌、好口碑的CBB电容。
最后,使用聚酯薄膜冒充CBB电容
聚酯薄膜也就是我们常说的CL电容,由于它的价格比聚丙烯薄膜要低一些,所以有一些厂家可能会使用聚酯薄膜冒充CBB电容,聚丙烯薄膜电容器稳定性和耐压性比聚酯薄膜要高,更重要是聚丙烯薄膜电容器的损耗是聚酯薄膜电容的十分之一。
用容量测试仪测损耗.1KHz条件下CBB(聚丙)损耗小,CL(聚酯,很多人叫涤纶-太不专业啦~)损耗大,大概多10倍。
如果用10KHz测就更不一样了.CBB在万分之1,2而CL就在万分之100.会大100倍.。
CBB61交流马达启动电容检验规 范
CBB61交流马达启动电容检验规范产品介绍:本电容器采用边缘加厚的金属化锌铝膜作为电极和介质。
再在ABS或PBT 立方体塑料外壳中装入阻燃环氧树脂。
本产品拥有体积小,性能高和使用寿命厂等特点。
CBB61电容器。
外观:方形、塑壳。
引出线有:普通引线(多股铜芯线);焊片(187#、250#单插或双插);CP线(插针、引脚);镀锡铜线或引线。
底耳:根据用户需要可以带底耳或不带底耳。
生产规格:公司现生产CBB61 电容具体参数如下(容量、电压、尺寸)。
以450VAC 为例:(其他:电压:220v-630V;容量:1µF-35µF;尺寸可选)额定电压(VAC)标称电容量(µF)尺寸(mm)长(L)宽(W)高(H)450V 0.8µF371727 1µF371727 1.5µF371727 3µF472234 5µF482638 8µF582644 10µF582644 16µF592949 20µF592949 30µF683451主要用途:1.CBB61电容器主要用在电风扇起动和灯具补偿。
2.空调风机、排风扇等频率为50Hz/60Hz交流电源供电功率相对较小的单相电机启动和运行。
产品第三方认证:CQC(国内市场认证);UL(美国市场认证);VDE(欧洲国家认证)技术规范:·执行标准:GB/T3667-2005·技术特性:气候类别:40/70/21或40/85/21·容量偏差:±5%·绝缘电阻:≥3000S(MΩ·µF)·损耗角正切:tgδ≤0.002(50Hz~100Hz)使用要求:·海拔:≤2000m·投入时的剩余电压:不超过额定电压的10%·最大允许电压:不超过1.1倍额定电压·最大允许电流:不超过1.3倍额定电流售后服务:产品质保三年,任何公司或个人自购买日起三年内我司承诺产品质量.注:1、其它容量、尺寸系列可按用户需要商定。
CBB电容检验标准
受控:编号:
版本:A1.0
中山品诚实业有限公司电源厂
CBB电容检验标准
编制:薛大成
审核:
批准:
编写日期:2017 年 5 月26 日实施日期:年月日
中山品诚实业有限公司电源厂电解类电容检验标准
CBB电容检验标准
1.0 来料实物CBB电容,实物型号应与订单型号,送货单型号,一致。
2.0 来料外包装应包装良好(无外箱破损),包装应有利于产品运输及储存,标识清楚,正确。
3.0 根据抽样方案,GB2828-2003正常检验Ⅱ级抽样方案,AQL允收水准,致命缺陷0.01,严重缺陷0.25,轻微缺陷1.0。
4.0 电解电容应测试电容容量(LCR),漏电流(漏电流测试仪),两项参数。
4.1 CBB电容测试参数设定,频率,选1KHZ.
4.2 实际中若频率升高而损耗增加,则应选用串联等效电路,若频率升高而损耗减小,则应选用并联等效电路,
4.3 测试前一定要进行清零。
漏电流测试,参照漏电流测试仪操作规程。
4.4 测试仪器,LCR(容量)。
5.0 检验合格,允收,外箱加盖合格印章,入库。
6.0 检验不合格时,记录不良现象,交由各部门会签评审。
处理结果以终审结果为准。
7.0 将检验结果记录于进料检验报告并存档。
文件编号:版本:A1.0 第1 页共1 页。
电容检验规范
电容检验规范更多免费资料下载请进:好好学习社区电容检验规范一、检验标准根据MIL-STD-105E正常单次二级水准随机抽样,MAJ=0.65,MIN=1.0二、检验项目及相关质量要求1、首先确定BOM单要求的规格、容量、误差、耐压值、耐温值及误差值等是否与来料一致。
2、电容量的实际测量值(用LCR METER测量)必须在标准值±误差值范围以内。
3、电容引出脚之间的间距必须与技术资料要求一致。
4、电容商标必须清晰和完整,油漆必须鲜明,不能有污染,外形必须完整无损。
5、电容引出脚中铅锡合金电镀层颜色明亮一致不能出现斑点等氧化现迹象。
6、电容引出脚间间距为1MM以下,其带状排列必须整齐划一,不能有任何参差不齐的现象。
7、测量容量(插件电容)是否在误差范围内,确定种类、规格是否正确。
A、电解电容曾出现过波峰焊后掉皮和包错皮的现象(4.7UF/16V 包错为47UF/16V的皮),绦纶电容规格脚距来错,来错规格导致体积过大影响装配,B、常见的插件电容有电解电容、瓷片电容、金属膜电容、安规电容、绦纶电容、独石电容,检查插件电容的重点在于它的种类和规格,检查前确定应使用哪一种,然后按要求测量规格(包括体积、脚距)有条件下要试装。
8、参照BOM单用卡尺测量其直径、高度。
9、参照BOM单用稳压电源按耐值正向耐压电测。
10、用电容测试仪器测量其容量。
11、电容的正负极标识不能反、标识的容量要与实际容量一致。
贴片电容:12、检查外观注意是否有氧化和破损现象。
13、用电容表测量其容量是否与在误差范围之内。
14、对特别要求客户,如康创还应注意颜色、形状是否有不一样或与上次不一样的,如有不一样的应及时通知客户确认后使用,并通告相关人员跟进。
A、贴片电容检查时应特别注意颜色、形状(体积、厚薄度),若在同一次来料中发现有几种颜色、形状的,或者与上次来料不符合的,要马上以书面形式联络客户,确认好后才可以使用,对每次来料与上次来料颜色、形状有差别的都必须留样品,以便下次对照,方便生产及检查。
cbb电容标准
cbb电容标准CBB电容是一种常见的电容器件,它采用了聚丙烯薄膜作为介质,具有高温稳定性、低损耗和优异的绝缘性能。
CBB电容广泛应用于各种电子设备和电路中,例如电源滤波、交流电机起动和运行、音频放大器等。
CBB电容的标准可参考以下几个方面:1. 容值和精度:CBB电容的容值通常以微法(uF)为单位,例如0.1uF、1uF、10uF等。
容值的精度通常表达为百分比的误差范围,常见的精度有±5%、±10%等。
这个标准表明了CBB电容的容值的可接受误差范围,如±5%精度表示该电容器的实际容值可在标称容值上下浮动5%。
2. 工作电压:CBB电容的工作电压是指电容器可以承受的最大电压值,常见的工作电压范围包括50V、100V、250V、400V等。
工作电压是选择CBB电容时需要特别关注的指标,应根据电路中的工作电压要求选择合适的工作电压等级。
3. 尺寸和外观:CBB电容的尺寸和外观对于电路设计和安装非常重要。
一般来说,CBB电容的尺寸与其容值和工作电压有关,通常越大的容值和工作电压所需的电容器尺寸也越大。
而外观方面,CBB电容通常采用圆柱形结构,两端带有引线,以便与电路连接。
4. 使用温度范围:CBB电容有着良好的高温稳定性,一般可以在-40℃至+105℃的温度范围内正常工作。
这个标准使CBB电容适合应用于各种温度环境中,例如汽车电子、工业控制装置等。
总之,CBB电容的标准包括容值和精度、工作电压、尺寸和外观,以及使用温度范围等重要参数。
这些标准有助于工程师和设计人员在选择和应用CBB电容时做出准确和合理的决策,并确保电路的正常运行和性能要求的满足。
电容检验标准
1、适用范围Applicable Scope本规定适用于单相异步电机运转电容(C B B电容)。
This criterion applies to the running capacitor (CBB) put on the single phase asynchronous motor manufactured by Guangdong Lingxiao Pump Industry Co., ltd.2、执行标准Standard电容器必须符合IEC60252和GB3667有效版本的要求。
Capacitor must comply with the latest version IEC60252&GB3667.3、电容运行等级分级Class of Operation根据IEC60252标准,电容在额定负荷、额定电压、规定温度和额定频率下的最短总寿命分为下列四个等级。
As stipulated in IEC60252, the minimum total life for which the capacitor has been designed at rated duty, voltage, temperature and frequency is:A级(A class)—30000h Class A-30 000hB级(B class)—10000h Class B-10 000hC级(C class)—3000h Class C- 3 000hD级(D class)—1000h Class D- 1 000h4、检验、试验设备Inspection and Testing instruments电容耐久试验综合测试系统、电容冲击测试台、500V直流充击测试台、电容测试仪、20KV A变压器、湿热箱、高压锅等。
The inspection and testing instrument listed as: Capacitor endurance general testing system, capacitor impact testing station, 500V direct current impact testing station,capacitor testing instrument, 20KV A transformer, damp heat testing case, pressure cooker etc.5、检验流程Inspection Procedure5.1.CBB60、CBB61电容检验流程CBB60, CBB61 capacitor inspection procedure:电容整体质量评估外观、标志、认证塑料外壳阻燃性(仅适用于塑料外壳)外型尺寸及引线长度线耳冲压质量或插接端子质量检验电容值和损耗角正切值测量两极间耐压试验极间与外煮水试验冲击试验耐久试验解剖检验、分析出检验报告Capacitor holistic quality evaluation→visual, marks, certification→fire resistance of the plastic shell (only applicable to plastic shell)→dimension and lead length →termination pressing quality or plug termination quality inspection→measure of capacitor value and tangent of loss angle value→voltage duration test between 2 poles→voltage duration test between pole and shell(only applicable to metal shell)→water cooking testimpact test ,duration test →anatomic inspection and analysis→testing report5.2.CBB65电容检验流程CBB65 capacitor inspection procedure:电容整体质量评估外观、标志、认证外型尺寸线耳冲压质量或插接端子质量电容值和损耗角正切值测量两极间耐压试验冲击试验耐久试验解剖检验、分析出检验报告Capacitor holistic quality evaluation→visual, marks, certification→dimension termination pressing quality→measure of capacitor value and tangent of loss angle value voltage duration test between 2 poles→voltage duration test between pole and shell(only applicable to metal shell)→ impact testduration test →anatomic inspection and analysis→testing report6、检验、试验要求Inspection and Testing Requirements6.1.电容试验前整体质量评估Capacitor holistic quality evaluation before test6.1.1.电容器环氧树脂封灌要求(限于CBB60、CBB61电容)Epoxy resin requirements (it is only limited to CBB60, CBB61)6.1.2.电容器的整个芯子都必须有环氧树脂密封,灌封要求按附图1示例。
电容类检验规范
2
审核/日期
1
批准/日期
修订次数
修订
日期
审核
日期
一般抽样II级
√
2
外观
/
目视
2.1
字符不清晰
一般抽样II级
√
比对样品
参照《承认书》
2.2
字符错误
√
2.3
本体缺损、变形
√
2.4
引脚氧化、发黑
√
2.5
物料编码或标签信息错误
√
2.6
极性电容正负极反(针对电解电容、钽电容)
√
3
规格
卡尺
测量
尺寸
3.1
尺寸超出公差范围
特殊抽样S-3
√
参考《承认书》
打“*”号为重点尺寸
电容类检验规范
版本
更改类型
生效日期
更改内容
会签部门:
品质:工程:
采购:业务:
PIE:体系:
生产:PMC:
制作:
审核:
批准:
XX有限公司
文件编号
版 本
电容类检验规范
页码
发行日期
1、检验内容与判定:
项次
检查项目
使用工具
检验方法
检验情况
缺陷类别
备 注
项次
缺点描述
抽样计划
CR
MAJ
MIN
1
包装
/
目视
1.1
未按要求安全、定量包装、混料
5.2
漏电流超出规格范围
√
5.3
高压不过
特殊抽样S-1
√
6
环保
XRF扫描仪
测试
6.1
CBB电容的检测方法
CBB电容的检测方法CBB电容的组成原理其实比较简单,就是两块平行带点板,中间绝缘介质组成芯子,两块板各有一个引出,即两电极。
CBB电容是聚丙烯电容,其主要特点性能与聚苯相似但体积小,稳定性略差。
CBB电容无极性,体积小,容量大,稳定性比较好,可靠性高和自愈性强。
绝缘阻抗很高,频率特性优异,而且介质损失很小。
能抗高电压、大电流冲击,具有损耗小,电性能优良,绝缘电阻高,但是温度系数大。
CBB电容被大量使用在谐振电路、旁路电路以及高频高电压的电路上。
像仪器、仪表、电视机及家用电器线路中,可作直流脉动和交流降压用,特别适用于各种类型的电子整流器和节能灯线路中,还可以各类接触器触点的高压电势吸收线路。
原理无极性,绝缘阻抗很高,频率特性优异(频率响应宽广)。
由于被广泛使用,我们有必要了解一些常用的CBB电容检测方法一、检测10pF以下的小电容。
10pF以下的固定电容器容量太小,用万用表进行测量,只能定性的检查其是否有漏电,内部短路或击穿现象。
测量时,可选用万用表R×10k挡,用两表笔分别任意接电容的两个引脚,阻值应为无穷大。
若测出阻值(指针向右摆动)为零,则说明电容漏电损坏或内部击穿。
二、检测10pF~0 01uF的CBB电容器是否有充电现象,进而判断其好坏。
万用表选用R×1k挡。
两只三极管的β值均为100以上,且穿透电流要小。
万用表的红和黑表笔分别与复合管的发射极e和集电极c相接。
由于复合三极管的放大作用,把被测电容的充放电过程予以放大,使万用表指针摆幅度加大,从而便于观察。
应注意的是:在测试时,特别是在测较小容量的电容时,要反复调换被测电容引脚接触A、B两点,才能明显地看到万用表指针的摆动。
三、对于0 01uF以上的固定电容,可用万用表的R×10k挡直接测试电容器有无充电过程以及有无内部短路或漏电,并可根据指针向右摆动的幅度大小估计出电容器的容量。
cbb22电容好坏怎样测量
cbb22电容好坏怎样测量
电⼦上⼀些电⼦元器件损坏以后,有些时间我们⽤⾁眼并不容易发现,这个时候就需要使⽤⼀些测量⼯作来检测,对于CBB22电容,我们应该如何检测呢?今天就来详细为⼤家讲解⼀下相关的⽅法。
1、观察CBB22电容外表,看有没有损坏。
如果CBB22电容出现击穿、爆炸的问题,通过外观⼀般都能看出来,如果外观有明显损坏,那就说明CBB22电容已经不能正常⼯作,就需要更换。
2、使⽤万⽤表测试CBB22电容容量。
有些时候,CBB22电容从外观来看没有任何问题,但由于长期使⽤,容量衰减严重,这就⽆法再使⽤,也需要更换,最简单的⽅法,就是使⽤万⽤表来测量电容容量。
具体的测试⽅法如下:
将万⽤表拨到电阻档,再切换到电容测量功能。
把电路上的CBB22电容拆卸下来(必须拆卸下来才能测量出准确的容量)。
使⽤⼀只万⽤表笔将电容两端短接、放电(只要想办法接两个电容的脚连接⼀下,把电容内的电放掉即可,不然测量的结果可能不准确)。
万⽤表红⾊表笔、⿊⾊表各接电容⼀个脚。
(CBB22电容不分正负极)
待电容值读数稳定后,对⽐它与所标的电容是否相符。
如果偏差较⼤,说明电容损坏。
使⽤上⾯的⽅法,就可以轻松检测出来CBB22电容有没有损坏。
CBB电容,无极性电容测试作业指导书
CBB电容,无极性电容测试作业指导书1.CBB电容,无极性电容测试项目1.1.无极性电容值测试2.测试内容2.1CBB电容,无极性电容测试2.1.1参照标准:GJB360A-96 电子及电气元件试验方法。
2.1.2使用设备名称/型号:晶体管测试仪型号:JL295-3;2.1.3 CBB电容,无极性电容击穿电压值测试方法:1)操作方法:以0.01μF/63V~400VCBB电容值为例:基准温度:+25℃,采用晶体管测试仪VBR/100V 挡(附图);容量仪器极性插孔VBR/100V挡位第一步将CBB电容或无极性电容两脚(无极性)任意插入仪器两个孔内;第二步按下仪器VBR/100V挡这时仪表指针即显示出电容瞬间击穿电压值,一般0.01μF/400VCBB 电容击穿电压值约在1500-2000V左右,但是不同生产厂家的CBB电容瞬间击穿电压值高低均不一样,总之无极性电容瞬间击穿电压值只要大于电容样品上标定耐压值的2.5-3倍值即为合格。
2.1.4无极性电容值测试方法:A)电感电容测试仪:型号: DY6243;B)参照标准:GJB360A-96 电子及电气元件试验方法:C)操作方法:以0.01μF/400VCBB电容值为例:基准温度:+25℃,计划采用电感电容测试仪2 00 nF挡;第一步将CBB电容任意插入仪器夹具两孔中,这时仪器液晶显示屏上即显示出CBB电容值,根据电容值对照国家标准误差范围±5%,是否符合电容0.01μF容值在误差内即为合格品。
2.1.5无极性电容高/低温测试方法:1)参照标准:GJB360A-96 电子及电气元件试验方法第98页(有两个测试温度系列)。
2)温度系列为+25, -25, +55℃。
温度误差为±1℃。
2.1.6无极性电容高/低温测试温度范围选取方法:方法1:根据本公司产品企业标准选择高、低温试验等级。
方法2:根据公司产品是否通过了UL、CE、GS、TUV、3C认证来选择高低温度等级。
CBB电容器检验标准作业指导书
批准CBB电容器检验标准文件编号审核修改状态编制制(修)订日期2011.10.30检验项目检验要求检验工具不良等级抽样方式判定包装1、包装无破损;2、外包装标识清晰、整洁、无错误;3、包装箱上标识型号、数量、生产日期(生产批号)标识。
目视 AGB2828-2003一般II级AQL=1.5外观1、电容器表面必须含有容量、额定电压、容量精度标识;2、电容器表面丝印清晰,无漏印、丝印不清晰;2、电容器表面无变形、破损或露出介质;3、电容器引脚无伤痕、断裂、氧化、松动。
目视 AGB2828-2003一般II级AQL=1.5结构尺寸封装尺寸符合技术要求。
游标卡尺 A N=5 Ac=0 Re=1电容值测量的实际容值符合标称容值允许误差范围内。
LCR数字电桥 A N=10 Ac=0 Re=1耐压性1、引线和引线之间:给电容两端施加2倍额定电压之DC电压,历时1min (电容实际技术要求),电容无被击穿、短路、爆裂等现象;2、引线和壳体之间:电容器引出端与外壳之间应能承受2倍额定电压(最低为400VDC),历时1min,电容无被击穿、短路、爆裂等现象。
耐压测试仪 A N=5Ac=0Re=1绝缘电阻测试条件:额定电压<100V,施加10VDC/60S;额定电压≥100V,施加100VDC/60S;1、当电容量C R≤0.1μF时,引线间绝缘电阻≥100000MΩ;2、当电容量C R>0.1μF时,引线间绝缘电阻≥100000*C R MΩ;引线与外壳之间的绝缘电阻大于10000MΩ。
绝缘测试仪 A N=5Ac=0Re=1损耗角正切值测试1、对于C R≤1000PF(25℃,100KHz),损耗角正切≤0.1%;2、对于1000PF≤C R<0.1μF(25℃,100KHz),损耗角正切≤0.05%;3、对于C R>0.1μF(25℃,100KHz),损耗角正切≤0.1%。
LCR数字电桥 A N=5Ac=0Re=1高温老化1、常温额定电压下,保持12分钟,漏电流﹛当U R≤100V时;I≤0.01CV或3μA(取大者);当U R>100V时;I≤0.03CV+10μA﹜;2、高温85℃、额定电压下,连续24小时,检测其漏电流波动情况,每5分钟记录一次数据,要求老化过程中漏电流无大的波动,且小于10倍初始极限值;3、恢复至常温,保持12分钟,监测漏电流、损耗角、绝缘电阻符合常温下标准。
电容检验标准
4
可焊性
炉温在250-270℃状态下,浸锡时间:1.5~3S,观察引脚吃锡率>95%以上。
浸锡
试验
经浸锡试验后,吃锡不良(吃锡率小于95%)。
√
电容检验标准
文件名称
电容检验标准
文件编号
页码
2 of 2
版本
A / 0
序号
检验
项目
接收标准
检验工具及
方法
缺陷描述
缺陷等级
致命(CR)
严重(MA)
轻微(MI)
参照标准
1、GB / T2828.1-2003逐批检查计数抽样及抽样表。
序号
检验
项目
接收标准
检验
方法及工具
缺陷描述
缺陷等级
致命(CR)
严重(MA)
轻微(MI)
1
包装
包装必须有标识,外标识与实物一致。
目视
外标识与实物不一致。
√
包装箱不能有破损、脏污现象。
包装箱有破损、脏污现象。
√
同一个规格型号不能有混料现象。
1)损耗角正切值不大于原规定值2倍;
2)容量变化不超过30%。
不符合要求。
√
8
密封和加热试验
将未通电的电容器放置于烘箱(需分散),在85℃状态下恒温烘烤1小时,观察试验期间,电容不得出现浸渍剂或填充料泄漏现象,电容器也不得成为开路,试验后重新测试电容器的容量、损耗角正切值符合原规定要求。
不符合要求。
√
备注
1、本检验标准未尽项目,需检验时可参照行业标准、国标或工程技术文件要求。当检验标准的检验项目在技术要求中未作规定时,可不作检验要求。
2、高温储存试验、耐久性、密封和加热试验,按5批次作一次抽取实验(数量:3-5pcs)。
cbb电容选型重点考查哪些参数
cbb电容选型重点考查哪些参数
CBB电容的型号还是极多的,以CBB22电容为例,就算是同一个容量、电压、尺寸都可以做出来很多很多种,所以具体如何选型,需要通过很多参数来最终确定,cbb电容选型重点考查哪些参数?下面小编就来重点为大家普及一些这方面的知识。
1、电容容量大小。
这个是最重要的,电路上需要多大容量的电容,这个最先需要确认的参数。
2、电容的容量误差。
不要指望实际购买的电容容值没有一点点误差,一般CBB电容误差有J档±5%、K档±10%的误差。
要看一下你电路上可以接触的容量误差范围。
3、电容的额定电压。
以CBB22电容为例,它的额定电压一般为100/250/400/450/630VDC,在确定你所用电路中的额定电压值是多少。
4、电容材质。
比如普通的CBB电容,使用聚丙烯薄膜。
耐高压高频要用CBB13/CBB81双面金属膜。
5、电容的脚距。
就是电路板上给电容两脚预留的距离,脚距太大、太小,都会导致无法安装。
6、电容的尺寸。
有一些电路板设计的很紧凑,如果电容尺寸太大,可能导致无法安装。
聚酯薄膜电容器检验规范
编制日期Байду номын сангаас
审核日期
批准日期
修订记录
修订状态
修改内容
修改人
批准人
日期
1、主题:本标准规定了聚酯薄膜电容器的检验要求和检验方法。
2、检验项目和检验方法
2.1外观和标志
2.1.1技术要求:外包装箱应标明产品编号、型号、生产日期、数量、制造商名称等;电容器表面不应有锈蚀、裂痕、压痕和其它机械性损伤;标志应清晰、正确、牢固。
b、检验方法:用LCR表进行测量。
2.3.3耐焊接热
a、技术要求:无可见损伤、标志清楚;容量变化小于规格书所要求。
b、检验方法:浸入温度为260±5℃的熔锡内,浸入时间5±0.5秒。
2.4可焊性
a、技术要求:导线上沾锡面积≥90%。
b、检验方法:导线须浸入助焊剂后再浸入230±5℃的熔锡内,浸入时间2±0.5秒。
3、检验规则
交收检验。按GB2828—87《逐批检查计数抽样程序及抽样表》中一次正常抽样方案进行,检查水平Ⅱ级。
合格质量水平AQL值分别如下:
重缺陷:0.065轻缺陷:0.65
4、缺陷分类
4.1重缺陷:错料、混料,电容裂、变形,电性能不符合,引脚不上锡。
4.2轻缺陷:尺寸略超差,但不影响使用;外观轻微缺陷,但不影响使用。
2.1.2检验方法:目测法。
2.2外形尺寸
2.2.1技术要求:符合规格书的规定尺寸。
2.2.2检验方法:用游标卡尺测量。
2.3电气性能
2.3.1静电容量
a、技术要求:符合产品规格书规定的容值和容许偏差。
b、检验方法:用LCR表进行测量。
2.3.2损耗角正切值
a、技术要求:符合产品规格书规定的损耗角正切值。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
CR/3-5pcs CR/5-10pcs
将检验结果记录在《产品检验报告单》中。经抽样检查、判定为合格的整批接收;检验中发现 记录与判定 的不合格品,应及时做好不合格品标识,作隔离以《产品检验报告单》的形式交由上级处理,
最终判定不可接收产品报采购通知供应商退货处理。
编制:品质部
审批:
核准:
检验方式和器 具
目测
AQL MA/1.0
标识附着力 标识清晰,用浸酒精的棉球擦拭三次后无变化
有机溶剂 MI/3-5PCS
外观检验
外观要求表面无锈蚀,无损伤,布线整齐,胶皮完整,引脚紧固,无断 脚,型号、电压、电流等标识清晰。
目测
MI/2.5
尺寸
根据规格书或样品检查外形尺寸,规格尺寸、外形、引脚符合公司技术 要求。
1、目的
浙江明帅照明科技有限公司 ZheJiangMingShuai Lighting Co.,Ltd
CBB电容检验标准
产品名称:CBB 版本 发行日期 页码 编制部门
MSPZ-CBBDR-01 1
2016/1/10 第1页 共1页
品管部
2、适用范围 适用本公司所有CBB电容类产品检验之标准
验
为开路,试验后重新测试电容器,容量、损耗角正切值符合原规定要求 数字电桥
。
注意事项
1、检验时须戴干净手套。 2、物料送检时要及时检验。 3、所照参样板必须为合格样板。 4、引脚表面有氧化发黑时需做可焊性试验进行进一步确认。 5、电气性能测试按供应商规格书检验。 6、除了特殊要求外,所有检测在常温常压内进行。 7、所有检验过程中使用器具必需在有效校正期内。
耐压仪
CR/3-5pcs
可焊性
将物料引脚渗有松香内一秒,立即渗入温度为250℃±5℃的锡炉内3-5 秒,上锡面积应不小于浸锡面积的90%,且无针孔和沙眼
目测、锡炉
将未通电的电容器放置于烘箱(需分散),在85℃状态下恒温烘烤1h,观
密封和加热试 察试验期间,电容不得出现浸渍剂或填充料泄漏现象,电容器也不得成 电烤箱、LCR
游标卡尺
CR/3-5pcs
电气特性
1、电容量:在1KHZ条件下测试,容量在规定偏差范围内 2、损耗角正切值:在1KHZ条件下测试损耗角正切值符合承认书要求。
LCR数 字电桥
CR/3-5pcs CR/3-5pcs
3、耐压:电容器在室温下承受施加于引脚间的,其值为2UR(额定电压), 历时60S的直流电压,漏电流设定1MA无超漏击穿现象
3、抽样计划
4、允收水准 (AQL) 5、检验项目
项目
包装检验
按 GB2828-2003中正常检验一次抽样方案进 行,检查水平II级。如需要性能测试,按每 批以3-5pcs进行,零缺陷接收标准。 严重缺陷(CR):0.01;主要缺陷(MA): 1.0;次要缺陷(MI):2.5
检验内容及要求
根据规格书来料检验单核对要求包装整齐,型号、数量正确,标识清楚,搬运 中不会损坏。