Replace faulty hardware
Restart RBS/Check boards if need to be replaced. Lock MO. Not using ethernet switch yet Replace faulty board Check hardware/cable Check RfCable Restart RBS/Replace faulty RU Bring the unavailable synch ref up/Check Synchronization Reference Cable (SRC)/Restart RBS Restart Check synchref parameter. Restart RBS Restart RBS/Check CBU Check Synchronization Reference Cable (SRC). Restart RBS Restart RBS
TrDeviceSet_GeneralHwError Carrier_SignalNotReceivedWithinTi me Ethernet wk.baidu.comwitch Port Fault Loss of Switch Redundancy Plane B OpticalInterfaceLink_OpticalInterfac eLinkFailure DigitalCable_Disconnected TpaDevice_AmplificationError
Set a new password, using the shell command passwd Load the new valid LKF received from Ericsson
Load the new valid LKF received from Ericsson
Load the new valid LKF received from Ericsson Check Tx link Unlock NBAPCommon at RNC Restart/replace faulty board. Check Tx.
Issues HW Synch License Link
General actions Check HW/cable Restart RBS Load valid license Check Tx/HW
Connected RBS in BJCU Network
Action Replace faulty hardware/cable Check configuration/hardware Check fan & cable
Hardware/cable fault RfCable disconnected RU fault/software error All but one of the defined Loss of Synch Reference Synchronization references are Redundancy unavailable The system or radio clock cannot track a Loss of Tracking synchronization reference TimDevice_RadioClockIsNotStable CBU may be faulty System Clock Quality Degradation Synch Reference Path HW Fault Synchronization references not available Loss of signal on a supervised synchronization reference
Summary of Alarms for All Connected RBS in BJCU Network
Alarm AuxPlugInUnit_PiuConnectionLost Plug-In Unit General Problem FcuDeviceGroup_NumberOfHwEnti tiesMismatch Cause No supervision on PlugInUnit Configuration/hardware fault A faulty or disconnected fan unit cable A component is faulty and must be replaced. Problem in the communication with the hardware related to the carrier. FU/RRU/RFIR/TX board may be faulty. No SFP Module Installed Fault in the redundant switch plane in a switch module
No password set for user access via Telnet, SSH, FTP, SFTP or a serial port No valid License Key File (LKF) is found License Key File Fault in the node AISG/3GPP Remote Electrical Tilt Unit (ARETU) is configured without a valid NodeBFunction_StandardizedRetLi license. censeNotValid AISG/3GPP Tower Mounted Amplifier (ATMA) is configured without a valid NodeBFunction_StandardizedTmaL license. icenseNotValid IMA Link Transmit Unusable at Far End Remote Tx node error Password File Fault NbapCommon_Layer3SetupFailure NBAPCommon is locked at RNC PDH Loss of Signal ET board cannot detect any signal Summary