voith伺服阀说明书-英文版

合集下载
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Way Valve

Type WSR-D16112 Type WSR-D16118 INSTRUCTION MANUAL Version 3.0

Should you have any questions concerning the way valve, please contact the Service Department of the product group Electronic Drive Systems, Voith Turbo GmbH & Co. KG, Crailsheim, indicating

article number and serial number of the way valve.

Voith Turbo GmbH & Co. KG

P.O. Box 15 55

D-74555 Crailsheim

Switchboard: ++49 – 7951 / 32 - 0

Fax: ++49 – 7951 / 32 - 500

Service department of product group

Electronic Drive Systems

Direct dial: ++49 – 7951 / 32 - 470

Direct fax: ++49 – 7951 / 32 - 605

turcon@

E-mail:

Address for goods supplied:

Voith Turbo GmbH & Co. KG

Dept. aie

Voithstr. 1

D-74564 Crailsheim

This instruction manual describes the technical condition of the

way valve for deliveries from June 2004.

Any modifications following the delivery are not considered in this operating manual.

Voith Turbo GmbH & Co. KG 2004

This instruction manual is protected by copyright.

It may not be reproduced or translated in any form or by any

means (mechanical or electronic) or submitted to

third parties, without the publisher’s written approval.

amendment: 04/10, aiet-Ochs

Order No.: 3.626-018901 en

Version: 3.00

Printed in Germany

Contents

data

1. Technical

Information

2. Safety

2.1 Definition of notes and symbols

2.2 Proper use

2.3 Important notes

2.4 Warranty

3. Functional Description

3.1 Design

3.2 Operating characteristics

4. Packing, Storage and Transport

5. Installation

5.1 Mounting

5.2 Hydraulic connection

5.3 Electric connection

6. Commissioning

6.1 Test run

6.2 Parameter setting

6.2.1 Adjustment of the control piston hydraulic center

6.2.2 Stroke

adjustment

6.2.3 Adjustment of proportional gain

7. Operation

manual operation knob

with

7.1 Operation

7.2 Operation wit set signal

7.3 Trouble shooting and remedial action

8. Maintenance and Repair

9. Shutdown

10. Annex

1. Technical Data

Ambient conditions:

temperature for storage -40 °C ... +90 °C

Ambient

temperature: -20

°C ... +85 °C

Ambient

Protection IP 65 to EN 60529

suitable for internal installation in industrial air

data:

Electric

VDC

24

Supply

voltage

Power consumption approx. 0.8 A

max. 3 A, for t < 1 sec Setpoint input w = 4...20 mA

input resistor 100 Ohm

with

circuit.

suppressor

Actual value input 20..4 mA

input resistor 332 Ohm

Actual value remote indication 4..20 mA

resistor max. 400 Ohm.

Electric connection see Chapter 10

Hydraulic data:

Input pressure P 90 bar

Input pressure P max 120 bar

Flow rate line at ∆P = 20 bar 45 l/min (P→A,B→T)

90 l/min (max)

Pressure fluid mineral oil or hydraulic oil

Viscosity pressure fluid ISO VG 32... ISO VG 48 to

51519

DIN

Temperature pressure fluid: +10 °C...+70 °C

Oil purity recommended purity class:

to NAS1638 class 7

to ISO4406 class -/16/13

Leakage ≤ 5 l/min

Mechanical data:

Dimensions, fitting see chapter 10

Hydraulic connection see chapter 10

Mounting position see chapter 10

Sealing material FPM and NBR

kg

15

Weight approx.